  • © Blue Energy Technologies

    Represented by:

    SMART Venturi Steam Traps

  • © Blue Energy Technologies

    Who we are?

    We are designers and manufacturers of:

    SMART Venturi Steam Traps SMART Valves SMART PreCooling System.

    2

  • © Blue Energy Technologies

    3

    A range of complete stainless steel Venturi Steam Traps with no moving parts, suitable for all steam trapping applications

    Size ½” to 6” with capacity up to 220 000lb/hr

    SMART Venturi Steam Traps

  • © Blue Energy Technologies

    4

    SMART SVT™ Model Dual Strainer

    in-line maintenance System in Venturi Steam Trap

    Complete 316 (ASTM CF3M) investment cast construction

    Easily accessible insert and strainers

    20 year mechanical and performance guarantee

  • © Blue Energy Technologies

    5

    SMART SVT™ Operation

    Flow is through primary strainer Up through inlet port Through secondary strainer Through opening and Venturi Exit to condensate return

    system

  • © Blue Energy Technologies

    6

    SMART SVT™ Operation Flash steam occurs naturally

    after a trap due to the pressure drop At 140 PSI, flash steam = 18%. Density (ρcondensate @ 140psi) = 55 lb/ft

    3

    Density (ρsteam @ 140psi) = 0.35 lb/ft3

    Steam is 155 times less dense (0.6%) as condensate

    Steam restriction by means of: The flash steam expansion in

    Venturi creates back pressure Large change in density results in

    minimal steam flow

  • © Blue Energy Technologies

    Simple Comparison

    Mechanical steam trap

    Can fail open = expensive steam loss

    Moving parts = maintenance

    Moving parts = spare parts inventory

    Water hammer = damage

    Lifespan = 3 - 5 years

    Warranty = 1 year

    SMART Venturi Steam Trap

    Cannot fail open = no steam loss

    No moving parts = minimal maintenance

    No moving parts = no spare parts

    No Water hammer = no damage

    Lifespan = 20 - 30 years

    Warranty = 20 years7

  • © Blue Energy Technologies

    8

    Benefits of SMART Venturi Steam Traps

    No moving parts

    Can be custom built large capacity up to 100 000 kg/h

    Cannot fail Open Guaranteed for 20 years

    Complete stainless steel construction

    No spare parts required

    No steam leakage

    Handles varying and constant loads Ratio 10:1

    Easily handles and resolves water hammer problems

  • © Blue Energy Technologies

    9

    Minimal Maintenance

    Automatic air venting at start-up

    Operates on “constant discharge” principle

    Perfect operation in vertical or horizontal installation

    Reduced steam requirements reduced CO2 emissions

    Decreased Make-Up water expenses

    Benefits of SMART Venturi Steam Traps

  • © Blue Energy Technologies

    10

    Applications

    Steam Main Line Drainage Tracer Lines Cooking Pots Sterilizers Autoclaves Batch and Continuous Process Applications Heat Exchangers Control Valve Applications Evaporators Reboilers Boiler Water Preheat Coils

  • © Blue Energy Technologies

    11

    Pipeline Ancillaries For Reliable Steam SystemsBellows sealed Globe valves Key benefits:• Bellows sealed design eliminates emissions for improved energy efficiency.• Maintenance free giving long life and low cost of ownership.• Unaffected by vibration and will operate over a wide range of pressures and temperatures

    Ball valvesKey features and benefits:• Manufactured to high specification providing reliable tight shut-off and less maintenance.• Wide range of sizes, materials and body design option • Precision design providing compact valves.• Unrestricted flow allowing low pressure drop and high capacity.• Corrosion resistant bodies ensuring long life.

    Check Valves Pipeline sizes: up to DN250Types Pressures: class 150 up to class 2500Wafer Disc, Split Disc, Swing Body material: forged , cast steel , stainless steel.Lift Check Valves Connections: screwed, flanged, sanitary clamp, butt weld or butt weld

    Y strainer

  • © Blue Energy Technologies

    12

    Clients That Use SMART Venturi Steam TrapsExxonMobil Chemical Plant:Heat exchanger applications:

    1) Design pressure: 9700KPag (1400PSI)2) Design Temperature: 268degC 514degF3) Condensate Loads: dependent on production rate, the maximum around 60 000 PPH flow rate and minimum 8000 PPH

  • © Blue Energy Technologies

    13

    Clients That Use SMART Venturi Steam Traps

    ExxonMobil Chemical Plant:Heat exchanger applications:

  • © Blue Energy Technologies

    14

    Clients That Use SMART Venturi Steam Traps

    ARKEMA:Heat exchanger application:

    Before:

  • © Blue Energy Technologies

    15

    Clients That Use SMART Venturi Steam Traps

    ARKEMA:Heat exchanger applications:

    After installation:

  • © Blue Energy Technologies

    16

    Clients That Use SMART Venturi Steam Traps

    IFF (International Flavors & Fragrances):Reboiler applications :

    1) Variable load applications in reboilers

  • © Blue Energy Technologies

    17

    Clients That Use SMART Venturi Steam Traps

    KEMIRA Water SolutionsWater Boiler Application: Heat up 20 800 gallons water from 80F to 160F and then after maintain this temperature and reheat the new batch as it’s supplied. Capacity of the trap up to 32 000 PPH

    Heat exchanger with installed SMART Steam trap The size of water tank

  • © Blue Energy Technologies

    18

    Clients That Use SMART Venturi Steam Traps

    J.R. Simplot CompanyPrevious steam traps two units 2.5” flanged, ½” orificePressure differential 357 psiCapacity at that ∆P is 35,000 PPH for each steam trap

    A capacity of at least 50,000 PPH for a single trap.

    Reboiler application converted from 2 mechanical steam traps to one SMART Steam Trap

    SMART Steam Trap Set

  • © Blue Energy Technologies

    19

    Venturi Steam Trap – Functional Laboratory Study done for NICOR GAS and SOCAL GAS, Emerging Technology Programs Lead Study.

    Prepared by Gas Technology Institute (“GTI”)

    The objective of the functional testing was to:1) Validate venturi steam traps’ performance at different pressures2) Validate venturi steam traps’ performance at different condensate loads

    Results:The laboratory study captured ambient temperature and pressure, steam supply temperature and pressure, and calorimeter initial temperature, final temperature, initial weight, and final weight data. These parameters were collected for 134 test trials.

    Experimental data have demonstrated the ability of venturi orifice steam traps to discharge varying condensate loads safely across a range of steam pressures, in line with industry requirements. Even when testing outside the specified operational range of the venturi orifice traps, venturi traps were found to operate effectively, discharging condensate with measured steam loss values comparable to mechanical steam traps, within experimental error.

    BET Smart Steam Tarps were tested at this study

  • © Blue Energy Technologies

    20

    Some of Clients That Use SMART Steam Tarps

  • © Blue Energy Technologies

    21