79
Code Consultants, Inc. Significant Changes to the ICC/A117.1-2017 Changes Part - 2 1

Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Code Consultants, Inc.

Significant Changes to the ICC/A117.1-2017 ChangesPart - 2

1

Page 2: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Objectives

• Overview of the changes to the Technical Requirements

2

Part 1:ANSI BackgroundChapters 3-4

Part 2:Chapters 5, 6, 7, 8, & 9

Page 3: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Chapter 5 – General Site and Building Elements

3

Page 4: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

General Site and Building Elements

• Parking• Meters• Electrical Charging

Stations • Accessible Routes

through parking• Stairways

4

Page 5: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Parallel parking space

• Where the width of the adjacent sidewalk or available right-of-way exceed 14 feet, an access aisle 60 inches wide minimum must be provided at street level the full length of the parking space and must connect to a pedestrian access route.

• The access aisle must comply with Section 502.4 and must not encroach on vehicular travel lanes.

5

Page 6: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Parallel parking space• An accessible route is required from the vehicle level to the sidewalk.

6

Page 7: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Parallel parking space

• Alterations: In alterations where the street or sidewalk

adjacent to the parking spaces is not altered, an access aisle is not required provided the parking spaces are located at the end of the block face.

7

Page 8: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Parallel parking space

• Narrow sidewalks: An access aisle is not

required where the width of the adjacent sidewalk or the available right-of-way is less than or equal to 14 feet.

Where an access aisle is not provided, the parking spaces must be located at the end of the block face.

8

Page 9: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Perpendicular or Angled Parking Spaces

• Where perpendicular or angled parking is provided, an access aisle 96 inches wide minimum must be provided at street level the full length of the parking space and must connect to a pedestrian access route.

• The access aisle must comply with Section 502.4 and must be marked so as to discourage parking in the access aisle.

• Two parking spaces are permitted to share a common access aisle.

9

Page 10: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Parking meters and parking pay stations

• Location: At parallel parking spaces, parking meters must be located at the head or foot of the parking space.

• Displays and information must be visible from a point located 40 inches maximum above the center of the clear space in front of the parking meter or parking pay station.

10

Page 11: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Electrical vehicle charging stations

• Operable parts on the charging station intended for operation by the user, including card readers, must comply with Section 309.

• An accessible route must be provided from the access aisle adjacent to the parking space to clear floor space complying with Section 502.11.1 adjacent to the vehicle charging station. When the vehicle is being charged, the accessible route must not be obstructed by the cable between the car and charging station.

11

Page 12: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Electrical vehicle charging stations

• Protection bollards, curbs or wheel stops must be located so that they do not obstruct the clear floor space required by Section 502.11.1 or the accessible route required by Section 502.11.2.

• Specific sizes for the charging station are not specified. It can be sized for a van or a car.

• Scoping provisions are not provided in the IBC. Some states have specific criteria.

12

Page 13: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Electrical vehicle charging stations

13

Recommended width – not required. An accessible route is required (exterior = 48 inches).

Charging station cable must not obstruct accessible route.

Page 14: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Electrical vehicle charging stations

14

Page 15: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Passenger Loading - Access Aisle Width

• New buildings and facilities In new buildings and facilities, aisles serving vehicular pull-up

spaces must be 67 inches minimum in width. Access aisles must extend the full length of the vehicle pull-up

spaces they serve.

15

Page 16: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Passenger Loading - Access Aisle Width

• Existing buildings and facilities In existing buildings and facilities, access aisle serving vehicle

pull-up spaces must be 60 inches minimum in width. Access aisles must extend the full length of the vehicle pull-up

spaces they serve.

16

Page 17: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Stairways

• Stairways are not considered part of an accessible route so they do not have any scoping within the IBC.

• Stairways, although they can be part of an accessible means of egress are not scoped from the IBC. The IBC contains requirements within itself.

• Therefore, the following is “best practice” information. It is NOT required to be a part of the design.

17

Page 18: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Stairway Nosings

• If beveled, the bevel at the leading edge must slope at 45 degrees to the plane of the top surface of the tread and landing and extend for a horizontal distance of ½ inch maximum.

18

Page 19: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Stairway – Visual Contrast

Visual contrast must comply with either 1 or 2.1. The leading 1 to 2 inches of every tread and landing,

measured horizontally from the leading edge of the nosing, must consist of a solid color having visual contrast of dark-on-light or light-on-dark from the remainder of the tread. The contrasting marking must be durable and must extend from one side of each tread to the other side of each tread.

2. Durable distinctive warning markings required by the adopted building code of ANSI safety standards.

19

Page 20: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Tactile signage at stair exits

A sign stating “EXIT” in raised characters and Braille and complying with Sections 703.3 and 703.4 must be provided adjacent to each door to an area of refuge providing direct access to a stairway, an exterior area for assisted rescue, an exit stairway, an exit ramp, an exit passageway and exit discharge.

20

Presenter
Presentation Notes
This IS scoped within the building code
Page 21: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Accessible Routes through Parking

• Where accessible routes pass through parking facilities, they must be physically separated from vehicular traffic.Exceptions: Accessible routes crossings drive aisles may not be required to

comply with this section Accessible routes only from parking spaces complying with

Section 502 and passenger loading zones complying with Section 503 to accessible entrances may not be required to comply with this section.

21

Page 22: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Chapter 6 – Plumbing Elements

22

Page 23: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Plumbing Elements and Facilities

• Bottle filling stations• Single occupant toilet rooms• Multi-stall toilet rooms

23

Page 24: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Bottle Filling Stations

• A clear floor space positioned for a forward or side approach must be provided.

24

• Controls for bottle filling stations must be hand operated or automatic. Hand operated controls must comply with Section 309.

Page 25: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Bottle Filling Stations

• General Exception: Where bottle filling stations are part of the drinking fountain for persons who are standing, the bottle filling station is not required to comply with this section provided a bottle filling station is located at the drinking fountain for persons using wheelchairs.

25

OK, if…

Page 26: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Rear-Wall Grab Bars

• The fixed rear-wall grab bar must: Be 36 inches minimum

in length, Be located 6 inches

maximum from the side wall, and

Extend 42 inches minimum from the side wall.

26

Page 27: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Toilet Paper Dispenser - General

(Unchanged)• Where located below the

grab bar, toilet paper dispensers shall be located 24 inches minimum and 42 inches maximum from the rear wall.

• The outlet of the dispenser must be 18inches minimum and 48 inches maximum above the floor.

27

Presenter
Presentation Notes
Note that the outlet is addressed here not the dispenser as a whole.
Page 28: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Toilet Paper Dispenser - Exception

• Toilet paper dispensers that accommodate a maximum of 2 toilet paper rolls of not more than 5-inch diameter each is permitted to be located 7 inches minimum and 9 inches maximum in front of the water closet measured to the centerline of the dispenser.

• The outlet of the dispenser must be 15 inches minimum and 48 inches maximum above the floor.

28

Presenter
Presentation Notes
Note “outlet” is not used here – just the centerline of the dispenser.
Page 29: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Toilet Paper Dispenser - Exception

29

Presenter
Presentation Notes
Note “outlet” is not used here – just the centerline of the dispenser.
Page 30: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Wheelchair accessible toilet compartment

• Where an alternate wheelchair accessible toilet compartment is provided, the minimum area of the compartment must be 60 inches minimum in width, measured perpendicular to the side wall, and 84 inches minimum in depth, measured perpendicular to the rear wall.

• Not scoped…

30

Allows 52 inches in front of WC rim, with the front rim of the WC 36 inches from rear wall.

Page 31: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Doors - Exception

• In an alternate wheelchair accessible toilet compartment, the door is permitted to swing into the stall where a clear floor space complying with Section 305.3 is provided within the stall beyond the arc of the door swing.

31

Page 32: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Toe Clearance

• The front partition and at least one side partition of wheelchair accessible toilet compartment must provide a toe clearance of 12 inches minimum above the floor and extending 8 inches beyond the compartment side face of the partition, exclusive of partition support members.

32

Page 33: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Toe Clearance - Exceptions

• Toe clearance at the front partition is not required in a wheelchair accessible toilet compartment greater than 64 inches in depth with a wall-hung water closet, or greater than 67 inches in depth with a floor-mounted water closet.

• Toe clearance at the side partition is not required in a wheelchair accessible toilet compartment greater than 68 inches in width.

33

Page 34: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Toe Clearance – Children’s use

• The front partition and at least one side partition of wheelchair accessible toilet compartment primarily for children’s use must provide a toe clearance of 12 inches minimum above the floor and extending 8 inches beyond the wheelchair accessible toilet compartment side face of the partition, exclusive of partition support members.

34

Page 35: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Toe Clearance Exception – Children’s use

• Toe clearance at the front partition is not required in a wheelchair accessible toilet compartment greater than 67 inches in depth.

• Toe clearance at the side partition is not required in a wheelchair accessible toilet compartment greater than 68 inches in width.

35

Page 36: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Ambulatory Accessible Toilet Compartment

• Size The minimum area of

an ambulatory of an ambulatory accessible toilet compartment must be 60 inches minimum in depth and a width of 35 inches minimum and 37 inches maximum.

36

Page 37: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Urinals – Stall Type

• Depth Urinals must be 13-1/2

inches minimum in depth measured from the outer face of the urinal rim to the finished wall surface.

37

Page 38: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Lavatories with enhanced reach range

• New Exceptions: Enhanced reach range faucets are not required

on lavatories provided with automatic faucets where the reach depth to activate the faucets and the reach depth to water outlet is 11 inches minimum.

Enhanced reach range soap dispensers are not required on lavatories provided with automatic dispensers where the reach depth to activate the soap dispensers and the reach depth to the soap outlet is 11 inches maximum.

38

Page 39: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Chapter 7 – Communication Elements

39

Page 40: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Communication Elements and Features

• Sign contrast• Detectable Warning Surfaces

40

Page 41: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Signs - Contrast

• Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background, or dark characters on a light background.

• The glare from coverings and the finish of pictograms and their fields shall not exceed 19 gloss units (gu) as measured on a 60-degree gloss meter.

41

Page 42: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Signs - Contrast

42

Page 43: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Detectable Warning Surfaces

• Where required 1. Curb ramps and blended transitions at

pedestrian street crossings; 2. Pedestrian refuge islandsException: Detectable warning surfaces shall not be required at pedestrian refuge islands that are cut-through at street level and are less than 6 feet in length in the direction of pedestrian travel.

43

Page 44: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Detectable Warning Surfaces

• Where required 3. Pedestrian at-grade rail crossings not located

within a street or highway; 4. Boarding platforms at transit stops for buses and

rail vehicles where the edges of the boarding platform are not protected by screens or guards; and,

5. Boarding and alighting areas at sidewalk or street level transit stops for rail vehicles where the side of the boarding and alighting areas facing the rail vehicles is not protected by screens or guards.

44

Page 45: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Detectable Warning Surfaces

• Depth and Width Detectable warning surface must extend 24

inches minimum in the direction of pedestrian travel.

At curb ramps and blended transitions, detectable warning surfaces must extend the full width of the curb ramp run excluding any flared sides or blended transition.

45

Page 46: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Detectable Warning Surfaces

• Depth and Width

46

Page 47: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Detectable Warning Placement

• Perpendicular Curb RampsOn perpendicular curb ramps, detectable warning surfaces must be placed as follows:• Where the ends of the bottom grade break are in front of the back of

curb, detectable warning surfaces must be placed at the back of curb.• Where the ends of the bottom grade break are behind the back of curb

and the distance from either end of the bottom grade brake to the back of curb is 60 inches or less, detectable warning surfaces must be placed on the ramp run within one dome spacing of the bottom grade break.

• Where the ends of the bottom grade break are behind the back of curb and the distance from either end of the bottom grade brake to the back of curb is more than 60 inches, detectable warning surfaces must be placed on the lower landing at the back of curb.

47

Page 48: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Detectable Warning Placement

Perpendicular Curb Ramps

48

Page 49: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Detectable Warning Placement

• Parallel Curb RampsOn parallel curb ramps, detectable warning surfaces must be placed on the turning space at the flush transition between the street and side-walk.

49

Page 50: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Detectable Warning Placement

• Blended TransitionsOn blended transitions, detectable warning surfaces must be placed at the back of curb. Where raised pedestrian street crossings, depressed corners or other level pedestrian street crossings are provided, detectable warning surfaces must be placed at the flush transition between the street and the sidewalk.

50

Page 51: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Detectable Warning Placement

• Pedestrian Refuge Islands

At cut-through pedestrian refuge islands, detectable warning surfaces must be placed at the edges of the pedestrian island and must be separated by 24 inches minimum length of surface without detectable warnings.

51

Page 52: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Chapter 8 – Special Occupancies

52

Page 53: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Special Rooms and Spaces

• Assembly seating• Sign Language interpreter station• Charging Stations

53

Page 54: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Assembly Area Wheelchair spaces - Depth

Where a wheelchair space is entered from the front or rear, the wheelchair space must be 52 inches minimum in depth.

Where a wheelchair space is entered from the front or rear, the wheelchair space must be 48 inches minimum in depth.

New Existing

54

Page 55: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Assembly Area Wheelchair Spaces- Depth

• In New and Existing buildings, where a wheelchair space is only entered from the side, the wheelchair space must be 60 inches minimum in depth.

55

Page 56: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Assembly Area Wheelchair Spaces- Depth

• Side Approach

56

Page 57: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Assembly Area Wheelchair Spaces- Depth

• Rear Approach

57

Page 58: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Companion Seat Alignment

• The shoulder of the wheelchair space occupant is considered to be 36 inches or more from the front and 12 inches or more from the rear of the wheelchair space.

58

Page 59: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Companion Seat Alignment

• Existing and New - Side approach

• Existing Front or rear approach

• New Front or rear approach

59

Page 60: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Charging Stations

• Where charging stations are provided at wheelchair space locations, they must comply with Section 906.

• Section 906 A charging stations

must consist of a ground duplex outlet

A clear floor space must be provided at the charging station

Charging stations must comply with at least one of the reach ranges specified in Section 308.

60

Page 61: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Charging Stations

61

Page 62: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Spaces utilized primarily for viewing motion picture projections

• Not new requirements – just coordinating with the ADA language.

• Spaces with seating on risers Where tiered seating is provided, wheelchair

space locations must be integrated into the tiered seating area on a riser or a cross-aisle.

62

Page 63: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Spaces utilized primarily for viewing motion picture projections

• Distance from the screen Wheelchair space locations must be located in

accordance with one of the following:○ Within the rear 60 percent of the seats provided;

or○ Located within the area of an auditorium in which

the vertical viewing angles, as measured to the top of the scree, are from the 40th to the 100th

percentile of vertical viewing angles for all seats ranked from the seats in the first row to seats in the back row.

63

Page 64: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Sign language interpreter stations

• Because some theaters have live performances as well... Regardless, there’s no scoping for this yet.

• Area A sign language interpreter station must provide

a level and clear floor of a minimum size of 24 inches deep and 36 inches wide that is located to provide a direct line of sight from the seating area identified in Section 802.11.3

64

Page 65: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Sign language interpreter stations

• Location Sign language interpreter stations must be

located so that seating within an arc from the station and measured to the left and to the right 60 degrees within 65 feet horizontal distance from the station is provided with sight lines providing a view of the sign language station from a height of 36 inches to 72 inches above the floor of the station.

65

Page 66: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Sign language interpreter stations

• Illumination The sign language interpreter station must have

lighting facilities capable of providing 10 footcandles of illuminance while signing is underway measured at the center of the floor of the sign language station at a height of 48 inches above the floor.

66

Page 67: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Sign language interpreter stations

• Backdrop Where a sign language interpreter station is located

with a permanent wall less than 10 feet behind the sign language interpreter station, the permanent wall to a height of 96 inches from the finish floor must be considered as a backdrop. The backdrop must provide a flat, smooth surface with a monochromatic, low-luster finish treatment.

Exception: The wall may not be required to comply with this section where a backdrop with a monochromatic, low luster finish treatment is provided.

67

Page 68: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Chapter 9 - Furnishings

68

Page 69: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Furnishings and Equipment

• Sales and Service Counters and Windows• Gaming Machines and Tables

69

Page 70: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Sales and service counters and windows

• Where counters are provided, the accessible portion of the counter-top must extend the same depth as the public portion of the sales and service countertop provided for standing customers.

Exception: In alterations, when the provision of a counter complying with this section would result in a reduction of the number of existing counters at work stations or a reduction of the number of existing mail boxes, the counter may be permitted to have a portion which is 24 inches minimum in length complying with Section 904.3.2 provided that the required clear floor space is centered on the accessible length of the counter.

70

Page 71: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Sales and service counters and windows

• Cross Section • Elevation

71

Page 72: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Sales and service counters and windows

• Vertical barriers At service windows or service counter, any vertical

barrier between service personnel and customers must be at a height of 43 inches maximum above the floor.

Exception: Transparent security glazing may be permitted above the 43 inches maximum height.

72

Page 73: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Sales and service counters and windows

• Vertical barriers

73

Page 74: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Sales and service counters and windows

• Parallel approach A portion of the public use side of the counter surface 36

inches minimum in length and 26 inches minimum to 36 inches maximum in height above the floor must be provided.

A clear floor space positioned for a parallel approach adjacent to the accessible counter must be provided.

The space between the accessible counter surface and any projecting objects above the accessible counter must be 12 inches minimum.

Exception: Where the counter surface is less than 36 inches in length, the entire counter surface must be 26 inches minimum to 36 inches maximum in height above the floor.

74

Page 75: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Sales and service counters and windows

• Forward approach A portion of the public use side of the counter surface 30

inches minimum in length and 36 inches maximum in height above the floor must be provided.

A clear floor space positioned for a forward approach to the accessible counter must be provided.

Knee and toe clearance complying with Section 306 must be provided under the accessible counter (17-25 inches).

The space between the accessible counter surface and any projection object above the accessible counter must be 12 inches minimum.

75

Page 76: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Sales and service counters and windows

76

Page 77: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Gaming Machines and Table

• Gaming machines and tables must have a clear floor space positioned for transfer or for use by an individual seated in a wheelchair.

• Clear floor spaces required at gaming machines and table are permitted to overlap.

77

Page 78: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

Questions?

78

Page 79: Significant Changes to the ICC/A117.1-2017 Changes Part - 2 · Stairways • Stairways are not considered part of an accessible route so they do not have any scoping within the IBC

79

Code Consultants, Inc.2043 Woodland Pkwy; Suite 300

St. Louis, Missouri 63146314-991-2633

Code Consultants, Inc.455 S. Figueroa St Suite 3100Los Angeles, California 90071

213-622-5880

Code Consultants Professional Engineers, PC215 West 40th Street, 10th Floor

New York, New York 10018212-216-9596

© 2017 CODE CONSULTANTS, INC.