18
Solid State Detectors for Upgraded PHENIX Detector at RHIC

Solid State Detectors for Upgraded PHENIX Detector at RHIC

Embed Size (px)

DESCRIPTION

Solid State Detectors for Upgraded PHENIX Detector at RHIC. Bits of history. 2003 - Maturity and planning for the next 10-15 years Precision measurements, extended coverage. FCAL. 1991 – Project Inception 1997 – First ion collisions in RHIC 2002 – statements of major discovery. SMD/. FCAL. - PowerPoint PPT Presentation

Citation preview

Page 1: Solid State Detectors for Upgraded PHENIX Detector at RHIC

Solid State Detectors for Upgraded PHENIX Detector at RHIC

Page 2: Solid State Detectors for Upgraded PHENIX Detector at RHIC

1991 – Project Inception1997 – First ion collisions in RHIC2002 – statements of major discovery

Bits of history

SMD/

FCALFCAL

2003 - Maturity and planning for the next

10-15 years

Precision measurements,

extended coverage

Page 3: Solid State Detectors for Upgraded PHENIX Detector at RHIC

PHENIX Upgrade

Page 4: Solid State Detectors for Upgraded PHENIX Detector at RHIC

Solid State Upgrade components

• Central Barrel Silicon Tracker – Two layers of pixels (ALICE);– Two layers of StriPixels;

• Forward Silicon Trackers (South and North)• Four layers of silicon discs (short strips with pixel-type

readout) each;

• Forward W-Si Calorimeters (South and North)• 22 layers of 6x6 cm2 pad sensors (15x15 mm2 pads);• One layer of StriPixel Detectors (0.5 x 60 mm2 strips)

Page 5: Solid State Detectors for Upgraded PHENIX Detector at RHIC

• Specifications– 4 layers with large acceptance ( & < 1.2)– Displaced vertex measurement : < 40 m– Charged particle tracking : p/p ~ 5% p at high pT

– Working detector for both of heavy ion and pp collisions

• Technology Choice– Hybrid pixel detectors in 2 inner layers– Stripixel sensors w/ SVX4 readout chip in 2 outer

layers

Barrel VTX Detector

Pixel layersr=5.0 cm, Δz~±10 cmr=2.5 cm, Δz~±10 cm

Strip layersr=10.0 cm, Δz~±16 cmr=14.0 cm, Δz~±19 cm

Beam pipe

Page 6: Solid State Detectors for Upgraded PHENIX Detector at RHIC

Barrel: Pixel Detectors

• Technology choice: – ALICE1LHCb read-out chip

32 x 256 ch / chip– 4 chips bump bonded to sensor

with pixel size: 50 x 450 – Grouped to ladders– Readout through pilot module

• R&D with ALICE and NA60– Adapt technology to PHENIX – Detectors operated in NA60

Readout Bus

Sensor

Readout chipSupport/cooling

Half ladder

Pixel detector

NA60 In-In collision taken 2003

Analog PILOT(control, etc)

digital PILOT(read pixel data)

Optical link driver chip

(GOL)

Optical package

dataclock & control

Read out BusFrom pixel Optical I/O

PILOT module

Page 7: Solid State Detectors for Upgraded PHENIX Detector at RHIC

Barrel: Strip Detector• Strip sensor

– BNL’s new “stripixel” concept : single-sided sensor w/ 2-D position sensitivity

– Charge sharing by 2 spirals in one pixel (80 μm ×1000 μm)& projective x/u-strip readout

– Pre-production sensor (Hamamatsu)

• p+/n/n+ structure• 3.5×6.4 cm2

• 625/500 μm thickness• Spiral : 5/3μm line/gap• Pixels :

384×30×2=23,040• Strips : 384×2×2=1,536

– Probing tests are on-going for evaluation

Z. Li, NIMA518, 738 (2004)

x3’ u1’ u2’

x2’ x1’ u1’u2 u3 x3

u1 x1 x2

0.00E+00

1.00E-12

2.00E-12

3.00E-12

4.00E-12

5.00E-12

6.00E-12

7.00E-12

8.00E-12

9.00E-12

1.00E-11

0 50 100 150 200 250 300 350 400

V_bias [V]

C [

F]

0.00E+00

5.00E-10

1.00E-09

1.50E-09

2.00E-09

2.50E-09

3.00E-09

3.50E-09

0 50 100 150 200 250 300 350 400

V_bias [V]

I [A

]CVIV

Page 8: Solid State Detectors for Upgraded PHENIX Detector at RHIC

End Caps: Wedge shaped strip detectors

Page 9: Solid State Detectors for Upgraded PHENIX Detector at RHIC

Backplane

-V

R Amplifier

GND

C

W-Si Forward Calorimeters

Page 10: Solid State Detectors for Upgraded PHENIX Detector at RHIC

Calorimeters: numerology

0 identifier (shower max detector)

Sensors 168 6x6 cm2, 600, single sided, single layer, 2-d readout (stripixels)

Pitch 0.5 mm

Readout channels 43000

SVX4 336

Electromagnetic (fine) section

Sampling structure 5mm x 16 2.5 mm W + 0.3 mm Si + PCB + protection and air gap

Sensors 2688 6x6 cm2, 300 Si, 15x15 mm2 readout pads, 168 sensors per layer

Readout channels 5376 6 or 10 pads are ganged per readout channel

Hadronic (coarse) section

Sampling structure 18 mm x 6 15.5 mm W + 0.3 mm Si + PCB + protection and air gap

Sensors 1176 196 per layer

Readout channels 3136 6 pads are ganged per readout channel

Page 11: Solid State Detectors for Upgraded PHENIX Detector at RHIC

Calorimeters: Sampling cell design

Backplane

-V

R Amplifier

GND

C

Detector ladder glued to the W plate

To avoid To avoid draining bulk current into electronics;draining bulk current into electronics;loss of electronics whenever channel trips;loss of electronics whenever channel trips;

and to save spaceand to save space

Thin film technology used to implement rc-chip on interconnect board

Absorber (W)

Sensors carrier board

Page 12: Solid State Detectors for Upgraded PHENIX Detector at RHIC

AC Coupled Si Detector

SiO2

p+n+

Al

AlSiO2+Si3

N4

Polysilicon bias resistors

bias strip

Calorimeters: solution to decoupling

30% extra cost

$160 -> $240 for 6x6 cm2 detector

Page 13: Solid State Detectors for Upgraded PHENIX Detector at RHIC

Prototype Silicon Wafers For Calorimeter

62 mm

62 m

m

Si Wafer :4x4 pads of detection

(15x15 mm2)

4” High resistive wafer : 4” High resistive wafer : 5 K5 Kcmcm

Thickness : 300 microns Thickness : 300 microns 3 % 3 %

Tile side : Tile side : 62.0 + 0.062.0 + 0.0

- 0.1 mm- 0.1 mm

Guard ringGuard ring

In Silicone ~80 e-h pairs / micron In Silicone ~80 e-h pairs / micron 24000 e24000 e-- /MiP/MiP

Capacitance : ~80 pFCapacitance : ~80 pF

Leakage current : 5 – 15 nALeakage current : 5 – 15 nA

Full depletion bias : ~100 VFull depletion bias : ~100 V

Nominal operating bias : 150 VNominal operating bias : 150 V

ELMA:Well established technology;Long production historyGood reputation

Page 14: Solid State Detectors for Upgraded PHENIX Detector at RHIC

Calorimeters: 0 identifier

RC

RCSVX4

SVX4

Test structure mask

X

Y500

Page 15: Solid State Detectors for Upgraded PHENIX Detector at RHIC

Upgrade Schedule Scenario

2002 2003 2004 2005 2006 2007 2008 2009 2010 2011

Aerogel

TOF-W

HBD

VTX-barrel

VTX-endcap

NCC

MuTrigger

DAQ

R&D Phase Construction Phase Ready for Data

Page 16: Solid State Detectors for Upgraded PHENIX Detector at RHIC

BACKUPS

Page 17: Solid State Detectors for Upgraded PHENIX Detector at RHIC

Stripixel Sensor : Principle• A novel “stripixel” detector concept innovated by BNL

Instr. Div. : Z. Li, NIMA518, 738 (2004).– Single-sided sensor

– 2-dimentional position sensitivity by charge sharing

– Two independent electrodes interleaved in one pixel are projectively read out by strips.

• Advantages (compared with a double-sided strip sensor)– Simple structure : reduce costs and integration issues

– Radiation hard (cf. a complicated n+ side structure in a double-sided strip sensor)

• Disadvantages– Large capacitance/strip due to the interleaving scheme

– Decrease in S/N due to charge sharing

Page 18: Solid State Detectors for Upgraded PHENIX Detector at RHIC

1000 m

80 m

U-pixel(1stmetal)

X-pixel(1stmetal)

2nd MetalX-strip

2nd MetalU-strip

FWHMfor chargediffusion

BondingPad forX-strip

Go toBondingPad forU-strip

Z. Li, Inst. Div., BNL

Silicon Strips Detectors for Central Tracker

• Sensor technology choice:– Single sided, two dimensional read-out

sensor developed by Z. Li of BNL Inst. Division

– 80 x 3 cm strip– X/U stereo read-out– 384 x 2 x 2 per sensor chip (64.6 mm x

30.7 mm)

• Readout chip technology choice:– SVX4 chip developed by FNAL/LBNL – 128 ch/chip– 50 pitch read-out

• Ongoing R&D– Sensor prototype tests – Tests of SVX4 readout with sensor

Sensor structure

SVX4 chip

Design of the test hybrid moduleWith SVX4 readout chip