AXL 966GII WHEEL LOADER Troubleshooting Media Number RENR4387-07 Publication Date 2003/10/01 Update Date 2003/10/07
Diagnostic Code List SMCS Code: 7569
Table 4
Component Identifier (CID) Transmission ECM (MID 081)
For troubleshooting, see the procedure with the same diagnostic code.
CID and FMI Component
CID 0041 Sensor Supply Voltage
FMI 03 Voltage above normal or shorted high
FMI 04 Voltage below normal or shorted low
CID 0149 Solenoid Valve (Ride Control) FMI 03 Voltage above normal or shorted high
FMI 05 Current below normal or open circuit
FMI 06 Current above normal or grounded circuit
CID 0168 Electrical System Voltage
FMI 00 Data valid but above the normal operational range
FMI 01 Data valid but below normal operational range
CID 0177 Temperature Sensor (Transmission Oil) FMI 03 Voltage above normal or shorted high
FMI 04 Voltage below normal or shorted low
CID 0190 Speed Sensor (Engine) FMI 02 Data erratic, intermittent, or incorrect
CID 0363 Solenoid Valve (Ride Control) FMI 03 Voltage above normal or shorted high
FMI 05 Current below normal or open circuit
FMI 06 Current above normal or grounded circuit
CID 0367 Rocker Switch (Ride Control) FMI 03 Voltage above normal or shorted high
CID 0368 Transmission Auto/Manual Switch
Page 1 of 4Copyright 1991, 2013 Caterpillar Inc. All Rights Reserved.
25/05/2013file://C:\SIS\TMP\sis167A1prt.html
FMI 03 Voltage above normal or shorted high
FMI 04 Voltage below normal or shorted low
CID 0444 Magnetic Switch (Start Relay) FMI 03 Voltage above normal or shorted high
FMI 05 Current below normal or open circuit
FMI 06 Current above normal or grounded circuit
CID 0562 Caterpillar Monitoring System
FMI 09 Abnormal update
CID 0585 Speed Sensor (Transmission Output 1) FMI 02 Data erratic, intermittent, or incorrect
CID 0621 Push button Switch (Downshift) FMI 03 Voltage above normal or shorted high
FMI 04 Voltage below normal or shorted low
CID 0622 Push button Switch (Upshift) FMI 03 Voltage above normal or shorted high
FMI 04 Voltage below normal or shorted low
CID 0623 Rocker Switch (Transmission Direction) FMI 03 Voltage above normal or shorted high
FMI 04 Voltage below normal or shorted low
CID 0627 Pressure Switch (Parking Brake) FMI 03 Voltage above normal or shorted high
FMI 04 Voltage below normal or shorted low
CID 0650 Harness Code
FMI 09 Abnormal update
FMI 12 Failed
CID 0668 Transmission Control Lever
FMI 02 Data erratic, intermittent, or incorrect
CID 0672 Speed Sensor (Torque Converter output) FMI 02 Data erratic, intermittent, or incorrect
CID 0673 Speed Sensor No. 2 (Transmission Output) FMI 02 Data erratic, intermittent, or incorrect
CID 0793 Pressure Switch (Primary Steering Oil)
Page 2 of 4Copyright 1991, 2013 Caterpillar Inc. All Rights Reserved.
25/05/2013file://C:\SIS\TMP\sis167A1prt.html
FMI 03 Voltage above normal or shorted high
FMI 04 Voltage below normal or shorted low
CID 0794 Pressure Switch (Secondary Steering Oil) FMI 03 Voltage above normal or shorted high
FMI 04 Voltage below normal or shorted low
FMI 07 Improper Responce
CID 0795 Relay (Secondary Steering Intermediate) FMI 03 Voltage above normal or shorted high
FMI 05 Current below normal or open circuit
FMI 06 Current above normal or grounded circuit
FMI 07 Improper Responce
CID 1327 Position Sensor (Left Brake Pedal) FMI 00 Data valid but above normal operational range
FMI 01 Data valid but below normal operational range
FMI 03 Voltage above normal or shorted high
FMI 04 Voltage below normal or shorted low
FMI 13 Out of calibration
CID 1401 Modulating Valve (No. 1) (Transmission) FMI 03 Voltage above normal or shorted high
FMI 05 Current below normal or open circuit
FMI 06 Current above normal or grounded circuit
FMI 13 Out of calibration
CID 1402 Modulating Valve (No. 2) (Transmission) FMI 03 Voltage above normal or shorted high
FMI 05 Current below normal or open circuit
FMI 06 Current above normal or grounded circuit
FMI 13 Out of calibration
CID 1403 Modulating Valve (No. 3) (Transmission) FMI 03 Voltage above normal or shorted high
FMI 05 Current below normal or open circuit
FMI 06 Current above normal or grounded circuit
Page 3 of 4Copyright 1991, 2013 Caterpillar Inc. All Rights Reserved.
25/05/2013file://C:\SIS\TMP\sis167A1prt.html
Copyright 1991, 2013 Caterpillar Inc. All Rights Reserved.
Out of calibration
CID 1404 Modulating Valve (No. 4) (Transmission) FMI 03 Voltage above normal or shorted high
FMI 05 Current below normal or open circuit
FMI 06 Current above normal or grounded circuit
FMI 13 Out of calibration
CID 1405 Modulating Valve (No. 5) (Transmission) FMI 03 Voltage above normal or shorted high
FMI 05 Current below normal or open circuit
FMI 06 Current above normal or grounded circuit
FMI 13 Out of calibration
CID 1406 Modulating Valve (No. 6) (Transmission) FMI 03 Voltage above normal or shorted high
FMI 05 Current below normal or open circuit
FMI 06 Current above normal or grounded circuit
FMI 13 Out of calibration
CID 1521 Rotary Switch (Variable Shift Control) FMI 03 Voltage above normal or shorted high
FMI 04 Voltage below normal or shorted low
Page 4 of 4Copyright 1991, 2013 Caterpillar Inc. All Rights Reserved.