8
ISSUED: 1-5-04 SHEET #: 055-9196-1 Visit the InFocus Web Site at www.infocus.com 1 of 7 Read instruction sheet before you start i nstallation and assembly. Maximum Load Capacity: 50 lb (27 kg) Installer must verify that the ceiling will safely support the combined weight of projector mount and projector. WARNING IMPORTANT! Be sure not to touch the projector while tightening the set screw on the ball and socket mount. This may cause the image to be unaligned when you let go. Installation and Assembly - All-in-one Projector Adapter Plate for InFocus  ® Projectors Models: SP-CEIL-011 R Installations: Flush Mount ......................................................................................................................................... step 1, page 3 Wood Joist Finished Ceilings, Exposed Wood Jois ts, or Wood Beam Ceilings .............................................................................. step 2, page 3 Concre te Ceilings ............................................................................................................................................ page 4 Exten sionColumns ......................................................................................................................................... page 5 IMPORTANT! T urn to the appropriate page for your ceiling installation. SET SCREW This product is intended for use with UL Listed products and must be installed by a qualified professional installer.

Sp Ceil 011 Inst Sheet

Embed Size (px)

Citation preview

Page 1: Sp Ceil 011 Inst Sheet

7/30/2019 Sp Ceil 011 Inst Sheet

http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 1/7

ISSUED: 1-5-04 SHEET #: 055-9196-1

Visit the InFocus Web Site at www.infocus.com

1 of 7

Read instruction sheet before you start installation and assembly.

Maximum Load Capacity: 50 lb (27 kg)

Installer must verify that the ceiling will safely supportthe combined weight of projector mount and projector.WARNING

IMPORTANT! Be sure not to touch the projector while tightening the set screw on theball and socket mount. This may cause the image to be unaligned when you let go.

Installation and Assembly - All-in-one Projector Adapter Plate for

InFocus ®  ProjectorsModels: SP-CEIL-011

R

Installations:

Flush Mount ......................................................................................................................................... step 1, page 3

Wood Joist Finished Ceilings,

Exposed Wood Joists, or Wood Beam Ceilings .............................................................................. step 2, page 3

Concrete Ceilings ............................................................................................................................................ page 4

Extension Columns ......................................................................................................................................... page 5

IMPORTANT! Turn to the appropriate page for your ceiling installation.

SET SCREW

This product is intended for use with ULListed products and must be installedby a qualified professional installer.

Page 2: Sp Ceil 011 Inst Sheet

7/30/2019 Sp Ceil 011 Inst Sheet

http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 2/7

ISSUED: 1-5-04 SHEET #: 055-9196-1

Visit the InFocus Web Site at www.infocus.com

2 of 7

B

Parts List

C

Before you start check the parts list to insure all of the parts shown are included.

E

A

D

G

FH

Description Qty. Part Number

A ball and socket mount 1 055-0011

B 4 mm security allen wrench 1 560-9646

C M5 x .8 x 10 mm socket pin type F screw 1 520-1164

D #10-32 x 3/8 spade thumb screw 1 560-1107E #10-32 x 3/8 serrated washer head socket pin screw 1 520-1151

F #14 x 2.5 phillips hex head wood screw 2 5S1-015-C03

G ceiling plate 1 580-1042

H .25" ID x .56" OD x .26 spacer 2 590-1050

I extension column connector 1 580-1013

J 10-32 x 3/8 socket pin screw 2 520-1084

K 10-32 x 3/16 slotted set screw 1 520-1187

L adapter plate 1 055-1445

M M4 x 16 mm serrated washer head socket pin screw 3 510-1087

N M4 x 12 mm serrated washer head socket pin screw 1 510-1079

O .198 x .313 x .375 retaining spacer 3 590-2020

P .198 x .313 x .187 retaining spacer 1 590-1030

I

Note: Actual parts may appear slightly different than illustrated.

J

.ASTENERS

KL

M N

O

P

Page 3: Sp Ceil 011 Inst Sheet

7/30/2019 Sp Ceil 011 Inst Sheet

http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 3/7

ISSUED: 1-5-04 SHEET #: 055-9196-1

Visit the InFocus Web Site at www.infocus.com

3 of 7

FF

G

WOODJOIST

CEILINGDrill two 5/32" (4 mm) dia. holes to a minimum

depth of 2.5" (64 mm). Attach ceiling plate (G)with two #14 x 2.5" (6 mm x 65 mm) wood

screws (F) as shown using 3/8" (10 mm) socketwrench. Tighten wood screws (F) so ceiling

plate (G) is firmly attached.

DO NOT TIGHTEN WITH EXCESSIVE FORCE!Over-tightening can cause stress damage to

wood screws (F) greatly reducing their holdingpower! Tighten to 80 in • lb (9 N.M.) maximum

torque.

Skip to step 5.

WARNING: It is the responsibility of the

installer to verify that the ceiling will safelysupport the combined load of all attached

hardware and components.IMPORTANT: Be sure to drill holes into thejoist CENTER!

For Optional Cord Management,install two spacers (H) between ceiling

plate (G) and ceiling.

Screw ball and socket mount (A) into ceiling plate (G). Align the notch with one of the four holes of the ceiling plate(G) and secure ball and socket mount (A) with a M5 x 10 mm socket pin screw (C) using security allenwrench (B) as shown in detail 1.Note: Slotted set screw (K) is used to jam against the threads of the ball andsocket mount to prevent any excess movement of the ball and socketmount (A). Do not over-tighten screw; over-tightening screw will damagethreads making it difficult to separate the products.

Skip to step 5.

DETAIL 1

A

G

A

CWOODJOIST

CEILING

NOTCH

G

.lush Mount Installation

K

Installation To Wood Joist .inished

Ceilings, Exposed Wood Joists,

or Wood Beam Ceilings

H

Page 4: Sp Ceil 011 Inst Sheet

7/30/2019 Sp Ceil 011 Inst Sheet

http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 4/7

ISSUED: 1-5-04 SHEET #: 055-9196-1

Visit the InFocus Web Site at www.infocus.com

4 of 7

CAUTION: Tighten wood screws so ceiling plate(G) is firmly attached. DO NOT TIGHTEN WITH

EXCESSIVE FORCE! Over-tightening can causestress damage to wood screws, greatly reducing

their holding power!  Tighten to 80 in • lb (9 N.M.)

maximum torque.

Drill two 1/4" (6 mm) dia. holes to a minimum depth of2.5" (64 mm). Attach ceiling plate (G) using two

concrete anchors and #14 x 2.5" wood screws (F) asshown in Illustration A and 1, 2, and 3 (below).

Tighten all fasteners.

Skip to step 5.

IMPORTANT: It is the responsibility of the installerto verify that the ceiling will safely support the

combined load of all attached hardware andcomponents.

1

3

Drill hole and insert anchor

Place ceiling plate over anchor and secure with screw

After repeating step one tighten all fasteners   C   U   T   A   W

   A   Y   V   I   E   W

INCORRECT

concretemetalbracket

plaster/ dry wall

CORRECT

concretemetalbracket

plaster/ dry wall

FOR DIRECT ATTACHMENT TO LOAD BEARING CONCRETE

ONLY! Concrete expansion anchors are not intended forattachment to concrete ceilings covered with a layer of plaster,drywall, or other finishing material. If mounting to concrete

ceiling covered with plaster / drywall is unavoidable, plaster / drywall must be counterbored as shown below.

concreteceiling

concreteanchor

concreteanchor

concrete

anchor

F

F

F

Illustration A

Installation to Concrete CeilingsAlligator ® concrete anchors are recommended

concreteanchor

G

2

G

CONCRETE CEILING

Page 5: Sp Ceil 011 Inst Sheet

7/30/2019 Sp Ceil 011 Inst Sheet

http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 5/7

ISSUED: 1-5-04 SHEET #: 055-9196-1

Visit the InFocus Web Site at www.infocus.com

5 of 7

Screw extension column to ceiling plate (G).Align the notch with one of the four holes in

the ceiling plate (G) and secure extensioncolumn with a M5 x 10 mm socket pinscrew (C) using security allen wrench (B).

See detail 3.

Screw extension column connector (I) to

extension column. Align slot in extensioncolumn with one of the top holes in

extension column connector (I). Insert andtighten one 10-32 x 3/8 socket pin screw (J)through extension column connector (I) into

slot on extension column using securityallen wrench (B). See detail 4.

Screw ball and socket mount (A) toextension column connector (I). Align slot in

ball and socket mount (A) to one of the

bottom holes in extension column connector(I). Insert and tighten one 10-32 x 3/8 socketpin screw (J) through extension columnconnector into slot in ball and socket mount

(A) using security allen wrench (B).

Note: Slotted set screw (K) is used to jamagainst the threads of the ball and socketmount to prevent any excess movement ofthe ball and socket mount (A). Do not over-tighten screw; over- tightening screw willdamage threads making it difficult toseparate the products.

DETAIL 6

A

EXTENSIONCOLUMN

SLOT

I

J

SLOT

SLOT

EXTENSIONCOLUMN (SOLD

SEPARATELY)

G

I

DETAIL 4

EXTENSIONCOLUMN

SLOT

I

J

DETAIL 3

EXTENSIONCOLUMN

CG

Installation toExtension Column

A

K

Page 6: Sp Ceil 011 Inst Sheet

7/30/2019 Sp Ceil 011 Inst Sheet

http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 6/7

ISSUED: 1-5-04 SHEET #: 055-9196-1

Visit the InFocus Web Site at www.infocus.com

6 of 7

Flip projector upside down. Find your projector from the models listed below. Using the holes indicated on thecorresponding hole pattern diagram, attach adapter plate (L) to projector using three M4 x 16 mm serrated washer

head socket pin screws (M) and three .198 x .313 x .375 retaining spacers (O).Notes:

Retaining spacers go between adapter plate and projector.* Notch indicates front of projector.** Projectors using hole pattern G use one M4 x 12 mm screw (N) and one .198 x .313 x .187 retaining spacer (P)

where indicated.

A. C200, C420, DP6500X, DP8200X,LP650, LP820, SP7200, SP7205

* * *

***

*

**

B. C40, C50, DP2000S/X, LP240,LP250

D. C100, C105, DP6150, DP6155,

LP690

E. C110, DP8000, LP790,

SP4800, SP4805, X1, X2

F. C170, LP600

C. LP340, LP350, LP500, LP530,SP110

G. C160, C180, LP540, LP640

Page 7: Sp Ceil 011 Inst Sheet

7/30/2019 Sp Ceil 011 Inst Sheet

http://slidepdf.com/reader/full/sp-ceil-011-inst-sheet 7/7

ISSUED: 1-5-04 SHEET #: 055-9196-1

Visit the InFocus Web Site at www.infocus.com

7 of 7

WARNING: Do not lift more weight than you can handle!

Use additional man power or mechanical lifting

equipment to safely handle placement of the projector!

To adjust roll, pitch, and yaw loosen the set screw

(shown below) using security allen wrench (B) or

standard 4 mm allen wrench. You should be able to

 just slightly loosen the screw so that your adjustments

can be set without having to hold the projector. Moveprojector to desired position and slowly tighten set

screw.

Note: Be sure not to touch the projector while

tightening the set screw. This may cause the image

to be unaligned when you let go.

IMPORTANT: Allen wrench is your key for projector

removal. Store it in a safe place.

Note: The projector you are installing may differ in appearance from the sample illustrated below.

 © 2004 Peerless Industries, Inc. All rights reserved.

Peerless is a registered trademark and Armor Lock is a trademark of Peerless Industries Inc.All other brand and product names are trademarks or registered trademarks of their respective owners.

SET SCREW

Attach projector to the ball and socket mount (A) by

inserting the ball and socket mount (A) into the

adapter plate connection and twisting until the adapter

plate will no longer turn (about 75°). The spring loaded

captive screw should line up with a correspondinghole on the adapter plate (this should line up auto-

matically when the two are connected). Push down

and tighten the spring loaded captive screw to secure

the adapter plate to the mount. If not using the optional

security feature, fasten thumb screw (D) in the hole

opposite the spring loaded captive screw.

OPTIONAL: For Armor Lock™ security, insert serrated

washer head socket pin security screw (E) in the hole

opposite the spring loaded captive screw. Tighten with

security allen wrench (B). This will prevent the

projector from being removed.

Note: Be sure to only use the 10-32 x 3/8" screw (E)(or the thumb screw (D)) opposite the spring loaded

captive screw.

A

WOODJOIST

CEILING

PROJECTOR ADAPTER PLATE

PROJECTOR

WOODJOIST

CEILING

PROJECTOR

E

2

1

D

CAPTIVE

SCREW