12
SIGNAL LIGHT COLUMN INFTERFACE UNIT USER MANUAL

Signal Light Column Interface Unit Manual Tms

Embed Size (px)

DESCRIPTION

Signal Light Column Interface Unit Manual Tms

Citation preview

Page 1: Signal Light Column Interface Unit Manual Tms

SIGNAL LIGHT COLUMN

INFTERFACE UNIT

USER MANUAL

Page 2: Signal Light Column Interface Unit Manual Tms

< INTERFACE UNIT >

Page 3: Signal Light Column Interface Unit Manual Tms

* Mode Select

5. Set Default

* Mode Select

1. Simulate Alarm

* Mode Select

2. Set Priority

* Mode Select

3. Set Alarm Time

* Mode Select

4. Set Sound Kind

< INTERFACE UNIT DISPLAY >

* MODE SELECT

1) Push MODE button

2) Push dirction button(Left/Right)

3) MODE will be changing in order as below

4) Select MODE type you want and push SET button so that you can use the

MODE type or you can change setting by pushing SET button.

5) If you push MODE button one more, LCD screen will be off

Page 4: Signal Light Column Interface Unit Manual Tms

* Mode Select

1. Simulate Alarm

> Simulate Alarm

1. GENERAL EM'CY

> Simulate Alarm

8. TELEPHONE CALL

> Simulate Alarm

2. FIRE EM'CY

> Simulate Alarm

3. CO2 RELEASE

> Simulate Alarm

4. WATER FOG

> Simulate Alarm

5. MACHINERY

> Simulate Alarm

6. DEAD MAN

> Simulate Alarm

7. TELEGRAPH

1. Simulate Alarm

- Regardless of outside alarm signal, it virtually transmit alarm signal to each

SIGNAL LIGHT COLUMN. In this case, each SIGNAL LIGHT COLUMN is

operating as if real alarm happened.

1) Push MODE button.

2) Push SET button.

3) If you push direction button, the type of alarm you want to test will be

changing in order

Page 5: Signal Light Column Interface Unit Manual Tms

* Mode Select

1. Simulate Alarm

* Mode Select

2. Set Priority

> Set Priority

1. GENERAL EM'CY

>> GENERAL EM'CY

CANCEL : SET Key

> Simulate Alarm

1. GENERAL EM'CY

4) Select Alarm button you want to test and push SET button one more.

If you selected GENERAL EM'CY, GENERAL EM'CY signal will be transmitted

to each COLUMN and each COLUMN sounds warning alarm.

5) Push SET button one more then alarm will be off

6) If you push MODE button one more, it will return to MODE SELECTOR

screen and if you push the button one more LCD screen will be off

2. Set Priority

You can set priority for preference alarm

1) Push MODE button.

2) Push direction button(Right).

3) Push SET button.

Page 6: Signal Light Column Interface Unit Manual Tms

> Set Priority

8. TELEPHONE CALL

> Set Priority

2. FIRE ALARM

> Set Priority

3. CO2 RELEASE

> Set Priority

4. WATER FOG

> Set Priority

5. MACHINERY

> Set Priority

6. DEAD MAN

> Set Priority

7. TELEGRAPH

>>GENERAL EM'CY

<- 1 ->

>>GENERAL EM'CY

<- 2 ->

4) If you push direction button, the type of alarm you want to change priority

will be changing in order

5) Select the alarm you want to change and push SET button one more.

If you selected GENERAL EM'CY, GENERAL EM'CY will be your priority and

it will show on the screen

6) Push direction button.

Your priority alarm mode will be changed from 1 to 8

Page 7: Signal Light Column Interface Unit Manual Tms

> Set Priority

1. GENERAL EM'CY

* Mode Select

1. Simulate Alarm

* Mode Select

3. Set Alarm Time

> Set Alarm Time

1. GENERAL EM'CY

> Set Alarm Time

2. FIRE ALARM

7) Select preference Priority and push SET button

The changed mode will be saved and it will return to setting screen of

preference priority

8) If you push MODE button, it will return to MODE SELECTOR screen and if

you push one more LCD screen will be off

3. Set Alarm Time

- You can set delaying time for each alarm

- ON TIME DELAY : If setting time has passed after setting of alarm, alarm

sounds in COLUMN

- OFF TIME DELAY : When alarm was set and cleared, if setting time has

passed the alarm will be cleared in COLUMN.

1) Push MODE button.

2) Push direction button(Right) twice.

3) Push SET button.

4) If you push direction button, the type of alarm which is going to set delaying

time will be changing in order.

Page 8: Signal Light Column Interface Unit Manual Tms

> Set Alarm Time

8. TELEPHONE CALL

> Set Alarm Time

3. CO2 RELEASE

> Set Alarm Time

4. WATER FOG

> Set Alarm Time

5. MACHINERY

> Set Alarm Time

6. DEAD MAN

> Set Alarm Time

7. TELEGRAPH

>>GENERAL EM'CY

->ON:00 OFF:00

>>GENERAL EM'CY

->ON:99 OFF:00

>>GENERAL EM'CY

ON:99 ->OFF:00

5) Select alarm you want to set and push SET button one more.

If you selected GENERAL EM'CY, the current setting states of delaying time

will show up. Initial state is set to 0 second.

6) You can set time by pushing direction button and it can be set max.

99seconds.

7) After setting of ON TIME DELAY, if you push SET button the setting value

will be saved and cursor will move to OFF TIME DELAY mode

8) After setting of OFF TIME DELAY, if you push SET button the setting value

will be saved and cursor will move to OFF TIME DELAY.

Page 9: Signal Light Column Interface Unit Manual Tms

>>GENERAL EM'CY

->ON:99 OFF:05

> Set Alarm Time

1. GENERAL EM'CY

* Mode Select

1. Simulate Alarm

* Mode Select

4. Set Sound Kind

> Set Sound Kind

1. GENERAL EM'CY

9) Push MODE button.

It will move to delaying time's setting mode

10) If you push MODE button, it will return to MODE SELECTOR screen and if

you push one more LCD screen will be off

4. Set Sound Kind

- You can select the type of warning sound for each alarm

1) Push MODE button.

2) Push direction button(Right) three times.

3) Push SET button.

4) If you push direction button, the type of alarm you want to change sound will

be changing in order.

Page 10: Signal Light Column Interface Unit Manual Tms

> Set Sound Kind

8. TELEPHONE CALL

> Set Sound Kind

2. FIRE ALARM

> Set Sound Kind

3. CO2 RELEASE

> Set Sound Kind

4. WATER FOG

> Set Sound Kind

5. MACHINERY

> Set Sound Kind

6. DEAD MAN

> Set Sound Kind

7. TELEGRAPH

>>GENERAL EM'CY

<- 9 ->

>>GENERAL EM'CY

<- 1 ->

5) Select alarm you want to change and push SET button one more.

If you selected GENERAL EM'CY, the setting mode of current GENERAL

EM'CY sound will show up.

6) You can change the type of sound by pushing direction button and it can be

set 57 of different sound.

7) If you push SET button after sound setting, the setting value will be saved

and it will move to sound setting screen.

Page 11: Signal Light Column Interface Unit Manual Tms

> Set Sound Kind

1. GENERAL EM'CY

* Mode Select

1. Simulate Alarm

* Mode Select

5. Set Default

> Are you sure?

Set:Yes, Mode:No

* Mode Select

5. Set Default

10) If you push MODE button it will return to MODE SELECTOR screen and if

you push button one more LCD screen will be off

5. Set Default

All setting value will return to initial status(Default)

.

1) Push MODE button.

2) Push direction button(Right) 4times.

3) Push SET button.

4) If you push SET button, it will be default and LCD Display will be off.

5) If you push MODE button, it will be out to Set Default.

6) If you push MODE button, it will return to MODE SELECTOR screen and LCD

screen will be off if you push one more.

Page 12: Signal Light Column Interface Unit Manual Tms

Signal Light Column Sound Table

NO. Frequency Timbre NO. Frequency Timbre NO. Frequency Timbre

1 Continuous at 300Hz 21 200Hz Pulsing at 0.5Hz 41 500Hz Sawtooth at 0.5Hz

2 Continuous at 450Hz 22 200Hz Pulsing at 1Hz 42 500Hz Sawtooth at 1Hz

3 Continuous at 600Hz 23 200Hz Pulsing at 2Hz 43 500Hz Sawtooth at 2Hz

4 Continuous at 750Hz 24 700Hz Pulsing at 0.5Hz 44 900Hz Sawtooth at 0.5Hz

5 Continuous at 900Hz 25 700Hz Pulsing at 1Hz 45 900Hz Sawtooth at 1Hz

6 Continuous at 1000Hz 26 700Hz Pulsing at 2Hz 46 900Hz Sawtooth at 2Hz

7 Continuous at 1100Hz 27 1200Hz Pulsing at 0.5Hz 47 1800Hz Sawtooth at 0.5Hz

8 Continuous at 1200Hz 28 1200Hz Pulsing at 1Hz 48 1800Hz Sawtooth at 1Hz

9 Continuous at 1300Hz 29 1200Hz Pulsing at 2Hz 49 1800Hz Sawtooth at 2Hz

10 Continuous at 1400Hz 30 1700Hz Pulsing at 2Hz 50 2900Hz Sawtooth at 0.5Hz

11 600Hz~1000Hz Sweeping at 0.5Hz 31 300Hz~400Hz Alternating at 0.5Hz 51 400Hz~600Hz Calling, Delay 1Second

12 600Hz~1000Hz Sweeping at 1Hz 32 300Hz~400Hz Alternating at 1Hz 52 800Hz~1000Hz Calling, Delay 1Second

13 600Hz~1000Hz Sweeping at 2Hz 33 300Hz~400Hz Alternating at 2Hz 53 1200Hz~1400Hz Calling, Delay 1Second

14 800Hz~1200Hz Sweeping at 0.5Hz 34 600Hz~800Hz Alternating at 0.5Hz 54 1600Hz~1800Hz Calling, Delay 1Second

15 800Hz~1200Hz Sweeping at 1Hz 35 600Hz~800Hz Alternating at 1Hz 55 2000Hz~2200Hz Calling, Delay 1Second

16 800Hz~1200Hz Sweeping at 2Hz 36 600Hz~800Hz Alternating at 2Hz 56 2400Hz~2600Hz Calling, Delay 1Second

17 1400Hz~1800Hz Sweeping at 0.5Hz 37 900Hz~1100Hz Alternating at 0.5Hz 57 7 short 1 long

18 1400Hz~1800Hz Sweeping at 1Hz 38 900Hz~1100Hz Alternating at 1Hz    

19 1400Hz~1800Hz Sweeping at 2Hz 39 900Hz~1100Hz Alternating at 2Hz    

20 1800Hz~2400Hz Sweeping at 2Hz 40 1200Hz~1400Hz Alternating at 2Hz