7/30/2019 Sp Ceil 011 Inst Sheet
http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 1/7
ISSUED: 1-5-04 SHEET #: 055-9196-1
Visit the InFocus Web Site at www.infocus.com
1 of 7
Read instruction sheet before you start installation and assembly.
Maximum Load Capacity: 50 lb (27 kg)
Installer must verify that the ceiling will safely supportthe combined weight of projector mount and projector.WARNING
IMPORTANT! Be sure not to touch the projector while tightening the set screw on theball and socket mount. This may cause the image to be unaligned when you let go.
Installation and Assembly - All-in-one Projector Adapter Plate for
InFocus ® ProjectorsModels: SP-CEIL-011
R
Installations:
Flush Mount ......................................................................................................................................... step 1, page 3
Wood Joist Finished Ceilings,
Exposed Wood Joists, or Wood Beam Ceilings .............................................................................. step 2, page 3
Concrete Ceilings ............................................................................................................................................ page 4
Extension Columns ......................................................................................................................................... page 5
IMPORTANT! Turn to the appropriate page for your ceiling installation.
SET SCREW
This product is intended for use with ULListed products and must be installedby a qualified professional installer.
7/30/2019 Sp Ceil 011 Inst Sheet
http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 2/7
ISSUED: 1-5-04 SHEET #: 055-9196-1
Visit the InFocus Web Site at www.infocus.com
2 of 7
B
Parts List
C
Before you start check the parts list to insure all of the parts shown are included.
E
A
D
G
FH
Description Qty. Part Number
A ball and socket mount 1 055-0011
B 4 mm security allen wrench 1 560-9646
C M5 x .8 x 10 mm socket pin type F screw 1 520-1164
D #10-32 x 3/8 spade thumb screw 1 560-1107E #10-32 x 3/8 serrated washer head socket pin screw 1 520-1151
F #14 x 2.5 phillips hex head wood screw 2 5S1-015-C03
G ceiling plate 1 580-1042
H .25" ID x .56" OD x .26 spacer 2 590-1050
I extension column connector 1 580-1013
J 10-32 x 3/8 socket pin screw 2 520-1084
K 10-32 x 3/16 slotted set screw 1 520-1187
L adapter plate 1 055-1445
M M4 x 16 mm serrated washer head socket pin screw 3 510-1087
N M4 x 12 mm serrated washer head socket pin screw 1 510-1079
O .198 x .313 x .375 retaining spacer 3 590-2020
P .198 x .313 x .187 retaining spacer 1 590-1030
I
Note: Actual parts may appear slightly different than illustrated.
J
.ASTENERS
KL
M N
O
P
7/30/2019 Sp Ceil 011 Inst Sheet
http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 3/7
ISSUED: 1-5-04 SHEET #: 055-9196-1
Visit the InFocus Web Site at www.infocus.com
3 of 7
FF
G
WOODJOIST
CEILINGDrill two 5/32" (4 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Attach ceiling plate (G)with two #14 x 2.5" (6 mm x 65 mm) wood
screws (F) as shown using 3/8" (10 mm) socketwrench. Tighten wood screws (F) so ceiling
plate (G) is firmly attached.
DO NOT TIGHTEN WITH EXCESSIVE FORCE!Over-tightening can cause stress damage to
wood screws (F) greatly reducing their holdingpower! Tighten to 80 in • lb (9 N.M.) maximum
torque.
Skip to step 5.
WARNING: It is the responsibility of the
installer to verify that the ceiling will safelysupport the combined load of all attached
hardware and components.IMPORTANT: Be sure to drill holes into thejoist CENTER!
For Optional Cord Management,install two spacers (H) between ceiling
plate (G) and ceiling.
Screw ball and socket mount (A) into ceiling plate (G). Align the notch with one of the four holes of the ceiling plate(G) and secure ball and socket mount (A) with a M5 x 10 mm socket pin screw (C) using security allenwrench (B) as shown in detail 1.Note: Slotted set screw (K) is used to jam against the threads of the ball andsocket mount to prevent any excess movement of the ball and socketmount (A). Do not over-tighten screw; over-tightening screw will damagethreads making it difficult to separate the products.
Skip to step 5.
DETAIL 1
A
G
A
CWOODJOIST
CEILING
NOTCH
G
.lush Mount Installation
K
Installation To Wood Joist .inished
Ceilings, Exposed Wood Joists,
or Wood Beam Ceilings
H
7/30/2019 Sp Ceil 011 Inst Sheet
http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 4/7
ISSUED: 1-5-04 SHEET #: 055-9196-1
Visit the InFocus Web Site at www.infocus.com
4 of 7
CAUTION: Tighten wood screws so ceiling plate(G) is firmly attached. DO NOT TIGHTEN WITH
EXCESSIVE FORCE! Over-tightening can causestress damage to wood screws, greatly reducing
their holding power! Tighten to 80 in • lb (9 N.M.)
maximum torque.
Drill two 1/4" (6 mm) dia. holes to a minimum depth of2.5" (64 mm). Attach ceiling plate (G) using two
concrete anchors and #14 x 2.5" wood screws (F) asshown in Illustration A and 1, 2, and 3 (below).
Tighten all fasteners.
Skip to step 5.
IMPORTANT: It is the responsibility of the installerto verify that the ceiling will safely support the
combined load of all attached hardware andcomponents.
1
3
Drill hole and insert anchor
Place ceiling plate over anchor and secure with screw
After repeating step one tighten all fasteners C U T A W
A Y V I E W
INCORRECT
concretemetalbracket
plaster/ dry wall
CORRECT
concretemetalbracket
plaster/ dry wall
FOR DIRECT ATTACHMENT TO LOAD BEARING CONCRETE
ONLY! Concrete expansion anchors are not intended forattachment to concrete ceilings covered with a layer of plaster,drywall, or other finishing material. If mounting to concrete
ceiling covered with plaster / drywall is unavoidable, plaster / drywall must be counterbored as shown below.
concreteceiling
concreteanchor
concreteanchor
concrete
anchor
F
F
F
Illustration A
Installation to Concrete CeilingsAlligator ® concrete anchors are recommended
concreteanchor
G
2
G
CONCRETE CEILING
7/30/2019 Sp Ceil 011 Inst Sheet
http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 5/7
ISSUED: 1-5-04 SHEET #: 055-9196-1
Visit the InFocus Web Site at www.infocus.com
5 of 7
Screw extension column to ceiling plate (G).Align the notch with one of the four holes in
the ceiling plate (G) and secure extensioncolumn with a M5 x 10 mm socket pinscrew (C) using security allen wrench (B).
See detail 3.
Screw extension column connector (I) to
extension column. Align slot in extensioncolumn with one of the top holes in
extension column connector (I). Insert andtighten one 10-32 x 3/8 socket pin screw (J)through extension column connector (I) into
slot on extension column using securityallen wrench (B). See detail 4.
Screw ball and socket mount (A) toextension column connector (I). Align slot in
ball and socket mount (A) to one of the
bottom holes in extension column connector(I). Insert and tighten one 10-32 x 3/8 socketpin screw (J) through extension columnconnector into slot in ball and socket mount
(A) using security allen wrench (B).
Note: Slotted set screw (K) is used to jamagainst the threads of the ball and socketmount to prevent any excess movement ofthe ball and socket mount (A). Do not over-tighten screw; over- tightening screw willdamage threads making it difficult toseparate the products.
DETAIL 6
A
EXTENSIONCOLUMN
SLOT
I
J
SLOT
SLOT
EXTENSIONCOLUMN (SOLD
SEPARATELY)
G
I
DETAIL 4
EXTENSIONCOLUMN
SLOT
I
J
DETAIL 3
EXTENSIONCOLUMN
CG
Installation toExtension Column
A
K
7/30/2019 Sp Ceil 011 Inst Sheet
http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 6/7
ISSUED: 1-5-04 SHEET #: 055-9196-1
Visit the InFocus Web Site at www.infocus.com
6 of 7
Flip projector upside down. Find your projector from the models listed below. Using the holes indicated on thecorresponding hole pattern diagram, attach adapter plate (L) to projector using three M4 x 16 mm serrated washer
head socket pin screws (M) and three .198 x .313 x .375 retaining spacers (O).Notes:
Retaining spacers go between adapter plate and projector.* Notch indicates front of projector.** Projectors using hole pattern G use one M4 x 12 mm screw (N) and one .198 x .313 x .187 retaining spacer (P)
where indicated.
A. C200, C420, DP6500X, DP8200X,LP650, LP820, SP7200, SP7205
* * *
***
*
**
B. C40, C50, DP2000S/X, LP240,LP250
D. C100, C105, DP6150, DP6155,
LP690
E. C110, DP8000, LP790,
SP4800, SP4805, X1, X2
F. C170, LP600
C. LP340, LP350, LP500, LP530,SP110
G. C160, C180, LP540, LP640
7/30/2019 Sp Ceil 011 Inst Sheet
http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 7/7
ISSUED: 1-5-04 SHEET #: 055-9196-1
Visit the InFocus Web Site at www.infocus.com
7 of 7
WARNING: Do not lift more weight than you can handle!
Use additional man power or mechanical lifting
equipment to safely handle placement of the projector!
To adjust roll, pitch, and yaw loosen the set screw
(shown below) using security allen wrench (B) or
standard 4 mm allen wrench. You should be able to
just slightly loosen the screw so that your adjustments
can be set without having to hold the projector. Moveprojector to desired position and slowly tighten set
screw.
Note: Be sure not to touch the projector while
tightening the set screw. This may cause the image
to be unaligned when you let go.
IMPORTANT: Allen wrench is your key for projector
removal. Store it in a safe place.
Note: The projector you are installing may differ in appearance from the sample illustrated below.
© 2004 Peerless Industries, Inc. All rights reserved.
Peerless is a registered trademark and Armor Lock is a trademark of Peerless Industries Inc.All other brand and product names are trademarks or registered trademarks of their respective owners.
SET SCREW
Attach projector to the ball and socket mount (A) by
inserting the ball and socket mount (A) into the
adapter plate connection and twisting until the adapter
plate will no longer turn (about 75°). The spring loaded
captive screw should line up with a correspondinghole on the adapter plate (this should line up auto-
matically when the two are connected). Push down
and tighten the spring loaded captive screw to secure
the adapter plate to the mount. If not using the optional
security feature, fasten thumb screw (D) in the hole
opposite the spring loaded captive screw.
OPTIONAL: For Armor Lock™ security, insert serrated
washer head socket pin security screw (E) in the hole
opposite the spring loaded captive screw. Tighten with
security allen wrench (B). This will prevent the
projector from being removed.
Note: Be sure to only use the 10-32 x 3/8" screw (E)(or the thumb screw (D)) opposite the spring loaded
captive screw.
A
WOODJOIST
CEILING
PROJECTOR ADAPTER PLATE
PROJECTOR
WOODJOIST
CEILING
PROJECTOR
E
2
1
D
CAPTIVE
SCREW