Upload
api-3808778
View
476
Download
2
Embed Size (px)
Citation preview
Product and ApplicationSourcebookAC and DC blowers performing within the air flow range of 0-1800 SCFM, pressures to10 PSIG and vacuums to14 IHG.
• Instrument Grade and Variable Flow Blowers
• Industrial Blowers • Environmental Blowers • Chemical Processing Blowers • High Pressure Blowers • Remote Drive Blowers • Specialty Blowers • Accessories
Serving over one hundred applications and diverseindustries by providing high quality industry-specificproducts and technical assistance.
Your Choice.Our Commitment.TM
R E G E N E R A T I V E B L O W E R S
MULTIFLOW™ DCBLOWER SUMMARY
AIR FLOW - SCFM
INC
HE
S O
F W
AT
ER
22
20
18
16
14
12
10
8
6
4
2
PS
IG
0.75
0.50
0.25
0 10 20 30 40 50
MF573
MF501
MF571MF301
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 2
Performance Curves for Variable Flow Blowers – Brushless DC
MINISPIRAL™BLOWER SUMMARY
AIR FLOW - SCFM
INC
HE
S O
F W
AT
ER
22
20
18
16
14
12
10
8
6
4
2
PS
IG
0.75
0.50
0.25
0 1 2 3 4 5 6 7 8 9
HDC
MDC
REVAFLOW™BLOWER SUMMARY
AIR FLOW - SCFM
INC
HE
S O
F W
AT
ER
30
25
20
15
10
5
PS
IG
1.00
0.75
0.50
0.25
0 10 20 30
R304
R2504
R205
D1508
Minispiral™ MDCSE12V21-037433 (9-15 VDC)SE24V21-037434 (24-32 VDC)
Minispiral™ HDCSE12RE21-038700 (7.5-15 VDC)SE24RE21-080257 (24-32VDC)
Revaflow™ D1506PE12N-080395 (7-12 VDC)R205PE12N-037785 (7-12 VDC)R2504 PE12N-080399 (7-12 VDC)R304PE12N-080401 (7-12 VDC)
M I N I S P I R A L ™
R E V A F L O W ™
Multiflow™DC MF301DC06-080428 (3-6 VDC)MF301DC12-080429 (7-12 VDC)MF301DC24-080430 (18-24 VDC)MF501DC12-080378 (7-12 VDC) *MF501DC24-080379 (18-24 VDC) *MF571DC24-080392 (18-24 VDC) *MF573DC24-080380 (18-24 VDC) *
M U LT I F L OW ™ D C
* Requires External Controller for operation
For other available voltage options consult your local Field Sales Engineer.
Performance Curves for Variable Flow Blowers – Brushless AC
MULTIFLOW™BLOWER SUMMARY
250W/120V & 400W/240V
INC
HE
S O
F W
AT
ER
80
70
60
50
40
30
20
10
PS
IG2.5
2.0
1.5
1.0
.5
AIR FLOW - SCFM
0 20 40 60 80 100 120
MF573BS
MF573ES
MF571BSMF572BH & MF572EH
MF571BH & MF571EH
MULTIFLOW™BLOWER SUMMARY
800W/120V & 1200W/240V
INC
HE
S O
F W
AT
ER
160
140
120
100
80
60
40
20
PS
IG
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
.5
AIR FLOW - SCFM
0 30 60 90 120 150 180
MF573KS
MF573HS
MF572HH
MF571HH
MF572KH
MF571KH
Multiflow™ 250 Watt – 120 Volt Models
MF571BS2M-080343*MF571BH2M-080345*MF572BH2M-080347*MF573BS2M-080351*
Multiflow™ 400 Watt – 240 Volt Models
MF571EH3M-080355*MF572EH3M-080357*MF573ES3M-080363*
Multiflow™ 800 Watt – 120 Volt Models
MF571HH2M-080365*MF572HH2M-080367*MF573HS2M-080369*
Multiflow™ 1200 Watt – 240 Volt Models
MF571KH3M-080371*MF572KH3M-080373*MF573KS3M-080376*
M U L T I F L O W ™
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 3* Mechanical speed adjustment models shown. All models available with electronic speed control option.
Performance Curves for Regenerative Blowers Below 4.0 PSIG – 0 to 230 SCFM
FLOW RATE – SCFM
INCH
ES O
F W
ATER
PSIG
140
130
120
110
100
90
80
70
60
50
40
30
20
10
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 2500
0 1 2 3 4
4
3
2
1
SCFM
INCH
ES O
F W
ATER
A
N
O
P
E DH
C
K
G
F
IJ
B
L
M
Q
PRESSURE CURVES(Shown for 60 Hz; 50 Hz data
available on request.)
A SE 2B (AC)B SL 2C SL 4D SL 5
E DR 068F DR 083G DR 101
H DR 202I DR 303J DR 353
K DR 404L DR 513M DR 454
N DR 505O DR 555P DR 606Q DR 6
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 4
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 5
Performance Curves for Regenerative Blowers Below 7.0 IHg – 0 to 230 SCFM
FLOW RATE – SCFM
INCH
ES O
F W
ATER
INCH
ES O
F M
ERCU
RY
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
-120
-110
-100
-90
-80
-70
-60
-50
-40
-30
-20
-10
9
8
7
6
5
4
3
2
1
0 1 2 3 4
4
3
2
1
SCFM
INCH
ES O
F W
ATER
0
E
D
H
C
K
G
F
I
A
J
B
L
M
N
O
P
Q
SUCTION CURVES(Shown for 60 Hz; 50 Hz data
available on request.)
A SE 2B (AC)B SL 2C SL 4D SL 5
E DR 068F DR 083G DR 101
H DR 202I DR 303J DR 353
K DR 404L DR 513M DR 454
N DR 505O DR 555P DR 606Q DR 6
Performance Curves for Regenerative Blowers Below 5.0 PSIG – 100 to 1800 SCFM
FLOW RATE – SCFM
INCH
ES O
F W
ATER
PSIG
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700
BB
CC
140
130
120
110
100
90
80
70
60
50
40
30
20
10
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5 AA
DD
EE
GG
FF
HH
PRESSURE CURVES(Shown for 60 Hz; 50 Hz data
available on request.)
AA DR 707BB DR 808
CC DR 858DD DR P9
EE DR 909FF DR P13
GG DR 14HH DR P15
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 6
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 7
Performance Curves for Regenerative Blowers Below 8.0 IHg – 50 to 1800 SCFM
AA DR 707BB DR 808
CC DR 858DD DR P9
EE DR 909FF DR P13
GG DR 14HH DR P15
FLOW RATE – SCFM
INCH
ES O
F W
ATER
INCH
ES O
F M
ERCU
RY
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700
-120
-110
-100
-90
-80
-70
-60
-50
-40
-30
-20
-10
9
8
7
6
5
4
3
2
1
AA
BB
CC
DD
EE
GG
FF
HH
SUCTION CURVES(Shown for 60 Hz; 50 Hz data
available on request.)
Performance Curves for Regenerative Blowers Above 5.0 PSIG – 50 to 900 SCFM
FLOW RATE – SCFM
INCH
ES O
F W
ATER
PSIG
PRESSURE CURVES(Shown for 60 Hz; 50 Hz data
available on request.)
280
260
240
220
200
180
160
140
120
100
80
60
40
20
10
9
8
7
6
5
4
3
2
1
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850
HPB
HPA
HPD
HPC
HPE
HPG
HPF
HPH
HPK
HPI
HPJ
HPA DR 523HPB DR S543HPC DR 623
HPD DR S7HPE DR 823HPF DR S75
HPG DR S85HPH DR S9HPI DR 1223
HPJ DR S13HPK DR S15
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 8
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 9
Performance Curves for Regenerative Blowers Above 8.0 IHg – 0 to 900 SCFM
FLOW RATE – SCFM
-180
-160
-140
-120
-100
-80
-60
-40
-20
14
12
10
8
6
4
2
INCH
ES O
F W
ATER
INCH
ES O
F M
ERCU
RY
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850
HSA
HSB
HSD
HSC
HSE
HSG
HSF
HSH
HSK
HSI
HSJ
SUCTION CURVES(Shown for 60 Hz; 50 Hz data
available on request.)
HSA DR 523HSB DR S543HSC DR 623
HSD DR S7HSE DR 823HSF DR S75
HSG DR S85HSH DR S9HSPI DR 1223
HSJ DR S13HSK DR S15
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 10
CCoonnssuulltt yyoouurr llooccaall FFiieelldd SSaalleess EEnnggiinneeeerr ttoo rreeqquueesstt oouurr ccoommpplleettee ccaattaalloogg ffoorr iinndduussttrriiaall pprroodduucctt ssppeecciiffiiccaattiioonnss aanndd aapppplliiccaattiioonnss..
Photo Weight X Length Y Width Z Height Inlet/OutletBlowers 3 Index (lbs.) (Inches) (Inches) (Inches) Connections 1
MINISPIRALTM
SE 2B (AC) A 1 1.7 4.1 4.2SE 12V, 24V A 1 1.7 4.1 4.2 0.75"OD-S.O.SE 12RE B 1 2.7 4.1 4.2
NAUTILAIR TM
NC 33 C 13 11.5 7.0 10.9 5.0"OD-S.O.
SPIRALTM
SL 2 D 27 7.9 10.0 10.0 1.75"OD-S.O.SL 4,5 E 43 9.3 10.0 10.0
REVAFLOWTM
D 1506 F 0.6 2.8 3.0 2.9 1.03"x1.05"-S.O.R 205 G 0.6 3.4 2.8 2.9 0.812"OD-S.O.R 2504 G 0.6 4.4 2.7 3.3 0.812"OD-S.O.R 304 H 0.8 4.0 2.8 4.5 1.71"x0.68"-S.O.
MULTIFLOWTM
MF301 I 1.0 2.9 2.5 2.7 0.81"OD-S.O.MF501 I 1.1 5.0 3.0 5.0 0.88"OD-S.O.MF571 J 4 5.9 6.7 6.1 1.25"OD-S.O. 2
MF572 J 5 5.9 6.7 7.1 1.25"OD-S.O. 2
MF573 J 6 5.9 6.7 7.8 1.25"OD-S.O. 2
Full Product Dimensional Listing
B C D
JG H
XY
Z
Y X
Z
XY
Z
Y
Z
X
E
Y
Z
XY
Z
X Y
Z
Y
Z
X
F I
Z
X
A
Z
X
Y
Y
X
1 SO-Slip On 2 1.75"OD-S.O. for high flow models 3 Remote drive available on Multiflow model
Photo Weight X Length Y Width Z Height Inlet/OutletBlowers 3 Index (lbs.) (Inches) (Inches) (Inches) Connections 1
DRXOXDR 068 K 8 6.0 6.3 6.7 1.0"OD-S.O.DR 083 K 12 6.7 7.3 7.8 1.0"OD-S.O.
DR/EN/CPXOXDR/EN/CP 101 K 26 11.2 7.2 8.2 1"NPSC-FDR/EN/CP 202 K 29 11.4 8.9 9.5 1"NPSC-FDR/EN/CP 303 K 36 12.6 9.6 10.2 11/4"NPSC-FDR/EN/CP 353 K 56 11.9 11.0 11.5 11/4"NPSC-FDR/EN/CP 404 K 61 14.4 11.6 12.2 11/2"NPSC-FDR/EN/CP 454 K 73 14.6 12.6 13.5 11/2"NPSC-FDR/EN/CP 513 K 87 12.8 12.8 15.9 11/2"NPSC-FDR/EN/CP 505 K 82 14.7 13.5 14.5 11/2"NPSC-FDR/EN/CP 555 K 95 17.1 14.4 15.1 11/2"NPSC-FDR/EN/CP 606 K 108 17.0 14.8 15.6 2"NPSC-FDR/EN/CP 6 L 133 18.1 16.4 16.7 2"NPSC-FDR/EN/CP 707 K/ M 156 18.2 16.3 16.7 21/2"NPSC-FDR/EN/CP 808 K/ M 201 23.1 18.8 21.1 21/2"NPSC-FDR/EN/CP 858 M / K 258 24.0 18.6 21.8 21/2"NPSC-FDR/EN/CP 909 M / K 426 24.3 19.6 23.0 4"NPSC-FDR/EN/CP 14 M 767 30.0 23.4 27.0 4"NPSC-F
DR/EN/CP High PressureDR/EN/CP 523 K 118 18.5 14.2 15.9 11/2"NPSC-FDR S543 N 172 26.0 12.8 17.4 2"NPSC-FDR/EN/CP 623 K 180 22.0 16.5 17.5 2"NPSC-FDR S7 N 185 23.1 16.4 17.4 2"NPT-FDR/EN/CP 823 K 300 21.8 20.5 21.8 3"NPSC-FDR S75 N 230 23.3 16.3 17.0 2"NPSC-FDR S85 N 280 30.7 18.7 20.5 21/2"NPSC-F 2
DR S9/P9 N 420 31.5 18.0 21.0 21/2"NPT-FDR/EN/CP 1223 K 400 28.1 20.5 22.1 4"NPSC-FDR S13/P13 N 687 36.0 19.6 23.3 3"NPT-F 2
DR S15/P15 N 1025 39.0 23.4 28.0 4"NPT-F 2
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 11
Full Product Dimensional Listing
K L
Y
Z
X Y
Z
X
M
Y
Z
X Y
Z
X
N
3 Remote drives available on DR/EN/CPXOX Models. Contact factory for other dimensions and sizes.
2 DR P9 has 4"OD-SO outletDR P13 has 4"NPSC-F outletDR P15 has 6"NPSC-F outlet
1 SO-Slip OnF-Female ThreadM-Male ThreadNPSC-National Pipe Straight CourseNPT-National Pipe Taper
Base Mount Rail Mount Rail Mount Duplex Rail Mount
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 12
Blower Accessories
Filtration AccessoriesInlet and Inline Filters• Inlet filters protect the blower and the air distribution system from dust, and other
airborne particles and contaminants. Normally used in pressure systems. Inline filters protect the blower from harmful dust and other particles that may be drawn into theblower through the air distribution system. (8 -10 micron standard – others available)
Filter Silencers and Elements• Inlet filter/silencers reduce noise levels while ensuring clean air is provided to the blower
and the air distribution system. Normally used in pressure applications. All Rotron air filters and filter/silencers have replaceable filter elements. The filter media is polyesterdesigned for high efficiency over a wide spectrum of industrial applications.
Moisture Separator™• By separating and containing entrained liquids, Rotron’s moisture separator helps protect
our regenerative blowers and the end treatment system from corrosion and mineralizationdamage. Recommended for all soil vacuum extraction applications.
Measurement AccessoriesAir Flow Meter (Analog, 4-20 mA, Digital Readout)• Measures air flow rates to aid in the balance of multi-pipe systems, detect channeling
or plugging of a line and allow system fine tuning for optimal performance. An optional4-20 mA output can be used to achieve systems with fully automated flow control. Digital readouts in SCFM also available.
Gauges and Relief Valves• Rotron has a variety of gauges for pressure, vacuum and temperature measurements
in various ranges. These gauges are reliable and rugged. The relief valve is installed to prevent excessive system pressure or vacuum that could result from line restrictions.
Noise Reduction AccessoriesInlet and Inline Mufflers• Inlet/outlet mufflers lower blower noise in areas where reduced sound levels are required.
Inline mufflers are utilized for noise reduction in applications where piping systems are connected directly to both ends of the muffler.
Protection AccessoriesAir Flow Switch• Rotron’s air flow switch sends a control signal in response to increasing or decreasing
velocity of the air stream. Useful in automatically initiating process controls, wanning systems on as an interlock for on-off purposes.
Explosion-Proof Motor Starter• The National Electric Code requires the use of starters with explosion-proof motors
equipped with pilot duty thermal overload protection. These UL & CSA approved explosion-proof starters protect the blowers from electrical malfunctions.
Pressure/Vacuum/Temperature Switches• Our adjustable switches can automatically initiate equipment shutdown, alarm systems
or interlocking machine functions to insure that blower output parameters stay withinprocess specifications.
System AccessoriesAir Knives• The Rotron air knife is located at a strategic point in your assembly line conveyor belt area.
Air flows from the blower outlet through a pipe and into the air knife plenum, where asheet of air is directed out through a proprietary linear nozzle design onto assembly lineparts. This system can be used for cleaning parts, drying, or blowing back particles and liquids.
Diverter Valves• These unique solenoid actuated diverter valves automatically change air piping from
pressure to suction; greatly enhancing blower versatility and productivity. This valve iseffective in blower applications that require frequent switching of air from pressure to suction and vice-versa.
Eductors• Eductors expand blower versatility and can be used effectively in conjunction with
Rotron regenerative blowers to boost air or gas to create material handling systems inwhich the conveyed material does not pass through the blower, and to create low or noflow suctions exceeding the suction from a blower alone.
Air Flow Meter
Filter
ReliefValve
Explosion-ProofMotor Starter
Gauge
Moisture Separator TM
Air Knife
Air Flow Switch
Diverter Valve
Muffler
Application 1: Air-Assisted Breathing
MMaannuuffaaccttuurriinngg PARP Respiration
MMiinniinnggPARP Respiration
Your own imagination and knowledge are probably the best source of in-plant and on-site applications for Rotron regenerative blowers. The remaining sections of this guide will help to pinpoint and stimulate your consideration of themany alternative sources we provide to replace costly and maintenance intensive suction and pressure units and systems.
The nine major application groups are listed and a cross reference of most common applications by industry will helpyou identify both identical and similar applications in your industrial operations.
Application 2: Air-Assisted Inflation or Support
MMaatteerriiaall HHaannddlliinnggAir SlidesAir TablesCarbon Black Car Unloading
PPaappeerr PPrroocceessssiinnggFlotation TablesForming BarSheet FlutteringTurn Bars
TTeexxttiilleeGarment Flotation Tables
WWaatteerr PPoolllluuttiioonn CCoonnttrroollPollution ContainmentWaterway Management
Nine Major Blower Application Areas
Application 3: Air-Assisted Vacuum Pick-Up or Hold-Down
MMaannuuffaaccttuurriinnggBag Filling EquipmentCutting TablesPackaging EquipmentVacuum Manipulators
PPaappeerr oorr PPllaassttiiccss HHaannddlliinnggCutting TablesDiaper Making EquipmentPrinting Presses
TTeexxttiilleeGarment Cutting TablesYarn Guiding and TensioningYarn AspirationYarn Stringup
FLOTATION TABLES
TURNING & FORMING BARSAIR SLIDES/AIR TABLES
GENERAL PART PICK-UP GENERAL PART HOLD-DOWN
NOSE MOUTH THROAT
VACUUM MANIPULATOR CUTTING & PRINTING HOLD-DOWN TABLE
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 13
BLOWER
BLOWER
BLOWER
BLOWER
BLOWER
BLOWER
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 14
Application 6: Gas, Vapor & Fume Recovery, Venting & Treatment
AAggrriiccuullttuurraallMethane Gas Recovery
CChheemmiiccaall PPrroocceessssiinnggVent Header Off-Gassing
EEnnvviirroonnmmeennttaallGasoline Vapor RecoveryLagoon Gas RecoveryLandfill Gas RecoveryRadon Gas CollectionSoil Vapor Extraction
FFoouunnddrryyLost Foam Off-Gassing
MMaannuuffaaccttuurriinngg -- PPllaanntt SSeerrvviicceessCabinet Fume VentingEnvironmental Test Chamber VentingLaser Smoke RemovalWeld Smoke Removal
Application 5: Electronic Cooling
IInnssttrruummeennttaattiioonnEngine/Motor CoolingFilm Development System CoolingLamp Bank CoolingSmall Enclosure Cooling
Nine Major Blower Application Areas
Application 4: Air & Gas Sampling, Boosting or Circulating
AAiirr PPoolllluuttiioonn CCoonnttrroollAir SamplingAir Stream Release MonitoringFire Prevention Air SamplingFlue Gas Sampling
FFoouunnddrryyCombustion Air Boost
IInnssttrruummeennttaattiioonnGlove Box PressurizingIncubator Air CirculationWeather Measurement Sampling
MMaannuuffaaccttuurriinnggCombustion Air BoostNatural Gas BoostOil Demisting
PPhhaarrmmaacceeuuttiiccaallClean Room Air CirculationOxygen Generator
PPllaassttiiccss HHaannddlliinnggDesiccant Dryer Bed Regeneration
FLUID BED REGENERATION TRANSMISSOMETER LENS PURGING
COMBUSTION AIR BOOST
NATURAL GAS BOOST AIR & GAS SAMPLING
PRESSURIZED CABINET VACUUM PULL-THROUGH CABINET
SOIL VAPOR EXTRACTION & LANDFILL GAS RECOVERY VENT HEADER OFF-GASSING
FUME & SMOKE REMOVAL DIGESTER GAS COLLECTION
PPhhaarrmmaacceeuuttiiccaallSterilization Gas (ETO)
Recovery
RReeffiinneerriieessCentrifuge Venting
WWaatteerr PPoolllluuttiioonn CCoonnttrroollDigester Gas Collection
BLOWERBLOWER
BLOWER
BLOWER BLOWER
BLOWER
BLOWER
BLOWERBLOWER
BLOWER
BLOWER
Application 8: Parts Blow-Off & Drying
AAqquueeoouuss PPrreecciissiioonn CClleeaanniinnggAutomotive Parts DryingSemiconductor Board Drying
FFoooodd PPrroocceessssiinnggBatter Blow-OffBottle & Can DryingLabel DryingSalt, Spice & Flour Blow-Off
Application 9: Solution & Media Agitation & Aeration
AAqquuaaccuullttuurreeAquarium, Fish Farm, Hatchery & Pond Aeration
EEnnvviirroonnmmeennttaallGroundwater Sparging
MMaannuuffaaccttuurriinnggConcrete Fluid Bed AerationElectroplating Tank Agitation
MMaatteerriiaall HHaannddlliinnggFluidized Beds
RReeccrreeaattiioonnCommercial Spa Aeration
WWaatteerr MMaannaaggeemmeennttBoat, Dock & Dam Face Deicing
WWaatteerr PPoolllluuttiioonn CCoonnttrroollUV Tube AgitationWastewater Filter BackwashWastewater Treatment Tank Aeration
Nine Major Blower Application Areas
MMaannuuffaaccttuurriinnggConveyor Belt Blow-OffElectroplating Fume GuidingElectroplating Part DryingElectroplating Solution
Blow-BackFlat or Irregular Metal Port
DryingWire Drying
Application 7: Solid Material Transporting, Separation &Collection
FFoouunnddrryySand Reclamation
MMaannuuffaaccttuurriinngg --WWaassttee CCoonnttrroollChip, Dust & Particle RemovalLiquid & Solvent RemovalPaper, Plastic, Film & Textile (Trim) Removal
MMaatteerriiaall HHaannddlliinnggAir SlidesBlast CleaningDilute Phase ConveyingPneumatic Tube
PPaacckkaaggiinnggBag Filling
DILUTE PHASE PNEUMATIC CONVEYING PNEUMATIC TUBE
PAPER, PLASTIC, FILM & TEXTILE(TRIM) REMOVAL
GENERAL MATERIAL SEPARATION& COLLECTION
GENERAL PARTS BLOW-OFF & DRYING SOLUTION BLOW-BACK
WASTEWATER TREATMENT TANK AERATION GROUNDWATER SPARGING
ELECTROPLATING TANK AERATION COMMERCIAL SPA AERATION
BIN PAD & FLUIDIZED BED AERATION BOAT & DOCK DEICING
75 North Street, Saugerties, NY 12477e mail: [email protected] • internet: www.rotrontmd.com
Page 15
PRESSUREBLOWER
BLOWER
BLOWERBLOWER
BLOWERBLOWER
BLOWER
BLOWER
BLOWER
BLOWERBLOWER
BLOWER
R E G E N E R A T I V E B L O W E R S
YourChoice.OurCommitment.™For further application assistance, or to request AMETEK Rotron’s Complete Product Catalog, please contact the above listed Field
Sales Engineer for your area. For assistance outside of North America contact the factory for more information.
75 North St., Saugerties, NY 12477 • e mail: [email protected] • internet: www.rotrontmd.com • Phone: (914) 246-3401 • FAX: (914) 246-3802Copyright © 1998 10M 11/98
http://www.ametektmd.com/fieldsales.htm
For Up to Date Rep Listing, Please Visit:
Factory Representation – North America