SOLAREDGE Grid‐Tie Inverter (2 Included) SE10000A‐US + SE5000A‐US 1
Nominal rated AC Power Output 15.0 kW
Maximum AC Power Output 16.4 kW
AC Output Line Connection 3 ‐ wire (L1‐L2‐N) plus Ground
AC Output Voltage (L ‐ N) 120 VAC
AC Output Voltage (L ‐ L) 240 VAC
AC Frequency Min ‐ Nom ‐ Max 59.3 ‐ 60.0 ‐ 60.5 Hz
GFDI Threshold 1 Amp
Utility Monitoring, Island Protection, Country configuration Yes
Product Certification UL1741, UL1699B, UL1998, CSA 22.2 (Grid Connection IEEE 1547)
Enclosure NEMA 3R (<25 dBA)
Cooling Natural Convection
Rapid Shut Down ‐ NEC 2014 690.12 Yes
Revenue Grade Data, ANSI C12.1 Optional
Supported Communication Interfaces RS485, RS232, Ethernet, ZigBee (optional)
SOLAR PANELS ‐ YLM 72 Cell YLM‐330D‐32B 48
Total module power output STC 15,840 Watts
Modules (1960mm x 990mm) (25.5kg) per module
Panel (PV) Type Polycrystalline ‐ 72 Cell
Panel (PV) Efficiency 17%
Output Decline 2.5% output decline 1st year + 0.7% per year (2nd ‐ 25th year)
Product Certification UL 1703: CSA / IEC 61701 ED2
Warranty 10 years
P‐400 OPTIMIZERS P‐400 48
Optimizer Operating Range VDC 8.5 ‐ 85.0 VDC
Maximum Individual Optimizer Output Current 15.0 Amps
Maximum Individual Optimizer Output Voltage 80 VDC
Safety Output Voltage 1.0 VDC
Product Certification IEC62109‐1 (class II safety), UL1741
DUAL RACK SYSTEM (1 set included) DUAL RACK Package Included
Dual Rack heavy duty rail 41mm x 80mm x 4267mm Clear finish 24
Dual Rack heavy duty rail caps Clear finish 48
Dual Rack grounding mid‐clamps UL 2703 certified Clear finish 48
Dual Rack end‐clamps Clear finish 24
Dual Rack channel struts for Optimizers Clear finish 48
MC‐4 x 30m connection cable Connects solar panel optimizers to inverter 4
26,425.41$
Price ‐ cdn.
$ 532.03
$ 15.28
$ 14.08
$ 12.01
$ 15.28
$ 8.70
$ 4.49
$ 8.98
$ 8.00
Panels can be priced in black with black racking system. Panels can be priced in 60 cell configuration for smaller roof spacing.
Total Package Cost ‐ Canadian Dollars:
Iiisco grounding lug. Dual Rack standard rail mountable
GBS‐P6 Dual Rack Ground Lug. Compatibale with 12‐6 AWG Copper. Voltage to 1000VDC, 480VAC. UL 467/UL 2703 Certified (price each)
Dual Jack base ‐ 1.0" ED with Lag Bolt and EPDM Bonded Sealing Washer 6005‐T5/6063 T‐5 Aluminum, Silver Anodized
Dual Rack 4"H x 1"OD Alluminum Standoff with Lag Bolt, sealing washers & Hex Bolt
Dual Rack angle brackets, compatible with dual jack 6005 T‐5
Splice bar for Dual Rack standard rail with 4 SS self tapping screws
SolarEdge Zigbee SE‐1000 ZBGW‐K5‐NA Ethernet Gateway Kit with Extended Range Antenna & 1 Slave Module (kit price)
Dual Rack Spun Cone Flashing 9.0" x 12.5" x 0.039" EPCN 1.0" Anodized
OPTIONS
Dual Rack serrated L ‐ foot 84mm x 54mm x 38mm with hex bolt and nut
Residential Grid‐Tie Solar Systems ‐ Designed for Canada
Installation should be done by a qualified installer. NE Generation can recommend an installer for your area
Notes: Specifications are based on normal operating conditions. All NE Generation units are designed for Canadian Climate
INVE
RTER
S
www.solaredge.us
SolarEdge Single Phase Inverters For North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US
USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL
12-25
The best choice for SolarEdge enabled systems IntegratedarcfaultprotectionforNEC2011690.11compliance RapidshutdownforNEC2014690.12 Superiorefficiency(98%) Small,lightweightandeasytoinstallonprovidedbracket Built-inmodule-levelmonitoring InternetconnectionthroughEthernetorWireless Outdoorandindoorinstallation Fixedvoltageinverter,DC/ACconversiononly Pre-assembledSafetySwitchforfasterinstallation Optional–revenuegradedata,ANSIC12.1
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein
are trademarks of their respective owners. Date: 01/2016. V.02. Subject to change without notice.
Single Phase Inverters for North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US
SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US SE10000A- US SE11400A-US OUTPUT
NominalACPowerOutput 3000 3800 5000 6000 7600 9980@208V10000@240V 11400 VA
Max.ACPowerOutput 3300 4150 5400@208V5450@240V 6000 8350 10800@208V
10950@240V 12000 VA
ACOutputVoltageMin.-Nom.-Max.(1) 183-208-229Vac - - 3 - - 3 -
ACOutputVoltageMin.-Nom.-Max.(1) 211-240-264Vac 3 3 3 3 3 3 3
ACFrequencyMin.-Nom.-Max.(1) 59.3-60-60.5 Hz
Max.ContinuousOutputCurrent 12.5 16 24@208V 21@240V 25 32 48@208V
42@240V 47.5 A
GFDIThreshold 1 AUtilityMonitoring,IslandingProtection,CountryConfigurableThresholdsYes YesINPUT MaximumDCPower (STC) 4050 5100 6750 8100 10250 13500 15350 WTransformer-less,Ungrounded Yes Max.InputVoltage 500 VdcNom.DCInputVoltage 325@208V/350@240V Vdc
Max.InputCurrent(2) 9.5 13 16.5@208V 15.5@240V 18 23 33@208V
30.5@240V 34.5 Adc
Max.InputShortCircuitCurrent 45 AdcReverse-PolarityProtection Yes Ground-FaultIsolationDetection 600k Sensitivity MaximumInverterEfficiency 97.7 98.2 98.3 98.3 98 98 98 %
CECWeightedEfficiency 97.5 98 97@208V98@240V 97.5 97.5 97@208V
97.5@240V 97.5 %
NighttimePowerConsumption <2.5 <4 WADDITIONAL FEATURESSupportedCommunicationInterfaces RS485,RS232,Ethernet,ZigBee(optional)RevenueGradeData,ANSIC12.1 Optional(3)
RapidShutdown–NEC2014690.12 YesSTANDARD COMPLIANCESafety UL1741,UL1699B,UL1998,CSA22.2 GridConnectionStandards IEEE1547 Emissions FCCpart15classB INSTALLATION SPECIFICATIONS ACoutputconduitsize/AWGrange 3/4”minimum/16-6AWG 3/4”minimum/8-3AWG DCinputconduitsize/#ofstrings/AWGrange 3/4”minimum/1-2strings/16-6AWG 3/4”minimum/1-3strings/
14-6AWGDimensionswithSafetySwitch(HxWxD) 30.5x12.5x7.2/775x315x184 30.5x12.5x10.5/
775x315x260in/mm
WeightwithSafetySwitch 51.2/23.2 54.7/24.7 88.4/40.1 lb/kg
Cooling NaturalConvection
Naturalconvectionandinternalfan(user
replaceable)
Fans(userreplaceable)
Noise <25 <50 dBAMin.-Max.OperatingTemperatureRange -13to+140/-25to+60(-40to+60versionavailable(4)) ˚F/˚C
ProtectionRating NEMA3R(1)ForotherregionalsettingspleasecontactSolarEdgesupport.(2)Ahighercurrentsourcemaybeused;theinverterwilllimititsinputcurrenttothevaluesstated.(3)RevenuegradeinverterP/N:SExxxxA-US000NNR2(for7600Winverter:SE7600A-US002NNR2).(4)-40versionP/N:SExxxxA-US000NNU4(for7600Winverter:SE7600A-US002NNU4).
POW
ER O
PTIM
IZER
www.solaredge.us
SolarEdge Power OptimizerModule Add-On For North AmericaP300 / P320 / P400 / P405
Up to 25% more energy Superiorefficiency(99.5%) Mitigatesalltypesofmodulemismatchlosses,frommanufacturingtolerancetopartialshading Flexiblesystemdesignformaximumspaceutilization Fastinstallationwithasinglebolt Nextgenerationmaintenancewithmodule-levelmonitoring Module-levelvoltageshutdownforinstallerandfirefightersafety
PV power optimization at the module-level
USA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are
trademarks of their respective owners. Date: 12/2015 V.01. Subject to change without notice.
(2) ItisnotallowedtomixP405withP300/P400/P600/P700inonestring.
P300 (for 60-cell modules)
P320 (for high-power 60-cell modules)
P400 (for 72 & 96-cell
modules)
P405 (for thin film
modules)INPUTRated Input DC Power(1) 300 320 400 405 WAbsolute Maximum Input Voltage (Vocatlowesttemperature) 48 80 125 Vdc
MPPTOperatingRange 8-48 8-80 12.5-105 VdcMaximumShortCircuitCurrent(Isc) 10 11 10.1 AdcMaximum DC Input Current 12.5 13.75 12.63 AdcMaximumEfficiency 99.5 %WeightedEfficiency 98.8 %OvervoltageCategory IIOUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)Maximum Output Current 15 AdcMaximum Output Voltage 60 85 VdcOUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)SafetyOutputVoltageperPowerOptimizer 1 Vdc
STANDARD COMPLIANCEEMC FCCPart15ClassB,IEC61000-6-2,IEC61000-6-3Safety IEC62109-1(classIIsafety),UL1741RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 VdcCompatibleinverters AllSolarEdgeSinglePhaseandThreePhaseinverters
Dimensions(WxLxH) 128x152x27.5/ 5x5.97x1.08
128x152x35/ 5x5.97x1.37
128x152x48/ 5x5.97x1.89 mm/in
Weight(includingcables) 760/1.7 830/1.8 1064/2.3 gr/lbInputConnector MC4CompatibleOutputWireType/Connector DoubleInsulated;MC4CompatibleOutputWireLength 0.95/3.0 1.2/3.9 m/ftOperatingTemperatureRange -40-+85/-40-+185 ˚C/˚FProtectionRating IP68/NEMA6PRelativeHumidity 0-100 %
(1)RatedSTCpowerofthemodule.Moduleofupto+5%powertoleranceallowed.
SolarEdge Power OptimizerModule Add-On for North AmericaP300 / P320 / P400 / P405
PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(2) SINGLE PHASE THREE PHASE 208V THREE PHASE 480V
MinimumStringLength (PowerOptimizers) 8 10 18
MaximumStringLength (PowerOptimizers) 25 25 50
Maximum Power per String 5250 6000 12750 WParallelStringsofDifferentLengths orOrientations Yes
Yingli Green EnergyYingli Green Energy Holding Company Limited (NYSE: YGE), known as “Yingli Solar,” is one of the world’s leading solar panel manufacturers with the mission to provide a� ordable green energy for all. Deploying more than 60 million solar panels worldwide, Yingli Solar makes solar power possible for communities everywhere by using our global manufacturing and logistics expertise to address unique local challenges.
19.9%CELL EFFICIENCY
10 YEARPRODUCT WARRANTY
0 - 5 WPOWER TOLERANCE
25 Years Linear Warranty
YLM72 CELL40mm SERIES
File name: Corporate Logo with Tagline / Vertical.ai
Power Your Life
Yingli’s Linear Performance Warranty
25
Years
201510510%
97%
91%
80%
Industry Standard Warranty
Yingli’s Linear Performance Warranty
25Years
201510510%
98%
92%
82%
Industry Standard Warranty
N-Type Mono Poly
Y I N G L I S O L A R .CO M
High Power DensityHigh conversion e� ciency and more power output per square meter.
DurabilityDurable PV modules, independently tested for harsh environmental conditions such as exposure to salt mist, ammonia and known PID risk factors.
Advanced GlassOur high-transmission glass features a unique anti-refl ective coating that directs more light on the solar cells, resulting in a higher energy yield.
PID ResistantTested in accordance to the standard IEC 62804, our PV modules have demonstrated resistance against PID (Potential Induced Degradation), which translates to security for your investment.
Choosing the best P-type monocrystalline cells, YLM series modules
are making the best out of your system. Trust in the expertise of
Yingli and well proven technology.
IMPROVED POWER NEVER SETTLE FOR LESS
DURABLE
PID-FREE
YLM 72 CELL 40mm SERIES
Yingli Green Energy Holding Co., [email protected] Tel: +86-312-2188055
© Yingli Green Energy Holding Co. Ltd. DS_YLM72Cell-36b_40mm_EU_EN_20160121_V04
Y I N G L I S O L A R .CO M
File name: Corporate Logo with Tagline / Vertical.ai
Power Your Life
G E N E R A L C H A R A C T E R I S T I C S
Dimensions (L / W / H) 1960mm / 990mm / 40mm
Weight 25.5kg
Yingli Partners:
T H E R M A L C H A R A C T E R I S T I C SNominal operating cell temperature NOCT °C 46 +/- 2
Temperature coe� cient of Pmax γ %/°C -0.42
Temperature coe� cient of Voc βVoc %/°C -0.32
Temperature coe� cient of Isc αlsc %/°C 0.05
O P E R AT I N G C O N D I T I O N SMax. system voltage 1000VDC
Max. series fuse rating 15A
Limiting reverse current 15A
Operating temperature range -40°C to 85°C
Max. static load, front (e.g., snow) 5400Pa
Max. static load, back (e.g., wind) 2400Pa
Max. hailstone impact (diameter / velocity) 25mm / 23m/s
C O N S T R U C T I O N M AT E R I A L SFront cover (material / thickness) low-iron tempered glass / 4.0mm
Cell (quantity / material / dimensions / number of busbars)
72 / monocrystalline silicon / 156mm x 156mm / 3 or 4
Frame (material ) anodized aluminum alloy
Junction box (protection degree) ≥ IP65
Cable (length / cross-sectional area) 1100mm / 4mm2
Plug connector (type / protection degree)
MC4 / IP68 or YT08-1 / IP67 or Amphenol H4 / IP68
PA C K A G I N G S P E C I F I C AT I O N SNumber of modules per pallet 26
Number of pallets per 40' container 24
Packaging box dimensions (L / W / H)
1995mm / 1145mm / 1170mm
Box weight 707kg
Unit: mm
• Due to continuous innovation, research and product improvement, the specifi cations in this product information sheet are subject to change
without prior notice. The specifi cations may deviate slightly and are not guaranteed.
• The data do not refer to a single module and they are not part of the off er, they only serve for comparison to diff erent module types.
1100
946990
1960
150
55
A
A
403
40
1960
577
577
Grounding holes8-Φ6
Mounting holes6-6.5×8
Drainage holes8-3×8
I
STC: 1000W/m2 irradiance, 25°C module temperature, AM1.5g spectrum according to EN 60904-3.Average relative e� ciency reduction of 3.0% at 200W/m2 according to EN 60904-1.
NOCT: open-circuit module operation temperature at 800W/m2 irradiance, 20°C ambient temperature, 1m/s wind speed.
E L E C T R I C A L P E R F O R M A N C EElectrical parameters at Standard Test Conditions (STC)Module type YLxxxD-36b (xxx=Pmax)
Power output Pmax W 340 335 330 325 320 315
Power output tolerances ΔPmax W 0/+5
Module e� ciency ηm % 17.5 17.3 17.0 16.7 16.5 16.2
Voltage at Pmax Vmpp V 37.9 37.6 37.2 36.9 36.6 36.2
Current at Pmax Impp A 8.97 8.91 8.86 8.81 8.75 8.69
Open-circuit voltage Voc V 47.3 46.9 46.6 46.2 45.9 45.5
Short-circuit current Isc A 9.35 9.32 9.29 9.27 9.24 9.21
Electrical parameters at Nominal Operating Cell Temperature (NOCT)Power output Pmax W 248.0 244.4 240.7 237.1 233.4 229.8
Voltage at Pmax Vmpp V 34.6 34.3 34.0 33.6 33.3 33.1
Current at Pmax Impp A 7.18 7.13 7.09 7.05 7.00 6.95
Open-circuit voltage Voc V 43.7 43.3 43.0 42.7 42.4 42.0
Short-circuit current Isc A 7.56 7.53 7.51 7.49 7.47 7.45
Warning:Read the Installation and User Manual in its entirety before handling, installing, and operating Yingli Solar modules.
Q U A L I F I C AT I O N S & C E R T I F I C AT E SIEC 61215, IEC 61730, CE, MCS, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007, PV Cycle, SA 8000
1240
32
SECTION A-A
DETAIL I
6.5
R3.25
8
R E S I D E N T I A L C O M M E R C I A L U T I L I T Y
241 N. 10th Street #6-7, Sacramento, CA 95811 www.DualRack.net
Product Line
DUAL RACK-HEAVY DUTY RAIL
®
Item # Product NameHD-144-C Heavy Duty Rail 144” - ClearHD-168-C Heavy Duty Rail 168” - ClearHD-204-C Heavy Duty Rail 204” - ClearHD-144-B Heavy Duty Rail 144” - BlackHD-168-B Heavy Duty Rail 168” - BlackHD-204-B Heavy Duty Rail 204” - Black
0.8830.9540.3720.000
Equivalent Properties Area,AxInertia,IxxInertia,IyyInertia,IxySx (Top)Sx (Bot)Sy (Left)Sy (Right)
0.538
Ordering SpecificsStandard Packaging 6 pcs/bundleDimension 144”/ 168”/ 204”Weight 1.03 lbs/ft
Material SpecificationsMaterial Designation 6005-T5Density (p) 168.56 lbs/ft³ (2.7 g/cm³)Coefficient of Thermal expansion (α ) 1.306E-05/ °F(2.35E-05/°C)Diffusivity (λ) 200.00 W/m-°KModulus of Elasticity (E) 10.152E06 Psi (7,000 kN/cm²)Shear Modulus (G) 3.916E06 Psi (2,700 kN/cm²)
т
Dual Rack Heavy Duty Rails are designed to be customized for solar PV arrays on residential, commercial and utility projects. Heavy Duty Rails are engineered for strength and durability and tested for spans of up to twelve feet.Pre-stamped engineering letters are available in multiple states. Installers prefer Dual Rack rails because they are strong, reliable, time saving, and available at the best price in the marketplace.
ADVANTAGES• Advanced Dual Rack design
• PE Certified in multiple states
• No special training required
• Save time and money on installations
• Less parts, two ways to install
• 2 sizes available: 14’ & 17’ – in silver & black
• 10 year limited warranty
• Conforms to UL STD 2703 and Class A Fire Rated
in^2in^4in^4in^4in^3in^30.693
0.4610.461
in^3in^3
Rail Span (ft¹)
a. The table above ONLY includes Dual Rack rail capacity check. It does not include roof attachment or roof capacity check.b. Wind risk category II per ASCE7-10. C. Topographic factor, kzt is 1.0. D. Maximum mean roof height is 30 ft.E. Average parapet height is 0 ft. F. Roof pitch is between 7 degree and 27 degree. G. Maximum solar panel weight is 50 lbs. H. Height of solar panel is between 2” and 10” to roof.*See Zone 2 & 3 span table calculation in Installation Manual/P.E. certification.
EXP Wind Speed Zone 1Snow Load (psf)
(Mph) 0.0 10.0 20.0 30.0 40.0 50.0 110 13.5 12.5 11.0 10.0 9.0 8.0 120 13.5 12.5 11.0 10.0 9.0 8.0 130 13.5 12.5 11.0 10.0 9.0 8.0
B 140 13.0 12.5 11.0 10.0 9.0 8.0 150 12.0 12.0 10.5 9.5 9.0 8.0 160 11.5 11.5 10.5 9.5 9.0 8.0 170 10.5 10.5 10.5 9.5 8.5 8.0 180 10.0 10.0 10.0 9.0 8.5 8.0 110 13.5 12.5 11.0 10.0 9.0 8.0 120 12.5 12.5 11.0 10.0 9.0 8.0 130 12.0 12.0 10.5 9.5 9.0 8.0
C 140 11.0 11.0 10.5 9.5 8.5 8.0 150 10.5 10.5 10.0 9.5 8.5 8.0 160 9.5 9.5 9.5 9.0 8.5 8.0 170 9.0 9.0 9.0 9.0 8.5 8.0 180 8.5 8.5 8.5 8.5 8.0 7.5
R E S I D E N T I A L C O M M E R C I A L U T I L I T Y
241 N. 10th Street #6-7, Sacramento, CA 95811 www.DualRack.net
Dual Rack-Heavy Duty Rail
Contact Info Distributor Info
Dual Rack Inc.241 N. 10th Street, # 6-7Sacramento, CA 95811916-492-2797
ROOF MOUNT GROUND MOUT
NoteDual Rack provides robust, long-life photovoltaic (PV) module mounting system solution for both roof mount and ground mount PV projects. The Heavy
Duty rail is one of the strongest supporting rails in the market, with the most competitive price. Pre-stamped structural certification is available in most of
states. Installation is simple and fast which ensures lower installation cost. Dual Rack allows modules to be mounted in both landscape and portrait
orientations.