The new Smoke Ventilation, Natural Ventilation & Window Automation brochure is intended to give specifiers of natural ventilation and smoke control systems a broad overview of the requirements and products available for covering such systems.
Citation preview
secontrols.com
UniclassL7535
CI/SfB(57) X
EPICL13
Smoke Ventilation, Natural Ventilation and Window Automation
3
We formed SE Controls almost 30 years ago, at a time when the use of window automationwas in its infancy. Through continued reinvestment in research and development we havegrown in to one of the pre-eminent companies delivering natural ventilation, smoke controland window automation solutions throughout the world. We use cutting edge technologiesand simulation packages to optimise designs for the benefit of our clients.
Our solutions…
Now on a global stage, we offer our expertise to designers who want to createenvironmentally friendly, naturally ventilated and safe buildings. We want to share our 30years experience of literally thousands of projects with our partners to optimise every solution.
We want…
Through optimal design, buildings can consume less energy and be healthier, safer places towork and live. We are actively involved in every stage of the life cycle of the building – fromplanning and early design to delivery and installation through to post occupancy optimisationand maintenance. We have a reputation and a retained client base that underlines theexcellence of our solutions.
secontrols.com
Lichfield, UK
Hong Kong, China Shenzhen, China
Beijing, China
Shanghai, China
Bahrain
Durban, South AfricaCape Town, South Africa
Johannesburg, South AfricaSao Paulo, Brazil
4
Design & Cost Planning
During early design stages SE Controls can assist the client and design team in specifyingthe most cost efficient and practical solution for natural ventilation, smoke ventilationand window automation.
Approval and Tendering Process
SE Controls offers coordination with the client, the approving body and biddingcontractors throughout the tendering process.
• Coordination with approving body
• Production of specifications for tendering
• Planning and mid-tender meetings.
Coordination
At early stages of the project vital information is required by the contractor. AOVopenings may be built into the shell and the core of the building including, walls, roofsand façades.
Commissioning Handover, Training and Optimisation
During the final completion stages of the project build phase, SE Controls willcommission the ventilation system. This will typically involve detailed cause and effecttesting of all the system components against the design specification. Our trainedcommissioning engineers will then hand over the system to the client together withdetailed operating instructions and training. After occupation the system can beoptimised to suit client requirements.
Cable Installation
Full wiring schematics are produced for cableinstallation with all devices located anddetailed. This work can be carried out by SEControls or the contractor who is already onsite.
Product Installation
At suitable stages the associated ventilationproducts are installed and connected. SEControls ventilation products are certified andcompliant to International standards and areCE marked.
“We want to help our clients optimise their buildingthroughout its life”
5
secontrols.com
Maintenance
SE Controls maintenance departmentoffer problem solving, advice andalternative solutions to existing systemsthat require modification orrefurbishment, to ensure reliability andpeace of mind across multiple sites.
SE Controls’ investment in cutting-edgetechnology allows our products to beoptimised to maximise performance of oursystems. These improvements can deliverincreased efficiency, safety andfunctionality of our customers’ ventilationsystems. Our modifications comply withthe Buildings Regulations and Europeanand British Standards.
6
Smoke ventilation
Fire costs money. The cost as aconsequence of fire, including propertydamage, human casualties and lostbusiness, was estimated at £2.5 billion inthe UK. If a fire does occur thenoccupants must be protected.
SE Controls offers a comprehensive rangeof natural and powered Smoke Heat andExhaust Ventilation systems (SHEV)suitable for any size and type of building.Systems are designed to facilitate the safeescape of occupants in the event of a fireand to enable the fire to be fought in itsearly stages.
7
secontrols.com
Smoke ventilation allows the creationof a smoke free layer above the floorby removing smoke. This improves theconditions for safe escape and permitsthe fire to be fought in its early stages.
What happens if there is no means ofsmoke ventilation?
1. In an unventilated room, smoke will risedirectly to the ceiling.
2. The smoke will begin to fill the spaceavailable moving laterally instead ofvertically.
3. Convection of the smoke will cause it to bedrawn back down to low level reducingvisibility and the chances of a safe escape.
4. Temperatures will continue to rise causingthe potential flash over and collapse of thebuilding.
What happens if there is a smokeventilation system?
1. ln the event of a fire, actuators open highlevel smoke vents and low level fresh airinlet vents.
2. This allows cool air into the building,forcing the hot air and smoke out via theroof, providing a smoke free layer for safeescape.
3. The smoke free layer allows safe access forthe fire to be fought and extinguished.
1 2
3
1 2
3
4
8
Natural Ventilation
Natural ventilation improves indoor environments, reduces CO2 emissions and is cost efficient.Adaptive natural ventilation systems are less costly than traditional HVAC systems, beingcheaper to install, run and maintain. With buildings currently consuming almost half of allcommercial energy usage, producing 50% of global carbon emissions, adaptive naturalventilation is leading the way for a sustainable future.
SE Controls are passionate about delivering energy efficient buildings with productive, healthyindoor environments; occupant productivity is significantly improved when thermal comfort andindoor air quality are optimised. SE Controls’ turnkey solution incorporates design, supply,installation and commissioning through to maintenance.
Natural Ventilation Principles
SE Controls’ Natural Ventilation strategiesare based on six stand-alone principles,which function differently depending onthe building shape, internal heat loadsand location of openings. Common waysof capitalising on ‘free’ air movement isthrough the stack effect, cross ventilationand passive night time cooling usingopening windows to facilitate the naturalventilation.
9
secontrols.com
Stack Ventilation Night or Passive Cooling Ventilation Cross Ventilation
Trickle Ventilation Single Sided Ventilation Mixed Mode Ventilation
10
Window Automation
The use of actuators to automate windows can beused in both natural and smoke ventilation systems byreacting to sensors (rather than human response tostimuli) to control the level of comfort within an indoorenvironment, or to clear smoke to aid in the means ofescape or fire fighting operations.
Automating a facade can also provide convenience forthe building occupants. Large heavy vents can be easilyoperated and held at various angles where appropriateto ensure the level of ventilation is sufficient.
Natural Ventilation by Automatic WindowControl
Automatic opening windows can provide an efficientway of cooling a building and removing airbornecontaminates inexpensively and effectively, to improvethe indoor environment for its occupants.
For natural ventilation systems, the window openingscan be controlled by smart algorithms to provide agreater efficiency of comfort. Operating in this manorrather than opening the windows in an arbitrarypattern provides more flexibility to changing externalconditions for increased ventilation rates.
Smoke Ventilation by Automatic Window Control
The automation of windows or vents for smokeventilation is widespread as it is a cost effective way ofdelivering a smoke ventilation system, with low capitalcost but also the added advantages that it allowsnatural daylight in as well as doubling as a naturalventilation system.
By introducing automatic vents at high level that openupon detection of smoke, the smoke is allowed toescape to the atmosphere providing a clear escaperoute and increased visibility for the fire service to enterthe affected area.
11
secontrols.com
Manual Window Control
Manual opening vents are used in applications where anumber of high level out of reach windows or roof lightsystems require remote operation safely and securely.
Manual opening systems can be used for most windowsystems and can be applied to all forms of windows,bottom hung, top hung, side hung and central pivotalorientations.
SE Controls has the ability to design and install tailoredsolutions to meet the remote manual controlrequirements for natural ventilation in, offices, schools,colleges, hospitals, public buildings and shoppingcenters.
The operation of remotely opening either a single ornumber of high level windows can be achieved by ourrange of rotary handles available in a range of colours tomeet the window profile and actuator to provide aninconspicuous solution.
12
Residential Solutions
OS2 Manual Control Point(MCP)
0S2 Control System 0S2 Loop Control System Repeater Panel Smoke Detector Linear Actuator (Auto) Chain Actuators (Auto)
SHEVTEC® Powered Extract Fans
13
secontrols.com
End of wall corridor AOV
If the corridor extends to theexternal wall an AOV can beinstalled to remove smoke fromthe common corridor/lobby.
Escape/Fire Fighting stair
The prime objective of a smokecontrol strategy is to keep theescape stair free from smoke, byusing the natural buoyancy of thehot gases to exhaust throughAOVs.
Mechanical Smoke Shaft
It is not always viable to install aprescribed natural smoke shaft,in which case a mechanicalsmoke shaft would be installed.
Natural Smoke Shaft
A natural smoke shaft utilisesautomatic opening smoke doorsor dampers to draw smoke intothe smoke shaft and out theaffected area through a roof ventat the top of the shaft.
SHEVTEC® Smoke ShaftDoor and Actuator
Bottom Hung AOV SHEVTEC® Glazed LouvreAOV
SHEVTEC® 140º OpeningRoof Vent
SHEVTEC® Double OpeningRoof Vent
Side Hung Opening AOV SHEVTEC® Damper
14
Residential Projects
ABOVE: Battersea ReachLONDON
TOP RIGHT: St. George WharfLONDON
RIGHT: The Chips BuildingMANCHESTER
FAR RIGHT: One Hyde ParkLONDON
16
Education Solutions
Atria (Natural Ventilation)
Atria are now a common feature in schoolsand universities, providing natural ventilationand light and thus saving energy.
Atria (Smoke Ventilation)
Automatic opening vents (AOVs) are used toexhaust hot buoyant smoke to maintain thesmoke reservoir within the atria to assist withthe means of escape strategy.
External Façade
External façades are used in a naturalventilation strategy to provide openings foreither single sided or cross ventilation.
Internal Glazed Screen/Façade
Within an education building, the internalglazed screen can be designed to provideventilation, additional light and visibility intoadjacent spaces.
0S2 Control System NV Controller 0S2 Module Power Supply Repeater Panel Wind Speed and DirectionSensor
SHEVTEC® & NVS GlazedLouvre AOV
Rain Sensor
Remote Rotary Handle(Manual)
SHEVTEC® AluminiumUpstand Damper
Bottom Hung AOV Sloping Roof Vent AOV Parallel Opening AOV
17
secontrols.com
C02 & Temperature Sensor External Temperature Sensor Smoke Detector Manual Override Switch/KeySwitch
Linear Actuator (Auto) Chain Actuator (Manual)Chain Actuators (Auto)
18
Education Projects
ABOVE: Hackney City AcademyLONDON
RIGHT: Fibbersley Primary SchoolWOLVERHAMPTON
TOP RIGHT: Langley AcademyLONDON
FAR RIGHT: Capital City AcademyLONDON
Commercial Solutions
20
Atria (Natural Ventilation)
Atria are often used as a pump for drawingwarm stale air from adjacent spaces andexhausting it to outside.
Atria (Smoke Ventilation)
Automatic opening vents (AOVs) are used toexhaust hot buoyant smoke to maintain thesmoke reservoir within the atria to assist withthe means of escape strategy.
External Façade
The external façade is typically used in naturalventilation strategies to provide either singlesided or cross ventilation.
Internal Glazed Screen/Façade
Within an education building, the internalglazed screen can be designed to provideventilation, additional light and visibility intoadjacent spaces.
Smoke Shaft
A smoke shaft can be provided where the firefighting core is not located on the externalwall to provide smoke ventilation of the firefighting lobby.
Head of Fire Fighting Stair
An automatic opening vent (or manually via aManual Control Point activated from FireService Access level) with 1m2 free area isrequired to the head of the stair to clear anysmoke ingress.
Smoke Shaft External Façade Atria
0S2 Control System
Remote Rotary Handle(Manual)
NV Controller 0S2 Module Power Supply Repeater Panel Wind Speed and DirectionSensor
Rain Sensor
SHEVTEC® Smoke ShaftDoor and Actuator
SHEVTEC® AluminiumUpstand Damper
Bottom Hung AOV Sloping Roof Vent AOV Parallel Opening AOV SHEVTEC® 140º OpeningRoof Vent
21
secontrols.com
SHEVTEC® Double OpeningRoof Vent
C02 & Temperature Sensor External Temperature Sensor Smoke Detector Manual Override Switch/KeySwitch
Linear Actuator (Auto) Chain Actuator (Manual)Chain Actuators (Auto)
SHEVTEC® & NVS GlazedLouvre AOV
SHEVTEC® Damper SHEVTEC® Powered Extract Fans
23
secontrols.com
FAR LEFT: DOFASOUTH AFRICA
BOTTOM LEFT: Bangkok International AirportTHAILAND
MIDDLE LEFT: The MailboxBIRMINGHAM
LEFT: Liverpool South ParkwayLIVERPOOL
BELOW: Lime Street (Willis Building)LONDON
Healthcare Solutions
24
Atria (Natural Ventilation)
Atria are often used as a pump for drawingwarm stale air from adjacent spaces andexhausting it to outside.
Atria (Smoke Ventilation)
Automatic opening vents (AOVs) are used toexhaust hot buoyant smoke to maintain thesmoke reservoir within the atria to assist withthe means of escape strategy.
External Façade
The external façade is typically used in naturalventilation strategies to provide either singlesided or cross ventilation.
Internal Glazed Screen/Façade
Within an education building, the internalglazed screen can be designed to provideventilation, additional light and visibility intoadjacent spaces.
Smoke Shaft
A smoke shaft can be provided where the firefighting core is not located on the externalwall to provide smoke ventilation of the firefighting lobby.
Head of Fire Fighting Stair
An automatic opening vent (or manually via aManual Control Point activated from FireService Access level) with 1m2 free area isrequired to the head of the stair to clear anysmoke ingress.
Smoke Shaft External Façade Atria
0S2 Control System
Remote Rotary Handle(Manual)
NV Controller 0S2 Module Power Supply Repeater Panel Wind Speed and DirectionSensor
Rain Sensor
SHEVTEC® Smoke ShaftDoor and Actuator
SHEVTEC® AluminiumUpstand Damper
Bottom Hung AOV Sloping Roof Vent AOV Parallel Opening AOV SHEVTEC® 140º OpeningRoof Vent
25
secontrols.com
SHEVTEC® Double OpeningRoof Vent
C02 & Temperature Sensor External Temperature Sensor Smoke Detector Manual Override Switch/KeySwitch
Linear Actuator (Auto) Chain Actuator (Manual)Chain Actuators (Auto)
SHEVTEC® & NVS GlazedLouvre AOV
SHEVTEC® Damper SHEVTEC® Powered Extract Fans
27
secontrols.com
LEFT & ABOVE: Evelina Children’s HospitalLONDON
BELOW: Walsall Manor HospitalWALSALL
secontrols.comSE Controls
Lancaster House
Wellington Crescent
Fradley Park
Lichfield
Staffordshire WS13 8RZ
Tel: +44 (0)1543 443060
Fax: +44 (0)1543 443070
Email: [email protected]
Visit us at: www.secontrols.com
SE Controls is a Registered Trademark Creating a Healthier and Safer Environment