SINAMICS G120
The modular converter – energy-efficient, safe and robust
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 2 2012-03-08
SINAMICS G120
SINAMICS G120 Components
+
CU230P-2
IOP BOP-2
PM230 IP20/IP20PT/IP55
PM240 / PM250 / PM260 IP20
PM340 IP20
+
+
CU240B-2 CU240E-2
+ CU240E-2
1AC 200V
3AC 400V
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 3 2012-03-08
SINAMICS G120 5 power modules to address different requirements
Voltage power (LO)
380-480V 0.37 – 90kW
380-480V 0.37 – 250kW
380-480V 7.5 – 90kW
500-690V 11 – 55kW
200-240V 0.12 – 0.75kW
Protection IP20/IP20PT/IP55 IP20 IP20 IP20 IP20 Braking DC-brake resistor regenerative regenerative resistor Harmonics reduced *) standard reduced *) reduced *) standard
Safety Integrated no yes yes yes yes
Output filer --- external external integrated external Dynamic accel. no yes yes yes yes Dynamic decel. no yes (with resistor) yes yes yes (with resistor)
Cable length 25 / 100 25 / 100 **) 25 / 100 **) 200 / 300 50 / 75
PM240 PM250 PM260 PM230
*) according to standard IEC/EN 61000-3-12 – fulfilled without any additional measures **) without output reactor
PM340
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 4 2012-03-08
SINAMICS AC/AC Overview of the Control Units
G120
Control Units:
CU230P-2 HVAC CU230P-2 PN CU230P-2 DP
CU230P-2 CAN
CU240B-2 CU240B-2 DP
CU240E-2 (-F*) CU240E-2 DP (-F*) CU240E-2 PN (-F*)
Control Modes: U/F, FCC, ECO, Vector Control without encoder (SLVC)
U/F, FCC, ECO, Vector Control without encoder (SLVC)
U/F, FCC, ECO, Vector Control without encoder (SLVC)
Power Modules: PM 230**, PM240, PM250, PM260 PM240, PM250, PM260 PM240, PM250, PM260
Safety: - - STO, SDI*, SSM*, SS1*, SLS*, PROFIsafe
Operator Panels: BOP-2, IOP, IOP Handheld BOP-2, IOP, IOP Handheld BOP-2, IOP, IOP Handheld
Technology:
• Free Blocks (FFB) • 4 x PID Controller • Pump Staging • Hibernation • Essential Service Mode • 2-Zone Control
• Free Blocks (FFB) • PID Control • Brake Control
• Free Blocks (FFB) • PID Control • Brake Control
Applications: Pumps, Fans, Compressors, HVAC, Water / Wastewater
(MM430 Migration)
General applications without encoder with brake control up to high power ratings
(MM420 Migration)
General applications like CU240B-2 with additional I/O and Safety Functions
(MM440 Migration)
Communication: PROFINET / PROFIBUS / USS / CAN open / Modbus RTU / BACnet MS/TP PROFIBUS / RS485 / USS / Modbus RTU PROFINET / PROFIBUS / RS485 / USS /
Modbus RTU
* = optional; ** CU230 + PM230 = G120P
The specialist for pumps, fans, compressors, water, buildings
For basic applications with variable-speed drives
For standard applications in general machinery construction, such as
conveyor belts, mixers and extruders
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 5 2012-03-08
SINAMICS G120 CU240E-2 – technical details
Products CU240E-2, CU240E-2 DP, CU240E-2-F, CU240E-2 DP-F
Hardware Safety Integrated STO available in the standard version Safety Integrated STO, SLS, SS1, SDI, SSM available in the -F version PROFIsafe integrated Integrated USB connection for commissioning and diagnosis Available with PROFIBUS or RS485/USS/Modbus RTU connection Isolated RS485 connection increased robustness Drive command set to I/O (RS485 version) or PROFIBUS (DP-version) Improved SLVC control
Identical to MM440: Number of I/Os, digital I/O, can be toggled between NPN – PNP, terminal
connections
Can be used with power modules PM230 IP20, PM240, PM250, PM260, PM340
Supports PM340 1-phase
FSA 0.12-0.75 kW
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 6 2012-03-08
STO (Safe Torque Off) conventionally wired
High wiring time & costs as a result of the safety relay and contactors. No protection against manipulation of the safety functions. Intensive service is required due to the mechanical shutdown (contact us). The power-on cycles of the converter have to be taken into consideration as it is disconnected from the line supply. No diagnostics of the converter as the status display is no longer available after shutdown.
After the Emergency Stop button has been pressed, the contactor safety combination opens the two line contactors K1 and K2 and the motor coasts down unbraked.
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 7 2012-03-08
STO (Safe Torque Off) using the safety digital inputs of SINAMICS G120
After the Emergency Stop pushbutton has been pressed, the firing pulses of the power unit are cancelled in SINAMICS G120 in a safety-relevant fashion and the drive coasts down unbraked. Caution! The motor is not electrically isolated from the line supply.
Cost saving as a result of minimized wiring costs and space-saving as the Emergency Stop pushbutton is directly connected to the SINAMICS G120 digital inputs without using a safety contactor combination.
Risks are minimized for the plant construction company by using password-protected safety parameters in SINAMICS G120.
No wearing parts as the shutdown is electronic. SINAMICS G120 remains connected to the line supply and its full diagnostics capability is retained.
2xDI as F-DI
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 8 2012-03-08
SS1 (Safe Stop 1) using conventional wiring
While the drive is stopped using OFF3 motion is not monitored. -> If a fault condition develops the drive can accelerate and is only shut down after the time delay has expired (typ. 3s).
High wiring costs as a result of the safety relay and contactors. It is easy to change the value of the time delay without any specific authorization.
After pressing the Emergency Stop pushbutton a fast stop is activated in the converter via OFF 3 and the drive then brakes.
The contactor safety combination opens the two line contactors K1 and K2 after a time delay (typ. 3s) (controlled stopping with a safely monitored deceleration time).
Converter
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 9 2012-03-08
SS1 (Safe Stop 1) using the safety digital inputs of the SINAMICS G120
While the drive is stopping, motion is continually monitored. If the drive does not follow/track the parameterized ramp then STO is immediately initiated.
Speed feedback is not required using an encoder for the safety function. Cost saving as a result of minimized wiring costs and space saving as the Emergency Stop pushbutton is directly
connected to the SINAMICS G120 via the safety digital inputs without safety contactor combination. Risks are minimized for the plant construction company by using password-protected safety parameters in G120.
After pressing the Emergency Stop button the Safe Stop 1 safety function in the SINAMICS G120 is activated and the drive is decelerated using the safety ramp function. At zero speed (from 2 Hz and below) STO is activated (controlled stopping with safely monitored braking ramp). Caution ! The motor is not electrically isolated from the line supply.
2xDI as F-DI
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 10 2012-03-08
SLS (Safely Limited Speed) using conventional wiring
Extremely high wiring costs as a result of several safety relays and contactors. A speed encoder, two initiators and a safety-relevant speed monitor are required to sense the speed.
There is no protection against the safety functions being manipulated. Intensive maintenance & service required as there are many independent monitoring devices and mechanical shutdown.
The converter is shut down if the speed is exceeded.
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 11 2012-03-08
SLS (Safely Limited Speed) using the safety digital inputs of the SINAMICS G120
After SLS is activated - depending on the parameterized mode - the drive is decelerated to the parameterized SLS (Safety Limited Speed) or, if the speed is exceeded, STO is activated. In addition, there is still a second safety function available – such as STO or SS1. Caution! It is not possible to accelerate to the SLS (Safely Limited Speed) from standstill (zero speed).
Neither external monitoring devices nor speed encoder required as the safety function is integrated in SINAMICS G120 without any encoder (sensorless).
When SLS is activated, the deceleration ramp is immediately monitored and the speed limited. STO is immediately initiated if the drive does not follow/track the parameterized ramp or the parameterized SLS speed is exceeded.
Cost saving through minimum wiring costs and space saving as the safety sensors (Emergency Stop pushbutton, light curtains etc.) are directly connected to G120 via the safety digital inputs without requiring a safety contactor combination.
Risks are minimized for the plant construction company by using password-protected safety parameters in the G120.
2xDI as F-DI each
© Siemens AG 2012. All Rights Reserved.
SINAMICS G120C
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 13 2012-03-08
SINAMICS G120C Technical data overview
Voltage 3~380 – 480 V
Power 0.55 – 18.5 kW
Degree of protection IP20 / UL / cUL open type
Control types V/F, SLVC
Safety Safe Torque Off (STO)
TIA Yes, STARTER, DriveES SIMATIC
Communication PROFINET, PROFIBUS, USS, Modbus RTU, CAN (PN planned for FY 12)
Braking possibilities Braking resistor, compound brake, DC brake
I/Os 6 DI, 2 DO, 1 AI, 1 AO
Filter Unfiltered or filter A integrated
Certificates CE, UL, ctick
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 14 2012-03-08
SINAMICS G120C Control Unit
Software Closed-loop control functions:
Vector control (speed control, no torque control) V/f (linear, quadratic, FCC, ECO)
Safety functions Safe torque off (STO, SIL2, PLd, PFHD = 5.00 10-8)
PROFIsafe (with PROFINET or PROFIBUS)
SW functions derived from SINAMICS pool SW 4.4: Write protection and know-how protection
Data record switching between two data records Dynamic change of the ramp times during operation
640 parameters (level 1-4) Application macro parameter P0015
Energy-saving counter 1 PID for process control
Flying restart + automatic restart 1 DriveDataSet (DDS)
2 CommandDataSet (CDS) No free function blocks No torque monitoring
No droop
© Siemens AG 2012. All Rights Reserved.
CU240D-2 and CU250D-2
SINAMICS G120D - Next Generation
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 16 2012-03-08
Control Units CU 240D …
Power Module PM 250D 0.75 kW up to 7.5 kW 3 frame sizes with identical footprint
SINAMICS G120D - The highest innovated decentralized drive
CU 240D-2 PROFIBUS
CU 240D-2 PROFINET
CU 240D-2 PROFIBUS CU 250D-2
PROFINET
Safety Integrated
CU 240D-2 PROFINET
CU 250D-2 PROFIBUS
…
Positioning (EPos)
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 17 2012-03-08
CU240D-2 and CU250D-2 (EPos) - With new features
PROFIBUS-ADRESS switch + USB interface for commissioning (STARTER)
MMC / SD slot
24V supply IN/OUT
Field bus IN/OUT
2x DO or 1x F-DO
HTL encoder interface
6x DI or up to 3x F-DI
Status LED optical interface for
commissioning (IOP)
CU240D-2: 2x analog- or digital-inputs CU250D-2: 1x SSI encoder interface
Der erste PROFIenergy fähige SINAMICS mit Modi
No encoder
Worldwide unique
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 18 2012-03-08
CU240D-2 and CU250D-2 (EPos) - Push Pull variant with new features
MMC / SD slot
optical interface for commissioning
(IOP)
24V supply IN/OUT
Field bus IN/OUT
2x DO or 1x F-DO
HTL encoder interface
6x DI or up to 3x F-DI
Status LED
CU240D-2: 2x analog- or digital-inputs CU250D-2: 1x SSI encoder interface
The USB commissioning interface is not available
Der erste PROFIenergy fähige SINAMICS mit Modi
No encoder
Worldwide unique
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 19 2012-03-08
SINAMICS G120D - Safety overview
Integrated Safety Functions
Standard CU´s: STO (Safe Torque Off) Failsafe CU´s (-F):
STO (Safe Torque Off) SS1 (Safe Stop 1) SLS (Safely Limited Speed) 4 values with PROFIsafe SSM (Safe Speed Monitor) SDI (Safe Direction)
General Every power unit is prepared for Safety Integrated Only the Control Unit used is decisive There is no encoder necessary for the safety functions
Control of the safety functions
Via failsafe digital inputs (Standard CU´s: 1 F-DI, failsafe CU´s (-F): up to 3 F-DI)
Via PROFIsafe Combination of F-DI and PROFIsafe (only STO)
Feedback of the safety functions
Via failsafe digital output (only failsafe CU´s (-F)) Via PROFIsafe Feedback of the F-DI status via PROFIsafe (only failsafe CU (-F))
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 27 2012-03-08
Přehled bezpečnostních funkcí v pohonech SINAMICS
SINAMICS S120 Chassis & Cabinet
SINAMICS G120 F-Version 240E-2F
SINAMICS G120/C/D 240E-2,2x0D-2
SINAMICS S120
ET200 S/PRO FC F-Version
SINAMICS G120D F-Version 240D-F
Drive
STO SS1 SBC SLS SS2 SOS SSM
STO SS1
STO SS1
STO SS1
STO
SLS
SLS
Basic Functions / Extended Functions
SLS SDI SSM
SINAMICS S110 SDI
STO SS1 SBC SLS SS2 SOS SSM SDI
SINAMICS S150
SINAMICS G130/150
STO SS1
STO SS1
STO SS1
SLS SS2 SOS SSM SDI
SLS SS2 SOS SSM SDI
SLP
SLP
SLP
SBC
SBC
SINAMICS G120 250S-2 SLS SSM SDI STO SS1 SBC SS2 SOS
SINAMICS G120D F-Versions CU 240D-2F / CU 250D-2F
STO SS1 SLS SDI SSM
SBC
In preparation
In preparation
= encoderless possible
= part of the product
= activated by license
= sin/cos encoder required
© Siemens AG 2012. All Rights Reserved. Industry Sector Page 28 2012-03-08
Radek Novotný
Tel: 544 508 467
Email: [email protected]
Siemens s.r.o.
Olomoucká 7/9
618 00 Brno
www.siemens.com/safety-integrated
www.siemens.cz/safety
safety_integrated_4-3_(new_picture).ppt
Děkuji za Vaši pozornost!