July 2017SmartShelter Room
Overview
Perfect enclosure for ISX solutions• Provides physical protection and clean environment
Fast and Easy to Install• Fast delivery and installation• Clean future expansion.
Flexible and Configurable• Different models available for each specific requirements.• Adaptability to dimensions and shapes of existing building room
Secure IT Room anywhere• Fire protection • Water proof• High impact and weight resistant structure
Modular, assemble-on-site IT room combining modularity with the freedom to customize size and shape. Offers a secure, fire-rated, water proof IT room that is highly flexible and configurable
3
o Complete package for a Secure IT room
o Modular and configurableo Fast and Easy assemblyo Adaptability to dimensions and
shapes of the present roomo Clean expansiono Laquered metallic surface – no need
for painting after installationo High thermal insulationo Fire resistanto Water and dust protected
Design Benefits
Converts any existing building space into a secure Data Center
http://www.youtube.com/watch?feature=player_embedded&v=EquUnkP4tywhttp://www.youtube.com/watch?feature=player_embedded&v=EquUnkP4tyw
SmartShelter Room
4
Applications• Small Enterprise / Industrial /
FinanceSmartShelter Room is a cost effective solution to convert any room in a building or industrial environment in a secure datacenter
• Healthcare & EducationHealthcare & Education require a solution that is secure and can be adapted to different sizes, in order to use their existing building
• Government, DefenseGovernment and Military applications require a secure solution, where future expansion and customized security features are a plus.
• Colo & ISPSmartShelter Module provides the flexibility to host specific equipment and an easy expandable solution.
SmartShelter Room fitsperfectly when there are some specific needs:
o Convert existing building room in a secure data center
o Convert industrial environment in a secure data center
o Provide enclosure for ISX solutions
o Modular DC with option for future expansion
Main features
•Better SECURITY: •Fire, Water, Heat, Humidity, EMI-RFI, Dust, Smoke, Tornado, Vandalism,…
•EASY, MODULAR, FLEXIBLE, CLEAN and FAST Installation •Better ROI – DIRECT SAVINGS
•Power EFFICIENCY: THERMAL INSULATION plus better cooling performance, up to 40% •The HVAC units do not have to humidify and dehumidify so often due to the tightness of the room leading to a direct reduction on Power. •Insurance Premium reduction (up to 50%) •Faster Tax Depreciation (up to 40%) – from 1 to 7 years
•GREEN SOLUTION because: •Energy Efficiency – minimal thermal transmission losses •Conservation of Materials and Resources (MODULAR and REUSABLE) •Indoor environmental Quality (CLEAN INSTALLATION and CLEAN ENVIRONMENT)
SmartShelter Room
Main Technical Features
Wall, ceiling and doors: EI 120 fire resistance as per EN 13501-2/EN 1363-1
Fire performing A2-s1, d0 as system testing to EN-13501-1 System testing break-in resistance RC3 in accordance with
EN 1627/1630 (optional) Dust IP 5x as system testing to IEC/EN 60529 Water IP x6 as system testing to IEC/EN 60529 Noise attenuation up to 32,5 dB(A) Thermal insulation up to 0,37 W/K*m2
Electromagnetic emissions and noise immunity as per EN 61000-4-3
CE marked according to standard EN-14509 FEA structural analysis validation TIA 942 design compliance
SmartShelter Room
Converts any existing building space into a secure Data Center
DoorsSimple and double doors
‒ Mechanical & Electric locks
‒ Swing door operator
‒ Panic hardware
Anti-vandalism door (optional)
‒ RC3 EI60
‒ RC4 EI60
‒ RC3 EI120
• Different sizes and purposes> Piping> Electrical cabling> Data cabling
Technical features> Fire rated> Watertight> Gastight > Blast load protection > Bonding and grounding > Approved for hazardous locations
Cable GlandsSmartShelter Room – Technical Features
Fire damperDesign to keep fire protection on the air
ducting
Fits on walls and roof
Galvanized steel
Motorized
Unified apearance
SmartShelter Modules – Technical Features
ARSAir renovation systemDesign based on ASHRAE recomendations
> Air filter G4 (MERV 8)> Air filter F7 (MERV 13)
EC Fans for energy efficiencyOptionals
> Air filter F9 (MERV 16)> Timer> Door switch> Hydrogen sensor
ISX Solution• Racks•InRows• UPS• Electrical distribution• Uniflair Room cooling
Security and Monitoring Options•Access Control on Entry Door•Datacenter Expert•Netbotz environmental monitoring (if not included as standard)
Service PackagesStartup, preventative maintenance, and extended warranty packages available
Raised Floor•Uniflair•Model 30KAL (other models available)•Floor tile 600x600mm•Cooling tiles
SmartShelter Room – Options
Maintenance Service Plans
Packages Initial Period Advantage Plus Advantage Prime Advantage Ultra
Preventive maintenance visits(1)
Next Business day on-site response(2)
Unique point of contact and Remote Monitoring Service
Technical support
Parts(3) All included Discounted rate Discounted rates All included
Labor and travel All included Standard rates All included All included
(1) Preventive visits calendar and equipment checks as per standard SE maintenance program(2) Upgrades to 8h, 4h on-site response time in a 24x7 basis 365 days per year(3) Only included standard equipment consumables. Not included replacement of batteries for UPS.
Available kits of recommended spare parts to be acquired by the client to have available on-site.
Base Designs
Base Design
Base Design A• Small DC Rooms• Beam span up to 6 m• RD56 and RD60
Base Design B• Medium DC Rooms• Beam span up to 12m.• RD13 and RD80
Base Design C• Big DC Rooms• Beam span up to 24m• RD18
Using the Reference Designs available from Schneider we have completed the offer adding SmartShelter Room on top of them.
Base Design A – RD56
Base Design A – RD56
Base Design A – RD60
Base Design B – RD80
Base Design B – RD80
Base Design B – RD13
Base Design C – RD18
Base Design C – RD18
Case Studies
Project concept• Technical Plaform:
‒ Access to Prefab Power Module
‒ Access to MV Substation
‒ Access to Chillers
‒ Acess to Genset and fuel tanks
• IT SPACE :‒ Total IT load 200 kW
‒ IT Floor Space 260 m²
‒ Number of Racks 108
‒ Average Density 1850 W per rack
‒ Maximum density4500 W per rack
• TECHNICAL SUPPORT SPACES:‒ Meet Me Room (1&2)
‒ AHU
‒ Fire Extinction
• Traditional support functions:– Customer access:
– Security
– Meeting room
– Offices
– Sanitary
– Equipment access– Staging
– Stock
Confidential Property of Schneider Electric
https://youtu.be/Gu0UY0-al38
Green Mountain Rjukan DC, Norway
• IT space area: 500 sqm IT• Fast track project 5 months • from scratch incl. building• Scalable & Modular Concept
• from 1kW to 2kW/m²• Tier III Certification - pending• Power Usage Effectiveness < 1,35• Scope: D&B
• Complete Electrical Distribution Package:• 2 MV Substations, 2x500kVA Power Modules, ED in Canalis.
• Complete HVAC Package:• 2 Free-cooling Turbocor Chillers (560kW)• Pipework and Inrow coolers
• CCTV, ACS, Fire Protection, Security, BMS, DCIM, • Wall system, Raised floor• 2 Gensets.
SmartShelter Room
Hosting Company Iceland
http://www.youtube.com/watch?v=EquUnkP4tywhttp://www.youtube.com/watch?v=EquUnkP4tyw
How we build Modular Rooms
SmartShelter Room
• 6 Modular DCMRs* with a total power capacity of 7,3 MW of IT Power in 3000 m2
• Each Modular Room will host a1,2 MW of IT Power
• Tier 3 design
• Energy Efficient Cooling with a projected 1,10 PUE.
• Indirect Free Cooling (NFC*) as Source of Cooling aiming to work 98% of time a year with Free Cooling.
Vimpelcom. Project DetailsSmartShelter Room
Vimpelcom. DCMR* Build As You GrowSmartShelter Room
AMX Claro San Juan (ARG)
Solution:• SmartShelter Room for Outdoors• Flexible design
• ISX built inside• Open vendor for DC equipment
• Build easily Edge / Remote Data Centers to provide better services in all the country
• Expandable solution • Ready to be duplicated• No need to spend all CAPEX upfront
• Standardization• We can replicate the same design around
the country
GERMANY DC
Project Execution
Page 31Confidential Property of Schneider Electric |
Project Execution
Responsible
PARTNER
FRONT OFFICE
PREFAB LOB
Execution Scenarios
• Site Manager: Partner / SE Country / Prefab LOB• Project Manager: Prefab LOB
• Site Manager: SE Country / Prefab LOB• Project Manager: Prefab LOB
• Site Manager: SE Country / Prefab LOB• Project Manager: Prefab LOB
Confidential Property of Schneider Electric
• Prefab LOB will decide, together with the country, the support required from LOB.
• Materials and Prefab LOB support
• Factory Training.
• Technical drawings
• Logistics & Material delivery
• Installation Manual.
• Project supervision.
Project Execution
GENEVE CO-LOCATION DC (1.000 SQM)SmartShelter Room
GENEVE CO-LOCATION DCSmartShelter Room
GENEVE CO-LOCATION DCSmartShelter Room
GENEVE CO-LOCATION DCSmartShelter Room
GENEVE CO-LOCATION DC
European Oil&Gas CompanySmartShelter Room
Confidential Property of Schneider Electric
• SECURITY. • Fire and water protection
• Provide a secure Data Center in an environment not suitable for a Data Center
• ISX.• It’s the perfect companion for ISX, that allows
Schneider to provide a COMPLETE SOLUTION.
• EASY, FAST and CLEAN INSTALLATION
SummaryKey points