Spec StoppersSpec StoppersSweet SpotsSweet Spots
SpecialsSpecials
1
How To Make $6,000How To Make $6,000 MOREMORE on a 26 ton on a 26 ton
Data Aire Series DX UnitData Aire Series DX Unit
2
3
● Increase Liebert Cost
● Reduce Data Aire Cost
● Liebert can still be basis of design
Specification Control = $$$
4
Spec Stopper
● Locking Disconnect Switch
– Standard option with Data Aire
– Liebert charges about $50 more than Data Aire
• Liebert standard is non-locking disconnect
5
Justification
● Locking Disconnect Switch
– Safety
• Locking disconnect can be locked in the off position preventing accidental power up of the unit while it is being serviced
6
Spec Stopper
● Dual Float Condensate Pump with Alarm
– Standard option with Data Aire
– Liebert charges about $60 more than Data Aire
• Liebert standard is single float no alarm
7
Justification
● Dual Float Condensate Pump with Alarm
– Provides an alarm if condensate pump fails
– Alerts operator before water is under floor
8
Spec Stopper
● Fire Stat
– Standard with Data Aire
– Liebert charges about $75
• Liebert standard is no firestat
9
Justification
● Fire Stat
– Responds to heat not smoke
– Required by some codes
10
Spec Stopper
● Crankcase heaters
– Standard with Data Aire
– Liebert charges about $125
11
Justification
● Crankcase heaters
– Prevents refrigerant from diluting compressor oil
– Extends compressor life
12
Spec Stopper
● Steam Generator Humidifier
– Standard with Data Aire
– Liebert charges about $350
13
Justification
● Steam Generator Humidifier– Capacity
• 36% higher capacity than infrared
– Efficiency• 22% more efficient than infrared
– Maintenance• Five minutes to replace canister
– Indoor Air Quality• Enclosed water reservoir heated to boiling
Spec Stopper
● Minimum 18 gauge panels
– Standard with Data Aire
– Liebert standard is 20 gauge
• 18 gauge not available
• Charge about $550 for 16 gauge panels
14
Justification
● Minimum 18 gauge panels
– Superior sound attenuation
15
Spec Stopper
● R-407c Refrigerant
– No added cost with Data Aire
– Liebert charges about $ 750
16
Spec Stopper
● R-407c Refrigerant
– Environmentally friendly
17
Liebert Data Aire
Non-Locking Disconnect $ 50 0
Dual Float Condensate Pump $ 60 0
Firestat $ 75 0
Crankcase Heaters $ 125 0
Steam Generator $ 350 0
18 Gauge Panels $ 550 0
R-407C $ 750 0
Total Increase in Cost $1,960 0
Specification Control = $$$
18
19
Spec Stopper (Ceiling Units)
● Belt Drive Fans
– Standard with Data Aire
– Liebert cost about $575
20
Justification
● Belt Drive Fans
– Generates higher external static pressure to overcome duct losses
21
Spec Stopper (for Liebert)
● 4 Analog Inputs
– Standard with Liebert
– Data Aire *Cost about $250
* Example only; refer to PSG for current price
22
Reason to Omit
● 4 Analog Inputs– Seldom, if ever used
– Increases cost
– Only provide information, perform no useful function
23
Spec Stopper (for Liebert)
● Motor overload alarm
– Liebert Cost about $100
– Data Aire *Cost about $300 to $400
* Example only; refer to PSG for current price
24
Reason to Omit
● Motor overload alarm
– Redundant alarm• No air flow alarm does same thing• Internal overloads protect motor
25
Spec Stopper (for Liebert)
● Infrared Humidifier
– Standard Liebert
– Data Aire *Cost about $1,400
* Example only; refer to PSG for current price
26
Reason to Omit
● Infrared Humidifier– Efficiency
• 22% less efficient than steam generator
– Maintenance• Difficult and time consuming to clean
– Indoor Air Quality• Infrared has pan of standing water in air
stream in violation of ASHRAE
27
Spec Stopper (for Liebert)
● Field split frame into 3 pieces
– Standard Liebert DS
– Data Aire *Cost about $1,300 / split
* Example only; refer to PSG for current price
28
Reason to Omit
● Field split frame into 3 pieces
– Spec only when required
– Increases Data Aire cost needlessly
29
Spec Stopper (for Liebert)
● Self adjusting motor base
– Not available from Data Aire
● 5 year warranty on drive train
– Standard with Liebert
– Data Aire adds 8% to our price
30
How to Handle
● Specify direct drive plug fans instead of warranty and self-adjusting motor base– Cost less– More efficient – No maintenance– No belt dust– Better airflow management
31
Spec Stopper (for Liebert)
● Semi-hermetic Compressors
– Standard with Liebert
– Data Aire *Cost about $2,500
* Example only; refer to PSG for current price
32
How to Handle
● Specify Scroll Compressors In Lieu of Semi-hermetic Compressors
– Scrolls are 11.5% more efficient
– Scrolls are More reliable by 5 to 1
– Scrolls are Less expensive
Liebert Data Aire
4 Analog Inputs $ 0 $ 250
Motor Overload Alarm $ 100 $ 300
Infrared Humidifier $ 0 $1,400
Split Frame $ 0 $1,300
5 Year Drive Train Warranty $ 0 $1,600
Semi-Hermetic Compressors $ 0 $2,500
Total Increase in Cost $ 100 $7,350
Specification Control = $$$
33
34
● Increased Liebert Cost by adding Data Aire Spec Stoppers $1,960
● Reduced Data Aire Cost byDeleting Liebert Spec Stoppers $7,250
Specification Control = $$$
$ 8,860 Price Difference$ 8,860 Price DifferenceOn Data Aire Series DXOn Data Aire Series DX
$ 5,835 Price Difference$ 5,835 Price DifferenceOn Chilled Water UnitOn Chilled Water Unit
Specification Control = $$$
35
We Are Just Getting Started!We Are Just Getting Started!
There Are More Ways to Lock There Are More Ways to Lock up a Job!up a Job!
Specification Control = $$$
36
37
Spec Stopper (for Liebert)
● Digital Scroll Compressors
– Option with Liebert
– Data Aire cannot do
38
How To Handle
● Digital Scroll Compressors
– Proprietary• Liebert is only CRAC manufacturer
allowed to buy digital scroll.
– Specify hot gas bypass instead• Functionally equivalent
– Not needed in a room with multiple 2 compressor units
39
Spec Stopper
● DAFC with factory mounted pumps
– Standard Data Aire product
– Liebert only offers free-standing pumps
40
Justification
● DAFC with factory mounted pumps
– Less field labor
– Single point power connection
– Takes up less space
41
Sweet Spot
● Floor mounted DX equipment
– Especially with 2 compressors
• Promote economy of DX systems
• Suggest use of dual cooling units
• Suggest use of a DX unit as a CW backup
42
Sweet Spot
● 10 ton and 13 ton ceiling units
– Standard Data Aire product
– Liebert does not offer
43
Special
● Plug fans in floor units
– Data Aire *Cost about $1,000 to $1,500 net per fan
– Available On Data Aire DX and CW units
• Both on up flow and down flow
– Only On Liebert Chilled Water >= 30 tons
• Only on down flow
* Example only; contact Data Aire for current price
44
Justification
● Plug fans in floor units
– Up to 50% energy savings
– Less than one year payback on cost of fans
– No maintenance
– No belt dust under floor
– Excellent air flow management under floor
45
Special
● Condensing unit > 10 tons
– Data Aire *Cost about $1,200 net
– Liebert will not do
* Example only; contact Data Aire for current price
46
Justification
● Condensing unit > 10 tons
– Fewer service techs in the data room
• Improved security
• Fewer disruptions
47
Special
● R-410a
– Data Aire *Cost, add 10% to price
– Liebert will only offer R-407c
* Example only; contact Data Aire for current price
48
Justification
● R-410a
– All major manufacturers have made R-410a the standard
– R-407c charge cannot be topped off
• When a leak is repaired entire charge must be recovered and circuit charged with new refrigerant
– Refrigerant Cost
• R-407c costs 33% more than R-410a
• R-407c costs are rising and R-410a costs are falling
49
Special
● Dual power source with automatic power transfer switch
– Data Aire *Cost about $1,400 net
– Liebert does not like to do?
• Eliminates a single point of failure
* Example only; contact Data Aire for current price
Special
● Condenser fans with EC Motors
– Have not seen Liebert quote this
– Stulz will supply them
50
Justification
● Condenser fans with EC Motors
– Saves 40% of condenser fan energy
– Increased motor reliability
– Lower noise level at off peak loads
51
52
Special
● Stainless steel DARC cabinet
– Data Aire *Cost about $600 net / fan section
– Will Liebert do?
– How much?
* Example only; contact Data Aire for current price
Data Aire Is Flexible!Data Aire Is Flexible!
Following Are Examples of Following Are Examples of Specials Reps Have RequestedSpecials Reps Have Requested
Specials
53
54
● VFD mounted and wired
● High AIC disconnects
● TEFC Motors
● 2 condensate pumps with auto changeover
● Special location for electrical connections
● Special reheat kW
Electrical Specials
55
● Isolation damper control relays
● Various relays for special purposes
● Red/Blue/Yellow alarm beacon
● Mount and wire controls by others (CW only)
● Custom control sequence of operation
Controls Specials
56
● Alternate piping locations
● Copper fin coils
● Heresite coating on coils
● Stainless steel coil casing
● Special chilled water valves
● Special coil circuiting, row and fin count
● Dual chilled water or dual DX coils
Coil Specials
57
● Reverse blowers
● Aluminum panels on ceiling units
● “Lead-lined” acoustical insulation
● 16 gauge panels
● Double wall construction
Cabinet Specials
58
● Foil faced insulation
● Special length, width, and height
● Mirror image units
● Return air plenums on down flow units
● Plenums to hide duct on up flow units
Cabinet Specials
59
● Special filters
● V-bank filter sections
● Floor stands enclosed with insulated panels
● Factory painted ceiling units
● Totally special unit e.g. Exxon-Mobil unit
Cabinet Specials