SmartSensor HD NEMA Gasket Aging
Test Report
WX-501-0023
Wavetronix products mentioned:SmartSensor HD
As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA gasket aging test on the SmartSensor HD between Febru-ary 24–March 7, 2006. The following report documents the results of the test and is unedited by Wavetronix.
Environ Laboratories LLC9725 Girard Avenue SouthMinneapolis, Minnesota 55431-2621
________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 1 of 12 ENGINEERING REPORT NO. 32767-5
800-826-3710 • FAX 952-888-6345 • 952-888-7795 www.environlab.com
ENGINEERING REPORT NO. 32767-5
GASKET AGING TEST
for
WAVETRONIX LLC 380 SOUTH TECHNOLOGY CT.
LINDON, UT 84042
PREPARED BY:
Michael J. Caron Test Engineer
Tom P. Braun Test Engineer
APPROVED BY:
Bradley C. Czech Vice President
This document shall not be reproduced except in full, without the written authorization of Environ Laboratories LLC.
________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 2 of 12 ENGINEERING REPORT NO. 32767-5
REVISION HISTORY Revision Total Number
of Pages Date Description
-- 12 17 March 2008 Original
________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 3 of 12 ENGINEERING REPORT NO. 32767-5
TEST DATES: Start: 2/24/2006 Completion: 3/7/2006
ENVIRON TEST NO.: 32767-5
PREPARED FOR:
WAVETRONIX LLC 380 SOUTH TECHNOLOGY CT. LINDON, UT 84042 ATTN: Mr. Don Christensen
PURCHASE ORDER NO.: 10981 PURCHASE DATE: 2/15/2006
GASKET AGING TEST 1.0 ABSTRACT
1.1 Object
Subject the supplied Gasket Material to the Gasket Aging Test outlined in NEMA 250, Section 5.14.1, as requested in Wavetronix LLC Purchase Order No. 10981, dated February 15, 2006.
1.2 Conclusions
On completion of testing, tensile strength values are greater than 75% of initial values. On average, elongation values are greater than 60% of initial values. Therefore, the test material samples were determined to have passed the requirements of NEMA 250, Section 5.14.
2.0 UNIT(S) TESTED
MANUFACTURER: WAVETRONIX LLC
DEVICE: Gasket Material for IQ2 Enclosures
MODEL/PART NO.: Untreated Samples Treated Samples
SERIAL NO.: Designated as 1, 2, 3, and 4 Designated as 5, 6, 7, and 8
The results of this test apply only to the units identified in this Engineering Report by device identifier and model / part number, or serial number.
________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 4 of 12 ENGINEERING REPORT NO. 32767-5
3.0 TEST REQUESTED
Subject the test samples to the Gasket Aging Test outlined in NEMA 250, Section 5.14.1, as follows: Gasket material used in a Type 2, 3, 3R, 3 RX, 3S, 3 SX 4, 4X, 5, 6, 6P, 12, 12K, or 13 enclosure shall be of such quality that test samples subjected to a temperature of 69° to 70°C (156 - 158°F) in circulating air for 168 hours have a tensile strength of not less than 75% and an elongation of not less than 60% of values determined for unaged test samples.
4.0 INSTRUMENTATION, PROCEDURE AND RESULTS
4.1 Instrumentation
All instrumentation is calibrated regularly by instruments directly traceable to the National Institute of Standards and Technology, and in accordance with MIL-I-45208A, ANSI/NCSL Z540-1-1994 and ISO/IEC 17025: 1999.
Equi
pmen
t Num
ber
Des
crip
tion
Man
ufac
ture
r
Mod
el N
umbe
r
Last
Cal
ibra
tion
Due
Cal
ibra
tion
Ran
ge
200-145 Temperature Controller
Watlow 982 8/29/2005 8/29/2007 -328º to +750ºF
200-174 Temperature Chart
Recorder
Partlow MRC 7000 12/12/2005 6/12/2006 -150º to +350ºF
500-034 Temperature Chamber
Tenney BTC-100350 N/A N/A -80º to +350ºF
740-065 Universal Testing Machine
Instron 4502 7/25/2005 1/25/2007 0 to 2250 lbs
________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 5 of 12 ENGINEERING REPORT NO. 32767-5
4.2 Procedure
The test samples were placed inside the temperature chamber and subjected to a temperature of 70°C for a period of 168 hours. The samples were then stabilized at ambient conditions. The aged gasket and an unaged gasket were then subjected to a tensile test. Figure No. 1 depicts a temperature chart showing chamber temperature during a typical 24-hour period of exposure. Figure Nos. 2 through 5 include graphic and print-out test data. Photograph Nos. 1 and 2 provide views of the test setup.
4.3 Results
On completion of testing, tensile strength values are greater than 75% of initial values. On average, elongation values are greater than 60% of initial values. Therefore, the test material samples were determined to have passed the requirements of NEMA 250, Section 5.14.
________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 6 of 12 ENGINEERING REPORT NO. 32767-5
Figure No. 1: Temperature chart (°F) showing chamber temperature during a typical 24-hour period of exposure.
________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 7 of 12 ENGINEERING REPORT NO. 32767-5
Figure No. 2: Displacement data, non-aged samples.
________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 8 of 12 ENGINEERING REPORT NO. 32767-5
Figure No. 3: Test data, non-aged samples.
________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 9 of 12 ENGINEERING REPORT NO. 32767-5
Figure No. 4: Displacement data, aged samples.
________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 10 of 12 ENGINEERING REPORT NO. 32767-5
Figure No. 5: Test data, aged samples.
________________________________________________________________________________________________________ ENVIRON LABORATORIES LLC Page 11 of 12 ENGINEERING REPORT NO. 32767-5
Photograph No. 1: View of test sample ready for tensile test.