12
Split System Heat Pump Product & Performance Data XB 13 4TWB3018-060 1½ – 5 Tons PUB. NO. 22-1793-02

Split System Heat Pump Product & Performance Data

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Split System Heat Pump Product & Performance Data

Split SystemHeat Pump Product& Performance Data

XB 134TWB3018-060

1½ – 5 Tons

PUB. NO. 22-1793-02

Page 2: Split System Heat Pump Product & Performance Data

© 2008 Trane 2 22-1793-02

Features andBenefits

• Climatuff® compressor

• All aluminum Spine Fin™ coil

• Quick-Sess™ cabinet, serviceaccess and refrigerant connectionswith full coil protection

• DuraTuff™ base, fast complete drain,weather proof

• Glossy corrosion resistant finish

• Internal compressor high/low pressureand temperature protection

• 018, 024, 030 and 060 ship with Start Kit

• Liquid line filter-drier

• Polyslate gray cabinet

• Low Pressure Switch

• Demand Defrost Control

• High Pressure Switch

• R-410A refrigerant

• 5 year limited warranty oncompressor, coil and 5 years onparts (Residential Use)

• Extended warranties available

• 100% line run test

• Low ambient cooling to 55°F asshipped

• Low ambient cooling to 30°F withEDC accessory AY28X084 and TXV

Page 3: Split System Heat Pump Product & Performance Data

22-1793-02 3

Contents

Features and Benefits 2

General Data 4Product Specifications 4A-weighted Sound Power Level [dB(A)] 4Accessory Description and Usage 5ARI Standard Capacity Rating Conditions 5

Model Nomenclature 6

Electrical Data 7

Dimensions 10

Mechanical Specification Options 11

Page 4: Split System Heat Pump Product & Performance Data

4 22-1793-02

Product SpecificationsModel No. 1 4TWB3018A1 4TWB3024A1 4TWB3030A1 4TWB3036A1Electrical Data V/Ph/Hz 2 200/230/1/60 200/230/1/60 200/230/1/60 208/230/1/60Min Cir Ampacity 10 12 15 21Max Fuse Size (Amps) 15 20 25 35Compressor CLIMATUFF® CLIMATUFF® CLIMATUFF® CLIMATUFF® - SCROLLRL Amps - LR Amps 7.7 - 38.6 9.4 - 63 11.7 - 68.2 15.4 - 83Outdoor Fan FL Amps 0.7 0.7 0.7 1.3Fan HP 1/8 1/8 1/8 1/4Fan Dia (inches) 23.0 23.0 23.0 27.6Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™Refrigerant R-410A 5/12-LB/OZ 5/12-LB/OZ 6/01-LB/OZ 7/15-LB/OZLine Size - (in.) O.D. Gas 3 1/2 5/8 3/4 3/4Line Size - (in.) O.D. Liquid 3 1/4 5/16 5/16 3/8Charge Spec. Subcooling 10° 11° 11° 10°Dimensions H x W x D (Crated) 34 x 30.1 x 33 34 x 30.1 x 33 42 x 30.1 x 33 42.4 x 35.1 x 38.7Weight - Shipping 221 224 237 277Weight - Net 193 196 209 242Start Components YES YES YES NOSound Enclosure NO NO NO NOCompressor Sump Heat NO YES YES YESOptional Accessories: 4Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501AEvaporator Defrost Control AY28X084 AY28X084 AY28X084 AY28X084Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101Snow Leg-Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002Snow Leg-4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003Extreme Condition Mounting Kit BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT004Start Kit BAYKSKT260Crankcase Heater Kit BAYCCHT300Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103Refrigerant Lineset 5 TAYREFLN5* TAYREFLN6* TAYREFLN2* TAYREFLN7*1 Certified in accordance with the Air-Source Unitary Heat Pump equipment certification program which is based on ARI Standard 210/240.2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line.

For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision)4 For accessory description and usage, see page 5.5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.

GeneralData

A-weighted Sound Power Level [dB(A)]

SOUND POWER A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)]MODEL LEVEL [dB(A)] 63 125 250 500 1000 2000 4000 8000

4TWB3018A1 79 47.3 60.7 65.8 71.2 72.8 72.1 62.2 52.8

4TWB3024A1 81 45.3 58.8 70.5 70.5 75.4 75.3 66.8 61.3

4TWB3030A1 80 46.6 58.2 65.9 69.2 73.5 73.1 62.3 56.5

4TWB3036A1 79 46.4 59.6 67.4 74.8 73.8 68.9 61.2 53.4

4TWB3042A1 80 47.6 58.3 67.3 74.9 74.9 70.4 62.3 53.0

4TWB3048A1 78 47.0 56.5 66.7 73.0 72.8 69.3 62.0 51.4

4TWB3060A1 78 45.3 55.1 66.6 73.0 73.5 69.7 63.1 53.9Note: Tested in accordance with ARI Standard 270.95. (Not listed with ARI)

Page 5: Split System Heat Pump Product & Performance Data

22-1793-02 5

GeneralData

Product SpecificationsModel No. 1 4TWB3042A1 4TWB3048A1 4TWB3060A1Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60Min Cir Ampacity 25 30 36Max Fuse Size (Amps) 40 50 60Compressor CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL CLIMATUFF® - SCROLLRL Amps - LR Amps 18.6 - 105 23.1 - 134 27.6 - 158Outdoor Fan FL Amps 1.3 1.3 1.3Fan HP 1/4 1/4 1/4Fan Dia (inches) 27.6 27.6 27.6Coil Spine Fin™ Spine Fin™ Spine Fin™Refrigerant R-410A 8/03-LB/OZ 8/10-LB/OZ 9/07-LB/OZLine Size - (in.) O.D. Gas 3 3/4 7/8 7/8Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8Charge Spec. Subcooling 10° 10° 13°Dimensions H x W x D (Crated) 42.4 x 35.1 x 38.7 46.4 x 35.1 x 38.7 46.4 x 35.1 x 38.7Weight - Shipping 278 291 314Weight - Net 243 255 278Start Components NO NO YESSound Enclosure NO NO NOCompressor Sump Heat YES YES YESOptional Accessories: 4Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501AEvaporator Defrost Control AY28X084 AY28X084 AY28X084Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101Snow Leg-Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002Snow Leg-4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004Start Kit BAYKSKT260 BAYKSKT260Crankcase Heater KitSeacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103Refrigerant Lineset 5 TAYREFLN7* TAYREFLN3* TAYREFLN3*

ARI Standard Capacity Rating ConditionsARI STANDARD 210/240 RATING CONDITIONS —(A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB

air entering outdoor coil.(B) High Temperature Heating 47°F DB, 43°F WB air entering

outdoor coil, 70°F DB air entering indoor coil.(C) Low Temperature Heating 17°F DB, 15°F WB air entering

outdoor coil, 70°F DB air entering indoor coil.(D) Rated indoor airflow for heating is the same as for cooling.ARI STANDARD 270 RATING CONDITIONS — (Noise ratingnumbers are determined with the unit in cooling operation.)Standard Noise Rating number is at 95°F outdoor air.

Accessory Description and UsageAnti-Short Cycle Timer — Solid state timing device thatprevents compressor recycling until five (5) minutes haveelapsed after satisfying call or power interruptions. Use in areawith questionable power delivery, commercial applications, longlineset, etc.Evaporator Defrost Control — SPST Temperature actuatedswitch that cycles the condenser off as indoor coil reachesfreeze-up conditions. Used for low ambient cooling to 30°Fwith TXV.Rubber Isolators — Five (5) large rubber donuts to isolatecondensing unit from transmitting energy into mounting frameor pad. Use on any application where sound transmissionneeds to be minimized.Hard Start kit — Start capacitor and relay to assist compressormotor startup. Use in areas with marginal power supply, on longlinesets, low ambient conditions, etc.Extreme Condition Mount Kit — Bracket kits to securelymount condensing unit to a frame or pad without removing anypanels. Use in areas with high winds, or on commercial rooftops, etc.

Page 6: Split System Heat Pump Product & Performance Data

6 22-1793-02

ModelNomenclature

Refrigerant Type2 = R-224 = R-410A

TRANE

Product TypeW = Split Heat PumpT = Split Cooling

Product FamilyZ = Leadership – Two StageX = LeadershipR = Replacement/RetailB = BasicA = Light Commercial

Family SEER0 = 10 3 = 13 6 = 161 = 11 4 = 14 8 = 182 = 12 5 = 15 9 = 19

Split System Connections 1-6 Tons0 = Brazed

Nominal Capacity in 000s of BTUs

Major Design Modifications

Power Supply1 = 200-230/1/60 or 208-230/1/603 = 200-230/3/604 = 460/3/60

Secondary Function

Minor Design Modifications

Unit Parts Identifier

Outdoor Units4 T W B 3 0 3 6 A 1 0 0 0 A A

Refrigerant Type4 = R-410A2 = R-22

ApplicationTE = Fully ConvertibleTG = Semi ConvertibleTF = Front ReturnTV = Vertical

Product FamilyE = Leadership – Variable SpeedP = LeadershipC = Replacement/RetailB = Basic

Flow Control3 = Nonbleed TXV4 = FCCV*

Feature Identifier0 = Standard UnitF = Air-Tite™

Nominal Capacity in 000s of BTUs

Major Design Modifications

Power Supply1 = Single Phase

Electrical Connection0 = Pig TailsB = Circuit BreakerD = Pull Disconnect

Future Option – Factory Installed Heater Nominal KW Value

Minor Design Modifications

Unit Parts Identifier

NOTE: There will be a phase-in of new model numbers for new air handlers over next 2 years.*Shipped with R-22 FCCV

Air Handlers –Residential

4 T E E 3 F 3 6 A 1 A A0 0 0

Furnace ConfigurationTU = Upflow / HorizontalTD = Downflow / Horizontal

TypeD = 80% PremiumX = 90% Premium

Number of Heating Stages1 = Single Stage2 = Two Stage3 = Three Stage

Cabinet WidthA = 14.5" Cabinet WidthB = 17.5" Cabinet WidthC = 21.0" Cabinet WidthD = 24.5" Cabinet Width

Heating Input080 = 80,000 BTUH

Major Design Change

Power Supply / Fuel9 = 115 Volts / Natural GasF = 115 Volts / Natural Gas with Integrated ifD Filter

Airflow Capacity for Cooling36 = 3 Ton Standard PSC MotorH3 = 3 Ton High Efficiency MotorV3 = 3 Ton Variable Speed Motor

Draft Inducer Speeds1 = Single Speed2 = Two SpeedV = Variable Speed

Minor Design Change

Service Digit – Not Orderable

T U D 1 B 0 8 0 A 9 H 3 1 A AHigh Efficiency Furnaces

Refrigerant Type2 = R-22 4 = R-410A

Product FamilyT = Premium (Heat Pump or Convertible Coil)C = Standard (Cooling Only)

Coil DesignX = Direct Expansion Evaporator Coil

Product FamilyC = Cased A CoilA = Uncased A CoilF = Cased Horizontal Flat Coil

Coil Width (Cased / Uncased)A = 14.5" / 13.3" C = 21.0" / 19.8" H = 10.5"B = 17.5" / 16.3" D = 24.5" / 23.3"

Refrigerant Line Coupling0 = Brazed

Nominal Capacity in 000s of BTUs

Major Design Change

EfficiencyC = Standard S = Hi Efficiency

Refrigerant Control3 = TXV – Non-Bleed

Coil CircuitryH = Heat PumpC = Cooling Only

Airflow ConfigurationA = Upflow OnlyU = Upflow / DownflowH = Horizontal OnlyC = Convertible – Upflow, Downflow, Left AirflowM = Convertible – Upflow, Downflow, Left or Right Airflow

Minor Design Change

Unit Parts Identifier

Heat Pump /Cooling Coils

2 T X C B 0 3 6 A C 3 H C A A

Page 7: Split System Heat Pump Product & Performance Data

22-1793-02 7

4TWB3018A 4TWB3024,030A

ElectricalData

SCHEMATIC DIAGRAMS(SEE LEGEND)

Page 8: Split System Heat Pump Product & Performance Data

8 22-1793-02

4TWB3036,042A 4TWB3048A

ElectricalData

SCHEMATIC DIAGRAMS(SEE LEGEND)

Page 9: Split System Heat Pump Product & Performance Data

22-1793-02 9

SYMBOLS

ElectricalData

SCHEMATIC DIAGRAMS

LEGEND4TWB3060A

Page 10: Split System Heat Pump Product & Performance Data

10 22-1793-02

SLEDOM ESAB .GIF A B C D E F G H J K

A8103BWT4 3 2 )4/3-82(037 )8/5-23(928 )4/3-92(657 2/1 4/1 )5(721 )3(67 )4/3-7(791 )4/1-2(75 )02(805

A4203BWT4 3 2 )4/3-82(037 )8/5-23(928 )4/3-92(657 8/5 61/5 )5(721 )3(67 )4/3-7(791 )4/1-2(75 )02(805

A0303BWT4 3 1 )4/3-63(339 )8/5-23(928 )4/3-92(657 4/3 61/5 )8/5-5(341 )8/5-3(29 )4/1-8(012 )8/1-3(97 )02(805

A6303BWT4 4 1 )8/1-73(349 )4/1-73(649 )4/1-43(078 4/3 8/3 )6(251 )8/7-3(89 )8/5-8(912 )8/3-3(68 )02(805

A2403BWT4 4 1 )8/1-73(349 )4/1-73(649 )4/1-43(078 4/3 8/3 )6(251 )8/7-3(89 )8/5-8(912 )8/3-3(68 )02(805

A8403BWT4 4 1 )8/1-14(5401 )4/1-73(649 )4/1-43(078 8/7 8/3 )6(251 )8/7-3(89 )8/5-8(912 )8/3-3(68 )02(805

A0603BWT4 4 1 )8/1-14(5401 )4/1-73(649 )4/1-43(078 8/7 8/3 )6(251 )8/7-3(89 )8/5-8(912 )8/3-3(68 )02(805

Dimensions

4TWB3 OUTLINE DRAWINGNOTE: ALL DIMENSIONS ARE IN MM (INCHES)

Fro

m D

wg.

21D

1530

74 R

ev. 1

3

Page 11: Split System Heat Pump Product & Performance Data

22-1793-02 11

MechanicalSpecification Options

GeneralThe 4TWB3 is fully charged from thefactory for up to 15 feet of piping. Thisunit is designed to operate at outdoorambient temperatures as high as 115°F.Cooling capacities are matched with awide selection of air handlers andfurnace coils that are ARI certified. Theunit is UL listed. Exterior is designed foroutdoor application.

CasingUnit casing is constructed of heavygauge, G90 galvanized steel and paintedwith a weather-resistant powder paint onall louvers, panels, prepaint on all otherpanels. Corrosion and weatherproofCMBP-G30 DuraTuff™ base.

Refrigerant ControlsRefrigeration system controls includecondenser fan, compressor contactorand high pressure switch. High and lowpressure controls are inherent to thecompressor. A factory installed liquid linedrier is standard.

CompressorThe Climatuff® compressor features a5 year limited warranty, internal overtemperature and pressure protectionand total dipped hermetic motor. Otherfeatures include: roto lock suction anddischarge refrigerant connections,centrifugal oil pump and low vibrationand noise.

Condenser CoilThe outdoor coil provides low airflowresistance and efficient heat transfer.The coil is protected on all four sidesby louvered panels and has a 5 yearlimited warranty.

Low Ambient CoolingAs manufactured, this unit has a coolingcapability to 55°F. The addition of anevaporator defrost control permitsoperation to 40°F. The addition of anevaporator defrost control with TXVpermits low ambient cooling to 30°F.

AccessoriesThermostats — Cooling only and heat/cooling (manual and automatic change-over). Sub-base to match thermostat andlocking thermostat cover.

Evaporator Defrost Control — See LowAmbient Cooling.

Page 12: Split System Heat Pump Product & Performance Data

06/08

Trane has a policy of continuous product and product data improvement and it reserves the right to changedesign and specifications without notice.