Est. 1994 1600 East 78th St. Richfield, MN 55423 (612)866-1200 (800)466-7946 US, Canada, Mexico www.ecosmarte.com www.glasspackfilter.com Solve ODOR and ALGAE Problems in Car Wash Reclamation Systems By: Larry Couture The addition of a simple ECOsmarte electronics package to the existing water treatment equipment with a glass media filter will enhance separation of oils and solids as well Municipal regulation of new car wash construction requiring reclamation systems has created specific challenges in water treatment with most sites experiencing noxious odors and algae growth on the walls due to the reclamation water. ECOsmarte oxygenation/ionization systems have been installed since 1999 in Michigan, Maine and Minnesota with specific success utilizing the existing water treatment equipment onsite. Installation time for the average six bay wash has been accomplished in less than 2 hours. The DC voltage controller, self sacrificing copper anodes and titanium/platinum oxygenation anodes operate at a cost of about $50 per bay, per year with 30 minutes of quarterly maintenance. In 2009, the addition of low pressure, high flow rate glass media filtration has been engineered to better separate solids using the glass and oxygen in a swimming pool sand filter platform. On each site the algae build-up on the walls stopped (in both summer and winter) and the odor has been virtually eliminated. The algae itself is often a source of the odor but the reclamation sump is the ultimate culprit with soaps, minerals, dirt and plant spores creating an optimal environment. Source water dissolved oxygen (DO) levels are increased from 2 to 3ppm to 6.0 to 6.5 range ppm and a low level copper ionization level of .2 to .4ppm is maintained through both programmable and flow switch controllers. The increases in DO are true in both hot and cold water, and regardless of ph. Maintenance personnel maintain the copper residual with a simple Lamotte EC 70 test kit, a 5 drop reagent and quarterly cleaning of the anodes in a diluted acid wash. The reclamation system can be installed as part of a new car wash build or added to all existing water treatment strategies. Copyright 2009 ECOsmarte Pools, Spas and Water, Inc.

Solve ODOR and ALGAE Problems in Car Wash Reclamation …

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Solve ODOR and ALGAE Problems in Car Wash Reclamation …

Est. 1994

1600 East 78th St. Richfield, MN 55423(612)866-1200 (800)466-7946 US, Canada, Mexico

www.ecosmarte.comwww.glasspackfilter.com

Solve ODOR and ALGAE Problems in Car Wash Reclamation SystemsBy: Larry Couture

The addition of a simple ECOsmarte electronics packageto the existing water treatment equipment with a glassmedia filter will enhance separation of oilsand solids as well

Municipal regulation of new car wash constructionrequiring reclamation systems has created specificchallenges in water treatment with most sites experiencing noxious odors and algae growth on thewalls due to the reclamation water.

ECOsmarte oxygenation/ionization systems havebeen installed since 1999 in Michigan, Maine andMinnesota with specific success utilizing the existingwater treatment equipment onsite. Installation timefor the average six bay wash has been accomplishedin less than 2 hours. The DC voltage controller, selfsacrificing copper anodes and titanium/platinum oxygenation anodes operate at a cost of about $50per bay, per year with 30 minutes of quarterly maintenance.

In 2009, the addition of low pressure, high flow rateglass media filtration has been engineered to better separate solids using the glass and oxygen in aswimming pool sand filter platform.

On each site the algae build-up on the walls stopped(in both summer and winter) and the odor has been virtually eliminated. The algae itself is often a sourceof the odor but the reclamation sump is the ultimate culprit with soaps, minerals, dirt and plant sporescreating an optimal environment.

Source water dissolved oxygen (DO) levels areincreased from 2 to 3ppm to 6.0 to 6.5 range ppmand a low level copper ionization level of .2 to .4ppmis maintained through both programmable and flowswitch controllers. The increases in DO are true inboth hot and cold water, and regardless of ph.

Maintenance personnel maintain the copper residualwith a simple Lamotte EC 70 test kit, a 5 dropreagent and quarterly cleaning of the anodes in adiluted acid wash.

The reclamation system can be installed as part of anew car wash build or added to all existing water treatment strategies.

Copyright 2009 ECOsmarte Pools, Spas and Water, Inc.

Page 2: Solve ODOR and ALGAE Problems in Car Wash Reclamation …

Est. 1994

TECHNICAL SPECIFICATIONS

1600 East 78th St. Richfield, MN 55423(612)866-1200 (800)466-7946 US, Canada, Mexicowww.ecosmarte.comwww.glasspackfilter.com

MECHANICAL & PLUMBINGOperating Press. Max. 150 PSIGOperation Temp. Max. 120˚ FTank listing and structural integrityrequirements only.

OXYGEN ELECTRODESProprietary composite material

IONIZATION ELECTRODES100% Pure Copper

ELECTRICALInput Voltage: 110 to 267 Volts, SpecifyOutput Voltage: 100 VA Class UL CSA

Compliance Power SupplyGPM: Each Unit 5 GPM to 200 GPM

Multiple Bay Systems May Require MoreThan One Electronics Package.

ECOsmarte and Glass Pack Filter are registered US Trademarks of ECOsmarte Planet Friendly, Inc. in over 26 countries

Existing bag filters may or may not be used,depending on existing water treatment.

Ozone or UV Bulb replacement will generallynot be required after installing an ECOsmarte Package.