Upload
jitendra-nayak
View
241
Download
6
Embed Size (px)
DESCRIPTION
Signal Light Column Interface Unit Manual Tms
Citation preview
SIGNAL LIGHT COLUMN
INFTERFACE UNIT
USER MANUAL
< INTERFACE UNIT >
* Mode Select
5. Set Default
* Mode Select
1. Simulate Alarm
* Mode Select
2. Set Priority
* Mode Select
3. Set Alarm Time
* Mode Select
4. Set Sound Kind
< INTERFACE UNIT DISPLAY >
* MODE SELECT
1) Push MODE button
2) Push dirction button(Left/Right)
3) MODE will be changing in order as below
4) Select MODE type you want and push SET button so that you can use the
MODE type or you can change setting by pushing SET button.
5) If you push MODE button one more, LCD screen will be off
* Mode Select
1. Simulate Alarm
> Simulate Alarm
1. GENERAL EM'CY
> Simulate Alarm
8. TELEPHONE CALL
> Simulate Alarm
2. FIRE EM'CY
> Simulate Alarm
3. CO2 RELEASE
> Simulate Alarm
4. WATER FOG
> Simulate Alarm
5. MACHINERY
> Simulate Alarm
6. DEAD MAN
> Simulate Alarm
7. TELEGRAPH
1. Simulate Alarm
- Regardless of outside alarm signal, it virtually transmit alarm signal to each
SIGNAL LIGHT COLUMN. In this case, each SIGNAL LIGHT COLUMN is
operating as if real alarm happened.
1) Push MODE button.
2) Push SET button.
3) If you push direction button, the type of alarm you want to test will be
changing in order
* Mode Select
1. Simulate Alarm
* Mode Select
2. Set Priority
> Set Priority
1. GENERAL EM'CY
>> GENERAL EM'CY
CANCEL : SET Key
> Simulate Alarm
1. GENERAL EM'CY
4) Select Alarm button you want to test and push SET button one more.
If you selected GENERAL EM'CY, GENERAL EM'CY signal will be transmitted
to each COLUMN and each COLUMN sounds warning alarm.
5) Push SET button one more then alarm will be off
6) If you push MODE button one more, it will return to MODE SELECTOR
screen and if you push the button one more LCD screen will be off
2. Set Priority
You can set priority for preference alarm
1) Push MODE button.
2) Push direction button(Right).
3) Push SET button.
> Set Priority
8. TELEPHONE CALL
> Set Priority
2. FIRE ALARM
> Set Priority
3. CO2 RELEASE
> Set Priority
4. WATER FOG
> Set Priority
5. MACHINERY
> Set Priority
6. DEAD MAN
> Set Priority
7. TELEGRAPH
>>GENERAL EM'CY
<- 1 ->
>>GENERAL EM'CY
<- 2 ->
4) If you push direction button, the type of alarm you want to change priority
will be changing in order
5) Select the alarm you want to change and push SET button one more.
If you selected GENERAL EM'CY, GENERAL EM'CY will be your priority and
it will show on the screen
6) Push direction button.
Your priority alarm mode will be changed from 1 to 8
> Set Priority
1. GENERAL EM'CY
* Mode Select
1. Simulate Alarm
* Mode Select
3. Set Alarm Time
> Set Alarm Time
1. GENERAL EM'CY
> Set Alarm Time
2. FIRE ALARM
7) Select preference Priority and push SET button
The changed mode will be saved and it will return to setting screen of
preference priority
8) If you push MODE button, it will return to MODE SELECTOR screen and if
you push one more LCD screen will be off
3. Set Alarm Time
- You can set delaying time for each alarm
- ON TIME DELAY : If setting time has passed after setting of alarm, alarm
sounds in COLUMN
- OFF TIME DELAY : When alarm was set and cleared, if setting time has
passed the alarm will be cleared in COLUMN.
1) Push MODE button.
2) Push direction button(Right) twice.
3) Push SET button.
4) If you push direction button, the type of alarm which is going to set delaying
time will be changing in order.
> Set Alarm Time
8. TELEPHONE CALL
> Set Alarm Time
3. CO2 RELEASE
> Set Alarm Time
4. WATER FOG
> Set Alarm Time
5. MACHINERY
> Set Alarm Time
6. DEAD MAN
> Set Alarm Time
7. TELEGRAPH
>>GENERAL EM'CY
->ON:00 OFF:00
>>GENERAL EM'CY
->ON:99 OFF:00
>>GENERAL EM'CY
ON:99 ->OFF:00
5) Select alarm you want to set and push SET button one more.
If you selected GENERAL EM'CY, the current setting states of delaying time
will show up. Initial state is set to 0 second.
6) You can set time by pushing direction button and it can be set max.
99seconds.
7) After setting of ON TIME DELAY, if you push SET button the setting value
will be saved and cursor will move to OFF TIME DELAY mode
8) After setting of OFF TIME DELAY, if you push SET button the setting value
will be saved and cursor will move to OFF TIME DELAY.
>>GENERAL EM'CY
->ON:99 OFF:05
> Set Alarm Time
1. GENERAL EM'CY
* Mode Select
1. Simulate Alarm
* Mode Select
4. Set Sound Kind
> Set Sound Kind
1. GENERAL EM'CY
9) Push MODE button.
It will move to delaying time's setting mode
10) If you push MODE button, it will return to MODE SELECTOR screen and if
you push one more LCD screen will be off
4. Set Sound Kind
- You can select the type of warning sound for each alarm
1) Push MODE button.
2) Push direction button(Right) three times.
3) Push SET button.
4) If you push direction button, the type of alarm you want to change sound will
be changing in order.
> Set Sound Kind
8. TELEPHONE CALL
> Set Sound Kind
2. FIRE ALARM
> Set Sound Kind
3. CO2 RELEASE
> Set Sound Kind
4. WATER FOG
> Set Sound Kind
5. MACHINERY
> Set Sound Kind
6. DEAD MAN
> Set Sound Kind
7. TELEGRAPH
>>GENERAL EM'CY
<- 9 ->
>>GENERAL EM'CY
<- 1 ->
5) Select alarm you want to change and push SET button one more.
If you selected GENERAL EM'CY, the setting mode of current GENERAL
EM'CY sound will show up.
6) You can change the type of sound by pushing direction button and it can be
set 57 of different sound.
7) If you push SET button after sound setting, the setting value will be saved
and it will move to sound setting screen.
> Set Sound Kind
1. GENERAL EM'CY
* Mode Select
1. Simulate Alarm
* Mode Select
5. Set Default
> Are you sure?
Set:Yes, Mode:No
* Mode Select
5. Set Default
10) If you push MODE button it will return to MODE SELECTOR screen and if
you push button one more LCD screen will be off
5. Set Default
All setting value will return to initial status(Default)
.
1) Push MODE button.
2) Push direction button(Right) 4times.
3) Push SET button.
4) If you push SET button, it will be default and LCD Display will be off.
5) If you push MODE button, it will be out to Set Default.
6) If you push MODE button, it will return to MODE SELECTOR screen and LCD
screen will be off if you push one more.
Signal Light Column Sound Table
NO. Frequency Timbre NO. Frequency Timbre NO. Frequency Timbre
1 Continuous at 300Hz 21 200Hz Pulsing at 0.5Hz 41 500Hz Sawtooth at 0.5Hz
2 Continuous at 450Hz 22 200Hz Pulsing at 1Hz 42 500Hz Sawtooth at 1Hz
3 Continuous at 600Hz 23 200Hz Pulsing at 2Hz 43 500Hz Sawtooth at 2Hz
4 Continuous at 750Hz 24 700Hz Pulsing at 0.5Hz 44 900Hz Sawtooth at 0.5Hz
5 Continuous at 900Hz 25 700Hz Pulsing at 1Hz 45 900Hz Sawtooth at 1Hz
6 Continuous at 1000Hz 26 700Hz Pulsing at 2Hz 46 900Hz Sawtooth at 2Hz
7 Continuous at 1100Hz 27 1200Hz Pulsing at 0.5Hz 47 1800Hz Sawtooth at 0.5Hz
8 Continuous at 1200Hz 28 1200Hz Pulsing at 1Hz 48 1800Hz Sawtooth at 1Hz
9 Continuous at 1300Hz 29 1200Hz Pulsing at 2Hz 49 1800Hz Sawtooth at 2Hz
10 Continuous at 1400Hz 30 1700Hz Pulsing at 2Hz 50 2900Hz Sawtooth at 0.5Hz
11 600Hz~1000Hz Sweeping at 0.5Hz 31 300Hz~400Hz Alternating at 0.5Hz 51 400Hz~600Hz Calling, Delay 1Second
12 600Hz~1000Hz Sweeping at 1Hz 32 300Hz~400Hz Alternating at 1Hz 52 800Hz~1000Hz Calling, Delay 1Second
13 600Hz~1000Hz Sweeping at 2Hz 33 300Hz~400Hz Alternating at 2Hz 53 1200Hz~1400Hz Calling, Delay 1Second
14 800Hz~1200Hz Sweeping at 0.5Hz 34 600Hz~800Hz Alternating at 0.5Hz 54 1600Hz~1800Hz Calling, Delay 1Second
15 800Hz~1200Hz Sweeping at 1Hz 35 600Hz~800Hz Alternating at 1Hz 55 2000Hz~2200Hz Calling, Delay 1Second
16 800Hz~1200Hz Sweeping at 2Hz 36 600Hz~800Hz Alternating at 2Hz 56 2400Hz~2600Hz Calling, Delay 1Second
17 1400Hz~1800Hz Sweeping at 0.5Hz 37 900Hz~1100Hz Alternating at 0.5Hz 57 7 short 1 long
18 1400Hz~1800Hz Sweeping at 1Hz 38 900Hz~1100Hz Alternating at 1Hz
19 1400Hz~1800Hz Sweeping at 2Hz 39 900Hz~1100Hz Alternating at 2Hz
20 1800Hz~2400Hz Sweeping at 2Hz 40 1200Hz~1400Hz Alternating at 2Hz