Water Technologies
Forty-X™ Disc FilterHigh Quality, High Volume Filtration In Less Space
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 4/25
Drawing on more than three decades of experience
in woven media filtration technology, the Forty-X™
disc filter provides a simple and highly reliable
filtration system.
At the heart of each Forty-X™ disc filter, individual
media panels—with integral frames—support the
woven media and ensure the geometry of the
pleated surface. The media panels are a molded one
piece construction with structural stiffeners through the
center of the panel area. This unique pleated design
reduces the opportunity for fabric tear-out and effluent
contamination. The pleated media design increases the
true cloth area available for filtration by 40% over flat
panel designs. This assures a more sustainable operation
in terms of throughput, better feed distribution, and
fewer backwash cycles.
The Forty-X™ disc filter uses pleated, woven media in a unique inside-outconfiguration, which provides maximum disc filter performance, whileeasily rejecting troublesome inorganic material.
The pleated surface of the Forty-X™
disc filter panels dramatically
multiplies the filtration surface
area.
The inside-out flow of the Forty-X™ disc
filter panels effectively captures suspended
solids and adds to backwashing efficiency.
Real World Performance and LowCost Operation Maximizes Benefits
of Disc-Type Filtration,
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 5/25
Each circular disc assembly is made up of 28 media
panels. The media panels are mounted on the central
influent drum to form the individual circular discs. The
number of circular disc assemblies mounted on the
central influent drum range from 1 to 24, depending
on the scale of the installation.
In operation, influent flows through openings in the
central drum, into the center of each media panel and
then flows out through the filter media as high quality
filtrate. This provides an inside-out flow, which
captures solids on the inside of the filter panel and
makes these solids far easier to remove during
backwashing cycles.
The inside-out filtration flow, combined with the
dynamics of the central influent drum adds further
to the simplicity of the Forty-X™ disc filter by
eliminating the need for a separate system for
handling floating and sinking material. The Forty-X™
disc filter effectively isolates trash so it is easily and
quickly transferred to the reject flow.
The Forty-X™ disc filter configuration minimizes
lifetime costs with fewer moving parts and lower
energy demands for backwashing. Wind-safe sliding
covers provide easy access to the interior, making
inspection of the media panels, quick release spray
nozzles and the centralized lubrication block simple.
With the Forty-X™ disc filter, the filtrate is always
accessible and in plain view.
Solids are Captured onthe Inside of the MediaPanels
Twice the Headloss Toleranceof Other Disc Filters
Pleated Filter
Back Wash
Spray Bar
Back Wash
Water Return
Maintenance
Friendly Seal
Influent
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 6/25
The Forty-X™ disc filter frame-only design is an ideal
drop-in retrofit for existing traveling bridge filtersand provides an easy retrofit for most other
conventional filtration systems. This is because of
the exceptionally small footprint relative to the high
volume filtration capacity of the Forty-X™ disc filter.
Also, the micron-rated media panels can be
changed-out when filtration requirements change.
Designed, engineered, and constructed by the
skilled Siemens Water Technologies team, the
Forty-X™ disc filter represents world-class quality in
every respect.
The Forty-X™ disc filter is Title 22 approved.
The modular design of the Forty-X™ disc filter
offers flexibility for a broad range of flows
and applications including: municipal tertiaryfiltration, water reuse and process water
filtration.
More Filtration In LessSpace
Circular Disk Assembly
Effluent
Central Influent Drum
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 7/25
High quality, high volume filtration is becoming increasinglyimportant to all industry professionals. Quality tertiary filtration is
now necessary to meet many effluent requirements and the need for
water reuse is well documented for most areas. In addition, the
advantages of industrial process water filtration have become more
widely recognized.
For decades, deep-bed sand filtration was one of the few effective
options, however this method had the distinct disadvantage of
requiring a large area of physical space. Today, there are a number of
other filtration options, many of which pack a tremendous amount of
filtration capacity into an extremely small physical space. Among the
most practical and efficient are disc-type filtration units.
Typically, disc-type filtration units employ rotating, unitized screened-
panels as the filtration media. Each specific manufacturer of these
now popular disc-type filtration units is unique relative to the form of
filtration media used and in the engineering of their individual units.
Some disc filters depend on a pile-type media for filtration, which has
the disadvantage of highly variable filtration capabilities owing to therandom variability of the pile media.
Disc filter units that incorporate woven-type media provide the most
consistent effluent for most filtration applications as the result of
their absolute cloth media rating.
Among disc filter units using woven-type media there are two
options, flat media and pleated media. The obvious advantage of
pleated media is that it increases the true cloth area available forfiltration by 40% over flat panel designs. Plus, pleated media is
structurally more durable and can easily withstand much higher
headloss conditions than other media configurations.
For these reasons, the Forty-X™ disc filter is engineered around
pleated, woven-type media, which allows high volume, high quality
absolute filtration as well as long term, trouble-free operation.
An absolute media rating is providedwith woven media. (10-micronopenings shown.)
Rating is nearly impossible with pilemedia.
The pleated surface increases thetrue cloth area available for filtrationby 40% over flat panel designs.
Woven Media Provides AbsoluteFiltration Results
Pleated Woven Media Multipliesthe Filtration Surface Area
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 8/25
www.siemens.com/forty-x
Forty-X is a trademark of Siemens, its
subsidiaries or affiliates.
The information provided in this brochure
contains merely general descriptions or
characteristics of performance which in actual
case of use do not always apply as described
or which may change as a result of further
development of the products. An obligation toprovide the respective characteristics shall
only exist if expressly agreed in the terms of
the contract.
Tel: 229.226.5733
Toll Free: 1.800.841.1550
E-mail: [email protected]
©2009 Siemens Water Technologies Corp.
BC-FORTYX3-BR-0809
Subject to change without prior notice.
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 9/25
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 10/25
www.siemens.com/forty-x
Forty-X is a trademark of Siemens, its subsidiaries or affiliates.
The information provided in this literature contains merely general
descriptions or characteristics of performance which in actual case
of use do not always apply as described or which may change as a
result of further development of the products. An obligation to
provide the respective characteristics shall only exist if expressly
agreed in the terms of the contract.
SiemensWater Technologies1828 Metcalf AvenueThomasville, GA 31792Tel: 229-226-5733Toll Free: 1-800-841-1550Fax: [email protected]
© 2009 Siemens Water Technologies Corp.
BC-FXFdr-DS-0609
Subject to change without prior notice.
Features
Small footprint
Innovated pleated panel filter design
provides more filtration area than
existing woven disc filters
Woven polyester media with absolute
micron rating
Trash tolerant filter panel housing
Modular design offers flexibility and
expandability of unit
Suitable for retrofit of existing
conventional filters
Wind safe sliding arch covers for easy access
and maintenance
Aeration
Reactor
Secondary
Clarifier
Wastewater
Influent
Effluent to
Reuse
WAS
RAS
Primary
Clarifier
Disc
Filter
TSS10-30 mg/l
TSS<5 mg/l
Front View Rear View
89.75"
Rejectnozzle
Feednozzle
Drain
Control
panel
Filtratenozzle
Drivecover
Strainer
Forty X Model 1403 1406 1412 1418 1424
Maximum Number of Discs per unit 3 6 12 18 24
True Cloth Filtration Area 135 ft2 13 m2 270 ft2 25 m2 538 ft2 50 m2 808 ft2 75 m2 1077 ft2 100 m2
Influent & Effluent Flange Size 10 in 250 mm 14 in 350 mm 20 in 500 mm 24 in 600 mm 30 in 700 mm
Backwash Pump Power HP @ 60 Hz 5 HP 3.7 kW 10 HP 5.6 kW 15 HP 11.2 kW 25 HP 14.9 kW 30 HP 22.4 kW
Typical Reject 0.5 - 2 % of Flow
Number of Spraybars 1 1 2 3 4
Dimensions
Tank Length 122 in 3099 mm 149 in 3785 mm 213 in 5410 mm 289 in 7341 mm 353 in 8966 mm
Tank Width 89.75 in 2280 mm 89.75 in 2280 mm 89.75 in 2280 mm 89.75 in 2280 mm 89.75 in 2280 mm
Tank Height 100.2 in 2545 mm 100.2 in 2545 mm 100.2 in 2545 mm 100.2 in 2545 mm 100.2 in 2545 mm
Frame Length - Concrete unit 122 in 3099 mm 149 in 3785 mm 213 in 5410 mm 277 in 7036 mm 341 in 8661 mm
Easy to operate and maintain
Non-metallic chain / sprocket
Stainless steel tank or stainless steel frame designs
Typical flow diagram for wastewater treatment
Backwash
Pump100.2"2545 mm
2280 mm
SlidingCovers
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 11/25
UV Disinfection SystemsTAK Series
Main Application:
Disinfection of Waste Water
IT T Industries Engineered for life
WEDECO
DIN EN ISO 9001
DIN EN ISO 14001
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 12/25
2IT T Industries
Engineered for life
WEDECO
Worldwide largest UV system for waste water in Manukau, New Zealand.(Capacity: 14 m3/s)
Typical total (TC) and fecal (FC) coliformreduction through a domestic waste
water treatment plant
10
10
10
10
10
10
10
10
2
1
0
3
4
5
6
7
R a w W a s t e w a t e r
M e c h a n i c a l t r e a t m e n t
B i o l o g i c a l t r e a t m e n t
C l a r i f i c a t i o n
S a n d f i l t r a t i o n ( o p t i o n a l )
U V D i s i n f e c t i o n
TC
Total Coliforms/100ml
Fecal Coliforms/100ml
FC
TC
FC
U.S.EPA limit
EC Goals
To effectively protect rivers, lakes,
coastal waters and ultimately the
public health, municipal waste water
must be disinfected before release to
the environment. Biological
treatment, even when combined
with clarification and filtration, does
not provide adequate removal or
inactivation of dangerous bacteria
and viruses. Where waste water
can enter bathing or drinking water
resources, the risk of human infec-
tion makes disinfection prior to
discharge an absolute necessity.
Waste water reuse for irrigation
and other purposes is increasingly
required to meet the needs of rapidly
expanding population sizes,
especially in arid climates. Provided
there is a disinfection system in place
to safeguard water quality, reuse
represents a positive, safe method of
water conservation that is set toincrease dramatically in the future.
X-rays
100 200 280 315 400 780
Wavelength (nm)
Vacuum-UV
UV-C UV-B
UV-A
Ultraviolet Visible Light Infrared
Hg-low pressurelamp 254 nm
Spectral curve ofcell inactivation
UV light inactivates harmful bacteria and viruses within seconds
TAK – The ultimate solution for waste water disinfection
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 13/25
3IT T Industries
Engineered for life
WEDECO
Natural disinfectionwithout chemicals
Ultraviolet technology provides a
proven, accepted and
environmentally friendly method of
disinfecting waste water. Whenexposed to UV-C light,
microorganisms are inactivated
within seconds through a physical
reaction with the organisms’ DNA.
In contrast to chemical disinfection,
UV produces no harmful by-
products. It also eliminates the risk
for opera- tors associated with
handling dangerous chemicals. Two
major advantages of UV disinfection
versus chemical methods are
increased disinfection effectiveness
(especially against viruses) as well as
space-savings due to shorter reaction
times. Since no chemicals are
introduced into the water, no ”post-
treatment” is required to remove
these chemicals before discharge to
the environment.
Effective and economicultraviolet systems
WEDECO has more than 20 years
of experience in the development
and application of UV technology.
The TAK series was specificallyengineered for the disinfection of
municipal waste water. Several
different TAK design configurations
are available to meet worldwide
regulatory requirements (e.g.
European bathing water guidelines,
WHO guidelines for irrigation,
California’s Title 22 for waste water
reclamation, etc.) and cope with
varying degrees of water quality
depending on the level of pretreat-ment (e.g. primary, secondary or
tertiary). Installed in final effluent
channels, the modular design of the
TAK allows for practically unlimited
flow capacities.
A d e n i n e
T h y m i n e
A d e n i n e
T h y m i n e
T h y m i n e
C y t o s i n e
T h y m i n e
Dimer
G u a n i n e
A d e n i n e
A d e n i n e
C y t o s i n e
G u a n i n e
C y t o s i
G u a n i n
n
A d e n i n e
T h y m i n e n
U V l i g h t
A d e n i n e
T h y m i n e
A d e n i n e
T h y m i n e
T h y m i n e
C y t o s i n e
T h y m i n e
G u a n i n e
A d e n i n e
A d e n i n e
C y t o s i n e
G u a n i n e
C y t o s i
G u a n i n
n
A d e n i n e
T h y m i n e n
Ultraviolet light destroys microorganisms by changing their geneticinformation (DNA)
Fully equipped UV module with UV sensor
and wiping system
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 14/25
4IT T Industries
Engineered for life
WEDECO
Throughout the world, WEDECO TAK
systems demonstrate their
effectiveness and reliability every day
of the year.
The design of any UV system starts
with the selection of the right lamp
technology. The lamp in turn is only
as good as the ballast that powers it.
This lamp/ballast combination and
the available control philosophy willdetermine the performance,
operating costs and reliability of the
UV system. Since UV light can only
disinfect properly when it can enter
the medium unhinderedly, the
overall performance of a UV system
is also dependent on the
effectiveness and reliability of its
automatic cleaning (i.e. wiping)
system. TAK series disinfection
systems utilize the most advanced
technology available in all four of
these critical areas.
Spectrum of a medium pressure UV lamp
Medium Pressure Lamp
200
Spectral curve ofcell inactivation
250 300 350 400 450 500 550 600
Wavelength [nm]
0
10
20
30
40
50
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
R e l a t i v e U
V e m i s s i o n ( % )
D N A
a b s o r b t i o n ( % )
Spektrotherm® Lamp
200
254 nm Spectral curve ofcell inactivation
250 300 350 400 450 500 550 600
Wavelength [nm]
0
10
20
30
40
50
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
R e l a t i v e U V e m i s s i o n ( % )
D N A
a b s o r b t i o n ( % )
Spectrum of a Spektrotherm® UV lamp
High performance variable output
Spektrotherm® UV lamp
At the heart of every TAK system
are WEDECO high performance
Spektrotherm® lamps. These high
intensity, low pressure amalgam
lamps combine the advantages of
conventional mercury lamp tech-
nologies while eliminating their
disadvantages.
WEDECO’s extensive research and
development program has delivered
maximum UV-C output and superior
energy efficiency from
Spektrotherm® lamps. A single
Spektrotherm® lamp will deliver
four to five times more UV-C energy
than a typical low pressure mercury
lamp while maintaining the same
electrical efficiency.
WEDECO’s specialty: Providing the most effective solution
• Safe, chemical-free operation
• Excellent disinfection results
• Drastically reduced design/
construction costs
• Easy installation of compact,
modular components in open
channels
• Low operation and
maintenance costs
• Fully automatic operation
• Design flexibility to meet
customer equirements
TAK ADVANTAGES
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 15/25
IT T Industries Engineered for life
WEDECO
5
Autom. wiping system UV module
Junction box
WEDECO’s modular waste water disinfection system TAK
Water level
Like Spektrotherm® lamps, medium
pressure mercury lamps (”multi-
wavelength” lamps) also emit a very
high UV output. However, a signi-
ficant portion of their energy
output consists of wavelengths
outside
the effective disinfection region of
the electromagnetic spectrum. This
non-productive energy leads to
higher electrical operating costs and
installation of a larger electrical
service to the system.
WEDECO Spektrotherm® lamps and
ballasts also feature variable output
control to precisely match changes
in flow rate and/or water quality.
This technology truly provides
”The Best of Both Worlds”.
WEDECO continues to set the pace
in UV technology development. No
other company can match
WEDECO’s 15 plus years of ”Low
Pressure High Intensity”
(Spektrotherm®) ultraviolet lamp
experience.
This results in:
• Fewer lamps required
• Reduced design/construction
costs
• Savings in operating and
maintenance costs
• Lower installation costs
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 16/25
Chemical-free WipingSystem
One of the most important features
in state-of-the-art UV systems for
waste water is automatic cleaning to
keep the equipment performing well
day-in and day-out. The TAK series’
automatic wiping system performs
this function like no other.
Employing specially designed wiper
rings, it prevents organic and
inorganic deposits from
accumulating on the lamp protective
quartz sleeves. This ensures that the
UV light actually reaches the water.
The TAK series’ wiping systems are
designed to operate continuously
without disrupting the disinfection
process. Wiping frequency and
”wipes per cycle” are fully fieldadjustable to match specific waste
water characteristics. Even when
lamp banks are in ”stand-by” mode,
their quartz sleeves are automatically
kept clean and ready for operation.
The smooth, reliable operation of the
TAK wiping system is due largely to
its use of a high performance
pneumatic drive and ”torsion-free”
floating wiper array.
Smart Ballast Operation
TAK systems employ WEDECO’s
advanced variable output electronic
ballast, developed specifically to
operate Spektrotherm® lamps. It
offers a multitude of unique features
for maximum system performance
and reliability.
These include:
• Very low power losses for
increased efficiency
• Infinite adjustment of UV lamp
output
• ”Smart” automatic lamp
restart on ignition failure
• High output stability for long
lamp life
• Lamp failure detection
• Very high power factor
(>0.98)
• Ease of maintenance
The result is perfectly clean quartz
sleeves, completely without
chemicals.
The degree of micro-organism
inactivation in a UV system is a
function of the UV dose received
by the organisms:
UV dose = UV intensity x Retention
[J/m2] [W/m2] [s]
”Connect and disinfect” - electronicballast for the ideal operation of theSpektrotherm® UV lamp
Continuous UV intensity measurementfor active UV dosing control
Reliable operation even under severeconditions
6IT T Industries
Engineered for life
WEDECO
• Most efficient UV lamp
technology
• Longer guaranteed lamp life
• Smart variable power ballasts
• Reliable and trouble-free
operation
• Completely chemical free
• Operator-friendly operation
and maintenance
ADVANTAGES
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 17/25
Reliable and intelligentdisinfection control
The UV intensity to which an
organism is exposed is dependent on
the lamp output, quartz sleeve
cleanliness and effluent UV
transmittance. By using dedicated UV
intensity sensors mounted within thelamp arrays, each of these variables
is automa-tically incorporated into
the measured intensity value.
Exposure time is derived from the
ratio of the UV system ”reactor”
volume to the effluent flow rate. The
resulting UV dose can be calculated
by the control system as a product of
the measured UV intensity and
exposure time.
Maintenance without tools: easyreplacement of lamps, quartz sleeves andwiper rings due to clip mechanism
IT T Industries Engineered for life
WEDECO
7
Calibrated UV intensitymonitoring system
To ensure reliable monitoring of the
UV intensity, TAK systems utilize
automatically cleaned, calibrated
intensity sensors developed by
WEDECO. The sensor features
include excellent UV selectivity,operational stability and a long
operating life.
Arrangement of electronic ballastsinside an electrical cabinet
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 18/25
8IT T Industries
Engineered for life
WEDECO
reliable and automatically cleanedWEDECO intensity sensors.
TAK systems’ electronic ballast
and system control enclosures offer
maximum flexibility to design
engineers while presenting an
intrinsically operator friendly design
approach. Available in a variety of
NEMA or IP ratings, they provide
convenient front access and a neat,
logical component layout for
routine maintenance in a clean, dry
and safe environment. To ensure
long-term, reliable operation of the
system electronics, WEDECO is
pleased to engineer a cooling
solution to meet any installation
location and local climatic
requirements.
WEDECO is also able to provide pre-
fabricated stainless steel channels
to house the UV lamp modules,including integrated inlet and outlet
transition chambers and fixed weir
level controls. This option is
generally selected for smaller
TAK systems where the provision of
a concrete channel is not desirable.
With most TAK systems, WEDECO
provides precise level control
technology engineered to meet
project specific hydraulic andperformance criteria. Weir designs
include fixed "finger” or pipe weirs,
downward opening gate weirs and
variable orifice plate weirs, among
others.
WEDECO TAK 55 UV modules in the water
Custom engineered solution
• True ”intensity based” dose
pacing control
• No overdosing or underdosing
concerns
• Automatically cleaned
intensity sensor
Additional TAKAdvantages
True dose pacing
The TAK series is unique in its
ability to provide true ”dose-paced”
system control. This intensity-based
control technology actively monitors
and controls the UV dose delivered
to micro-organisms by measuring
the ultraviolet intensity within the
UV system itself. The system adjusts
lamp power automatically (up or
down) to compensate for intensityfluctuations caused by changes in
water quality, lamp ageing or quartz
sleeve cleanliness.
Control systems that utilize a flow
signal alone (”flow pacing”) or in
combination with water trans-
mittance cannot provide accurate
”dose-pacing” due to their
ignorance of critical variables
including actual quartz sleeve
transmittance and UV lamp output.
The TAK systems are able to employ
true ”dose-pacing” as a result of
their exclusive use of accurate,
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 19/25
9IT T Industries
Engineered for life
WEDECO
WEDECO TAK system atChristchurch, UK
Channel covering(by others)
UV-Modules
Downward openingpenstock
Compressor forwiping system
Electrical cabinets
Junction box
Baffle plate
WEDECO TAK system at BadTölz, Germany
Example installation TAK 55
WEDECO System TAK 55: Waste water
disinfection in Cassano Spinola / Italy.
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 20/25
Monitoring and control systems
WEDECO offers design engineers maximum flexibility regarding
System Control & Data Acquisition (SCADA) and telemetry systems.
All TAK systems are equipped with integrated PLC systems and
intuitive local operator controls. System monitoring can be
accomplished either locally or remotely depending on project
specific requirements.
Water treatment with UV in Manukau,New Zealand
UV modules inmaintenance position
Supervision and maintenance via
modem connection
10IT T Industries
Engineered for life
WEDECO
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 21/25
Ease of maintenance
In the development of WEDECO
products, special attention is
always devoted to maintenance
considerations. The successful
operation of any UV system is
dependent upon the frequency
as well as the ease of maintenance.
In TAK systems WEDECO has
succeeded in minimizing main-
tenance requirements through the
use of advanced technology, quality
engineering and construction. The
long life of Spektrotherm® lamps,
exceptional ballast reliability,
superior lamp module construction
and an extremely effective wiping
system all serve to minimize the time
and costs to maintain a TAK system.
WEDECO accomplished much of the
timesavings simply by designing the
TAK system to provide easy access to
all system components.
Worldwide service
The WEDECO Group has delivered
and supports more than 100,000
UV systems throughout the world.
Regardless of your location, WEDECO
strives to provide every customer
with world-class service, before and
after the sale. Company trained
WEDECO staff and partners are
stationed in almost every region of
the world to provide responsive and
professional support.
11
WEDECO Global Customer Service:
Professional and fast local support for our customers
11IT T Industries
Engineered for life
WEDECO
WEDECO support andservice capabilities:
• Customized long-term
service contracts
• Certified operator
training courses
• Defined service call-outs
• Holding of consignment stock
• Free return/recycling of used
WEDECO lamps
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 22/25
IT T Industries Engineered for life
WEDECO
DIN EN ISO 9001
DIN EN ISO 14001
Diese Broschüre wurde Ihnen überreicht durch:
CONTACTS
AUSTRALIA / SOUTH-EAST ASIA
Unit 31, Slough EstateHolker StreetSilverwater NSW 2128AustraliaTel.: +61 2 9631 4455Fax: +61 2 9631 4466E-mail: [email protected]
AUSTRIA
Seyrlstrasse 2A-4863 Seewalchen am AtterseeTel.: +43 7662 5626Fax: +43 7662 5626-20E-mail: [email protected]
CHINA
1107-1108 Central PlazaNo. 227 North Huang Pi RoadShanghai, 200003ChinaTel .: +86 21 6375 8880-13Fax: +86 21 6375 9028E-mail: [email protected]
GERMANY
Boschstr. 4D-32051 HerfordTel.: +49 5221 930-0Fax: +49 5221 930-131E-mail: [email protected]
FRANCE
29-31 boulevard de la MuetteF-95145 Garges-lès-GonesseTel.: +33 01 30111450Fax: +33 01 39936133
E-mail: [email protected]
GREAT BRITAIN
Churchfield RoadChilton Industrial EstateSudburyGB-Suffolk CO10 2YATel.: +44 1787 376259Fax: +44 1787 881452E-mail: [email protected]
Unit 7, Mercury Park Mercury WayUrmstonGB-Manchester M41 7LY Tel.: +44 16 1865 5000Fax: +44 16 1865 5500
HUNGARY
P.O. Box 286H-2601 VacTel.: +36 27 3176 11Fax: +36 27 31658 0E-mail: [email protected]
ITALY
North:Via Caduti sul lavoro, 27I-20099 Sesto San Giovanni (MI)Tel: +39 02 24412969Fax : +39 02 24412969E-mail: [email protected]
South:Via Tridente, 22I-70125 BariTel.: +39 080 5910511Fax: +39 080 5910514E-mail: [email protected]
KOREA
99, Gosan-ri, Ohpo-eup,Gwangju-shi, Gyunggi-doKorea 464-891Tel.: +82 31 768 3588Fax: +82 31 768 3587E-mail: [email protected]
NETHERLANDS
Steenovenweg 5NL-5708 HN HelmondTel.: +31 492 472464Fax: +31 492 472635E-mail: [email protected]
NEW ZEALAND
P. O. Box 101-303NSMCAuckland 1310New ZealandTel.: +64 9 448 21 24Fax: +64 9 448 21 25E-mail: [email protected]
NORTH AMERICA
14125 South Bridge CircleCharlotte, North Carolina 28273 USA Tel.: +1 704 7167600Fax: +1 704 7167601E-mail: [email protected]
POLAND
ul. Polna 1bPL-62-025 Kostrzyn Wlkp.Tel.: +48 61 873 35 00Fax: +48 61 873 35 01E-mail: [email protected]
SPAIN
Calle Isla de la Palma 32Nave 6, Polígono Ind. NorteSan Sebastian de los ReyesE-28700 MadridTel.: +34 91 659 1800Fax: +34 91 659 1801E-mail: [email protected]
SWITZERLAND
Birkenweg 4CH-8304 WallisellenTel.: +41 (0)433557010Fax: +41 (0)433557011E-mail: [email protected]
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 23/25
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 24/25
8/11/2019 Siemens Forty X Disc Filters Tech. Specs.
http://slidepdf.com/reader/full/siemens-forty-x-disc-filters-tech-specs 25/25