Auto-disables Syringes & Safety Box For Numerous Immunization Program

Page 3: Sol-Millennium   MVP Injection  Solution

Why AD ?Disposable Syringe Re-use Reuse of disposable syringes and needles leads to the transmission of blood-borne pathogens. To help prevent reuse of disposable syringes and needles, WHO, UNICEF and UNFPA urge that, by the end of 2003, all countries should use only auto-disable syringes for immunization, (WHO/V&B/99.25 – December 1999).

Page 4: Sol-Millennium   MVP Injection  Solution

Reuse of disposable and needles lead to : 20 million cases of hepatitis B (HBV) 2 million cases of hepatitis C (HCV) . Approximately 260 000 cases of HIV and other infections, such as

abscesses and septicemia each year (UNICEF, 2010)

Page 5: Sol-Millennium   MVP Injection  Solution

5 to 10 percent of some 16 billion injections administered worldwide each year are given for immunization.

Unsafe injection practices can seriously impede the progress made by immunization programmes and have a substantial effect on global immunization coverage.

The reuse of standard single-use disposable syringes and needles places the general public at high risk of disease and death.

Page 6: Sol-Millennium   MVP Injection  Solution

Hepatitis B virus: HBV is highly infectious and causes the highest number of infections: in developing and transitional countries 21.7 million people become infected each year, representing 33% of new HBV infections worldwide

Hepatitis C virus: Unsafe injections are the most common cause of HCV infection in developing and transitional countries, causing 2 million new infections each year and accounting for 42% of cases.

Human immunodeficiency virus: Globally nearly 2% of all new HIV infections are caused by unsafe injections. In South Asia up to 9% of new cases may be caused in this way. Such proportions can no longer be ignored.

Page 7: Sol-Millennium   MVP Injection  Solution

The auto-disable syringe

“ Safety boxes”, puncture-proof containers –

Equipment of choice for administering vaccines, both in routine immunization and mass campaigns, presents the lowest risk of person-to-person transmission of blood-borne pathogens (such as hepatitis B or HIV) .

For the collection and disposal of used disposable and auto-disable syringes, needles and other injection materials – reduce the risk posed to health staff and the general public by contaminated needles and syringes.Tips: AD syringes always need to be used together with safety box. It not just help solving syringe reuse presentation, but also help solving the medical waste management problems as well.

Page 8: Sol-Millennium   MVP Injection  Solution

Why Choose Us?Company Introduction

As a leading company focus on the deployment of safety medical devices, Sol-Millennium

Group dedicated us to provide world leading safety injection solutions, devote ourselves

to inject devices safe use and disposal. We has engineered SOL-JECT Auto-Disable (AD)

Syringe and Safety Boxes for immunization are helping to injection-associated

transmission of blood-borne pathogens, such as hepatitis B, hepatitis C and HIV

infections, in conjunction with the World Health Organization (WHO) and several other

international agencies.

Page 9: Sol-Millennium   MVP Injection  Solution

Building a Heath Tomorrow !

Integrated operation: we will identify your need and any problems to give you most satisfied solving solutions, from products providing and service delivery.

Strong Product Availability: We have mighty quantities availability to meet customer current demand. Customizes products, including special labeling, needle sizes and logos.

Quality assurance: our company compliance with ISO 13485, we hold WHO PQS both od AD syringes and safety box, which are matched used in immunization programme safety injection. Besides, we still hold CE for AD syringes.

Unique service: we supply both AD syringe and safety box which are needed to be used together.

Page 10: Sol-Millennium   MVP Injection  Solution

SOL-JECT Auto-Disable (AD) Syringe can prevent syringe reuse by locking and breaking the plunger after injection, especial for large immunization program.

Before use:

After use:

Specification: 0.05ml, 0.5ml, 1ml, 3ml, 5ml,10ml

Page 11: Sol-Millennium   MVP Injection  Solution

Important FeaturesMinimal dead spacePatented auto-disable mechanism design make sure syringe permanently disabled after markingsHands and finger stay behind the needle all timeEasy to use and require minimal trainingEasy to use and accurate dose measurementMaintains content sterility when unopened and not damagedMaximizes user efficiency; easily used by vaccineMeets international standards

Page 12: Sol-Millennium   MVP Injection  Solution
Page 13: Sol-Millennium   MVP Injection  Solution

Safety BoxesSOL-Millennium Safety Boxes is for safe and easy handing and destruction of used syringes and needles, it needs to be used together with AD syringes. When they are used consistently and correctly, safety boxes can help prevent disease-spreading needle stick injuries. As with AD syringes, health workers should practice assembling and using safety boxes.

Page 14: Sol-Millennium   MVP Injection  Solution

Specification WHO PQS CODE E10/010 5LVolume : 5 LitersExternal dimensions Before assembling : 590 x 300 x 4mmAfter assembling : 280 x 162 x 122mm Materials : recycled board, waterproof, and puncture proof Printing : brown background with black illustrations and textsThickness of walls : 1.2mmWeight fully assembled : 280gramsDiam. syringe inserts whole hole : 38mm

 ----- Sol-millennium® 5L Safety Box & Incineration Container, WHO PQS CODE E10/010----- for safe and easy handling and destruction of used syringes and needles.