22
1 RV25….250 X X X X X X X / X X / / / X X X X 3 RK275....800 X X X X X X / X X / / / X X X X X 4 RK3.5….7, RMS400-800 X X X X X X / X X / / / X X X X X 5 RKC100….500 X X X X X X / X X / / / X X X X X 6 RKM200 X X X X / X / X X / / / / X X X RKM300,RKM400 7 RKM100,RKM250 X X X X X X X / X X / / / X X X X RMS400-800 8 RR50 X X X X X X X / X X / / / / X X X 9 RMB-V-50..100 X X X X / X / X X / / / / X X X 10 RKM060 X X X X X X X X X X X X / / X X X 11 RMH 060, 0250 X X X X X / X X X X / / / / X X 12 RKM 0250, 050 X X / X X X / / X X X X 13 RPP / / / / / X / X 14 RTH45 X X X X X / X X X X X / / X X X - USABLE / - PLEASE ASK BEFORE SELECTING NOTE : POLLUTION TYPE POLLN. LEVEL COARSE > 1MM 30-40% MEDIUM 0.5 TO 1 MM 20% FEW < 0.5 10-20% RECOMMENDATION CHART SNo SERIES APPLICATION MEDIUM POLLUTION IMPELLER TYPE SEMI OPEN CLOSED SHEET METAL FABRICATED. PERIPHERAL CASTED 2 BORING SAWING MILLING TURNING GRINDING CIRCULATING WASHING EMULSIONS COOLANT & LBRCTS WATER DE IONISED WATER SOLVENTS CHEMICALS COARSE MEDIUM FEW HIGH TEMPERATURE CHILING COOLANT PUMPS R C M Y K

SNo SERIES APPLICATION MEDIUM POLLUTION IMPELLER TYPErajamane.com/downloads/Layout-2007.pdf · 5 Power in kW 1.7 2 2.25 3 3.7 Current in A 3.5 4 4.5 6 8 in kW 4 4.3 5.5 7.5 8.5 9

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

1 RV25….250 X X X X X X X / X X / / / X X X X

3 RK275....800 X X X X X X / X X / / / X X X X X

4 RK3.5….7, RMS400-800 X X X X X X / X X / / / X X X X X

5 RKC100….500 X X X X X X / X X / / / X X X X X

6 RKM200 X X X X / X / X X / / / / X X XRKM300,RKM400

7 RKM100,RKM250 X X X X X X X / X X / / / X X X XRMS400-800

8 RR50 X X X X X X X / X X / / / / X X X

9 RMB-V-50..100 X X X X / X / X X / / / / X X X

10 RKM060 X X X X X X X X X X X X / / X X X

11 RMH 060, 0250 X X X X X / X X X X / / / / X X

12 RKM 0250, 050 X X / X X X / / X X X X

13 RPP / / / / / X / X

14 RTH45 X X X X X / X X X X X / / X X

X - USABLE / - PLEASE ASK BEFORE SELECTING

NOTE : POLLUTION TYPE POLLN. LEVEL

COARSE > 1MM 30-40%

MEDIUM 0.5 TO 1 MM 20%

FEW < 0.5 10-20%

RECOMMENDATION CHART

SNo SERIES APPLICATION MEDIUM POLLUTION IMPELLER TYPE

SEM

I O

PEN

CL

OSE

D

SHEE

T M

ETA

LFA

BRIC

ATE

D.

PE

RIP

HE

RA

L

CA

STE

D

2

BO

RIN

G

SAW

ING

MIL

LIN

G

TU

RN

ING

GR

IND

ING

CIR

CU

LA

TIN

G

WA

SHIN

G

EM

UL

SIO

NS

CO

OLA

NT

& L

BRC

TS

WA

TER

DE

ION

ISED

WA

TER

SOLV

ENTS

CH

EM

ICA

LS

CO

AR

SE

ME

DIU

M

FEW

HIG

H

TE

MP

ER

AT

UR

E

CH

ILIN

G

COOLANT PUMPS

R

C M Y K

CATALOG INDEX

PAGE SALIENT FEATURES

NO.IN MODEL/SERIES (FOR DETAILED SELECTION CHART REFER

CAT. Technical Information RECOMMENDATION CHART)

4 –5

6 RV25.... RV250RKC & RSM

7 RK275....800

8 RK3.5......RK7RKC & RSM

9 RPP

10 RMB-V

11 RR50

12 RKM0250RKM050

13 RMH0250

14 RKM060

15 RTH45

16 RMH060

17 RKM100

18 RKM200 & 300

19 RKM250

20 RMS400....800

21 ROS

22 RSB

23 –

24 BRINKMANNPUMPS

TECHNICAL INFORMTION

SINGLE STAGE COOLANT PUMPS FOR CONVENTIONAL MACHINES, HIGHLYEFFICIENT, UPTO 1 MTR. IMMERSION DEPTH

SINGLE STAGE, HIGH FLOW COOLANT PUMP, FOR GRINDING MACHINES,FILTRATION SYSTEMS.

BOTTOM OUTLET, SINGLE STAGE & COUPLED TYPE PUMPS FOR FILTRATIONAPPLICATION.

ALL POLY-PROPELENE PUMPS FOR SPECIAL APPLICATION

TANK TOP MOUNTING TYPE, IMPORT SUBSTITUTE PUMPS FOR CNC MACHINES.

COMPACT, LOW IMMENSION, HIGH PRESSURE PUMPS FOR CNC LATHES,TEMPERATURE CONTROL EQUIPMENTS

MULTISTAGE, COMPACT PUMPS FOR CLEAN LIQUIDS FOR WATER, COOLANTEMULSIONS

HORIZONTAL PUMPS, FOR SPECIAL APPLICATIONS.

ALL STAINLESS STEEL PUMP PARTS, EFFICIENT PUMPS FOR CNC HIGH PRESSUREAPPLICATIONS.

BRINKMANN PUMPS, GERMANY PUMP PORTION, COUPLED WITH RAJAMANEMOTORS FOR HIGH PRESSURE APPLICATIONS.

HORIZONTAL, ALL STAINLESS STEEL PUMP PARTS FOR SPECIAL APPLICATIONS.

MOST POPULAR, MEDIUM PRESSURE PUMPS FOR ALL CNC TURNING CENTRES &MACHINING CENTRES

MULTISTAGE PUMPS FOR MACHINING CENTRES

MOST RUGGED, MULTISTAGE PUMPS WITH HIGHER CONTAMINATIONHANDLING CAPACITY.

MULTISTAGE, HIGH PRESSURE & HIGH FLOW PUMPS FOR COOLANTS WITHCONTAMINATION.

OIL SKIMMENS FOR REMOVAL OF FLOATING OIL FROM COOLANT TANKS.

STIRRERS, IN COMPACT SIZES FOR CHILLED UNITS, FOR USE IN COOLANTTANKS AND SIMILAR APPLICATIONS.

GENERAL INFORMATION ON OUR OTHER PRODUCTS.

SPECIAL BRINKMANN PUMPS FOR MACHINE TOOLS INDUSTRY.

3

COOLANT PUMPS

R

Technical Information

I. ELECTRICAL:

1. Always connect the 3 phase coolant pumps through suitable OLR or MPCB to avoid motor failures due tooverloading, voltage fluctuations, single phasing , etc.

2. All standard coolant pumps are fitted with Induction motors having specifications as- 415V,50Hz, 3 Phase, S1 duty,Cl. B. ,2800 RPM. The power rating is given against the pump model. Other voltage & frequency are available onrequest.

3. Self cooling motors (TESC) are fitted for coolant pumps with upto 0.18kW rating. These motor body temperatureraise have been tested & are within the range specified in class of insulation section. The body temperature of thesemotors will be within 80O C even when felt very hot by bare hand.

4. Temperature raise: All motor temperature raise is as under, based on its class of insulation, in addition to theambient temperature (room temperature):

5. OLR/MPCB setting: set the current in these at 10% higher than that on the nameplate, to avaoid nuisance trippingcaused by variation in loads, voltages, supply frequency, etc. the motors are capable of taking this extra current.

6. Frequency Drive: Most of the motors are suitable for operating through frequency drive, from 0-50 Hz. Foroverloading with 60 Hz. ask factory.

7. Connection diagrams:

Class of Insulation Temperature Raise

B 80o C

F 120o C

FOR LOW SPEED: SUPPLY A2B2C2OPEN A1B1C1

FOR HIGH SPEED: SUPPLY A1B1C1 SHORT A2B2C2

FOR LOW VOLTG: SHORT A1C2,B1A2,C1B2SUPPLY A2,B2,C2

FOR HIGH VOLTG.:SHORT A1B1C1 SUPPLY A2B2C2

SupplyTO CHANGE THE DIRECTION

OF ROTATION INTERCHANGE

ANY TWO SUPPLY LEADS.

Standard 3 leads, for direct online start

U V W

LOW VOLTAGE

HIGH VOLTAGE

or

(colour coded)

Dual voltage connection :

Star-delta connection-for 5.5kw & above:

(For D.O.L. starting connect in delta. For through starter, remove shorting leads.)

U 1 V1 W1U 1 V1 W1

W2 U 2 V1

For star/delta starter

4

Dual speed-dhahlender winding:

For Direct online start

Single phase Motor :SUPPLY

A1M1 A 2CAP

M2

For changing the direction, interchangeM1 & M2

A 1 B1 C1

C2 A 2 B2

A 1 B1 C1

A 2 B2 C2

COOLANT PUMPS

R

8. Current rating: the current ratings of the pump motors, against their kW is given below. This table is for 2 pole(2800RPM) motors only. If the pump is fitted with special motor of other RPM, call factory for current details:

Powerin kW

0.08

0.1

0.18

0.25

0.37

Currentin A

0.24

0.34

0.4

0.75

0.9

Powerin kW

0.54

0.75

1.1

1.3

1.5

Currentin A

1.5

1.8

2.6

2.9

3.4

II. MECHANICAL/ HYDRAULIC:

1. Coolant pump performance graphs shown in the catalog are for water as media, at room temperature only. Pumpperformance varies +/- 15% on the flowrate & +/-10% on the head.

2. For best performance of the pumps, maintain minimum & maximum levels as given in the catalog.

3. For multistage coolant pumps, while mounting on the small immersion tanks, ensure that the minimum of twoimpeller stages are immersed in the liquid. Balance portion of the pump can be mounted on a spacer like distancepiece.

4. Suction gap: Maintain minimum suction gap depending on the flow rate being taken- 25 mm for upto 200 LPM flow& 50 mm for upto 800 LPM flow.

5. Effect of Viscocity & Specific Gravity of liquids: The raising viscocity needs more power. As such the standardmotors can be used for liquids having 5 CST viscocity & coolant emulsions. Similarly, the raising specific gravityneeds more power. This power requirement is linearly proportional to the specific gravity of the liquid. e.g. if 1 kwis required for water, 1.2 kw is recommended for 1.2 specific gravity liquid.

5

Powerin kW

1.7

2

2.25

3

3.7

Currentin A

3.5

4

4.5

6

8

Powerin kW

4

4.3

5.5

7.5

8.5

Currentin A

9

9.5

10.5

14

16

10. Pressure Boosting Arrangement: The following diagram shows, how anexisting multistage pump can be connected to a Booster pump to enhancethe pressure.

8. On/off cycles: The standard pumps upto 6 stages are suitable for 40 on/off per hours. Above 6 stages pumps aresuitable for 30 on/off per hour. For higher on/off per hour applications, call factory.

9. Pipe fittings: Use always standard G.I. fittings having good radius at bends & elbows to avoid head losses. Do not fitan elbow or reducer nipple immediately at the pump outlet. Take the same pipe as the outlet is as far as possible, toget the best flow/pressure at the end point of piping.

3 O’CLOCK

9 O’CLOCK

12 O’CLOCK

Terminal Box

Outlet

6 O’ CLOCK6. Terminal box position w.r.t outlet: The standard options are given below6 O’ clock is the standard position maintained in factory. For any change,mention while ordering the pump.

7. For grinding or similar application involving abbrassive dust in the coolant:It is recommended to use pumps without bush bearings for such applications.In case of pumps having bush bearings or mechanical seals (see the standardspares list in each page) they have to be ordered with carbide materials.

11. Side suction pumps for outside tank mounting: These pumps are availablefor series RKM0250, RKM050 ,RKM200, RKM300 & RKM060, apart fromHorizontal mounting RMH pumps. The schematic diagram is as under.For detailed mounting ask factory.

12. Spares Ordering: While ordering spares or pumps, give the full modelor frame name along with the sl. No. on the nameplate. Give anyextensions given after frame / model like X,Y,XZ,etc. These indicatesthe speciality of the product & helps in providing the correct spare orproduct.

EXISTING PUMP BOOSTER PUMP

COOLANT PUMPS

R

SIZE TYPEImmersion H1 H2 A+0 B D d d1 E F L1 L2 L3 Flow at Max Hd Wt Old

Depth MAX MAX -1 MAX MAX -0.2 BSP -0 MAX 2mtr hd ± 10% Kw in Kg ModelH ± 15% Type

RV25# 25/120 120 30 160 100 72 105 115 R3/4” 30 130 130 155 70 25 4 0.08 525/170 170 80 5.5

RV40 40/120 120 30 160 100 72 105 115 R3/4” 30 130 130 155 70 40 5 0.1 5 RK140/170 170 80 5.540/220 220 130 640/270 270 180 6.540/350 350 260 7.3

RV63 63/120 120 30 190 100 72 105 115 R3/4” 30 130 130 155 70 63 6 0.18 1263/170 180 80 1363/220 230 130 14

RK80^ 80/220 220 150 175 140 72 110 160 R1” 30 180 95 120 93 80 7 0.18 1280/270 270 200 13

RV100 100/220 220 130 205 140 72 140 160 R1” 32 180 150 175 100 100 8 0.25 19 RK2100/270 270 180 21

RV160 160/170 170 80 235 140 72 140 160 R1” 32 180 150 175 100 160 10 0.37 19 RK3160/220 220 130 20160/270 270 180 21160/350+ 350 260 25

RV250 250/170 170 80 260 140 72 140 160 R11/4” 32 180 150 175 100 250 13 0.54 21 RK200250/220 220 130 22250/270 270 180 23250/350+ 350 260 25250/440+ 440 350 28

RV Series as per IS:2161 # Equivalent to other manufacturers Type 1 ^ Not as per IS:2161, Equivalent to other manufacturers Type2 + H2 Max is 50mm Extra – RV25-RV160 available for single phase 230V 50Hz. – Tank, pipeset available in standard sizes.

HE

AD

IN

ME

TR

ES

DISCHARGE IN LPM

6

CONVENTIONAL & MONOBLOCK COOLANT PUMP RV25…RV250

CONSTRUCTION

Body ALStem C.I.Impeller Velox553/ALImpeller Cover Velox553/CIShaft EN8

OPTIONS

Stem Gunmetal/S.S.Impeller Gunmetal/CI/S.S.Impeller Cover Gunmetal

Shaft Teflon Coated/S.S.410

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

Kinematical Viscocity - 90mm2/sPumping Temperature - 0-600CSPECIAL VERSIONS

Avilable* ON/OFF Rotary switch* With flame proof motor for hazardous liquids* For Frequent ON/OFF Cycles * For Any Immersion depth* For high viscous liquids * To handle Hot Liquids upto 100 C

USED ON

All lathes, Milling, CNC, retrofittings, EDMwire and other conventional machines,Cutting Machines, Printing machines Etc

COOLANT PUMPS

R

7

* ALL PUMPS - RV25....RV250, RK80, RK275...RK800-WITH STD. IMMERSION DEPTH ARE GLANDLESS. THEY CANRUN DRY & WILL NOT HAVE AIR LOCKING PROBLEM.

• STANDARD SPARES: IMPELLER FOR LONG IMMERSION PUMPS, ABOVE 350MM, BUSH/SLEEVE.

TYPE Immersion H1 H2 A+0 B D d d1 E F L1 L3 Kw WtDepth H Max Max -1 Max Max -0.2 BSP -0.2 Max in Kg

RK275 300 220 310 200 82 156 225 1 ½” 42 250 126 125 0.75 30RK300 300 220 310 200 82 156 225 1 ½” 42 250 126 126 1.1 30

RK400 300 220 375 200 82 175 225 1 ½” 42 250 150 126 1.5 34

RK600 300 220 430 200 82 200 225 2” 42 250 165 126 2.25 42

RK800 300 220 465 200 82 230 225 2” 42 250 180 126 3.75 51

CONVENTIONAL & MONOBLOCK COOLANT PUMPS RK275...800

CONSTRUCTION

Body C.I./ALStem C.I.Impeller C.I.Impeller Cover C.I.Shaft EN8

OPTIONS

Stem Gunmetal/S.S.Impeller Gunmetal/S.S.Impeller Cover Gunmetal

Shaft Teflon Coated/S.S.410

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

Kinematical Viscocity - 90mm2/sPumping Temperature - 0-800C

SPECIAL VERSIONS

Avilable* For Any Immersion depth* For high viscous liquids * To handle Hot Liquids upto 100 C

USED ON

All lathes, Milling, CNC, retrofittings, EDMwire.Cutting Machines, Printing machines Etc

HE

AD

IN

ME

TR

ES

DISCHARGE IN LPM

COOLANT PUMPS

R

A+0 B D d d1 S F L1 INLET L3 POWER IN Wt

COUPLED NON SUCTION DEPTH MAX COUPLED NON -1 MAX MAX -0.2 BSP MAX BSP KW / HP in Kg

COUPLED H COUPLED Inch

RKC-100 RK 3.5/311 RSM 3.5 311 200 420 236 141 82 156 165 1" 12 200 126 1½" 120 0.75/1.0 28

RKC-150 RK 4/311 RSM 4 311 200 420 236 141 82 156 165 1" 12 200 126 1½" 120 1.1/1.5 30

RKC-200 RK 5/311 RSM 5 311 200 454 280 141 82 170 165 1¼" 12 200 135 1½" 120 1.5/2.0 39

RKC-300 RK 6/311 311 200 500 310 181 82 208 215 1½" 15 250 155 1½" 125 2.25/3.0 50

RKC-500 RK 7/311 311 200 590 430 181 82 225 215 2" 15 250 165 2½" 125 3.75/5.0 60

HIGH DISCHARGE PUMP (FLOODING TYPE) RK3.5 TO RK7 & COUPLED RKC SERIES

CONSTRUCTION

Body C.I.Stem C.I.Pump Housing C.I.Impeller C.I.Shaft EN8Flange C.I.Bush/sleeve GM/EN9

OPTIONS

Stem GunmetalPump Housing GunmetalImpeller GunmetalShaft Stainless SteelBush/sleeve Carbide/Carbide

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

Kinematical Viscocity - 90mm2/sPumping Temperature - 0-800C

SPECIAL VERSIONS

Avilable• With Flame Proof Motors to pump hazardous liquids• For frequent on/off cycles • For any immersion depths• For high viscous liquids • To handle hot liquids up 1000C• With below shown mounting (give A&B dimensions)

USED ON

All CNC machines to flush chips, to transferfluid for Filteration, Cyclone Filter, ChipConveyors, EDM Wire cut machines, Heattreatment plants, Grinding machnes, Graniteand Indoor Fountains.

SERVICE AND SPARES AVAILABLE THROUGH OUR COUNTRY WIDE DEALERS NETWORKASK US FOR MORE DETAILS

* STANDARD SPARES : IMPELLER, BUSH & SLEEVE.

RK3.5 TORK7

A (OptionalMounting)

RKC100 TO 500

A (OptionalMounting)

B

8

RSM

TYPE SIDE IMMERSION H1 H2 MAX

COOLANT PUMPS

R

9

DISCHARGE IN LPM

RAJAMANE RPP - ALL POLYPROPELENE PUMPS

ASK for Moredetails

RPP160 IN VERTICLEIMMERSSION TYPE.ALL WET ENDS INPOLY-PROPELENE

RPP5-IN HORIZONTAL MOUNTING.ALL WET PARTS IN POLY-PROPELENE.

Flow : 400 LPM Max Head : 30 MTR. Max in both version

COOLANT PUMPS

R

VERTICAL FOOT MOUNTED RMB-V SERIES

CONSTRUCTION

Body C.I./AL.Stem C.I.Impeller AL.Impeller Cover C.I.Shaft EN8Mechanical seal Carbon/Ceramic

OPTIONS

Stem GunmetalImpeller C.I./GunmetalImpeller Cover GunmetalShaft S.S.Mechanical seal Carbide/Carbide

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

Kinematical Viscocity - 90mm2/sPumping Temperature - 0-500CThe liquid media should be prefiltered formoderete contamination. (0.5-1 mm, 20%).

SPECIAL VERSIONS

Avilable• With flame proof motor for hazardous liquids.

USED ON

All CNC machines, lathes, and machining centres.

NOTE :

1. THE ABOVE SHOWN PERFORMANCE CURVE IS FOR WATER , WITHOUT NON-RETURN VALVE & WATER LEVEL300 MM BELOW THE PUMP SUCTION. PUMP DELIVERS HIGHER DISCHARGE WHEN CONNECTED AT TANKLEVEL (20-30% MORE), AND REDUCES AS THE WATER LEVEL DROPS.

2. THE PUMP CAN PRIME, FOLLOWING INITIAL PRIMING, UPTO 400 MM. FOR HIGHER DEPTHS UPTO 600 MMA NON-RETURN VALVE IS TO BE USED AT THE DELIVERY SIDE. USE OF NON RETURN VALVE CAUSES A DROPOF 10% IN THE PERFORMANCE.

3. THE SUCTION LINE MUST BE AIR TIGHT, AND AVOID THE USE OF FOOT VALVE.

• STANDARD SPARES : IMPELLER, MECHANICAL SEAL AND GASKET (SEALING) SET.

HE

AD

IN

ME

TR

ES

DISCHARGE IN LPM

10

TYPE H D d1 d2 d E A DISCHARGE HEAD Kw Wt.(LPM) (M) Kg.

RMV-V-50 300 145 3/4" 3/4" 160 80 160 50 2 0.25 14

RMB-V-100 330 145 1" 1" 160 110 180 100 2 0.37 16

COOLANT PUMPS

R

HIGH PRESSURE - LOW IMMERSION RR50 SERIES

CONSTRUCTION

Body C.I./A.L.Stem C.I.Impeller BronzeImpeller Cover C.I.Shaft EN8Bush Bearing GM

OPTIONS

Stem GunmetalImpeller Cover GunmetalShaft S.S.410Bush Bearing Carbon

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

Kinematical Viscocity - 90mm2/sPumping Temperature - 0-800CClear Media - Prefiltered

(50 microns)SPECIAL VERSIONS

Avilable• With flame proof motor for hazardous liquids• With dual speed motor• Special versions to handle hot liquids upto 2000C

USED ON

All CNC machines, lathes, and machiningcentres. Most suited for through tool cooling,deep hole drilling, chilling units and industrialwashing machine, spindle cooling, temperaturecontrol.

TYPE IMMERSION H1 H2 A+0 B D d d1 E F L1 L3 Kw WtDEPTH (H) MAX MAX -1 MAX MAX -0.2 BSP -0.2 MAX in Kg

RR50 LP 140 100190 150240 200 275 100 82 156 115 3/4" 30 130 115 120 0.54 20320 280370 330

RR50 HP 140 100190 150240 200 300 100 82 156 115 3/4" 30 130 126 120 0.75 24320 280370 330

RR50-2 160 130210 180260 230 350 100 82 170 115 3/4" 30 130 135 120 1.5 30350 300390 360

RR25 150 110 255 100 82 140 115 3/4" 32 130 115 70 0.54 15

• STANDARD SPARES : IMPELLER, BUSH & SLEEVE AND SPACERS

HE

AD

IN

ME

TR

ES

DISCHARGE IN LPM

11

COOLANT PUMPS

R

HE

AD

IN

ME

TR

ES

DISCHARGE IN LPM

12

• STANDARD SPARES : IMPELLER COVER, IMPELLER, MECHANICAL SEAL

TYPE NO OF IMMERSION H1 H2 A+0 B D d d1 S F L1 L2 Kw WtSTAGES DEPTH (H) MAX MAX -1 MAX MAX -0.2 BSP MAX in Kg

RKM02505 5 195 140 215 100 72 140 115 3/4" 7 130 105 70 0.37 15RKM02510 10 315 260 320 100 82 156 115 3/4" 7 130 126 70 0.75 22RKM02515 15 435 380 360 100 82 170 115 3/4" 7 130 135 70 1.5 30RKM054 4 220 170 300 100 72 140 115 3/4" 7 130 105 70 0.54 16RKM058 8 360 290 320 100 82 156 115 3/4" 7 130 126 70 0.75 22

RKM0512 12 495 415 360 100 82 170 115 3/4" 7 130 135 70 1.5 30

MULTISTAGE COOLANT PUMPS RKM025 & RKM050

CONSTRUCTION

Body C.I./AL.Stem C.I.Impeller NorylImpeller Cover Nory1Shaft SS410Mechanical Seal Carbon/Ceramic

OPTIONS

Stem Gunmetal / SSShaft S.S.Mechanical Seal SiC/SiCImpeller SS316Impeller Cover SS316

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

Kinematical Viscocity - 5 CST maxPumping Temperature - 0-500C

SPECIAL VERSIONS

Avilable• With Flame Proof Motors to pump hazardous liquids• With dual speed motor• With full water proof construction to pump demineralised /

deionised water• Horizontal & Vertical foot moonted

USED ON

Most suited for chilling units, EDM wire cut,spark erosion machines, small CNC lathes andmachining centres etc.

COOLANT PUMPS

R

13

MULTISTAGE HORIZONTAL COOLANT PUMP RMH 0250 SERIES

CONSTRUCTION

Motor body ALSuction cover C.I.Impeller NorylDelivery cover C.I.Impeller Cover NorylShaft SS410

OPTIONS

Suction cover S.S/Brass/GunmetalDelivery cover S.S/Brass/Gunmetal

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

With spl. Constn. - Light Chemicals- Washing solutions

Kinematical Viscocity - 1 CST (Max.10CST)Pumping Temperature - 0 – 500C

SPECIAL VERSIONS

Avilable• With flame proof motor for hazardous liquids

USED ON

All CNC machines, lathes, and machining centres.Most suited for washing machines, Electrochemicaldeburring machine, drilling, chilling units,Descaling, etc.

DISCHARGE IN LPM

(Dimension A & B are mounting holes for the pump/ SUCTION & DELIVERY is 3/4”BSP, female threading)# - also available with 1 PHASE 230V, 50HZ., CAPACITOR START/RUN MOTOR.

• STANDARD SPARES : IMPELLER, BUSH & SLEEVE, MECHANICAL SEAL, O-RINGS AND SPACERS

TYPE A B H1 H2 D L1 L MOUNTING POWER dischargeHOLE DIA (KW/HP)

RMH 02503 80 100 63 140 114 146 355 7 0.18/0.25 #

RMH 02504 90 112 71 170 144 169 380 7 0.25/0.33 #

RMH 02505 90 112 71 170 144 192 405 7 0.37/0.5 #

DIMENSIONAL DETAILS

REF

ERG

RA

PH

HEA

D

IN

MT

RS

3/4” BSP

3/4” BSP

COOLANT PUMPS

R

MULTISTAGE COOLANT PUMP RKM 060 SERIES

CONSTRUCTION

Body C.I.Stem C.I.Impeller SS316Impeller Cover SS316Shaft SS316Mechanical Seal Carbon/Ceramic

OPTIONS

Stem Gunmetal/AL./SSMechanical Seal SiC/SiC

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

Kinematical Viscocity - 90mm2/sPumping Temperature - 0-800C

SPECIAL VERSIONS

Avilable• With flame proof motor for hazardous liquids• With dual speed motor / frequency drive.• Pressure booster pumps, to increase the pressure. (See page 10)• Side suction arrangement – see technical information sheet 4 & 5

USED ON

All CNC machines, lathes, and machining centres.Most suited for through tool cooling, deep holedrilling, chilling units, EDM wire cut machinesand industrial washing machine.

• STANDARD SPARES : IMPELLER, SLEEVE, IMPELLER COVER WITH BUSH, MECHANICAL SEAL AND SPACERS

SPECIAL FEATURES

All SS pump construction with sheetmetal technology, light weight, wideapplication, efficient, elegant inappearance, long trouble free seals &bushes, double sealing stem.

TYPE IMMERSION H1 H2 A+0 B D d d1 E F L1 L3 Kw WtDEPTH (H) MAX MAX -1 MAX MAX -0.2 BSP -0.2 MAX in Kg

RKM0604 190 110 320 140 82 140 165 1" 48 180 105 96 0.54 16.0RKM0606 240 150 370 140 82 156 165 1" 48 180 126 96 0.75 19.0RKM0608 290 200 370 140 82 156 165 1" 48 180 126 96 1.10 20.0RKM0612 390 300 410 140 82 170 165 1" 48 180 135 96 1.50 23.0RKM0616 490 400 410 140 82 170 165 1" 48 180 135 96 2.25 25.0RKM0620 590 500 455 140 82 206 165 1" 48 180 155 96 3.00 32.0

HE

AD

IN

ME

TR

ES

DISCHARGE IN LPM

14

COOLANT PUMPS

R

15

RAJAMANE-BRINKMANN RTH 45 SERIES HIGH PRESSURE PUMP

CONSTRUCTION

Motor body C.I.Stem C.I.Impeller S.S. 316Impeller cover S.S. 316Mechanical Seal SiC/SiCShaft S.S. 316

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

With spl. Constn. - Light Chemicals- Washing solutions

Kinematical Viscocity - 1 CST (Max.10CST)Pumping Temperature - 0 – 800C

SPECIAL VERSIONS

• With frequency driveUSED ON

All CNC machines, lathes, and machining centres.Most suited for through tool cooling, deep holedrilling, chilling units and industrial washingmachine Temperature controlling units, etc.

OPTIONS

Stem Bronze

TECHNICAL SPECIFICATIONS:

TH45/690 3.3 kW / 2880 RPM TH45/540 2.25 kW/2880 RPM

30 LPM @ 222 MTR.s 30 LPM @ 165 MTR.S

1.0 kW / 1440 RPM 0.67kW/ 1440 RPM

30LPM @ 40 MTR.S 30LPM @ 25 MTR.S

• STANDARD SPARES : IMPELLER, SLEEVE, IMPELLER COVER WITH BUSH, MECHANICAL SEAL AND SPACERS

160 100

100

dia.139

690

540

425

dia. 190

3/4” BSC

COOLANT PUMPS

R

MULTISTAGE HORIZONTAL COOLANT PUMP RMH 060 SERIES

CONSTRUCTION

Motor body C.I/ALSuction cover C.I.Impeller SS316Delivery cover C.I.Impeller Cover SS316Shaft SS410Mechanical seal Carbon/Ceramic

OPTIONS

Suction cover S.S/Brass/GunmetalDelivery cover S.S/Brass/GunmetalMechanical seal SiC/SiC

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

With spl. Constn. - Light Chemicals- Washing solutions

Kinematical Viscocity - 1 CST (Max.10CST)Pumping Temperature - 0 – 800C

SPECIAL VERSIONS

Avilable• With flame proof motor for hazardous liquids

USED ON

All CNC machines, lathes, and machining centres.Most suited for washing machines, Electrochemicaldeburring machine, drilling, chilling units,Descaling, etc.

DISCHARGE IN LPM

(Dimension A & B are mounting holes for the pump/ SUCTION & DELIVERY of 1”BSP, female threading)# - also available with 1 PHASE 230V, 50HZ., CAPACITOR START/RUN MOTOR.

• STANDARD SPARES : IMPELLER, BUSH & SLEEVE, MECHANICAL SEAL, O-RINGS AND SPACERS

TYPE A B H1 H2 D L1 L MOUNTING POWER dischargeHOLE DIA (KW/HP)

RMH-0602 80 100 63 162 114 155 380 7 0.25/0.33 #

RMH-0603 90 112 71 170 144 180 465 7 0.37/0.5 #

RMH-0604 90 112 71 170 144 205 465 7 0.54/0.75

RMH-0606 100 125 80 179 165 255 560 10 0.75/1.0

RMH-0608 100 125 80 179 165 305 610 10 1.1/1.5

DIMENSIONAL DETAILS

REF

ERG

RA

PH

16

HE

AD

IN

M.T

R.S

1” BSP

1” BSP

COOLANT PUMPS

R

MULTISTAGE COOLANT PUMP RKM - 100 SERIES

CONSTRUCTION

Body C.I./A.L.Stem C.I.Impeller A.L.Impeller Cover C.I.Shaft EN8Bush Bearing GM

OPTIONS

Stem GunmetalImpeller C.I./Gunmetal/BrassImpeller Cover Gunmetal/S.S.Shaft S.S. 410Bush Bearing SiC/SiC

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

Kinematical Viscocity - 90 mm2/sPumping Temperature - 0-800C

SPECIAL VERSIONS

Avilable• With Flame Proof Motors to pump hazardous liquids• With dual speed motor• For chiller units

USED ON

All CNC machines lathes and machining centres.Most suited for through tool cooling, deep holedrilling etc. Also suitable for Industrial washing.

• STANDARD SPARES : IMPELLER, BUSH AND SPACERS.

Type Immersion H1 H2 A+0 B D d d1 E F L1 L3 Power in WTDepth Max Max -1 Max Max -0.2 BSP Max KW in KG

RKM-120 215 160 320265 225 360 140 82 140 160 1” 30 180 105 110 0.54 20315 275 360

RKM-130 230 130290 160 340 140 82 157 160 1” 30 180 125 110 1.1 31330 210

RKM-140 265 150335 225 355 140 82 170 160 1” 30 180 135 110 1.5 40385 275

RKM-150 300 150370 220 355 140 82 170 160 1” 30 180 135 110 1.7 42420 270

RKM-160 340 150410 330 355 140 82 170 160 1” 30 180 135 110 2.0 46460 380

17

HE

AD

IN

ME

TR

ES

COOLANT PUMPS

R

MULTISTAGE COOLANT PUMPS RKM200 & RKM300

CONSTRUCTION

Body C.I.Stem C.I.Impeller BrassImpeller Cover C.I.Guide vane Noryl-30% GFShaft EN8Mechanical Seal Carbon/CeramicBush/Sleeve Carbon/Carbon

OPTIONS

Stem GunmetalImpeller C.I.Impeller Cover Gunmetal/S.S.Shaft S.S.Mechanical Seal SiC/SiC

(for Grinding)Bush/Sleeve SiC/SiC

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

Kinematical Viscocity - 90mm2/sPumping Temperature - 0-500C

SPECIAL VERSIONS

Avilable• With Flame Proof Motors to pump hazardous liquids• With dual speed motor• Booster arrangment (see page 10)• Side suction arrangement (see page 10)

USED ON

All CNC machines lathes and machining centres.Most suited for through tool cooling, deep holedrilling etc. Also suitable for Industrial washing,grinding Machine.

• STANDARD SPARES : IMPELLER, BUSH & SLEEVE, MECHANICAL SEAL AND SPACERS

TYPE NO OF IMMERSION H1 H2 A+0 B D d d1 S F L1 L2 KwSTAGES DEPTH H MAX MAX -1 MAX MAX ±0.2 BSP MAX

RKM-206 6 290 180 410 140 82 208 180 1" 9 220 165 110 2.25RKM-210 10 430 320 410 140 100 225 180 1" 9 220 215 110 3.0RKM-214 14 580 480 410 140 100 225 180 1" 9 220 215 110 4.0RKM-218 18 710 580 410 140 100 225 180 1" 9 220 215 110 5.5RKM-222 22 830 720 480 140 110 280 180 1" 9 220 220 110 7.5RKM-226 26 970 840 480 140 110 280 180 1" 9 220 220 110 7.5RKM-304 4 250 120 370 140 82 208 180 1" 9 220 165 110 2.25RKM-306 6 340 190 410 140 100 225 180 1" 9 220 215 110 3.0RKM-308 8 420 280 480 140 110 280 180 1" 9 220 220 110 3.7RKM-310 10 500 350 480 140 110 280 180 1" 9 220 220 110 5.5

18

HE

AD

IN

ME

TR

ES

DISCHARGE IN LPM

COOLANT PUMPS

R

MULTISTAGE COOLANT PUMP RKM 250 SERIES

CONSTRUCTION

Body C.I./AL.Stem C.I.Impeller AL.Impeller Cover C.I.Shaft EN8Bush Bearing Carbon/GM

OPTIONS

Stem GunmetalImpeller C.I./GunmetalImpeller Cover GunmetalShaft S.S.410Bush Bearing Carbide

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

Kinematical Viscocity - 90 mm2/sPumping Temperature - 0-800C

SPECIAL VERSIONS

Avilable• With flame proof motor for hazardous liquids• With dual speed motor

USED ON

All CNC machines, lathes, and machiningcentres. Most suited for through tool cooling,deep hole drilling, chilling units and industrialwashing machine, grinding machine.

• STANDARD SPARES : IMPELLER, BUSH & SLEEVE, MECHANICAL SEAL AND SPACERS

TYPE IMMERSION H1 H2 A+0 B D d d1 E+0 F L1 L3 Kw WtDEPTH H MAX MAX -1 MAX MAX -0.2 BSP -1 MAX in Kg

RKM-252 150 95 260 140 75 157 160 1¼" 20 180 126 110 1.1 26205 135 340 140 79 157 160 1¼" 30 180 126 110 1.1 30280 205330 255

RKM-253 265 190335 260 340 140 79 157 160 1¼" 30 180 126 110 1.5 34385 310

RKM-254 320 240390 310 355 140 79 178 160 1¼" 30 180 126 110 1.7 46440 380

RKM-255 375 295445 365 375 140 82 208 160 1¼" 30 180 165 110 2.25 54495 435

HE

AD

IN

ME

TR

ES

DISCHARGE IN LPM

19

COOLANT PUMPS

R

HIGH PRESSURE HIGH DISCHARGE COOLANT PUMPS RMS 400 & 800

CONSTRUCTION

Body C.I.Stem C.I.Impeller C.I.Impeller Cover C.I.Shaft EN8Bush/Sleeve EN31/EN24

OPTIONS

Stem GunmetalImpeller C.I./GunmetalImpeller Cover GunmetalShaft S.S.Bush/Sleeve Carbide

APPLICATION

Types of Fluids - Water- Cooling Emulsion- Cooling/Cutting Oils

Kinematical Viscocity - 90 mm2/sPumping Temperature - 0-800C

SPECIAL VERSIONS

Avilable• With flame proof motor for hazardous liquids.• to handle larger chips for transfer to filteration unit.

USED ON

All CNC machines, lathes, machining centres,Most suited for grinding m/c.s, filteration unitschip conveyors, washing machines, etc.

• STANDARD SPARES: IMPELLER, BUSH & SLEEVE (IF USED)

HE

AD

IN

ME

TR

ES

DISCHARGE IN LPM

20

TYPE IMMERSION H1 H2 A+0 B D d d1 E+0 F L1 L3 Kw WtDEPTH H MAX MAX -1 MAX MAX -0.2 BSP -1 MAX in Kg

RMS-402 375 295 310 200 82 156 225 2" 42 250 126 126 3.0 30RMS-403 450 370 360 200 82 225 225 2” 42 250 165 126 4.0 45RMS-404 525 445 375 200 82 230 225 2" 42 250 180 126 5.5 50RMS-406 675 595 430 200 82 200 225 2" 42 250 180 126 7.5 65RMS-602 375 295 465 200 82 230 225 2" 42 250 165 126 4.0 53RMS-604 525 445 465 200 82 230 225 2" 42 250 180 126 7.5 62RMS-802 375 295 465 200 82 230 225 2" 42 250 180 126 7.5 56RMS-803 450 370 465 200 82 230 225 2” 42 250 180 126 9.0 70

COOLANT PUMPS

R

• STANDARD SPARES: BELT, DRIVEN PULLEY, WIPER, DISC

OIL SKIMMERS - ROS SERIES

CONSTRUCTION

Motor Body Powder coatedSupport Assembly Powder coatedBelt PUWiper TeflonDrive Pulley SS410Driven Pulley Nylon

OPTIONS

Motor Body SS316/304Support Assembly SS316/304Belt PVC/SS316Driven Pulley SS316/304Oil collection/seperationtray with mounting railings

APPLICATION

Types of Fluids - Oils- Coolant Emulsion- Mild Chemicals

Liquid Temperature - 0-500C

STANDARD ACCESSORIES

• TIMER - FOR ROS1 & ROS2

USED ON

All CNC machines, conventional machines,washing machine, electro plating grindingmachines, etc. where floating oil is to beextracted for better life of coolant and finish ofcomponents.

ROS2 - DISC TYPE 230V, 1 PHASE

MODEL : ROS2 - 5 - 215

ROS1 - BELT TYPE230V1, 1 PHASE.

21

Dimensions of ROS1 models:

Model Belt Immersionwidth Depth

ROS1-40-225 40 225ROS1-40-300 40 300ROS1-40-500 40 500

COOLANT PUMPS

R

OIL SKIMMERS - ROS SERIES

22

CONSTRUCTION

Motor Body ALImpeller Al./BronzeShaft SS410

APPLICATION

Types of Fluids - Water- Coolant Emulsion

Liquid Temperature - 0-800C

SPECIAL VERSIONS

• Available with Flame Proof Motors.• Any immersion depth Upto 600 mm

USED ON

Chilling units, Mixing barrels,coolant tanks, etc.

TYPE H1 H2 A+0 d F S D L1 POWER WeightMAX -1 PCD MAX MAX (KW/HP) in Kg.App.

RSB63L 225 210 95 115 140 10 120 115 0.18/0.25 10275

RSB71L 225 250 110 130 160 10 140 125 0.37/0.50 15275

DIMENSIONAL DETAILS

Supply Voltage 415V, 50HZ, 3PH and RPM 1440. Optional RPM 960available for longer immersion stirrers.

• STANDARD SPARES : IMPELLER

Dimensions of ROS3415V, 3PH models:

Model Belt Immersionwidth Depth

ROS3-40-225 40 225ROS3-40-300 40 300ROS3-40-500 40 500ROS3-80-500 80 500

STIRRERS - RSB SERIES

COOLANT PUMPS

R

OTHER SPECIALITY PRODUCTS

For various application incentralized lubrication,hydraulic power pack,units, gear boxes,advertisements, etc.

1. Special voltages-110V, 220V, 560V, etc.2. Speeds - single or dual speeds3. High frequencies - 400Hz, 50/60Hz4. Mountings5. Extended shaft motors6. Special class of insulation & for humid

conditions - like class H.7. Hollow shaft motors8. Torque motors

Standard motors are also manufactured. Ask for detailed catalog of the same.

Auto-Electric parts : Parts manufactured for automobile industry.Special purpose Induction Motors: forSmall Induction motors:

For use in automats, defence equipments, cooling units & many more.SPECIFICATIONS / DIMENSIONS ARE SUBJECT TO CHANGE DUE TOCONTINUOUS IMPROVEMENT IN THE PRODUCTS. 23

CMYK COOLANT PUMPSR