4
Fire Alarm Systems | SM 210 LSN RW Single Action Call Points The SM 210 LSN RW Single Action Call Point is used for setting off an alarm by hand in the LSN. They are suitable for use throughout Europe (except Germany). System Overview j 4 j 4 j 4 2 1 B A Pos. Description 1 Call points for interior areas (IP 54) 2 Call points for exterior areas (IP 67) with sealed surface-mount- ed housing A For installation on a flush-mounted box, with cover frame B Surface-mounted housing SM 210 LSN RW Single Action Call Points Alarm triggering by breaking of the glass pane Protection against injury with foil-labeled pane Indicator LED for triggered alarm or for inspection evaluation Individual call point identification Call point query routines with evaluation and multiple transmission. www.boschsecurity.com

SM 210 LSN RW Single Action Call Pointsresource.boschsecurity.com/documents/Data_sheet... · 2 1 A B Pos. Description 1 Call points for interior areas (IP 54) 2 Call points for exterior

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SM 210 LSN RW Single Action Call Pointsresource.boschsecurity.com/documents/Data_sheet... · 2 1 A B Pos. Description 1 Call points for interior areas (IP 54) 2 Call points for exterior

Fire Alarm Systems | SM 210 LSN RW Single Action Call Points

The SM 210 LSN RW Single Action Call Point is used forsetting off an alarm by hand in the LSN.

They are suitable for use throughout Europe (exceptGermany).

System Overview

j 4

j 4j 4

2

1

BA

Pos. Description

1 Call points for interior areas (IP 54)

2 Call points for exterior areas (IP 67) with sealed surface-mount-ed housing

A For installation on a flush-mounted box, with cover frame

B Surface-mounted housing

SM 210 LSN RW Single Action Call Points▶ Alarm triggering by breaking of the glass pane

▶ Protection against injury with foil-labeled pane

▶ Indicator LED for triggered alarm or for inspectionevaluation

▶ Individual call point identification

▶ Call point query routines with evaluation and multipletransmission.

www.boschsecurity.com

Page 2: SM 210 LSN RW Single Action Call Pointsresource.boschsecurity.com/documents/Data_sheet... · 2 1 A B Pos. Description 1 Call points for interior areas (IP 54) 2 Call points for exterior

2 | SM 210 LSN RW Single Action Call Points

Functions

2

4

35

1

After the glass pane (1) is broken, the alarm is triggered bythe call point of the microswitch (2) jumping forward andthe indicator LED (3) blinks.

To reset the microswitch (2), replace the glass plate (1).The indicator LED (3) goes out.

This does not reset the alarm on the fire panel.

Individual call point identification with display of the callpoint address on the fire panel ensures the quick locationof the triggered call point.

Call point test (test alarm):In an alarm test, the button key is pushed upwards into thecut-out (4). This releases the catch (5) on the plate (1): theplate shifts downwards and the microswitch is triggered(2).

VariantsThe designs of the Single Action Call Points for interior andexterior areas are identical. Three installation variants areavailable:

• SM 210 LSN RW, for indoor surface mounting• SM 210 LSN RW, for indoor flush mounting• SM 210 LSN RW, for outdoor surface mountingThe call points for interior areas are available in red andblue; the call points for exterior areas are available in red.

Installation/Configuration Notes

• Manual call points must be mounted visibly alongescape and rescue routes (e. g. exits, passageways,stairwells) and be easily accessible.

• An installation height of 1400 mm ±200 mm, measuredfrom the middle of the call point to the floor, must bemaintained.

• Manual call points must be adequately illuminated bysunlight or another light source (including emergencylighting if present).

• The maximum number of LSN elements that may beconnected depends on their current consumption fromthe LSN data line. The limit values should be taken fromthe product information supplied with the fire panelused.

• Standards, guidelines and planning recommendationsregarding the installation location etc. should also betaken into consideration.

• The regulations of the local fire services must beobserved.

Parts Included

Type of device Qty. Components

SM 210 LSN RW,red, for surfacemounting in indoorareas

111

Single Action Call Point, red housingSurface-mounted housing, color redKey

SM 210 LSN RW,red, for surfacemounting in indoorareas

111

Single Action Call Point, red housingCover frame, redKey

SM 210 LSN RW,blue, for surfacemounting in indoorareas

111

Single Action Call Point, blue housingSurface-mounted housing, color blueKey

SM 210 LSN RW,blue, for surfacemounting in indoorareas

111

Single Action Call Point, blue housingCover frame, blueKey

SM 210 LSN RW,red, for surfacemounting in outdoorareas

111

Single Action Call Point, red housingSurface-mounted housing, IP 67, color redKey

Technical Specifications

Electrical

Operating voltage 10 V DC . . . 33 V DC

Current consumption 0.4 mA

Mechanics

Dimensions (H x W x D)

• Indoor area surface mounting 87 x 87 x 53 mm

• Indoor area flush mounting 107 x 107 x 20 (36) mm

• Outdoor area surface mount-ing

111 x 111 x 65 mm

Housing material Plastic, ABS

Page 3: SM 210 LSN RW Single Action Call Pointsresource.boschsecurity.com/documents/Data_sheet... · 2 1 A B Pos. Description 1 Call points for interior areas (IP 54) 2 Call points for exterior

SM 210 LSN RW Single Action Call Points | 3

Colors • Red, RAL 3001• Blue, RAL 5005

Weight Approx. 400 g

Environmental Considerations

Protection class as per EN 60529

• Detector for indoor areas IP 54

• Detector for outdoor areas IP 67

Permissible operating temperature -25 °C . . . +65 °C

Ordering Information

SM 210 LSN RW, Red, for Surface Mountingin Indoor Areaswith surface-mounted housing

SM210-S-red

SM 210 LSN RW, Red, for Flush Mounting inIndoor Areaswith masking frame for larger wall cuts

SM210-R-red

SM 210 LSN RW, Blue, for Surface Mountingin Indoor Areaswith surface-mounted housing

SM210-S-blue

SM 210 LSN RW, Blue, for Flush Mountingin Indoor Areaswith masking frame for larger wall cuts

SM210-R-blue

SM 210 LSN RW, Red, for Surface Mountingin Outdoor Areaswith surface-mounted housing

SM210-S-red-outd

Accessories

Spare Glass Panesfor Single Action Call Points SM 210 LSN RW/SM 120 RW, PU = 10 units

SM210-SPARE-GLASS

www.boschsecurity.com

Page 4: SM 210 LSN RW Single Action Call Pointsresource.boschsecurity.com/documents/Data_sheet... · 2 1 A B Pos. Description 1 Call points for interior areas (IP 54) 2 Call points for exterior

4 | SM 210 LSN RW Single Action Call Points

Americas:Bosch Security Systems, Inc.130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 [email protected]

Europe, Middle East, Africa:Bosch Security Systems B.V.P.O. Box 800025600 JB Eindhoven, The NetherlandsPhone: + 31 40 2577 284Fax: +31 40 2577 [email protected]

Asia-Pacific:Robert Bosch (SEA) Pte Ltd, Security Systems38C Jalan PemimpinSingapore 577180Phone: +65 6319 3453Fax: +65 6319 [email protected]

Represented by

© Bosch Security Systems Inc. 2009 | Data subject to change without noticeT285376651 | Cur: en-US, V10, 12 Feb 2009