1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.Read the user’s manual carefully before using this product. The user’s manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of January 2016 but subject to change without notice. All rights reserved PCc
DC Inverter Control 50 Hz
Split Type Air Conditioners
Urusara 7
FTKJ and FTXJ Series
FTKV and FTXV Series
FTKC, FTXM and FTHM Series
Cooling Only and Heat Pump
Urusara 7
FTKJ and FTXJ Series
PCRVN1447Baprv
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.Read the user’s manual carefully before using this product. The user’s manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
All rights reserved PCc
Split Type Air Conditioners
Urusara 7
FTKJ and FTXJ Series
Specifications, designs and other content appearing in this brochure are current as of January 2016 but subject to change without notice.
DC Inverter Control 50 Hz
Urusara 7
FTKJ and FTXJ Series
FTKV and FTXV Series
FTKC, FTXM and FTHM Series
Cooling Only and Heat Pump
1 2
Lineup of DC Inverter Air Conditio ners with R-32 RefrigerantDaikin is the sole manufacturer to produce both air conditioning equipment and refrigerants worldwide. Our cutting-edge technologies and use of advanced R-32 refrigerant provide enhanced comfort while reducing the impact on climate change.
Urusara 7
FTKJ and FTXJ Series
FTKV Series
2.5 kW Class
FTXZ25NVMV
FTKJ25NVMVS (silver) and FTXJ25NVMVS (silver)
FTKJ25NVMVW (white) and FTXJ25NVMVW (white)
FTKV25NVMV
FTKC25QVMV
2.0 kW ClassProduct name 3.5 kW Class
FTXZ35NVMV
FTKJ35NVMVS (silver) and FTXJ35NVMVS (silver)
FTKJ35NVMVW (white) and FTXJ35NVMVW (white)
FTKV35NVMV
FTKC35QVMV
Daikin Mobile Controller is not available Daikin Mobile Controller is not available Daikin Mobile Controller is not available
5.0 kW Class
FTXZ50NVMV
FTKJ50NVMVS (silver) and FTXJ50NVMVS (silver)
FTKJ50NVMVW (white) and FTXJ50NVMVW (white)
FTKV50NVMV
FTKC50QVMV
6.0 kW Class
FTKC60QVMV FTKC71QVMV
FTXM25HVMVFTXM20HVMV FTXM35HVMV FTHM50HVMV FTHM60HVMV
FTKC Series
FTXV Series
FTXM and FTHM Series
FTKV60NVMV
7.1 kW Class
FTKV71NVMV
FTXV25QVMV FTXV35QVMV FTXV50QVMV FTXV60QVMV FTXV71QVMV
FTHM71HVMV
NEW NEW NEW
NEW
NEW
NEW NEW NEW NEW NEW
NEW NEW NEW
NEW
indicates a model with a new design.NEW indicates a model with a new capacity class.NEW
Cooling Only
Cooling Only
Cooling Only
Heat Pump
Heat Pump
Heat Pump
Heat Pump
A New Kind of Cool
This is for residential-use wall-mounted type air conditioners as of November 2012, when Daikin launched Urusara 7 in the Japanese market.In January 2013, the 4.0 to 7.1 kW class models for the Japanese market received the Minister’s Prize from Japan’s Ministry of Economy, Trade and Industry in the Fiscal 2012 Grand Prizes for Excellence in Energy Efficiency and Conservation.As of 1999, when Daikin launched Ururu Sarara in the Japanese residential-use air conditioner market.
Notes: 1.2.
3.
3 4
Urusara 7 puts the latest Japanese air conditioning technology at your fingertips, offering a unique, total comfort experience for any lifestyle. Powerful year-round cooling and dehumidifying are just the beginning.
Urusara 7 is also the world’s first air conditioner to use next-generation R-32 refrigerant1. Along with its many energy-saving features, this higher performance refrigerant gives Urusara 7 unrivalled energy efficiency2.
Urusara 7
Features•
•
•
•
•
•
•
Redesigned air intake and heat exchanger
World-first3 humidity control technology
Precision circulation airflow
Reliable streamer discharge air purification
Convenient automatic filter cleaning system
Innovative design with Japanese aesthetic
Remote control via smartphone (optional adaptor)
Category: Product Design 2013
Form. Function. Design.
5 6
Sleek Europiean style of FTKJ and FTXJ series proves once again that design is everything. Yet this elegant body also houses cutting-edge smart technology which provides outstanding comfort and performance in any situation.
The series also delivers Daikin’s well-known energy efficiency, thanks to features such as its redesigned swing compressors. This versatile system truly is a total solution for designers, architects and home-owners alike.
FTKJ and FTXJ Series
Features•
•
•
•
•
Energy-saving COP of 3.59 to 4.81 for the FTKJ series
Stylish finish in eye-pleasing colours
Wide selection of comfort technologies
Whisper quiet sound level
Remote control via smartphone (optional adaptor)
White Silver
Category: Product Design 2014
7 8
Contents
2.45 (0.6-3.9) 4.95 (0.6-5.8)3.45 (0.6-5.3)
8,400 (2,000-13,300) 16,900 (2,000-19,800)11,800 (2,000-18,100)Capacity
Power consumption
Dimensions (H × W × D)
Cooling
Cooling
Heating
Rated (Min.-Max.)
kW
Btu/h
3.6 (0.6-7.5) 6.3 (0.6-9.4)5.0 (0.6-9.0)
12,300 (2,000-25,600) 21,500 (2,000-32,100)17,100 (2,000-30,700)
Rated (Min.-Max.)
kW
Btu/h
Heating
430 (110-880) 1,150 (110-1,600)680 (110-1,330)
620 (100-2,010) 1,410 (100-2,640)1,000 (100-2,530)
Rated (Min.-Max.)
Cooling
Cooling
Heating
Rated (Min.-Max.)
Rated (Min.-Max.)
Heating
Rated (Min.-Max.)
W
295 × 798 × 370mm
See the FTKJ and FTXJ series catalogue for details.
See the Urusara 7 catalogue for details.
FTXZ25
RXZ25
FTXZ35
RXZ35
FTXZ50
RXZ50
Indoor unit
Outdoor unit
Model name
FTXZ25 FTXZ35 FTXZ50Indoor unit
Dimensions (H × W × D) 595 × 795 × 300mm
RXZ25 RXZ35 RXZ50Outdoor unit
2.45 (0.6-3.9) 4.95 (0.6-5.8)3.45 (0.6-5.3)Cooling capacity
Power consumption
Dimensions (H × W × D)
Rated (Min.-Max.)kW
Btu/h
Rated W
303 x 998 x 212
550 x 765 x 285 735 x 825 x 300
mm
FTKJ25 (silver)
RKJ25
FTKJ35 (silver)
RKJ35
FTKJ50 (silver)
FTKJ25 (white) FTKJ35 (white) FTKJ50 (white)
FTKJ25 (silver) FTKJ35 (silver) FTKJ50 (silver)
FTKJ25 (white)
2.5 (1.2-3.4)
8,500 (4,100-11,600)
520
3.5 (1.3-4.1)
11,900 (4,400-14,000)
855
5.2 (1.7-5.5)
17,700 (5,800-18,800)
1,450
FTKJ35 (white) FTKJ50 (white)
RKJ50
RKJ25 RKJ35 RKJ50
Indoor unit
Outdoor unit
Model name
Indoor unit
Dimensions (H × W × D) mm
Outdoor unit
Urusara 7
FTKJ Series
Heat Pump Heat Pump
Cooling Only
FTXZ25/35/50
FTKJ25/35/50 (silver)FTKJ25/35/50 (white)
See the FTKJ and FTXJ series catalogue for details.
2.45 (0.6-3.9) 4.95 (0.6-5.8)3.45 (0.6-5.3)
Capacity
Power consumption
Dimensions (H × W × D)
kW
Btu/h
kW
Btu/h
W
303 x 998 x 212
550 x 765 x 285 735 x 825 x 300
mm
FTXJ25 (silver)
RXJ25
FTXJ35 (silver)
RXJ35
FTXJ50 (silver)
FTXJ25 (white) FTXJ35 (white) FTXJ50 (white)
FTXJ25 (silver) FTXJ35 (silver) FTXJ50 (silver)
FTXJ25 (white)
2.5 (0.9-3.3)
8,500 (3,100-11,300)
3.2 (0.9-4.7)
10,900 (3,100-16,000)
540
700
3.5 (0.9-4.1)
11,900 (3,100-14,000)
4.0 (0.9-5.1)
13,600 (3,100-17,400)
920
990
5.0 (1.4-5.5)
17,100 (4,800-18,800)
5.8 (1.1-7.0)
19,800 (3,800-23,900)
1,470
1,590
FTXJ35 (white) FTXJ50 (white)
RXJ50
RXJ25 RXJ35 RXJ50
Indoor unit
Outdoor unit
Model name
Indoor unit
Dimensions (H × W × D) mm
Outdoor unit
FTXJ SeriesFTXJ25/35/50 (silver)FTXJ25/35/50 (white)
It’s Time for DC Inverter P 9
FTKV Series P 11
FTXV Series P 12
FTKC Series P 13
FTXM and FTHM Series P 14
Reuse of Existing Piping P 15
Next-Generation R-32 Refrigerant P 16
Inverter Air Conditioners Reduce Electricity Consumption P 17
All Models Feature High Energy Ratings P 19
Less Wasted Energy with Infrared Sensors P 21
Choice of Wide Range of Airflow Patterns P 23
Quiet Nights in Your Neighbourhood P 25
Set and Forget On/Off Operation P 27
Photocatalytic Air Purifying P 29
Remote Control via Smartphone P 31
Function List P 33
Functions P 35
Wireless Remote Controller P 37
Specifications P 39
Options P 43
It’s Time for DC Inverter
9 10
Inverter air conditioners are well known for their precise control. In fact, their outstanding efficiency can cut energy bills compared to non-inverter models. This precision also means greater comfort, plus full power at the touch of a button.
With its strong environmental commitment, Daikin has been using its market-leading position to promote inverter systems worldwide. DC Inverter models feature advanced DC motors. These motors use high-power magnets to generate rotation, giving them greater efficiency than AC motors.
FTKC, FTXM and FTHM SeriesFTKV and FTXV Series
Features•
•
•
•
•
Inverter air conditioners with high energy rating
Less wasted and comfortable Two-Area Intelligent Eye
Greater convenience with weekly scheduling
Titanium Apatite Photocatalytic Air-Purifying Filter
Remote control via smartphone (optional adaptor)
FTKV25/35
FTKC25/35
The FTKC, FTXM and FTHM series feature Daikin’s new smile curve design for the front panel. The smile curve creates a stylish, modern appearance which blends easily with any interior decor.
Smile Curve
FTXV25/35
FTXM20/25/35
Heating Capacity Rated(Min.-Max.)
kWBtu/h
3.7 (0.9-5.3)12,600 (3,100-18,100)
3.5 kW Class FTXV35QVMV / RXV35QVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
3.5 (0.9-4.2)11,900 (3,100-14,300)
11 12
FTKV Series Cooling Only
FTXV Series
2.5 kW Class FTKV25NVMV / RKV25NVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
2.5 (1.2-3.4)8,500 (4,100-11,600)
3.5 kW Class FTKV35NVMV / RKV35NVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
3.5 (1.3-4.1)11,900 (4,400-14,000)
FTKV25/35NVMV
RKV25/35NVMV
FTKV50/60NVMV
RKV50/60NVMV
5.0 kW Class FTKV50NVMV / RKV50NVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
5.2 (1.7-6.0)17,700 (5,800-20,500)
6.0 kW Class FTKV60NVMV / RKV60NVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
6.0 (1.9-7.0)20,500 (6,500-23,900)
FTXV50/60/71QVMV
RXV50/60/71QVMV
7.1 kW Class FTKV71NVMV / RKV71NVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
7.1 (2.3-8.9)24,200 (7,800-30,400)
FTKV71NVMV
RKV71NVMV
Heat Pump
2.5 kW Class FTXV25QVMV / RXV25QVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
2.5 (0.9-3.7)8,500 (3,100-12,600)
Heating Capacity Rated(Min.-Max.)
kWBtu/h
3.2 (0.9-5.3)10,900 (3,100-18,100)
Heating Capacity Rated(Min.-Max.)
kWBtu/h
7.2 (1.0-8.6)24,600 (3,400-29,300)
6.0 kW Class FTXV60QVMV / RXV60QVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
6.0 (1.1-7.5)20,500 (3,800-25,600)
Heating Capacity Rated(Min.-Max.)
kWBtu/h
8.0 (2.0-10.6)27,300 (6,800-36,200)
7.1 kW Class FTXV71QVMV / RXV71QVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
7.1 (2.0-8.9)24,200 (6,800-30,400)
5.0 kW Class FTXV50QVMV / RXV50QVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
5.0 (1.1-6.7)17,100 (3,800-22,900)
Heating Capacity Rated(Min.-Max.)
kWBtu/h
6.0 (1.0-8.0)20,500 (3,400-27,300)
FTXV25/35QVMV
RXV25/35QVMV
NEW
NEW
indicates a model with a new design.NEW
13 14
FTKC Series
2.5 kW Class FTKC25QVMV / RKC25QVMV
Cooling Capacity Rated(Min.-Max.)
kWBtu/h
2.5 (1.0-3.4)8,500 (3,400-11,600)
3.5 kW Class FTKC35QVMV / RKC35QVMV
Cooling Capacity Rated(Min.-Max.)
kWBtu/h
3.5 (1.3-4.1)11,900 (4,400-14,000)
7.1 kW Class FTKC71QVMV / RKC71QVMV
Cooling Capacity Rated(Min.-Max.)
kWBtu/h
7.1 (2.1-7.5)24,200 (7,200-25,600)
5.0 kW Class FTKC50QVMV / RKC50QVMV
Cooling Capacity Rated(Min.-Max.)
kWBtu/h
5.2 (1.4-6.0)17,700 (4,800-20,500)
6.0 kW Class FTKC60QVMV / RKC60QVMV
Cooling Capacity Rated(Min.-Max.)
kWBtu/h
6.0 (1.4-6.7)20,500 (4,800-22,900)
RKC50/60/71QVMV
FTKC50/60/71QVMV
FTKC25/35QVMV
RKC25/35QVMV
Cooling Only
FTXM and FTHM Series Heat Pump
Heating Capacity Rated(Min.-Max.)
kWBtu/h
2.5 (1.0-3.4)8,500 (3,400-11,600)
2.5 kW Class FTXM25HVMV / RXM25HVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
2.5 (1.0-3.4)8,500 (3,400-11,600)
Heating Capacity Rated(Min.-Max.)
kWBtu/h
3.5 (1.2-3.8)11,900 (4,100-12,950)
3.5 kW Class FTXM35HVMV / RXM35HVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
3.5 (1.2-3.8)11,900 (4,100-12,950)
2.0 kW Class FTXM20HVMV / RXM20HVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
2.0 (1.0-2.6)6,800 (3,400-8,850)
Heating Capacity Rated(Min.-Max.)
kWBtu/h
2.0 (1.0-2.6)6,800 (3,400-8,850)
FTXM20/25/35HVMV
RXM20/25/35HVMV
NEWNEW
NEW
NEW
Heating Capacity Rated(Min.-Max.)
kWBtu/h
6.0 (1.6-6.7)20,500 (5,500-22,900)
6.0 kW Class FTHM60HVMV / RHM60HVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
6.0 (1.6-6.7)20,500 (5,500-22,900)
Heating Capacity Rated(Min.-Max.)
kWBtu/h
7.1 (2.1-7.5)24,200 (7,200-25,600)
7.1 kW Class FTHM71HVMV / RHM71HVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
7.1 (2.1-7.5)24,200 (7,200-25,600)
5.0 kW Class FTHM50HVMV / RHM50HVMVCooling Capacity Rated
(Min.-Max.)kWBtu/h
5.0 (1.6-6.0)17,700 (5,500-20,500)
Heating Capacity Rated(Min.-Max.)
kWBtu/h
5.0 (1.6-6.0)17,700 (5,500-20,500)
FTHM50/60/71HVMV
RHM50/60/71HVMV
indicates a model with a new design.NEW indicates a model with a new capacity class.NEW
Ozone depletion potential
RefrigerantRefrigerant piping
Global warming potential1
R-410AR-22
0.05 0 0
1,810 2,090 675
R-32
R-32 R-410A R-22
500
1,000
1,500
2,000
2,500
675
2,090 1,810
Global warming potential1Can your existing refrigerant piping be reused?
Important
Important
As the sole worldwide manufacturer of both air conditioning equipment and refrigerants, Daikin is continuously researching refrigerants as well as new technologies that can reduce energy consumption. Use of refrigerants with a lower impact on global warming is urgently required as climate change has become one of the most critical global issues. Daikin has now adopted R-32. This next-generation refrigerant does not deplete the ozone layer and has a lower impact on global warming.
The ozone layer surrounds the Earth and helps to absorb the harmful ultraviolet rays in sunlight. Although R-22 (HCFC) refrigerant had been used in air conditioners and refrigerators, it damages the ozone layer and its use is to be mostly elimi-nated by 2020. To replace R-22, Taiwan, Japan and European countries with more progressive regulations selected R-410A (HFC).
The Earth retains solar heat in the daytime for warming and then releases this heat at night, allowing it to maintain an optimal temperature range. However, with greenhouse gases increas-ing, it is more difficult to discharge heat and the planet is gradually becoming warmer. This is called global warming. R-32 has only around 30% of the global warming potential of R-410A and R-22.
The existing piping has:• no exterior damage• appropriate external/internal diameters• appropriate piping wall thickness• separate insulation for liquid and gas pipes.
The existing piping cannot be used. New piping is required.
Note: 1. Global warming potential values are based on the Fourth Assessment Report from the Intergovernmental Panel on Climate Change (IPCC).
Greenhouse gases cause damage which allows solar radiation to pass through the Earth’s outer atmosphere while also trapping infrared radiation. These gases rapidly increase and interfere with the Earth’s ability to release heat into space, causing the ambient temperature to rise.
Infrared radiation
LandSea
Solar radiation
Greenhouse gas
The potential refrigerating effect of R-32 is 1.5 times that of R-410A. Thus the piping diameter can be smaller.
15
Reuse of Existing Piping Next-Generation R-32 Refrigerant
Increased Energy Efficiency
Zero Ozone Layer Depletion
Replacement from R-22
Less Impact on Global Warming
You can reuse the existing piping when replacing a system that uses R-22/R-410A refrigerant with a new Daikin R-32 model. The piping can be changed over without cleaning up to its maximum length. This allows a Daikin air conditioner using R-32 refrigerant to be installed smoothly even with built-in piping.
Notes for Installation• Reuse depends on the oil stains that remain inside the existing
refrigerant piping. If the inside is extremely dirty, it is necessary to clean or replace the piping.
• Please perform pump-down cooling operation when removing the existing air conditioner. This takes 15 minutes for 2.5 to 7.1 kW models.
• If you have any enquiries, please contact your local distributor and/or retailer.
Smooth Replacement of Air Conditioners
16
The old air conditioner can perform pump-down cooling operation.
Recover the refrigerant using the appropriate equipment.
After performing pump-down cooling operation*1, close the liquid and gas stop valves.
Abrasion powder (iron powder, etc.) remains in the oil. Cleaning of the pipes is required.
Remove the old air conditioner.
Perform flare connection for R-32 using the flare nut supplied with the new air conditioner.
The new air conditioner can be installed with the existing refrigerant piping.
Yes
Yes
Yes
Yes
Yes
YesNo
No
No
Yes
Ozone depletion potential
Refrigerant
Global warming potential1
R-410AR-22
0.05 0 0
1,810 2,090 675
R-32
R-32 R-410A R-22
500
1,000
1,500
2,000
2,500
675
2,090 1,810
Global Warming Potential1
Refrigerant Flow during Cooling
Inverter air conditioners vary their capacity by adjust-ing the rotation speed of their compressors. In contrast, non-inverter models have a fixed capacity and can only control the room temperature by starting or stopping their compressors.
Inverter models operate at maximum capacity (100% load) to quickly reach the set temperature. They then reduce operation to low capacity (partial load), which is sufficient to maintain the set temperature. This allows inverter models to operate at low capacity (partial load) most of the time.
Inverter models finely adjust their capacity according to the heat load, minimising the difference between the set temperature and room temperature. This ensures higher comfort levels than with non-inverter models.
With the FTXV series, the set temperature can be changed in 0.5˚C steps. This precise control allows you to finely adjust the temperature to suit your personal comfort level.
Comfortable
Controls rotation according to required power
Maximum capacity 6.0 kW
Minimum capacity1.7 kW
Time
Rotations
InverterNon-inverter
Large loss of electricity
Time
Capacity
FTKV50NVMV
FTKV50NVMV
Maximum capacity
6.0 kWHigh compressor rotation speed
100% loadMedium compressor rotation speed
Partial load
Medium capacity
3.85 kW Minimum capacity
1.7kWSlow compressor rotation speed, Partial load
Inverters are devices that are able to vary their capacity by adjusting operating frequency. This allows inverter air condi-tioners to cut electricity use compared to non-inverter models. An inverter system can help to noticeably reduce household power bills.
If you select Auto Fan Speed, your inverter air conditioner will operate at maximum efficiency without any further setting. It will not start and stop its compressor to maintain the room temperature. You can also go out of the room for a short time without any worries.
Fanspeed Low High
SLAuto HL M
Too cool
Not cool
Temp.
Starts Time
Comfortable
Small temp.difference
Set temp.
Temperature fluctuation during cooling operation
Non-inverter
Inverter
Next-Generation R-32 Refrigerant
As the sole worldwide manufacturer of both air conditioning equipment and refrigerants, Daikin is continuously researching refrigerants as well as new technologies that can reduce energy consumption. Use of refrigerants with a lower impact on global warming is urgently required as climate change has become one of the most critical global issues. Daikin has now adopted R-32. This next-generation refrigerant does not deplete the ozone layer and has a lower impact on global warming.
The ozone layer surrounds the Earth and helps to absorb the harmful ultraviolet rays in sunlight. Although R-22 (HCFC) refrigerant had been used in air conditioners and refrigerators, it damages the ozone layer and its use is to be mostly elimi-nated by 2020. To replace R-22, Taiwan, Japan and European countries with more progressive regulations selected R-410A (HFC).
The Earth retains solar heat in the daytime for warming and then releases this heat at night, allowing it to maintain an optimal temperature range. However, with greenhouse gases increas-ing, it is more difficult to discharge heat and the planet is gradually becoming warmer. This is called global warming. R-32 has only around 30% of the global warming potential of R-410A and R-22.
Similar Mechanism to Human BodyAn air conditioner functions in a surpris-ingly similar way to the human body. In the body, blood carries heat as it circulates and helps to release excess heat through sweating. Refrigerant also carries heat and helps to adjust tempera-ture through heat exchange.
Effective Release of HeatRefrigerant is changed from gas to liquid in the outdoor heat exchanger, after which it is evaporated in the indoor heat exchanger. During cooling operation, cool air is discharged from the indoor unit while heat is removed from the air taken in from inside the room. This heat is delivered to the outdoor unit and released.
Refrigerants: Heat Release in Air Conditioning Systems
Note: 1. Global warming potential values are based on the Fourth Assessment Report from the Intergovernmental Panel on Climate Change (IPCC).
The potential refrigerating effect of R-32 is 1.5 times that of R-410A. Thus the piping diameter can be smaller.
Refrigeration Cycle of R-32
300
700
1,100
1,500
1,900
2,300
2,700
3,100
3,500
200 300 400 500 600
Enthalpy (kJ/kg)
Pres
sure
(kPa
)
R-22 refrigerating effect
R-32 refrigerating effect, 1.5 times that of R-22 or R-410A
R-32Te/Tc=12/43˚CSH/SC=6/6˚C R-410A
R-22
R-410A refrigerating effect
17
Inverter Air Conditioners Reduce Electricity ConsumptionIncreased Energy EfficiencyLower Electricity Consumption
No Starting and Stopping
Comfortable
Powerful and Energy Saving
Zero Ozone Layer Depletion
Less Impact on Global Warming
18
The FTXV series achieves CSPFs of 4.65 to 6.35 thanks to Daikin’s DC Inverter control and next-generation R-32 refrigerant. For this series, all models have earned Vietnam’s highest Grade 5 energy efficiency rating.
CSPF (cooling seasonal performance factor) is the annual operating efficiency of an air conditioner under conditions close to actual conditions for specific applications (buildings, etc.) and operating periods.
It represents the integral cooling capacity per kilowatt hour of power consumption for an air conditioner that operates under fixed conditions throughout the year.
What Is CSPF?
DC Inverter ControlDC Inverter is Daikin’s term for an inverter air conditioner equipped with a DC motor. These motors use magnets to generate rotation, making them more efficient than AC motors. Daikin has fitted its advanced DC motors for compressors and fan motors with powerful neodymium magnets to achieve even greater efficiency. It calls these devices Reluctance DC motors.
Reluctance DC Motor for Compressors
The compressor is one of an air conditioner’s core components and its performance is directly linked to the motor. Daikin was the first to successfully use a Reluctance DC motor with a scroll compressor in commercial-use air conditioners2. It has now adapted this high-efficiency motor for the swing compressors in its residential-use systems. The Reluctance DC motor saves energy by generating more power with a smaller electric current than AC or conventional DC motors.
Swing CompressorWith its smooth rotation, the swing compressor significantly decreases friction and vibration. It also eliminates the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation.
The high performance of this Daikin original technology was recognised in 1997 with the receipt of an award from the Japan Society for the Promotion of the Machine Industry1. The compressor’s reputation for reliability has grown considerably in the nearly 20 years since this award was presented.
Embedding high-strength neodymium magnets in the shaft turns the entire centre of the motor into a powerful magnet. By rapidly switching the poles of this electromagnet, the Reluctance DC motor is able to produce even greater speed and power.
Neodymium magnet
Repelling powerElectromagnet
Rapid switching
Magnetic power
Reluctance DC motor
Swing compressor
Reluctance DC motor
FTXV25QVMV 6.21
Energy label CSPF
4 5 6
Gra
de 5
Gra
de 5
This marked the development of a high-performance swing compressor that was compatible with alternative fluorocarbons.Daikin’s achievement was recognised by the Institute of Electrical Engineers of Japan at the 54th Academic Promotion and Technical Development Awards in 1998.
Notes: 1.
2.
Total capacity during cooling (kWh)Total power consumption during cooling (kWh)
CSPF =
New Conventional
FTXD25HVMV 3.98
FTXV35QVMV 6.24
FTXD35HVMV 4.93
Gra
de 5 FTXV50QVMV 6.35
FTXD50HVMV 5.07
Gra
de 5 FTXV60QVMV 5.81
FTXD60HVMV 4.50
Gra
de 5 FTXV71QVMV 4.65
FTXD71HVMV 3.85
Controls rotation according to required power
Large loss of electricity
Inverters are devices that are able to vary their capacity by adjusting operating frequency. This allows inverter air condi-tioners to cut electricity use compared to non-inverter models. An inverter system can help to noticeably reduce household power bills.
If you select Auto Fan Speed, your inverter air conditioner will operate at maximum efficiency without any further setting. It will not start and stop its compressor to maintain the room temperature. You can also go out of the
19
All Models Feature High Ene rgy RatingsCSPFs of 4.65 to 6.35 Daikin DC Inverter Technologies
20
21 22
Less Wasted Energy with Infr ared Sensors
Two-Area Intelligent Eye Intelligent Eye
Econo Mode Standby Electricity Saving
If a person is detected in area A, airflow is directed toward area B.
Intelligent Eye sensor
Intelligent Eye indicator
This function uses its infrared sensor to direct airflow either toward or away from people. It also prevents energy wastage by detecting human movement in a room. If there is no movement for 20 minutes, it automatically adjusts the set temperature by approximately 2°C.This function is available for the FTXV25/35.
This function is available for the FTKV series, FTXV50/60/71, FTKC series and FTHM series.
This function is not available for the FTKV25/35 and FTXM series.
Area A Area B
Area A Area B
Area A Area B
If a person is detected in area A, airflow is directed toward area A.
If a person is detected in area B, airflow is directed toward area B.
If no one is detected in either area A or B for 20 minutes, Intelligent Eye automatically adjusts the set temperature by approximately 2˚C.
Area A Area B
Area A Area B
Area A Area B
Directs airflow away from people to prevent drafts Directs airflow toward people to increase cooling
Saves energy
Intelligent Eye
This function limits the maximum power consumption. It helps to reduce power usage if the cooling load is high, for example, at startup or during large gatherings and periods of direct sunshine.
Standby Electricity Saving
Electrical appliances still use a surprising amount of power even when they are waiting in standby mode. Recognising this, Daikin has developed the Standby Electricity Saving function to reduce this hidden power consumption.
Time
Normal operationPo
wer
con
sum
ptio
n
Econo Mode
Maximum capacity decreases during Econo Mode, requiring more time to reach the set temperature.
Intelligent Eye prevents energy wastage by using its infrared sensors to detect human movement in a room. If there is no movement for 20 minutes, it automatically adjusts the set temperature by approximately 2°C. Once Intelligent Eye is turned on, it operates automatically without any further setting.
If people are detected in both area A and B, airflow is directed toward area A.
If a person is detected in area B, airflow is directed toward area A.
If Intelligent Eye detects no movement for 20 minutes, it adjusts the set temperature by approximately 2°C.
When a person enters the room, it automati-cally returns the temperature to the set level.
23 24
Choice of Wide Range of Air flow Patterns
The Power-Airflow Flap and Power-Airflow Dual Flaps flatten out during cooling operation to deliver air to every part of a room. The flap can direct warm air straight down to the floor during heating operation. Selecting the low angle sends air right to the corners, while choosing the high angle spreads air around the centre.
Power-Airflow Flap and Power-Airflow Dual Flaps
Inverter Powerful Operation boosts airflow to maxi-mum volume for a 20 minute period. This function is convenient for quickly adjusting the indoor temperature to the set temperature. After 20 minutes, the unit automatically returns to its previ-ous settings.
Inverter Powerful Operation
Comfort Airflow Mode prevents uncomfortable drafts from blowing directly on to a person’s body. This setting redirects air by moving the flap upward during cooling operation and downward during heating operation.
Comfort Airflow Mode
The Wide-Angle Louvers provide effective airflow coverage no matter where the indoor unit is placed in a room. The louvers deliver cool and warm air right to the corners of any space. The FTKV50/60/71 and FTXV series can be adjusted directly from the wireless remote controller. Other units can be set manually.
Wide-Angle Louvers
3D Airflow combines Vertical and Horizontal Auto-Swing to reduce indoor temperature fluctuation. This function circulates air to every part of a room for uniform cooling or heating of even large spaces. To start 3D Airflow, push both the Vertical and Horizontal Auto-Swing buttons. The flaps and louvers swing in turn.
3D Airflow
When you choose the low angle, cool air slides off to reach the corners of the room.
The angles of the louvers can be freely adjusted according to where people are in the room. If the indoor unit is not positioned in the centre of the wall, the louvers can be set to the left or right.
The louvers cover even a spacious room.
1
2
3
4
The flaps and louvers swing in turn, expanding the comfort zone.
20minutes
The Power-Airflow Flap is available for the FTXV25/35, FTKC25/35 and FTXM series.The Power-Airflow Dual Flaps are available for the FTKV series, FTXV50/60/71, FTKC50/60/71 and FTHM series.
This function is available for the FTKV50/60/71 and FTXV series. This function is not available for the FTKV25/35.
Cooling Heating
Indoor unit
19
25 26
Quiet Nights in Your Neighbo urhood
The whole series give you a choice of 5-step, Quiet or Automatic settings for the fan speed. The Quiet setting selects Indoor Unit Quiet Operation, which decreases the sound pressure level by 3 to 9 dB (A) below the Low setting.
This wide range of settings allows you to precisely control the fan speed according to your needs. For example, the Quiet function will help you to sleep more comfort-ably at night. The sound pressure level is just 19 dB (A)1 for the FTXV25/35 and FTKC25.
Indoor Unit Quiet Operation Night Set Mode
24 Hour On/Off TimerThis function decreases the sound pressure level by 3 to 7 dB (A) below the rated operation. It provides a sound pressure level of 43 dB (A)1 for the RKV25, RXV25, RKC50/60 and RHM50/60. Capacity may decrease when Outdoor Unit Quiet Operation is selected.
Outdoor Unit Quiet Operation
Rustling of leaves Pendulum of a wall clock Normal officeLibrary
Outdoor unit
(dB (A))30 40 43 5020
19 dB (A) is so quiet you can even hear whispers2
FTXV25 during cooling operation
High (H)
Low (L)
Quiet (SL)
40 dB (A)
25 dB (A)
19 dB (A)
Sound pressure levelsFan speeds
Each decrease in airflow volume reduces the sound pressure level.
Fan speed
Sound pressure level
Low High
SLAuto HL M
6 dB (A)
RKC60
Rated (H)
Quiet (SL)
50 dB (A)
43 dB (A)
Sound pressure levelsOperations
7 dB (A)
This value is for operation at 220 V, 50 Hz. Based on “Examples of Sound Pressure Levels”, Ministry of the Environment, Japan, November 2002.
Notes: 1. 2.
This function is not available for the RXM20/25/35.
This function is not available for the FTKC series and FTHM series.
This function is available for the FTXV series, FTKC series and FTHM series.
This timer can start or stop the air conditioner within a 24 hour period. It can be preset in 10 minute steps by pressing the On/Off Timer button on the wireless remote controller. The On Timer and Off Timer can be used in combination.
Count Up-Down On/Off Timer The operation start and stop times can be set with the touch of a single button and preset for a period of one to 12 hours in one hour increments. When the Off Timer is set, Night Set Mode is activated automatically.
Pressing the Off Timer button automatically selects Night Set Mode. This function prevents excessive cooling or heating for a pleasant sleep. After 60 minutes, the room temperature is raised by 0.5°C for cooling operation or lowered by 2°C for heating operation.
Time
Cooling
Heating
60 minutes
Set temp. beforeOff timer begins
to operate
Off timer turns on Off timer stops air conditioner
+0.5°C
-2°C
Off timer at 1:00 a.m. and On timer at 6:00 a.m.
Stops the unit after three hours and starts it again eight hours later.
27 28
Set and Forget On/Off Opera tion
The Weekly Timer allows up to four actions to be programmed for each day of the week. It is possible to schedule not only the On and Off times but also to set temperatures. Once you set up the Weekly Timer, the air conditioner operates each day without controller input. The Weekly Timer synchronises the air conditioner with your family’s schedule, greatly improving comfort in your home.
You can set up the Weekly Timer using the wireless remote controller. The copy function also enables a daily programme to be repeated on other days as required. This makes it even easier to set the timer.
Controller Buttons and Copy Function
Weekly Timer
Deactivates, reactivates or deletes.
Copies settings.Moves back.
Moves forward.
Selects timer, mode, setting significant number, day, time and temperature.
Starts and completes settings.
This function is available for the FTKV50/60/71 and FTXV series.
27 28
Set and Forget On/Off Opera tion
The Weekly Timer allows up to four actions to be programmed for each day of the week. It is possible to schedule not only the On and Off times but also to set temperatures. Once you set up the Weekly Timer, the air conditioner operates each day without controller input. The Weekly Timer synchronises the air conditioner with your family’s schedule, greatly improving comfort in your home.
You can set up the Weekly Timer using the wireless remote controller. The copy function also enables a daily programme to be repeated on other days as required. This makes it even easier to set the timer.
Controller Buttons and Copy Function
Weekly Timer
Bedroom Monday to Friday
Programme 1.
22ºC 21ºC6:00 a.m
On
8:00 a.m
OffProgramme 2.
6:00 p.m
On
11:00 p.m
OffProgramme 3. Programme 4.
If you set the Weekly Timer 30 minutes before your wake-up time, you can avoid the hot and humid morning air and enjoy a pleasantly cool room as you get up.
The Weekly Tim er will automatically stop operation after you leave home on a busy morning. You can forget about the air conditioner.
If you set the Weekly Timer an hour before you arrive home, you can enjoy a wave of cool air as soon as you step through the door.
The Weekly Timer will automatically stop operation when you go to bed.
Even if you go to bed at 11:00 p.m., the air conditioner will operate before 30 minutes to help you fall into a comfort-able sleep.
Even if you go to bed at 11:00 p.m., the air conditioner will operate for another three hours to help you fall into a comforta ble sleep. Stopping operation during the night preve nts overcooling and saves you from catching a chill.
If you set the Weekly Timer 30 minutes before your wake-up time, you can avoid the hot and humid morning air and enjoy a pleasantly cool room as you get up.
The Weekly Timer will automatically stop operation when you leave home.
Deactivates, reactivates or deletes.
Copies settings.Goes back.
Goes next.
Selects timer, mode, setting significant number, day, time and temperature.
Starts and completes settings.
Living room Monday to Friday
Programme 1.
26ºC 26ºC10:30 p.m
On
2:00 a.m
OffProgramme 2.
6:00 a.m
On
7:00 a.m
OffProgramme 3. Programme 4.
This function is available for the FTKV50/60/71 and FTXV series.
Programme 1
22ºC6:30 a.m.
On
Programme 2
8:00 a.m.
Off
Programme 4
0:00 a.m.
Off
Programme 3
21ºC5:30 p.m.
On
Programme 1
23ºC11:30 p.m.
On
Programme 2
3:00 a.m.
Off
Programme 4
8:00 a.m.
Off
Programme 3
23ºC6:30 a.m.
On
Living room Monday to Friday Bedroom Monday to Friday
If you set the Weekly Timer 30 minutes before your wake-up time, you can avoid the hot and humid morning air and enjoy a pleasantly cool room as you get up.
Even if you go to bed at 0:00 a.m., the air conditioner will start operation 30 minutes before to help you fall into a comfortable sleep.
The Weekly Timer will automatically stop operation after you leave home on a busy morning. You can forget about the air conditioner.
Even if you go to bed at 0:00 a.m., the air conditioner will operate for another three hours so you continue to sleep comfortably. Stopping operation during the night prevents overcooling and saves you from catching a chill.
If you set the Weekly Timer an hour before you arrive home, you can enjoy a wave of cool air as soon as you step through the door.
If you set the Weekly Timer 30 minutes before your wake-up time, you can avoid the hot and humid morning air and enjoy a pleasantly cool room as you get up.
The Weekly Timer will automatically stop operation when you go to bed. The Weekly Timer will automatically stop operation when you leave home.
Programme 1
22ºC7:00 a.m.
OnProgramme 2
8:00 a.m.
OffProgramme 4
0:00 a.m.
OffProgramme 3
21ºC5:30 p.m.
OnLiving room Monday to Friday
If you set the Weekly Timer 30 minutes before your wake-up time, you can avoid the hot and humid morning air and enjoy a pleasantly cool room as you get up.
The Weekly Timer will automatically stop operation after you leave home on a busy morning. You can forget about the air conditioner.
If you set the Weekly Timer an hour before you arrive home, you can enjoy a wave of cool air as soon as you step through the door.
The Weekly Timer will automatically stop operation when you go to bed.
29 30
Photocatalytic Air Purifying
Titanium Apatite Photocatalytic Air-Purifying Filter
The outdoor unit’s heat exchanger fins are processed using a special anti-corrosion treatment. The surface is covered with a thin acrylic resin layer to provide enhanced resis-tance to acid rain and salt corrosion.
Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins
Photocatalytic air purifying is a deodorising and antibacterial technology. Daikin was the first to apply this advance to the air-purifying filters used in air conditioners1. Daikin’s success has led manufacturers in various industries to adopt the technology for antibacterial products.
Titanium apatite is an advanced photocatalytic material with great adsorption power. While a filter’s micron-level fibres trap dust, titanium apatite effectively adsorbs and decomposes bacteria. The photocatalyst is activated simply by exposure to light. This filter delivers consistent performance for approximately three years if it is washed with water once every six months.
This filter is not a medical device. Benefits such as the adsorption and decomposition of bacteria are only effective for substances which are directly attached to the Titanium Apatite Photocatalytic Air-Purifying Filter.
Effect of Titanium Apatite Photocatalyst
Titanium Apatite Photocatalyst
LightAdsorbs Removes
Odours Bacteria Decomposed
Heat exchanger fin
Hydrophilic filmAluminium
Corrosion-resistantacrylic resin
Cross section of anti-corrosion treated fin
This practical application of titanium apatite was a world first. Announced in September 2003 at the 3rd International Workshop on the Utilization and Commercialization of Photocatalytic Systems, Coatings for Clean Surfaces, Water and Air Purification.
Note: 1.
Titanium Apatite Photocatalytic Air-Purifying Filter
Air filter catches dust
New PageAt home, the Daikin mobile controller applica-tion turns your smartphone into a centralised remote controller.2 It only takes a few easy taps to check and adjust the temperature in a child’s room on the second floor from the living room. You can also start and stop the air conditioner in the living room from your bedroom.
In HomeOperation
The Daikin mobile controller application takes care of those nagging worries about whether you turned off the air conditioner and ensures a comfortable air conditioned environment is waiting when you return home. Even outside your home, you can easily monitor and adjust points such as the operating status and room temperature or start and stop all units.
Out of HomeOperation
Start/stop operation Monitor current outdoor temperature4
Set child-proof lock3
Set fan speed3
Set airflow direction3
Set room temperature Set weekly timer:
Set operation mode
Notes: 1. For applicable OSs, go to http://www.daikinthai.com/dmobile/. An Internet connection is required to use this service. Standard smartphone charges also apply when using the Daikin mobile controller application to monitor or control air conditioners. 2. In-home control of air conditioners using the Daikin mobile controller application will depend on the effective coverage area of your LAN. 3. The controllable functions differ depending on the model. 4. Monitoring of the outdoor temperature is available for all models during operation. Some models can also perform monitoring while they are not operating. 5. An interface adaptor (KRP067A41 or KRP980B2) is also required for the FTXV series, FTKC series and FTHM series.
Notes: 1. For applicable OSs, go to http://www.daikinthai.com/dmobile/. An Internet connection is required to use this service. Standard smartphone charges also apply when using the Daikin mobile controller application to monitor or control air conditioners. 2. In-home control of air conditioners using the Daikin mobile controller application will depend on the effective coverage area of your LAN. 3. The controllable functions differ depending on the model. 4. Monitoring of the outdoor temperature is available for all models during operation. Some models can also perform monitoring while they are not operating.
Required for Operation
System Configuration
Functions
+++ +
Wireless Internet Environment at Home
BRP072A42(2)Daikin mobile controller application (free)
(3)Wireless router
* Android is a trademark of Google Inc.** iPhone is a trademark of Apple Inc.
Daikin mobile controller (optional adaptor) (1)
AndroidTM* phone or iPhone**
Smartphone
BRP072A42
Wireless router
Internet
Internet
Daikin mobile controller(optional adaptor) Daikin mobile controller
application (free)Simply download the application and register your air conditioners.
Monitor current room temperature
This optional adaptor is not available for the FTXM series.For applicable models, go to http://www.daikinthai.com/dmobile/. A Daikin mobile controller (optional adaptor) is required for each indoor unit to enable control from smartphones.
Users need to prepare items (1) to (3). A Daikin mobile controller (optional adaptor) is required for each indoor unit.
The Daikin mobile controller application lets you manage Daikin inverter air conditioners from anywhere, helping to maintain a comfortable home environment while saving energy.
This convenient app gives you full control of core functions such as start/stop, opera-tion mode and set temperature as well as advanced features like weekly scheduling. The app also lets you monitor your system to ensure it is performing as desired.
Setup is extremely easy. After downloading the software, you only need to connect to a private wireless network inside your home or mobile network outside.1
• Start/stop operation • Operation mode• Room temperature (maximum of four actions per day, 28 actions in total)
31 32
Remote Control via Smartph one
Titanium Apatite Photocatalytic Air-Purifying Filter
Photocatalytic air purifying is a deodorising and antibacterial technology. Daikin was the first to apply this advance to the air-purifying filters used in air conditioners1. Daikin’s success has led manufacturers in various industries to adopt the technology for antibacterial products.
Titanium apatite is an advanced photocatalytic material with great adsorption power. While a filter’s micron-level fibres trap dust, titanium apatite effectively adsorbs and decomposes bacteria. The photocatalyst is activated simply by exposure to light. This filter delivers consistent performance for approximately three years if it is washed with water once every six months.
Smart Control by Smartphone
KRP067A41 or KRP980B2
Remote control PC-board set5 (optional adaptor)
KRP067A41 or KRP980B2
Remote control PC-board set5 (optional adaptor)
Automatic Operation
33 34
Indoor Unit
Function List FTKV FTXV FTXM and FTHM
Wide-Angle Louvers
Power-Airflow Flap
Power-Airflow Dual Flaps
DC Inverter Control
Horizontal Auto-Swing (left and right)
Vertical Auto-Swing (up and down)
Comfort Airflow Mode
3D Airflow
Intelligent Eye
Indoor Unit Quiet Operation
Auto Fan Speed
Programme Dry Function
Standby Electricity Saving
Inverter Powerful Operation
Econo Mode
Indoor Unit On/Off Switch
Wireless Remote Controller with Backlight
Daikin Mobile Controller (optional adaptor)
Wipe-Clean Flat Panel
Titanium Apatite Photocatalytic Air-Purifying Filter
Weekly Timer
24 Hour On/Off Timer
Auto-Restart after Power Failure
Night Set Mode
Self-Diagnosis with Digital Display
Outdoor Unit Quiet Operation
Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins
FTKV25/35 FTKV50/60 FTKV71 FTXV25/35 FTXV50/60/71 FTXM20/25/35 FTHM50/60/71
Outdoor Unit FTKV
RKV25/35 RKV50/60 RKV71
FTXV
RXV25/35 RXV50/60/71
FTXM and FTHM
RXM20/25/35 RHM50/60/71
Com
fort
Cont
rol
Life
styl
e Co
nven
ienc
eCl
eanl
ines
sW
orry
Fre
e
Comfort Control
Worry Free
Com
forta
ble
Airfl
owTi
mer
s
Models
Functions
Models
Functions
Count Up-Down On/Off Timer
Two-Area Intelligent Eye
FTKC
FTKC25/35 FTKC50/60/71
FTKC
RKC25/35 RKC50/60/71
Cooling Only Cooling OnlyHeat Pump Heat Pump
Side view7 m
Top view
7 m
110˚90˚
35 36
Indoor Unit On/Off Switch
Heat exchanger fin
Hydrophilic filmAluminium
Corrosion-resistantacrylic resin
Cross section of anti-corrosion treated fin
Functions
See page 22
See page 22
See page 26
See page 26
See page 30
See page 24
See page 25
See page 25
See page 22
See page 17
See page 30
See page 23
See page 23
See page 24
See page 24
Wide-Angle Louvers
Vertical Auto-Swing (up and down)
Auto Fan Speed
Programme Dry Function
Indoor Unit Quiet Operation
Inverter Powerful Operation
Econo Mode
Indoor Unit On/Off Switch
Night Set Mode
Auto-Restart after Power Failure
Self-Diagnosis with Digital Display
Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins
Wipe-Clean Flat Panel
Titanium Apatite Photocatalytic Air-Purifying Filter
Comfort Airflow Mode
24 Hour On/Off Timer
Comfortable Airflow Comfort ControlLifestyle Convenience
Cleanliness
Timers
The Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room.
This function automatically moves the flaps up and down to distribute air across a room.
The microprocessor automatically adjusts the fan speed to high to rapidly reach the set temperature. Once the temperature is achieved, this function reduces the fan speed to low.
The microprocessor works to eliminate humidity while maintaining the most consistent temperature possible. It automatically controls the temperature and fan speed.
Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement for 20 minutes, it adjusts the temperature by approximately 2°C for energy savings.
Indoor unit operating sound pressure levels are decreased from the Low setting fan speed using the wireless remote controller.
This function boosts cooling or heating performance for a 20 minuteperiod. It is convenient when it is necessary to change the room temperature quickly.
This mode limits the maximum power consumption. It improves operating efficiency and also prevents circuit breakers from being overloaded.
The unit can be conveniently started by hand if the wireless remote controller is misplaced or its batteries are not charged.
This optional adaptor and its application turn a smartphone into a remote controller that can be used inside or outside the home. Together they help to maintain comfort while saving energy and eliminate any worries about forgetting to turn off the air conditioner.
The flat panel design can be cleaned with only the single pass of a cloth across its smooth surface. The flat panel can also be easily removed for more thorough cleaning.
Pressing the Off timer button automatically selects Night Set Mode. This function prevents excessive cooling or heating for a pleasant sleep. After 60 minutes, the room temperature is raised by 0.5˚C for cooling operation or lowered by 2˚C for heating operation.
Worry Free
The air conditioner memorises the settings for operation mode (automatic, cooling, heating, dry and fan only), airflow, temperature, etc., and automatically returns to them when power is restored after a power failure.
Malfunction codes are shown on the digital display panel of the wireless remote controller for fast and easy maintenance.
The outdoor unit’s heat exchanger fins are processed using a special anti-corrosion treatment. The surface is covered with a thin acrylic resin layer to enhance the fins’ resistance to acid rain and salt corrosion.
This filter contains the advanced photocatalytic material titanium apatite. While the filter’s micron-level fibres trap dust, this photocatalyst adsorbs and decomposes bacteria. The filter can be used for up to three years with proper maintenance.
This function prevents uncomfortable drafts from blowing directly on to the body. To prevent drafts, the flap moves upward during cooling operation and downward during heating operation.
This timer can start or stop the air conditioner within a 24 hour period. It can be preset in 10 minute steps by pressing the On/Off timer button on the wireless remote controller. The On timer and Off timer can be used in combination.
Automatic OperationThis function automatically selects cooling or heating operation mode based on the room temperature at startup.
Power-Airflow FlapThe Power-Airflow Flap flattens out during cooling operation to deliver cool air to the corners of a room. The flap also directs warm air straight down to the floor during heating operation.
See page 23
Horizontal Auto-Swing automatically moves the louvers to the left and right to cover a room with cool or warm air.
This function combines Vertical and Horizontal Auto-Swing to circulate a cloud of cool or warm air right to the corners of even large spaces. The flaps and louvers swing in turn.
Horizontal Auto-Swing (left and right)
3D AirflowSee pages 31 and 32
Even when an air conditioner is not operating, it requires standby power. However, thanks to this function, the required standby power can be reduced.
Standby Electricity Saving
See page 26
See pages 27 and 28
Count Up-Down On/Off TimerThe operation start and stop times can be set with the touch of a single button and preset for a period of one to 12 hours in one hour increments. When the Off Timer is set, Night Set Mode is activated automatically.
Weekly TimerThe Weekly Timer allows up to four actions to be programmed foreach day of the week. It is possible to schedule not only the on andoff times, but also the desired temperatures during these periods. Thecopy function also makes the setting much easier and enables a dailyprogramme to be repeated on other days as required.
The backlit LCD allows easy operation in the dark. Frequently used functions are conveniently located on the front of the controller.
Wireless Remote Controller with Backlight
The Power-Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation.
Power-Airflow Dual Flaps
Intelligent Eye
See page 21
This function uses its infrared sensor to direct airflow either toward or away from people. If there is no human movement in a room for 20 minutes, it also automatically adjusts the set temperature by approxi-mately 2°C to prevent energy wastage.
Two-Area Intelligent Eye
Daikin Mobile Controller (optional adaptor)
Outdoor unit operating sound pressure levels can be decreased from the rated operation sound using the wireless remote controller.
Outdoor Unit Quiet Operation
1
23
4
5
78
1
2
3
4
5
67
1
2
10
1112
613
1415
9
8
910
11121314
10
11
6
12
13
149
3
4
8
9
10
11
12
13
14
9
10
11
12
13
14
15
1716
10
11
13
9
12
14
15
16
17
1
2
3
4
5
6
7
1
2
3
4
5
67
8
1
2
3
4
5
6
7
8
5
7
8
Moves back.
Deactivates, reactivates or deletesWeekly Timer setting.
Copies settings.
Weekly Timer:
Moves forward.
Starts and completes settings.
Weekly
Copy
Back
Next
1
23
45
78
1
2
10
1112
613
1415
9
10
11
6
12
13
14
15
15
9
3
4
5
7
8
Moves back.
Deactivates, reactivates or deletesWeekly Timer setting.
Copies settings.
Weekly Timer:
Moves forward.
Starts and completes settings.
Weekly
Copy
Back
Next
Wireless Remote Controller
Wireless Remote Controller with Backlight
FTHM/50/60/71
FTXM20/25/35
On and Off switch
Selects fan speed.Auto Fan Speed and
� Indoor Unit Quiet Operation
Inverter Powerful Operation
Selects operation mode:Automatic Operation,
Cooling, Heating, Dry and Fan Only.
Sets room temperature.
Econo Mode andOutdoor Unit Quiet Operation
Two-Area Intelligent Eye
Sets room temperature.
Econo Mode
Inverter Powerful Operation
Outdoor Unit Quiet Operation Comfort Airflow Mode
Selects vertical airflow direction. Vertical Auto-Swing and 3D Airflow
Selects horizontal airflow direction. Horizontal Auto-Swing and 3D Airflow
Sets time.Sets clock.
Cancels timers.
24 Hour On Timer
24 Hour Off Timer and Night Set Mode
On and Off switch
Selects fan speed. Auto Fan Speed and Indoor Unit Quiet Operation
Selects vertical airflow direction. Vertical Auto-Swing
Sets time.
Cancels timer.
Sets clock.
Resets settings.
Starts dry operation.
Starts fan only operation.
Econo Mode �
Off switch
Selects fan speed. Auto Fan Speed and Indoor Unit Quiet Operation
Selects airflow angle. Vertical Auto-Swing
Night Set Mode andCount Up-Down Off Timer
Comfort Airflow Mode
Cancels timers.
Starts operation.�Automatic Operation
Starts cooling operation.
Starts heating operation.
Sets room temperature.
Outdoor Unit Quiet Operation
37 38
FTXV25/35
FTXV Series FTXM and FTHM Series
FTXV50/60/71
Selects operation mode:Automatic Operation,
Cooling, Heating, Dry and Fan Only.
Wireless Remote Controller with Backlight
On and Off switch
Selects fan speed.Auto Fan Speed and
� Indoor Unit Quiet Operation
Inverter Powerful Operation
Selects operation mode:Automatic Operation,
Cooling, Heating, Dry and Fan Only.
Sets room temperature.
Econo Mode andOutdoor Unit Quiet Operation
Intelligent Eye
Comfort Airflow Mode
Selects vertical airflow direction. Vertical Auto-Swing and 3D Airflow
Selects horizontal airflow direction. Horizontal Auto-Swing and 3D Airflow
24 Hour On Timer and Count Up-Down On Timer �
Sets time.Sets clock.
24 Hour Off Timer,Count Up-Down Off Timer and
Night Set Mode
Cancels timers.
24 Hour On Timer and Count Up-Down On Timer �
Count Up-Down On Timer
24 Hour Off Timer,Count Up-Down Off Timer and
Night Set Mode
Inverter Powerful Operation
Intelligent Eye
Specifications
39 40
FTKV Series FTXV Series FTKV25NVMVRKV25NVMV2.5 (1.2-3.4)
8,500 (4,100-11,600)
2.7 5406.14
FTKV25NVMV
7.8 (275)
37/25/22
RKV25NVMV
46/43
FTKV35NVMVRKV35NVMV3.5 (1.3-4.1)
11,900 (4,400-14,000)
4.4 9105.44
FTKV35NVMV
8.0 (282)
38/26/23
RKV35NVMV
47/44
FTKV50NVMVRKV50NVMV5.2 (1.7-6.0)
17,700 (5,800-20,500)
6.0 1,3006.09
FTKV50NVMV
14.3 (504)
43/34/31
RKV50NVMV
48/44
FTKV60NVMVRKV60NVMV6.0 (1.9-7.0)
20,500 (6,500-23,900)
7.4 1,5805.89
FTKV60NVMV
15.4 (544)
45/35/32
RKV60NVMV
52/46
FTKV71NVMVRKV71NVMV7.1 (2.3-8.9)
24,200 (7,800-30,400)
9.3 2,0005.19
FTKV71NVMV
18.2 (643)
46/37/33340 x 1,050 x 248
14RKV71NVMV
2,400
1.552/49
770 x 900 x 32060
ø15.9
Indoor unitOutdoor unitModel name
Capacity
Power supplyRunning currentPower consumptionCSPFIndoor unitFront panel colourAirflow rateFan speedSound pressure levelsDimensionsMachine weight Outdoor unitCasing colour
Compressor
Refrigerant Sound pressure levelsDimensionsMachine weightOperation range
Piping connection
Max. piping lengthMax. level difference
Rated (Min.-Max.)
Rated
LiquidGas
Drain
kW
Btu/h
AW
m3/min (cfm)
dB (A)mmkg
W
kgdB (A)
mmkg
°CDB
mm
m
Motor output
Charge volumeH/SL
H x W x D
H/L/SLH x W x D
H
Type
Type
FTXV25QVMVRXV25QVMV2.5 (0.9-3.7)
8,500 (3,100-12,600)3.2 (0.9-5.3)
10,900 (3,100-18,100)
2.3 3.1
490 (230-1,050)650 (190-1,480)
6.21 FTXV25QVMV
10.0 (353)10.1 (357)
40/25/1940/28/20
RXV25QVMV
47/4348/44
FTXV35QVMVRXV35QVMV3.5 (0.9-4.2)
11,900 (3,100-14,300)3.7 (0.9-5.3)
12,600 (3,100-18,100)
3.9 3.7
810 (230-1,300)770 (190-1,440)
6.24 FTXV35QVMV
10.5 (371)11.0 (388)
42/26/1942/29/20
RXV35QVMV
49/4449/45
FTXV50QVMVRXV50QVMV5.0 (1.1-6.7)
17,100 (3,800-22,900)6.0 (1.0-8.0)
20,500 (3,400-27,300)
5.5 6.4
1,140 (280-2,000)1,330 (220-2,350)
6.35 FTXV50QVMV
Pure white16.0 (565)17.2 (607)
45/35/2845/33/28
RXV50QVMV
47/4448/45
-10 to 46-15 to 18
ø6.4
ø16.0
FTXV60QVMVRXV60QVMV6.0 (1.1-7.5)
20,500 (3,800-25,600)7.2 (1.0-8.6)
24,600 (3,400-29,300)
7.2 8.3
1,520 (280-2,380)1,740 (220-2,650)
5.81 FTXV60QVMV
18.6 (657)20.0 (706)
48/36/2948/33/29
295 × 990 × 26313
RXV60QVMV
49/4552/45
695 x 930 x 350
3020
FTXV71QVMVRXV71QVMV7.1 (2.0-8.9)
24,200 (6,800-30,400)8.0 (2.0-10.6)
27,300 (6,800-36,200)
9.2 9.5
1,930 (450-3,350)2,020 (390-3,580)
4.65FTXV71QVMV
18.6 (657)19.7 (696)
49/37/3049/35/30
RXV71QVMV
2,400
1.6053/4954/49
60
ø15.9
Indoor unitOutdoor unitModel name
Capacity
Power supply
Running current
Power consumption
CSPFIndoor unitFront panel colour
Airflow rate
Fan speed
Sound pressure levels
DimensionsMachine weight Outdoor unitCasing colour
Compressor
Refrigerant
Sound pressure levels
DimensionsMachine weight
Operation range
Piping connection
Max. piping lengthMax. level difference
Rated
(Min.-Max.)
Rated (Min.-Max.)
Rated
Rated (Min.-Max.)
Cooling
Heating
CoolingHeatingCoolingHeating
CoolingHeating
CoolingHeating
CoolingHeating
CoolingHeatingLiquidGas
Drain
kW
Btu/h
kW
Btu/h
A
W
m3/min (cfm)
dB (A)
mmkg
W
kg
dB (A)
mmkg
°CDB°CWB
mm
m
Motor output
Charge volume
H x W x D
H x W x D
H/L/SL
H
H/SL
Type
Type
1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Pure white
5 steps, quiet and automatic
Ivory whiteHermetically sealed swing type
R-32
19.4 to 46 ø6.4
ø18.0
290 x 1,050 x 25012
283 x 800 x 1959
550 x 765 x 28534
ø9.5
2015
735 x 825 x 30043
ø12.7
800
0.9
1,300
1.2
3020
285 × 770 × 2239
ø9.5
2015
800
0.85
550 x 675 x 28430
1,300
1.50
54
ø12.7
1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
5 steps, quiet and automatic
Ivory whiteHermetically sealed swing type
R-32
Measurement conditions1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.2. Sound pressure levels are based on the temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of
ambient conditions.3. CSPF is based on TCVN 7830: 2012 conditions.
Note: The above values are based on operation with a 220 V, 50 Hz power supply.
Measurement conditions1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 5 m.2. Heating capacity is based on: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; piping length 5 m. 3. Sound pressure levels are measured in an anechoic chamber based on the temperature condition 1 and 2 above. These values are normally somewhat higher during actual operation as a result of
ambient conditions.4. CSPF is based on TCVN 7830: 2012 conditions.
Note: The above values are based on operation with a 220 V, 50 Hz power supply.
Cooling Only Heat Pump
Specifications
41 42
FTKC Series FTXM and FTHM Series FTKC25QVMVRKC25QVMV2.5 (1.0-3.4)
8,500(3,400-11,600)
3.2 680 (210-1,100)
5.30FTKC25QVMV
9.0 (318)
38/25/19
RKC25QVMV
500
0.5047/44
23
FTKC35QVMVRKC35QVMV3.5 (1.3-4.1)
11,900 (4,400-14,000)
4.5 960 (250-1,455)
5.50FTKC35QVMV
10.8 (381)
39/26/22
RKC35QVMV
700
0.7049/45
26
FTKC50QVMVRKC50QVMV5.2 (1.4-6.0)
17,700(4,800-20,500)
6.3 1,365 (260-1,730)
6.05FTKC50QVMV
44/35/29
RKC50QVMV
49/43
FTKC60QVMVRKC60QVMV6.0 (1.4-6.7)
20,500(4,800-22,900)
8.0 1,740 (300-2,060)
5.82FTKC60QVMV
45/36/30 295 x 990 x 263
13RKC60QVMV
50/43
FTKC71QVMVRKC71QVMV7.1 (2.1-7.5)
24,200(7,200-25,600)
10.9 2,365 (400-2,550)
5.75FTKC71QVMV
17.3 (611)
46/37/31
RKC71QVMV
1,300
1.0551/46
40
ø15.9
Indoor unitOutdoor unitModel name
Capacity
Power supplyRunning currentPower consumptionCSPF Indoor unitFront panel colourAirflow rateFan speedSound pressure levelsDimensionsMachine weight Outdoor unitCasing colour
Compressor
Refrigerant Sound pressure levelsDimensionsMachine weightOperation range
Piping connection
Max. piping lengthMax. level difference
Rated (Min.-Max.)
Rated
LiquidGas
Drain
kW
Btu/h
AW
m3/min (cfm)
dB (A)mmkg
W
kgdB (A)
mmkg
°CDB
mm
m
Motor output
Charge volumeH/SL
H x W x D
H/L/SLH x W x D
H
Type
Type
FTXM20HVMVRXM20HVMV
2.0 (1.0-2.6)6,800
(3,400-8,850)2.0 (1.0-2.6)
6,800(3,400-8,850)
2.8 2.8
454 (225-645)454 (225-645)
4.90 FTXM20HVMV
9.0 (318)9.0 (318)
39/28/2539/29/27
RXM20HVMV
395
FTXM25HVMVRXM25HVMV
2.5 (1.0-3.4)8,500
(3,400-11,600)2.5 (1.0-3.4)
8,500 (3,400-11,600)
3.0 3.0
610 (225-1,070)610 (225-1,070)
5.80 FTXM25HVMVShiny pure white
9.0 (318)9.0 (318)
40/29/2540/30/27
283 x 770 x 2038
RXM25HVMV
551
0.7548 (H)48 (H)
550 x 658 x 27527
10 to 462 to 20
ø9.5
1512
FTXM35HVMVRXM35HVMV
3.5 (1.2-3.8)11,900
(4,100-12,950)3.5 (1.2-3.8)
11,900 (4,100-12,950)
4.6 4.6
990 (250-1,320)990 (250-1,320)
5.10 FTXM35HVMV
9.7 (342)9.9 (349)
41/30/2641/31/28
RXM35HVMV
913
FTHM50HVMVRHM50HVMV
5.0 (1.6-6.0)17,700
(5,500-20,500)5.0 (1.6-6.0)
17,700 (5,500-20,500)
6.0 6.0
1,315 (350-1,740)1,315 (350-1,740)
6.30 FTHM50HVMV
18.15 (641)15.8 (558)
44/35/2844/35/32
RHM50HVMV
47/4448/45
FTHM60HVMVRHM60HVMV
6.0 (1.6-6.7)20,500
(5,500-22,900)6.0 (1.6-6.7)
20,500 (5,500-22,900)
8.0 8.3
1,740 (360-1,950)1,740 (360-1,950)
5.70 FTHM60HVMV
Shiny white18.3 (646)15.6 (551)
44/36/3044/35/32
295 × 990 × 26313
RHM60HVMV
47/4449/45
595 x 845 x 300
10 to 462 to 20
3020
FTHM71HVMVRHM71HVMV
7.1 (2.1-7.5)24,200
(7,200-25,600)7.1 (2.1-7.5)
24,200 (7,200-25,600)
10.9 10.9
2,370 (700-2,500)2,370 (700-2,500)
5.50 FTHM71HVMV
19.5 (689)16.8 (593)
46/37/3446/37/34
RHM71HVMV
1,300
1.0551/4552/46
39
ø15.9
Indoor unitOutdoor unitModel name
Capacity
Power supply
Running current
Power consumption
CSPFIndoor unitFront panel colour
Airflow rate
Fan speed
Sound pressure levels
DimensionsMachine weight Outdoor unitCasing colour
Compressor
Refrigerant
Sound pressure levels
DimensionsMachine weight
Operation range
Piping connection
Max. piping lengthMax. level difference
Rated (Min.-Max.)
Rated (Min.-Max.)
Rated
Rated (Min.-Max.)
Cooling
Heating
CoolingHeatingCoolingHeating
CoolingHeating
CoolingHeating
CoolingHeating
CoolingHeatingLiquidGas
Drain
kW
Btu/h
kW
Btu/h
A
W
m3/min (cfm)
dB (A)
mmkg
W
kg
dB (A)
mmkg
°CDB°CWB
mm
m
Motor output
Charge volume
H x W x D
H x W x D
H/L/SL
H
H/SL
Type
Type
1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Shiny white
5 steps, quiet and automatic
Ivory whiteHermetically sealed swing type
R-32
19.4 to 46 ø6.4
ø16.0
16.7 (590)
283 x 770 x 2238
550 x 658 x 275
ø9.5
1512
595 x 845 x 300
1,200
1.00
36
ø12.7
3020
1,200
1.00
36
ø12.7
1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
5 steps, quiet and automatic
Ivory whiteHermetically sealed swing type
R-32
ø6.4
ø16.0
95%
Measurement conditions1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.2. Sound pressure levels are based on the temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of
ambient conditions.3. CSPF is based on TCVN 7830: 2012 conditions.
Note: The above values are based on operation with a 220 V, 50 Hz power supply.
Measurement conditions1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.2. Heating capacity is based on: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; piping length 7.5 m. 3. Sound pressure levels are measured in an anechoic chamber based on the temperature condition 1 and 2 above. These values are normally somewhat higher during actual operation as a result of
ambient conditions.4. CSPF is based on TCVN 7830: 2012 conditions.
Note: The above values are based on operation with a 220 V, 50 Hz power supply.
Cooling Only Heat Pump
Options
43 44
Outdoor Unit
Control System
No.12
Item Air direction adjustment grilleDrain plug
Note: *1. One set includes five pieces for five units.
No.1234
Item Central remote controllerUnified On/Off controllerSchedule timerInterface adaptor for DIII-NET use
Note: *1. An interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
*1
*1
*1
FTKV25/35/50/60/71DCS302CA61DCS301BA61DST301BA61KRP928BB2S
KKP937A4
RKV50/60 RKV71
KKP945A4
RKV25/35KPW937A4
Indoor Unit
Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit. *2. The time clock and other devices should be obtained locally. *3. The filter is a standard accessory.
No.12
345
Item 5-room centralised controllerWiring adaptor for time clock/remote controller (Normal open pulse contact/normal open contact)Titanium apatite photocatalytic air-purifying filterRemote controller loss prevention with chainDaikin mobile controller
*1
*2
*3
*1
FTKV25/35/50/60/71KRC72A
KRP413AB1S
KAF970A46KKF910A4
BRP072A42
Outdoor Unit
Control System
No.12
Item Air direction adjustment grilleDrain plug
Note: *1. One set includes five pieces for five units.
No.12345
Item Central remote controllerUnified On/Off controllerSchedule timerInterface adaptor for DIII-NET useRemote control PC-board set
Notes: *1. An interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit. *2. A remote control PC-board set (KRP067A41) is also required for each indoor unit. � *3. A remote control PC-board set (KRP980B2) is also required for each indoor unit.
*1
*1
*1
FTXV50/60/71
KRP928BB2SKRP980B2
FTXV25/35
KRP928BB2SKRP067A41
KKP937A4
RXV50/60/71KPW5E112
RXV25/35KPW937E4
Indoor Unit
Notes: *1. A remote control PC-board set (KRP067A41) is also required for each indoor unit. �*2. A remote control PC-board set (KRP980B2) is also required for each indoor unit. � *3. A three m (BRCW901A03) or eight m (BRCW901A08) length wired remote controller cord is necessary. *4. The time clock and other devices should be obtained locally. *5. The filter is a standard accessory.
No.
1
2
3
4
5678
Item
Wired remote controller
Wired remote controller cord
5-room centralised controllerWiring adaptor for time clock/remote controller (Normal open pulse contact/normal open contact)Titanium apatite photocatalytic air-purifying filterRemote controller loss prevention with chainDaikin mobile controller Remote control PC-board set
BRCW901A03BRCW901A08
KAF970A46KKF910A4
*3
*1
Central remote controllerDCS302CA61
Unified On/Off controllerDCS301BA61
Schedule timerDST301BA61
Drain plugKKP937A4
Titanium apatite photocatalytic air-purifying filterKAF970A46
FTXV50/60/71BRC944B2BRC073A1
KRC72A
KRP413AB1S
BRP072A42KRP980B2
FTXV25/35BRC944B2BRC073A1
KRC72A
KRP413AB1S
BRP072A42KRP067A41
5-room centralised controllerKRC72A
FTKV Series FTXV Series FTXV Series
KPW945A4
Outdoor UnitNo.12
Item Air direction adjustment grilleDrain plug
Note: *1. One set includes five pieces for five units.
KKP937A4
RHM50/60/71KPW937E4
RXM20/25/35KPW937B4
Indoor Unit
Notes: *1. The filter is a standard accessory. �*2. A remote control PC-board set (KRP980B2) is also required for each indoor unit.
No.1234
Item Titanium apatite photocatalytic air-purifying filterRemote controller loss prevention with chainDaikin mobile controller Remote control PC-board set
*1
*1
FTXM20/25/35
KKF917A4––
FTHM50/60/71
KKF910A4BRP072A42KRP980B2
FTXM and FTHM Series
Outdoor UnitNo.1
Item Air direction adjustment grille
RKC50/60/71RKC25/35
Indoor Unit
Notes: *1. The filter is a standard accessory. *2. A remote control PC-board set (KRP067A41) is also required for each indoor unit. *3. A remote control PC-board set (KRP980B2)is also required for each indoor unit.
No.1234
Item Titanium apatite photocatalytic air-purifying filterRemote controller loss prevention with chainDaikin mobile controllerRemote control PC-board set
*1
*2
KAF970A46KKF910A4
KRP067A41BPR072A42 BPR072A42
KRP980B2
FTKC Series
*1
*1
*4
*5
*1
*1
*1
*2
*2
*2
*2
*2
*2 *3
Length 3 m (shielded wire)Length 8 m (shielded wire)
DCS302CA61DCS301BA61DST301BA61
*2
KAF970A46
Cooling Only
Cooling Only
Heat Pump
Heat Pump
FTKC25/35 FTKC50/60/71
Dimensions (H x W x D)Gross weight Standby electricityWireless LAN standardAccessories
Daikin mobile controller BRP072A42
40 g1.2 W or less (adaptor only)IEEE802.11 b/g/n (2.4 GHz)
Wire harness (1,600 mm), screws (two pieces), double-faced tape, installation manual
79 x 52 x 17.5 mm Note:
*1
*1. When using a wireless LAN adaptor, there is continuous transmission between the air conditioner and the adaptor, so the air conditioner will not enter standby electricity saving mode. When the adaptor is connected, the standby electricity consumption of the product is about one Watt.
*2 *3
KPW937E4