10
www.habia.com world class solutions Speedflex Speedflex Section I Issue 2 Page Name Impedance Overall diameter (mm) Overall diameter (in) I.2 Speedflex 142 50 Ohm 5,10 0,200” I.3 Speedflex 179 75 Ohm 2,60 0,102” I.4 Speedflex 295 50 Ohm 5,10 0,200” I.5 Speedflex 316 50 Ohm 2,70 0,106” I.6 Speedflex 316d 50 Ohm 3,10 0,122” I.7 Speedflex 375 50 Ohm 5,70 0,224” I.8 Speedflex 393 50 Ohm 10,10 0,397” I.9 Speedflex 400 50 Ohm 5,10 0,200” I.10 Speedflex 585 50 Ohm 9,00 0,354”

Speed Flex

Embed Size (px)

Citation preview

Page 1: Speed Flex

www.habia.com world class solutions

SpeedflexSp

eedf

lex

Section I Issue 2

Page Name Impedance Overall diameter (mm) Overall diameter (in)I.2 Speedflex 142 50 Ohm 5,10 0,200”I.3 Speedflex 179 75 Ohm 2,60 0,102”I.4 Speedflex 295 50 Ohm 5,10 0,200”I.5 Speedflex 316 50 Ohm 2,70 0,106”I.6 Speedflex 316d 50 Ohm 3,10 0,122”I.7 Speedflex 375 50 Ohm 5,70 0,224”I.8 Speedflex 393 50 Ohm 10,10 0,397”I.9 Speedflex 400 50 Ohm 5,10 0,200”I.10 Speedflex 585 50 Ohm 9,00 0,354”

Page 2: Speed Flex

www.habia.com world class solutions

Alternatives: Construction:ConductorDielectricBraidJacketWeightTemperature rating (°C)Order reference

Notes:All dimensions nominal (± 4%)unless otherwise stated.All dimensions in mm.

Electrical: AttenuationImpedance MHz dB/100mCapacitance 100Velocity of signal propagation 200Signal delay 400Working voltage, AC r.m.s. 900Working voltage, DC 1200Attenuation, typical values 1500(nominal values at an air temperature of +20°C) 1800Power, typical values 2000(ambient temperature of 40°C at sea level and VSWR 1.0) 2500Suitable for frequenciesShielding effectiveness

Environmental & Mechanical: Average PowerMinimum bend radius (MBR) single bend (installation) MHz WMinimum bend radius (MBR) dynamic use 100Flame resistance 200Flammability 400Halogen free 900Smoke generation 1200Connectors 1500

180020002500

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publication and is subject to change without prior notice.

1

2

3

4

5

6

7

8

9

10

11

12

2I

Standard RG 142 B/U: Solid silver plated copper 0,9430000-142-00 Low-foamed PE 2,95

2x Silver plated copper (0,13) 4,10Speedflex 142 UL 1375: HFS 80 T, Black 5,1034000-142-01 56 kg/km

-25 / +80°CSpeedflex 142 XL: 34000-142-0034000-142-03

Alternative colours alsoavailable

50 ± 2 Ohms95 pF/m 100 15

70 % 200 214.7 ns/m 400 32

1600 max 900 513200 max 1200 61see table 1500 69

1800 78see table 2000 83

2500 95up to 3 GHz

-60 dB/m

single bend: 25mmmultiple bends: 50mm 100 269

passes IEC 60332-1 200 189passes UL 1581 VW-1 400 133

passes IEC 60754-2 900 90passes IEC 61034-2 1200 73

compatible with all standard types 1500 651800 602000 552500 50

Ref: SX-eSX142-03Date: 2008-03-20Approved by:

Speedflex 142LS0H Coaxial

®

Page 3: Speed Flex

www.habia.com world class solutions

Alternatives: Construction:ConductorDielectricBraidJacketWeightTemperature rating (°C)Order reference

Notes:All dimensions nominal (± 4%)unless otherwise stated.All dimensions in mm.

Electrical: AttenuationImpedance MHz dB/100mCapacitance 100Velocity of signal propagation 200Signal delay 400Working voltage, AC r.m.s. 900Working voltage, DC 1200Attenuation, typical values 1500(nominal values at an air temperature of +20°C) 1800Power, typical values 2000(ambient temperature of 40°C at sea level and VSWR 1.0) 2500Suitable for frequenciesShielding effectiveness

Environmental & Mechanical: Average PowerMinimum bend radius (MBR) single bend (installation) MHz WMinimum bend radius (MBR) dynamic use 100Flame resistance 200Flammability 400Halogen free 900Smoke generation 1200Connectors 1500

180020002500

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publication and is subject to change without prior notice.

1

2

3

4

5

6

7

8

9

10

11

12

3I

Speedflex 179LS0H Coaxial

Standard RG 179 B/U: Silver plated copper covered steel (7x0,10) 0,3030000-179-00 Low-foamed PE 1,60

Silver plated copper (0,10) 2,05Speedflex 179 UL 1375: HFS 80 T, Black 2,6034000-179-01 12 kg/km

-25 / +80°CSpeedflex 179 XL: 34000-179-0034000-179-03

Alternative colours alsoavailable

75 ± 3 Ohms64 pF/m 100 24

70 % 200 344.7 ns/m 400 48900 max 900 72

1800 max 1200 83see table 1500 93

1800 105see table 2000 112

2500 127up to 2,5 GHz

-60 dB/m

single bend: 8mmmultiple bends: 30mm 100 73

passes IEC 60332-1 200 52passes UL 1581 VW-1 400 37

passes IEC 60754-2 900 25passes IEC 61034-2 1200 22

compatible with all standard types 1500 201800 162000 152500 13

®

Ref: SX-eSX179-03Date: 2008-03-20Approved by:

Page 4: Speed Flex

www.habia.com world class solutions

Alternatives: Construction:ConductorDielectricBraidJacketWeightTemperature rating (°C)Order reference

Notes:All dimensions nominal (± 4%)unless otherwise stated.All dimensions in mm.

Electrical: AttenuationImpedance MHz dB/100mCapacitance 100Velocity of signal propagation 200Signal delay 400Working voltage, AC r.m.s. 900Working voltage, DC 1200Attenuation, typical values 1500(nominal values at an air temperature of +20°C) 1800Power, typical values 2000(ambient temperature of 40°C at sea level and VSWR 1.0) 2500Suitable for frequenciesShielding effectiveness

Environmental & Mechanical: Average PowerMinimum bend radius (MBR) single bend (installation) MHz WMinimum bend radius (MBR) dynamic use 100Flame resistance 200Flammability 400Halogen free 900Smoke generation 1200Connectors 1500

180020002500

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publication and is subject to change without prior notice.

1

2

3

4

5

6

7

8

9

10

11

12

4I

Speedflex 295 UL 1375: Solid silver plated copper 1,1234000-295-01 High-foamed PE 2,95

2x Silver plated copper (0,13) 4,10Alternative colours also HFS 80 T, Black 5,10available 54 kg/km

-25 / +80°C34000-295-00

50 ± 2 Ohms82 pF/m 100 11

82 % 200 164 ns/m 400 23

400 max 900 36800 max 1200 42see table 1500 48

1800 53see table 2000 57

2500 65up to 2,5 GHz

-60 dB/m

single bend: 25mmmultiple bends: 75mm 100 282

passes IEC 60332-1 200 194passes UL 1581 VW-1 400 133

passes IEC 60754-2 900 85passes IEC 61034-2 1200 73

please ask for details 1500 651800 602000 552500 50

Ref: SX-eSX295-03Date: 2008-03-20Approved by:

Speedflex 295LS0H Coaxial

®

Page 5: Speed Flex

www.habia.com world class solutions

Alternatives: Construction:ConductorDielectricBraidJacketWeightTemperature rating (°C)Order reference

Notes:All dimensions nominal (± 4%)unless otherwise stated.All dimensions in mm.

Electrical: AttenuationImpedance MHz dB/100mCapacitance 100Velocity of signal propagation 200Signal delay 400Working voltage, AC r.m.s. 900Working voltage, DC 1200Attenuation, typical values 1500(nominal values at an air temperature of +20°C) 1800Power, typical values 2000(ambient temperature of 40°C at sea level and VSWR 1.0) 2500Suitable for frequenciesShielding effectiveness

Environmental & Mechanical: Average PowerMinimum bend radius (MBR) single bend (installation) MHz WMinimum bend radius (MBR) dynamic use 100Flame resistance 200Flammability 400Halogen free 900Smoke generation 1200Connectors 1500

180020002500

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publication and is subject to change without prior notice.

1

2

3

4

5

6

7

8

9

10

11

12

5I

Speedflex 316LS0H Coaxial

Standard RG 316 /U: Silver plated copper (7x0,17) 0,5430000-316-00 Low-foamed PE 1,52

Silver plated copper (0,10) 2,00Speedflex 316 UL 1375: HFS 80 T, Black 2,7034000-316-01 13 kg/km

-25 / +80°CSpeedflex 316 XL: 34000-316-0034000-316-03

Alternative colours alsoavailable

50 ± 2 Ohms95 pF/m 100 26

70 % 200 384.7 ns/m 400 53

1000 max 900 832000 max 1200 100see table 1500 113

1800 126see table 2000 135

2500 152up to 2,5 GHz

-60 dB/m

single bend: 9mmmultiple bends: 30mm 100 86

passes IEC 60332-1 200 58passes UL 1581 VW-1 400 42

passes IEC 60754-2 900 30passes IEC 61034-2 1200 23

compatible with all standard types 1500 211800 192000 182500 15

®

Ref: SX-eSX316-03Date: 2008-03-20Approved by:

Page 6: Speed Flex

www.habia.com world class solutions

Alternatives: Construction:ConductorDielectricBraidJacketWeightTemperature rating (°C)Order reference

Notes:All dimensions nominal (± 4%)unless otherwise stated.All dimensions in mm.

Electrical: AttenuationImpedance MHz dB/100mCapacitance 100Velocity of signal propagation 200Signal delay 400Working voltage, AC r.m.s. 900Working voltage, DC 1200Attenuation, typical values 1500(nominal values at an air temperature of +20°C) 1800Power, typical values 2000(ambient temperature of 40°C at sea level and VSWR 1.0) 2500Suitable for frequenciesShielding effectiveness

Environmental & Mechanical: Average PowerMinimum bend radius (MBR) single bend (installation) MHz WMinimum bend radius (MBR) dynamic use 100Flame resistance 200Flammability 400Halogen free 900Smoke generation 1200Connectors 1500

180020002500

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publication and is subject to change without prior notice.

1

2

3

4

5

6

7

8

9

10

11

12

6I

Standard RGD 316 : Silver plated copper (7x0,17) 0,5430000-316-05 Low-foamed PE 1,52

2x Silver plated copper (0,10) 2,45Speedflex 316d UL 1375: HFS 80 T, Black 3,1034000-316-11 20 kg/km

-25 / +80°CSpeedflex 316d XL: 34000-316-1034000-316-13

Alternative colours alsoavailable

50 ± 2 Ohms94 pF/m 100 26

70 % 200 384.7 ns/m 400 53

1000 max 900 832000 max 1200 100see table 1500 113

1800 126see table 2000 135

2500 152up to 2,5 GHz

-60 dB/m

single bend: 9mmmultiple bends: 30mm 100 86

passes IEC 60332-1 200 58passes UL 1581 VW-1 400 42

passes IEC 60754-2 900 30passes IEC 61034-2 1200 23

compatible with all standard types 1500 211800 192000 182500 15

Ref: SX-eSX316d-03Date: 2008-03-20Approved by:

Speedflex 316dLS0H Coaxial

®

Page 7: Speed Flex

www.habia.com world class solutions

Alternatives: Construction:ConductorDielectricBraidJacketWeightTemperature rating (°C)Order reference

Notes:All dimensions nominal (± 4%)unless otherwise stated.All dimensions in mm.

Electrical: AttenuationImpedance MHz dB/100mCapacitance 100Velocity of signal propagation 200Signal delay 400Working voltage, AC r.m.s. 900Working voltage, DC 1200Attenuation, typical values 1500(nominal values at an air temperature of +20°C) 1800Power, typical values 2000(ambient temperature of 40°C at sea level and VSWR 1.0) 2500Suitable for frequenciesShielding effectiveness

Environmental & Mechanical: Average PowerMinimum bend radius (MBR) single bend (installation) MHz WMinimum bend radius (MBR) dynamic use 100Flame resistance 200Flammability 400Halogen free 900Smoke generation 1200Connectors 1500

180020002500

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publication and is subject to change without prior notice.

1

2

3

4

5

6

7

8

9

10

11

12

7I

Speedflex 375LS0H Coaxial

Speedflex 375 UL 1375: Solid silver plated copper 1,4034000-375-01 High-foamed PE 3,75

2x Silver plated copper (0,10) 4,70Alternative colours also HFS 80 T, Black 5,70available 64 kg/km

-25 / +80°C34000-375-00

50 ± 2 Ohms82 pF/m 100 9

82 % 200 134 ns/m 400 18

500 max 900 291000 max 1200 34see table 1500 38.5

1800 42.5see table 2000 46

2500 52up to 2,5 GHz

-60 dB/m

single bend: 29mmmultiple bends: 85mm 100 374

passes IEC 60332-1 200 262passes UL 1581 VW-1 400 175

passes IEC 60754-2 900 110passes IEC 61034-2 1200 95

please ask for details 1500 851800 752000 702500 60

®

Ref: SX-eSX375-03Date: 2008-03-20Approved by:

Page 8: Speed Flex

www.habia.com world class solutions

Alternatives: Construction:ConductorDielectricBraidJacketWeightTemperature rating (°C)Order reference

Notes:All dimensions nominal (± 4%)unless otherwise stated.All dimensions in mm.

Electrical: AttenuationImpedance MHz dB/100mCapacitance 100Velocity of signal propagation 200Signal delay 400Working voltage, AC r.m.s. 900Working voltage, DC 1200Attenuation, typical values 1500(nominal values at an air temperature of +20°C) 1800Power, typical values 2000(ambient temperature of 40°C at sea level and VSWR 1.0) 2500Suitable for frequenciesShielding effectiveness

Environmental & Mechanical: Average PowerMinimum bend radius (MBR) single bend (installation) MHz WMinimum bend radius (MBR) dynamic use 100Flame resistance 200Flammability 400Halogen free 900Smoke generation 1200Connectors 1500

180020002500

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publication and is subject to change without prior notice.

1

2

3

4

5

6

7

8

9

10

11

12

8I

Standard RG 393 /U: Silver plated copper (7x0,80) 2,4330000-393-00 Low-foamed PE 7,24

2x Silver plated copper (0,16) 8,70Speedflex 393 UL 1375: HFS 80 T, Black 10,1034000-393-01 180 kg/km

-25 / +80°CSpeedflex 393 XL: 34000-393-0034000-393-03

Alternative colours alsoavailable

50 ± 2 Ohms95 pF/m 100 8

70 % 200 124.7 ns/m 400 16

4400 max 900 268800 max 1200 30see table 1500 34

1800 38see table 2000 41

2500 50up to 2,5 GHz

-60 dB/m

single bend: 50mmmultiple bends: 180m 100 857passes IEC 60332-1 200 598

passes UL 1581 VW-1 400 414passes IEC 60754-2 900 265passes IEC 61034-2 1200 224

compatible with all standard types 1500 2001800 1802000 1702500 150

Ref: SX-eSX393-03Date: 2008-03-20Approved by:

Speedflex 393LS0H Coaxial

®

Page 9: Speed Flex

www.habia.com world class solutions

Alternatives: Construction:ConductorDielectricBraidJacketWeightTemperature rating (°C)Order reference

Notes:All dimensions nominal (± 4%)unless otherwise stated.All dimensions in mm.

Electrical: AttenuationImpedance MHz dB/100mCapacitance 100Velocity of signal propagation 200Signal delay 400Working voltage, AC r.m.s. 900Working voltage, DC 1200Attenuation, typical values 1500(nominal values at an air temperature of +20°C) 1800Power, typical values 2000(ambient temperature of 40°C at sea level and VSWR 1.0) 2500Suitable for frequenciesShielding effectiveness

Environmental & Mechanical: Average PowerMinimum bend radius (MBR) single bend (installation) MHz WMinimum bend radius (MBR) dynamic use 100Flame resistance 200Flammability 400Halogen free 900Smoke generation 1200Connectors 1500

180020002500

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publication and is subject to change without prior notice.

1

2

3

4

5

6

7

8

9

10

11

12

9I

Speedflex 400LS0H Coaxial

Standard RG 400 /U: Silver plated copper (19x0,20) 0,9830000-400-00 Low-foamed PE 2,95

2x Silver plated copper (0,13) 4,10Speedflex 400 UL 1375: HFS 80 T, Black 5,1034000-400-01 55 kg/km

-25 / +80°CSpeedflex 400 XL: 34000-400-0034000-400-03

Alternative colours alsoavailable

50 ± 2 Ohms95 pF/m 100 16

70 % 200 234.7 ns/m 400 33

1500 max 900 533000 max 1200 63see table 1500 71

1800 79see table 2000 84

2500 96up to 2,5 GHz

-60 dB/m

single bend: 25mmmultiple bends: 50mm 100 245

passes IEC 60332-1 200 173passes UL 1581 VW-1 400 122

passes IEC 60754-2 900 80passes IEC 61034-2 1200 67

compatible with all standard types 1500 601800 552000 502500 45

®

Ref: SX-eSX400-03Date: 2008-03-20Approved by:

Page 10: Speed Flex

www.habia.com world class solutions

Alternatives: Construction:ConductorDielectricBraidJacketWeightTemperature rating (°C)Order reference

Notes:All dimensions nominal (± 4%)unless otherwise stated.All dimensions in mm.

Electrical: AttenuationImpedance MHz dB/100mCapacitance 100Velocity of signal propagation 200Signal delay 400Working voltage, AC r.m.s. 900Working voltage, DC 1200Attenuation, typical values 1500(nominal values at an air temperature of +20°C) 1800Power, typical values 2000(ambient temperature of 40°C at sea level and VSWR 1.0) 2500Suitable for frequenciesShielding effectiveness

Environmental & Mechanical: Average PowerMinimum bend radius (MBR) single bend (installation) MHz WMinimum bend radius (MBR) dynamic use 100Flame resistance 200Flammability 400Halogen free 900Smoke generation 1200Connectors 1500

180020002500

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publication and is subject to change without prior notice.

1

2

3

4

5

6

7

8

9

10

11

12

10I

Speedflex 585 UL 1375: Solid silver plated copper 2,2234000-585-01 High-foamed PE 5,85

2x Silver plated copper (0,16) 7,25Speedflex 585 XL: HFS 80 T, Black 9,0034000-585-02 144 kg/km

-25 / +80°CAlternative colours also 34000-585-00available

50 ± 2 Ohms82 pF/m 100 7

82 % 200 94 ns/m 400 14

750 max 900 211500 max 1200 25see table 1500 29

1800 33see table 2000 36

2500 42up to 2,5 GHz

-60 dB/m

single bend: 45mmmultiple bends: 135mm 100 698

passes IEC 60332-1 200 477passes UL 1581 VW-1 400 318

passes IEC 60754-2 900 195passes IEC 61034-2 1200 157

please ask for details 1500 1401800 1252000 1152500 100

Ref: SX-eSX585-03Date: 2008-03-20Approved by:

Speedflex 585LS0H Coaxial

®