4
SOLAR POWER PACKS ON-GRID SYSTEMS Module Mounting Structure : Pre-Galvanized Iron Structures designed to hold the modules firmly on roof top/ground against wind pressure & intense climatic conditions. Solar PV Modules : Solar Energy from Sun gets converted to DC Electrical Energy through PV modules. ON-Grid Inverter : Electrical Energy available from PV is in DC form which gets converted to AC with the help of Inverter. Existing Energy Meter : This meter records your consumption in kWh, which is the basis of billing, when the solar comes into play, you will observe the net kWh becomes less. User can export excess Solar Power by installing Net Meter. Connected Loads : Connected load or the self consumption runs in the same way as it does with the Grid but due to On Grid system the load is shared on Solar & Grid hence the consumption of Grid goes down. Grid Supply / DG supply: Provides support to the Solar Power available at the Inverter output.The system will stop working in absence of grid / DG supply. Save Up to 70% on your Electricity bills. Enjoy benefits of Accelerated depreciation. Make your idle Roof a Source of your Earning. A solution for rising tariffs of Electricity. Save diesel cost of your DG sets. Return on Investment in 3-4 years. Jakson Group with its diversified experience & expertise of putting up utility scale solar power plants, brings a ready to use Solar Solution for areas where electricity supply is available or the supply is maintained through DG set. These systems are ideal for reducing the Electricity Bill/Diesel consumption. 1 2 3 4 6 5

SOLAR POWER PACKS ON-GRID SYSTEMS - jakson.com Brochures/On-Grid Solar Power Packs.pdf · ON-Grid Inverter : Electrical Energy available from PV is in DC form which gets converted

Embed Size (px)

Citation preview

SOLAR POWER PACKSON-GRID SYSTEMS

Module Mounting Structure :Pre-Galvanized Iron Structures designed to hold the modules firmly on roof top/ground against wind pressure & intense climatic conditions.

Solar PV Modules :Solar Energy from Sun gets converted to DC Electrical Energy through PV modules.

ON-Grid Inverter :Electrical Energy available from PV is in DC form which gets converted to AC with the help of Inverter.

Existing Energy Meter :

This meter records your consumption in kWh, which is the basis of billing, when the solar comes into play, you will observe the net kWh becomes less. User can export excess Solar Power by installing Net Meter.

Connected Loads :

Connected load or the self consumption runs in the same way as it does with the Grid but due to On Grid system the load is shared on Solar & Grid hence the consumption of Grid goes down.

Grid Supply / DG supply:Provides support to the Solar Power available at the Inverter output.The system will stop working in absence of grid / DG supply.

Save Up to 70% on your

Electricity bills.

Enjoy benefits of

Accelerated depreciation.

Make your idle Roof a

Source of your Earning.

A solution for rising tariffs

of Electricity.

Save diesel cost of your

DG sets.

Return on Investmentin 3-4 years.

Jakson Group with its diversified experience & expertise of putting up utility scale solar power plants, brings a ready to use Solar Solution for areas where electricity supply is available or the supply is maintained through DG set. These systems are ideal for reducing the Electricity Bill/Diesel consumption.

1 2

3

4

6

5

SOLAR POWER PACKSON-GRID SYSTEMS

OPTIONS AVAILABLE

OPTIONS – I

+

PV Module PV Inverter

OPTIONS – II

+ +

PV Module PV Inverter Structure

OPTIONS – III

+ + +

PV Module PV Inverter Structure BOS

TECHNICAL SPECIFICATIONS & FEATURES OF THE SYSTEM

SINGLE PHASE PACKAGES

Solar Power Pack Rating 1.5 kWp - Single Phase 2 kWp - Single Phase 3 kWp - Single Phase 4 kWp - Single Phase 5 kWp - Single Phase

Model No. J-GTS-1.5-1.5-150-72 J-GTS-2.0-2.0-250-72 J-GTS-3.0-3.0-250-60 J-GTS-4.0-4.0-250-72 J-GTS-5.0-5.0-250-60

COMPONENTS

Modules (Qty. (No.)/ Rating (Wp) 10x150 8x250 12 X 250 16 X 250 20 X 250

Number of Cells/Vmp of Module 72/35.9 72/35.9 60 / 30 72 / 35.9 60 / 30

Inverter Power Rating (kW) 1.5 2 3 4 5

Inverter Topology Transformer less

Module Combinations : Series-Parallel 10(S) 8(S) 12(S) 8(S)-2(P) 10(S)-2(P)

Module Mounting Structure Pre-Galvanized - Flat Roof/Ground mounted

PV INVERTER FEATURES

INPUT PARAMETERS

Maximum DC Input Power (kW) 1.6 2.1 3.1 4.2 5.2

Maximum DC Input Voltage (Vdc) 500

MPPT DC Voltage Range (Vdc) 100 – 490

No. of MPPT trackers 1 1 1 2 2

Max. Input Current for each tracking (A) 11 13 13 X 2

DC Switch for MPPT Inverter Input Provided

OUTPUT PARAMETERS

Rated AC Output Power (kW @ P.f. = 1) 1.5 2.0 3.0 4.0 5.0

Phase/Rated Output Voltage (Vac)/connections Single /230/PN+PE

AC Voltage Range (Vac) 230V±20%

Output Frequency Range (Hz) 45 - 55

Power Factor 1

THD <3%

Consumption : Standby / Night <5W/Nil

PERFORMANCE PARAMETERS

Maximum Efficiency >96.3% >96.9% >97.5% >97.5% >97.6%

Euro Efficiency >96% >96% >96.5% >96.8% >96.8%

O O Operational Temperature -25 C to + 60 C

PROTECTIONS (For All Rating)

a) Anti - Islanding Provided d) AC Short Circuit Provided

b) Reverse Polarity Provided e) Ground Fault Monitoring Provided

c) Ingrus Protection (IP65) Provided f) All fault Current Monitoring Provided

Compliance IEC Standards IEC 62109, IEC 62116, VDE0126, IEC61683, IEC 62109, IEC 62116, VDE0126, IEC61683, IEC60068, IEC61727 IEC60068, IEC61727, IEC61000

The Balance of Supply (BOS) implies to :

• • • • Solar Cables & Wires MC4 Connectors Lightning Arrestor Fuses & Breakers

• • • Lugs & Connectors Earthing System Junction & Distribution Boxes

PROTECTIONS (For All Rating)

a) Anti - Islanding Provided Provided

Provided Provided

d) AC Short Circuit

e) Ground Fault Monitoringb) Reverse Polarity

c) Ingrus Protection (IP65) Provided Providede) All fault Current Monitoring

*The technical specifications are subject to change without any prior notice.

Compliance IEC Standards IEC 62109, IEC 62116, VDE0126, IEC61683, IEC60068 , IEC61727, IEC62116

TECHNICAL SPECIFICATIONS & FEATURES OF THE SYSTEM

THREE PHASE PACKAGES

Model No. J-GTS-8.0-10.0-250-72 J-GTS-10.0-10.0-250-60 J-GTS-15.0-15.0-250-60 J-GTS-20.0-20.0-250-60 J-GTS-30.0-30.0-250-60

Solar Power Pack Rating 8kWp-Three Phase 10kWp-Three Phase 15kWp-Three Phase 20kWp-Three Phase 30kWp-Three Phase

COMPONENTS

Inverter Power Rating (kW) 10 10 15 20 30

Inverter Topology Transformerless

Module Combinations : Series-Parallel 16(S)-2(P) 20(S)-2(P)

Module Mounting Structure Pre-Galvanized - Flat Roof/Ground mounted

20(S)-3(P) 20(S)-4(P) 20(S)-6(P)

Modules (Qty. No./Rating Wp) 32/250 40/250 60/250 80/250 120/250

Number of Cells/Vmp of Module 72/36 60/30 60/30 60/30 60/30

OUTPUT PARAMETERS

Phase/Rated Output Voltage (Vac)/connections Three / 400 / RYBN + PE

AC Voltage Range (Vac) 400 ± 20%

Output Frequency Range (Hz) 45 - 55

Power Factor 1

THD <3%

Consumption : Standby / Night <5W / Nil

10 15 20 30Rated AC Output Power (kW) 10

PERFORMANCE PARAMETERS

-25°C to + 60°C

Maximum Efficiency >98% >98.3%

Euro Efficiency >97.5% >97.9%

Operational Temperature

INPUT PARAMETERS

PV INVERTER FEATURES

Maximum DC Input Power (kW) 11.5 16.5 22.5 35.0

Maximum DC Input Voltage (Vdc) 1000

2 222 3

26X313X2Max. Input Current for each tracking (A)

DC Switch for MPPT Inverter Input Provided

250-950MPPT DC Voltage Range (Voc)

No. of MPPT trackers

J-GTS-25.2-30.0-300-72

25kWp-Three Phase

30

21(S)-4(P)

84/300

72/36.6

30

35.0

3

26X3

11.5

13X2 21X2 21X2

PV MODULES

• Superior Quality modules developed as per international benchmarks.

• Manufactured in the state of art manufacturing facility in Greater Noida, UP, conforming to relevant IEC standards.

• Sand & Dust Storm Resistant, ensures long life.

• Good quality tempered glass with Anti - reflective coating improves light transmission.

• Excellent performance in low light ensures better output.

• High Efficiency modules ensures better yield.

• 5 years of manufacturing & 25 Years of Limited Power Output Warranty**.

ON-GRID INVERTER

• High Frequency, transformer less design makes the product highly efficient and compact.

• High conversion efficiency of upto 98.3%, enables it to deliver better performance.

• Build with fast MPPT & Inverter technology with integrated safety conforming to IEC standard.

• IP65 Enclosure suitable for outdoor application ensures protection against extreme weather conditions.

• Anti - Islanding protection, protects against shock hazard at the time of grid failure.

• Wide temperature range from -25°C to 60°C enables working in all parts of the country.

• 5 Years of Manufacturing Warranty**.

MODULE MOUNTING STRUCTURE

• Superior Quality Pre - Galvanized material used for longer life.

• Strong mechanical strength which is capable of handling wind speed of up to 150km/hr.

• Pre-galvanized sheets makes the manufacturing process fast, providing uniform finishing.

• Good quality rust free hardware ensure better structural life.

• 10 Years of Manufacturing Warranty**.s Images shown are indicative. Actual product may vary

SYSTEM COMPONENTS

ADDITIONAL ACCESSORIES (OPTIONAL)

APPLICATION

No Grid Feed SystemThis unit enables protection againstgrid feed in case load is less than the Solar Power generated.

Remote Monitoring SystemThis unit provides real time monitoring and logging of the relevant parameters of the System.

SCHOOL / COLLEGES HOME & OFFICES INDUSTRIAL / COMMERCIAL HOSPITALS

JAKSON ENGINEERS LIMITED

A-43, Phase-II Extn., Hosiery Complex, Noida-201305, U.P., India

Tel.: +91-120-4302600, 4526100, 4740200 | Toll Free No. : 1800 103 2600

[email protected], [email protected] | www.jakson.com

**Warranty shall be provided to original buyer of the product from the company/company's authorized channel partner / System Integrator/Dealer. Warranty shall be void in case of improper handling/installation or operation and maintenance is not done as recommended or the product is serviced by unauthorized person.

SOLAR POWER PACKSON-GRID SYSTEMS

Auth. CP/Dealer