SIS Software Install Instructions Cookbook Multibeam Advisory
Committee March 21, 2012 SIS 3.8.3 1 Multibeam Advisory Committee
March 21, 2012
Slide 2
Contents How to install SIS software Configure the datagram
distribution software NOTE: These are directions for installing the
SIS software. If you are doing this to replace a corrupt database,
please see the SIS Configuration Backup and SIS Software Uninstall
cookbook. 2 Multibeam Advisory Committee March 21, 2012
Slide 3
SIS Software Install Insert the SIS software DVD. If a window
does not automatically open, browse to the DVD using a file
explorer and double click on the start.html file. Click on the SIS
SW Installation Link. Click Here 3 Multibeam Advisory Committee
March 21, 2012
Slide 4
SIS Software Install Once this SIS Software Installation opens
up, click on the Press here to install Seafloor Information System.
Click Here 4 Multibeam Advisory Committee March 21, 2012
Slide 5
SIS Software Install If a security warning pops up click run to
continue the installation. 5 Multibeam Advisory Committee March 21,
2012
Slide 6
SIS Software Install Choose your install language. 6 Multibeam
Advisory Committee March 21, 2012
Slide 7
SIS Software Install Click on the Next button to continue
installation. 7 Multibeam Advisory Committee March 21, 2012
Slide 8
SIS Software Install Verify that this is the version and build
of SIS you want to install. 8 Multibeam Advisory Committee March
21, 2012
Slide 9
SIS Software Install Make sure that SIS is selected as an
installable component. 9 Multibeam Advisory Committee March 21,
2012
Slide 10
SIS Software Install Choose where you want to store you raw
data and where you want to store your grid data files. 10 Multibeam
Advisory Committee March 21, 2012
Slide 11
SIS Software Install Define the IP number or hostname of the
Database server. If the database is going to be on the same machine
you are running SIS (the normal operation mode) enter localhost. 11
Multibeam Advisory Committee March 21, 2012
Slide 12
SIS Software Install Choose the install location for the SIS
software. The default value of C:\Program Files\Kongsberg
Maritime\SIS\ is the normal install location. 12 Multibeam Advisory
Committee March 21, 2012
Slide 13
SIS Software Install If you want Shortcuts to be put under the
Start menu in a SIS folder simply click Install. Otherwise define a
different folder name or click Do not create shortcuts. Multibeam
Advisory Committee March 21, 2012 13
Slide 14
SIS Software Install During the install process a dialog box
will appear asking about installing a MATLAB compiler runtime,
click OK. Multibeam Advisory Committee March 21, 2012 14
Slide 15
SIS Software Install After the install is done Reboot the
machine to finish the process. Multibeam Advisory Committee March
21, 2012 15
Slide 16
SIS Software Install Restart SIS and reconnect with the TRU
through the pulldown menu. If the TRU does not appear, Rescan, and
select it. Multibeam Advisory Committee March 21, 2012 16
Slide 17
SIS Software Install It is now time to import your PU settings
(offsets, device settings, etc). Under the File menu select Import
PU parameters. Multibeam Advisory Committee March 21, 2012 17
Slide 18
SIS Software Install A dialog box will appear. Browse to the
location you saved you PU parameters (normally in the
E:/sisdata/common/pu_param directory. Select your saved file and
click OK. Multibeam Advisory Committee March 21, 2012 18
Slide 19
SIS Software Install Dont worry if you see plenty of blinking
red fields after doing this. Go to the File menu and select
quit.everything will be ok. Multibeam Advisory Committee March 21,
2012 19
Slide 20
SIS Software Install Start up SIS again and connect to the TRU
through the pulldown menu. Multibeam Advisory Committee March 21,
2012 20
Slide 21
SIS Software Install It is now time to import all of you user
settings such as screen layouts, datagram subscribtions, external
sensors, etc. Go the the File menu and select User settings.
Multibeam Advisory Committee March 21, 2012 21
Slide 22
SIS Software Install You should only load user settings from a
machine with the same number of hard drives. This is not normally a
problem as the usual is to load settings from the same machine.
Click Ok. Multibeam Advisory Committee March 21, 2012 22
Slide 23
SIS Software Install The Import User Settings dialog box will
appear. Click on the file selection box for User Parameters
(circled in the figure above). Multibeam Advisory Committee March
21, 2012 23
Slide 24
SIS Software Install Select the User Settings parameters file.
This file will end in a.params suffix. Multibeam Advisory Committee
March 21, 2012 24
Slide 25
SIS Software Install Click on the file selection box for
Datagram subscriptions. Multibeam Advisory Committee March 21, 2012
25
Slide 26
SIS Software Install Select the Datagram subscriptions file.
This file will end in a.dgmsubs suffix. Multibeam Advisory
Committee March 21, 2012 26
Slide 27
SIS Software Install Click on the file selection box for Survey
templates. Multibeam Advisory Committee March 21, 2012 27
Slide 28
SIS Software Install Select the Survey template file. This file
will end in a.srvtpl suffix. Multibeam Advisory Committee March 21,
2012 28
Slide 29
SIS Software Install Click on the file selection box for
Projections. Multibeam Advisory Committee March 21, 2012 29
Slide 30
SIS Software Install Select the Projections file. This file
will end in a.proj suffix. Make sure you DO NOT select the file
that ends with a.srvtpl.proj suffix. Multibeam Advisory Committee
March 21, 2012 30
Slide 31
SIS Software Install Click on the file selection box for Frame
settings. Multibeam Advisory Committee March 21, 2012 31
Slide 32
SIS Software Install Select the Frames file. This file will end
in a.frames suffix. Multibeam Advisory Committee March 21, 2012
32
Slide 33
SIS Software Install Click on the file selection box for
External sensor settings. Multibeam Advisory Committee March 21,
2012 33
Slide 34
SIS Software Install Select the External Sensors file. This
file will end in a.extsens suffix. Multibeam Advisory Committee
March 21, 2012 34
Slide 35
SIS Software Install Click the Accept button now that you have
filled out all of the fields. Multibeam Advisory Committee March
21, 2012 35
Slide 36
SIS Software Install Click the Accept button. If you are
importing these settings from another sounder make sure that you
change the Sounders serial to match the sounder you are importing
for. Multibeam Advisory Committee March 21, 2012 36
Slide 37
SIS Software Install Click the Ok button, you are done
importing settings. Multibeam Advisory Committee March 21, 2012
37
Slide 38
SIS Software Install Quit SIS in order to finalize the loading
of the User settings. Multibeam Advisory Committee March 21, 2012
38
Slide 39
SIS Software Install Start up SIS again and connect to the TRU
through the pulldown menu. Multibeam Advisory Committee March 21,
2012 39
Slide 40
SIS Software Install The one parameter that the above method
does not correctly set (apparently) is the grid engines cell size.
To fix this select View -> Tear Off -> New Survey. Multibeam
Advisory Committee March 21, 2012 40
Slide 41
SIS Software Install Change the Number of cells in processing
grid: to 128x128 and change the Cell size (m) to 150 for the EM122
and 5 for the EM710. It might be necessary to change to EM710s grid
cell size to 10m depending upon the size of the survey area.
Multibeam Advisory Committee March 21, 2012 41
Slide 42
Datagram Distribution Configuration SIS as part of the install
process wiped out the datagram distribution parameters. Open the
software and add a source port of 4310 for Centerbeam Depth and a
the desired IP and destination port (for the Kilo Moanas EM120 you
should enter 192.168.1.40:5634 and for the EM710 you should enter
192.168.50:5635). Multibeam Advisory Committee March 21, 2012 42
R/V Kilo Moanas EM122 Data Distribution settings. R/V Kilo Moanas
EM710 Data Distribution settings.