Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power
Page 2: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Soft Starters Page

Single-phase Soft Starters SAS 3 - 22kW 1.01

Two-phase Soft Starters DUOSTART 1,5 - 5,5kW 1.03

VS II …-17 … 45 7,5 - 22kW 1.05

VersiStart II … LDS 3 - 15kW 1.07

VS II …-50 ... 75 25 - 37kW 1.09

VersiStart i II 18 … 200 7,5 - 110kW 1.11

Three-phase Soft Starters MICROSTART 1,5 - 3kW 1.13

MINISTART 1,5 - 11kW 1.15

DAS-T 7,5 - 55kW 1.17

NEW: VersiStart i III … -23 … 220 7,5 - 110kW 1.19

NEW: VersiStart i III … -255 … 1600 132 - 500kW 1.21

Dimensioning Rules for Soft Starters 1.23

Page 3: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

11/10

Features:

A single-phase controlled soft starter A all devices for pole-changing motors A dual-voltage, for 400V and 230V networks A terminal arrangement suitable for switchgear connection A for snap-mounting on 35mm standard rail A integrated bypass relay A no mains neutral conductor (N) required A special voltages up to 640V A also for single-phase applications A degree of protection IP 20 (SAS 3 ... SAS 11) degree of protection IP 00 (SAS 11PUST, 22PUST)

Function:

A soft start A 2 separately adjustable parameters starting torque, starting time A control contact for pole-changing motors

Upon Request:

A potential-free input control voltage 10 ... 30VDC

A SAS 3 up to SAS 11: standard up to 480V special voltages 500V up to 640V (all types in 100mm-housing)

A SAS 11PUST and SAS 22PUST: special voltages up to 690V

Technical Data SAS 3 5,5 7,5 11 11PUST 22PUST Mains / Motor voltage X1-X2 jumpered according to DIN EN 50160 (IEC 38)

160 ... 240V 10% 400V 15%

Mains / Motor voltage X1-X2 not jumpered according to DIN EN 50160 (IEC 38)

380 ... 480V 10%

Device nominal current 6,5A 12A 16A 25A 25A 45A Mains frequency 50/60HzMotor rating at 230V 1,5kW 3kW 4kW 5,5kW Motor rating at 400V 3kW 5,5kW 7,5kW 11kW 11kW 22kW min. motor current 10% of the device rated current Starting torque 0 ... 50% Starting time 0,5 ... 5s Reset time 200msmax. Switching cycle at 3x Ie and 5s tan 240/h 200/h 120/h 70/h 240/h 120/h max. Cross-sectional area 2,5mm² 16mm² I²t-Value Power semiconductor in A²s 265 610 800 1250 5000 10500 Ambient / Storage temperature 0°C ... 45°C / -25°C ... 75°C Weight / kg 0,3 0,3 0,5 0,5 2,7 3,0 Order number 20700.

4000320700.40005

20700.40007

20700.40011

20800.38011

20800.38022

Please observe supplementary sheet with dimensioning rules.

Soft StartersSAS 3 ... 11 SAS 11PUST, 22PUST

Soft Starters SAS 3 ... 11, SAS 11PUST, SAS 22PUST

Typical Applications:

packaging machinery sliding doors belt drives conveying machinery door drives of passenger and goods lifts limitation of starting current for transformers

1.01

control contactfor pole-changing

Motors

4T22T1 6T3 X3 X4

Controlfor

bypass

3L21L1 5L3

Trigger pulsegenerator

X1

Voltageselection

X2

Ramp-functiongenerator

M

t

Page 4: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Subject to change without notice.

Dimensions:

Connection Diagrams:

Soft Starters SAS 3 ... 11, SAS 11PUST, SAS 22PUST1.02

SAS 3/5,5 SAS 11PUST, 22PUST

100

SAS 7,5/11

73

120

12245

73

146175

Depth: 172mmfor M4

185

200

M~

SAS 3 ... 22PUST

Reverse circuit for pole-changing motors

X3

X3

L1 L1

K2

S21L1 3L2 5L3 X1 X2 X3 X4

SAS 3 ... 22PUST

PE

UbVbWb

4T22T1

K1

6T3

UaM3 ~ Wa

Va

K1

K2

L2L3NPEPEPEPE

K2 K31L1 3L2 5L3 X1 X2

K1 K3

K3

PE

UbVbWb 3

4T22T1

K1

6T3

12

Selectorswitch

L2L3NPE

K4

SAS 3 ... 22PUST

Standard circuit for pole-changing motors

~~PE 3M

4T2

3L2

2T1

1L1

6T3

X15L3 X2 X3 X4

K1

N

L1

L3L2

PE

Standard circuit

K1

~~PE 3M

SAS 3 ... 22PUST4T2

3L2

2T1

1L1

6T3

5L3 X2X1

Onswitch

N

L1

L3L2

PE

K1

Reverse circuit

Single-phase motor 230V AC

The terminal destinationfor SAS 11PUST and SAS 22PUST are likefollowing:

L1 - 1L1L2 - 3L2L3 - 5L3 U - 2T1 V - 4T2W - 6T3

By jumpering the contacts X1/X2 diveces SAS 3, SAS 5,5, SAS7,5 and SAS 11 can alsobe used for 220/240V networks.(no at SAS 11PUST and SAS 22PUST).

EMCThe limit values for emitted interference accordingto the applicable device standards do not rule outthe possibility that receivers and susceptible electronicdevices within a radius of 10m are subjectedto interference.If such interference, that is definitely attributable to theoperation of the soft starters "SAS", occurs, the emitted interference can be reduced by taking appropriatemeasures. Such measures are, e.g.:to connect reactors (3mH) or a suitable mains filter inseries before the soft starter, or to connect X-capacitors (0,15µ F) in parallel to the supply voltageterminals.

X4

K1

Ua

WaVa

K1 K2

K2

K3

K3

Reversingswitch

Selectorswitch

K4K5

K2 K3 S2

K5 0L R

S2

K4 K5

12

1L1

2T1

2T1

1L1

Single-phase application

Connection to single-phase networks

K1

X4

K2

K2

K1

0

K2

LS

R

Reversingswitch

Single-phase motor 230V AC

In the case of 400V single-phase networksremove jumper X1/X2

Start

3L2 5L3 X1 X2

4T2 6T3

SAS 3/5,5

X3 X4

M

L1N230V AC

X3

Start

SAS 7,5/11

3L2

4T2

5L3 X1 X2

6T3

N L1230V AC

L1230V AC

X4

M

Page 5: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

11/10

Features:

A two-phase controlled soft starter A easy mounting, also for retrofitting into existing plants A integrated bypass relay A no mains neutral conductor (N) required A parameterization by means of three potentiometers A economically priced replacement for star/delta switches A for mounting on top hat rail A current reduction during acceleration A very compact design, overall width from 45mm on A degree of protection IP20

Function:

A soft start and soft stopp potential-free control input for soft start and soft stop A 3 separately adjustable parameters starting torque, acceleration time, deceleration time A control (start/stop) with contact or voltage 10-42VDC

Options: (upon request)

A DUOSTART ... M (beginning of acceleration until end of deceleration) A DUOSTART ... S control (start/stop) with voltage 10-42VDC A external 24V supply voltage (wide voltage range capability)

Technical Data DUOSTART 1,5 3 5,5 Mains / Motor voltage according to DIN EN 50160 (IEC 38) 400V 10% 50/60Hz

Device nominal current 3,5A 6,5A 12A Motor rating at 400V mains voltage 1,5kW 3kW 5,5kW min. motor current 40% of the device rated current Starting torque 0 ... 80% Acceleration time 0,5 ... 12s Deceleration time 0,5 ... 12s Reset time 200msmax. Switching cycle at 3x Ie and 5s tan 200/h 120/h 70/h max. Cross-sectional area solid stranded

2x 2,5mm² 2x 1,5mm²

2x 2,5mm² 2x 1,5mm²

2x 2,5mm² 2x 1,5mm²

I²t-Value Power semiconductor in A²s 72 265 610 Ambient / Storage temperature 0°C ... 45°C / -25°C ... 75°C Weight / kg 0,4 0,4 0,4 Special voltages 230V 230V

480V230V480V

Order number Option „M“ Option “S”

21500.40001 21501.40001 21502.40001

21500.40003 21501.40003 21502.40003

21500.40005 21501.40005 21502.40005

Please observe supplementary sheet with dimensioning rules.

Soft StartersDUOSTART 1,5 ... 5,5

Soft Starters DUOSTART 1,5 ... 5,5

Typical Applications:

door and gate drives pumps, ventilators conveyorspackaging machinery transformer soft start

1.03

6T34T22T1

5L33L21L1

X4

X3

X2

X1

Supplyvoltage

Electronics

Triggerpulse

generatorRampcontrol

Controlfor

bypass

t an(t acc)

t aus(t dec)

M an (M acc)

Option

Startcontact

Operationalstatus

Page 6: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Subject to change without notice.

Dimensions:

Mounting dimensions W H D DUOSTART 1,5 ... 5,5 45mm 73mm 122mm

Connections Diagramms:

Soft Starters DUOSTART 1,5 ... 5,51.04

W

H

D

For pole-changing motors trimmer t aus to 0 (left stop)

Ua

X21L1 3L2 5L3 X1

DUOSTART 1,5 ... 5,54T22T1

PE

UbVbWb

M3 ~

K1

6T3

L2L3NPE

WaVa

K1 K2

K2

K1 K3

K3

K2 K3 S2 21

Selectorswitch

S - closed = soft start; S - open = soft stop

Standard circuit for pole-changing motors

~

DUOSTART 1,5 ... 5,5

M

L1

3PE

3L2

4T2

1L1

2T1

X25L3

6T3

X1

S

Standard circuit

L2L3NPE

L1

Ua

X21L1 3L2 5L3 X1

DUOSTART 1,5 ... 5,54T22T1

PE

UbVbWb

M3 ~

K1

6T3

L2L3NPE

K4

WaVa

K1 K2

K2

K1 K3

K3

K4Reversingswitch

K5

K2 K3 S2

K5 0L R

S2

K4 K5

21

Selectorswitch

The limit values for emitted interference accordingto the applicable device standards do not rule outthe possibility that receivers and susceptible electronicdevices within a radius of 10m are subjectedto interference.If such interference, that is definitely attributable to theoperation of the soft starters "DUOSTART", occurs,the emitted interference can be reduced by takingappropriate measures. Such measures are, e.g.:to connect reactors (3mH) or a suitable mains filter inseries before the soft starter, or to connect X-capacitors (0,15µ F) in parallel to the supply voltageterminals.

Reverse circuit for pole-changing motorsL1

EMC

S - closed = soft start; S - open = soft stop

~

DUOSTART 1,5 ... 5,5

M3PE

3L2

4T2

1L1

2T1

X25L3

6T3

X1

S

Reverse circuit

L2L3NPE

L1

K1

K2

K1 K2

K1

L

K2

0R

S1

Reversingswitch

Page 7: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Please observe supplementary sheet with dimensioning rules.

06/11

supplyvoltage

Triggerpulse

generator

6T32T1 4T2

Controlfor

bypass

5L31L1 3L2

Electronics

Rampcontrol

Start

U start

X8

X7RA2

t acc t dec

X3

X2

Boost

X6

X5RA1

X1

X4control supply U 24VDCat option "B"

+s

Features:

A two-phase controlled soft starter A controlled by microcontroller A optimized soft start A connection in the motor delta winding (cost saving via smaller rating) A current and torque reduction during acceleration A easy mounting, for snap-mounting on 35mm standard rail A integrated bypass relay A parameterization by means of three potentiometers A no additional control voltage required A no mains neutral conductor (N) required A economically priced substitute for star-delta starters A plug-in power terminals A control outputs with spring-loaded terminals A heat sink temperature monitoring A compact design, 45mm up to 32A and 52.5mm at 45A A degree of protection IP20

Function:

A soft acceleration and deceleration A potential-free control input for soft acceleration and deceleration A 3 separately adjustable parameters accel. time, start voltage, decel. time A boost-start selectable A potential-free relay output for operating state – unit bypassed – and failure

Options (upon request)

A special voltages 230V and 480V A wide voltage range 400-600V with external control supply voltage US 24VDC (B) A signaling contact (M)

beginning of acceleration until end of deceleration A motor PTC

Technical Data (standard) VS II 400-17 VS II 400-25 VS II 400-32 VS II 400-45 Mains / Motor voltage according to DIN EN 50160 (IEC 38) 400V 10% 50/60Hz

Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power dissipation - in operation - in standby

29,5W7,5W

29,5W7,5W

28,5W7,5W

27W7,5W

min. motor current 20% of the device rated current Acceleration time 0,5 … 10s Start voltage 40 … 80% Deceleration time 0,5 ... 10s Restart time 200msmax. Switching frequency at 3x Ie and 5s tan 50/h 35/h 25/h 10/h Cross-sectional area: Control terminals Power terminals

1,5mm²6mm²

1,5mm²16mm²

I²t - Power semiconductor in A²s 4900 4900 6050 6600 Tightening torque 1,2-1,5 Nm

11-13 Ibs in 1,5-1,7 Nm 13-15 Ibs in

Input resistance Control inputs 10kSwitching rating of relay output RA1/RA2 3A/250VAC; 3A/30VDC Overvoltage category / Pollution degree III (TT / TN systems) / 2 Installation class 3Surge strength 4kVAmbient / Storage temperature 0°C ... 45°C up to an altitude of 1000m / -25°C ... 70°C Weight / kg 1Special voltages (optional) 230V / 480V / wide voltage range 400-600V

with external control supply voltage US 24VDC 10%/150mA Order number 25700.40017 25700.40025 25700.40032 25700.40045

Soft StartersVS II …-17…45

Soft Starters VersiStart II …-17…45

Typical Applications:

door and gate drives pumps, ventilators, fans conveying systems packaging machines transport systems, assembly lines machine applications

1.05

Page 8: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Subject to change without notice.

Dimensions:

Mounting dimensions a b c d e VS II …- 17…32 125 158 53 45 173 VS II …- 45 125 158 53 52.5 178 All dimensions indicated in mm.

Connection Diagram:

Soft Starters VersiStart II …-17…451.06

On

Bypass

versi start II

12345678

0100%

0100%

0100%t

t

UStart

c

b

a

d

e

L1 L2 L3

T1 T2 T3

The limit values for emitted interference accordingto the applicable device standards do not rule out the possibility that receivers and susceptible electronic devices within a radius of 10m are subjectedto interference.If such interference, which is definitely attributable to theoperation of the soft starters "VersiStart II … ", occurs,the emitted interference can be reduced by takingappropriate measures.Such measures are, e.g.:To connect reactors (3mH) or a suitable mains filter inseries before the soft starter, or to connectX-capacitors (0.15µF) in parallel to thesupply voltage terminals.

S - closed = acceleration; S - open = deceleration

X3

~M

3L2

4T2

VersiStart II ...

3PE

1L1

2T1

5L3

6T3

X2

S

Standard circuit

L2

L3

N

PE

L1

EMC

X1

Star

t

X7X6X5 X8

X4

Ext. control voltage10 ... 24VDC

Fault Devicebypassed

Boos

t

RA1 RA2

F

Page 9: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

11/10

Features:

A two-phase controlled soft starter A controlled by microcontroller A easy mounting, also for retrofitting into existing plants A integrated bypass relay A no additional control voltage required A no mains neutral conductor (N) required A parameterization by means of three potentiometers A economically priced substitute for star-delta starters A current reduction during acceleration A circuit-board version for mounting onto DIN rail A plug-in control terminals A degree of protection IP00

Function:

A soft acceleration and deceleration A potential-free control input for

soft acceleration and deceleration A 3 separately adjustable parameters:

starting torque, accel. time, decel. time A two wire or three wire control via contact or voltage 10-42VDC A boost-start selectable

Options: (upon request)

A Special voltages 230V and 480V

Technical Data VS II 3 LDS VS II 5,5 LDS VS II 7,5 LDS VS II 11 LDS VS II 15 LDS Mains / Motor voltage according to DIN EN 50160 (IEC 38) 400V 10% 50/60Hz

Rated device current 6,5A 12A 15A 25A 32A Motor rating at 400V mains voltage 3kW 5,5kW 7,5kW 11kW 15kW min. motor current 20% of the device rated current Starting torque 0 ... 80% Acceleration time 0,5 ... 10s Deceleration time 0,5 ... 10s Restart time 200msmax. Switching frequency at 3x Ie and 5s tan 120/h 65/h 100/h 65/h 35/h Cross-sectional area FASTON 6.3 1,5mm² 2,5mm² litz 2,5mm² I²t – Power semiconductor in A²s 265 610 4900 4900 6050 Techn. parameter of relay output RA1 3A/250VAC; 3A/30VDC Techn. parameter of open-collector LO1 24VDC / 200mA Ambient / Storage temperature 0°C ... 40°C / -25°C ... 75°C Weight / kg 0,27 0,4 Special voltages (optional) 230V / 480V Order number 25723.40003 25723.40005 25723.40007 25723.40011 25723.40015 Please observe supplementary sheet with dimensioning rules.

Soft StartersVS II 3 ... 15LDS

Soft Starters VersiStart II 3 ... 15LDS

Typical Applications:

door and gate drives pumps, ventilators conveying systems packaging machines

1.07

Supplyvoltage

Triggerpulse

generator

6T32T1 4T2

Controlfor bypass

5L31L1 3L2

Electronics

Rampcontrol

Start

M an(M acc)

X2Option

X1

RA1

X6

t an(t acc)

t aus(t dec)

X5

X7

Boost

X3 X8LO1

X4Stop

Page 10: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Subject to change without notice.

Dimensions:

Mounting dimensions a b c d e f g h VS II 3 ... 5.5LDS 102,5 108,5 98,5 92,5 82,5 5,0 55,0 40 VS II 7.5 ... 15LDS 102,5 139,0 129,0 92,5 82,5 5,0 55,0 40 All dimensions indicated in mm.Connection Diagrams:

Soft Starters VersiStart II 3 ... 15LDS1.08

X1 d a

cb

35m

m

hg

f

3L2

6T34T2

5L32T1

1L1

e

for pole-changing motors turn trimmer t aus to 0 (left stop)

The limit values for emitted interference according to theapplicable device standards do not rule out the possibilitythat receivers and susceptible devices within a radius of 10m are subjected to interference.If such interference, which is definitely attributable to theoperation of the soft starters "VersiStart II...LDS", occurs,the emitted interference can be reduced by takingappropriate measures.Such measures are, e.g.:To connect reactors (3mH) or a suitable mains filter inseries before the soft starter, or to connect X-capacitors(0.15µ F) in parallel to the supply voltage terminals.

Ua

X61L1 3L2 5L3 X5

4T2VersiStart II 3 ... 15LDS

2T1

PE

UbVbWb

M3 ~

K1

6T3

L2L3NPE

WaVa

K1 K2

K2

K1 K3

K3

K2 K3 S2 21

Selectorswitch

S - closed = acceleration; S - open = deceleration

Standard circuit for pole-changing motors

X6

~M

3L2

4T2VersiStart II 3 ... 15LDS

L1

3PE

1L1

2T1

5L3

6T3

X5

S

Standard circuit

L2L3NPE

L1

Ua

X61L1 3L2 5L3 X5

4T2VersiStart II 3 ... 15LDS

2T1

UbVbWb

M3 ~

K1

6T3

L2L3NPE

K4

WaVa

K1 K2

K2

K1 K3

K3

K4Reversingswitch

K5

K2 K3 S2

K5 0L R

S2

K4 K5

21

Selectorswitch

Reversing circuit for pole-changing motorsL1

EMC

S - closed = acceleration; S - open = deceleration

X6

~M

3L2

4T2VersiStart II 3 ... 15LDS

3

1L1

2T1

5L3

6T3

X5

S

Reversing circuit

L2L3NPE

L1

K1

K2

K1 K2

K1

L

K2

0R

S1

Reversingswitch

PE

PE

Page 11: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Please observe supplementary sheet with dimensioning rules.

11/10

Features:

A two-phase controlled soft starter A controlled by microcontroller A optimized soft start A heatsink temperature detection A connection in the motor delta winding (cost saving via

smaller rating) A current and torque reduction during acceleration A easy mounting, also for retrofitting into existing plants A integrated bypass relay A parameterization by means of four potentiometers A no additional control voltage required A no mains neutral conductor (N) required A economically priced substitute for star-delta starters A control outputs with spring-loaded terminals A compact design, 103mm width A degree of protection IP20

Function:

A soft acceleration and deceleration A potential-free control input for

soft acceleration and deceleration A 4 separately adjustable parameters

accel. time, start voltage, decel. time, max. start current

A boost-start selectable A Motor PTC A current controlled start-up with external transformer (transformer is included in delivery) A potential-free control output for operating state – unit bypassed – and failure

Options: (upon request)

A special voltages 230V and 480V A wide voltage range 200-400V or 400-600V with external control

supply voltage US 24VDC (option B)

Technical Data (standard) VS II 400-50 VS II 400-65 VS II 400-75 Mains / Motor voltage according to DIN EN 50160 (IEC 38) 400V 10% 50/60Hz

Rated device current 50A 65A 75A Motor rating at 400V mains voltage 25kW 30kW 37kW max. Power dissipation - in operation - in standby

30W10W

min. motor current 20% of the device rated current Acceleration time 0,5 … 10s Start voltage 40 … 80% Deceleration time 0,5 ... 10s max. Start current 200% - 500% of the device rated current Restart time 200msmax. Switching frequency at 3x Ie and 10s tan 35/h 25/h 30/h I²t - Power semiconductor in A²s 6600 11200 25300 Cross-sectional area: Control terminals Power terminals

0,2 - 2,5mm²/24 – 12 AWG solid 1 - 35mm², 18 – 2 AWG / stranded 1 – 25mm², 18 – 3 AWG

Tightening torque (power terminals) 25mm² = 2,5 Nm 35mm² = 4,5 Nm 25mm² = 22 Ibs in 35mm² = 40 Ibs in

Input resistance Control inputs 10kSwitching rating of relay output RA1/RA2/RA3 3A/250VAC; 3A/30VDC Overvoltage category / Pollution degree III (TT / TN systems) / 2 Installation class 3Surge strength 4kVAmbient / Storage temperature 0°C... 45°C up to an altitude of 1000m / -25°C ... 70°C Weight / kg 1,5 1,5 2,2 Special voltages (optional) 230V / 480V /wide voltage range 200-400V or 400-600V

with external control supply voltage US 24VDC 10%/150mA Order number 25700.40050 25700.40065 25700.40075

Soft StartersVS II …-50…75

Soft Starters VersiStart II …-50…75

Typical Applications:

door and gate drives packaging machines pumps, ventilators, fans transport systems, assembly lines conveying systems machine applications

1.09

6T32T1 4T2

5L31L1 3L2

X12

X11RA2

X3

X2

X10

X9RA1

X14 X13RA3

I T

U USupplyvoltage

Triggerpulse

generator

Controlfor

bypass

Electronics

Ramp control

t acc t dec

U start

Start

Boost

X1 X4 X7 X8 X5 X6

I

Page 12: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Subject to change without notice.

Dimensions:

Mounting dimensions a b c d e VS II …- 50…65 103 230 125 86 220 VS II …- 75 103 230 140 80 220All dimensions indicated in mm.

Connenction Diagramm:

Soft Starters VersiStart II …-50…751.10

1L1 3L2 5L3

2T1 4T2 6T3

d

e

a

b

c

X3

~M

3L2

4T2VersiStart II ...

3PE

1L1

2T1

5L3

6T3

X2

Standard circuit

L2L3NPE

L1

X1

Star

t

X11X10X9 X12

X4

ext. control voltage10 ... 24VDC

FaultDevicebypassed

Boos

t

RA1 RA2

F

X13 X14RA3

Motorruns

X5 X6

X7 X8

currenttransformer

The limit values for emitted interference accordingto the applicable device standards do not rule out the possibility that receivers and susceptible electronic devices within a radius of 10m are subjectedto interference.If such interference, which is definitely attributable to theoperation of the soft starters "VersiStart II … ", occurs,the emitted interference can be reduced by takingappropriate measures.Such measures are, e.g.:To connect reactors (3mH) or a suitable mains filter inseries before the soft starter, or to connectX-capacitors (0.15µF) in parallel to thesupply voltage terminals.

EMCMotorthermistor

Page 13: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

03/11

Control

Control voltage

Triggerstage

Monitoring

2/T1 6/T34/T2

1/L1 5/L33/L2

Voltagesupply

A1 A3

Controlinputs

2 Relayoutputs

Thermistor

A2

0102

13142324

B4 B5

Controlfor

bypass

Features:

A two-phase controlled soft starter A controlled by microcontroller A integrated bypass relay A current and torque reduction during acceleration A integrated motor overload protection A motor PTC connection A voltage range 200 - 440V or 200 - 575V A degree of protection: IP20 (up to 100A), IP00 (from 140A up)

Function:

A 2 relay outputs A acceleration time monitoring A Adjustable parameters: - rated motor current - current ramp - current limit - soft stop – ramp time - motor protection class - output relay function - phase rotation protection

Accessories:

A ext. operating panel and interface (29000.25901) A USB module (29000.25910) A DeviceNet module (29000.25903) A Modbus module (29000.25904) A Profibus module (29000.25905) A Finger protection (29000.25907)

Technical Data VS i II 440 - 18C1 34C1 42C1 48C1 60C1 75C1 85C1 100C1 140C1 170C1 200C1 18C2 34C2 42C2 48C2 60C2 75C2 85C2 100C2 140C2 170C2 200C2Mains voltage according toDIN EN 50160 (IEC 38) 200-440V 45-66Hz

VS i II 575- 18C1 34C1 42C1 48C1 60C1 75C1 85C1 100C1 140C1 170C1 200C1 18C2 34C2 42C2 48C2 60C2 75C2 85C2 100C2 140C2 170C2 200C2Mains voltage according toDIN EN 50160 (IEC 38) 200-575V 45-66Hz Rated device current in A 18A 34A 42A 48A 60A 75A 85A 100A 140A 170A 200A Motor rating at 400V in kW 7,5 15 18,5 22 30 37 45 55 75 90 110 Current ramp 2s, 5s, 15s with 150%, 200% and 250% In Current limit 250%, 275%, 300%, 325%, 350%, 375%, 400%, 425%, 450% In Motor protection class adjustable Deceleration time 2s – 20s Switching frequency 4x Ie and 6s AC 53b 10/h AC 53b 6/h Techn. parameter of relay outputs 6A/30VDC; 2A/400VAC Ambient temperature -10°C…+40°C (+60°C Derating) Control voltage C1: 110-240VAC -15%/+10% 380-440VAC -15%/+10%; C2: 24VDC/24 VAC 20%Weight / kg 2,4 4,3 6,8 Order number: 440V/C1 25900.44… 018 034 042 048 060 075 085 100 140 170 200440V/C2 25901.44… 018 034 042 048 060 075 085 100 140 170 200 575V/C1* 25900.57… 018 034 042 048 060 075 085 100 140 170 200 575V/C2* 25901.57… 018 034 042 048 060 075 085 100 140 170 200 * units with 575V are not available ex stock, upon request

Soft Starters VS i II 18 … 200

Soft Starters VersiStart i II 18 … 200 1.11

Typical Applications:

pumps, ventilators compressors mills, crushers, presses conveying systems drives with high-inertia starting

Page 14: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Subject to change without notice.

A3 A1 A2 01 02

A3 A1 A2 01 02

110 - 240VAC24VAC/24VDC

STAR

T

STOP

START/STOP

A3 A1 A2 01 02

A3 A1 A2 01 02

380 - 440VAC

STAR

T

STOP

START/STOP

Two - wire

Three - wire

Dimensions:

Connection Diagram:

B (mm) H (mm) T (mm) VS i II…-18 98 203 165 VS i II…-34 98 203 165 VS i II…-42 98 203 165 VS i II…-48 98 203 165 VS i II…-60 98 203 165 VS i II…-75 145 215 193 VS i II…-85 145 215 193 VS i II…-100 145 215 193 VS i II…-140 202 240 214 VS i II…-170 202 240 214 VS i II…-200 202 240 214

Soft Starters VersiStart i II 18 … 200

B

TH

3

2

1L1 L2 L3

1/L1 3/L2 5/L3 A3 A1(+)

A2(-)

01 02 B4 B5

Thermistor

Controlvoltage

1 - C12 - C13 - C2

380 - 440VAC110 - 240VAC24VAC/24VDC

Maincontactor

Progr.output

2/T1 4/T2 6/T3

13 14 23 24

M3 ~

1.12

Page 15: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

11/10

Features:

A three-phase controlled soft starter A easy mounting, also for retrofitting into existing plants A terminal arrangement suitable for switchgear connection A for snap-mounting on 35mm standard rail A integrated bypass relay A no mains neutral conductor (N) required A functional peak current reduction A degree of protection IP 20

Function:

A soft acceleration and deceleration A 4 separately adjustable parameters

starting torque, acceleration time, soft stop torque, deceleration time

A soft start and soft stop via control contact possible

Upon Request:

A potential-free input -control voltage 10 ... 30VDC

Option: (upon request)

A „SST“ - pluggable

Technical Data MICROSTART 1,5 3

Mains / Motor voltage according to DIN EN 50160 (IEC 38) 400V 15% 50/60Hz

Device nominal current 4A 6.5A Motor rating 1,5kW 3kW min. motor current 10% of the device rated current Adjustment range of starting torque 0 ... 80% Adjustment range of acceleration time 1 ... 15s Adjustment range of soft stop torque 20 ... 80% Adjustment range of deceleration time 0 ... 15s Reset time 200msmax. Switching cycle at 3x Ie and 10s tan 120/h 60/h max. Cross-sectional area 2,5mm² I²t-Value Power semiconductor in A²s 40 450 Ambient / Storage temperature 0°C ... 45°C / -25°C ... 75°C Weight / kg 0,75 0,75 Order number Option „SST“

21300.38001 21304.38001

21300.38003 21304.38003

Please observe supplementary sheet with dimensioning rules.

Soft StartersMICROSTART 1,5 / 3

Soft Starters MICROSTART 1,5 / 3

Typical Applications:

pumps, ventilators belt drives, driving pulleys / coil winders conveying machinery compressors

1.13

Control forbypass

Triggerpulse

generator

U V W

L3L1 L2

Supplyvoltage

Rampcontrol

Startcontact

M an(M acc)

M aus(M dec)

t an(t acc)

t aus(t dec)

Electronics

Page 16: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Subject to change without notice.

Dimensions:

Connection Diagram:

Soft Starters MICROSTART 1,5 / 31.14

166

106

55

23

118

55

128

Option "SST"MICROSTART 1,5/3

168All dimensions in mm!

EMCThe limit values for emitted interference accordingto the applicable device standards do not rule outthe possibility that receivers and susceptible electronicdevices within a radius of 10m are subjectedto interference.If such interference, that is definitely attributable to theoperation of the soft starters "MICROSTART", occurs,the emitted interference can be reduced by takingappropriate measures. Such measures are, e.g.:to connect reactors (3mH) or a suitable mains filter inseries before the soft starter, or to connect X-capacitors (0,15µ F) in parallel to the supply voltageterminals.

For pole-changing motors trimmer t aus to 0 (left stop)

Ua

U V 1 3V W

PE

UbVbWb

M3 ~

K1

MICROSTART 1,5 / 3L2L1

L2L3NPE

L3 PE

WaVa

K2

K2 K1

K3K2

K1 K3

K3

S2 21

Selectorswitch

S - closed = soft start; S - open = soft stop

Standard circuit for pole-changing motors

~

MICROSTART 1,5 / 3

M

L2

L1

3PE

U V

L1 L3 PE

W 1 3

Standard circuit

L2L3NPE

L1

Ua

U V W 1 3

PE

UbVbWb

M3 ~

K1

MICROSTART 1,5 / 3L2L1

L2L3NPE

K4

L3 PE

WaVa

K2

K2 K1

K3K2

K1 K3

K3

K4Reversingswitch

K5

S2

K5 0L R

S2

K4 K5

21

Selectorswitch

Reverse circuit for pole-changing motorsL1

S

S - closed = soft start; S - open = soft stop

~

MICROSTART 1,5 / 3

M

L2

3PE

U V

L1 L3 PE

W 1 3

Reverse circuit

L2L3NPE

L1

K1

K2

K1 K2

K1

L

K2

0R

S1

Reversingswitch

S

Page 17: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

11/10

Features:

A three-phase controlled soft starterA easy mounting, also for retrofitting into existing plants A terminal arrangement suitable for switchgear connection A for snap-mounting on 35mm standard rail A integrated bypass relay A extensive monitoring functions A robust metal housing A no mains neutral conductor (N) required A special voltages up to 600V A functional peak current reduction A degree of protection IP 20

Function:

A soft acceleration and deceleration A 4 separately adjustable parameters starting torque, acceleration time, soft stop torque, deceleration time A potential-free input for soft start or soft stop -control voltage 10 ... 30VDC A potential-free output for fault indication A potential-free output for operational status * -loadable with 250V/8A each A temperature monitoring A phase-failure monitoring during ramp-up

*- with standard devices closed, when power semiconductors are bridged - with option “S” closed from start of acceleration to end of deceleration

Technical Data MINISTART 1,5 3 5,5 7,5 11 Mains / Motor voltage according to DIN EN 50160 (IEC 38) 400V 15% 50/60Hz

Device nominal current 4A 6,5A 12A 16A 25A Motor rating 1,5kW 3kW 5,5kW 7,5kW 11kW min. motor current 10% of the device rated current Starting torque 0 ... 80% Acceleration time 1 ... 20s Soft stop torque 20 ... 80% Deceleration time 0 ... 20s Reset time 200msmax. Switching cycle at 3x Ie and 10s tan 120/h 60/h 20/h max. Cross-sectional area Control terminals Power terminals

1,5mm²4,0mm²

I²t-Value Power semiconductor in A²s 40 450 550 9100 9100 Ambient / Storage temperature 0°C .... 45°C / -25°C ... 75°C Weight / kg 1,2 1,2 1,35 1,5 1,5 Order number 21200.38001 21200.38003 21200.38005 21200.38007 21200.38011 Please observe supplementary sheet with dimensioning rules.

Soft StartersMINISTART 1,5 ... 11

Soft Starters MINISTART 1,5 ... 11

Typical Applications:

pumps, ventilators cranestravelling and rotary operating mechanisms conveying machinery washing machines, linen dryers

1.15

U WV

L1 L3L2enclosure

internal temperature

supplyvoltage

phase-failure

recognition

triggerpulse

generator

controlfor

bridging

monitoring

pulseinhibitor

electronicssupply

(braking time)t aus

(t dec)t an

(t acc)

M aus(M dec)

(braking current)

M an(M acc)

rampcontrol

Fault

Startcontact

Operationalstatus

Page 18: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Subject to change without notice.

Dimensions:

W H D Mounting dimensions 166mm 106mm 117mm

Connection Diagram:

Soft Starters MINISTART 1,5 ... 111.16

HW D

For pole-changing motors trimmer t aus to 0 (left stop)

Ua

10 11U V 95 6 7 8W

PE

UbVbWb

M3 ~

K1

MINISTART 1,5 ... 11L2L1

L2L3NPE

L3 PE

12

WaVa

K2

K2 K1

K3K2

K1 K3

K3

S2 21

Selectorswitch

Standard circuit for pole-changing motors

10 11

~

MINISTART 1,5 ... 11

M

L2

L1

3PE

U V

L1

W 5 6 7 8 9

L3 PE

Standard circuit

L2L3NPE

L1

12

Ua

10 11U V 95 6 7 8W

PE

UbVbWb

M3 ~

K1

MINISTART 1,5 ... 11L2L1

L2L3NPE

K4

L3 PE

12

WaVa

K2

K2 K1

K3K2

K1 K3

K3

K4Reversingswitch

K5

S2

K5 0L R

S2

K4 K5

21

Selectorswitch

Reverse circuit for pole-changing motors

The limit values for emitted interference accordingto the applicable device standards do not rule outthe possibility that receivers and susceptible electronicdevices within a radius of 10m are subjectedto interference.If such interference, that is definitely attributable to theoperation of the soft starters "MINISTART", occurs,the emitted interference can be reduced by takingappropriate measures. Such measures are, e.g.:to connect reactors (3mH) or a suitable mains filter inseries before the soft starter, or to connect X-capacitors (0,15µ F) in parallel to the supply voltageterminals.

L1

EMC

10 11

~

MINISTART 1,5 ... 11

M

L2

3PE

U V

L1

W 5 6 7 8 9

L3 PE

Reverse circuit

L2L3NPE

L1

K1

K2

K1

12

K2

K1

L

K2

0R

S1

Reversingswitch

S

- +10 ... 30VDC15mA

control via contactcontrol via controlvoltage

Page 19: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

11/10

Features:

A three-phase controlled soft starter A easy mounting, also for retrofitting into existing systems A terminal arrangement suitable for switchgear connection A integrated bypass contactor A no mains neutral conductor (N) required A functional peak current reduction A monitoring of heat sink temperature A monitoring of motor temperature via motor thermistor A potential-free control inputs and outputs A special voltages up to 690V A robust metal enclosure A degree of protection IP 20

Function:

A soft acceleration and deceleration A acceleration/deceleration via control contact or control voltage 10 ... 42VDC (selectable) A 4 separately adjustable parameters starting torque, acceleration time, soft stop torque, deceleration time A potential-free output for operational status* 250VAC/8A A fault signalling contact (250VAC/8A) A input for motor thermistor A for special voltages higher than 500V an external electronic supply (230VAC) is necessary.

* closed when power semiconductors are bridged, or closed from start of acceleration to end of deceleration

Technical Data DAS-T 7,5 11 15 22 30 37 55 Mains / Motor voltage (Standard) according to DIN EN 50160 (IEC 38) 400V 15% 50/60Hz (up to 690V upon request)

Device rated current 17A 25A 32A 48A 63A 75A 105A Motor rating 7,5kW 11kW 15kW 22kW 30kW 37kW 55kW min. motor current 10% of the device rated current Starting torque 0 ... 80% Acceleration time 0,5 ... 25s Soft stop torque 20 ... 80% Deceleration time 0 ... 15s Reset time 200msmax. Switching cycle at 3x Ie and 10s tan 120/h 100/h 80/h 60/h 40/h 40/h 20/h

1,5mm²Cross-sectional area Control terminals of connecting cable Power terminals 16mm² 35mm² I²t-Value Power semiconductor in A²s 3600 3600 8000 10500 18000 51200 125000 Ambient / Storage temperature 0°C ... 45°C / -25°C ... 75°C Weight / kg 3,8 3,8 4 4 7,8 8 8,2 Order number 20900.

4000720900.40011

20900.40015

20900.40022

20900.40030

20900.40037

20900.40055

Please observe supplementary sheet with dimensioning rules.

Soft StartersDAS-T 7,5 ... 55

Soft Starters DAS-T 7,5 ... 55

Typical Applications:

pumpsventilatorsconveying machinery dryers, washing machines compressors cranes, trolleys

1.17

Triggerpulse

generator

U V

Controlfor

bypass

W

L1 L2

Supplyvoltage

L3

Startcontact

Rampcontrol

M an(M acc)

M aus(M dec)

Operationalstatus

t an(acc) t aus(dec)

Motorthermistor

Faultindication

Controlelectronics

external electronicsupply 230VAC

option

Page 20: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Subject to change without notice.

Dimensions:

W [mm]

W’[mm]

H[mm]

H’[mm]

D[mm]

DAS-T 7,5 235 218 245 170 140 DAS-T 11 235 218 245 170 140 DAS-T 15 235 218 245 170 140 DAS-T 22 235 218 245 170 140 DAS-T 30 335 318 245 170 170 DAS-T 37 335 318 245 170 170 DAS-T 55 335 318 245 170 170

Connection Diagramms:

Soft Starters DAS-T 7,5 ... 551.18

H' H

W'

W

for M4

D

M~

Reversing circuit for pole-switching motors

Fault

11

Opera-tionalstatus

Opera-tionalstatus

for pole-changing motors turn trimmer t aus to 0 (left stop)

K2

S2L1 L2 L3PE 6 7

PE

UbVbWb

K1

T1 T2 T3DAS-T 7,5 ... 55

4PE

UaM3 ~ Wa

Va

K1

K2

5 1211Fault

Opera-tionalstatus9

L2L3NPE

L1

K2 K3102 L1 L2 L3PE

K1 K3

K3

PE

UbVbWb 3

K1

T1 T2 T3DAS-T 7,5 ... 55

4 5PE

1

Selectorswitch

L3NPE

L2L1

K4

9 10

Standard circuit for pole-changing motors

K1

S - closed = acceleration; S - open = deceleration

Opera-tionalstatus

PE T1 T2 T3 4

~M

3PE

L2DAS-T 7,5 ... 55

L1PE L39

5

Fault11 12

10 .. 42VDC

10S

+

6 7

Standard circuit

L2L3NPE

L1

K2

K2 K1

4 5PE T1 T2 T3

~M

3PE

L2L1 L3DAS-T 7,5 ... 55

9 10PE

L

Reversingswitch

0R

S1

L2L3NPE

L1

K1

Reversing circuit

The limit values for emitted interference according to the applicable device standardsdo not rule out the possibility that receiversand susceptible electronic devices within aradius of 10m are subjected to interference.If such interference, that is definitelyattributable to the operation of the soft starters"DAS", occurs, the emitted interference can bereduced by taking appropriate measures.Such measures are, e.g.:To connect reactors (3mH) or a suitable mainsfilter in series before the soft starter, or to connect X-capacitors (0.15µ F) in parallel to thesupply voltage terminals.

26 7

K1

Ua

WaVa

K1 K2

K2

12Fault

K3

K3

Reversingswitch

Selectorswitch

K4K5

K2 K3 S2

K5 0L R

S2

K4 K5

1

K111 12

K2

6 7

S

K2

EMC

K1

0L

K2

Reversingswitch

RS1

12

12

12

12

Page 21: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

11/10

Control voltage

Triggerstage

Monitoring

2/T1 6/T34/T2

1/L1 5/L33/L2

Controlwith

oper. unit

Voltagesupply

A4 A6 24VDC output

Remotecontrolinputs

Analogoutput

3 Relayoutputs

MotorPTC

A5

Control forbypass

Features:

A three-phase controlled digital-soft starter (7,5-800kW) A integrated Bypass up to 110kW (up to 500kW by end year 2011) A current and torque reduction during acceleration A Comprehensive and customizable motor protection A DC Braking - Contactorless A Display graphical LCD - Real time graphs of motor operating performance A Inside Delta (6-wire) connection A degree of protection: IP20 (up to 100A), IP00 (from 140A up) A motor PTC connection

Function:

A Emergency run A Forward or reverse jog direction. A Remote control inputs

(3x fixed, 1x programmable) A Relay outputs

(3x programmable) A 24VDC output A Analog output A divers Soft Start/Stop control types A units with 690V upon request

Accessories:

A Control Software A DeviceNet module (29000.25903) A Modbus module (29000.25904) A Profibus module (29000.25905) A USB module (29000.25910) A Finger protection (from 145A up, 29000.25909)

Technical Data VS i III 525 - 23C1 43C1 53C1 76C1 105C1 145C1 170C1 220C1 23C2 43C2 53C2 76C2 105C2 145C2 170C2 220C2 Mains voltage according toDIN EN 50160 (IEC 38) 200-525V 45-66Hz

VS i III 690- 23C1 43C1 53C1 76C1 105C1 145C1 170C1 220C1 23C2 43C2 53C2 76C2 105C2 145C2 170C2 220C2 Mains voltage according toDIN EN 50160 (IEC 38) 380-690V 45-66Hz

Rated device current in A 23A 43A 53A 76A 105A 145A 170A 220A Motor rating at 400V in kW -7,5 -15 -22 -30 -55 -60 -75 -110 I²t-Value Power semiconductor in kA²s 1,15 8 15 15 125 125 320 320 Acceleration Constant current, Current ramp, “Adaptive Acceleration Control”, Torque Control Deceleration Timed voltage ramp soft Stopp, Brake Switching frequency 3x Ie and 10s AC53b 3.0 - 10:350 10/h AC53b 3.0 – 10:590 10/h Techn. parameter of relay outputs 10A/250VAC resistive; 5A/250VAC AC15 Ambient temperature -10°C…+40°C (+60°C Derating) Control voltage C1: 110VAC; 220VAC; -15%/+10%; C2: 24VDC/24VAC 20% Weight / kg 3,2 3,5 4,8 16 Order number: 525V/C1 2S000.50..* 023 043 053 076 105 145 170 220525V/C2 2S001.50..* 023 043 053 076 105 145 170 220

Soft Starters VersiStart i III ...-23 … 220

Typical Applications:

pumps, ventilators compressors mills, crushers, presses, conveying systems drives with high-inertia starting machines with gear units, belt or chain drives

Soft StartersVS i III ...-23 … 220

1.19

Page 22: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Subject to change without notice.

A

65

64

5857565455+5341-40+A6A5A4

E

5/L3

3/L2

1/L1 1/T1

4/T2

6/T3

13142122243334

L1B

L2B

L3B

DC

B

A

E

Dimensions:

Connection Diagram:

ModelA

mmB

mmC

mmD

mmE

mmWeight

kgVS i III -23 VS i III -43 VS i III -53

192 3.2

VS i III -76 3.5

VS i III -105

156.5 124 294.5 278

2234.8

VS i III -145 VS i III -170 VS i III - 220

282 250 438 380 250 16

Soft Starters VersiStart i III 23 … 2201.20

Page 23: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

11/10

Control voltage

Triggerstage

Monitoring

2/T1 6/T34/T2

Controlwith

oper. unit

Voltagesupply

A4 A6 24VDC output

Remotecontrolinputs

Analogoutput

3 Relayoutputs

MotorPTC

A51/L1 5/L33/L2L1B L2B L3B

Features:

A three-phase controlled digital-soft starter (7,5-800kW) A integrated Bypass up to 110kW (up to 500kW by end year 2011) A current and torque reduction during acceleration A Comprehensive and customizable motor protection A DC Braking - Contactorless A Display graphical LCD - Real time graphs of motor operating performance A Inside Delta (6-wire) connection A degree of protection: IP20 (up to 100A), IP00 (from 140A up) A motor PTC connection

Function:

A Emergency run A Forward or reverse jog direction. A Remote control inputs

(3x fixed, 1x programmable) A Relay outputs

(3x programmable) A 24VDC output A Analog output A divers Soft Start/Stop control types A units with 690V upon request

Accessories:

A Control Software A DeviceNet module (29000.25903) A Modbus module (29000.25904) A Profibus module (29000.25905) A USB module (29000.25910) A Finger protection (29000.25909)

Upon request:

A units up to 500kW

N = without bypass (integrated Bypass by end year 2011)

Technical Data VS i III 525 - 255N C1 380N C1 430N C1 650N C1 790N C1 930N C1 255N C2 380N C2 430N C2 650N C2 790N C2 930N C2 Mains voltage according toDIN EN 50160 (IEC 38) 200-525V 45-66Hz

VS i III 690- 255N C1 380N C1 430N C1 650N C1 790N C1 930N C1 255N C2 380N C2 430N C2 650N C2 790N C2 930N C2 Mains voltage according toDIN EN 50160 (IEC 38) 380-690V 45-66Hz

Rated device current in A 255A 380A 430A 650A 790A 930A Motor rating at 400V in kW -132 -185 -220 -315 -400 -500 I²t-Value Power semiconductor in kA²s 320 320 320 1200 2530 4500Acceleration Constant current, Current ramp, “Adaptive Acceleration Control”, Torque ControlDeceleration Timed voltage ramp soft Stopp, Brake Switching frequency 3x Ie and 10s AC53b 3.0 – 10:590 10/h Techn. parameter of relay outputs 10A/250VAC resistive; 5A/250VAC AC15 Ambient temperature -10°C…+40°C (+60°C Derating) Control voltage C1: 110VAC; 220VAC -15%/+10%; C2: 24VDC/24 VAC 20% Weight / kg 25 50,5 53,5 Order number: 525V/C1 2S010.50..*1 255 380 430 650 790 930525V/C2 2S011.50..*1 255 380 430 650 790 930

Soft Starters VersiStart i III ...-255 … 1600

Typical Applications:

pumps, ventilators compressors mills, crushers, presses, conveying systems drives with high-inertia starting machines with gear units, belt or chain drives

Soft StartersVS i III ...-255 … 1600

1.21

Page 24: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Subject to change without notice.

DC

B

A

E

A

65

64

5857565455+5341-40+A6A5A4

E

5/L3

3/L2

1/L1 1/T1

4/T2

6/T3

13142122243334

L1B

L2B

L3B

Dimensions:

Connection Diagram:

ModelA

mmB

mmC

mmD

mmE

mmWeight

kgVS i III -255N 390 320 417 400 281 25

VS i III -380N VS i III -430N

50.5

VS i III -650N VS i III -790N VS i III -930N

430 320 545 522 299 53.5

Soft Starters VersiStart i III 255 … 16001.22

Page 25: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Dimensioning Rules for Soft Starters

04/11

All data sheets and commissioning instructions are available on our homepage at: www.peter-electronic.com.

Configuration instructions

The two following diagrams for an 11kW-drive operated at nominal load show the waveforms of electrical and mechanical quantities of the drive during the ramp-up phase, both with and without soft starter:

Ramp-up of a three-phase asynchronous motor directly connected to the mains (at nominal load)

Ramp-up of a three-phase asynchronous motor with soft starter (at nominal load)

Both groups of curves show the complete acceleration and deceleration phase.

In this connection, especially the waveform of the current during ramp-up with a soft starter is of interest. Depending on the adjusted starting voltage (boost), this current increases more or less steeply until nominal speed is reached. For the following load diagrams (thermal load), the mean value of that current is to be used which is formed by the current flowing at the starting point and the current flowing when nominal speed is reached (see example).

The following diagrams show how the maximum starting frequency (in starts per hour) depends on the ramp-up time and the mean starting current flowing during ramp-up. The curves represent the thermal ratio of the heat generated in the power semiconductors and the possible dissipation of heat by the integrated heat sinks, i.e., a high starting frequency in combination with a large mean starting current causes intense heating by the power semiconductors. If, in addition, a long ramp-up time is required for the starting operation, the number of starts possible within a certain unit of time reduces accordingly.

1.23

Motor current

Motor voltage

Torque

Speed

Speed

Motor current

Motor voltage

Torque

Page 26: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Dimensioning Rules for Soft Starters

The following example is to explain how to select a soft starter:

Assumption: Motor shaft power: 15kW Nominal/rated motor current: 29.5A max. Ramp-up time: 6s Mean starting current to be expected: 90A (no high-inertia starting) max. Starting frequency: 40 starts/h

In compliance with the power rating of the motor, a VersiStart II 400-32 soft starter is selected (acc. to the data sheet it is suitable for 15kW motors, Ie = 32A). However, when checking the number of starts per hour possible with this device under these conditions, it turns out that this device is not suitable:

VersiStart II 400-32

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe

1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

25 Starts/h

Ramp-up time 6s

When dividing the starting current of 90A to be expected by the nominal current of 32A of the soft starter VersiStart II 400-32, this gives approx. 3 x Ie (90A/32A) of the soft starter. Consequently, a maximum starting frequency of 60 starts per hour is permissible for this device, i.e., in this case VersiStart II 400-32 would be overloaded.

This is only possible by reducing the ramp-up time. As demonstrated by the two below diagrams, the ramp-up time maximally possible for the application of a VersiStart II 400-32 would be approx. 3,7s.

VersiStart II 400-32

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe

1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h40 Starts/h

max. Ramp_up time approx. 3,7s

1.24

Page 27: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Dimensioning Rules for Soft Starters

04/11

If it is due to technological reasons not possible to go below the specified ramp-up time of 6s, a device that complies with the requested parameters has to be used.

When looking at the characteristic curves, it becomes clear that, for this case of application, a DAS-T 15 is suitable. With a threefold nominal current of the soft starter, i.e., 3 x Ie (90A/32A), and a ramp-up time of 6s, this device has a starting frequency of approx. 130 starts/h.

Since only 40 starts/h are required, this device is optimally designed to withstand the most unfavorable thermal loading.

DAS-T 15

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe

1,00

10,00

100,00

1000,00

1 10 100

Anlaufzeit/Ramp-up time (s)

Star

ts/h

Ramp-up time 6s

130 Starts/h

1.25

Page 28: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Dimensioning Rules for Soft Starters

Load diagrams:

SAS3, SAS11 PUST, DAS-T 7,5, MINISTART 1,5 ... 5,5, MICROSTART 1,5

1,00

10,00

100,00

1000,00

1 10 100

Anlaufzeit/Ramp-up time (s)

Star

ts/h 2xIe

3xIe4xIe5xIe6xIe

SAS 5,5, DAS-T 11, MINISTART 1,5 ... 5,5B, DUOSTART 1,5

1,00

10,00

100,00

1000,00

1 10 100

Anlaufzeit/Ramp-up time (s)

Star

ts/h 2xIe

3xIe4xIe5xIe6xIe

SAS 7,5, SAS 22PUST, DAS-T 22, MICROSTART 3, DUOSTART 3, MINISTART 7,5

1,00

10,00

100,00

1000,00

1 10 100

Anlaufzeit/Ramp-up time (s)

Star

ts/h

2xIe3xIe4xIe5xIe6xIe

1.26

Page 29: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Dimensioning Rules for Soft Starters

04/11

SAS 11, DAS-T 30, DAS-T 37, DUOSTART 5,5

1,00

10,00

100,00

1000,00

1 10 100

Anlaufzeit/Ramp-up time (s)

Star

ts/h

2xIe3xIe4xIe5xIe6xIe

MINISTART 11, DAS-T 55

1,00

10,00

100,00

1000,00

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

2xIe3xIe4xIe5xIe6xIe

DAS-T 15

1,00

10,00

100,00

1000,00

1 10 100

Anlaufzeit/Ramp-up time (s)

Star

ts/h

2xIe3xIe4xIe5xIe6xIe

1.27

Page 30: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Dimensioning Rules for Soft Starters

VersiStart II 3 LDS

2xIe

2xIe

3xIe

3xIe

4xIe

5xIe

6xIe

4xIe

5xIe

6xIe

1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

VersiStart II 5,5 / 11 LDS

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe

1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

VersiStart II 7,5 LDS

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe

1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

1.28

Page 31: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Dimensioning Rules for Soft Starters

04/11

VersiStart II 15 LDS

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe

1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

VersiStart II 400-17

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe

1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

VersiStart II 400-25

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe

1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

1.29

Page 32: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Dimensioning Rules for Soft Starters

VersiStart II 400-32

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe

1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

VersiStart II 400-45

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

VersiStart II 400-50

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

1.30

Page 33: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Dimensioning Rules for Soft Starters

04/11

VersiStart II 400-65

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

VersiStart II 400-75

2xIe

2xIe

3xIe

3xIe

4xIe

4xIe

5xIe

5xIe

6xIe

6xIe1

10

100

1000

1 10

Anlaufzeit/Ramp-up time (s)

Star

ts/h

1.31

Page 34: Soft Starters Page - Jomarcaaccording to DIN EN 50160 (IEC 38) 400V r10% 50/60Hz Rated device current 17A 25A 32A 45A Motor rating at 400V mains voltage 7,5kW 11kW 15kW 22kW max. Power

Dimensioning Rules for Soft Starters

Dimensioning of pre-fuses:

Pre-fuses F can be dimensioned according to the following instructions.

Basically, two types of fuse protection are available for the user. 1. Fusing according to allocation type „1“, DIN EN 60947-4-2.

After a short circuit the soft starter is allowed to be inoperative and repair work is possible. 2. Fusing according to allocation type „2“, DIN EN 60947-4-2.

After a short circuit the device must be suitable for further use. However, there is the danger that the contacts of the by-passrelays (-contactors) weld. Therefore, if possible, these contacts are to be checked prior to reconnecting the device to the supply. If this check cannot be carried out by the user, the device has to be returned to the producer in order to have it checked.

The following dimensioning information refers to the below operating conditions: - Use of standard asynchronous motors - Standard ramp-up and/or deceleration times

Fusing according to allocation type „1“:As pre-fuses, we recommend to use line protection fuses (utilization category gL) or automatic circuit-breakers with type K trippingcharacteristic. In the case of automatic circuit-breakers the tripping characteristic of the type series is to be taken into account. With 2x Inthe tripping time should be at least 20s (I1).The fuse values are to be determined by taking the conductor cross-sectional area of the wiring into account. The wiring cross-sectionalarea is to be determined in dependence on the rated motor current, the maximally occurring starting current (normally up to the 5-fold rated device current) and the starting frequency. Table 1 shows the values for numerous applications, i.e., with a 3-fold nominal/ratedcurrent as mean starting current and a maximum ramp-up time of 10s. In the case of parameter values exceeding these values, it may be necessary to adapt the fuse value accordingly. Note! Wiring cross-sectional area according to DIN VDE 0100-430, DIN EN 57100-430.

Fusing according to allocation type „2“:The power semiconductors are to be protected by fuses of the utilization category gR (semiconductor fuses, high-speed fuses). However, since these fuses do not ensure line protection, it is necessary to use additionally line protection fuses (utiliz. category gL). To protect the semiconductors it is necessary to select gR-fuses featuring cutoff-I²t-values which are approx. 10-15% below the I²t-value of the power semiconductor (see technical data). In this connection, the current-value of the selected fuse should not be smaller than the starting current to be expected. PETER electronic does not prescribe the use of semiconductor protection fuses. However, for some UL- or CSA-listed devices there are exceptions which are indicated in the relevant commissioning instructions.

NotesOn the basis of the I²t-value of the power semiconductors, the ramp-up time and possibly the max. starting current, the fuse supplier is able to select a suitable type. Due to the great variety of producers, sizes and types, PETER electronic does not recommend anyparticular fuses.

If the value of the fuse or the cutoff-I²t-value is selected too small, it may happen that the semiconductor fuse reacts during the starting phase or during deceleration.

In the case of special devices having increased ramp-up or deceleration times, the recommended fuse value may have to be adapted.

Table 1 Nominal/rateddevice current(techn. data)

Device type Fuse value

in the case ofallocation type 1

Starting frequency Starts / h

3,5A / 4A DUOSTART, MICROSTART, MINISTART 10A 90

6,5A DUOSTART, MICROSTART, MINISTART VS II 10A 40

60

12A DUOSTART, MINISTART VS II 20A 60

3015A DAS-T, VS II 25A 40 17A VS II 25A 60

25A MINISTART, DAS-T, VS II VS II 35/40A 30

40

32A VS II VS II 50A 20

3045A VSII 63A 10 48A DAS-T 63A 20 50A VS II 100A 35 63A DAS-T 80A 40 65A VS II 125A 25

75A DAS-TVS II

100A125A

4020

88A DAS-T 100A 20 105A DAS-T 125A 20

1.32