69
Solution-16 Operators Manual ISSUE 1.40

Solution-16 Operators Manual - ADT Security · Solution-16 Operators Manual 11 Electronics Design & Manufacturing Pty Limited ISSUE140.DOC. Controls & Indicators The Codepad The codepad

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

  • Solution-16Operators Manual

    ISSUE 1.40

  • Solution-16Operators Manual

    Copyright 1995-97 by Electronics Design & Manufacturing Pty Limited,SYDNEY, AUSTRALIA

    Document Part Number MA880ODocument Issue 1.40Printed 29 July 1997

    This documentation is provided to suit the Solution-16 Control Panel (CC880/LP880)Firmware Revision 1.30 - 1.40

    Hardware Revision F

    Copyright NoticeAll rights reserved. No part of this publication may be reproduced, transmitted or stored in aretrieval system in any form or by any means, electronic, mechanical, photocopying, recording, orotherwise, without the prior written permission of Electronics Design and Manufacturing PtyLimited.

    TrademarksThroughout this document trademark names may have been used. Rather than put a trademarksymbol in every occurrence of a trademark name, we state that we are using the names only in aneditorial fashion and to the benefit of the trademark owner with no intention of infringement ofthe trademark.

    Notice of LiabilityWhile every precaution has been taken in the preparation of this document, neither ElectronicsDesign & Manufacturing Pty Limited nor any of its official representatives shall have any liabilityto any person or entity with respect to any liability, loss or damage caused or alleged to be causeddirectly or indirectly by the information contained in this book.

    Electronics Design & Manufacturing Pty Limited reserves the right to make changes to featuresand specifications at any time without prior notification in the interest of ongoing productdevelopment and improvement.

  • Table of Contents

    INTRODUCTION .................................................................................................................... 9

    FEATURES............................................................................................................................. 10

    BASIC SYSTEM OPERATION ............................................................................................ 11

    CONTROLS & INDICATORS.............................................................................................. 12The Codepad...........................................................................................................12Zone Indicators........................................................................................................12AWAY Indicator.......................................................................................................12STAY Indicator.........................................................................................................12MAINS Indicator.......................................................................................................13FAULT Indicator .....................................................................................................13Audible Indicators ....................................................................................................13LCD Codepad Indicators .........................................................................................14Codepad Functions .................................................................................................15Code Retries............................................................................................................15Codepad Lockout Time............................................................................................16Codepad Extinguish Mode.......................................................................................16Alarm Memory..........................................................................................................16

    SYSTEM OPERATIONS....................................................................................................... 17Arming In AWAY Mode............................................................................................17

    Forced Arming ...................................................................................................17Disarming From AWAY Mode............................................................................17

    Arming In STAY Mode 1 ..........................................................................................18Disarming From STAY Mode 1 ..........................................................................19

    Arming In STAY Mode 2 ..........................................................................................19Disarming From STAY Mode 2 ..........................................................................20

    Isolating Zones ........................................................................................................21Code Only To Isolate .........................................................................................21Standard Isolating..............................................................................................21

    User Codes..............................................................................................................22User Code Priority Level....................................................................................220 Arming & Disarming ........................................................................................221 Arming Only ....................................................................................................222 Patrolman Code..............................................................................................224 Arming/Disarming + Code To Isolate..............................................................226 Patrolman Code + Code To Isolate ................................................................228 Arming/Disarming + Master Code Functions ..................................................2312 Arming/Disarming + Master Code Functions + Code To Isolate...................23

    Auxiliary Codes........................................................................................................23Auxiliary Code Priority Level..............................................................................23

    Day Alarm ................................................................................................................24Day Alarm Resetting ..........................................................................................24Day Alarm Latching............................................................................................24Operation ...........................................................................................................24

    Codepad Duress Alarm ...........................................................................................25Codepad Panic - (Versions Up To 1.36)..................................................................25Codepad Panic - (Version 1.37 Onwards) ...............................................................25Codepad Fire Alarm - (Version 1.37 Onwards) .......................................................25

  • Codepad Medical Alarm - (Version 1.37 Onwards)................................................. 25Entry Time ............................................................................................................... 26Exit Time ................................................................................................................. 26Sensor Watch Time................................................................................................. 26System Date and Time ............................................................................................ 26Automatic Arming .................................................................................................... 27Automatic Operation of an Output........................................................................... 27

    SPECIAL FUNCTIONS......................................................................................................... 28Master Code Functions ........................................................................................... 28

    0 Arming and Disarming All Areas - Partitioned Systems Only ......................... 281 Changing & Deleting User Codes .................................................................. 29

    Auxiliary Codes ....................................................................................................... 302 Changing Domestic Phone Numbers ............................................................. 313 Event Memory Recall ..................................................................................... 324 Walk Test Mode ............................................................................................. 335 Turning Outputs On and Off ........................................................................... 346 Setting The Date and Time............................................................................. 357 Reserved ........................................................................................................ 358 Setting STAY Mode 2 Zones .......................................................................... 369 Reserved ........................................................................................................ 36

    User Code Functions - Partitioned Systems Only ................................................... 370 Arming and Disarming All Areas..................................................................... 37

    Hold Down Functions .............................................................................................. 38# Arm The System In AWAY Mode ................................................................... 38* Arm The System In STAY Mode 1 .................................................................. 380 Arm The System In STAY Mode 2.................................................................. 381 Horn Speaker Test ......................................................................................... 382 Bell Test ......................................................................................................... 383 Strobe Test ..................................................................................................... 394 Turning Day Alarm On and Off ....................................................................... 395 Fault Analysis Mode ....................................................................................... 396 Initiate A Modem Call ..................................................................................... 407 Reset Latching Outputs.................................................................................. 408 Codepad ID and Beeper Tone Change.......................................................... 409 Initiate A Test Report...................................................................................... 41

    Fault Descriptions ................................................................................................... 41To Determine The Type Of Fault....................................................................... 41To Acknowledge The Fault................................................................................ 41

    System Faults.......................................................................................................... 421 Low Battery..................................................................................................... 422 Date and Time................................................................................................ 423 Sensor Watch................................................................................................. 424 Horn Speaker Disconnected........................................................................... 425 Telephone Line Fault ..................................................................................... 426 E2 Fault .......................................................................................................... 427 Zone 16 In Alarm - Partitioned Systems Only ................................................ 428 Communications Failure................................................................................. 42AC Mains Failure............................................................................................... 42

  • PARTITIONING .................................................................................................................... 43Master Partitioned Codepad Indicators ...................................................................43

    1 Zone Indicators ...............................................................................................432 Area ON/OFF Indicators .................................................................................433 Area Display Indicators...................................................................................434 Status Indicators .............................................................................................43Aux Indicator......................................................................................................43Mains Indicator ..................................................................................................43Fault Indicator ....................................................................................................43Partial Indicator..................................................................................................43

    Operation Of Codepads In Partitioning....................................................................44Operating From Area “Addressable” Codepads ................................................44Operating From A “Master Partitioned” Codepad ..............................................44

    COMMUNICATION OPTIONS ........................................................................................... 45Options and Accessories ...................................................................................45

    REMOTE FUNCTIONS ........................................................................................................ 46Remote Arming Using The Phone Controller ..........................................................46

    Operation ...........................................................................................................46

    OPERATING THE SYSTEM USING A TOUCH TONE TELEPHONE ........................... 47Operation.................................................................................................................47

    To Establish A Communication Link With Your Alarm System(Non Partitioned System)...................................................................................47To Establish A Communication Link With Your Alarm System(Partitioned System) ..........................................................................................47To Terminate The Link With Your Alarm System...............................................47

    Domestic Tone Reporting ........................................................................................48Operation Of Domestic Tone Reporting ...........................................................48Programming Domestic Phone Numbers...........................................................49Disabling Domestic Dialling ...............................................................................49

    Domestic Voice Message Reporting........................................................................50Operation of Domestic Voice Message Reporting .............................................50Programming Domestic Phone Numbers...........................................................50

    Pager Reporting ......................................................................................................51Alpha Pager Reporting ............................................................................................51Using The PET Alpha Pocket Pager Format ...........................................................52Basic Pager Reporting.............................................................................................53

    Operation Of Basic Pager Reporting .................................................................53

    OPTIONAL EQUIPMENT .................................................................................................... 54EDMSAT - Satellite Siren ..................................................................................54Additional Codepads..........................................................................................54Night Arm Station...............................................................................................54Radio Remote Control .......................................................................................54Phone Controller................................................................................................54Hand Held Radio Remote Control Panic Button ................................................54Smoke Detectors ...............................................................................................54Photoelectric Beams..........................................................................................55Passive Infrared Detectors ................................................................................55Magnetic Reed Switches ...................................................................................55Glass Break Detectors.......................................................................................55Vibration Detectors ............................................................................................55Communications Dialler .....................................................................................55

  • Telephone Line Fault Monitor ........................................................................... 55Securitel ............................................................................................................ 55Telephone Line Fault Module............................................................................ 55

    GLOSSARY OF TERMS....................................................................................................... 56

    WARRANTY.......................................................................................................................... 59Warranty Statement ................................................................................................ 59Limitations ............................................................................................................... 59Maintenance............................................................................................................ 59Specifications .......................................................................................................... 60Advice To Users ...................................................................................................... 60New Zealand Telepermit Notes............................................................................... 60Quality Policy .......................................................................................................... 61

    INSTALLATION NOTES ..................................................................................................... 62

  • IntroductionCongratulations on selecting the Solution-16 control system to protect you and yourproperty. So that you can obtain the most from your unit, we suggest that you take the time toread through this manual and familiarise yourself with the numerous outstanding operatingfeatures of this system.

    You will notice that in all aspects of planning, engineering, styling, operation, convenience andadaptability, we have sought to anticipate your every possible requirement. Programmingsimplicity and speed have been some of the major considerations and we believe that ourobjectives in this area have been more than satisfied.

    This manual will explain all aspects of operating the control panel. All system parameters andoptions are detailed, however suitability is left up to the individual. Every system can be tailoredto meet all requirements quickly and easily.

    The Solution range of control panels is very popular with thousands of people throughoutmany countries of the globe, all of whom have various levels of technical aptitude and ability. Wehave tried to aim this manual at all levels of readers.

    As Solution has continued to be improved over the years, it has become very powerful. Someof its early first-time users have advanced to true “power users” and we need to address theirneeds too, while maintaining the simplicity of the manual and the product.

    This operators manual is intended for BOTH the Solution-16 Dialler (CC880) and theSolution-16 Local (LP880) control panels. If you have a local panel (LP880), disregard allreferences and features in this manual which involve telephone dialling.

    Solution-16 Operators Manual 9

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • FeaturesThe Solution-16 security control system uses the very latest in microprocessor technology toprovide you with more useful features and superior reliability and performance.

    Following is a list of some of the features and why they will be of benefit to you.

    • Operating codes may be up to seven digits long. This allows for a far greater combination ofcodes and therefore a higher degree of security.

    • Dynamic battery testing continually tests and monitors the stand-by battery’s condition. Asbatteries do not last forever, this feature will warn you of a poor battery condition before analarm occurs.

    • Day alarm warning allows you to monitor the opening of a front door in a shop or to prohibitaccess into a particular area while the system is still disarmed.

    • Remote arming is a unique feature that allows you to arm your system from any telephone inthe world. This is very useful if you forget to arm your system.

    • The built in telephone dialler will alert you or your monitoring station of any alarm or adverseevent 24 hours a day. This highly sophisticated communications system is capable ofidentifying and reporting many different events. For further information, please contact yourinstaller.

    • All of the system configuration information is stored in non volatile memory which means thatmany of the options can be programmed on site by the installer to best suit your needs. Thisdata is retained even when the power to the system is disconnected.

    • STAY mode allows you to arm the system with predetermined areas disabled. This means thatyou can arm your system at night while you are still at home thus giving you personalprotection.

    Note: One option that can be programmed by your installer will prevent another installer ortechnician from performing any service to your system. This should be discussed withyour installer.

    Refer to “Optional Equipment” on page 54 for more details on accessories and other features thatcan be used with your system.

    10 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • Basic System OperationThe overall purpose of your alarm system is to deter any would be intruder from entering yourpremises.

    Before leaving your home or office, make sure all windows and doors are closed. Enter your

    designated followed by the button. Your alarm system will now arm andcommence counting down the exit time.

    After the exit time expires, you will hear a long beep at the remote codepad. Any unsealed zoneswill be automatically isolated. The control panel is now ready to activate the sirens and strobelights should any alarm occur.

    If a zone that is sealed has triggered after exit time has expired, a number of events will occur.Following is a typical sequence of events.

    1. The control panel will activate any audible devices such as sirens, flashing blue strobe lightand the communications dialler if fitted and enabled.

    2. The communication dialler will transmit all relevant alarm information via the telephone line

    alerting the respective persons of the current state of events. 3. The siren timer will commence counting down as soon as an alarm occurs. When the siren

    run time expires, the siren will automatically turn off and be placed into a ready state for thenext alarm.

    4. Upon your return, the blue strobe light may still be operating to inform you that there has

    been an alarm. 5. One or a number of zone indicators will be flashing, allowing you to identify the particular

    zone(s) that caused the alarm condition. This is a very basic outline of the general system operation. As there are many features availablein the Solution-16 control panel, there could be numerous variations from the abovesequence.

    Solution-16 Operators Manual 11

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Controls & IndicatorsThe Codepad

    The codepad is the communications interfacebetween you and your control panel. It allows youto issue commands and offers both visual andaudible indications that guide you through thegeneral operation.

    The codepad incorporates numerous indicators.There are zone indicators which are used to showthe condition of each zone and four others forgeneral status. The following is a list of situationsand the relevant indications that will be seen.

    Figure 1: CP5 Codepad

    Zone IndicatorsThe zone indicators are used to show the status of the zones. The following table lists the variouscircumstances that the indicators will display (ie. Zone sealed, zone unsealed).

    Indicator DefinitionOn Zone Is UnsealedOff Zone Is Sealed

    Flashing Fast(0.25 sec on - 0.25 sec off)

    Zone Is In Alarm Condition

    Flashing Slow(1 sec on - 1 sec off)

    Zone Is Manually Isolated

    Table 1: Zone Indicators

    AWAY IndicatorThe AWAY indicator is used to inform you that the system is armed in the AWAY mode.

    Indicator DefinitionOn System Is Armed In The AWAY ModeOff System Is Not Armed In The AWAY Mode

    Table 2: AWAY Indicator Functions

    STAY IndicatorThe STAY indicator is used to indicate that the system is armed in the STAY mode.

    Indicator DefinitionOn System Is Armed In The STAY ModeOff System Is Not Armed In The STAY Mode

    Flashing System Is In ISOLATE Mode OrSTAY Mode 2 Zones Are Being Set

    Table 3: STAY Indicator Functions

    12 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • MAINS IndicatorThe MAINS indicator is used to indicate that the systems AC mains power is normal or has failed.

    Indicator DefinitionOn AC Mains Power Normal

    Flashing AC Mains Power Failure

    Table 4: MAINS Indicator Functions

    FAULT IndicatorThe FAULT indicator is used to indicate that the system has detected a fault. Refer to “FaultDescriptions” on page 41 for more details as you may need to contact your installer.

    Indicator DefinitionOn There Is A System Fault That Needs To Be RectifiedOff The System Is Normal There Are No Faults

    Flashing There Is A System Fault Waiting To Be Acknowledged

    Table 5: FAULT Indicator Functions

    There are however some modes of operation such as changing user codes where the FAULTindicator is used to represent the number '20'. This should not be considered as a fault butinterpreted as intended, according to the current mode of operation.

    Audible IndicatorsIn general the audible indications given out by the codepad are as follows.

    Indicator DefinitionOne Short Beep A Button On The Codepad Has Been Pressed

    Two Short Beeps The System Has Accepted Your CodeThree Short Beeps The Requested Function Has Been Executed

    One Long Beep Indicates End Of Exit Time OrThe Requested Operation Has Been Denied Or Aborted

    One Short Beep Every Second Walk Test Mode Is Currently Active OrWarning Before Automatic Arming Takes Place

    One Short Beep Every Minute There Is A System Fault Waiting To Be Acknowledged

    Table 6: Audible Indications

    Solution-16 Operators Manual 13

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • LCD Codepad IndicatorsEDM is committed to providing functional and aesthetically pleasing user interfaces and we feelthat our unique Icon LCD codepads have met this objective.

    The icon codepads provide full zone status indication at all times as well as a number of specialicons which indicate such things as system armed, system disarmed, mains fail, system fault andnumerous other system functions.

    The following table outlines all of the indicators which will be found on thecodepads. A description of the various operating modes is also provided.

    Zone Indicators

    1 2 3 ….

    The ZONE indicators (1-8 on CP508L and 1-16 on CP516L)show the status of each zone.Illuminated = Zone Unsealed Flashing = Zone In AlarmOff = Zone Sealed

    Mains Indicator The MAINS Icon indicates the status of the AC mains powersupply.Illuminated = AC Mains OK Flashing = AC MainsDisconnected or fault

    Armed In AWAYMode

    The AWAY Icon illuminates when the system is armed in theAway mode. The indicator will also illuminate when in theAway mode.

    Armed In STAYMode

    The STAY Icon illuminates when the system is armed in the Staymode. The and indicators will also illuminate when in theStay mode.

    System Disarmed The Disarmed Icon illuminates when the system is fullydisarmed. The indicator will also illuminate when in thedisarmed state.

    Zone IsolatingMode

    This indicator will illuminate when in Zone Isolating Mode.The person will flash once every 3 seconds.

    Fault Indicator The FAULT Icon will illuminate if the system has a faultcondition.Steady = A fault has been acknowledged. Flashing = A newfault has occurred. Off = No faults have occurred.

    ProgrammingMode

    Flashing

    This indicator will illuminate when the system is in anyprogramming mode.

    Both persons will flash.

    Off Indicator /Zone Unsealed

    The OFF Icon will illuminate when the system is in the disarmedstate and will flash when a zone becomes unsealed. It will stopflashing when all zones are sealed.

    On Indicator /Zone In Alarm

    The ON Icon will illuminate when the system is armed in theAway mode and will flash when an alarm occurs. The indicatorwill reset once a valid user code is entered.

    14 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • Codepad FunctionsThe following pages will describe how to use and interpret the many codepad functions that areavailable on the Solution-16 control panel.

    Most functions are performed using the Master Code. Refer to “Master Code Functions” on page28 for more information.

    Before attempting to enter any of the Master Code functions, ensure that the system is in thedisarmed state and that there are no alarm memory indicators flashing. If this is not the case thefollowing will be required.

    • If the zone indicators are flashing fast, enter your followed by the button.

    • If the system becomes armed (ie. The AWAY indicator is illuminated), enter your followed by the button. This will place the system back into the disarmed state.

    • If the system is not disarmed (ie. The AWAY or STAY indicators are illuminated), enter your followed by the button.

    The factory default Master Code is 2580. This code can be changed at any time. Thereforeif your system Master Code differs from the default, please substitute your existing Master Codein the following examples.

    This code allows you to change any users code and even the Master Code itself. It is also theonly code that allows the execution of special functions as detailed later in this manual.

    Code RetriesCode retries restricts the amount of times an invalid user code can be used in an attempt tooperate the system. An alarm caused by this is known as a “Codepad Tamper Alarm”. When acodepad tamper alarm occurs, the system will carry out the following events;

    1. Activate the sirens and strobe connected to the control panel. Contact your installer if yourequire this to be silent.

    2. Shutdown all codepads that are connected and automatically disable them from operating

    the system. The length of time they are disabled for is programmed by your installer. 3. Send an “Access Denied” report to the base station receiver (Optional).

    This function works when the system is in the armed or disarmed state. Each time the system isarmed or disarmed the code retry counter is reset. The number of incorrect code attempts can beanywhere between 1 to 15. This value is programmed by your installer. Refer to “InstallationNotes” on page 62 for the number of code retries set by your installer.

    Solution-16 Operators Manual 15

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Codepad Lockout TimeThe codepad will be locked out for the time programmed by your installer if the wrong code hasbeen entered more times than allowed by the code retry attempts.

    Codepad Extinguish ModeThis option when programmed by your installer will cause the indicators on your codepad toautomatically extinguish if the codepad is not used for a period of sixty seconds.

    The indicators will illuminate once a button has been pressed on the remote codepad. Theindicators will also illuminate when an alarm occurs or when the system is in entry time. Theindicators will not illuminate if a silent alarm is triggered. This option can only be programmed byyour installer.

    Alarm MemoryIf when you return to your premises you notice the strobe light flashing, then care should be takenas this means that there has been an alarm condition while you were away.

    When you enter the building and turn the system off, you will notice one or a number of zoneindicators flashing rapidly. This indicates that the zone(s) in question have triggered into alarm.

    If the zone indicator is flashing fast (On 0.25 sec/Off 0.25 sec), then this indicates that one of the16 burglary zones has gone into alarm. You should take note of this information so that it can bepassed onto your installer should they require it.

    It is also possible to interrogate your alarm system using the “Event Memory Recall” function.This will allow you or your installer to interpret the exact sequence of events that occurred. Referto “Event Memory Recall” on page 32 for more information.

    16 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • System OperationsArming In AWAY ModeThere are two methods for arming your system in the AWAY mode. Method one is standard andwill always operate. Method two is optional and needs to be programmed by your installer. Referto your “Installation Notes” on page 62 to check if method two has been enabled.

    Method One• To Arm Your System In AWAY Mode.

    Enter your followed by the button.Two beeps will be heard and the AWAY indicator will illuminate. Exit time will now begin.

    +

    Method Two• To Arm Your System In AWAY Mode

    Hold the button down until two beeps are heard.The AWAY indicator will illuminate and exit time will now begin.

    If a zone is not sealed at the end of exit time it will be automatically isolated. It will become anactive part of the system again as soon as it is sealed (ie. If a window is opened during exit time,the window will not be an active part of the system until it is closed. Opening the window afterthis time will cause an alarm condition).

    Forced ArmingThe feature of arming the system when a zone is not sealed is known as forced arming. If thisfeature is not suitable, your installer can program your control panel so that it will not arm unlessall zones are sealed.

    If the AWAY indicator does not illuminate and a long beep is heard, forced arming is notpermitted. If this is the case, you must ensure that all zones are sealed or manually isolated beforeyou will be allowed to arm the system.

    Disarming From AWAY Mode

    • To Disarm Your System From AWAY ModeEnter your followed by the button.Two beeps will be heard and the AWAY indicator will extinguish. A flashing zone indicatorrepresents a previous alarm on that zone.

    +

    Solution-16 Operators Manual 17

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Arming In STAY Mode 1STAY mode 1 is when the system has been armed with particular zones automatically isolated.These zones must be programmed by your installer.

    When there is a need to arm only the perimeter of your building, this mode is extremely handy. Itautomatically disables the interior detection zones allowing for movement within the protectedarea while at the same time arming the perimeter zones.

    There are two methods for arming your system in STAY mode 1. Method one is standard and willalways operate. Method two is optional and needs to be programmed by your installer. Refer to“Installation Notes” on page 62 for your method of arming in STAY mode 1.

    Method One• To Arm Your System In STAY Mode 1

    Enter your followed by the button.Two beeps will be heard and the STAY indicator will illuminate. Any zones that have beenprogrammed for STAY mode 1 will be automatically isolated and their respective indicators willbegin to flash until exit time expires. At the end of exit time the zone indicators willextinguish.

    +

    Method Two• To Arm Your System In STAY Mode 1

    Hold the button down until two beeps are heard.The STAY indicator will illuminate and any zones that have been programmed for STAY mode 1will be automatically isolated and their respective indicators will begin to flash until exit timeexpires. At the end of exit time the zone indicators will extinguish.

    If a zone is not sealed at the end of exit time it will be automatically isolated. It will become anactive part of the system as soon as it is sealed (ie. If a window is opened before the end of exittime, it will not be an active part of the system until it is closed. Opening the window after thistime will cause an alarm condition).

    The feature of arming the system when a zone is not sealed is known as forced arming. If thisfeature is not suitable, your installer can program your system so that it will not arm unless allzones are sealed.

    If the STAY indicator does not illuminate and a long beep is heard, forced arming is not permitted.If this is the case, you must ensure that all zones are sealed or manually isolated before you will beallowed to arm the system.

    18 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • Disarming From STAY Mode 1

    Method One• To Disarm Your System From STAY Mode 1

    Enter your followed by the button.Two beeps will be heard and the STAY indicator will extinguish. A flashing zone indicatorrepresents a previous alarm on that zone.

    + Method Two• To Disarm Your System From STAY Mode 1

    Hold the button down until two beeps are heard.The STAY indicator will extinguish. If your system does not disarm and you see a flashing zoneindicator, method one will need to be used. Method two does not operate after an alarm hasoccurred.

    Arming In STAY Mode 2STAY mode 2 is when the system has been armed with particular zones automatically isolated. AnyMaster Code user can program these zones before the system can be armed in STAY mode 2.Refer to “Master Code Functions” on page 28 for details on how to program zones for STAYmode 2.

    When there is a need to arm the perimeter of your building, this mode is extremely handy. Itautomatically disables the interior detection zones allowing for movement within the protectedarea while at the same time arming the perimeter zones.

    • To Arm Your System In STAY Mode 2

    Hold the 0 button down until two beeps are heard.The STAY indicator will illuminate and any zones that have been programmed for STAY mode 2will be automatically isolated and their respective indicators will begin to flash until exit timeexpires. At the end of exit time the zone indicators will extinguish.

    00If a zone is not sealed at the end of exit time it will be automatically isolated. It will become anactive part of the system as soon as it is sealed (ie. If a window is opened before the end of exittime, it will not be an active part of the system until it is closed. Opening the window after thistime will cause an alarm condition).

    The feature of arming the system when a zone is not sealed is known as forced arming. If thisfeature is not suitable, your installer can program your system so that it will not arm unless allzones are sealed.

    If the STAY indicator does not illuminate and a long beep is heard, forced arming is not permitted.If this is the case, you must ensure that all zones are sealed or manually isolated before you will beallowed to arm the system.

    Solution-16 Operators Manual 19

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Disarming From STAY Mode 2

    Method One• To Disarm Your System From STAY Mode 2

    Enter your followed by the button.Two beeps will be heard and the STAY indicator will extinguish. A flashing zone indicatorrepresents a previous alarm on that zone.

    + Method Two• To Disarm Your System From STAY Mode 2

    Hold the 00 button down until two beeps are heard.The STAY indicator will extinguish. If your system does not disarm and the codepad has aflashing zone indicator, method one will need to be used. Method two does not operate afteran alarm has occurred.

    00

    20 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • Isolating ZonesWhen a zone is isolated, access is allowed into that zone at all times. Isolating zones is performedby one of two methods. One way requires the use of a valid user code while the other way doesnot. The ability to isolate zones is governed by the priority level allocated to each user codeholder. Some user code holders may not be able to isolate zones. Refer to “Installation Notes” onpage 62 for your method of isolating.

    Twenty four hour zone types and zones not used cannot be isolated. If isolation of these zones isattempted a long beep will be heard.

    Code Only To Isolate

    To Isolate Zones1. Press the button.2. Enter your .3. Press the button. Three beeps will be heard.

    4. * Enter the you require to be isolated.5. Press the button.

    6. * Enter the you require to be isolated.7. Press the button.8. Press the button when finished. Two beeps will be heard.

    Isolated zone indicators will continue to flash. The system is ready to be armed.

    + + + + + + +

    Standard Isolating

    To Isolate Zones1. Press the button.2. Press the button again. Three beeps will be heard.

    3. * Enter the you require to be isolated.4. Press the button.

    5. * Enter the you require to be isolated.6. Press the button.7. Press the button when finished. Two beeps will be heard.

    Isolated zone indicators will continue to flash. The system is ready to be armed.

    + + + + + +

    * As each zone is isolated, the corresponding zone indicator will begin to flash. If a mistake is

    made, re-enter the zone number that was incorrectly entered followed by the button.This zone will no longer be isolated and the zone indicator will stop flashing.

    Solution-16 Operators Manual 21

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • User CodesThe purpose of user codes is to arm and disarm the system as well as perform other specificfunctions as described in “Master Code Functions” on page 28.

    User codes can be any length from one to seven digits long. Each user code can have a differentpriority level allocated to it. This controls the behaviour of the code, allowing it to arm only or toarm and disarm etc. Discuss this further with your installer.

    User Code Priority LevelThere are seven different priority levels that can be allocated to user codes 1 - 32. Each prioritylevel allows or restricts the functions that different user codes can perform.

    Note: Once user code priority levels 4, 6 and 12 have been enabled to any of the available 32user codes, the method of “Standard Isolating” will no longer operate. Only those usercodes with the priority level of 4, 6 and 12 will be able to isolate zones using the method“Code To Isolate”.

    Priority Level Description0 Arming & Disarming1 Arming Only2 Patrolman Code4 Arming/Disarming + Code To Isolate6 Patrolman Code + Code To Isolate8 Arming/Disarming + Master Code Functions

    12 Arming/Disarming + Master Code Functions + Code To Isolate

    Table 7: User Code Priority Levels

    0 Arming & DisarmingThis level allows the user code to arm and disarm the system only.

    1 Arming OnlyThis level allows the user to arm the system but not disarm it. Resetting an alarm which hasoccurred during the disarmed state (ie. A 24 hour zone) is also allowed.

    2 Patrolman CodeA Patrolman Code will allow you to issue a user code which will only disarm after an alarmhas occurred. This will prevent unauthorised use of the code. A Patrolman Code can alwaysarm the system.

    4 Arming/Disarming + Code To IsolateIsolating of zones will only be allowed by using the method “Code To Isolate” once thispriority level has been set. Standard Isolating will be disabled for all user code holders.This level also allows arming and disarming of your system.

    6 Patrolman Code + Code To IsolateThis level allows a user with a Patrolman Code to disarm the system once an alarm hasoccurred. Isolating Zones will only be allowed by using the method “Code To Isolate” oncethis priority level has been set. Standard Isolating will be disabled for all user code holders.A Patrolman Code can always arm the system.

    22 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • 8 Arming/Disarming + Master Code FunctionsMaster Code functions will be accessible to any code having this priority level selected.More than one code can be allocated to this priority level. This priority level also allowsarming and disarming of the system. Refer to page 28 for further information regarding“Master Code Functions”.

    12 Arming/Disarming + Master Code Functions + Code To IsolateMaster Code functions will be accessible to any code having this priority level selected.More than one code can be allocated to this priority level. This priority level also allowsarming and disarming of the system. Isolating zones will only be allowed by using themethod “Code To Isolate” once this priority level has been set. Standard Isolating will bedisabled for all user code holders. Refer to page 28 for further information regarding“Master Code Functions”.

    PriorityLevel Arm Disarm

    PatrolmanCode

    StandardIsolate

    MasterCode

    Code ToIsolate

    0 ü ü ü 1 ü ü 2 ü ü ü 4 ü ü ü 6 ü ü ü 8 ü ü ü ü

    12 ü ü ü ü

    Table 8: User Code Priorities

    Auxiliary CodesAuxiliary codes can be used to operate a device via one of the programmable outputs available inyour system. An auxiliary code could be used to unlock a door that is fitted with an electric strikeor to turn on and off security lighting. There is an unlimited number of uses for auxiliary codesand your installer can program these to suit your requirements. Refer to “Installation Notes” onpage 62.

    There are two auxiliary codes available in your system and these can be any length from one toseven digits long. The priority level controls the behaviour of the code, allowing it to operatewhen the system is armed or disarmed etc.

    Auxiliary Code Priority Level

    Number Priority Level1 Work When System Is Armed2 Work When System Disarmed4 Work Always As Long As No Alarm Memories Are Present5 Work If Armed & No Alarm Memories Are Present6 Work If Disarmed & No Alarm Memories Are Present7 Work If Armed Or Disarmed & No Alarm Memories Are Present

    Table 9: Auxiliary Code Priority Level

    Solution-16 Operators Manual 23

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Day AlarmThis may be useful to monitor the front door of a shop or a pool gate. Day alarm enables acombination of zones to be monitored while the system is in the disarmed state. An indication isavailable via any of the programmable outputs including the codepad buzzer. Only zones 1 - 8may be used as day alarm monitored zones. Refer to “Installation Notes” on page 62 to checkwhich zones have been allocated to operate for day alarm.

    Day Alarm ResettingAn output that is programmed as Day Alarm Resetting will operate when a zone selected for dayalarm is triggered. The output will reset when the zone returns to normal. This can only occur ifthe system is disarmed.

    Day Alarm LatchingAn output that is programmed as Day Alarm Latching will operate when a zone selected for day

    alarm is triggered. The output will reset when the button is pressed. This can only occurwhen the system is disarmed.

    OperationDay Alarm is turned on and off by holding the 4 button down for two seconds. Refer to “HoldDown Functions” on page 38 for more details. Three beeps means day alarm is turned on, twobeeps means day alarm is turned off.

    If a zone has been programmed for day alarm, it can be isolated in the normal way. The isolatedzone will not register as a day alarm.

    Example

    If you have multiple zones programmed for day alarm and one of them is triggered, it is difficultto know which zone caused the day alarm. Using a latching day alarm will solve the problem.When a day alarm trigger occurs, all zone indicator's are turned off leaving only the zone or zones

    that caused the day alarm illuminated. To clear the memory, press the button.

    24 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • Codepad Duress AlarmA codepad duress alarm can be used as a hold up alarm. This will occur when the number 9 isadded to the end of any valid user code that is being used to disarm the system. Adding a 9 tothe end of a code when arming the system will not cause a duress alarm. A codepad duress alarmis always silent and can only be made use of if your control panel is reporting back to amonitoring station or pocket pager.

    + 9 + Codepad Panic - (Versions Up To 1.36)A codepad panic alarm will occur when any two outside buttons in the same horizontal row on acodepad are pressed simultaneously. This is an audible alarm. Discuss this with your installer ifyou require the panic alarm to be silent.

    1 3 or 4 6 or 7 9 or

    Codepad Panic - (Version 1.37 Onwards)A codepad panic alarm will occur when either the two outside buttons 1 and 3 or and

    on the same horizontal row on a codepad are pressed simultaneously. This is an audiblealarm. Discuss this with your installer if you require the panic alarm to be silent.

    1 3 or

    Codepad Fire Alarm - (Version 1.37 Onwards)A codepad fire alarm will occur when the 4 and 6 buttons on the codepad are pressedsimultaneously. This is an audible alarm. Discuss this with your installer if you require thecodepad fire alarm to be disabled. A distinct fire sound is emitted through the horn speaker toindicate this type of alarm condition. This fire sound is different to the burglary sound.

    4 6

    Codepad Medical Alarm - (Version 1.37 Onwards)A medical alarm will occur when the 7 and 9 buttons on the codepad are pressedsimultaneously. This is an audible alarm. Discuss with your installer if you require the medicalalarm to be disabled.

    7 9

    Solution-16 Operators Manual 25

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Entry TimeEntry time is the amount of time allowed to disarm your system after you have opened the firstentry delay zone. During the entry time, the codepad buzzer will beep twice per second warningyou to disarm your system. If you do not disarm your system before the entry time expires, analarm will be activated. Refer to “Installation Notes” on page 62 for the programmed entry timeset by your installer.

    Exit TimeExit time is the amount of time you have to leave your premises after you have entered your codeto arm the system. You will hear a long beep from the codepad to indicate the end of exit time.Make sure you exit your premises before this time expires. Refer to “Installation Notes” on page62 for the programmed exit time set by your installer.

    Sensor Watch TimeSensor watch is part of control panel’s watchdog circuitry. It is a feature designed to ensure thatall your detection devices are working correctly.

    Sensor watch time determines how many days (0-99) a zone may remain sealed before registeringas a fault. This feature is only active while the system is in the disarmed state because while yoursystem is armed, the detection devices are on stand-by waiting to be activated.

    If a zone programmed for sensor watch has not triggered and reset during this time, the FAULTindicator will illuminate and the codepad will beep once every minute. To cancel the codepad

    beeping once every minute, press the button. Refer to “Fault Descriptions” on page 41for more information. Refer to “Installation Notes” on page 62 to check if “Sensor Watch Time”has been programmed by your installer..

    System Date and TimeThe control panel has a real time 12 month calendar and 24 hour clock that needs to be set andchanged for daylight savings. This will allow the system to log events and send test reports withaccurate time stamping if programmed. Refer to “Master Code Functions” on page 28 for moreinformation.

    26 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • Automatic ArmingThis feature is used to automatically arm your system in the AWAY mode or STAY mode 1 at thesame time every day. Refer to your “Installation Notes” on page 62 to see if your system willautomatically arm in the AWAY mode or in STAY mode 1. Your auto arm warning time is listedhere as well.

    Warning Time Before Auto ArmingThis is the time period before your system will automatically arm. The codepad will beep onceevery second until the warning time has expired, after which the system will arm and the exit timewill commence. If you do not wish your system to arm when you hear the pre alert warning,enter your user code to extend the auto arming time by one hour.

    Automatic Operation of an OutputYour installer can program your system to turn on devices such as your air conditioner, lights orpool filter at the same time every day.

    Warning Time Before An Output OperatesThis is the time period before your system will automatically operate a piece of equipment. Thecodepad will beep once every second until the warning time has expired.

    If you do not wish your system to operate the piece of equipment when you hear the pre alertwarning, enter your code to extend the time before the operating time of the output by one hour.

    Solution-16 Operators Manual 27

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Special FunctionsMaster Code FunctionsMaster Code functions are designed to allow those users that have the appropriate priority levelto perform certain supervisory functions. These functions can only be carried out while thesystem is in the disarmed state.

    When changing or deleting user codes it is important that you know the number of the user youwish to change or delete. Your installer should provide you with this information at the time ofinstallation.

    Note: The default Master Code is 25802580 and is known as User 1. It is possible for thissystem to have multiple Master Codes. Please check with your installer as to how yoursystem is configured.

    + +

    Function Description0 Arming and Disarming All Areas - Partitioned Systems Only1 Changing & Deleting User Codes2 Changing Domestic Phone Numbers3 Event Memory Recall Mode4 Walk Test Mode5 Turning Outputs On and Off (* = Off # = On)6 Setting The Date and Time7 Reserved8 Setting Zones For STAY Mode 29 Reserved

    Table 10: Master Code Functions

    0 Arming and Disarming All Areas - Partitioned Systems OnlyThis option allows you to arm or disarm all areas at the same time that you belong to. Allareas will arm or disarm to follow the state of the area that the code was entered from (ie. Ifyou disarm an area, all other areas will disarm, or, if you arm an area, all other areas willarm as well).

    This allows the user to ensure that all areas will be armed by pressing one extra buttonrather than entering the user code at each area codepad.

    To Arm Or Disarm All Area At The Same Time

    1. Enter your followed by 0 and the button.Two beeps will be heard.

    + 0 +

    28 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • 1 Changing & Deleting User Codes

    Changing User CodesThis function allows a Master Code holder to add or change a user code.

    To Add or Change A User Code

    1. Enter your followed by 1 and the button. Three beeps will be heard and the STAY and AWAY indicators will begin to flash.

    2. Enter the (1-32) that you wish to add or change followed by the button. Two beeps will be heard and the corresponding zone indicator will

    illuminate. Refer to “Table 11: Indicators For User Numbers” on page 30.

    3. Enter the digits required for the followed by the button. Two beeps will be heard and the STAY and AWAY indicators will extinguish.

    If a long beep is heard then the code you are trying to create is already in the system.

    + 1 + + + + +

    Deleting User CodesThis function allows a Master Code holder to delete any of the system user codes.

    To Delete A User Code

    1. Enter your followed by 1 and the button. Three beeps will be heard and the STAY and AWAY indicators will begin to flash.

    2. Enter the (1-32) that you wish to delete followed by the button. Two beeps will be heard and the corresponding zone indicator will illuminate.Refer to “Table 11: Indicators For User Numbers” on page 30.

    3. Press the button to delete the user code.Two beeps will be heard and the STAY and AWAY indicators will extinguish.

    If you wish to erase any further codes, repeat this procedure as many times as required.

    + 1 + + + +

    Note: When changing or deleting user codes, the code change mode will automatically

    terminate if a button is not pressed within sixty seconds. Pressing the buttonwill also terminate the session at any time.

    Solution-16 Operators Manual 29

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Auxiliary CodesAuxiliary Codes one and two are treated as user codes thirty three and thirty four respectively.To alter auxiliary codes one or two, follow the same procedure as explained in “Master CodeFunction - Changing & Deleting User Codes” on page 29.

    One long beep in the code alteration mode indicates an error. An error will occur if the codeentered already exists or an incorrect user number was selected.

    Indicators For Changing CodesUserNo

    Zone 1Light

    Zone 2Light

    Zone 3Light

    Zone 4Light

    Zone 5Light

    Zone 6Light

    Zone 7Light

    Zone 8Light

    MAINSLight

    FAULTLight

    1 ü 2 ü 3 ü 4 ü 5 ü 6 ü 7 ü 8 ü 9 ü ü

    10 ü 11 ü ü 12 ü ü 13 ü ü 14 ü ü 15 ü ü 16 ü ü 17 ü ü 18 ü ü 19 ü ü ü 20 ü 21 ü ü 22 ü ü 23 ü ü 24 ü ü 25 ü ü 26 ü ü 27 ü ü 28 ü ü 29 ü ü ü 30 ü ü 31 ü ü ü 32 ü ü ü 33 ü ü ü 34 ü ü ü

    Table 11: Indicators For User Numbers

    30 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • 2 Changing Domestic Phone NumbersThis option allows a Master Code holder to view and program the required telephonenumbers that the system will call in the event of an alarm. This option is only applicable ifyour system is programmed for the domestic dialling format. For a more detaileddescription on “Domestic Tone Reporting”, refer to page 48.

    To Change Domestic Phone Numbers

    1. Enter your followed by 2 and the button. Three beeps will be heard and the STAY and AWAY indicators will begin to flash. If there are phone numbers already programmed, they will be displayed one digit at a

    time via the zone indicators on your codepad. Refer to “Table 12: Indicators ForProgramming Domestic Phone Numbers” for the indicators and their meanings. Twobeeps will be heard after the last digit has been displayed on the zone indicators.

    If there are no previous phone numbers programmed, a further two beeps will be

    heard after entering this mode indicating there are no phone numbers currentlyprogrammed.

    2. Enter the required (Each number will be displayed as it is entered).

    3. After each phone number, press the button before entering the next phonenumber. This separates the end of the first phone number and the beginning of thenext.

    4. After the last phone number has been entered, press the button.

    + 2 + + + + +

    Indicators For Phone Numbers

    Digit Zone 1Light

    Zone 2Light

    Zone 3Light

    Zone 4Light

    Zone 5Light

    Zone 6Light

    Zone 7Light

    Zone 8Light

    MainsLight

    1 ü 2 ü 3 ü 4 ü 5 ü 6 ü 7 ü 8 ü 9 ü ü 0 ü

    Table 12: Indicators For Programming Domestic Phone Numbers

    Solution-16 Operators Manual 31

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • 3 Event Memory RecallThis feature allows you to playback the last forty events that have occurred to the system.If the system has been partitioned, only 10 events will be displayed for each area.

    The “Event Memory Recall” mode reports all alarms and arming or disarming of the systemin the STAY or AWAY modes. This function helps with trouble shooting of the system. Theevents are displayed via the zone indicators on your codepad.

    To Enter The Event Memory Recall Mode

    1. Enter your followed by 3 and the button.Three beeps will be heard.

    The events will be played back via the zone indicators on the codepad in reversechronological order.

    + 3 + Example

    If the events were as follows:

    Event No Event Type1 System Armed2 Alarm Zone 33 Alarm Zone 44 System Disarmed

    Table 13: Example Events

    The event memory playback will report as follows:

    Event No Event Type Indicator4 System Disarmed All Indicators Off Except Mains Indicator3 Zone 4 Alarm Zone 4 Indicator Illuminates2 Zone 3 Alarm Zone 3 Indicator Illuminates1 Zone Armed in AWAY Mode AWAY Indicator Illuminates

    Table 14: Example Event Playback

    Each event is indicated by a beep and an illuminated indicator. Resetting a 24 hour alarm inthe disarmed state is indicated by one beep only.

    After the last event, two beeps will be heard to indicate the end of playback. The replay can

    be terminated at any time by pressing the button. This termination will be indicatedby two beeps.

    32 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • 4 Walk Test ModeWalk Test Mode allows you to test your detection devices to ensure that they arefunctioning correctly. You should perform this test on a weekly basis to test the system.

    Before entering Walk Test Mode, isolate any zones that are not required for testing. Referto “Isolating Zones” on page 21.

    Entering Walk Test Mode

    1. Enter your followed by 4 and the button. Three beeps will be heard and the STAY and AWAY indicators will begin to flash. The

    codepad will beep once every second while the system is in the Walk Test Mode. 2. Unseal and seal the zones to be tested. The codepad will sound a long beep while the horn speaker will sound a short beep

    every time a zone is unsealed or sealed.

    3. Press the button when finished.Two beeps will be heard and the STAY and AWAY indicators will extinguish.

    + 4 +

    Solution-16 Operators Manual 33

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • 5 Turning Outputs On and OffYour control panel can have a maximum of up to five outputs programmed to operatevarious devices. These devices could be an air conditioner, security lighting or electricgates etc. They can be turned on and off using your Master Code.

    To Turn An Output ‘ON’ From The Codepad

    1. Enter your followed by 5 and the button. Three beeps will be heard and the STAY and AWAY indicators will begin to flash.

    2. Enter the followed by the button. Three beeps will be heard.

    3. Press when finished.

    Two beeps will be heard and the STAY and AWAY indicators will extinguish.

    + 5 + + + +

    To Turn An Output ‘OFF’ From The Codepad

    1. Enter your followed by 5 and the button. Three beeps will be heard and the STAY and AWAY indicators will begin to flash.

    2. Enter the followed by the button. Two beeps will be heard.

    3. Press when finished.

    Two beeps will be heard and the STAY and AWAY indicators will extinguish.

    + 5 + + + +

    34 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • 6 Setting The Date and TimeThis date and time needs to be set whenever the panel loses all power or when daylightsavings is introduced.

    To Enter A New Date and Time

    1. Enter your followed by 6 and the button. Three beeps will be heard and the STAY and AWAY indicators will begin to flash. 2. Enter the date, month, year, hour and minute using the (DD, MM, YY, HH, MM)

    format.

    3. Now press the button.Two beeps will be heard and the STAY and AWAY indicators will extinguish.

    + 6 +

    Example

    To enter the date for the 1st January 1996 at 10:00 PM, the following should be entered;

    + 6 + + 0 + 1 + 0 + 1 + 9 + 6 + 2 + 2 + 0 + 0 +

    7 Reserved

    Solution-16 Operators Manual 35

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • 8 Setting STAY Mode 2 ZonesThis function allows you to select which zones you want automatically isolated when the

    system is armed in STAY mode 2 by holding the 0 button down. Refer to “Hold DownFunctions” on page 38 for further information.

    To Set STAY Mode 2 Zones

    1. Enter your followed by 8 and the button.2. Three beeps will be heard and the STAY indicator will begin to flash.

    3. Enter the that you want isolated followed by the button. The zone indicator will begin to flash. 4. Enter a second or more zone numbers that you wish to isolate remembering to press

    the button after each zone selected to be isolated.

    5. Press the button when finished.Two beeps will be heard and the STAY indicator will extinguish.

    + 8 + + + + + +

    9 Reserved

    36 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • User Code Functions - Partitioned Systems Only

    + +

    Function Description0 Arming and Disarming All Areas At The Same Time

    Table 15: User Code Functions

    0 Arming and Disarming All AreasThis option allows you to arm or disarm all areas at the same time that you belong to. Allareas will arm or disarm to follow the state of the area that the code was entered from (ie. Ifyou disarm an area, all other areas will disarm, or, if you arm an area, all other areas willarm as well).

    This allows the user to ensure that all areas will be armed by pressing one extra buttonrather than entering the user code at each area codepad.

    To Arm Or Disarm All Areas At The Same Time

    1. Enter your followed by 0 and the button.Two beeps will be heard.

    + 0 +

    Solution-16 Operators Manual 37

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Hold Down FunctionsHold down functions have been incorporated to allow easy activation of specific operations.When a button is held down for two seconds, two beeps will be heard and a particular functionwill operate. These functions are listed below.

    # Arm The System In AWAY ModeHolding the button down until two beeps are heard will arm the system in the

    AWAY mode. If the system has been partitioned, holding the button down on an“Area Addressable” codepad will arm the area that the codepad belongs to. Thisfunction is not available on the “Master Partitioned” codepad.

    * Arm The System In STAY Mode 1Holding the button down until two beeps are heard will arm the system in STAY

    mode 1. If the system has been partitioned, holding the button down on an“Area Addressable” codepad will arm the area that the codepad belongs to in STAY mode1.

    If there has not been an alarm during the armed cycle, holding the button downagain will disarm the system. This function is not available on a “Master Partitioned”codepad.

    0 Arm The System In STAY Mode 2Holding the 0 button down until two beeps are heard will arm the system in STAYmode 2. If there has not been an alarm during the armed cycle, holding the 0 buttondown until another two beeps are heard will disarm the system.

    1 Horn Speaker TestHolding the 1 button down until two beeps are heard will sound the horn speaker for atwo second burst. No other sounding device will sound in this mode.

    2 Bell TestHolding the 2 button down until two beeps are heard will sound the internal sirens for atwo second burst. No other sounding device will sound in this mode. If a satellite sirenhas been connected to the control panel, this function will also test the horn speaker for atwo second burst followed by the strobe connected to the satellite siren.

    38 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • 3 Strobe TestHolding the 3 button down will operate the strobe. No other device will operate in thismode. If a satellite siren has been connected to the control panel, this function will alsotest the strobe on the satellite siren.

    To Turn Strobe Test ‘On’

    1. Hold the 3 button down until three beeps are heard.The strobe will begin to flash.

    To Turn Strobe Test ‘Off’

    1. Hold the 3 button down until two beeps are heard.The strobe will stop flashing.

    4 Turning Day Alarm On and OffHolding the 4 button down for two seconds will turn day alarm on or off.

    To Turn Day Alarm ‘On’

    1. Hold down the 4 button until three beeps are heard.Day alarm is now turned on.

    To Turn Day Alarm ‘Off’

    1. Hold down the 4 button until two beeps are heard.Day alarm is now turned off.

    5 Fault Analysis ModeThere are various system faults that can be detected by control panel. When any of theseare present, the FAULT indicator will begin to flash and the codepad will beep once everyminute.

    To determine the type of fault, hold the 5 button down until two beeps are heard. TheSTAY and AWAY indicators will begin to flash in unison with the FAULT indicator. One ormore of the zone indicators (1-8) will also illuminate indicating the type of fault. Referto “Fault Descriptions” on page 41 for more information.

    To clear “Fault Analysis” mode, press the button once and two beeps will beheard.

    Zone Indicator Description1 Low Battery2 Date and Time3 Sensor Watch4 Horn Speaker Disconnected5 Telephone Line Fault6 E2 Fault7 Zone 16 In Alarm - Partitioned Systems Only8 Communications Failure

    Table 16: Fault Indicators

    Solution-16 Operators Manual 39

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • 6 Initiate A Modem Call

    Holding the 6 button down until two beeps are heard will force the panel to call atelephone number in an attempt to connect to your installers remote computer. Yourinstaller may require you to do this for remote programming changes.

    7 Reset Latching Outputs

    Holding the 7 button down until two beeps are heard will reset any device that has beenprogrammed to remain on once it has been activated. This could be a door bell that isrequired to keep ringing until someone has acknowledged it.

    8 Codepad ID and Beeper Tone Change

    Holding the 8 button down for two seconds performs two functions.

    The first function is to indicate which area the codepad belongs to when the system hasbeen partitioned.

    The second function changes the tone of the buzzer in your codepad. There are fiftydifferent tones to choose from and they are specific to each codepad. In a multiplecodepad installation each codepad can have a different tone.

    Function 1 - Determining The Area Number.

    1. Hold the 8 button down until two beeps are heard.2. Release the 8 button3. A zone indicator will illuminate

    Z1 = Area One CodepadZ2 = Area Two CodepadZ3 = Area Three CodepadZ4 = Area Four CodepadZ7 = Master Partitioned CodepadIf no zone indicator illuminates the codepad cannot be used in partitioning.

    4. Press the button when finished

    Function 2 - Changing The Tone Of The Buzzer.

    1. To change the tone of the codepad buzzer, hold the 8 button down continuously. The tone of the buzzer will start to increase in pitch. If the codepad is an “Area Addressable” codepad or a “Master Partitioned”

    codepad, two beeps will be heard indicating the area of the codepad asdescribed above. Shortly after hearing the two beeps, the tone of the buzzerwill start to increase in pitch.

    2. Release the 8 button when the desired tone is reached.

    40 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • 9 Initiate A Test ReportHolding the 9 button down until two beeps are heard will send a test report. This isused to test the dialling and reporting capabilities of you system without causing thesirens to sound. This feature is only applicable if your system has a communicationsdialler fitted and enabled. Refer to “Installation Notes” on page 62 .

    Fault DescriptionsWhenever a system fault occurs, the FAULT indicator will flash and the codepad will beep onceevery minute. As these system faults can effect the operation of your system, you should contactyour installer as soon as possible.

    If the MAINS indicator is flashing, this is because the AC mains has been disconnected. There is

    no need to hold the 5 button down to determine this type of fault.

    To Determine The Type Of Fault

    To determine the type of fault that has occurred, hold down the 5 button until two beeps areheard.

    The STAY and AWAY indicators will begin to flash in unison with the FAULT indicator. One ormore of the zone indicators (1-8) will also illuminate indicating the type of fault. Refer to“System Faults” on page 42 for more information.

    To Acknowledge The Fault

    To acknowledge the fault, press the button. The STAY and AWAY indicators willextinguish and the FAULT indicator will stop flashing and remain illuminated. The codepad willcease its once a minute beep.

    If an AC mains failure has been acknowledged, the codepad will cease its once a minute beep,however, the MAINS indicator will remain flashing until the AC mains is connected again.

    Warning ! Contact your installer for any reported fault.

    Solution-16 Operators Manual 41

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • System Faults

    1 Low BatteryA low battery fault will register when the systems battery voltage is not capable ofsupplying back-up power to the system if the AC mains power fails. The battery voltage iscontinually being monitored.

    2 Date and TimeA date and time fault will register every time the system is powered up or if the systemautomatically resets itself due to an internal fault. Refer to “Master Code Functions” onpage 28 for further information on setting the date and time.

    3 Sensor WatchA sensor watch fault will register because one of the detection devices has stopped

    working. Hold down the 5 button for another two seconds to show what zone hastriggered the sensor watch fault.

    4 Horn Speaker DisconnectedA horn speaker fault will register if the horn speaker becomes disconnected from the maincontrol panel.

    5 Telephone Line FaultA line fault will register if the telephone line has been disconnected from the panel for morethan 40 seconds. This can only occur if the line fault module has been fitted to your system.

    6 E2 FaultAn E2 fault will register when control panel detects an internal checksum error.

    7 Zone 16 In Alarm - Partitioned Systems OnlyThis fault will register when zone 16 has triggered into alarm condition if the system hasbeen partitioned. If you are using a “Master Partitioned” codepad, the AUX indicator will beilluminated. You may need to contact your installer regarding this fault.

    8 Communications FailureA communications fault will register if your system was unsuccessful in calling the receivingparty. The receiving party could be your monitoring station, your pager or any othertelephone. This is only applicable if you have a communications dialler fitted.

    AC Mains Failure

    If the AC mains is disconnected for two minutes the MAINS indicator will flash and the

    codepad will beep once every minute. To stop the beeps, press the button. If themains power returns, the indicator will stop flashing.

    There is no need to hold down the 5 button to determine this type of fault.

    42 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • PartitioningYour control panel can be partitioned or split into four individual areas. All four areas can beoperated from one “Master Partitioned” codepad or from four separate “Area Addressable”codepads. One of each is designated to a particular area.

    Master Partitioned Codepad IndicatorsThe indicators on a “Master Partitioned” codepad are configured in four groups. Refer to “Figure2: Master Partitioned Codepad” on page 44. Following is a description of what the indicatorsshow.

    1 Zone IndicatorsIndicators (1-8) show the status of each zone. These zones belong to the area that has the“AREA DISPLAY” indicator illuminated (ie. If a zone indicator is illuminated, then the zone isunsealed and if the zone indicator is not illuminated, then the zone is sealed).

    2 Area ON/OFF Indicators

    The group of four “AREA ON/OFF” indicators show the status of each area (ie. If anindicator is illuminated, that area is armed and if the indicator is not illuminated, that area isdisarmed).

    3 Area Display IndicatorsA group of four “AREA DISPLAY” indicators that show what area the zones belong to thatare currently being displayed.

    4 Status IndicatorsA group of four indicators show the following:

    Aux IndicatorThis indicator displays when the control panel is using the telephone line communicating tothe receiving party.

    Mains Indicator

    This indicator displays the status of the AC mains power (ie. If the indicator is illuminatedthe AC mains power is normal and if the indicator is flashing the AC mains power isdisconnected).

    Fault Indicator

    This indicator displays the status of the systems fault register (ie. If the indicator is flashingthe system has detected a fault which has not yet been acknowledged. If the indicator isilluminated the fault has been acknowledged and if the indicator is not illuminated thesystem has no faults).

    Partial Indicator

    Whether an area is armed in STAY mode (ie. If the PARTIAL indicator is illuminated, an areais armed in STAY mode and if the PARTIAL indicator is not illuminated no areas are armed inSTAY mode).

    Solution-16 Operators Manual 43

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Operation Of Codepads In Partitioning

    Operating From Area “Addressable” CodepadsIf you have a partitioned system with “Area Addressable” codepads, the operating procedure isexactly the same as described throughout this manual. Refer to “Hold Down Functions” on page38 to determine what area a particular codepad belongs to.

    Operating From A “Master Partitioned” CodepadIf you have a partitioned system with a “Master Partitioned” codepad installed, the operatingprocedure is the same as described throughout this manual with one exception. All operations arerelative to the area whose “AREA DISPLAY” indicator is illuminated at the time.

    Example

    If the “AREA DISPLAY” indicator number 4 is illuminated, all operations performed will effectArea 4 only. To perform any operations in another area, you will have to move the “AREADISPLAY” illuminator to the desired area.

    To Move From One Area To The Next

    1. Press the button. The area display indicator will move to the next area.

    2. Press the button again.The area display indicator will move to the next area.

    Figure 2: Master Partitioned Codepad

    44 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • Communication OptionsIntroductionYour Solution-16 control panel (CC880) has a communications dialler fitted to report allalarms and system events. These events can be reported to a number of destinations via differenttransmission formats. These different formats have varying levels of ability. Some can report allevents while others have limitations and may report alarms only. The suitability of the differentformats should be discussed with your installer.

    Options and AccessoriesDomestic Tone Only ReportingDomestic Voice Message ReportingBack To Base Reporting Via Digital CommunicatorBack To Base Reporting Via SecuritelBasic Pager ReportingAlpha Pager ReportingDTMF Command ModuleVoice ModulePhone Controller

    Solution-16 Operators Manual 45

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Remote FunctionsRemote Arming Using The Phone ControllerIntroductionThis feature allows you to arm your system from any remote location via a telephone line. Forobvious security reasons the system cannot be disarmed using this method. To make use of thisfeature you will require a telephone and the phone controller.

    Operation

    To Remotely Arm Your System

    1. Call the telephone number that your system is connected to. 2. When the control panel has answered the call, a short jingle will be heard. Wait for a short

    pause in the tones and then hold the phone controller to the mouth piece of the telephoneand press the button on the side of the unit for 3 seconds to arm the system.

    Two beeps will be heard to indicate that the tone generated has armed your system. 3. Hang up the telephone and the system will remain armed.

    If you hear a number of strange sounding tones when your control panel answers the call, thismeans that your system has been set for remote programming functions. Simply wait for a pausein the tones and follow the above steps to remotely arm your system.

    If the control panel does not answer the call, this means that the system may already be armed orremote functions have not been enabled. Refer to the “Installations Notes” to check if “Arm OnlyVia The Telephone” on page 65 has been enabled.

    Note: Where both remote arming and remote programming have been selected, the controlpanel will answer the call expecting the remote programming computer. This is easilynoticed as the modem negotiating tones will be heard rather than the remote armingjingle.

    46 Solution-16 Operators Manual

    ISSUE140.DOC Electronics Design & Manufacturing Pty Limited

  • Operating The System Using A Touch Tone TelephoneIntroductionThe DTMF Command Module will allow you to operate your control panel remotely via thetelephone line. Once a communications link has been established with your alarm system, you willbe able to perform any system functions using the codepad on a touch tone telephone for bothMaster Code and User Code functions.

    The DTMF command module also allows domestic dialling to be acknowledged by pressing the

    # key on the telephone codepad. The DTMF command module needs be fitted to your systemand programmed accordingly by your installer.

    Operation

    To Establish A Communication Link With Your Alarm System (Non Partitioned System)

    1. Dial the telephone number that the panel is connected to. When the panel answers your call,you will hear a short jingle.

    2. After the jingle, press the 0 button on your telephone during a pause. You will then hear asecond jingle. You have now established a link.

    Note: If you have a partitioned system, pressing a 00 to establish a link will not work.

    To Establish A Communication Link With Your Alarm System (Partitioned System)

    1. Dial the telephone number that the panel is connected to. When the panel answers your call,you will hear a short jingle.

    2. To establish a link, you will need to enter 1, 2, 3 or 4 corresponding to the areanumber you wish to establish a link with.

    Once you establish a link to the partitioned panel, you cannot toggle from area to area like you

    can on a Master Partitioned codepad by pressing the # button on the telephone. To accessanother area, you will need to terminate the link, redial the panel and then choose the requiredarea.

    You can ARM and DISARM all areas at the same time when linked to a partitioned systemprovided that the user code is valid for all areas.

    When connected to the panel, any normal system function can be performed by simply enteringthe numbers on the telephone as you would from a codepad. (HOLD DOWN functions howeverwill not work). Please refer to the “Master Code Functions” on page 28 for a description of eachof the available functions. Audible indications are also described in this section.

    While you are connected, if a button is not pressed within a sixty second period, you will hear thejingle of decreasing pitch which will indicate that the link has been terminated.

    To Terminate The Link With Your Alarm System1. Press the # button on the telephone twice to terminate the link. You will hear a short

    jingle of decreasing pitch to indicate termination of the link.

    Solution-16 Operators Manual 47

    Electronics Design & Manufacturing Pty Limited ISSUE140.DOC

  • Domestic Tone Reporting

    Operation Of Domestic Tone ReportingWhen an alarm occurs, your system will commence dialling the first programmed phone number.If a busy or engaged tone is detected, the control panel will hang up and commence dialling thesecond phone number, if one is programmed. The first call will however be counted as oneunsuccessful dialling attempt. The calling procedure can be aborted at any time by entering yourcode.

    Note: A maximum of 6 calls per alarm event will be made. This count includes anyunsuccessful calls. The call count will be reset if the zone re-triggers and a further 6attempts will be made. The control panel will stop dialling after it has received anacknowledge tone or after it has made 6 attempts or 3 successful calls.

    If busy tone is not detected, the control panel will assume that the phone has been answered andwill begin sending its message.

    The message consists of a siren tone followed by system