Upload
chcrr
View
19
Download
3
Tags:
Embed Size (px)
DESCRIPTION
Operating procedures of Turbine
Citation preview
ESSAR POWER (ORISSA) LTD 4 X 30 MW CPP
Revision No : 00TURBINE SOP
Doc No: EPOrL / COMMISSIONING
ESSAR POWER (ORISSA) LIMITED
2X30 MW CPP, PARADEEPStandard operating procedureSteam Turbine
INDEX
SR NO.CONTENTSPAGE
1INTRODUCTION 2
2TECHNICAL SPECIFICATION3-9
3SAFETY CHECKLIST10
4COOLING WATER AND AUX COOLING WATER CHARGING11-12
5OIL SYSTEM START UP12-14
6.BARRING GEAR START UP14-15
7TURBINE AUXILLIARY EQUIPMENT START UP15-16
8STEAM LINE CHARGING AND VACCUM BUILD UP16-18
9DEFINITION OF HOT, COLD STARTUP18-20
10TURBINE COLD STARTUP AND SYNCHRONIZATION 21-25
11TURBINE RE START FROM WORK CONDITION26
12TURBINE PROTECTION AND INTERLOCKS27-28
1. INTRODUCTION
The purpose of the Turbine system is to convert the heat energy in the steam from generator into kinetic energy & to drive the TG train.
The SST300 C160 Turbine is a single flow turbine with 15 stage & downward exhaust. When admission steam reaches the turbine, it first passes through an emergency shut off valve (ESV) with steam strainer & then continues to a control valve. A hydraulic servomotor controls the steam valve.
G.A. DAIGRAM
2 TECHNICAL SPECIFICATION
Design Data Make :Siemens Limited Type of Turbine : Single cylinder, single flow exhaust, Non-reheat, condensing Model :SST300 C-160 No. of stage :15 Rotor blade type :Impulse/reaction Rotor weight :4750 Kg Distance between brg centers :2798 mm Journal dia. (NDE bearing):179.63 mm Journal dia. (DE bearing):199.67 mm
Turbine Output Rated :32.450 MW
Speed Rated (Turbine):7059 RPM (100%) Rated (Generator) :1500 RPM (100%) Emergency Trip (Turbine) :7765 RPM (110%) First Critical Speed :3460 RPM
Direction of Rotation Seen Turbine Generator :CCW (Counter clock wise)
Live Steam Pressure Rated :63 Ata Temperature Rated :460C Flow :124.49 TPH
Exhaust To Condenser Pressure :0.100Ata Temperature :45.5C Flow :112.46 TPH
Bleed 1 Pressure :3.71 Ata Temperature :140.5C Flow :12.03 TPH
CONDENSER: (Thermal Design) Design data Make :Siemens Limited Type : Single Pressure, Two Pass, Under Slung, Circular surface condenser Condensing Surface Area :3290 m2 Cleanliness Factor:85% No. of Passes :2 Plugging Margin :5% Cooling Water Velocity :2.07 m/s Pressure Drop :