56 CURRENT MONITORING 800.354.8556 503.598.4564 www.veris.com ©2006Veris Industries Loop powered analog current sensor simplifes installation Power the sensor and receive the signal with only two wires...lower cabling & commissioning costs than with traditional 3-wire sensors Self-gripping split-core for fast retrofit installation... no need to remove conductor (H921) Economical solid-core features adjustable bracket for easy alignment Selectable factory calibrated ranges up to 200A for increased flexibility and resolution Factory calibrated switch selectable ranges for high resolution and installation ease Three field-selectable ranges per unit... fewer versions to choose from, stock, and install Mounting bracket for installation flexibility 5-year limited warranty The Hawkeye 721LC, 721HC, & 921 provide accurate load trending information with a proportional 4-20mA output signal. Preset slide-switches provide easy field setup of sensed amperage range without clumsy jumpers. APPLICATIONS Load trending Motor control Solid- & Split-Core 4-20mA Output Loop Powered Current Transducers 721LC/721HC/921 H721HC (LC) LINEAR OUTPUT Scale software as shown H921 LINEAR OUTPUT Scale software as shown SENSED AMPS 30/60/120A* 4mA 0A 20mA SENSOR OUTPUT *Factory calibrated ranges selected with the amperage range switch SENSOR OUTPUT 20mA 4mA 0A 50/100/200A* (10/20/40A) SENSED AMPS *Factory calibrated ranges selected with the amperage range switch H721LC H921 Slide Switch Scaling for Easy Setup ��ORDERING INFORMATION MODEL AMPERAGE RANGE OUTPUT TYPE H721LC Solid-Core 0-10/20/40A 4-20mA, loop powered H721HC Solid-Core 0-50/100/200A 4-20mA, loop powered H921 Split-Core 0-30/60/120A 4-20mA, loop powered Easy 2-wire Installation Maximize Reliability Minimize Installed Cost ACCESSORIES Universal Power Supply, Universal Mounting Bracket Kit...See page 234

Solid- & Split-Core 4-20mA Output Loop Poweredlit.stromquist.com/docs/VERISALTALABS/h721-921_d.pdfThe Hawkeye 721LC, 721HC, & 921 provide accurate load trending information with a

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • 56

    CURRENT MONITORING

    800.354.8556 503.598.4564 www.veris.com ©2006Veris Industries800.354.8556 503.598.4564 www.veris.com ©2006Veris Industries

    Loop powered analog current sensor simplifes installation

    ■ Power the sensor and receive the signal with only two wires...lower cabling & commissioning costs than with traditional 3-wire sensors

    ■ Self-gripping split-core for fast retrofit installation... no need to remove conductor (H921)

    ■ Economical solid-core features adjustable bracket for easy alignment

    Selectable factory calibrated ranges up to 200A for increased flexibility and resolution

    ■ Factory calibrated switch selectable ranges for high resolution and installation ease

    ■ Three field-selectable ranges per unit... fewer versions to choose from, stock, and install

    ■ Mounting bracket for installation flexibility

    ■ 5-year limited warranty

    The Hawkeye 721LC, 721HC, & 921 provide accurate load trending information with a proportional 4-20mA output signal. Preset slide-switches provide easy field setup of sensed amperage range without clumsy jumpers.

    APPLICATIONS

    ■ Load trending

    ■ Motor control

    Solid- & Split-Core 4-20mA Output Loop Powered Current Transducers

    721LC/721HC/921

    H721HC (LC) LINEAR OUTPUTScale software as shown

    H921 LINEAR OUTPUTScale software as shown

    SENSED AMPS

    30/60/120A*4mA

    0A

    20mA

    SENS

    OROU

    TPUT

    *Factory calibrated ranges selectedwith the amperage range switch

    SENS

    OR O

    UTPU

    T

    20mA

    4mA0A 50/100/200A*

    (10/20/40A)SENSED AMPS

    *Factory calibrated ranges selected with the amperage range switch

    H721LC

    H921

    Slide Switch Scaling forEasy Setup

    ���������������

    ORDERING INFORMATION

    MODEL AMPERAGE RANGE OUTPUT TYPEH721LC Solid-Core 0-10/20/40A 4-20mA, loop powered

    H721HC Solid-Core 0-50/100/200A 4-20mA, loop poweredH921 Split-Core 0-30/60/120A 4-20mA, loop powered

    Easy 2-wireInstallation

    Maximize ReliabilityMinimize Installed Cost

    ACCESSORIESUniversal Power Supply, Universal Mounting Bracket Kit...See page 234

  • 800.354.8556 503.598.4564 www.veris.com ©2006Veris Industries

    CURRENT MONITORING

    57

    800.354.8556 503.598.4564 www.veris.com ©2006Veris Industries

    OptionalDIN RailClip

    2.90"(74 mm)

    2.58"(65 mm)

    3.20"(81 mm)

    2.50"(64 mm)

    1.04"(26 mm)

    1.10"(28 mm)

    Self-gripping Iris

    0.90"(23 mm)

    0.20"(5 mm)

    0.13" Dia.(3.3 mm)

    1.05"(27 mm)

    2.65"(67 mm)

    0.75" Dia(19 mm)

    0.89"(22 mm)

    2.55"(65 mm)

    2.93"(74 mm)

    Adjustable Mounting Bracket

    Removable Mounting Bracket

    DIN Rail ClipSide View

    OptionalDIN RailClip

    DIN Rail ClipSide View

    + +

    3.75”(95 mm)

    SPECIFICATIONSAmperage Range See ordering tableOutput 4-20mADCInsulation Class 600VAC rmsFrequency 60Hz. nominalTemperature Range -15° to 60°CHumidity Range 0 - 95% non-condensingAccuracy ±2%Response Time 2 sec.Supply Voltage 12-30VDC Loop poweredSupply Current 30mA (max.)Dimensions (H721LC & H721HC) 2.93" (74mm) x 2.65" (67mm) x 1.05" (27mm)Sensor Hole Size 0.75" (19mm) DiameterDimensions (H921)…(LxWxH) 2.90" (74mm) x 2.58" (65mm) x 1.04" (26mm)Sensor Opening Size (H921)…(LxW) 1.10" (28mm) x 90" (23mm)

    APPLICATIONS/WIRING EXAMPLE DIMENSIONAL DRAWINGS

    H721LC & H721HC

    H921

    Fan or Pump

    12-30VDCPOWER SOURCE

    +-

    CONTROLLER

    +–

    CONTACTOR

    AI

    Motor

    H721LC/721HC/921