SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

© 2013 Eaton. All Rights Reserved.

SmartWire-DT Connectivity

DS7 Soft Start Controllers DC1 Drives XTPE MMPs SL4/SL7 Stacklights

Page 2: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

2 © 2013 Eaton. All Rights Reserved.

Page 3: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

3 © 2013 Eaton. All Rights Reserved.

SmartWire-DT DS7 Soft Start Controllers

• Two phase SCR control with patented algorithm

• Suitable for variable torque loads • Integrated SmartWire-DT • Network programmable • Start ramp, start torque, stop ramp • 24Vac/dc; 110/230Vac controls • Four frame sizes, from 2 to 150HP

@ 480V (4 to 180 FLA) • 300% SCRs; 30 seconds ramp

Page 4: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

4 © 2013 Eaton. All Rights Reserved.

DS7 Setup on SWD-Assist

Page 5: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

5 © 2013 Eaton. All Rights Reserved.

SmartWire-DT DC-1 VF Drives

• Constant torque applications • High overload capability

• 150% for 60s; 175% for 2s

• Modbus RTU & CANopen • Onboard I/O (4I/2O) • 1Ø/1Ø; 1Ø/3Ø; 3Ø/3Ø • 1-15HP @ 480V • Plug-in SWD module • Cat # DX-NET-SWD3

Presenter
Presentation Notes
High overload capability (150% for 60s; 175% for 2s) Integrated Modbus RTU and CANopen Integrated PID controller V/Hz control with voltage boost Onboard I/O (4 inputs [2DI, 2DI/AI], 1 DO/AO, 1 relay output) Single phase input to 3 phase output version
Page 6: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

6 © 2013 Eaton. All Rights Reserved.

DC1 – IP20 FS 1 - 3

Communication Interface RJ45 CANopen & Modbus RTU included as standard

Info Card

LED Display

DIN rail mounting (FS1-2)

Detachable Control Terminals

Line Terminals

Load Terminals

Presenter
Presentation Notes
SWDT module
Page 7: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

7 © 2013 Eaton. All Rights Reserved.

DC1 - Accessories 1) DC1 - Compact Drive 2) Mains- / Motor-Chokes 3) Braking resistors 4) Expanded I/O 5) SmartWire-DT module 6) Communication-/Copy-Stick 7) Remote Keypads

Presenter
Presentation Notes
Frames 2 and 3 for DA1/DC1 integrated brake choppers in DA1 and optional DC1 Slot underneath to integrate break resistor Resistor values are dependent on the load that is stopped Remote keypad and the communication stick will go through the RJ45
Page 8: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

8 © 2013 Eaton. All Rights Reserved.

DC1 Setup on SWD-Assist

Page 9: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

9 © 2013 Eaton. All Rights Reserved.

SmartWire-DT Electronic MMP Modules

• For electronic XTPE MMPs only • Same module for 12/32A & 65A

frame • Cat # PKE-SWD-SP

Page 10: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

10 © 2013 Eaton. All Rights Reserved.

PKE Setup on SWD-Assist

Page 11: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

11 © 2013 Eaton. All Rights Reserved.

Design • Modular, compact and flexible • 2 diameter offerings • High performance LED option for outdoor

applications • UL Type 4/4X/13 (IP66) acoustics, bases, light units • Operating voltages – 24Vac/Vdc, 120 & 240Vac

Options • 4 lighting modes – continuous, flashing, strobe,

multi-strobe • 6 bright LED colors, 9 mounting styles • Adjustable and selectable alarms

SL7 70mm SL4

40mm

SL4/SL7 Stacklights

Page 12: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

12 © 2013 Eaton. All Rights Reserved.

Up to 5 modules

with base unit or 10 for double

base mount

9 mounting options

6 LED options or Incandescent lights

Twist and Lock

SL7 Stacklight Options

Page 13: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

13 © 2013 Eaton. All Rights Reserved.

Transportation cover protects cables and terminals

Quick-disconnect for fast mounting and dismantling • Ship stacklight separately from machine • Unpack and connect stacklight in

seconds

Rotate to lock and

unlock base

Stacklight Fast-Mount Base

Page 14: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

14 © 2013 Eaton. All Rights Reserved.

SmartWire-DT SL4 & SL7 Stacklights

• Available in both 40mm & 70mm diameter

• Up to 5 modules • Accepts external 24Vdc source if

needed

Presenter
Presentation Notes
High overload capability (150% for 60s; 175% for 2s) Integrated Modbus RTU and CANopen Integrated PID controller V/Hz control with voltage boost Onboard I/O (4 inputs [2DI, 2DI/AI], 1 DO/AO, 1 relay output) Single phase input to 3 phase output version
Page 15: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

15 © 2013 Eaton. All Rights Reserved.

SmartWire-DT SL4 & SL7 Stacklights

• Available in both 40mm & 70mm diameter

• Up to 5 modules • Accepts external 24Vdc source if

needed

Presenter
Presentation Notes
High overload capability (150% for 60s; 175% for 2s) Integrated Modbus RTU and CANopen Integrated PID controller V/Hz control with voltage boost Onboard I/O (4 inputs [2DI, 2DI/AI], 1 DO/AO, 1 relay output) Single phase input to 3 phase output version
Page 16: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

16 © 2013 Eaton. All Rights Reserved.

SL4/SL7 Setup on SWD-Assist

Page 17: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

17 © 2013 Eaton. All Rights Reserved.

FEATURES • Connects to any PLC • An easy way to connect vs wire • Low cost connectivity to standard devices • On board 24Vdc power for contactors • Elimination of PLC I/O modules and associated hard wired connections

• Up to 99 nodes per gateway • 2,000 foot long network

SmartWire-DT Quick Reference Guide

OFFERING • Gateways for any PLC

• EtherNet/IP, Modbus TCP, PROFINET, POWERLINK, PROFIBUS-DP, CANopen

• Controllers • XV HMI-PLC, easy802/806, XC-152 PLC)

• M22 pilot device modules • SL4/SL7 stacklights • XT contactor modules (B & C frames) • XTPE MMP modules (up to 65A) • DC1 compact drives (up to 15HP @ 480V) • DS7 soft start controllers (up to 150HP @ 480V) • Digital & analog I/O modules • Crimp tools, flat & round cables and accessories

Page 18: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

18 © 2013 Eaton. All Rights Reserved.

Page 19: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

19 © 2013 Eaton. All Rights Reserved.

SmartWire-DT Polling Cycle Time

10

18

26

34

42

50

58

66

74

82

12

20

28

36

44

52

60

68

76

84

0

10

20

30

40

50

60

70

80

90

100 200 300 400 500 600 700 800 900 1000

POLL

ING

CYC

LE T

IME

(mS)

TOTAL NUMBER OF DATA BYTES

1 Node

99 Nodes

DEVICE NODEM22 Contact 1 ByteM22 LED or LED & Contact 2 BytesXT Contactor Modules 2 BytesXTPE Contactor/MMP Module 3-6 BytesDigital I/O Module 8I 2 BytesDigital I/O Modules 4I/4O or 4I/2O 3 BytesDS7 Soft Start Controllers 4-9 BytesDS7 & XTPE 3-14 BytesDC1 Drives 4-9 BytesXTPE MMPs 3-6 BytesSL4/SL7 Stacklights 2 Bytes

DATA

Presenter
Presentation Notes
This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT as a function of number of devices and total data size. It shows that the polling time is mostly dependent on total data size.   Given that the devices (contactors, I/O modules ) have relatively small data sizes (1 to 4 bytes per device), systems under 50 devices probably will not have over 100 bytes of data, meaning the polling time will be about 10mS. Now the total worst case delay from sensor state change to PLC input bit change is the sum of the SmartWire-DT polling cycle time and the fieldbus (PROFIBUS-DP or CANopen) polling cycle. So if the SmartWire-DT polling cycle is 10mS and the PROFIBUS-DP polling cycle is 5ms, worst case delay is 15mS.   Polling time is not at all dependent on bus length (meters of cable). M22 contact ................................. 1 byte M22 LED or LED & contact............. 2 bytes XT contactor modules.................... 2 bytes XTPE contactor/MMP module.......... 6 bytes 8I digital I/O module..................... 2 bytes 4I/4O or 4I/2O I/O modules........... 3 bytes
Page 20: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT

20 © 2013 Eaton. All Rights Reserved.

Taking SmartWire-DT outside the main control cabinet

The Next Step for Smartwire: On-Machine Reliable machine

Simplified, compact & lower cost machine

Energy efficient machine

Safer machine

• Single cable along and around the machine for standard controls, low density hydraulic requirements

• Flexible density from single point to block-style 4, 8, and 16 I/O versions

• Dramatic reductions in total cabling, assembly and commissioning time

• Automatic device addressing, diagnostics, simplified troubleshooting

• Available today (beta testing), Summer/Fall 2014 (market launch)

Page 21: SmartWire-DT Connectivity · XTPE MMPs 3-6 Bytes SL4/SL7 Stacklights 2 Bytes DATA. This chart is from the SmartWire-DT system manual. It shows the polling cycle time for SmartWire-DT