Technical Specifications400kVA Prime Rated
Generator
Technical Specifications
TENDER FOR SUPPLY, INSTALLATION AND COMMISSIONING OF400 k VA (PRIME), AMF TYPE GENERATOR AND ACCESSORY EQUIPMENT
ItemNo
Item Description Specification CompliedYes/No
Remarks
1. Make of Engine/country of Origin _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
(Contactor to specify)
2. Model of Engine_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
(Contactor to specify)
3. Make of Alternator
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _(Contactor to specify)4. Model of Alternator
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _(Contactor to specify)
5. General Shall be of shipped and delivered to site as complete unitassembled in manufacturers facility
Yes/No
Shall be the exclusive agent for the generator unit offered andmay be responsible for after sales service
Yes/No
Generator control panel shall be from the same generatormanufacturer and shall be shipped assembled/wired at themanufacturers facility
Yes/No
All component and accessories for complete generatorinstallation shall be supplied and installed by the bidder
Yes/No
Page 1 of 10
8/9/2019 Specifications Sakya Generator
2/10
Technical Specifications400kVA Prime Rated
Generator
ItemNo
Item Description Specification CompliedYes/No
Remarks
Price shall include testing and commissioning of the complete
unit including load testing.
Yes/No
Price shall include testing and commissioning of the completeunit including load testing. Necessary loads and fuel shall besupplied by the bidder without any cost to the client.
Yes/No
Contractor shall investigate the site conditions, drawings andspecifications for selecting the most suitable solution for theproposed location.
Yes/No
All documents, drawings, catalogues, instructions, etc.,
relating to this bid shall be in English and in SI Units.
Yes/No
Generator Unit and associated equipment shall be designedfor operation in the following environment conditions:Ambient Temperature : 6 deg. C to 42 deg. CRelative humidity : 90%, non condensing
Yes/No
All documents, drawings, catalogues, instructions, etc.,relating to this bid shall be in English and in SI Units.
Yes/No
6. Rating Shall be of Power output of 400kVA, (Prime) or higher at 0.8power factor
Yes/No
Shall be of Self Excited, 50Hz, 1500rpm, 3 phase, 400/230V Yes/No
Page 2 of 10
8/9/2019 Specifications Sakya Generator
3/10
Technical Specifications400kVA Prime Rated
Generator
ItemNo
Item Description Specification CompliedYes/No
Remarks
7. Scope Supply, installation, testing and commissioning of generator
unit complete with Deisel Engine, Alternator, and all otherequipment for fully operational unit.
Yes/No
Shall be with digital protection and control panel, mounted onthe Unit, wired and tested at the manufacturers facility
Yes/No
Shall be with unit mounted fuel tank with capacity not lessthan 750 liters. Please indicate the capacity.
Yes/No Capacity :
Shall be supplied and installed with bulk fuel tank of capacitynot less than 2500 liters with level indicator, filling pipe
connections. Please indicate the capacity.
Yes/No Capacity :
Shall be supplied and installed with sound attenuationenclosure including unit cooling ductwork. Maximum allowablesound level at 1m distance shall not be more than 75dB.
Yes/No
Shall include with the proposal a detail proposal of soundattenuation enclosure and cooling duct work, including adrawing.
Yes/No
Shall provide necessary cabling and connections fromgenerator panel to ATS panel including conduiting,terminations, and accessories.
Yes/No
Shall provide and supplied with start up battery, battery rack,cabling & connections, battery charger, complete.
Yes/No
Page 3 of 10
8/9/2019 Specifications Sakya Generator
4/10
Technical Specifications400kVA Prime Rated
Generator
ItemNo
Item Description Specification CompliedYes/No
Remarks
8. Features Shall be delivered as Complete System Designed and built at
ISO 9001 Certified manufacturing facility
Yes/No
Shall be factory tested to design specifications at full loadcondition and certified test report submitted
Yes/No
9. Engine Shall be of Industrial water cooled diesel engine Yes / No
Shall be with Electronic Governor and with Electronic Speedcontrol
Yes / No
Start up electrical system shall be 12V dc or 24V dc complete
with Battery Rack & cabling
Yes / No
Air filter shall be of dry type Yes / No
Fuel and oil filter shall be of Cartridge type Yes / No
Shall be with engine cooling system with coolant drain valve Yes / No
10. Alternator Shall be of revolving field single bearing brushless typealternator and Insulation shall be of class H
Yes / No
Shall be of drip proof generator enclosure with cooling airintake (IP 23)
Yes / No
Electrical design shall be in Accordance with BS 5000 part 99 Yes / No
Shall be with in-built heaters and provided with space heaters Yes / No
Page 4 of 10
8/9/2019 Specifications Sakya Generator
5/10
Technical Specifications400kVA Prime Rated
Generator
ItemNo
Item Description Specification CompliedYes/No
Remarks
11. Control panel Shall be with sheet steel enclosure with hinged lockable door
fitted to the generator body with vibration isolators
Yes / No
Standard control panel shall contain instrument, Protection,Indicators and controls indicated below:
Yes / No
12. Control & Display Functions
General
Automatic Voltage Regulation Yes / NoElectronic governor Control Yes / No
Faulty condition / fault history indicator Yes / NoGlow plug control Yes / No
Operator control Interface Functions/Features
Manual/Automatic Mode Selector Switch Yes / NoManual start/stop Switch Yes / NoEmergency Stop Press Button Yes / NoManual/Auto LED Indicators Yes / NoCommon Shutdown LED Yes / NoCommon Warning LED Yes / NoEmergency Stop LED Yes / NoAlphanumeric LED Screen display Yes / NoFault Reset function Yes / No
Page 5 of 10
8/9/2019 Specifications Sakya Generator
6/10
Technical Specifications400kVA Prime Rated
Generator
ItemNo
Item Description Specification CompliedYes/No
Remarks
Measurements and Indicators
EngineLubricating Oil Pressure Yes / NoLubricating Oil Temperature Yes / NoCooling Water Temperature Yes / NoEngine Speed Yes / NoHour meter indication Yes / NoNumber of starts Yes / NoStart up battery voltage Yes / NoBattery Charging Ammeter Yes / No
AlternatorLine to line voltage, Line to neutral voltage Yes / NoFrequency Yes / NoLine current with line selector Yes / NokWh meter, per phase and total Yes / NokVA meter, per phase and total Yes / NoPower factor per phase and total Yes / No
Page 6 of 10
8/9/2019 Specifications Sakya Generator
7/10
Technical Specifications400kVA Prime Rated
Generator
ItemNo
Item Description Specification CompliedYes/No
Remarks
13. Protection & protection Shutdown Function
Shutdown Protection
Engine
Low Fuel Level Trip Yes / NoHigh Fuel Level Trip Yes / NoLow Oil Pressure Trip Yes / NoHigh Engine Cooling WaterTemperature Trip Yes / NoOver speed Trip Yes / No
Alternator
Under & Over Voltage Trip Yes / NoUnder & Over Frequency Trip Yes / NoOver Current Trip Yes / NoEarth Leakage Trip Yes / NoReverse Power Trip Yes / NoReverse AVr Trip Yes / No
Page 7 of 10
8/9/2019 Specifications Sakya Generator
8/10
Technical Specifications400kVA Prime Rated
Generator
ItemNo
Item Description Specification CompliedYes/No
Remarks
14. Protection Shutdown Indication
Shutdown Protection & Indicatoion
Engine
Low Fuel Level Trip Indication Yes / NoHigh Fuel Level Trip Indication Yes / NoLow Oil Pressure Trip Indication Yes / NoHigh Engine Coolant Temperature Trip Indication Yes / NoOver speed Trip Indication Yes / NoFail to Crank Shutdown Indication Yes / No
Over Crank Indication Yes / No
Alternator
Under & Over Voltage Trip Indication Yes / NoUnder & Over Frequency Trip Indication Yes / NoOver Current Trip indication Yes / NoEarth Leakage Trip Indication Yes / NoReverse Power Trip indication Yes / NoReverse AVr Trip Indication Yes / No
Page 8 of 10
8/9/2019 Specifications Sakya Generator
9/10
Technical Specifications400kVA Prime Rated
Generator
ItemNo
Item Description Specification CompliedYes/No
Remarks
15. Generator breaker, Power and Earth Connections
50 kA, 630A, minimum, 4 poleEFR Tripping current to be adjustable from 0-300mA
Yes / No
Power connection from generator Panel to ATS (only the ATSsupplied by others)
Yes / No
Ear thing of Generator Unit (Generator Neutral with CopperRod and Tap, 25mm X 3mm Connection)
Yes / No
16. Mounting Arrangement
Heavy duty fabricated steel base with lifting points and Antivibration pads to ensure vibration isolation
Yes / No
Engine coupled to generator with flexible disc coupling or asper manufacturers standard design
Yes / No
17. Exhaust System and Cooling Air System
Heavy duty industrial capacity exhaust silencer(Heat resisting materials shall be covered with Aluminiumcladding)
Yes / No
Necessary extention of exhaust discharge system Yes / No
Cooling air system complete with hot air discharge system Yes / No
Page 9 of 10
8/9/2019 Specifications Sakya Generator
10/10
Technical Specifications400kVA Prime Rated
Generator
ItemNo
Item Description Specification CompliedYes/No
Remarks
18. Literature
Manufacturers technical literature for engine Yes / No
Manufacturers technical literature for alternator Yes / No
Circuit Diagram for generator control panel Yes / No
19. Warranty
3 years comprehensive,(Parts, Labour and Transport)
Yes / No
3 Nos. free service including oil, filters and labour
Draft service and maintenance agreement after completion of3 year warranty period
Yes / No