SmartWire-DT Connectivity
DS7 Soft Start Controllers DC1 Drives XTPE MMPs SL4/SL7 Stacklights
2 © 2013 Eaton. All Rights Reserved.
3 © 2013 Eaton. All Rights Reserved.
SmartWire-DT DS7 Soft Start Controllers
• Two phase SCR control with patented algorithm
• Suitable for variable torque loads • Integrated SmartWire-DT • Network programmable • Start ramp, start torque, stop ramp • 24Vac/dc; 110/230Vac controls • Four frame sizes, from 2 to 150HP
@ 480V (4 to 180 FLA) • 300% SCRs; 30 seconds ramp
4 © 2013 Eaton. All Rights Reserved.
DS7 Setup on SWD-Assist
5 © 2013 Eaton. All Rights Reserved.
SmartWire-DT DC-1 VF Drives
• Constant torque applications • High overload capability
• 150% for 60s; 175% for 2s
• Modbus RTU & CANopen • Onboard I/O (4I/2O) • 1Ø/1Ø; 1Ø/3Ø; 3Ø/3Ø • 1-15HP @ 480V • Plug-in SWD module • Cat # DX-NET-SWD3
6 © 2013 Eaton. All Rights Reserved.
DC1 – IP20 FS 1 - 3
Communication Interface RJ45 CANopen & Modbus RTU included as standard
Info Card
LED Display
DIN rail mounting (FS1-2)
Detachable Control Terminals
Line Terminals
Load Terminals
7 © 2013 Eaton. All Rights Reserved.
DC1 - Accessories 1) DC1 - Compact Drive 2) Mains- / Motor-Chokes 3) Braking resistors 4) Expanded I/O 5) SmartWire-DT module 6) Communication-/Copy-Stick 7) Remote Keypads
8 © 2013 Eaton. All Rights Reserved.
DC1 Setup on SWD-Assist
9 © 2013 Eaton. All Rights Reserved.
SmartWire-DT Electronic MMP Modules
• For electronic XTPE MMPs only • Same module for 12/32A & 65A
frame • Cat # PKE-SWD-SP
10 © 2013 Eaton. All Rights Reserved.
PKE Setup on SWD-Assist
11 © 2013 Eaton. All Rights Reserved.
Design • Modular, compact and flexible • 2 diameter offerings • High performance LED option for outdoor
applications • UL Type 4/4X/13 (IP66) acoustics, bases, light units • Operating voltages – 24Vac/Vdc, 120 & 240Vac
Options • 4 lighting modes – continuous, flashing, strobe,
multi-strobe • 6 bright LED colors, 9 mounting styles • Adjustable and selectable alarms
SL7 70mm SL4
40mm
SL4/SL7 Stacklights
12 © 2013 Eaton. All Rights Reserved.
Up to 5 modules
with base unit or 10 for double
base mount
9 mounting options
6 LED options or Incandescent lights
Twist and Lock
SL7 Stacklight Options
13 © 2013 Eaton. All Rights Reserved.
Transportation cover protects cables and terminals
Quick-disconnect for fast mounting and dismantling • Ship stacklight separately from machine • Unpack and connect stacklight in
seconds
Rotate to lock and
unlock base
Stacklight Fast-Mount Base
14 © 2013 Eaton. All Rights Reserved.
SmartWire-DT SL4 & SL7 Stacklights
• Available in both 40mm & 70mm diameter
• Up to 5 modules • Accepts external 24Vdc source if
needed
15 © 2013 Eaton. All Rights Reserved.
SmartWire-DT SL4 & SL7 Stacklights
• Available in both 40mm & 70mm diameter
• Up to 5 modules • Accepts external 24Vdc source if
needed
16 © 2013 Eaton. All Rights Reserved.
SL4/SL7 Setup on SWD-Assist
17 © 2013 Eaton. All Rights Reserved.
FEATURES • Connects to any PLC • An easy way to connect vs wire • Low cost connectivity to standard devices • On board 24Vdc power for contactors • Elimination of PLC I/O modules and associated hard wired connections
• Up to 99 nodes per gateway • 2,000 foot long network
SmartWire-DT Quick Reference Guide
OFFERING • Gateways for any PLC
• EtherNet/IP, Modbus TCP, PROFINET, POWERLINK, PROFIBUS-DP, CANopen
• Controllers • XV HMI-PLC, easy802/806, XC-152 PLC)
• M22 pilot device modules • SL4/SL7 stacklights • XT contactor modules (B & C frames) • XTPE MMP modules (up to 65A) • DC1 compact drives (up to 15HP @ 480V) • DS7 soft start controllers (up to 150HP @ 480V) • Digital & analog I/O modules • Crimp tools, flat & round cables and accessories
18 © 2013 Eaton. All Rights Reserved.
19 © 2013 Eaton. All Rights Reserved.
SmartWire-DT Polling Cycle Time
10
18
26
34
42
50
58
66
74
82
12
20
28
36
44
52
60
68
76
84
0
10
20
30
40
50
60
70
80
90
100 200 300 400 500 600 700 800 900 1000
POLL
ING
CYC
LE T
IME
(mS)
TOTAL NUMBER OF DATA BYTES
1 Node
99 Nodes
DEVICE NODEM22 Contact 1 ByteM22 LED or LED & Contact 2 BytesXT Contactor Modules 2 BytesXTPE Contactor/MMP Module 3-6 BytesDigital I/O Module 8I 2 BytesDigital I/O Modules 4I/4O or 4I/2O 3 BytesDS7 Soft Start Controllers 4-9 BytesDS7 & XTPE 3-14 BytesDC1 Drives 4-9 BytesXTPE MMPs 3-6 BytesSL4/SL7 Stacklights 2 Bytes
DATA
20 © 2013 Eaton. All Rights Reserved.
Taking SmartWire-DT outside the main control cabinet
The Next Step for Smartwire: On-Machine Reliable machine
Simplified, compact & lower cost machine
Energy efficient machine
Safer machine
• Single cable along and around the machine for standard controls, low density hydraulic requirements
• Flexible density from single point to block-style 4, 8, and 16 I/O versions
• Dramatic reductions in total cabling, assembly and commissioning time
• Automatic device addressing, diagnostics, simplified troubleshooting
• Available today (beta testing), Summer/Fall 2014 (market launch)