6
NOTE: -MAX. PIPE CONNECTION: 27"RCP AT 0° SKEW -MADE IN ACCORDANCE WITH ASTM C913 -STEEL REINFORCEMENT: ASTM A615 GRADE 60 OR EQ. ASTM A1064 WWR -MAX BURIAL DEPTH 25'-0" FROM INSIDE FLOOR TO FINISHED GRADE -PER TxDOT PRECAST BASE DETAIL TYPE 'PB' JANUARY 2015. -STEPS NOT AVALIABLE -CAST IRON FRAME CAST INTO SLAB TOP -SMALLER FRAME & GRATE OPTIONS ARE AVAILABLE -ADA GRATE OPTION AVAILABLE. REGION, STATE DATE SECT.PAGE CENTRAL 2018 3'-0" x 3'-0" GRATE INLET - CAST IRON 36"TWKO (4 SIDES) 6" 3'-0" 6" 3'-6" 6" KNOCKOUT BASE WEIGHT 3,725# 6" 3'-0" 6" VAR RISER SECTION OPTIONAL PLAN VIEW SIDE VIEW 6" 3'-0" 6" 6" GRATE INLET TOPSLAB WEIGHT 525# RISER A WEIGHT 1'-0" 1,075# 1'-6" 1,600# 2'-0" 2,150# 3'-0" 3,225# * 36"x36" CAST IRON FRAME & GRATE 2.4.1

SIDE VIEW - Pipes & Precast Products Manufacturers

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SIDE VIEW - Pipes & Precast Products Manufacturers

NOTE:

-MAX. PIPE CONNECTION: 27"∅ RCP AT 0° SKEW

-MADE IN ACCORDANCE WITH ASTM C913

-STEEL REINFORCEMENT: ASTM A615 GRADE 60 OR EQ. ASTM A1064 WWR

-MAX BURIAL DEPTH 25'-0" FROM INSIDE FLOOR TO FINISHED GRADE

-PER TxDOT PRECAST BASE DETAIL TYPE 'PB' JANUARY 2015.

-STEPS NOT AVALIABLE

-CAST IRON FRAME CAST INTO SLAB TOP

-SMALLER FRAME & GRATE OPTIONS ARE AVAILABLE

-ADA GRATE OPTION AVAILABLE.

REGION, STATE

DATE SECT.PAGE

CENTRAL

2018

3'-0" x 3'-0"GRATE INLET - CAST IRON

36"∅ TWKO

(4 SIDES)

6"3'-0"6"

3'-6"

6"

KNOCKOUT BASE

WEIGHT 3,725#

6"

3'-0"

6"

VAR RISER SECTION

OPTIONAL

PLAN VIEW

SIDE VIEW

6"3'-0"6"

6" GRATE INLET TOPSLAB

WEIGHT 525#

RISER

A WEIGHT

1'-0" 1,075#

1'-6" 1,600#

2'-0" 2,150#

3'-0" 3,225#

* 36"x36" CAST IRON

FRAME & GRATE

2.4.1

Page 2: SIDE VIEW - Pipes & Precast Products Manufacturers

NOTE:

-MADE IN ACCORDANCE WITH ASTM C913

-STEEL REINFORCEMENT: ASTM A615 GRADE 60 OR EQ. ASTM A1064 WWR

-MAX BURIAL DEPTH 25'-0" FROM INSIDE FLOOR TO FINISHED GRADE

-PER TxDOT PRECAST BASE DETAIL TYPE 'PB' JANUARY 2015.

-STEPS NOT AVAILABLE

-ADA GRATE AVAILABLE.

REGION, STATE

DATE SECT.PAGE

CENTRAL TX

2018

3'-0" x 3'-0"GRATE INLET - GALVANIZED

36"∅ TWKO

(4 SIDES)

6"3'-0"6"

3'-6"

6"

KNOCKOUT BASE

WEIGHT 3,725#

6"

3'-0"

6"

A

PLAN VIEW

SIDE VIEW

* 41"x41" GALVANIZED

GRATE

6"3'-0"6"

RISER SECTION

OPTIONAL

RISER

A WEIGHT

1'-0" 1,075#

1'-6" 1,600#

2'-0" 2,150#

3'-0" 3,225#

WEIGHT 280#

2.4.2

Page 3: SIDE VIEW - Pipes & Precast Products Manufacturers

NOTE:

-MAX. PIPE CONNECTION: 36"∅ RCP AT 0° SKEW

-MADE IN ACCORDANCE WITH ASTM C913

-STEEL REINFORCEMENT: ASTM A615 GRADE 60 OR EQ. ASTM A1064 WWR

-MAX BURIAL DEPTH 25'-0" FROM INSIDE FLOOR TO FINISHED GRADE

-PER TxDOT PRECAST BASE DETAIL TYPE 'PB' JANUARY 2015.

-STEPS NOT AVAILABLE

-CAST IRON FRAME CAST INTO SLAB

-SMALLER FRAME & GRATE OPTIONS ARE AVAILABLE.

-ADA GRATE AVAILABLE.

REGION, STATE

DATE SECT.PAGE

CENTRAL TX

2018

4'-0" x 4'-0"GRATE INLET - CAST IRON

4'-6"

6"

KNOCKOUT BASE

WEIGHT 6,000#

A

RISER SECTION

OPTIONAL

SIDE VIEW * 48"x48" CAST IRON

FRAME & GRATE

6"4'-0"6"

6"

4'-0"

6"

4'-0"

PLAN VIEW6"6"

48"∅ TWKO

(4 SIDES)

6" GRATE INLET TOPSLAB

RISER

A WEIGHT

1'-0" 1,375#

1'-6" 2,075#

2'-0" 2,750#

3'-0" 4,125#

2.4.3

Page 4: SIDE VIEW - Pipes & Precast Products Manufacturers

NOTE:

-MAX. PIPE CONNECTION: 36"∅ RCP AT 0° SKEW

-MADE IN ACCORDANCE WITH ASTM C913

-STEEL REINFORCEMENT: ASTM A615 GRADE 60 OR EQ. ASTM A1064 WWR

-MAX BURIAL DEPTH 25'-0" FROM INSIDE FLOOR TO FINISHED GRADE

-PER TxDOT PRECAST BASE DETAIL TYPE 'PB' JANUARY 2015.

-STEPS NOT AVAILABLE

-CAST IRON FRAME CAST INTO SLAB

-ADA GRATE OPTION AVAILABLE.

REGION, STATE

DATE SECT.PAGE

CENTRAL TX

2018

4'-0" x 4'-0"GRATE INLET - CAST IRON 2 GRATE

4'-6"

6"

KNOCKOUT BASE

WEIGHT 6,000#

A

RISER SECTION

OPTIONAL

SIDE VIEW6"4'-0"6"

6"

4'-0"

6"

4'-0"

PLAN VIEW6"6"

48"∅ TWKO

(4 SIDES)

10" 2 GRATE INLET TOPSLAB

WEIGHT 3,125#

*(2) 18"x30" CASTIRON FRAMES &

GRATES w/ STEEL BEAM

RISER

A WEIGHT

1'-0" 1,375#

1'-6" 2,075#

2'-0" 2,750#

3'-0" 4,125#

2.4.4

Page 5: SIDE VIEW - Pipes & Precast Products Manufacturers

NOTE:

-MAX. PIPE CONNECTION: 36"∅ RCP AT 0° SKEW

-MADE IN ACCORDANCE WITH ASTM C913

-STEEL REINFORCEMENT: ASTM A615 GRADE 60 OR EQ. ASTM A1064 WWR

-MAX BURIAL DEPTH 25'-0" FROM INSIDE FLOOR TO FINISHED GRADE

-PER TxDOT PRECAST BASE DETAIL TYPE 'PB' JANUARY 2015.

-STEPS NOT AVAILABLE

-ADA GRATE AVAILABLE.

-GRATE DROPS INTO JOINT AND IS NOT CAST IN

REGION, STATE

DATE SECT.PAGE

CENTRAL TX

2018

4'-0" x 4'-0"GRATE INLET - GALVANIZED

4'-6"

6"

KNOCKOUT BASE

WEIGHT 6,000#

A

SIDE VIEW

* 53"x53" GALVANIZED

GRATE

6"4'-0"6"

6"

4'-0"

6"

4'-0"

PLAN VIEW

6"6"

48"∅ TWKO

(4 SIDES)

RISER SECTION

OPTIONAL

RISER

A WEIGHT

1'-0" 1,375#

1'-6" 2,075#

2'-0" 2,750#

3'-0" 4,125#

WEIGHT 452#

2.4.5

Page 6: SIDE VIEW - Pipes & Precast Products Manufacturers

6"

5'-0"

6"

60"∅ TWKO

(4 SIDES)

5'-6"

6"

A

PLAN VIEW

6"5'-0"6"

SIDE VIEW

6"5'-0"6"

KNOCKOUT BASE

WEIGHT 9,025#

NOTE:

-MAX. PIPE CONNECTION: 48"∅ RCP AT 0° SKEW

-MADE IN ACCORDANCE WITH ASTM C913

-STEEL REINFORCEMENT: ASTM A615 GRADE 60 OR EQ. ASTM A1064 WWR

-MAX BURIAL DEPTH 25'-0" FROM INSIDE FLOOR TO FINISHED GRADE

-PER TxDOT PRECAST BASE DETAIL TYPE 'PB' JANUARY 2015.

-STEPS NOT AVAILABLE

-ADA GRATE AVAILABLE.

-GRATE DROPS INTO JOINT AND IS NOT CAST IN

REGION, STATE

DATE SECT.PAGE

CENTRAL TX

2018

5'-0" x 5'-0"GRATE INLET - GALVANIZED

* 64"x64" GALVANIZED

GRATE

RISER SECTION

OPTIONAL

RISER

A WEIGHT

1'-0" 1,675#

1'-6" 2,525#

2'-0" 3,375#

3'-0" 5,050#

WEIGHT 852#

2.4.6