Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
SHEET INDEX PROJECT INFORMATION
APPROVALSAPPROVED BY: INITIALS: DATE:
VENDOR:
LEASING / LANDLORD:
R.F.:
ZONING:
CONSTRUCTION:
POWER / TELCO:
PG&E:
CODE COMPLIANCE
PROJECT DESCRIPTION PROJECT TEAM
GENERAL CONTRACTOR NOTES
DO NOT SCALE DRAWINGSTHESE DRAWINGS ARE FORMATTED TO BE FULL SIZE AT 24" x 36". CONTRACTORSHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ONTHE JOBSITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER INWRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK ORMATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME.
DIRECTIONS FROM AT&T
PROPERTY INFORMATION:SITE NAME: POINT REYES LIFEBOAT STN
SITE NUMBER: CCL02454
SITE ADDRESS: SIR FRANCES DRAKE BLVD.INVERNESS, CA. 94937
A.P.N. NUMBER: 109-270-08
CURRENT ZONING: C-ARP-60 (COASTAL AGRICULTURAL/RESIDENTIAL/PLANNED DEVELOPMENT 60 ACRES)
JURISDICTION: COUNTY OF MARIN
LATITUDE: N 37°59'44.62" (NAD83)
LONGITUDE: W 123°00'12.84" (NAD83)
ELEVATION: 551.5' A.M.S.L.
DIRECTIONS FROM AT&T's OFFICE AT 2600 CAMINO RAMON, SAN RAMON, CA
OCCUPANCY AND CONSTRUCTION TYPE
1. HEAD NORTHEAST TOWARD SUNSET DR.2. TURN RIGHT.3. TURN RIGHT TOWARD SUNSET DR.4. TURN LEFT TOWARD SUNSET DR.5. CONTINUE ONTO SUNSET DR.6. TURN SLIGHTLY RIGHT TOWARD BOLLINGER CANYON RD.7. TURN RIGHT ONTO BOLLINGER CANYON RD.8. MERGE ONTO I-680 N VIA THE RAMP TO SACRAMENTO.9. TAKE EXIT 46A FOR STATE ROUTE 24 TOWARD OAKLAND/LAFAYETTE.10. CONTINUE ONTO CA-24 W.11. TAKE EXIT 2B FOR INTERSTATE 580 W.12. MERGE ONTO I-580 W.13. MERGE ONTO I-580 W/I-80 E TOWARD BERKELEY/SACRAMENTO.14. KEEP LEFT TO STAY ON I-580 W/I-80 E.15. TAKE EXIT 13B FOR I-580 TOWARD SAN RAFAEL/POINT RICHMOND.16. CONTINUE ONTO I-580 W.17. MERGE ONTO US-101 N.18. TAKE EXIT 456 FOR LUCAS VALLEY RD.19. TURN LEFT ONTO LUCAS VALLEY RD.20. TURN RIGHT ONTO NICASIO VALLEY RD.21. SLIGHT LEFT TO STAY ON NICASIO VALLEY RD.22. TURN LEFT ONTO PT. REYES - PETALUMA RD.23. TURN RIGHT TO STAY ON PT. REYES - PETALUMA RD.24. TURN LEFT ONTO CA-1 S.25. TURN RIGHT ONTO SIR FRANCIS DRAKE BLVD.26. TURN LEFT TO STAY ON SIR FRANCIS DRAKE BLVD.27. DESTINATION WILL BE ON THE LEFT.
AT&T:
VICINITY MAP
REVPROPERTY OWNER:PACIFIC TELEPHONE AND TELEGRAPH
1. T-1 TITLE SHEET #2. GN-1 GENERAL NOTES, ABBREVIATIONS, & NOTES #3. C-1 PLOT PLAN AND SITE TOPOGRAPHY #4. A-1.1 OVERALL SITE PLAN #5. A-1.2 ENLARGED SITE PLAN #6. A-2.1 EXISTING / DEMOLITION PLAN #7. A-2.2 EQUIPMENT LAYOUT PLAN #8. A-3.1 ANTENNA LAYOUT PLANS #9. A-3.2 ANTENNA DETAILS #10. A-3.3 RRH DETAILS #11. A-4.1 PROPOSED ELEVATION #12. A-4.2 PROPOSED ELEVATION #13. A-4.3 PROPOSED ELEVATION #14. A-4.4 PROPOSED ELEVATION #
NEW SITE BUILD UNMANNED TELECOMMUNICATIONS FACILITY.
1. BRING POWER / TELCO / FIBER TO SITE LOCATION
2. INSTALL AT&T APPROVED INDOOR EQUIPMENT RACKSAND ASSOCIATED INTERIOR EQUIPMENT
3. PROPOSED AT&T MONOPOLE WITH ANTENNAS & ASSOCIATEDTOWER-MOUNTED EQUIPMENT.
4. INSTALL AT&T GENERATOR W/ FUEL TANK
APPLICANT / LESSEE:AT&T2600 CAMINO RAMON, 4W850 NSAN RAMON, CA 94583
ARCHITECT / ENGINEER:MST ARCHITECTS INC.1520 RIVER PARK DRIVESACRAMENTO, CA 95815CONTACT: MANUEL S. TSIHLASEMAIL: [email protected]: (916) 567-9630
FA CODE: 12882118
USID: 263689
PROJECT SITE
SIR F
RANC
IS D
RAKE
BLV
D.
CHIMNEY ROCK RD.
RF ENGINEER:AT&T5001 EXECUTIVE PKWY,SAN RAMON, CA 94583CONTACT: STEPHEN NELSONEMAIL: [email protected]: (925) 395-3690
SITE ACQUISITION:COMPLETE WIRELESS CONSULTING, INC.2009 V STREETSACRAMENTO, CA 95818CONTACT: KASSIE YDEEMAIL: [email protected]: (916) 217-2309
HANDICAP REQUIREMENTS
SITE TYPE: INDOOR EQUIPMENT RACKS /
MONOPOLE
OCCUPANCY : U (UNMANNED TELECOMMUNICATIONS FACILITY)
CONSTRUCTION TYPE: V-B
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITHTHE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNINGAUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOTCONFORMING TO THESE CODES.
1) 2019 CALIFORNIA ADMINISTRATIVE CODE
2) 2019 CALIFORNIA BUILDING CODE
3) 2019 CALIFORNIA ELECTRICAL CODE
4) 2019 CALIFORNIA MECHANICAL CODE
5) 2019 CALIFORNIA PLUMBING CODE
6) 2019 CALIFORNIA ENERGY CODE
9) 2019 CALIFORNIA FIRE CODE
11) 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE
12) 2019 CALIFORNIA REFERENCE STANDARDS CODE
FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, ACCESSIBILITYACCESS AND REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE2019 CBC 11B-203.5, AND 11B-202.4 EXCEPTION 7.
SITE ACQUISITION:COMPLETE WIRELESS CONSULTING, INC.2009 V STREETSACRAMENTO, CA 95818CONTACT: KASSIE YDEEMAIL: [email protected]: (916) 217-2309CONSTRUCTION MANGER:
BECHTEL5000 EXECUTIVE PARKWAY,BISHOP RANCH 8, STE 350SAN RAMON, CA 94583CONTACT: SEAN WATSONEMAIL: [email protected]: (925) 594-9070
SITE NUMBER: CCL02454
SITE NAME: POINT REYES LIFEBOAT STN
SIR FRANCES DRAKE BLVD.
INVERNESS, CA. 94937
JURISDICTION: COUNTY OF MARIN
APN: 109-270-08
TITLE SHEET
T-1
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
PLANS ARE INTENDED TO BE DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS,EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.
1.
THE CONTRACTOR SHALL OBTAIN, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINEDOR IDENTIFIED BY THE CONTRACT DOCUMENTS.
2.
CONTRACTOR SHALL CONTACT USA (UNDERGROUND SERVICE ALERT) AT (800) 227-2600, FOR UTILITY LOCATIONS, 48 HOURS BEFOREPROCEEDING WITH ANY EXCAVATION, SITE WORK OR CONSTRUCTION.
3.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESSSPECIFICALLY INDICATED OTHERWISE, OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE.
4.
ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CBC / UBC'S REQUIREMENTS REGARDING EARTHQUAKE RESISTANCE, FOR, BUTNOT LIMITED TO, PIPING, LIGHT FIXTURES, CEILING GRID, INTERIOR PARTITIONS, AND MECHANICAL EQUIPMENT. ALL WORK MUST COMPLYWITH LOCAL EARTHQUAKE CODES AND REGULATIONS.
5.
REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY DRAWINGS, SHALL NOT BE USED TO IDENTIFY ORESTABLISH BEARING OF TRUE NORTH AT THE SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANYSURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL NOTIFY THE ARCHITECT / ENGINEER PRIOR TOPROCEEDING WITH THE WORK IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THETRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO NOTIFYTHE ARCHITECT / ENGINEER.
6.
THE BUILDING DEPARTMENT ISSUING THE PERMITS SHALL BE NOTIFIED AT LEAST TWO WORKING DAYS PRIOR TO THE COMMENCEMENT OFWORK, OR AS OTHERWISE STIPULATED BY THE CODE ENFORCEMENT OFFICIAL HAVING JURISDICTION.
7.
DO NOT EXCAVATE OR DISTURB BEYOND THE PROPERTY LINES OR LEASE LINES, UNLESS OTHERWISE NOTED.8.
ALL EXISTING UTILITIES, FACILITIES, CONDITIONS, AND THEIR DIMENSIONS SHOWN ON THE PLAN HAVE BEEN PLOTTED FROM AVAILABLERECORDS. THE ARCHITECT / ENGINEER AND THE OWNER ASSUME NO RESPONSIBILITY WHATSOEVER AS TO THE SUFFICIENCY OR THEACCURACY OF THE INFORMATION SHOWN ON THE PLANS, OR THE MANNER OF THEIR REMOVAL OR ADJUSTMENT. CONTRACTORS SHALL BERESPONSIBLE FOR DETERMINING EXACT LOCATION OF ALL EXISTING UTILITIES AND FACILITIES PRIOR TO START OF CONSTRUCTION.CONTRACTORS SHALL ALSO OBTAIN FROM EACH UTILITY COMPANY DETAILED INFORMATION RELATIVE TO WORKING SCHEDULES ANDMETHODS OF REMOVING OR ADJUSTING EXISTING UTILITIES.
9.
CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES, BOTH HORIZONTAL AND VERTICALLY, PRIOR TO THE START OF CONSTRUCTION. ANYDISCREPANCIES OR DOUBTS AS TO THE INTERPRETATION OF PLANS SHOULD BE IMMEDIATELY REPORTED TO THE ARCHITECT / ENGINEER FORRESOLUTION AND INSTRUCTION, AND NO FURTHER WORK SHALL BE PERFORMED UNTIL THE DISCREPANCY IS CHECKED AND CORRECTED BYTHE ARCHITECT / ENGINEER. FAILURE TO SECURE SUCH INSTRUCTION MEANS CONTRACTOR WILL HAVE WORKED AT HIS/HER OWN RISK ANDEXPENSE.
10.
ALL NEW AND EXISTING UTILITY STRUCTURES ON SITE AND IN AREAS TO BE DISTURBED BY CONSTRUCTION SHALL BE ADJUSTED TO FINISHELEVATIONS PRIOR TO FINAL INSPECTION OF WORK.
11.
ANY DRAIN AND/OR FIELD TILE ENCOUNTERED / DISTURBED DURING CONSTRUCTION SHALL BE RETURNED TO IT'S ORIGINAL CONDITIONPRIOR TO COMPLETION OF WORK. SIZE, LOCATION AND TYPE OF ANY UNDERGROUND UTILITIES OR IMPROVEMENTS SHALL BE ACCURATELYNOTED AND PLACED ON "AS-BUILT" DRAWINGS BY GENERAL CONTRACTOR, AND ISSUED TO THE ARCHITECT / ENGINEER AT COMPLETIONOF PROJECT.
12.
ALL TEMPORARY EXCAVATIONS FOR THE INSTALLATION OF FOUNDATIONS, UTILITIES, ETC., SHALL BE PROPERLY LAID BACK OR BRACED INACCORDANCE WITH CORRECT OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REQUIREMENTS.
13.
INCLUDE MISC. ITEMS PER AT&T SPECIFICATIONS14.
SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCALAUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION.
THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN.
SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS:
- AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE- AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, NINTH EDITION- TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA) 222-G, STRUCTURAL STANDARD FOR STRUCTURAL ANTENNA TOWER AND ANTENNASUPPORTING STRUCTURES- INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH RESISTIVITY, GROUND IMPEDANCE, ANDEARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OFELECTRICAL EQUIPMENT.-IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION CATEGORY "C3"AND "HIGH SYSTEM EXPOSURE")
TIA 607 COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS TELCORDIA GR-63 NETWORKEQUIPMENT-BUILDING SYSTEM (NEBS): PHYSICAL PROTECTIONTELCORDIA GR-347 CENTRAL OFFICE POWER WIRINGTELCORDIA GR-1275 GENERAL INSTALLATION REQUIREMENTSTELCORDIA GR-1503 COAXIAL CABLE CONNECTIONS
ANY AND ALL OTHER LOCAL & STATE LAWS AND REGULATIONS
FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OROTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND ASPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN.
GENERAL CONSTRUCTION NOTES:
APPLICABLE CODES, REGULATIONS AND STANDARDS:
ABBREVIATIONS
SYMBOLS LEGEND
OFFICE101 ROOM NUMBER
WALL TYPE MARK
KEYNOTE,CONSTRUCTION ITEM
KEYNOTE,DIMENSION ITEM
ROOM NAME
WALL SECTION
DETAIL
3
BLDG. SECTIONA-3001
A-500D5
A-310A5
A-113C1
A-113C4
A-113A1
A-113A4 ELEVATION
3
2
CENTERLINE
ELEVATION DATUM
TILT-UP PANEL MARK
WINDOW SYMBOL
DOOR SYMBOL
PROPERTY LINE
3
±0"
001
10
A GRID/COLUMN LINE
A-3001
A.B. ANCHOR BOLTABV. ABOVEACCA ANTENNA CABLE COVER ASSEMBLYADD'L ADDITIONALA.F.F. ABOVE FINISHED FLOORA.F.G. ABOVE FINISHED GRADEALUM. ALUMINUMALT. ALTERNATEANT. ANTENNAAPPRX. APPROXIMATE(LY)ARCH. ARCHITECT(URAL)AWG. AMERICAN WIRE GAUGEBLDG. BUILDINGBLK. BLOCKBLKG. BLOCKINGBM. BEAMB.N. BOUNDARY NAILINGBTCW. BARE TINNED COPPER WIREB.O.F. BOTTOM OF FOOTINGB/U BACK-UP CABINETCAB. CABINETCANT. CANTILEVER(ED)C.I.P. CAST IN PLACECLG. CEILINGCLR. CLEARCOL. COLUMNCONC. CONCRETECONN. CONNECTION(OR)CONST. CONSTRUCTIONCONT. CONTINUOUSd PENNY (NAILS)DBL. DOUBLEDEPT. DEPARTMENTD.F. DOUGLAS FIRDIA. DIAMETERDIAG. DIAGONALDIM. DIMENSIONDWG. DRAWING(S)DWL. DOWEL(S)EA. EACHEL. ELEVATIONELEC. ELECTRICALELEV. ELEVATOREMT. ELECTRICAL METALLIC TUBINGE.N. EDGE NAILENG. ENGINEEREQ. EQUALEXP. EXPANSIONEXST.(E) EXISTINGEXT. EXTERIORFAB. FABRICATION(OR)F.F. FINISH FLOORF.G. FINISH GRADEFIN. FINISH(ED)FLR. FLOORFDN. FOUNDATIONF.O.C. FACE OF CONCRETEF.O.M. FACE OF MASONRYF.O.S. FACE OF STUDF.O.W. FACE OF WALLF.S. FINISH SURFACEFT.( ' ) FOOT (FEET)FTG. FOOTINGG. GROWTH (CABINET)GA. GAUGEGI. GALVANIZE(D)G.F.I. GROUND FAULT CIRCUIT INTERRUPTERGLB. (GLU-LAM) GLUE LAMINATED BEAMGPS GLOBAL POSITIONING SYSTEMGRND. GROUNDHDR. HEADERHGR. HANGERHT. HEIGHTICGB. ISOLATED COPPER GROUND BUS
IN. ( " ) INCH(ES)INT. INTERIORLB.(#) POUND(S)L.B. LAG BOLTSL.F. LINEAR FEET (FOOT)L. LONG(ITUDINAL)MAS. MASONRYMAX. MAXIMUMM.B. MACHINE BOLTMECH. MECHANICALMFR. MANUFACTURERMIN. MINIMUMMISC. MISCELLANEOUSMTL. METAL(N) NEWNO.(#) NUMBERN.T.S. NOT TO SCALEO.C. ON CENTEROPNG. OPENINGP/C PRECAST CONCRETEPCS PERSONAL COMMUNICATION SERVICESPLY. PLYWOODPPC POWER PROTECTION CABINETPRC PRIMARY RADIO CABINETP.S.F. POUNDS PER SQUARE FOOTP.S.I. POUNDS PER SQUARE INCHP.T. PRESSURE TREATEDPWR. POWER (CABINET)QTY. QUANTITYRAD.(R) RADIUSREF. REFERENCEREINF. REINFORCEMENT(ING)REQ'D/ REQUIREDRGS. RIGID GALVANIZED STEELSCH. SCHEDULESHT. SHEETSIM. SIMILARSPEC. SPECIFICATIONSSQ. SQUARES.S. STAINLESS STEELSTD. STANDARDSTL. STEELSTRUC. STRUCTURALTEMP. TEMPORARYTHK. THICK(NESS)T.N. TOE NAILT.O.A. TOP OF ANTENNAT.O.C. TOP OF CURBT.O.F. TOP OF FOUNDATIONT.O.P. TOP OF PLATE (PARAPET)T.O.S. TOP OF STEELT.O.W. TOP OF WALLTYP. TYPICALU.G. UNDER GROUNDU.L. UNDERWRITERS LABORATORYU.N.O. UNLESS NOTED OTHERWISEV.I.F. VERIFY IN FIELDW WIDE (WIDTH)w/ WITHWD. WOODW.P. WEATHERPROOFWT. WEIGHTC CENTERLINEP PLATE, PROPERTY LINE
GROUT OR PLASTER
(E) BRICK
(E) MASONRY
CONCRETE
EARTH
GRAVEL
PLYWOOD
SAND
PLYWOOD
SAND
(E) STEEL
MATCH LINE
GROUND CONDUCTOR
TELEPHONE CONDUIT
POWER CONDUIT
COAXIAL CABLE
CHAIN LINK FENCE
OVERHEAD SERVICE CONDUCTORSOH
LL
WOOD FENCE
(P) ANTENNA
(P) RRU
(P) DC SURGE SUPRESSION
(F) ANTENNA
(F) RRU
(E) EQUIPMENT
GENERAL NOTES
GN-1
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
SIR FRANCES DRAKE BLVD.
APN: 109-270-08
ENLARGED SITEPLAN
1A-1.2
PROPOSED AT&T 20'-0" WIDE NON-EXCLUSIVEACCESS AND UTILITY EASEMENT
PROPOSED AT&T FIRE TURNAROUND
EXISTING ELECTRICAL POLE WITHTRANSFORMER, PROPOSED AT&T POWER P.O.F.
EXISTING OVERHEAD UTILITY LINES
EXISTING JOINT UTILITY POLE,PROPOSED AT&T TELCO P.O.F.
PROPOSED AT&T 6'-0" WIDENON-EXCLUSIVE ACCESS AND
UTILITY EASEMENT
EXISTING DIRT ROAD, PROPOSED AT&T 20'-0"WIDE ALL-WEATHER GRAVEL ACCESS ROAD
PROPERTY LINE
EXISTING EDGE OF PAVEMENT
NOTE: THE PROPOSED AT&T LEASE AREAS AND GRAVELACCESS ROAD GRADING PLANS TO BE PROVIDED BY ALICENSED CIVIL ENGINEER. FINAL ROUTE OF THE ACCESSROAD TO BE DETERMINED BY CIVIL ENGINEER. FINALACCESS ROUTE WILL DETERMINE WHAT EXISTING TREES OROTHER LANDSCAPING TO BE REMOVED OR REPLACED.
PROPOSED AT&T UNDERGROUND POWER(CONDUIT LENGTH = ±365'-0")
PROPOSED AT&T UNDERGROUND TELCO(CONDUIT LENGTH = ±305'-0")
1 1"=20'OVERALL SITE PLAN
NORTH
PL
AN
N
OR
TH
1" = 20.0'
5'0' 50'25'
EXISTING GUY WIRES
EXISTING GUYED WOOD
89'-4"96'-2
"
116'-
6"
116'-10"
EXISTING WOOD GUY WIRE POST
EXISTING WOOD GUY WIRE POST
EXISTING WOOD GUY WIRE POST TO BEREMOVED
OVERALL SITEPLAN
A-1.1
ALL PROPERTY BOUNDARIES, ORIENTATION OF TRUE NORTH ANDSTREET HALF-WIDTHS HAVE BEEN OBTAINED FROM A TAX PARCELMAP AND EXISTING DRAWINGS AND ARE APPROXIMATE.
NOTES:
1. NO GRADING OR PERMANENT CONSTRUCTION SHALLOCCUR WITHIN DRIP LINES OF TREES THAT ARE TO REMAINWITHOUT ARBORIST APPROVAL.
2. PRIOR TO CONSTRUCTION, GENERAL CONTRACTOR TOCONTACT DIGALERT TO MARK OUT EXISTING UNDERGROUNDUTILITIES. IN THE EVENT OF CONFLICTS, CONTRACTOR TOCONTACT PDC.
THIS IS NOT A SITE SURVEY
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
1 1/4" = 1'-0"ENLARGED SITE PLAN
NORTH
PL
AN
N
OR
TH
1/4" = 1'-0"
1'0' 10'5'
ANTENNA LAYOUT PLAN1
A-3.1
PROPOSED AT&T MONOPOLE
PROPOSED AT&T CABLE PROTECTIONCOVER AT BASE OF NEW MONOPOLE
EXISTING GUYED WOOD POLE TO BEREMOVED
EXISTING / DEMOLITION PLAN1
A-2.1
EQUIPMENT LAYOUT PLAN1
A-2.2
PROPOSED AT&T 10'-0" WIDE NON-EXCLUSIVEACCESS & UTILITY EASEMENT
PROPOSED AT&T UNDERGROUND HYBRIDCONDUITS
PROPOSED AT&T UNDERGROUND POWER(CONDUIT LENGTH = ±365'-0")
PROPOSED AT&T UNDERGROUND TELCO(CONDUIT LENGTH = ±305'-0")
PROPOSED AT&T 20'-0" WIDE NON-EXCLUSIVEACCESS & UTILITY EASEMENT
PROPOSED AT&T 20'-0" WIDE ALL-WEATHERGRAVEL ACCESS ROAD
PROPOSED AT&T KNOX BOXMOUNTED ON EXISTING FENCE
EXISTING ACCESS GATE,PROPOSED AT&T ACCESS
EXISTING GUY WIRE TO BE REMOVED
EXISTING CHAIN LINK FENCE AROUNDEXISTING COMPOUND
EXISTING GUY WIRE TO BE REMOVED
EXISTING WOOD GUY WIRE POST
EXISTING GUY WIRE
ENLARGED SITEPLAN
A-1.2
NOTES:
1. NO GRADING OR PERMANENT CONSTRUCTION SHALLOCCUR WITHIN DRIP LINES OF TREES THAT ARE TO REMAINWITHOUT ARBORIST APPROVAL.
2. PRIOR TO CONSTRUCTION, GENERAL CONTRACTOR TOCONTACT DIGALERT TO MARK OUT EXISTING UNDERGROUNDUTILITIES. IN THE EVENT OF CONFLICTS, CONTRACTOR TOCONTACT PDC.
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
1 1/2" = 1'-0"EQUIPMENT LAYOUT PLAN
NORTH
PL
AN
N
OR
TH
1/4" = 1'-0"
1'0' 10'5'
23'-4" EXISTING SHELTER
8"19
'-5" I
NTE
RIO
R O
F EX
ISTIN
G S
HELT
ER±1
1"
8" 8"9'-5" INTERIOR OF EXISTING SHELTER 8" 11'-11" INTERIOR OF EXISTING GENERATOR ROOM
±11"
8"8'
-4" I
NTE
RIO
R O
F EX
ISTIN
G G
ENER
ATO
R RO
OM
8"10
'-5" I
NTE
RIO
R O
F EX
ISTIN
G S
HELT
ER
EXISTING EQUIPMENT
EXISTING SERVICE METER TO BE REMOVED
EXISTING EQUIPMENT RACK
EXISTING CABLE TRAY
EXISTING EQUIPMENTTO BE REMOVED
EXISTING GENERATOR TO BE REMOVED
EXISTING EQUIPMENT TO BEREMOVED
EXISTING DOOR
EXISTING CONCRETE PATIO W/WOOD FRAMED COVER
EXISTING EQUIPMENT SHELTER
EXISTING EQUIPMENTTO BE REMOVED
EXISTING EQUIPMENTRACK
EXISTING ELECTRICAL PANEL TO BEUPGRADED
EXISTING DOOR
EXISTING EQUIPMENT TO BE REMOVED
EXISTING EXHAUST FAN
8" 8"22'-0" INTERIOR OF EXISTING SHELTER
21'-0
" EXI
STIN
G S
HELT
ER
EXISTING /DEMOLITION
PLAN
A-2.1
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
1 1/2" = 1'-0"EQUIPMENT LAYOUT PLAN
NORTH
PL
AN
N
OR
TH
1/4" = 1'-0"
1'0' 10'5'
23'-4" PROPOSED AT&T LEASE AREA
8" 8"22'-0" INTERIOR OF EXISTING SHELTER
5'-0" 5'-6" UNISTRUT H-FRAME 11'-6"
21'-0
" PRO
POSE
D A
T&T
LEA
SE A
REA
8"19
'-5" I
NTE
RIO
R O
F EX
ISTIN
G S
HELT
ER
14'-5
"
±11"
4'-0
"UN
ISTR
UT H
-FRA
ME
1'-0
"
23'-4" PROPOSED AT&T LEASE AREA
8" 8"9'-5" INTERIOR OF EXISTING SHELTER
3"
8" 11'-11" INTERIOR OF EXISTING GENERATOR ROOM
7'-9" GENERATOR3'-11"
21'-0
" PRO
POSE
D A
T&T
LEA
SE A
REA
11"
8"8'
-4" I
NTE
RIO
R O
F EX
ISTIN
G G
ENER
ATO
R RO
OM
8"10
'-5" I
NTE
RIO
R O
F EX
ISTIN
G S
HELT
ER
PROPOSED AT&T 400A MULTI-METER ONEXISTING EXTERIOR WALL
PROPOSED AT&T 200A SERVICE METER ONNEW MULTI-METER
PROPOSED AT&T 24"x24"x8" HOFFMANTELCO BOX WITH CIENA BOX ABOVEMOUNTED ON A UNISTRUT H-FRAME
EXISTING CABLE TRAY TO BERE-USED BY AT&T
PROPOSED AT&T POWER PLANT
PROPOSED AT&T TELCO RACK
PROPOSED AT&T UMTS/LTERACK
(3) PROPOSED AT&T SURGE PROTECTORSMOUNTED ON A UNISTRUT H-FRAME
(VERTICALLY STACKED)
(4) PROPOSED AT&T 6"Ø CONDUITSTUB-UPS AT SURGE PROTECTORS
PROPOSED AT&T CAM-LOK GENERATORINTERFACE MOUNTED ON UNISTRUT
PROPOSED AT&T 30KW DIESEL GENERATORWITH A 190 GALLON FUEL TANK
EXISTING DOOR, PROPOSEDAT&T ACCESS DOOR
EXISTING DOOR, PROPOSEDAT&T ACCESS DOOR
PROPOSED AT&T PORTABLE FIRE EXTINGUISHER ONUTILITY H-FRAME. INSTALL IN WEATHERPROOFCABINET & LABEL. THE EXTINGUISHER SHALL BE RATED4A:80B:C OR AS REQUIRED BY LOCAL FIRE AUTHORITY
EXISTING CONCRETE PATIO W/WOOD FRAMED COVER
EXISTING EQUIPMENT SHELTER
PROPOSED AT&T ELECTRICALINTERSECT CABINET MOUNTEDON A UNISTRUT H-FRAME
PROPOSED AT&T UNISTRUT H-FRAME ONEXISTING INTERIOR WALL (TYP.)
EXISTING ELECTRICALPANEL TO BE UPGRADED
EXISTING EQUIPMENT RACKS
EXISTING EQUIPMENT
EQUIPMENTLAYOUT PLAN
A-2.2
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
NO SCALERF SCHEDULE3
1/2" = 1'-0" ANTENNA LAYOUT PLAN AT 50.0' A.G.L.1
5' 10'1'
1/2" = 1'-0"
0'
SECTOR CAZIMUTH 120°
NORTH
PL
AN
N
OR
TH
SEC
TOR
AA
ZIM
UTH
0°
SECTORALPHA
BETA
GAMMA
ANTENNA MODEL NO. AZIMUTH CENTERLINE RRH FIBER LENGTH COAX LENGTH JUMPER TYPE RRU NO.
RF SCHEDULE
± 42'-0"
TMA
0°
240°
A1
A2
A3
B1
B2
B3
C1
C2
C3
± 75'-0" (2)
(1)
(1)
120°
CCI - OPA45R-BU5C -
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LDF4
LDF4
LDF4
LDF4
LDF4
LDF4
LDF4
LDF4
LDF4
RF DATA SHEET v1.00 DATED 05/30/2019 EQUIPMENT IS PRELIMINARY AND SUBJECT TO CHANGE.NOTE: ANTENNA POSITIONS ARE LEFT TO RIGHT FROM FRONT OF ANTENNA
(1) 4449 B5/B12 / (1) 8843 B2/B66
(1) 4478 B14
(1) 4415 B30
(2)
(1)
(1)
(2)
(1)
(1)
(1) 4449 B5/B12 / (1) 8843 B2/B66
(1) 4478 B14
(1) 4415 B30
(1) 4449 B5/B12 / (1) 8843 B2/B66
(1) 4478 B14
(1) 4415 B30
± 75'-0"
± 75'-0"
± 75'-0"
± 75'-0"
± 75'-0"
± 75'-0"
± 75'-0"
± 75'-0"
0°
0°
240°
240°
120°
120°
CCI - OPA45R-BU5C
CCI - OPA45R-BU5C
CCI - OPA45R-BU5C
CCI - OPA45R-BU5C
CCI - OPA45R-BU5C
CCI - OPA45R-BU5C
CCI - OPA45R-BU5C
CCI - OPA45R-BU5C
± 50'-0"
± 50'-0"
± 50'-0"
± 50'-0"
± 50'-0"
± 50'-0"
SECTOR B
AZIMUTH 240°
DELTA
D1
D2
D3
-
-
-
-
-
-
LDF4
LDF4
LDF4
(2)
(1)
(1)
(1) 4449 B5/B12 / (1) 8843 B2/B66
(1) 4478 B14
(1) 4415 B30
± 75'-0"
± 75'-0"
± 75'-0"
CCI - OPA45R-BU5C
CCI - OPA45R-BU5C
CCI - OPA45R-BU5C
± 50'-0"
± 50'-0"
± 50'-0"
60°
60°
60°
SECTOR D
AZIMUTH 60°
± 42'-0"
± 42'-0"
1/2" = 1'-0" ANTENNA LAYOUT PLAN AT 42.0' A.G.L.2
5' 10'1'
1/2" = 1'-0"
0'NORTH
PL
AN
N
OR
TH
3'-0" TYP.3'-0" TYP.
7'-0" TYP.
6"6"
3'-0" TYP.
3'-0" TYP.
7'-0" TYP.6"
6"
(4) PROPOSED AT&T SURGESUPPRESSORS, (1) PERSECTOR
2A-3.2
(16) PROPOSED AT&T RRUS,(4) RRUS PER SECTOR
SHEETA-3.3
(12) PROPOSED AT&TANTENNAS, (3) PER SECTOR
1A-3.2PROPOSED AT&T
TRI-COLLARMOUNT
PROPOSED AT&TMONOPOLE
(4) PROPOSED AT&T HEAVYDUTY ANTENNA SECTORFRAMES, (1) PER SECTOR
(4) PROPOSED AT&T SURGESUPPRESSORS, (1) PER
SECTOR
2A-3.2
(16) PROPOSED AT&T RRUS,(4) RRUS PER SECTOR
SHEETA-3.3
(12) PROPOSED AT&TANTENNAS, (3) PER SECTOR
1A-3.2
(4) PROPOSED AT&T HEAVYDUTY ANTENNA SECTORFRAMES, (1) PER SECTOR
FUTURE AT&T MICROWAVEDISH (SIZE, AZIMUTH, AND
LOCATION TO BE DETERMINED
PROPOSED AT&TTRI-COLLAR MOUNT
PROPOSED AT&TMONOPOLE
4A-3.2
3A-3.2
3A-3.2
4A-3.210'-0" PROPOSED AT&T LEASE AREA
10'-0
" PRO
POSE
D AT
&T LE
ASE
AREA
5'-0"
EXISTING GUYED WOODPOLE TO BE REMOVED
ANTENNALAYOUT PLANS
A-3.1
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
2-1/4" STANDARDGALVINIZED PIPE MOUNT
11"
11"
9"2'
-3"
GROUND TO ANTENNA GROUNDBAR OR BUILDING STEEL
SURGE SUPPRESSION SYSTEMFOR USE AT ANTENNA SECTORSCLOSER THAN 18 FEET APART
MFR STANDARD CLIPS
2-1/4" STANDARDGALVINIZED PIPE MOUNT
MFR STANDARD PIPEMOUNT HARDWARE
RAYCAP DC6-48-60-18-8F & DC6-48-60-0-8F SURGE SUPPRESSION SOLUTION
COLOR: BLACK/SILVER
DIMENSIONS: 11" DIA X 27" TALL W/ 9" BASE
WEIGHT: +/- 50 LBS. (INCLUDING MOUNTING HARDWARE)
SURGE SUPPRESSION SYSTEMFOR USE AT ANTENNA SECTORSCLOSER THAN 18 FEET APART
COAX LINES TO ANTENNAS
MFR STANDARDPIPE MONTHARDWARE
2 1-1/2"= 1'-0"DC SURGE SUPRESSION (SQUID)
VFA10-HDSECTOR FRAME
GALV. STL. MOUNTINGPIPES. LENGTH ASREQUIRED
NO SCALESITEPRO SECTOR FRAME VFA10-HD4
55"
==
8.5"29.1"
ANTENNASUPPORT PIPE
MECHANICALDOWNTILT
BRACKET
ANTENNAWEIGHTDIMENSIONS
CCI (OPA45R-BU5C)64.6 LBS55.0" (H) x 29.1" (W) x 8.5" (D)=
1 3/4" = 1'-0"PROPOSED ANTENNA SPEC
FRONT SIDE PERSPECTIVE
EQUIPMENT SUBJECT TO CHANGE
3 3/4" = 1'-0"PROPOSED MONOPOLE SECTOR FRAME ATTACHMENT
==
MODEL NO.WEIGHTPOLE DIA.
SITEPRO1 (MSFAA)788.53 LBS12" - 45"=
RING MOUNTWELDMENT
4-1/2"x72" SCH. 40GALV. STL PIPE
ANTENNADETAILS
A-3.2
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
3 1-1/2"= 1'-0"ERICSSON RADIO 4449 B5/B12 REMOTE RADIO UNIT
4 1-1/2"= 1'-0"ERICSSON RADIO 8843 B2/B66A REMOTE RADIO UNIT
FRONT VIEW SIDE VIEW
TOP VIEW
2 1-1/2"= 1'-0"ERICSSON RADIO 4415 B25/B30 REMOTE RADIO UNIT
ERICSSON RADIO 4415 B25 REMOTE RADIO UNIT
COLOR: WHITE
DIMENSIONS: 16.5" TALL X 13.4" WIDE X 5.9" DEEP (INCLUDING SUNSHIELD)
WEIGHT: 46 LBS.± (INCLUDING MOUNTING HARDWARE)
4415 B25 WITH SUNSHIELD
1 1-1/2"= 1'-0"ERICSSON RADIO 4478 B14 REMOTE RADIO UNIT
16.5
"12
"C
LR
13.4"
16"
CLR 5.9"
2-3/8" DIA. GALV.STL. PIPE (LENGTHAS REQUIRED)
ERICSSON GALV.STL. MOUNTINGBRACKETS PART #:SXK 125 0245/1
(2) 3/8"Ø GALV.STL. BOLTS, NUTS &LOCK WASHERS
(2) 3/8"Ø GALV.STL. BOLTS, NUTS &LOCK WASHERS
5.9"
13.4
"
ERICSSON RRH 4478 B14 REMOTE RADIO UNIT
COLOR: WHITE
DIMENSIONS: 16.5" TALL X 13.4" WIDE X 7.7" DEEP (INCLUDING SUNSHIELD)
WEIGHT: +/- 59.9 LBS. (INCLUDING MOUNTING HARDWARE)
FRONT VIEW
16"
CLR
12"
CLR
RRH 4478 B14 WITH SUNSHIELD
MFR'S STANDARDMOUNTING BRACKETS
ERICSSON RADIO 4449 B5/B12 REMOTE RADIO UNIT
COLOR: WHITE
DIMENSIONS: 15" TALL X 13.2" WIDE X 10.2" DEEP (INCLUDING SUNSHIELD)
WEIGHT: 75 LBS± (INCLUDING MOUNTING HARDWARE)
SIDE VIEW
16"
CLR
RADIO 4449WITH SUNSHIELD
MFR'S STANDARDMOUNTING BRACKETS
MFR'S STANDARDMOUNTING
BRACKETS
ERICSSON RADIO 8843 B2/B66A REMOTE RADIO UNIT
13.2"
15.0
"
FRONT VIEW
BOTTOM VIEW
15.0
"
10.2"
13.4
"
13.4"
7.7"
16.5
"
BOTTOM VIEW
SIDE VIEW
PIPE
MANUFACTURERSUPPLIEDMOUNTINGBRACKET
10.2"
12"
CLR
COLOR: WHITE
DIMENSIONS: 15" TALL X 13.2" WIDE X 10.2" DEEP (INCLUDING SUNSHIELD)
WEIGHT: 75 LBS± (INCLUDING MOUNTING HARDWARE)
SIDE VIEW
16"
CLR
RADIO 4449WITH SUNSHIELD
MFR'S STANDARDMOUNTING BRACKETS
MFR'S STANDARDMOUNTING
BRACKETS
13.2"
15.0
"
FRONT VIEW
BOTTOM VIEW
15.0
"
10.2"
10.2"
12"
CLR
5 1-1/2"= 1'-0"BACK TO BACK RRH MOUNTING (COMMSCOPE PART#: RR-B2B-AR)
SIDE VIEWFRONT VIEW
TOP VIEW
SPECIFICATIONS:
MATERIAL: HOT-DIPPED GALVANIZED STEEL
DIMENSIONS:HEIGHT: 13.4 INWIDTH: 8.4 IN.LENGTH: 18.2 IN.
WEIGHT: 39 LBS± (INCLUDINGMOUNTING HARDWARE)
RRH DETAILS
A-3.3
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
EXISTING GRADE0.0' A.G.L. (551.5' A.M.S.L.)
TOP OF PROPOSED MONOPOLE54.0' A.G.L.
CENTERLINE OF PROPOSED ANTENNAS50.0' A.G.L.
1 1/4" = 1'-0"NORTHEAST ELEVATION
CENTERLINE OF PROPOSED ANTENNAS42.0' A.G.L.
PROPOSED AT&T ANTENNAS W/ASSOCIATED TOWER-MOUNTEDEQUIPMENT
EXISTING CHAIN LINK FENCE AROUNDEXISTING COMPOUND BEYOND
EXISTING EQUIPMENT SHELTER
PROPOSED AT&T MONOPOLE
PROPOSED AT&T 400A MULTI-METERON EXISTING EXTERIOR WALL
PROPOSED AT&T CABLEPROTECTION COVER
EXISTING GUYED WOOD POLE TOBE REMOVED
PROPOSEDELEVATION
A-4.1
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
EXISTING GRADE0.0' A.G.L. (551.5' A.M.S.L.)
TOP OF PROPOSED MONOPOLE54.0' A.G.L.
CENTERLINE OF PROPOSED ANTENNAS50.0' A.G.L.
1 1/4" = 1'-0"SOUTHEAST ELEVATION
CENTERLINE OF PROPOSED ANTENNAS42.0' A.G.L.
PROPOSED AT&T ANTENNAS W/ ASSOCIATEDTOWER-MOUNTED EQUIPMENT
PROPOSED AT&T MONOPOLE
EXISTING CHAIN LINK FENCE AROUNDEXISTING COMPOUND BEYOND
EXISTING EQUIPMENT SHELTER
EXISTING GUYED WOOD POLE TO BEREMOVED
PROPOSEDELEVATION
A-4.2
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
EXISTING GRADE0.0' A.G.L. (551.5' A.M.S.L.)
TOP OF PROPOSED MONOPOLE54.0' A.G.L.
CENTERLINE OF PROPOSED ANTENNAS50.0' A.G.L.
1 1/4" = 1'-0"SOUTHWEST ELEVATION
CENTERLINE OF PROPOSED ANTENNAS42.0' A.G.L.
FUTURE AT&T MICROWAVE DISH(SIZE, AZIMUTH, AND LOCATION
TO BE DETERMINED
PROPOSED AT&T ANTENNAS W/ASSOCIATED TOWER-MOUNTED
EQUIPMENT
EXISTING CHAIN LINK FENCE AROUNDEXISTING COMPOUND BEYOND
EXISTING EQUIPMENT SHELTER
PROPOSED AT&T MONOPOLE
PROPOSED AT&T CABLEPROTECTION COVER
EXISTING GUYED WOOD POLE TOBE REMOVED
PROPOSEDELEVATION
A-4.3
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2
EXISTING GRADE0.0' A.G.L. (551.5' A.M.S.L.)
TOP OF PROPOSED MONOPOLE54.0' A.G.L.
CENTERLINE OF PROPOSED ANTENNAS50.0' A.G.L.
1 1/4" = 1'-0"NORTHWEST ELEVATION
CENTERLINE OF PROPOSED ANTENNAS42.0' A.G.L.
FUTURE AT&T MICROWAVE DISH (SIZE,AZIMUTH, AND LOCATION TO BE DETERMINED
PROPOSED AT&T ANTENNAS W/ ASSOCIATEDTOWER-MOUNTED EQUIPMENT
PROPOSED AT&T MONOPOLE
EXISTING CHAIN LINK FENCE AROUNDEXISTING COMPOUND BEYOND
EXISTING EQUIPMENT SHELTERPROPOSED AT&T CABLEPROTECTION COVER
EXISTING GUYED WOOD POLE TO BEREMOVED
PROPOSEDELEVATION
A-4.4
PREPARED FOR
REV DESCRIPTIONDATE
SHEET TITLE:
SHEET NUMBER:
CHECKED BY:
DRAWN BY:
PROJECT NO:
IT IS A VIOLATION OF LAW FOR ANYPERSON, UNLESS THEY ARE ACTING
UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS
DOCUMENT.
Vendor:
Licensee:
Architect:
AT&T SITE NO:
162.2528
CCL02454
1520 River Park DriveSacramento, California 95815
07/09/19 90% ZD
2600 Camino RamonSan Ramon, California 94583
Issued For:
CCL02454POINT REYESLIFEBOAT STN
SIR FRANCIS DRAKE BLVD.INVERNESS, CA. 94937
MWS
TST
08/07/19 100% ZD01/17/20 100% ZD REV 106/19/20 100% ZD REV 2