SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&D PT1 M/05.04.00/N° 1 WinCC_V5_xie8.ppt/Sch.

  • Published on
    23-Dec-2015

  • View
    219

  • Download
    0

Transcript

<ul><li> Slide 1 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 1 WinCC_V5_xie8.ppt/Sch SIMATIC WinCC V5.0 WinCC V5 Under Windows NT </li> <li> Slide 2 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 2 WinCC_V5_xie8.ppt/Sch Highlights of the Version MultiServer Web Navigator Totally Integrated Automation Efficient Configuration Functional Enhancements in the Graphics Designer Enhancements to Communications Enhancements in WinCC V5 Service Pack 1 SIMATIC WinCC V5.0 </li> <li> Slide 3 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 3 WinCC_V5_xie8.ppt/Sch Multi Server Overview Distribution of Servers Higher Performance Profile Easier Expansion of the System Better Performance Multi Client as a Common View of the Servers WinCC - scaleable from a single-user station up to a distributed system. </li> <li> Slide 4 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 4 WinCC_V5_xie8.ppt/Sch Distribution of Servers Overview Performance Profile 6 servers (redundant pairs too) with up to 16 clients ( tested performance profile) Distribution is Solved by Configuration Functional distribution, e.g. for archiving and visualization Distribution to subsystems </li> <li> Slide 5 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 5 WinCC_V5_xie8.ppt/Sch Distribution of Servers Functional Distribution Alarm Server Visualization Server Trend Server Multi Client </li> <li> Slide 6 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 6 WinCC_V5_xie8.ppt/Sch Distribution of Servers Distribution to Subsystems Plant Section 2Plant Section 3Plant Section 1 Multi Client </li> <li> Slide 7 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 7 WinCC_V5_xie8.ppt/Sch Distribution of Servers Configuration of Distributed Systems WinCC ServerWinCC Multi Client 1. Transfer/Conversion of Version 4 Projects and Pictures 2. Independent Configuration of the Servers (in accordance with Version 4.x) 3. Generation of Server Data The server package contains a list of picture names, variables and archives of the server that a Multi Client needs for its configuration. 4. Configuration of the Multi Client Project </li> <li> Slide 8 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 8 WinCC_V5_xie8.ppt/Sch Multi Client Overview The Multi Client takes an important part in a distributed system A Multi Client provides a common view of the process data of distributed servers in one picture all the measured value archives, e.g. in one curve window all the message archives the pictures/picture windows of different servers Integration and bringing together of different server projects at the Multi Client </li> <li> Slide 9 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 9 WinCC_V5_xie8.ppt/Sch Multi Client Configuration of the Multi Client The Multi Client has its own project The server data is loaded on the Multi Client The view of the different servers is based on a new property: the server prefix ServerName::TagName The system automatically transfers the server prefix to scripts, controls, pictures on the Multi Client </li> <li> Slide 10 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 10 WinCC_V5_xie8.ppt/Sch Multi Client Overview of Distributed System WinCC Server2 WinCC Multi Client WinCC Server1 Standard Client The Multi Client has its own project including additional pictures, e.g. for a common plant-wide alarm view. </li> <li> Slide 11 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 11 WinCC_V5_xie8.ppt/Sch Multi Client View of Tags of Different Servers I/O field linked to Server1::Tag1 I/O field linked to Server2::Tag2 WinCC Server2 WinCC Multi Client WinCC Server1 </li> <li> Slide 12 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 12 WinCC_V5_xie8.ppt/Sch Multi Client - View of Process Value Archives of Different Servers Server1::Tag1 Server2::Tag2 </li> <li> Slide 13 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 13 WinCC_V5_xie8.ppt/Sch Multi Client - View of Message Archives of Different Servers </li> <li> Slide 14 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 14 WinCC_V5_xie8.ppt/Sch Multi Client - View of Picture Windows of Different Servers WinCC Server2 WinCC Multi Client WinCC Server1 Server1::Server2:: </li> <li> Slide 15 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 15 WinCC_V5_xie8.ppt/Sch Serv 1 Overview Picture Multi Client View of Pictures of Different Servers Server2 Server1 Serv 2 Overview Picture WinCC Multi Client Multi Client Overview Picture Server1Server2 Server Picture </li> <li> Slide 16 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 16 WinCC_V5_xie8.ppt/Sch Web Navigator Overview Web Navigator Server Communication to the WinCC Server Administration of Access Rights Web Navigator Client Operation and Monitoring Over the Web Limited operator inputs or purely view only function depending on the access rights Minimum installation including WinCC ActiveX controls via network too WinCC Goes Web Operation and monitoring of the plant via the Worldwide Web </li> <li> Slide 17 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 17 WinCC_V5_xie8.ppt/Sch Web Navigator Plant Configuration I HTTP Request HTTP Result Firewall Browser Web ClientWeb Server WinCC Data Source Web Server Client-PC </li> <li> Slide 18 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 18 WinCC_V5_xie8.ppt/Sch Web Navigator Plant Configuration II Browser HTTP Request Web ClientWeb Server WinCC Web Server WinCC Data Source HTTP Result Firewall e.g. OPC Client PC </li> <li> Slide 19 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 19 WinCC_V5_xie8.ppt/Sch Web Navigator Plant Configuration III Browser Http Request Web ClientWeb Server WinCC Web Server WinCC DataSource Http Result Firewall Client PC Maximum safety by physical separation of plant network and Internet </li> <li> Slide 20 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 20 WinCC_V5_xie8.ppt/Sch Web Navigator Client Strengths Plant visualization and operation across the Interne / Intranet Web Navigator Client is a thin client (up to 50 clients) View of the plant or manufacturing information for Managers Direct plant control by remote diagnostics for example Safety by several levels of security User-specific password Firewall technology Support of encoded communication Minimal installation at client side (no entire WinCC system) Direct use of WinCC pictures for the web Optimized communications and performance Optimization of WinCC pictures Pictures can be transferred directly </li> <li> Slide 21 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 21 WinCC_V5_xie8.ppt/Sch Web Navigator Client Limitations of the Web Client When transferring the comprehensive WinCC Runtime functionality to the minimum web client execution environment, there are some limitations: No logs (log output on the web client is not supported) No online configuration of server projects No user archives No global scripts Project and global functions must be present on the local system: this is of course not possible with a Web client. As a result, these functions are not executed on the Web client. The system does support event-triggered scripts (e.g. on mouse click) in pictures and on objects. Referenced graphics (e.g. bitmaps) on buttons, graphic objects etc. are not displayed No full PCS7 support, e.g. navigation through pictures </li> <li> Slide 22 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 22 WinCC_V5_xie8.ppt/Sch Totally Integrated Automation Overview Direct Use of STEP 7 Symbols in WinCC STEP 7 Block Call from WinCC Runtime Entry into STEP 7 Hardware Diagnostics </li> <li> Slide 23 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 23 WinCC_V5_xie8.ppt/Sch Totally Integrated Automation Interconnection of STEP7 Symbols WinCC Project as a Part of the STEP 7 Project Interconnection of STEP 7 Symbols from the WinCC Tag Dialog WinCC tag dialog box of the Graphics Designer with view of the STEP 7 data store. No duplicate input of tags. Direct access to STEP 7 data. Addressing errors avoided due to consistency </li> <li> Slide 24 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 24 WinCC_V5_xie8.ppt/Sch Totally Integrated Automation STEP 7 Block Call STEP 7 Block Call from WinCC Runtime Representation of active networks Return to the corresponding WinCC picture Navigation to different places of use Jump to a defined STEP 7 network from a WinCC picture in runtime for diagnostic purposes. Rapid, guided diagnostics in the STEP 7 program. </li> <li> Slide 25 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 25 WinCC_V5_xie8.ppt/Sch Totally Integrated Automation STEP7 Block Call Overview Network Entry Return to the WinCC Picture Symbol Table Symbol Places of Use FB1 Network x FB2 Network y S7 Network (Automatic) </li> <li> Slide 26 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 26 WinCC_V5_xie8.ppt/Sch Totally Integrated Automation Entry into STEP 7 Hardware Diagnostics Start of the STEP 7 function hardware diagnosis from WinCC Runtime Hardware error detection in WinCC e.g. via a message HW error </li> <li> Slide 27 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 27 WinCC_V5_xie8.ppt/Sch Efficient Configuration Overview Cross-Reference List Listing in table form of tags, pictures, functions... Selective lists Central rewiring Jump from the cross-reference list to the tags' place of use Display of all the dynamic properties of a picture Dragging and dropping of tags Rapid rewiring of tags in pictures </li> <li> Slide 28 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 28 WinCC_V5_xie8.ppt/Sch Efficient Configuration Cross-Reference List Listing in table form of tags, pictures, functions... Direct rewiring or jump to place of use Subdivided by variables in use or not in use </li> <li> Slide 29 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 29 WinCC_V5_xie8.ppt/Sch Efficient Configuration Cross-Reference List Selective lists in accordance with the filter setting Selection by objects, e.g. pictures as in use or not in use Search in pictures, functions, archives, messages </li> <li> Slide 30 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 30 WinCC_V5_xie8.ppt/Sch Efficient Configuration Picture Properties Picture preview Display of picture dynamization in an overview or selectively by type of dynamization </li> <li> Slide 31 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 31 WinCC_V5_xie8.ppt/Sch Efficient Configuration Dragging &amp; Dropping Tags Tag linking in the Graphics Designer by means of drag &amp; drop Rapid rewiring of variables in pictures </li> <li> Slide 32 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 32 WinCC_V5_xie8.ppt/Sch Functional Enhancements (Graphics Designer) User Interface Tag and ActiveX Toolbar Multiline Button Labels </li> <li> Slide 33 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 33 WinCC_V5_xie8.ppt/Sch Functional Enhancements (Graphics Designer) Trend/Alarm Windows as ActiveX Controls Conversion of Application Window to ActiveX Controls Direct display and configuration of message and trend windows after pasting the controls in the Graphics Designer Storage of sample controls in the library New Functions of the Controls Online trend window without its own archive Free definition of number of places after decimal point in Table Control Quick configuration dialog Direct display of trend and alarm windows in Graphics Designer </li> <li> Slide 34 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 34 WinCC_V5_xie8.ppt/Sch Functional Enhancements (Graphics Designer) Display of DXF Data Display of DXF Data (E-Plan, AutoCAD) Output via an ActiveX control Zoom function in the view Wizard support Central or local data storage possible of DXF files View of the plant data for trouble-shooting, for example, right down to the wiring dia- gram from WinCC Runtime. </li> <li> Slide 35 </li> <li> SIMATIC HMI - Human Machine Interface WinCC Version 5 SIMATIC HMI - Human Machine Interface WinCC Version 5 A&amp;D PT1 M/05.04.00/N 35 WinCC_V5_xie8.ppt/Sch...</li></ul>

Recommended

View more >