38
Smart CID Release Notes Version 4.2 Abstract This document is intended for Pre-Sales, Account Managers, Integration Center personnel, and Solution Architects who are involved in creating Customer Intent Documents (CIDs) for HPE ConvergedSystems. Published: December 2017 Edition: 1

Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Embed Size (px)

Citation preview

Page 1: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Smart CID Release Notes

Version 4.2

AbstractThis document is intended for Pre-Sales, Account Managers, Integration Center personnel, and Solution Architects who are involved in creating Customer Intent Documents (CIDs) for HPE ConvergedSystems.

Published: December 2017

Edition: 1

Page 2: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Copyright Notices© Copyright 2017, Hewlett-Packard Enterprise Development Company, L.P.

Confidential computer software. Valid license from HPE required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license.

The information contained herein is subject to change without notice. The only warranties for HPE products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HPE shall not be liable for technical or editorial errors or omissions contained herein.

Trademark NoticesRed Hat® is a registered trademarks of Red Hat, Inc.

SUSE® is a registered trademark of SUSE Linux AG.

SAP HANA® is a registered trademark of SAP AG.

VMware® is a registered trademark of VMware, Inc. in the United States and/or other jurisdictions.

vSphere® is a registered trademark of VMware, Inc. in the United States and/or other jurisdictions.

Microsoft® is a registered trademark of Microsoft Corporation in the United States and other countries.

Hyper-V® is a registered trademark of Microsoft Corporation in the United States and other countries.

vCenter™ is a trademark of VMware, Inc. in the United States and/or other jurisdictions.

Intel® is a trademark of Intel Corporation in the U.S. and other countries.

Chrome™ is a registered trademark of Google Inc.

Microsoft® Internet Explorer® are registered trademarks of the Microsoft Corporation.

Page 3: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Table of Contents

1 HPE Smart CID v4.2 Release Notes ..................................................................................................................................... 1

Features ..........................................................................................................................................................................................................2

Browser compatibility .............................................................................................................................................................................3

Systems supported .................................................................................................................................................................................. 4

HPE ConvergedSystem 500 for SAP HANA ....................................................................................................................... 4

Operating systems and HANA revisions for HPE CS500 v5.0 ............................................................................... 6

HPE ConvergedSystem 900 for SAP HANA ........................................................................................................................7

Operating systems and HANA revisions for HPE CS900 v4.0 .............................................................................. 8

HPE ConvergedSystem 700 for Virtualization v2.0 ....................................................................................................... 8

HPE ConvergedSystem 700 for Virtualization v2.5+ November 2017 ................................................................. 8

What’s new in this version ................................................................................................................................................................... 9

New features in CS500 for SAP HANA .................................................................................................................................. 9

New features in CS900 for SAP HANA ................................................................................................................................ 10

New features in CS700 for Virtualization ........................................................................................................................... 10

General Notes ............................................................................................................................................................................................ 11

Notes for CS500 and CS900 ....................................................................................................................................................... 11

Notes for CS700 for Virtualization .......................................................................................................................................... 11

Fixes in Smart CID v4.1 ....................................................................................................................................................................12

Issues and Workarounds .....................................................................................................................................................................12

Issues and Workarounds - CS700 for Virtualization ...................................................................................................12

Issues and Workarounds - OfflineCID ..................................................................................................................................12

Smart CID Support ..................................................................................................................................................................................13

Email Support .......................................................................................................................................................................................13

Smart CID documentation .............................................................................................................................................................13

2 New features and fixes in previous releases .............................................................................................................. 15

New features in previous releases .................................................................................................................................................15

What’s new in Smart CID v4.1 ......................................................................................................................................................15

New features in CS500 for SAP HANA ...............................................................................................................................15

What’s new in Smart CID v4.0 .....................................................................................................................................................15

What’s new in Smart CID v3.1 ..................................................................................................................................................... 16

Page 4: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

New features in CS900 for SAP HANA ................................................................................................................................ 16

What’s new in Smart CID v3.0 .................................................................................................................................................... 16

New features in CS500 for SAP HANA .................................................................................................................................17

New features in CS900 for SAP HANA .................................................................................................................................17

New features in CS700 for Virtualization ............................................................................................................................17

What’s new in Smart CID v2.3 ..................................................................................................................................................... 18

New features in CS500 for SAP HANA ................................................................................................................................ 18

New features in CS900 for SAP HANA ................................................................................................................................ 18

What’s new in Smart CID v2.2.2 ................................................................................................................................................. 18

New features in CS500 for SAP HANA ................................................................................................................................ 19

What’s new in Smart CID v2.2.1 .................................................................................................................................................. 19

New features in CS700 for Virtualization ........................................................................................................................... 19

New features in CS500 for SAP HANA ................................................................................................................................ 19

New features in CS900 for SAP HANA ............................................................................................................................... 20

What’s new in Smart CID v2.2 .................................................................................................................................................... 20

New features in CS700 for Virtualization ........................................................................................................................ 20

New features in CS 500 for SAP HANA .............................................................................................................................21

New features in CS 900 for SAP HANA .............................................................................................................................21

New features in Smart CID v2.1 ..................................................................................................................................................21

New features in CS500 for SAP HANA ..............................................................................................................................22

New features in CS900 for SAP HANA ..............................................................................................................................22

New features in Smart CID v2.0 ................................................................................................................................................23

What’s new in CS500 and CS900 ..........................................................................................................................................23

New features in Smart CID v.1.2.1 .............................................................................................................................................24

New Features in Smart CID v1.2 ................................................................................................................................................24

New Features in Smart CID v1.1.2 .............................................................................................................................................24

New Features in Smart CID v1.1.1 ..............................................................................................................................................25

New Features in Smart CID v1.1 .................................................................................................................................................25

New Features in Smart CID v1.0.2 ............................................................................................................................................26

New Features in Smart CID v1.0.1 ............................................................................................................................................26

Fixes in Previous Releases ................................................................................................................................................................26

Fixes in Smart CID v4.0 ..................................................................................................................................................................26

Fixes in CS500 and CS900 for SAP HANA ........................................................................................................................26

Page 5: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Fixes in Smart CID v3.1 ...................................................................................................................................................................26

Fixes in CS700 for Virtualization .............................................................................................................................................26

Fixes in CS500 and CS900 for SAP HANA ........................................................................................................................27

Fixes in Smart CID v3.0 ..................................................................................................................................................................27

Fixes in CS500 and CS900 for SAP HANA ........................................................................................................................27

Fixes in CS700 for Virtualization .............................................................................................................................................27

Fixes in Smart CID v2.3 ...................................................................................................................................................................27

Fixes in CS500 and CS900 for SAP HANA ........................................................................................................................27

Fixes in CS700 for Virtualization .............................................................................................................................................28

Fixes in Smart CID v2.2.2 ...............................................................................................................................................................28

Fixes in CS 700 for Virtualization ..........................................................................................................................................28

Fixes in CS500 and CS900 for SAP HANA ......................................................................................................................28

Fixes in Smart CID v2.2.1 ................................................................................................................................................................28

Fixes in CS 700 for Virtualization ..........................................................................................................................................28

Fixes in CS500 and CS900 for SAP HANA ......................................................................................................................29

Fixes in Smart CID v2.2 ...................................................................................................................................................................29

Fixes in CS 700 for Virtualization ..........................................................................................................................................29

Fixes in CS500 and CS900 for SAP HANA ..................................................................................................................... 30

Fixes in Smart CID v2.1 .................................................................................................................................................................. 30

Fixes in CS500 and CS900 for SAP HANA ..................................................................................................................... 30

Fixes in Smart CID v2.0 ................................................................................................................................................................. 30

Fixes in CS500 and CS900 for SAP HANA ..................................................................................................................... 30

Fixes in Smart CID v1.2.1 .................................................................................................................................................................31

Fixes in Smart CID v1.2 ....................................................................................................................................................................31

Fixes in Smart CID v1.1.2 ................................................................................................................................................................32

Fixes in Smart CID v1.1.1 .................................................................................................................................................................32

Fixes in Smart CID v1.1 ....................................................................................................................................................................33

Fixes in Smart CID v1.0.2 ...............................................................................................................................................................33

Fixes in Smart CID v1.0.1 ................................................................................................................................................................33

Page 6: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

1 HPE Smart CID v4.2 Release Notes New workloads and business demands require infrastructure that is faster and more efficient. Conven-tional IT architecture creates silos and complexity because of multiple products and tools that lack interoperability. HPE ConvergedSystems meets today’s business and IT needs by bringing servers, stor-age, networking and management software together - engineered to work as one single converged sys-tem.

The result is simplified, yet powerful IT that is energy and space efficient, less expensive, and aligns to meet the needs of the business for any workload at any scale. HPE ConvergedSystems are tightly-inte-grated to help reduce deployment errors along with operational and maintenance costs.

When ordering for a custom or pre-configured converged system, HPE Sales, Solution Architects and technical contacts from customers put together a Customer Intent Document (CID) that contains sys-tem requirements and configuration information. This information is used by HPE to build the system according to specifications in the CID.

Smart CID is the web version of CID that allows you to customize and order pre-configured HPE Con-vergedSystems faster and easier. The tool allows you to select a system, select a configuration and enter relevant details and order a custom and pre-configured system.

1

Page 7: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

FeaturesFollowing are the feature highlights:

• Web-based: Smart CID is web-based and can be accessed from a browser. It is a single place to store and retrieve all information instead working with multiple versions shared over email.

• Simplified experience: Smart CID has built-in validations to ensure that the information entered is complete and accurate.

• It provides default values for hostnames, IP addresses and passwords to make the CID process faster and more efficient.

• The inline help is context-aware. It progressively discloses the required information – guiding users to provide the right data in the right field.

• User friendly and intuitive interface: Smart CID’s intuitive and user friendly interface makes it easy to enter all CID information in one place. The interface is similar to other HPE management tools like HPE OneView.

2 Features

Page 8: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Browser compatibilitySmart CID is designed to work on the following browsers:

• Google Chrome (http://www.google.com/chrome/)

• Microsoft Internet Explorer 11 (http://windows.microsoft.com/en-IN/internet-explorer/download-ie)

Browser compatibility 3

Page 9: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Systems supportedSmart CID supports creating CIDs for the following systems:

• HPE ConvergedSystem 500 for SAP HANA (v2.0, v3.0, v4.0, and v5.0)

• HPE ConvergedSystem 900 for SAP HANA (v2.0, v3.0 and v4.0)

• HPE ConvergedSystem 700 for Virtualization v2.0

• HPE ConvergedSystem 700 for Virtualization v2.5 March 2017 release

• HPE ConvergedSystem 700 for Virtualization v2.5+ November 2017 release

• Network Functions Virtualization (NFV)

The following sections detail the supported configuration and classification for each system.

HPE ConvergedSystem 500 for SAP HANAThe following tables list the supported configuration and classification for HPE ConvergedSystem 500 for SAP HANA.

Table 1. HPE ConvergedSystem 500 for SAP HANA v2.0

Configuration Appliance size Classification

Scale up 256 GB

512 GB

1 TB

2 TB

Regular

Dual Purpose

With HPE Serviceguard

Dual Purpose with HPE Serviceguard

Scale out 4 Servers

8 Servers

12 Servers

16 Servers

Granular

Regular

With HPE Serviceguard

Dual Purpose

Dual Purpose with HPE Serviceguard

4 Systems supported

Page 10: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Table 2. HPE ConvergedSystem 500 for SAP HANA v3.0

Configuration Appliance size Classification

Scale up 128 GB

256 GB

384 GB

512 GB

768 GB

1 TB

1.5 TB

2 TB

3 TB

Regular

Dual Purpose

With HPE Serviceguard

Dual Purpose with HPE Serviceguard

Scale out Granular Regular

Dual Purpose

With HPE Serviceguard

Dual Purpose with HPE Serviceguard

Max Regular

Table 3. HPE ConvergedSystem 500 for SAP HANA v4.0

Configuration Appliance size Classification

Scale up 128 GB

256 GB

384 GB

512 GB

768 GB

1 TB

1.5 TB

2 TB

3 TB

4 TB

Regular

Dual Purpose

Scale out Granular Regular

Dual Purpose

Systems supported 5

Page 11: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Operating systems and HANA revisions for HPE CS500 v5.0The following table lists the operating system and supported HANA revisions for HPE ConvergedSys-tem 500 v5.0.

Table 4. HPE ConvergedSystem 500 for SAP HANA v5.0

Configuration DIMM Size

Scale up 8 GB

16 GB

32 GB

64 GB

128 GB

16 GB, 32GB (Mixed DIMM)

Table 5. Operating system and HANA revision

Operating system HANA revision 2.0

SUSE Linux Enterprise Server 12.1 (SLES 12.1) SPS00, SPS01, SPS02

SUSE Linux Enterprise Server 12.2 (SLES 12.2) SPS00, SPS01, SPS02

Red Hat Enterprise Linux 7.2 (RHEL 7.2) SPS00, SPS01, SPS02

Red Hat Enterprise Linux 7.3 (RHEL 7.3) SPS00, SPS01, SPS02

6 Systems supported

Page 12: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

HPE ConvergedSystem 900 for SAP HANAThe following tables list the supported configuration and classification for HPE ConvergedSystem 900 for SAP HANA v2.0, v3.0, and v4.0.

Table 6. HPE ConvergedSystem 900 for SAP HANA v2.0

Configuration Appliance size Classification

Scale up 6 TB

6 TB + 6 TB

12 TB

Regular

Dual Purpose

With HPE Serviceguard

Dual Purpose with HPE Serviceguard

Scale out Isolated CMS in gateway mode

Integrated CMS in gateway mode

Isolated CMS with inte-grated management

Integrated CMS with inte-grated management

Regular

Dual Purpose

With HPE Serviceguard

Dual Purpose with HPE Serviceguard

Table 7. HPE ConvergedSystem 900 for SAP HANA v3.0

Configuration Appliance size Classification

Scale up Custom Regular

With HPE Serviceguard

Dual Purpose

Dual Purpose with HPE Serviceguard

Table 8. HPE ConvergedSystem 900 for SAP HANA v4.0

Configuration Appliance size

Scale up Regular with 2S to 16S

Dual purpose with 2S to 8S

Dual purpose with 2S to 16S

Scale Out Regular

Dual Purpose

Max Scale Out Regular

Dual Purpose

Systems supported 7

Page 13: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Operating systems and HANA revisions for HPE CS900 v4.0The following table lists the operating system and supported HANA revisions for HPE CS900 v4.0.

HPE ConvergedSystem 700 for Virtualization v2.0The following table lists the supported configuration and classification for HPE ConvergedSystem 700 for Virtualization v2.0 and v2.5:.

HPE ConvergedSystem 700 for Virtualization v2.5+ November 2017The following table lists the supported configuration and classification for HPE ConvergedSystem 700 for Virtualization v2.5+ November 2017:.

Table 9. Operating system and HANA revision

Operating system HANA revision 1.0 HANA revision 2.0

SUSE Linux Enterprise Server 12.1 (SLES 12.1) SPS10, SPS11, SPS12 SPS00,SPS01,SPS02

SUSE Linux Enterprise Server 12.2 (SLES 12.2) SPS10, SPS11, SPS12 SPS00,SPS01,SPS02

Red Hat Enterprise Linux 7.2 (RHEL 7.2) SPS10, SPS11, SPS12 SPS00,SPS01,SPS02

Red Hat Enterprise Linux 7.3 (RHEL 7.3) SPS10, SPS11, SPS12 SPS00,SPS01,SPS02

Table 10. HPE ConvergedSystem 700 for Virtualization v2.0 and v2.5 March 2017

Configuration Solution type

Foundation Single rack

Single rack with SAN switch

Multi rack

VMware Single rack

Single rack with SAN switch

Multi rack

Hyper-V Single rack

Single rack with SAN switch

Multi rack

Table 11. HPE ConvergedSystem 700 for Virtualization v2.5+ November 2017

Configuration Solution type

Foundation Single rack

Single rack with SAN switch

Multi rack

VMware Single rack

Single rack with SAN switch

Multi rack

8 Systems supported

Page 14: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

What’s new in this versionThis version of Smart CID has the following features:

• Offline CID, a desktop version of smart CID is introduced to create CIDs in offline mode. It has all the features, rules and validations as Smart CID.

• A new Comment option is added in the Submit for review. It enables a user to provide comments when reviewing in the CID life cycle.

New features in CS500 for SAP HANAThe following new features have been introduced for HPE ConvergedSystem 500 for SAP HANA:

• A new option, Data replication, is added in HANA DB form. It enables a user to select the following:

• Location from primary site and secondary site.

• Replication mode from Sync, Mem-Sync, and Full Sync.

• Operation Mode from Log Reply and Delta Shipping

• A new DIMM size, 128GB, is added for Skylake. It supports the following configuration:

• Processor types: 8176M (2.1GHz) and 8180M (2.5GHz),

• Storage Option: 12 x 3.2TB SSD (RAID-50)

• Memory Type: Uniform DIMM

• CPU Socket: 2S and 4S

• Memory Slots: 24 and 48

• Appliance Memory: Based on the values selected in the Memory slots and Memory slots fields, the value of the Appliance Memory is calculated and displayed. For example, for 2S CPU Socket, Memory Slot is 24, DIMM size is 128GB, and Appliance memory is 3TB.

• A new Memory Type, Mixed DIMM (16GB,32GB), is added for Skylake. It supports the following con-figuration:

• Processor types: 8176 (28Core, 2.1GHz) and 8180 (28Core, 2.5GHz)

• Storage Option: 6(HDD) + 2(SSD) and 13(HDD) + 3(SSD)

• Memory Type: Mixed DIMM

• CPU Socket: 2S and 4S

• Memory Slots: 24 and 48

• Appliance Memory: Based on the values selected in the Memory slots and Memory slots fields, the value of the Appliance Memory is calculated and displayed. For example, for 4S CPU Socket, Memory Slot is 48, DIMM size is 16GB,32GB, and Appliance memory is 1152GB.

• HANA DB information in CS500 is now enhanced and moved to the appliance details section. The HANA DB section is displayed on dashboard only when Hana Installation and OS revision are selected in the appliance details section. This feature is applicable only for active CIDs created previ-ously.

• HPE Smart CID supports RHEL 7.3, SLES 12.2 for Skylake.

• A new option, logreplay readonly, is added in HANA DB for Broadwell.

• A new option, Delta Data Shipping, is added in HANA DB for both Broadwell and Skylake.

What’s new in this version 9

Page 15: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

New features in CS900 for SAP HANA• HPE Smart CID supports RHEL 7.3 for Broadwell.

• HPE Smart CID supports SLES 12.2 for Broadwell.

• HPE Smart CID supports HANA revisions 2.0 SPS01, SPS02 for Broadwell.

New features in CS700 for VirtualizationSmart CID now supports the following new configuration:

• HPE ConvergedSystem CS700 for Virtualization v2.5+ November 2017.

• Foundation Kit with single rack, single rack with SAN switch and multi rack.

• VMware Kit with single rack, single rack with SAN switch and multi rack.

• Following new features have been added in the Storage section:

• Flash Array,

• storage tier type,

• RAID Technology.

10 What’s new in this version

Page 16: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

General Notes• Smart CID does not check the validity of HPE Sales Order number and HPE Sales Quote number.

Ensure that you enter the correct order and quote numbers in HPE Contact Info section.

• HPE Smart CID sends notification mails to customers only when a CID is created or submitted.

Notes for CS500 and CS900The following notes are applicable for HPE ConvergedSystem 500 for SAP HANA and HPE Con-vergedSystem 900 for SAP HANA:

• Super user access displays CIDs from all regions. To view a CID for any region, enter region in the search box.

• For HPE CS500 v4.0, it is mandatory to enter the timezone information in the HANA DB section.

• For HPE CS500 v4.0, primary and secondary virtual IPs cannot be duplicated in the Serviceguard configuration.

• When you update information in Rack Layout (for Granular configuration), ensure that you open and save the Network form again to regenerate default values. Depending on the change, Smart CID may need additional information in the Network section before the CID can be submitted.

• Insight Remote Support (IRS) is not available for HPE CS500 v2.0.

• When ordering for a system that has DR (Data Replication) enabled, enter a valid DR order number in the HANA DB section. This is different from the HPE order number. DR systems need a separate DR order number.

• When setting time zones, ensure that you select the same time zone in the Networking and HANA DB sections.

• In the HANA DB section, the default values for the HANA system is Default. This word is case sen-sitive. Do not change this value.

• In the HANA DB section, when selecting Language, enter a language that SAP HANA installation supports. If you enter a language that is not supported by SAP HANA, the default language, English, will be used.

• In the HANA DB section, only the multi container option is displayed for HANA 2.0.

• In the HANA DB section, do not use the following reserved values when entering SAP HANA SID:

• ADD, ALL, AMD, AND, ANY, ARE, ASC, AUX, AVG, BIT, CDC, COM, CON, DBA, END, EPS, FOR, GET, GID, IBM, INT, KEY, LOG, LPT, MAP, MAX, MIN, MON, NIX, NOT, NUL, OFF, OLD, OMS, OUT, PAD, PRN, RAW, REF, ROW, SAP, SET, SGA, SHG, SID, SQL, SUM, SYS, TMP, TOP, UID, USE, USR, and VAR.

Notes for CS700 for VirtualizationThe following notes are applicable for HPE ConvergedSystem 700 for Virtualization:

• Searching for the string “CS 700 for Virtualization 2.5+ November 2017 release VMware Multi Rack” does not return any result. Use the string “CS 700 for Virtualization” instead to list CS700 configura-tions.

• Validation of duplicate hostnames and IP addresses is not supported in this release. Ensure that you enter unique hostnames and IP addresses in the Network section.

General Notes 11

Page 17: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• When you open the Excel file generated from Summary View, Excel displays an alert related to the file’s extension. This is because Microsoft Excel files have a *.xlsx extension and the Smart CID file has a *.xls extension. Click Yes to open the file. Save the file as <CID-Number>.xlsx.

Fixes in Smart CID v4.1• When submitting a CID for review with lengthy review comments, an error message is displayed.

This issue is now fixed.

Issues and WorkaroundsThis section describes issues and workarounds for HPE Smart CID.

Issue

Smart CID does not display content correctly in non-English browsers.

Workaround

Modify the browser language to English before accessing Smart CID. For Microsoft Internet Explorer, navigate to the Compatibility View Settings section and select the Display intranet sites in Compatibility View check box.

Issue

There is a known compatibility issue with some newer versions of Google Chrome and HPE Smart CID application. Users may experience unresponsive pages or an ‘Aw, Snap!’ message on Google Chrome.

Workaround

HPE recommends you to use Microsoft Internet Explorer until this known issue is fixed.

Issues and Workarounds - CS700 for VirtualizationThis section lists issues and workarounds for HPE ConvergedSystem 700 for Virtualization.

Issue

Microsoft Excel displays an alert when you open the Excel file (<CID-Number.xls>) downloaded from Summary View.

Workaround

Click Yes to open the file and save the file as <CID-Number>.xlsx. The alert is displayed because Microsoft Excel opens files with *.xlsx extension by default. Smart CID exports CID information in the *.xls format.

Issues and Workarounds - OfflineCIDIssue

When the Offline CID URL is entered in Internet browser, https:// is not automatically appended to the URL.

Workaround

Enter complete URL https://localhost:18080/ manually. This issue will be fixed in the next version.

12 Issues and Workarounds

Page 18: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Issue

When MariaDB is already installed and present, the login does not work as expected.

Workaround

Install the MariaDB after login to the Offline CID.

Smart CID Support

Email SupportFor critical issues that need immediate attention, send a mail to [email protected].

Smart CID documentation HPE is committed to providing documentation that meets your needs. To help us improve the docu-mentation, send any errors, suggestions, or comments to CSS Documentation Feedback ([email protected]). Include the document title and version number when submitting your feedback.

The documentation set for this release is available on HP Smart CID website. In addition to this docu-ment, you can find related documents and training material on the Smart CID website:

https://smartcid.itcs.hpe.com/Training/#docs

Smart CID Support 13

Page 19: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

2 New features and fixes in previous releasesThis section lists new features added and fixes in the previous releases.

New features in previous releasesThis section lists new features in the previous releases.

What’s new in Smart CID v4.1This version of Smart CID introduces a new appliance HPE ConvergedSystem 700 for Virtualization v2.5+ November 2017 release.

This version of Smart CID has the following features:

• A new option, Import, is introduced to import CID. To import the CID, complete the following:

• In Start a new CID page, Click Import.

• In the Import CID window, click Choose File, select the file and Import.

New features in CS500 for SAP HANAThe following new features have been introduced for HPE ConvergedSystem 500 for SAP HANA:

• HPE Smart CID supports the Serviceguard classification for HPE ConvergedSystem 500 v5.0 for SAP HANA (Skylake).

• A new option, logreplay readonly, is added in HANA DB for HPE ConvergedSystem 500 v5.0 for SAP HANA (Skylake).

• In HANA DB, validation checks have been added for selecting the correct SPS versions for HPE Con-vergedSystem 500 v5.0 for SAP HANA (Skylake).

• For HPE ConvergedSystem 500 v4.0, Smart CID now allows you to enter file personal related host-name and IP addresses in the Network section.

What’s new in Smart CID v4.0This version of Smart CID introduces a new appliance CS500 for SAP HANA v5.0 (Skylake). This is avail-able in the Scale up configuration in this release.

Customers can choose the following options when ordering for CS500 for SAP HANA v5.0 (Skylake):

• Processor Type

• 8176 (28Core, 2.1GHz)

• 8180 (28Core, 2.5GHz)

• Storage Option

• 6(HDD) + 2(SSD)

• 13(HDD) + 3(SSD)

• CPU Socket

• 2S

New features in previous releases 15

Page 20: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• 4S

• Memory Slots

• 12

• 24

• 48

• DIMM Size

• 8 GB

• 16 GB

• 32 GB

• 64 GB

• Appliance Memory - Based on the values selected in the Memory slots and DIMM size fields, the value of the Appliance Memory is calculated and displayed.

• Enable Virtual Rack - If you do not want to order for a physical rack, select Enable Virtual Rack.

What’s new in Smart CID v3.1This version of Smart CID has the following features:

• Smart CID has moved logging in and authentication for Customers and Partners to HPE Passport.

• A new option, Submit for Review, is introduced to send a CID for review after all the CID details are entered. This option is available on the CID dashboard. To send a CID for review, click Actions and then click Submit for Review.

New features in CS900 for SAP HANAThe following features are introduced for HPE ConvergedSystem 900 for SAP HANA:

• HPE Smart CID supports the installation of HANA DB 2.0 for HPE CS900 for SAP HANA v4.0.

What’s new in Smart CID v3.0This version of Smart CID has the following features:

• Smart CID has added the Logout option for Customers and Partners.

• HPE Smart CID supports the following new configurations:

• HPE ConvergedSystem 900 for SAP HANA v4.0:

• Scale out (Regular and Dual Purpose)

• Max Scale out (Regular and Dual Purpose)

• HPE ConvergedSystem 700 for Virtualization v2.5:

• Foundation Kit (single rack, single rack with SAN switch and multi rack)

• VMware Kit (single rack, single rack with SAN switch and multi rack)

• Hyper-V Kit (single rack, single rack with SAN switch and multi rack)

• HPE Smart CID supports the installation of HANA DB 2.0 for HPE ConvergedSystem 500 for SAP HANA v4.0.

16 New features in previous releases

Page 21: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• HPE Smart CID supports Network Functions Virtualization (NFV).

New features in CS500 for SAP HANAThe following features are introduced for HPE ConvergedSystem 500 for SAP HANA:

• In the output file, IPList.txt, a new column has been added to enter hostnames.

• In HANA DB, validation checks have been added to ensure that there are no duplicate values for SAP ADM and SAP group ID across all instances in a CID.

New features in CS900 for SAP HANAThe following features are introduced for HPE ConvergedSystem 900 for SAP HANA:

• The following optional fields are added in the Appliance Details section:

• Common Timezone

• Domain Name

• Default Gateway IP

• NTP Servers IP1 and NTP Servers IP2

• DNS Servers IP1 and DNS Servers IP2

• For CS900 v4.0, SAP defined hostname restrictions have been added for some HANA hostname inputs.

• In the Common Information section, validation checks have been added for Domain Names.

• The Memory Size section is moved from the Network section to the Partition Information section.

New features in CS700 for VirtualizationThe following new features are introduced for HPE ConvergedSystem 700 v2.5 for Virtualization:

• The following options are added in the Network Component Related Questions section in Order Questionnaire:

• HPE 5940

• Cisco N9K

• Smart CID allows the addition of a single array for any number of enclosures. For Deal Specific Requirements (DSRs), two arrays can be selected for four or less enclosures.

• The values for network adapters are updated for all VMs.

• If Virtual Service Router (VSR) is set to Yes, the values for the network adapter 1 and network adapter 2 are updated to Solution management network and DC management network.

• If VSR is set to No, the values for the network adapter 1 and network adapter 2 fields are updated to DC Management Network and Deployment Network. Also, the value for network adapter 2 field in VCSA and PSC VMs is updated to Not Applicable.

• Rack Layout does not show the HPE ProLiant WS460c Gen9 w/PCI Expansion K2 option and the HPE ProLiant WS460c Gen9 w/PCI Expansion K1 option.

New features in previous releases 17

Page 22: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• Added options to select QSPF+ for the DataCenter Uplink Media field and 40Gbe for the DataCenter Uplink Port Speed field in the Connectivity Information to Customer’s Network section. These options are only displayed when HPE switch is selected in the Order Questionnaire section.

• The Passwords section is updated with additional passwords for CloudSystem 10 Deployer, Simple Network Management Protocol (SNMP) Authentication and SNMP Privacy.

• OV4vc appliance values are added in the Summary view, Excel file and the XML file.

• Option to reserve storage array ports for implementation of Remote Copy Functionality is added in this release. This is available in the Order Questionnaire in the Storage Related Questions section

What’s new in Smart CID v2.3This version of Smart CID has the following features:

• Support for the following configuration:

• HPE ConvergedSystem 500 for SAP HANA v4.0 - Max Scale Out (Regular and Dual Purpose)

• A new field on the Profile CIDs page to provide a description for each CID. This field is used to enter specific information for each CID. It can be modified throughout the entire life cycle even after a CID is submitted.

• Entering the HPE Passport ID number in the Customer Info section is optional.

New features in CS500 for SAP HANAThe following new features have been introduced for HPE ConvergedSystem 500 for SAP HANA:

• For HPE ConvergedSystem 500 v4.0 Scale Out configuration, the config checker output file is added to support the Broadwell configuration. A link is provided to access the config checker output file for all CIDs.

• For HPE ConvergedSystem 500 v4.0 Scale Up configuration, the TAR output file is updated to sup-port the Broadwell configuration.

New features in CS900 for SAP HANAThe following new features have been introduced for HPE ConvergedSystem 900 for SAP HANA:

• When a CID is submitted, Smart CID now checks the output XML file against the HPE Con-vergedSystem 900 schema XML Schema Definition (XSD) values to ensure that the generated out-put file is valid. This is useful when the system is configured at the Integration Centers.

What’s new in Smart CID v2.2.2This version of Smart CID has the following features:

• HPE Smart CID now supports the option to get customer information from the database for the Cus-tomer Info and HPE Contact sections. If the customer information and contact details are entered for any other CID, they are available as a drop-down menu. You can select the option and the entire cus-tomer contact information section is filled with related data.

18 New features in previous releases

Page 23: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• The Smart CID dashboard is changed for HPE ConvergedSystem 500 and HPE ConvergedSystem 900. A new section called Appliance Details has been introduced. The Appliance Details section con-tains details about the appliance. In the Appliance details section, you can also use the appliance size option to specify the size of the appliance at any time.

• The HPE Passport ID number is introduced in the Customer Info section for HPE ConvergedSystem 500 and HPE ConvergedSystem 900.

• Three additional contact details are provided in the Customer Info and HPE Contact sections for HPE ConvergedSystem 500 and HPE ConvergedSystem 900.

• The Serviceguard and Dual Purpose configurations are moved to the HANA DB section for HPE ConvergedSystem 500. Earlier they were available in the Creating a new CID menu option.

• Device listing is reorganized in the Network section for HPE ConvergedSystem 500.

New features in CS500 for SAP HANA• For HPE Converged System 500 v4.0, Quorum section for four socket system is enabled in the Net-

work section.

• HPE Smart CID now provides the On Site Installation option for Serviceguard configuration in HPE ConvergedSystem 500 v4.0.

What’s new in Smart CID v2.2.1This version of Smart CID has the following features:

• The Deal Specific Requirements (DSR) details are now visible to HPE users only.

New features in CS700 for Virtualization• The HPE Proliant BL660c Gen9 Server blade type is added to Rack Layout.

New features in CS500 for SAP HANA• HPE Smart CID now supports the Serviceguard and Dual Purpose with HPE Serviceguard classifica-

tions for HPE ConvergedSystem 500 v4.0.

• The HANA database section now provides an option to replicate primary HANA system for Service-guard HA/DR failover purpose. Select Yes if secondary clustered HANA replication is required. You must manually enter the primary CID number. Also, enter the instance name and secondary instance details from the corresponding instance of the primary CID.

• For HPE ConvergedSystem 500, SAP HANA database shows Operating System distribution subver-sions for SLES or RHEL.

• Entering details in the Management network section is optional.

• HPE Smart CID provides an option to select HANA DB or Multitenant Database Containers (MDCs) for HPE ConvergedSystem 500 v4.0.

New features in previous releases 19

Page 24: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

New features in CS900 for SAP HANA• HPE Smart CID now displays Extra 3PAR and the 3PAR Remote Access sections for HPE Con-

vergedSystem 900 v3.0 for Dual Purpose classification.

• HPE Smart CID now supports the Dual Purpose and Dual Purpose with HPE Serviceguard classifica-tions for HPE ConvergedSystem 900 v3.0.

• HPE Smart CID now supports the HPE Serviceguard classification for HPE ConvergedSystem 900 v4.0.

What’s new in Smart CID v2.2This version of Smart CID has the following new features:

• Smart CID now supports Deal Specific Requirements (DSRs). In the Customer Info section, a field has been introduced to identify a deal specific CID. An option to enter a DSR ID is also available. Profile CIDs page, that lists all CIDs, now has an additional Yes/No entry for DSRs. DSR fields are available for all ConvergedSystem solutions (CS500, CS900 and CS700).

• On the Profile CIDs page, a new feature has been introduced to sort the list of CIDs. Click the column header to list data either alphabetically or numerically in the ascending or descending order.

Note: Some users may not view a newly created CID when sorting the list of CIDs on Profile CIDs. See “Issues and Workarounds” on page 12. for a work around.

New features in CS700 for VirtualizationThe following new features have been introduced for HPE ConvergedSystem 700 for Virtualization 2.0:

• SAN switch support has been introduced for single rack systems. This option enables the Storage module to be integrated with the single rack solution.

• Support for Broadwell processor has been introduced in this release.

• Option to specify the primary Power Distribution Unit (PDU) for the compute rack has been intro-duced in this release.

Note: All these options are available in the Order Questionnaire in the Hardware Related Questions sec-tion. Depending on your selection in the questionnaire, Smart CID displays respective fields in the Network and CloudSystem sections.

• Option to select a physical service processor or a virtual service processor has been introduced in this release. This is available in the Order Questionnaire in the Storage Related Questions section.

• The Passwords section has been updated with additional passwords for ESXi Management hosts and Virtualization hosts root accounts. All default passwords are auto-generated. You can edit the passwords to customize it. However, the updated password does not work when validating the solu-tion at the Integration Center, the original default password will be used for validation.

• In the Storage section, option to specify proxy server details has been introduced. You can specify the following information for the proxy server in the Storage section. This information is optional.

• IP address

• Port

• Username

20 New features in previous releases

Page 25: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• Password

• Installation of 3PAR Secure Service Policy Manager

• A new section called Network has been added for Foundation systems. This section allows you to specify the following information:

• Datacenter Uplink Device Manufacturer/Model

• Datacenter Uplink Media

• Datacenter Uplink Port Speed

• Number of Uplink Connections

New features in CS 500 for SAP HANAThe following new features have been introduced for HPE ConvergedSystem 500 for SAP HANA:

• Enhanced support for Multitenant Container Databases (MCDs). The Multitenant container data-base user interface is now enhanced to support separate OS user name, group name and group number for each tenant database.

• HTML report - All information of the CID is now available in an HTML file. Download the report from the Output Files section.

New features in CS 900 for SAP HANAThe following new features have been introduced for HPE ConvergedSystem 900 for SAP HANA:

• Cloning for CS900 v4.0 is now available in Smart CID.

• The following new fields have been introduced in the Network Common Information section for CS900 v4.0:

• Daylight Saving Time (DST) (optional) - Select this option to set the DST offset for applicable devices. To enable DST, select Yes, and specify the following:

• DST name

• Start date and time

• End date and time

• DST offset time (in hours)

• Domain name (optional)

• Default gateway IP address (optional)

• NTP server IP address (optional)

• DNS server IP address (optional)

• HTML report - All information of the CID is now available in an HTML file. Download the report from the Output Files section.

• Smart CID allows you to add routes to the existing network. A maximum of 32 routes can be added to the existing network.

New features in Smart CID v2.1This version of Smart CID has the following new features:

New features in previous releases 21

Page 26: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• Smart CID now supports the following new configurations:

• HPE ConvergedSystem 500 for SAP HANA v4.0

• Scale up (Regular and Dual Purpose)

• Scale out (Regular and Dual Purpose)

• HPE ConvergedSystem 900 for SAP HANA v4.0

• Scale up

• Custom (Regular)

• 8 Sockets (Dual Purpose)

• 16 Sockets (Dual Purpose)

Details of new features in each system is given in the following sections.

New features in CS500 for SAP HANAThe following new features have been introduced for HPE ConvergedSystem 500 for SAP HANA:

• A new option has been added to support the following:

• 2 sockets/2 TB

• 4 sockets/4 TB

• Support for Multitenant Container Databases (MCDs)

• Smart CID now allows ordering for systems with SAP HANA multitenant container database option. To specify multitenant container database in Smart CID, click Yes for the multitenant database question in HANA DB section. In the MCD section, enter for multitenant container database.

• Number of multitenant container databases

• Isolation level (high or low)

• Option to enter operating system, user groups, and database names.

• Support to order for mix CPUs. Smart CID now allows you to specify if both processors (v2.0 and v3.0) for the CID and solution. This option is available in the HANA DB section.

• In Customer Contact section, you can enter multiple email IDs separated by commas. You can enter up to 5 email IDs in the following format:

[email protected],[email protected],[email protected]

• Memory calculator - The HANA DB section now has a memory calculator to help users to calculate values for memory utilization when entering HANA DB information. The memory calculator is avail-able in HANA DB section.

New features in CS900 for SAP HANAThe following new features have been introduced for HPE ConvergedSystem 900 for SAP HANA:

• HPE ConvergedSystem 900 for SAP HANA v4.0 supports Scale up configuration only. It supports Dual Purpose classification only if the classification is 8 sockets or 16 sockets.

• By default, Smart CID auto-generates 12 default networks with default values. Smart CID allows you to customize each of default networks and if required, edit the default values for each network. You

22 New features in previous releases

Page 27: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

can customize, rename or update any network. The following is a list of values that are auto-gener-ated by Smart CID and can be customized based on customer environment:

• Network name

• VLAN ID

• VLAN name

• IPv4 network prefix (IP address)

• Subnet CIDR

• Uplink Interface

• Smart CID allows you to add new networks or remove an existing default network that is not appli-cable. HPE ConvergedSystem 900 can support up to 16 customizable networks.

• HANA DB section for CS900 now allows you to enter additional databases depending on the num-ber of partitions.

New features in Smart CID v2.0• Smart CID now supports HPE ConvergedSystem 700 for Virtualization. The following solution

types are available for HPE CS700:

• Foundation Kit (single rack and Multi rack)

• VMware Kit (single rack and multi rack)

• Hyper-V Kit (single rack and multi rack)

• HTTPS - HTTPS has been implemented for Smart CID.

• Upload a file - A new option to attach or upload files has been introduced in this version. Files can be uploaded from the navigation panel. See the Smart CID User Guide for detailed instructions.

• Re-open a submitted CID – A new option has been introduced to change the status from Submit-ted to Active. This option is available only for users with administrative privileges. This is available on the CID dashboard in the Actions link. Send an email to [email protected] for adminis-trative privileges.

• Archive a submitted CID – A new option has been introduced to archive a submitted CID. This option is available in the Actions link. Archiving a CID removes the CID from the Profiles CIDs list to the Archived CID list.

• Search – Search has been implemented in this version. This is available on the Profile CID page. Users can search for CIDs using search strings like CID number, customer name, and solution name.

What’s new in CS500 and CS900The following new features have been introduced for in HPE ConvergedSystem 500 for SAP HANA and HPE ConvergedSystem 900 for SAP HANA sections in Smart CID:

• Option to access output files has changed. Output files and HTML report are now available from the navigation panel. In addition to the auto generated files, a zip file, <CID_Number>.zip is also created that has all the files in it.

• A new option to select a virtual rack is introduced in Rack Layout for CS500. This option is recom-mended when customers do not want a physical rack.

• A new option to specify public NTP server addresses is introduced in the Common Network Infor-mation section.

New features in previous releases 23

Page 28: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• A new question to select instance pre-installation has been added in SAP HANA. After you select the OS distribution and the SAP HANA revision, you can specify if you need the instance pre-instal-lation.

• HTML report and the output configuration files are now available in the navigation panel. These are available only after the CID is submitted.

• Extra 3PAR count and information is now available in the dashboard.

New features in Smart CID v.1.2.1• Smart CID now supports the following new configurations:

• RHEL 6.6 is now supported for HP ConvergedSystem CS 500 v3.0 Dual Purpose systems.

• HPE Serviceguard is now supported for HPE ConvergedSystem CS 500 v3.0 Dual Purpose sys-tems.

• RHEL 6.6 is now supported for HPE ConvergedSystem CS 900 v3.0 (Gen 3.0).

• HPE Serviceguard is now supported for HPE ConvergedSystem CS 900 v3.0 (Gen 3.0).

• Smart CID now supports SPS11 HANA revision for HPE ConvergedSystem CS 500 v3.0 and HPE ConvergedSystem CS 900 v3.0.

• A new option for maximum (Max) scale out has been added to HPE ConvergedSystem CS 500 v3.0.

• A new option called Partial Save has been introduced in the Network section. This option allows users to save partial information in the Network section and update other information later.

• DHCP is now enabled for iLO/OA network. Selecting this option allows dynamic IP addresses for all devices in the iLO/OA network. When this option is selected, the IP address fields for Subnet, Net-mask and Gateway in iLO/OA network are disabled.

• A new option to configure SNMP has been introduced in the Insight Remote Support (IRS) section.

• Links to documentation and training are now included in the notification emails.

• After a CID is submitted, a link to the HTML report is now available on the dashboard.

New Features in Smart CID v1.2• Smart CID now supports HPE ConvergedSystem CS 900 v3.0 (Gen 3.0) Scale up configuration.

• Smart CID now supports Red Hat Enterprise Linux (RHEL 6.6) for HPE ConvergedSystem 900 v3.0 and HPE ConvergedSystem CS 500 Scale out v3.0 Dual Purpose system.

• Additional networks are added for HPE ConvergedSystem CS 900 v3.0.

• A new section called Partition Information is added to the dashboard for HPE ConvergedSystem CS 900 v3.0. This section allows you to select the blades and enter the number of partitions.

• Smart CID now supports SPS10 HANA revision.

New Features in Smart CID v1.1.2• Smart CID now supports the following configurations:

• HPE ConvergedSystem CS 500 v2.0 (Gen 2) Scale up with HPE Serviceguard.

• HPE ConvergedSystem CS 500 v2.0 (Gen 2) Scale up Dual Purpose with HPE Serviceguard

• HPE ConvergedSystem CS 500 v3.0 (Gen 3) Scale up with HPE Serviceguard

24 New features in previous releases

Page 29: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• HPE ConvergedSystem CS 500 v3.0 (Gen 3) Scale up Dual Purpose with HPE Serviceguard

• HPE ConvergedSystem CS 500 v3.0 (Gen 3) Scale out Dual Purpose

• The Profile CIDs page now lists the age of the CID.

• Age of active CIDs is the number of days the CID is in active status.

• Age of submitted CIDs is the number of days after it was submitted.

New Features in Smart CID v1.1.1• Smart CID now supports Dual purpose configuration for HPE ConvergedSystem CS 500 v3.0.

• RHEL 6.6 is now supported for HPE ConvergedSystem CS 500 v3.0 scale out classification.

• A new option has been added to enter hostnames and IP addresses for CMS (Central Management Server) and CMC (Central Management Console) in the iLO/OA network section. This option is avail-able only for scale out systems.

1. Click iLO/OA network in the Network section.

2. Click Hardware Devices (components) Configuration.

3. Enter hostname and IP address for CMS and CMC servers.

• In HANA DB, validation and notification for maximum and minimum values of memory utilization has been added.

• In Networking, it is now mandatory to enter iLO/OA network information before submitting the CID. The Not Applicable option is now changed to Fill Later.

• When submitting a CID, an option to enter comments has been added. You can enter special instruc-tions and comments related to the CID in the comments field.

• After submitting a CID, an additional file, IPList.txt is generated along with the configuration files. This file contains all the host names and IP addresses in that CID.

• IP addresses and hostnames of DNS servers and NTP servers are now added to the /etc/hosts file.

New Features in Smart CID v1.1• HPE Smart CID supports Granular Scale out classification for HPE ConvergedSystem CS 500 v3.0.

• The following 2 new options have been added in this release:

• Clone a CID: You can now clone a CID to copy information from one CID to a new CID.

• Delete a CID: You can now delete a CID that is in Active status.

These options are available on the CID dashboard. Click Actions and Clone or Delete to clone or delete a CID.

• For HPE ConvergedSystem CS 500 v3.0, when configuring HANA DB for production systems, you can specify 2 additional instances of SAP HANA.

• In the Machine Information section, a new option to select Node size has been added.

• CID details can now be downloaded to your local computer as an HTML document. You can then print it or save it as a PDF file.

• For Scale Out systems that involve configuring multiple servers, configuration files generated by Smart CID are now available in a master zip file along.

New features in previous releases 25

Page 30: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• In the Customer Info section, 2 new fields, Role and Title, have been added.

New Features in Smart CID v1.0.2• HPE Smart CID supports HANA revision SPS09.

• HPE Smart CID supports ordering for HPE ConvergedSystems CS500 v3.0.

• A new section for Machine Information has been added for HPE ConvergedSystem CS500 v3.0. This section allows you to specify processor type, storage, sockets and disk encryption options for the system.

• Granular scale out configuration now supports configuring for 1 node to 16 nodes.

New Features in Smart CID v1.0.1• In the HANA DB section, HANA revision SPS09 has been added.

• In the Customer Info section, details to enter customer technical contact information has been added.

• In the Passwords section, usernames and passwords for Master and iLO have been added.

• In the Networking section, the tool now validates and allows a fully qualified domain name (FQDN) in the DNS and NTP server fields. These can also be the same value.

Fixes in Previous ReleasesThis section lists the fixes in the previous releases.

Fixes in Smart CID v4.0The following section lists the fixes in this release:

Fixes in CS500 and CS900 for SAP HANAThe following section lists the fixes in this release for CS500 and CS900 for SAP HANA:

• In HANA DB, validation has been added to ensure that users cannot enter any reserved values for SAP HANA SID.

Fixes in Smart CID v3.1The following section lists the fixes in this release:

• Smart CID now allows users with all CID access rights to view archived CIDs from all regions.

Fixes in CS700 for VirtualizationThe following section lists the fixes in this release for CS700 for Virtualization:

26 Fixes in Previous Releases

Page 31: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• Validation for saving data in the contact sections is added. A user cannot save data if email IDs are entered in an incorrect format in additional contacts in the Customer Info and HPE Contact Info sec-tions.

Fixes in CS500 and CS900 for SAP HANAThe following section lists the fixes in this release for CS500 and CS900 for SAP HANA:

• For CS500 v4.0, the MDC section has been removed from the Dashboard.

• For CS900 v4.0, in the HANA DB section, validation for System ID has been fixed. The System ID must consist of exactly three alphanumeric characters, only uppercase characters are allowed. The first character must be an alphabet, and the remaining characters can be alphabets or numeric.

• For CS900 v4.0, XML validation issue on a cloned CID due to nPartition Linux OS hostname is resolved. Smart CID verifies the Linux OS hostname on a cloned CID and displays an error message if it is entered in uppercase letters.

Fixes in Smart CID v3.0This section lists the fixes in this release.

Fixes in CS500 and CS900 for SAP HANA• For HPE CS900 v3.0, the HTML file does not display additional information in the HANA DB section.

• For HPE CS 500, in the HANA DB section, the option to select Standby server is only available in the Scale out configuration.

Fixes in CS700 for Virtualization• The 3PAR SKU array list for Single Rack, Single Rack with SAN switch and Multi Rack is modified in

the Storage section.

• Summary view, Excel, and XML output files for all VMs display Socket, Cores/Sockets and Storage size output values.

• The SNMP values are updated in the Summary view, Excel and XML files for Cisco 5K switch.

• Device power values are updated in the Summary view and the Excel file.

Fixes in Smart CID v2.3This section lists the fixes in this release.

Fixes in CS500 and CS900 for SAP HANA• For HPE ConvergedSystem 500 v4.0, in the HANA DB section, minimum and maximum memory val-

idation is added for checking the number of database instances depending on the available memory.

• For HPE Converged System 900 v4.0, in the HANA DB section, the correct Linux OS options are now updated.

Fixes in Previous Releases 27

Page 32: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• For HPE Converged System 900 v4.0, in the Network section, validation is added to check if IPv4 addresses are entered in the correct format.

• When you clone a CID that has no instances of HANA DB, the cloned CID does not display quorum server details in the network section.

• For HPE ConvergedSystem 500 v4.0, entering Virtual IP details in the User/BI Network section is optional. Entering one Virtual IP is mandatory for Data network.

• For HPE ConvergedSystem 500 v3.0, the Extra 3PAR section does not include the service processor and host name details for iLO/OA network.

• The limitation on the character length of host names in the Extra 3PAR section is now resolved. Ear-lier, the host names were limited to 13 characters. The limitation has been updated and host names can be more than 13 characters.

Fixes in CS700 for Virtualization• The Management Server related question in the Cloud System Related section is moved to the

Hardware Related Questions section.

Fixes in Smart CID v2.2.2This section lists the fixes in this release.

Fixes in CS 700 for Virtualization• The correct CloudSystem Management Gateway value is displayed in the Summary and the XL out-

put file.

• Cisco switch members, snet01 and soobm01, have lower member priority than HPE switches.

• DNS domain name addresses with four or more periods are now acceptable.

Fixes in CS500 and CS900 for SAP HANA• The labeling of uplink ports in the network form is corrected, 1 gbps is for Ethernet and 10gbps is for

fiber channel.

• Entering details in the iLO/OA network section is optional.

Fixes in Smart CID v2.2.1This section lists the fixes in this release.

Fixes in CS 700 for VirtualizationThe following section lists the fixes in this release for CS700 for Virtualization:

• Rack layout does not show HPE ProLiant WS460c Gen9 with PCI Expansion Blades (Graphics Server [No GPU]) option and HPE ProLiant WS460c Gen9 Blades (Graphics Server) option.

• For Hyper-V configuration, management server question is added to the hardware related questions section in Order Questionnaire.

28 Fixes in Previous Releases

Page 33: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• The Factory Input section now displays the number of management servers selected in Order Ques-tionnaire.

Fixes in CS500 and CS900 for SAP HANA• The Smart CID output file (deploysmartcid.sh) for HPE ConvergedSystem 500 v4.0 is updated

to set the correct hostnames for RHEL 7.

• The network configuration output file for HPE ConvergedSystem 500 is updated to set the default maximum transmission unit (MTU) value to 9000 for all VLANs.

• The correct XML dataset name for SR 4-Node configuration is displayed.

• The Smart CID version number is not displayed in the output files of all the configurations.

• It is now mandatory to provide Region details before submitting a CID.

• The hours of availability field is now optional.

• The CID dashboard now displays the 100% completion status only after the order number details are provided in the Customer contact section.

• For Dual Purpose HPE ConvergedSystem 900 v3.0, the HTML output file displays Dual Purpose configuration information.

• For HPE ConvergedSystem 500 v4.0, the ifcfg file is now updated to match solution requirements as per the Visio diagram.

• The XML output file for HPE ConvergedSystem 900 v4.0 is updated as per new XML Schema Defini-tion (XSD) values.

The HTML output file now displays the following HANA DB information:

• SAP HANA pre-installation.

• Secondary instance for the second database instance.

• Secondary instance and Instance name for the third database instance.

Fixes in Smart CID v2.2This section lists the fixes in this release.

Fixes in CS 700 for VirtualizationThe following section lists the fixes in this release for CS700 for Virtualization:

• Solution component in network switch IRF domain ID (2nd pair) values are displayed in the Sum-mary View and Excel Output.

• v Cloud suit related question has been removed from the Order Questionnaire.

• Network switches IRF/PPC domain ID's value has been corrected to display the user defined values in Summary view.

• 7000 power label has been removed from 3PAR store serve Rack power label in Storage Rack power requirement table.

• Default selection has been implemented for few questions in Order Questionnaire.

• Submitted CIDs show the correct status instead of a hyphen (-).

Fixes in Previous Releases 29

Page 34: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• Submit check has been implemented if the user changes the VM ware version from 6.0 to 5.5 and doesn’t update the Rack Layout.

• VSR settings now displays the user defined hostname for RMC.

Fixes in CS500 and CS900 for SAP HANAThe following section lists the fixes in this release for CS500 and CS900 for SAP HANA:

• For CS500, the HTML view displays correct Operating mode and Factory preinstall selection for Dual Purpose instances.

• For CS500, the HTML view displays correct Primary network information.

• For CS500, the formula for calculating memory is updated as per the new SAP HANA rules.

Fixes in Smart CID v2.1This section lists the fixes in this release.

Fixes in CS500 and CS900 for SAP HANAThe following section lists the fixes in this release for CS500 and CS900 for SAP HANA:

• For CS900, the Passwords section has been updated with new passwords for OA, iLO, SAN and both switches (5900 and 6125X switches).

• For CS900, Summary has been updated with the correct HANA information.

• In the output XML files, bonding parameters have been updated.

• The issue of allowing using underscores ( _ ) and periods ( . ) in hostnames has been restricted. Smart CID does not allow underscores and periods in hostname fields. Only alphabets (A-Z/a-z) and hyphens ( - ) are allowed in hostnames.

Fixes in Smart CID v2.0The following section lists fixes in this release:

• Browser compatibility issues with Internet Explorer has been fixed for HPE ConvergedSystem CS900 v3.0.

• Search has been removed from the CID dashboard. It is only available on the Profile CIDs page.

• Error messages, that are displayed when submitting a CID, have been updated to display the correct and exact missing information in each section.

Fixes in CS500 and CS900 for SAP HANAThe following section lists the fixes in this release for CS500 and CS900 for SAP HANA:

• In HANA DB, the minimum and maximum values that are displayed in the memory utilization fields have been removed. These values have been added as a table in HANA DB.

• The issue of underscore ( _ ) in iLO hostnames has been fixed. Smart CID does not allow usage of underscore in the iLO hostname.

30 Fixes in Previous Releases

Page 35: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• For HPE ConvergedSystem CS500 v3.0 max scale out configuration, the default number of racks in Rack Layout is set to 4.

• Validation for the number of racks and servers has been fixed for HPE ConvergedSystem CS500 v2.0 granular scale out configuration.

• Validation for the gateway IP address has been fixed. Smart CID now validates the gateway IP address against the subnet IP address to ensure that the gateway IP address belong to the same subnet.

• Validation for OS versions for HANA DB has been fixed. Smart CID now checks OS versions of pri-mary instance of HANA DB and Dual-Purpose HANA DB and displays an error if they are different.

• In Passwords, the 3PAR console SSMC field is now updated for all older CIDs.

• In Network section, customer IP count is calculated and auto-populated based on the number of devices in that network.

• NFS and HANA Internal network sections have been removed from Network.

Fixes in Smart CID v1.2.1• Smart CID now displays the complete name of the system and its configuration on the dashboard.

• For HPE ConvergedSystem CS 900 v3.0, the device name for Management External Network is changed to RC01-LAN-SWITCH-BOT.

• For RHEL CIDs, the auto generated network file now contains only the hostname. Earlier, the net-work file listed the Fully Qualified Domain Name (FQDN).

• In the Network section, when the first IP address for device configuration for each network is changed or updated, Smart CID now updates the Subnet IP address automatically.

• For Dual Purpose systems, location for Data Replication can now be set for primary or secondary site.

• 1.5 TB memory size placeholder issue in HANA DB is fixed.

• For HPE ConvergedSystem CS500 v3.0, in Machine Information section, you can now select 4 sock-ets and node size of 2 TB. Selecting this option automatically checks and validates memory size in HANA DB.

Fixes in Smart CID v1.2• Smart CID now allows users to enter hostnames and IP addresses for devices in Shared networks.

• Entering HANA DB information is now sequential. Options to enter SAP system name and other details for the second and third instances are available only after details of the primary instance of HANA are entered.

• Memory utilization is now checked and validated only after values are entered for all instances of HANA.

• Time zone issue in Network section is fixed. Earlier, in some cases, selecting a time zone did not allow saving Network information.

• In HANA DB, validation for all fields has been removed when the operation mode is None.

• The limitation on the character length of hostnames is now resolved. Earlier, hostnames were limited to 13 characters. This limitation has been updated and hostnames can now be more than 13 charac-ters.

Fixes in Previous Releases 31

Page 36: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• DP is now changed to Dual Purpose. DP has now changed to Dual Purpose and the primary instance of a Dual Purpose system is the HANA DP instance.

• Color coding for networks is now updated to match the Microsoft Visio setup diagram.

• The default username for 59XX network switch is changed to admin.

• The default password for 3PAR console SSMC is updated to HP1nv*nt.• Smart CID report is now enhanced for better readability.

Fixes in Smart CID v1.1.2• Smart CID now validates the value of instance memory in HANA DB against the 1.5 TB node size

option in Machine Information.

• Time zones in HANA DB and Common Network Information for cloned CIDs are automatically cop-ied from the original CIDs. Earlier, you had to manually update the time zones in both sections after cloning a CID.

• Option to disable disk encryption in Machine Information has been added.

• Host names in Storage network and Internal network sections are now editable. Earlier, the default usernames were locked for editing.

• Physical Connections section in each network is now updated to the following options:

• 1000BaseT Ethernet RJ45

• 40/10Gbps QSFP+/SFP+ with optional 10Gbps SR Fiber SC

• The issue of domain names appended to the DNS and NTP servers in the etc/hosts file is now fixed.

• Localhost entries for IPV4 and IPV6 are now added in the /etc/hosts output file.

Fixes in Smart CID v1.1.1• When creating a new CID, Smart CID does not open the Customer Info window by default. It is no

longer mandatory to enter this information when creating a new CID. You can enter or update this information before submitting the CID.

• Default value for Region in the Customer Contact section is now set to Select a Region.

• In HANA DB, for Dual purpose scale out systems, option to select RHEL has been removed.

• Hostnames are now assigned based on the primary network. If you select Management network as the primary network, the hostname specified here is populated in the configuration files.

• You can now view CIDs based on regions. Log in using the region specific login ID to view CIDs that are specific only to that region. The following table lists the login IDs to use to view region-wise CIDs. Send an email to [email protected] for passwords.

Table 1. Viewing CIDs by region

Login ID Password

[email protected] AMERICAS

[email protected] EMEA

[email protected] APJ

32 Fixes in Previous Releases

Page 37: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

Fixes in Smart CID v1.1• Validation of duplicate hostnames across different sections has been fixed. Smart CID now checks

for hostnames across sections (for example, HANA DB, Network and 3PAR Info sections) and alerts users if hostnames are identical.

• Validation of duplicate SAP system name in HANA DB and DP (Dual Purpose) HANA DB sections has been fixed. Smart CID now checks for SAP system name in HANA DB and DP HANA DB sections, and alerts users if SAP system names are identical.

• CID summary now displays Region in the Customer Information section.

• In the Rack Layout section, validation has been added to ensure that users cannot enter 0 (zero) in the fields for number of racks and number of servers.

• Extra 3PAR section is not applicable for non-DP systems. When creating a CID for non-DP systems, the Extra 3PAR section is not displayed.

• Standby server is not applicable for scale up configuration. This option is not displayed in the HANA DB section when creating a CID for scale up systems.

• Validation for SAP system number in HANA DB has been added for Dual purpose systems. When you enter the SAP system number (for example, 22) in the primary HANA instance, Smart CID does not allow you to enter the next number (23) as SAP system number in DP HANA DB.

Fixes in Smart CID v1.0.2• In Networking, sharing rules have been implemented to ensure that networks are shared logically.

• In Networking, value of subnet is now auto populated based on the system IP address and netmask. IP addresses of a network are now checked to ensure that they belong to same network subnet.

• In HANA DB, for non-production systems, the tool validates for instances memory to ensure that the sum of all instances does not exceed 90% of the total memory.

• In Networking, the tool now allows CIDR suffixes from /1 to /32 for DNS and NTP servers. Earlier, only /8, /16, /24 and /32 were allowed.

• In IRS, hostnames and proxy server names can have names that are lesser than 6 characters (root, for example).

• Extra 3PAR is not applicable for scale up systems. When configuring for scale up systems, this sec-tion is not displayed on the dashboard.

• Validation for iLO has been added. A user cannot submit a CID without entering iLO details.

• Validation for iLO hostname has been updated. Smart CID now supports up to 25 characters includ-ing “-” (hyphen) for the iLO hostname.

• Network validations have been updated. Smart CID does not validate or check for private IPs.

• When entering information for Dual Purpose systems, entering DR information is mandatory. The default value for DR has been changed from No to Yes. The No option in DR is disabled for Dual Purpose systems.

• Scale up systems can now be configured for non-production environments. In the HANA DB section, an option to configure a system for a non-production environment has been added.

Fixes in Smart CID v1.0.1• Profile CIDs are now displayed by names of systems and their configuration.

Fixes in Previous Releases 33

Page 38: Smart CID Release Notes · PDF fileSmart CID Release Notes Version 4.2 Abstract This document is intended for Pre- Sales, Account Managers, ... HPE ConvergedSystem 500 for SAP HANA

• Phone number fields in all contact forms are now updated to the international format:

• + [Country Code] [Area Code] [Phone Number]

• Validation of duplicate IP addresses has been fixed. The tool checks for duplicate IP addresses across forms to ensure that there are no duplicate IP addresses. However, the tool allows entering the same IP address for DNS server and NTP server. Verify all the IP addresses manually and ensure that IP addresses are unique across forms.

• Gateway IP is now checked to validate if it belongs to local subnet. Subnet is now auto calculated based on provided netmask.

• In HANA DB, in testing, development or other environments, you can now specify pre-installation revisions for the optional instances. This was not available in the earlier version.

• The issue of the HANA DB form loading data consistently has been resolved. The form now loads the correct information.

• The labels for Passwords and Rack Layout sections have been changed from Edit to Confirm.

• When creating a new CID, you can now have the same HPE order number or SAP order number for 2 or more CIDs. Earlier, duplicate order numbers were not allowed.

• 3PAR Remote Access and Insight Remote Support sections are independent of each other. Earlier, entering information in the 3PAR Remote Support required IRS to be enabled. This has been fixed. You can now enter 3PAR Remote Access even if IRS is not enabled.

• In HANA DB, the SAP User IDs and the SAP Group IDs now support values up to 2^64.

• In HANA DB, SAP User IDs and Group IDs are not compared against each other. They can have the same value. User IDs are compared with other User IDs only and Group IDs are compared with other Group IDs only. Earlier User ID and Group ID were compared and could not have the same value.

• In DP systems, optional instances cannot be configured for primary sites.

• The tool now validates Web proxy server port names to ensure that decimal numbers cannot be entered.

34 Fixes in Previous Releases