7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
1/23
PREPARED
BY NA PTT PUBLIC COMPANY LIMITEDCHECKED
BY ONSHORE COMPRESSOR STATION 4PROJECT
APPROVEDBY
CERTIFIED(PTT)
NA
REV.NO.
DATE REVISEDBY
APPROVEDBY
DESCRIPTION
D1 18-Feb-08 NA ISSUED FOR ITB
D2 16-Jul-08 NA REVISION ISSUED FOR ITB
D3 18-Aug-08 NA TO CORRECT DOCUMENT
SPECIFICATION FOR
BASIS ENGINEERING DESIGN DATA (BEDD)
SPC-0804.02-99.90 REV D3
TOTAL 24 PAGES
AREA CODE OF SITE LOCATION
GENERAL AREA: 010
.
PTT PLC. CONTRACT NO. PTT PLC. PROJECT NO.
0804.02
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
2/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 2 OF 23REV: D3
CONTENTS
SECTION
1.0 GENERAL .........................................................................................3
2.0 BASIC ENGINEERING DESIGN DATA ....................................................3
2.1 PROJECT DESCRIPTION .....................................................................3
2.2 APPLICABLE CODES, STANDARDS, GOVERNMENT ACTS, AND LOCALAUTHORITY REGULATIONS ................................................................3
2.3 CLIMATIC DATA ...............................................................................4
2.4 UTILITIES .........................................................................................5
2.5 HEAT EXCHANGERS........................................................................10
2.6 MECHANICAL EQUIPMENT ...............................................................10
2.7 CIVIL ENGINEERING .........................................................................10
2.8 PIPING ...........................................................................................13
2.9 INSTRUMENTATION.........................................................................14
2.10 ELECTRICAL ...................................................................................15
2.11 PROTECTIVE COVER........................................................................17
2.12 SAFETY FACILITIES .........................................................................18
APPENDIX A UNITS OF MEASUREMENT ......................................................20
APPENDIX B FUEL GAS ANALYSIS ..............................................................23
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
3/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 3 OF 23REV: D3
1.0 GENERAL
The purpose of this standard is to provide the basis technical informationrequirements for engineering and design of the Onshore Compressor Station4.
The station will be erected adjacent to the LNG Terminal in the Map Ta PhutIndustrial estate in the Rayong province, approximately 200 km south-east
of Bangkok
2.0 BASIC ENGINEERING DESIGN DATA
2.1 Project Description
2.1.1 Client PTT PUBLIC COMPANY LIMITED
2.1.2 Station Name ONSHORE COMPRESSOR STATION 4
2.1.3 Plant Location MAP TA PHUT, RAYONG, THAILAND
2.1.4 The System of measurements shall be SI units to ISO 31 and ISO 1000 withImperial unit in bracket. For details see appendix A.
2.2 Applicable Codes, Standards, Government Acts, and Local Authority
Regulations
2.2.1 Deleted.
2.2.2 Government Acts, Regulations applying on general basis refer to SPC-0804.02-91.04 HSE Regulation.
2.2.3 Design and construction shall conform to the latest edition of the PTTspecifications, codes and/or regulations listed in ITB.
2.2.4 Code and Standard Precedence
Area of conflict between relevant specification, code and standard shall takethe following order of precedence or the most stringent one to determine theactual requirements.
a) PTT Engineering Specifications
b) Thai Standards and Statutory Regulations
c) US and International Codes and Standards
The information given in each of these standards shall be used inconjunction with all the other listed standards. Thai Standards and StatutoryRegulations shall apply if more onerous then the others.
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
4/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 4 OF 23REV: D3
2.3 Climatic Data
2.3.1 Wind
Refer to SPC-0804.02-40.05 Wind and Earthquake loadingAnd for process design: 10 m/s
2.3.2 Ambient Temperature
Maximum recorded 45.0 C
Minimum recorded 11.0 CDesign Dry Bulb 43.0 C
Minimum design temperature 10.0 CDesign wet bulb (all applications) 28.5 CMean 28.2 CDaily Mean (Max.) 32.7 CDaily Mean (Min.) 24.8 C
2.3.3 Relative Humidity
Mean Maximum 95 %Mean Minimum. 51 %Extremes Minimum 17 %
2.3.4 Rainfall
Average annual 1401 mmMaximum recorded in 24 hours 193 mmDesign rainfall 104 mm/hour for 30 minutes for
drainage system
2.3.5 Snowfall NONE
2.3.6 Barometric Pressure
Design 1021 mbarMaximum 1021 mbarMinimum 1000 mbar
2.3.7 Solar Heat
Mid-day Solar heat flux, maximum 949 W/m2
2.3.8 Atmosphere
a) Extreme moisture (tropical climate) TROPICAL CLIMATE
b) Marine exposure (salt spray) MARINE ENVIRONMENT
c) Sand storms NONE
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
5/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 5 OF 23REV: D3
2.3.9 Miscellaneous Site Data
a) Frost Level NONE
b) Thunderstorm Frequency SEASONAL (Daily May to Oct)
c) Sandstorm Frequency NONE
d) Temperature Inversion Occurrence DATA NOT AVAILABLE
2.3.10 Seismic design code
The zone of seismicity for the STATION is defined as ZONE 0 and is notsubject to seismic activity.
2.4 Utilities
2.4.1 LP Steam
Supply source: N/AUsers: N/A
Operating Conditions
Minimum Operating MaximumPressure, bar g. 2.5 4.0 4.5Temperature, C Saturated 160 170
Mechanical Design Conditions
Pressure, bar g. 9.0Temperature, C 260
2.4.2 Condensate
Condensate shall not be recovered.
2.4.3 Water
2.4.3.1 Raw water
Supply source: Third party supplierUser: Utility stations, Fire water system
Operating Conditions
Minimum Operating MaximumPressure, bar g. 4.0 6.0 7.3Temperature, C 25.0 28.0 30.0
D3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
6/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 6 OF 23REV: D3
Mechanical Design Conditions
Pressure, Bar g. 12.2Temperature, C 55.0
Quality
pH 6.0-9.0Turbidity Max. 10.0 NTUElectric Conductivity Max. 136 microsiemens/cm
Total dissolved solids Max. 132 mg/lAlkalinity Alkalinity - Phenolphthalein 0 mg/l CaCO3 Alkalinity - Total 50 mg/l CaCO3Chloride max. 18 mg/l ClCalcium max. 20 mg/l CaMagnesium max. 1.5 mg/l MgHardness max. 56 mg/l CaCO3Organic-N max. 1.3 mg/l NAmmonia-N max. 0.4 mg/l NPhosphate max. 0.23 mg/l PSulfate max. 35 mg/l SO4
Nitrate max. 1.5 mg/l NO3Dissolved SiO2 max. 19.5 mg/lDissolved oxygen max. 8.6 mg/lBOD max. 4 mg/lIron Iron - Dissolved 0 mg/l Fe Total max. 0.6 mg/l Fe
Note: Contractor shall confirm the above parameters with the supplier.
2.4.3.2 Demineralised water
Supply source: N/AUser: N/A
Operating Conditions
Minimum Operating MaximumPressure, bar g. 3.0 4.0 5.0Temperature, C 25 28 30
Mechanical Design Conditions
Pressure, bar g. 8.3
Temperature, C 55
Quality
Conductivity at 25 C max. 10 s/cm
D3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
7/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 7 OF 23REV: D3
Sodium max. 3 ppm wt. Na+Potassium max. 3 ppm wt. K+
Dissolved Iron max. 5 ppm wt. Fe+Silicon max. 5 ppm wt. SiDissolved 02 max. 0.1 mg/lSilica max. 5 ppm wt.Total Hardness max. 50 pm wt. Ca2+Suspended Solids max. 100 ppm wt. (Note)Oily matter nil
Note:- 35 ppm wt. In range of 5 to 10 micronmeters, reminder below5 micrometers
2.4.3.3 Potable water
Source: Third party supplierUser: Safety shower and Sanitary in buildings
Operating Condition
Minimum Operating MaximumPressure, bar g 1.0 3.75 4.75Temperature, C 25 28 30.0
Mechanical Design Conditions
Pressure, bar g. 5.6Temperature C 55
Note. The Contractor shall confirm the above parameters with thesupplier.
2.4.3.4 Deleted
2.4.3.5 Fire Water
Supply source : Raw water supplied by Third party supplier: Sea water (Back up) supplied by Third party supplier
Operating Conditions
Minimum Operating MaximumPressure, bar g. 7.0 11.5 14Temperature C 35
Mechanical Design Conditions
Pressure. bar g. 16.0Temperature, C 60.0
2.4.4 Air
2.4.4.1 Utility Air
Supply source: OCS4 Instrument Air Package
D3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
8/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 8 OF 23REV: D3
Users: Distribution to utility stations
Operating Conditions
Minimum Operating MaximumPressure, bar g 6.0 7.6 8.8Temperature C 50 52 52Dew Point C Uncontrolled
Oil FreeMechanical Design Conditions
Pressure bar g. 10.0Temperature C 77
2.4.4.2 Instrument Air
Supply source: OCS4 Instrument Air PackageUsers: Distribution to instrument air user
Operating Conditions
Minimum Operating Maximum
Pressure, bar g 6.0 7.6 7.6Temperature, C 50 52 52Dew Point Less than 5oC @ 8.3 barg
Less than 0oC @ atmOil free
Mechanical Design Conditions
Pressure bar g. 10.0Temperature C 77
2.4.5 Nitrogen
Supply source: OCS4 Nitrogen Package.Users: Utility stations, dry gas seals and various users
Operating Conditions
Minimum Operating MaximumPressure, bar g. Note 1 Note 1 Note 1Temperature, C 7.0 28.5 50.0Purity Less than 1000 ppm O2
Mechanical Design Conditions
Pressure, bar g. 9.0Temperature, C 75.0
D3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
9/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 9 OF 23REV: D3
Note 1. To be specified by contractor. The contractor shall ensure that
the Vendor provides the nitrogen with pressure and temperature meetthe requirement of compressor vendor.
2.4.6 Fuel
2.4.6.1 MP fuel gas
Supply source: Upstream of SDV 101 and S-101 A/B/C commonoutlet header.
Operating Conditions
Minimum Operating MaximumPressure, bar g. 30 34.5 42Temperature C -10 Between min
and max30
Mechanical Design Conditions
Pressure, bar g. 51Temperature C 55
2.4.6.2 LP fuel gas
Supply source: Let down from MP fuel gasUser: Flare purge/pilot.
Operating Conditions
Minimum Operating MaximumPressure, bar g. 0.5-1Temperature, C 22
Mechanical Design Conditions
Pressure, bar g. 7Temperature, C 150
2.4.6.3 Fuel gas characteristics analysis is shown on appendix B.
2.4.8 Pressure Vessels and Tankage
Welded Unfired Pressure Vessels
a) Engineering Specification SPC-0804.02-20.01 Vessel Standardshall be applied for Pressure Vessel Design.
b) Engineering Specification SPC-0804.02-20.02 Quality requirementfor Pressure Vessel shall be applied for Pressure VesselFabrication.
D3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
10/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 10 OF 23REV: D3
2.4.9 Tankage
2.4.9.1 Engineering Specification SPC-0804.02-20.06 Field erected low pressurestorage tank shall be applied for low pressure storage tanks Fabrication.
2.4.9.2 Not used
2.5 Heat Exchangers
Air Coolers
2.5.1 Air cooled exchangers shall be designed in accordance with EngineeringStandard SPC-0804.02-20.22 Air Cooled heat Exchanger.
2.5.2.2 The design air inlet temperature shall be 40 oC dry bulb unless specifiedotherwise on the Process Datasheet.
2.5.2.3 The minimum ambient temperature shall be 15 oC dry bulb.
2.5.2.4 Fans shall be forced draft type unless specified otherwise on the ProcessDatasheet.
2.5.2.5 The preferred tube lengths for Air Coolers shall be 9144 mm or 12195mm.
2.5.2.6 The preferred tube sizes for air coolers shall be as API661 or other.
2.5.2.7 Winterising is not required.
2.5.2.8 Accelerometer and velometer type vibration transmitters shall beprovided for motors and fans respectively.
2.5.2.9 Minimum requirement of structure column size and quantity shall beH200, 6 columns per bay.
2.6 Mechanical Equipment
2.6.1 Pumps, Compressors and Turbines
2.6.1.1 Pumps, compressors and turbines shall be specified in accordance withthe related specifications, applicable National and Local Codes listed inthe contract document
2.6.1.2 Deleted
2.6.1.3 Air blower design shall use 77 % relative humidity, 40 oC dry bulbtemperature.
2.6.1.4 Deleted
2.7 Civil Engineering
D3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
11/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 11 OF 23REV: D3
2.7.1 Site Preparation
Site shall be prepared and levelled by CONTRACTOR. Site Preparationshall be in accordance with site preparation drawings prepared by thecontractor.
2.7.2 Soil Conditions
2.7.2.1 A preliminary soils report is attached in the ITB.
2.7.2.2 A soil profile is available by reference to bored hole logs in soil report.
2.7.2.3 Foundation design:
Foundations shall be in accordance with Engineering Specification SPC-0804.02-40.11 Foundation and Structural support for Machinery.
2.7.2.4 For piles:
Type & size, capacity, maximum uplift and lateral resistance shall bereferred to Preliminary Soil Report for the design and construction.
2.7.2.5 Type of foundations:
a) Major equipment, buildings and structures: Concrete foundation
b) Minor equipment, pipe supports : Concrete foundation
2.7.3 Paving/Water Run-Off/Sewers
2.7.3.1 a) Paving shall be provided in process area (concrete paving), controlbuilding and substation area (concrete paving), Maintenance area(concrete paving), Product storage (concrete paving) ,slopeprotection (concrete paving) and/or as identified on overall plotplan.
b) Access ways shall be concrete paved.
c) Run-off design factors are in accordance with EngineeringSpecification SCP-0804.02-40.13 Drainage Design.
d) Roadways shall be paved in according with the EngineeringSpecification SPC-0804.02-40.12 Specification for Road andPaving.
2.7.3.2 Surface drainage systems shall be designed in accordance withEngineering Specification SPC-0804.02-40.13 Drainage Design.
2.7.3.3 The following drainage systems shall be provided:
Storm DrainageOily Water DrainageSanitary SewerD3
D3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
12/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 12 OF 23REV: D3
Closed Drain System
2.7.3.4 Additional sloping of grade shall be provided in fire risk areas.
2.7.3.5 Sewer pipe shall be designed in accordance with EngineeringSpecification SPC-0804.02-40.13 Drainage Design.
2.7.4 Waste Treatment Facilities
2.7.4.1 Waste treatment facilities are to be provided as follows:
Type Waste Exiting Partially To be providedby PTT by CONTRACTOR
Oily [ ] []
Sanitary [ ] []
Chemical [ ] []
Other [ ] []
2.7.4.1 Waste water from Raw water filtering system shall be treated to meet
PROJECT SPECIFICATION by its unit.
2.7.5 Unit Elevation
2.7.5.1 Site preparation elevation to be confirmed by CONTRACTOR.
2.7.5.2 High Point of Paving (HPP) for different areas is to be determined by theCONTRACTOR based on survey data and requirements for access anddrainage of site. HPP shall be referenced to the PTT station Datum andagreed with PTT.
Station design elevation shall be considered as high point of paving andequal to be 0.000 m.
2.7.5.3 Minimum height for top of foundations above high point of paving shallbe per Engineering Specification SPC-0804.02-40.12 Specification forRoad and Paving.
2.7.6 Structural Materials
2.7.6.1 a) Structural material shall be in accordance with Engineering
Specification SPC-0804.02-40.07 Structural steelwork design.
b) Deleted
2.7.6.2 In general, elevated walkways and platforms shall be Hot Dip GalvanizedD3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
13/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 13 OF 23REV: D3
Grating. Checkered plate shall be used where only specified by PTT.
2.7.6.3 Pipe supports shall be in accordance with Engineering Specification SPC-0804.02-50.01 Piping Arrangement.
2.7.7 Buildings
2.7.7.1 Buildings shall be in accordance with related project documentation.
2.7.7.2 Air conditioning shall be provided for the control, substation, warehousebuildings and guardhouse.
2.7.7.3 Pressurising is required for the substation, control building andcompressor shelter.
2.7.8 Security
2.7.8.1 PVC coated perimeter fencing type chain link diamond mesh shall beprovided.
2.7.8.2 Area fencing is required as shown on overall plot plan 01-3-0804.02-6000-002.
2.7.8.3 Security gate house shall be provided at the entrance to the facility. Maingate with traffic shall be polished stainless steel sliding gate.
2.7.8.4 All building shall be equipped with computerized ID card touched accesscontrol.
2.7.9 Roads specification shall be referred to SPC-0804.02-40.12.
2.8 Piping
2.8.1 Piping shall be designed in accordance with the edition plus Addenda ofthe ASME/ANSI Code for Pressure Piping: Chemical Plant and PetroleumRefinery Piping, ASME/ANSI B31.3; Gas Transmission and DistributionPiping, ASME/ANSI B31.8 and other sections which apply as listedbelow in remarks:
2.8.1.1 Piping shall be designed in accordance with Engineering SpecificationsSPC-0804.02-50.01 Design Fabrication, Inspection and Testing of
Piping, SPC-0804.02-50.03 Piping Lay Out and SPC-0804.02-50.05Piping Arrangement and other applicable specifications
2.8.1.2 Not used.
2.8.1.3 Severe Cyclic Service Lines
ASME/ANSI B31.3 requires the designer to identify those lines subject to
D3
D3
D3
D3
D3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
14/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 14 OF 23REV: D3
severe cyclic conditions. These conditions exist where SE exceeds 0.8SA and the equivalent number of cycles exceeds 7000; or where other
conditions will produce an equivalent effect.
These lines shall be identified on line classification list by CONTRACTOR.
2.9 Instrumentation
2.9.1 Instrumentation and Control Systems shall be furnished in accordancewith Piping and Instrument Diagrams, and other instrument engineeringspecifications, project philosophy and the scope of work Volume 1 Part5.
2.9.2 Deleted
2.9.3 Deleted
2.9.4 Deleted
2.9.5 Deleted
2.9.6 Deleted
2.9.7 Analysers
Analysers are required as shown on Engineering Flow Diagram.
Analyser Location:[ ] Local Enclosures[ ] Central Analyser House
[] Area/Unit Analyser House
2.9.8 Package Equipment Instrumentation
Instrumentation Supplied by:
[]CONTRACTOR[] Manufacturer Manufacturer-Supplied Instrumentation[] Supplied to Engineering Standard SPC-0804.02-60.01 InstrumentGeneral Specification and other related specifications drawings andcontract documents.[ ] Other
2.9.9 Control Valves
Primary type of Modulating Control Valve shall be:
[] Globe-Type (see Note 1)[ ] Wafer/Butterfly Type
[ ] Rotary Plug Type [ ] Other
The type chosen shall be the type used for routine applications.
Other types shall be used as required by process.
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
15/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 15 OF 23REV: D3
Valve positioners shall be:
[ ] Pneumatic[] Electropneumatic[ ] Pneumatic + I/P Converter
2.9.10 Special Approval Agency Requirements
Approval of instruments and/or systems is required by:
[] BASEEFA [ ] PTB[ ] CSA [ ] Other
2.9.11 Transmitted Signal Levels:[] Electronic 4-20 mA, [] Foundation Fieldbus
Pneumatic:
[ ] 3-15 Psig [] 0.2 - 1.0 Barga
2.9.12 Electrical Equipment in Hazardous Areas
Electronic instrumentation in hazardous areas shall be based upon:
[] intrinsically safe[ ] explosion proof/flame proof
[ ] non-indecisive/non-sparking[ ] Other
See section 2.9.10 above for approval authority
2.9.13 Instrument Installation
Cable routing
Service Underground Above Direct Conduit TrayGround Buried
ISBL [ ] [] [ ] [ ] []
OSBL [ ] [] [ ] [ ] []
Cable Types
ISBL: - Armoured
OSBL: - Armoured
Process Hook-ups [] Tubing [ ] Piping
2.10 Electrical
2.10.1 General requirements for electrical equipment, materials and design shall
D3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
16/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 16 OF 23REV: D3
be in accordance with Engineering Specifications for Electrical andTelecommunication System.
2.10.2 Power Supply
The system characteristics shall be as follows:
2.10.2.1 Incoming supply refer to SPC-0804.02-70.01 and Single Line Diagram70-3-0804.02-6000-001
2.10.2.2 Deleted.
2.10.2.3 The power source location at the battery limit shall be referred to SPC-0804.02-70.01 and Single Line Diagram 70-3-0804.02-6000-001.
2.10.2.4 The maximum 3 phase fault level shall be referred to SPC-0804.02-70.01.
2.10.2.5 An emergency power supply shall be provided by CONTRACTOR inaccordance with Engineering Specification SPC-0804.02-70.02.08 Dieselgenerator Set
2.10.2.6 An Uninterruptible Power Supply shall be provided by CONTRACTOR inaccordance with Engineering Standard SPC-0804.02-70.02.06Uninterruptible Power Supply.
2.10.2.7 Generally, the ISBL systems Voltage Levels and System Design Datashall be designed, performed, operated and utilized as specified in SPC-0804.02-70.01 section 2.0 System design.
2.10.3 Utilisation Voltages shall be designed, performed, operated and utilizedas specified in SPC-0804.02-70.01 section 2.0 system design.
2.10.4 Distribution and Lighting
2.10.4.1 Service
AboveGround
DirectBuried
Conduit Tray
Power ISBL ISBL ISBLOSBL OSBL OSBL
Lighting ISBL ISBL ISBLOSBL OSBL OSBL
Communication ISBL ISBLOSBL OSBL
2.10.4.2 Cable Types shall refer to SPC-0804.02-70.01 section 2.14 Cable andWiring.
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
17/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 17 OF 23REV: D3
2.10.4.3 Area Classification and minimum required type of Protection for
equipment in Hazardous Areas shall be designated as SPC-0804.02-70.01 section 1.3 Hazardous Area.
2.10.4.4 Detail Single Line Diagrams shall be provided by CONTRACTOR.
2.10.4.5 The location of motor control stations shall be in the substation building.
2.10.4.6 Lighting fixtures shall refer to SPC-0804.02-70.01 section 2.16Lighting.
2.10.4.7 Soil Characteristics such as Soil Temperature, Soil Thermal Resistivityand Soil Resistivity shall refer to Preliminary Soil Report.
2.10.4.8 Supplementary Lighting shall be provided.
Type Location
Emergency Critical Plant, wherever safety requirement
Aviation obstruction According to ICAO
Security Exit/entry and control room
Other Indication Purpose for Safety
2.10.4.9 Offsite lighting shall be provided.
2.10.5 Miscellaneous Requirements
2.10.5.1 A fire alarm system shall be provided.(Also see Section 13 Safety Facilities)
2.10.5.2 Not used
2.10.5.3 A communications system shall be provided in accordance with SPC-0804.02-70.01 section 2.13 Communication system.
2.11 Protective Cover
2.11.1 Insulation for hot piping and equipment
Insulation for hot piping and equipment shall be in accordance with SPC-0804.02-93.01 Hot Insulation.
2.11.2 Insulation for cold piping and equipment
Insulation for cold piping and equipment shall be in accordance with SPC-0804.02-93.02 Cold Insulation.
2.11.3 Winterising is not applicable on this plant.
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
18/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 18 OF 23REV: D3
2.11.4 External heating
2.11.4.1 External heating for piping and equipment shall be electric tracing asspecified on Piping and Instrument diagram.
2.11.5 Personnel Protection
2.11.5.1 Piping and equipment operating at or above 60 oC shall be provided withinsulation guards for personnel protection where accessible.
2.11.6 Fireproofing
2.11.6.1 Fireproofing of equipment and supports shall be provided in accordancewith Engineering Standard SPC-0804.02-93.05 External Fireproofing forequipment support and structure and Attachment provided in ITB.
2.11.7 Painting
2.11.7.1 Painting for all piping, equipment structures and all externals shall be inaccordance with Engineering Standard SPC-0804.02-93.06 Painting.(included internal painting prior to internal lining of WHRU ,Boiler ,Stack.Linings of internals are excluded)
2.11.8 Wrapping Underground Pipe
2.11.8.1 Coating and wrapping of underground steel pipe shall be in accordancewith Engineering Standard SPC-0804.02-92.07 Cathodic protection ofOnshore and buried pipe.
2.11.9 Galvanising
Galvanising of iron and steel items shall be accordance with SPC-0804.02-40.08 Structural Steel Fabrication and Erection.
2.12 Safety Facilities
2.12.1 Fire Fighting
Fire Fighting facilities shall be provided in accordance with specificationSPC-0804.02-90.03 Fire and Gas Specification and 19-1-0804.02-6000-01 Conceptual Fire Protection plan.
2.12.1.1 Deleted
2.12.1.2 Deleted
2.12.1.3 A foam system shall be provided in accordance with EngineeringStandard SPC-0804.02-90.03 Fire and Gas Specification.
2.12.1.4 Sprinkler systems shall be Water Spray systems are covered in the Fireand Gas Detection and Protection Specification SPC-0804.02-90.03.
D3
D3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
19/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 19 OF 23REV: D3
2.12.1.5 Detection, Alarm and Control Systems shall be provided in accordance
with Engineering Standard SPC-0804.02-90.03 Fire and GasSpecification.
Fire and Safety Display System in process area shall be centralised in thecontrol room.
2.12.2 Blowdown and Flare System
2.12.2.1 Blowdown and flare facilities shall be provided.
2.12.2.2 Flare shall be elevated type.
2.12.2.3 Not used.
2.12.2.4 Relief valves handling hydrocarbon vapour shall be vented to a closedrelief system.
2.12.2.5 The liquid relief system shall be combined with the vapour relief system.
2.12.2.6 The allowable ground level radiation shall be 6.3 KW/m2.
2.12.2.7 The air pollution control requirements shall be in accordance with PTTrelated specifications.
2.12.3 Aircraft Warning Lights
2.12.3.1 Warning lights for aircraft shall be provided on the following tallstructures.
Note: See also SPC-0804.02-70.01 Electrical and Communicationstandard Section 2.16.4 Aircraft warning lights.
2.12.4 Safety Showers
Safety showers and eye wash stations (fountain type) shall be providedby CONTRACTOR in accordance with SPC-0804.02-90.04 PersonnelProtection and SPC-0804.02-50.05 Piping Layout.
D3
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
20/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 20 OF 23REV: D3
APPENDIX A UNITS OF MEASUREMENT
UNITS OF MEASUREMENT
The units of measurement to be used on this project are the International System ofunits (SI) with the imperial unit in bracket, except for the rating and sizing of pipingand equipment nozzles where pound-inch units shall be used.
Description Name Symbol Remarks
Length kilometer kmMeter mMillimeter mm
Mass (weight) metric ton t, ton *Kilogram kgGram gMicro gram micro equivalent
to10-6gMolecular weight kilo mole kmol *
Mole mol *
Area square meter m2square centimeter cm2
square millimeter mm2
Concentration Mole percent mol %Mole fraction -Weight percent % by weightWeight fraction -
Volume (for gas Parts per million ppmand solid) Cubic meter m3
Cubic centimeter cm3Cubic millimeter mm3
(for liquid) Cubic meter m3litre l *
Temperature Degree centigrade C *Kelvin K (K=C + 273.15 (K
is used for physicalvariables)
Plan angle Degree *
Time Year y *Day d *
Hour h *Minute min *Second s
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
21/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 21 OF 23REV: D3
Description Name Symbol Remarks
Force Newton NStress Megapascal MPa
(1 pa=1N/m2) *
Hardness - N/mm2
Pressure
- gauge Bar gauge Barg *
- absolute Bar absolute Bara *(1 bar =
1.020 kg/cm2)
Velocity Meter/second m/sKilometer/hour km/h
Flow
- volume Cubic meter/hour m3/h- weight Ton/hour or
kilogram/hour t/h or kg/h *
- gases Normalcubicmeter/hour at 0C, Nm3/h *1.013 bara kilogram Kmol/hmole/hour mole/hour Mol/sor millions mole standard cubic feet per day MMSCFD
Density Kilogram/cubic meter kg/m3
Linear expansion - m/(m x K) *Coefficient (or m/mC)
Impact strength Joule/square meter or J/m2 or J/cm2Joule/square centimeter
Energy, enthalpy, heatJoule or kilojoule J or kJ
Specific enthalpy kJ/kg, J/mol
Heating value kJ/kg or J/mol
Heat duty, electric Watt kW (or kJ/s) 1 W = 1 J/sPower = 0.860 kcal/h
Heat flux J/(m2 x s) (or W/m2)(or J/m2 x h))
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
22/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 22 OF 23REV: D3
Description Name Symbol Remarks
Specific conductivity kJ/(kg x K)J/(mol x K)
Thermal conductivity W/mK 1W/K = 0.860Kcal/mhC
Heat transfer coefficient W/m2K
Absolute viscosity cP
Kinematic viscosity m2/s (or mm2/s)
Fouling factor m2K/W (1 m2K/W = 1.163m2hC/kcal)
Surface tension N/m (1N/m=1,000 dyn/cm)
Sound pressure level decibel dB
Rotating speed revolutions per second s-1 (or 1/s) min-1or minute (or 1/min)
Electric current ampere AMilliampere mA
Voltage volt V
Frequency hertz Hz, 1/s
Electric resistance ohm
Electric energy Kilowatt hour KWh
Intensity of illumination Lx (Lx = 1m/m2)
Moment N x m
Notes
1. Symbols marked * are deviating from the SI system.
2. Further units outside the SI can be agreed upon after consultation with PTT.
3. Pipe diameters shall be in inches (primarily) or mm (limited for special
application).
7/30/2019 SPC-0804.02-99.90 Rev D3 BEDD
23/23
BASIS ENGINEERING
DESIGN DATA (BEDD)
PTT PUBLIC COMPANY LIMITED
ENGINEERING SPECIFICATION
SPC-0804.02-99.90
PAGE: 23 OF 23REV: D3
APPENDIX B FUEL GAS ANALYSIS
See table 5.1 of the Part 5 Volume 1 scope of work