Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
1215 1216
Mold Accessories
SLOTTED KEYS SHOT COUNTERS FOR MOLD
Type R
KED KES KEG S45C
KEDS KESS KEGS SUS316
Bh9
Bh9
Bh9
H
L L L
1.6
1.6 25 25
6.3
C
6.3
H
6.3
6.3
H
6.3
6.3
B/2 B/2
KEDKEDS (Stainless steel)
KESKESS (Stainless steel)
KEGKEGS (Stainless steel)
JIS B1301-1996V Tensile strength: 600N/mm2 or more
Part Number L
H
ToleranceC
Type Bh9
KEDKEDS (Stainless steel)
KESKESS (Stainless steel)
KEGKEGS (Stainless steel)
2 0-0.025
10 15 20 2 0-0.025 0.16~0.253 10 15 20 25 30 3
40-0.030
10 12 15 16 18 20 25 30 35 40 45 50 40-0.0305 10 12 15 16 18 20 25 30 35 40 45 50 5
0.25~0.406 10 12 15 16 18 20 25 30 35 40 45 50 55 60 6
70-0.036
15 20 25 30 35 40 45 50 55 60 7
0-0.036
8 15 16 18 20 25 30 35 40 45 50 55 60 70 80
0-0.090
10 15 18 20 25 30 35 40 45 50 55 60 70 80 8
0.40~0.60
12
0-0.043
20 25 30 35 40 45 50 55 60 70 80
14 30 35 40 45 50 55 60 70 80 90 9
15 30 35 40 45 50 55 60 70 80 9010
16 40 45 50 55 60 70 80 90 100
18 40 45 50 55 60 70 80 90 100 110 11 0-0.110
L Tolerance
10 0-0.15
12 15 16 18 0-0.18
20 25 30 0-0.21
35 40 45 50 0-0.25
55 60 70 80 0-0.30
90 100 110 0-0.35
Part Number - L
KED6 - 30
Part Number - LM-CVPLM-CVEXM-CVR - 64.2
Part Number - L(C)
KED6 - LC28
Alteration Code Spec. 1Code
Full length
alteration
LC
LC
L dimension can be designated in 1mm increments.
B LC range B LC range2 5~20 10 15~ 803 6~30 12 20~ 804 8~50 14 25~ 905 8~50 15 25~ 906 10~60 16 35~1007 15~60 18 35~1108 15~80
①Shot Counter
②Actuation Block
ID Plates for tool identification
V Manufactured by PROGRESSIVE Corporation. Counter View is a trademark of PROGRESSIVE Corporation. PAT. PEND.
9 9 9 9 9 8 0NP65080
L±0.1
5
6
PROGRESSIVE
Actuator Rod
Counter Pin
No.8-32UNCInch screw
Serial number
NP65080
26 12.7
20 6.35
47.5
24
4.5
38 28 38 28
26
18
PROGRESSIVE
1 Shot Counter
Serial number
Counter Pin 2 Actuation BlockM-CVPL (Parting line mount type) only ①M-CVEX (External mount type) ①+②
M-CVR (Round type)
V ID Plate design is subject to change without prior notice.
① R Glass-filled nylon housingP Socket Head Cap Screws M4-25 (2 pieces)
ID Plates for tool identificationMaximum operating temperature 120℃
R Glass-filled nylon housingMaximum operating temperature 120℃
R S45CP Actuator RodS Electroless nickel plated
① R SteelP Socket Head Cap Screws M4-25 (2 pieces)
M-CVR1. Bore the holes for the counter and actuator rod to the dimensions shown in the figure
below, from the rear of the movable mold plate.2. Slot an opening for the display panel of the counter to the dimensions shown in the
figure below.3. Ensure that the actuator rod protrudes 4.0mm above the parting line and decide L
dimension depending on the mold plate thickness.4. Screw the actuator rod into the plunger and insert the counter from the rear of the mold plate.5.Retain the bottom of the counter with the support plate.
■Mounting dimensions and methodM-CVPL (Parting line mount type) M-CVEX (External mount type)
NP65080
38+
0.3
+0.
1
28
R8
PROGRESSIVE
*48 26+0.2
0
24
Movable mold plate
(Movable mold plate side chart)
P.L. Mold Closed
ActuationBlock
Fixed mold plate
Movable mold plateShot Counter
φ22
.25+
0.12
0
4±0.25 12.5±0.12
φ7
0 0 0 0 0 0 0NP65080 19.
050
-0.0
2
max.R0.75
PROGRESSIVE
46.75
T
+0.120
41.25+0.25
0
max.R0.75
Movable mold plateSupport plate (Movable mold plate side chart)
Actuator Rod
Plate thickness
V Installation dimension shown in above figure is just for reference purpose.V Stroke distance of the counter pin for counting function is set at 3.75mm or more.
If the stroke is less than 3.75mm, the counter will not work.Conversely, when the stroke exceeds 4.25mm, the counter may be damaged.
Part Number U/Price1~9
M-CVPL(only ①)
Part Number U/Price1~9
M-CVEX(①+②)
Part Number
L0.1mm increments
U/Price1~9
M-CVR 60.0~124.0
■Method of specifying the L dimension
L=Movable mold plate thickness T+actuator rod protrusion of 4.0mmV Specify taking into account the tolerance of the mold plate thickness T.V The protruding part of the actuator rod is the stroke of the actuator
rod. If the stroke is less than 3.75mm, the counter will not work. Conversely, if the stroke exceeds 4.25mm, the counter may be damaged when the mold closes.
■Features・Counting is actuated mechanically, no miscount will occur if counter is installed correctly.・ Each counter has a different serial number that will be used to identify the counter with the mold. V Counters are sold in random order.・ ID Plate for tool identification is included for M-CVPL and M-CVEX only. Apply the adhesive seal at the back of the ID Plate to the front of the counter.
■NotesV The Counter is non-resettable mechanical.V For mold testing purposes, the 7-digit indicator does not start from 0(a value of 9999980 will be shown).V M-CVR Counter: Ensure that the actuator rod has a stroke of 4.0mm±0.25.
M-CVPL, M-CVEX:CounterView™ Shot Counter is a registered trademark of Progressive Components International Corporation, covered by US Patent No.5,571,539, Canadian Patent No. 2,166,237, European Patent No. EP726129 and Others pending.
M-CVR:CounterView™ Shot Counter is a registered trademark of Progressive Components International Corporation, covered by US Patent No.5,571,539, Canadian Patent No. 2,166,237, European Patent No. EP726129, S.African Patent No. 2005/5337 and Asia and others pending.
QuotationQuotation
QuotationQuotation
QuotationQuotation
QuotationQuotationQuotationQuotationQuotationQuotation
Quo
tati
on
Quo
tati
on
V Non JIS material definition is listed on P.1351 - 1352
QuotationQuotation
QuotationQuotation