SNOWCOOL www.snowcoolsystems.net
SNOWCOOL SYSTEMS INDIA PVT LTD.
PRESENTS
◄ LARGEST RANGE OF AIR-COOLED FAN FLUID COOLERS ►
CAPACITIES ► FLUID FLOW 2 CMH TO 20000 CMH ► HOT FLUID 35°C TO 195°C
CONSTRUCTION ► VERTICAL OR FLAT BED ► MONO OR MULTI CELLS ► MODULAR OR SITE-ERECTED
TYPE ► INDUCED OR FORCED DRAFT ► DRY, ADIABATIC OR HYBRID OPERATION
SNOWCOOL www.snowcoolsystems.net
What is Air-Cooled Fan Fluid Cooler ? Why Fluid Cooling is required ?
A Heat Exchanger is specialized Equipment in which Two Fluids (Hot and Cold) are brought into indirect contact with each other to affect the Transfer of Heat. Fan Fluid Cooler is a Air-Cooled Heat Exchanger that operate on the principle of removing Heat of Fluid flowing in closed-loop Coil and by drawing Fresh Ambient Air over Coil Surface, thus Cooling the Hot Fluid. Since Ambient Air Movement is via Axial Propeller Fan and Cooling Mode is totally Dry, these types of Equipments are popularly known as Fan Fluid Coolers or Fin Fan Coolers or even Dry Cooling Towers. The major Advantages of Fan Fluid Coolers over conventional Evaporative Cooling Towers are No-loss of Cooling Fluid being Closed-loop; vide variety of Fluids including Water, better Control of Cooling, Power & Water Saving, and importantly Maintenance-free Performance being Dry Operation. The biggest Dis-advantage of Fan Fluid Cooler remains that Fluid Temp can’t be bring down below Ambient Air Temp in Dry Mode, unlike in Evaporative Cooling Tower which delivers Water Temp below Ambient Air Temp (nearby its Wet-Bulb Temp). When Fluid Outlet Temp is required below Ambient Air Temp, Adiabatic Fan Fluid Coolers are proposed, wherein incoming Ambient Air is cooled by Adiabatic Mode of Air-Cooling (via Water Spraying or Fogging). When Adiabatically Cooled Ambient Air cools the Fluid, the Fluid Temp comes down with approach to Wet-Bulb Temp of Ambient Air. Hybrid Fan Fluid Coolers or Hybrid Cooling Towers is a Fluid Cooler which uses Dry as well as Adiabatic Mode for Fluid Cooling, thus delivering Constant Temp Cooled Fluid and ensuring optimized consumption of Fan Power and Spray Water. Hybrid Fan Fluid Coolers is considered to be replacement of Evaporative Cooling Towers and bears all Advantages of Dry Coolers.
SNOWCOOL www.snowcoolsystems.net
Fluid (including Water) Cooling is needed for AC & R Plants, Inter-coolers and After-coolers, Engine Jackets, Smelters and Furnaces, Acid Vessels, Production Processes involving Thermic Fluids, Oil Cooling, Condenser Cooling in Power Plants and many more. When Fluid is some Gas or Vapor and is to be condensed (phase change of Fluid), these Fan Coolers are termed as Air-cooled Condensers: and are commonly seen in AC & R Equipments. In Ammonia based Refrigeration Plants, Air-cooled Condensers are supplemented with Evaporative Cooling by Water Spraying hence those are termed as Ammonia Evaporative Condensers. In Power Plants when Steam is to be condensed (as Water) by Air-cooled Coolers, those are termed as Air-cooled Steam Condensers. Based on Construction, Shape and Air Draft Mechanism, Fan Fluid Coolers are catagorised into Forced Draft (for High Temp Fluids, also termed as Air Blast Cooler) and Induced Draft (for Low Temp Fluids and Adiabatic Mode). Further, classification is as Vertical or Flat-Bed, Finned Coils or Finned Tubes and Modular or Site-Erected. At Snowcool’ we are prominent and established player in all types of Fan Fluid Coolers, viz. Fan Fluid Coolers, Fin Fan Coolers, Air Blast Coolers, Vertical Fin Fan Coolers, Flat Bed Fin Fan Coolers, Adiabatic Fan Fluid Coolers, Hybrid Fan Fluid Coolers, Air-Cooled Thermic Fluid Coolers, Air-Cooled Oil Coolers, Dry Cooling Towers, Evaporative Condensers, Air-cooled Condensers, Air-cooled Steam Condensers and many more. .
SNOWCOOL www.snowcoolsystems.net
How Fan Fluid Cooler works ? How to select Fan Fluid Cooler ?
FACTORS TO BE CONSIDERED FOR SELECTING FAN FLUID COOLERS : APPLICATION (CONDENSOR COOLING / UTILITY / ENGINE / PROCESS) FLUID FLOW (CMH / LPH / GPM / KGPH) HOT FLUID INLET (°C / °F) COLD FLUID OUTLET (°C / °F) ATMOSPHERIC AIR CONDITIONS, DRY BULB TEMP (°C / °F) & RH (%) FLUID TYPE (INDUSTRIAL WATER / DM WATER / OIL / THERMIC FLUID) WATER AVAILABILTY (FOR ADIABATIC OR HYBRID MODE) POWER AVAILABILITY (MECHANICAL DRAUGHT / WATER PUMPING) SPACE AVAILABILITY (AREA / INSTALLATION LOCATION) COST BUDGETS (CAPITAL COST / MAINTENANCE COST / LIFE) SERVICEABILITY (REPAIRS / REPLACEMENT / SKILLS) EFFICIENCY (WATER & POWER CONSUMPTION / FLUID PR DROP)
SNOWCOOL www.snowcoolsystems.net
SNOWCOOL’ LARGEST RANGE OF AIR-COOLED FAN FLUID COOLERS
TYPE COOLING APPLICATION MIN - MAX
FLUID OUTLET TEMP (⁰C)
VERTICAL FIN FAN COOLER CONDENSOR WATER 32 - 38
VERTICAL FAN FLUID COOLER PROCESS FLUID / WATER 38 - 55
FLAT BED FIN FAN COOLER PROCESS FLUID / WATER 32 - 38
FLAT BED FAN FLUID COOLER PROCESS FLUID / UTILITY WATER 38 - 55
AIR BLAST FLUID COOLER THERMIC FLUID / OIL 55 - 180
VERTICAL ADIABATIC FIN FAN COOLER CONDENSOR / UTILITY WATER 28 - 32
FLAT BED ADIABATIC FAN FLUID COOLER CONDENSOR / UTILITY WATER 28 - 32
FLAT BED HYBRID FAN FLUID COOLER CONDENSOR / UTILITY WATER 28 - 35
SNOWCOOL www.snowcoolsystems.net
FLUID FAN COOLERS - TYPES & APPLICATIONS
VERTICAL V-STYLE FIN FAN FLUID COOLER
FOR STANDARD, CLEAN ATMOSPHERE
DRY MODE OF OPERATION
FLAT BED FIN FAN FLUID COOLER
FOR STANDARD, CLEAN ATMOSPHERE
DRY MODE OF OPERATION
VERTICAL V-STYLE FIN FAN FLUID COOLER
FOR STANDARD, CLEAN ATMOSPHERE
DRY & ADIABATIC MODE OF OPERATION
FLAT BED FLUID FAN COOLER
FOR INDUSTRIAL, CORROSIVE & DUSTY ATMOSPHERE
DRY & ADIABATIC MODE OF APPLICATION
SNOWCOOL www.snowcoolsystems.net
FLUID FAN COOLERS - COIL CONSTRUCTION
ALUMINIUM FINNED COPPER TUBE COIL
FOR STANDARD, CLEAN ATMOSPHERE
DRY MODE OF APPLICATION
SS FINNED SS TUBE COIL
FOR COASTAL & CORROSIVE ATMOSPHERE
DRY & ADIABATIC MODE OF APPLICATION
SS PLAIN TUBE COIL
FOR INDUSTRIAL, CORROSIVE & DUSTY ATMOSPHERE
ADIABATIC MODE OF APPLICATION
INTEGRALLY FINNED SS TUBE COIL
FOR INDUSTRIAL, COASTAL & CORROSIVE ATMOSPHERE
DRY & ADIABATIC MODE OF APPLICATION
SNOWCOOL www.snowcoolsystems.net
FLUID FAN COOLERS – FANS
COMPACT AXIAL FANS
INDUCED DRAFT, FIXED ALUMINIUM BLADES
MULTIPLE FANS PER CELL
PROPELLER TYPE AXIAL FAN
INDUCED DRAFT, ADJUSTABLE ANGLE FRP BLADES
DIRECT DRIVEN, SINGLE FAN PER CELL
PROPELLER TYPE AXIAL FAN
FORCED DRAFT, ADJUSTABLE ANGLE AL-ALLOY BLADES
DIRECT DRIVEN, TWO FAN PER CELL
AEROFOIL TYPE AXIAL FAN
INDUCED DRAFT, ADJUSTABLE ANGLE FRP BLADES
DIRECT DRIVEN, ONE FAN PER CELL
SNOWCOOL www.snowcoolsystems.net
FLUID FAN COOLERS – ACCESSORIES
ADIABATIC SPRAY SYSTEM
SOLENOID CONTROLLED MULTIPLE SPRAY CIRCUITS
SPRAY CONTROL IN RESPONSE TO AMBIENT AIR TEMP
WATER SPRAY BOOSTING PUMPS
VERIABLE SPEED PUMPING, CONSTANT PRESSURE
DEDICATED CONTROLLER, SKID MOUNTED MODULE
INTELLEGENT MCC PANELS
CENTRILISED MONITORING, BMS & DCS COMPATIBILITY
HIGHEST ON SAFETY & RELIABILITY
FAN VARIABLE SPEED CONTROLLERS
COOLER MOUNTED, RAIN-DUST PROOF PANELS
PRESSURE BOOSTING FOR ADIABATIC SPRAYS
SNOWCOOL www.snowcoolsystems.net
FLUID FAN COOLERS – INTEGRATED PROJECT SOLUTIONS
FLUID COOLING INTEGRATED PROJECT COMPRISING OF ADIABATIC FAN FLUID COOLERS, SPRAY BOOSTER PUMPS,
INTELLIGENT MCC PANEL, DCS CONNECTIVITY, ELECTRICAL SYSTEM AND MANY MORE……ONE STOP PROJECT SOLUTION
SNOWCOOL www.snowcoolsystems.net
Thank you
Visit our Website to know more about us
Write us for Customised Solution
E-mail : [email protected]
SNOWCOOL SYSTEMS INDIA (P) LTD.
Marketing Head Office 20, Asiatic Arcade, Pokhran Road No 1, Vartak Nagar, Thane (W) – 400606, (Mumbai) India
Tel / Fax : 91-22- 41237770, 41237771
Sales Offices / Representatives in All Major Cities across India, please Visit our Website for Contact Details