36

Shrunk - Amazon Web Servicesarlingtonva.s3.amazonaws.com/wp-content/uploads/sites/31/...PROJECT OWNER GRAPHIC SCALE 1 4.1 PRE-SUBMISSION 01/08/2015 NVR INC. 11700 PLAZA AMERICA DRIVE

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • S

    W W

    W

    HCR

    DN

    1A13

    2A13

    3A13

    1A12

    2A12

    142' - 4"

    RESIDENTIAL ENTRY

    FIRE DEPARTMENTCONNECTION

    TOWN HOUSE ENTRANCES TOWN HOUSE ENTRANCES

    GARAGE ENTRYLOADING DOCKENTRY

    EXISTINGTRANSFORMERRELOCATED

    MECHANICAL AREA TOBE SCREENED SIDES

    AND ABOVE. REFER TOELEVATIONS

    EXISTINGTRANSFORMERS TOBE RELOCATED

    GARAGEEXHAUST ATFACE OFBUILDING

    GARAGE INTAKE AT FACEOF BUILDING

    RESIDENTIAL EXIT STAIR

    PRIVATE OUTDOORTERRACES FOR SECONDFLOOR TENANTSONLY,TYP.

    206' - 4" 206' - 4"

    PUBLIC ALLEY

    REFER TOLANDSCAPE PLANS

    NORTH COLONIAL TERRACE

    NORTH NASH STREET

    KEY

    BOU

    LEVA

    RD

    207' - 0"

    207' - 0"

    197' - 0"

    207' - 0"

    185' - 0"185' - 0"185' - 0"185' - 0"

    185' - 0"

    174' - 4"

    174' - 4"

    185' - 0" 185' - 0" 185' - 0"

    185' - 0"

    142' - 4"

    139' - 1"

    1'-6 5/8" 20'-4 3/4" 32'-6 3/8" 17'-2 5/8" 36'-8 5/8" 8'-2 5/8" 24'-8 5/8" 6'-2 5/8" 34'-8 5/8" 16'-8" 19'-8 5/8"

    57'-2

    1/4"

    53'-8

    5/8"

    7'-9"

    31'-8

    5/8"

    150'-

    5 1/4"

    15'-11 5/8" 36'-8 5/8" 8'-6 5/8" 24'-8 5/8" 8'-2 5/8" 36'-8 5/8" 14'-6 5/8" 14'-8 5/8" 11'-6" 23'-8 5/8" 23'-3 5/8"

    218'-8 1/8"

    32'-8

    1/8"

    4'-7 5

    /8"25

    '-8 5/

    8"16

    '-11 7

    /8"15

    '-2 1/

    4"

    151'-

    4"

    110' - 3"

    15'-7 5/8" 6'-4 3/8" 15'-7 5/8" 6'-4 3/8" 15'-7 5/8" 6'-4 3/8" 15'-7 5/8" 6'-4 3/8" 15'-7 5/8" 6'-4 3/8" 15'-7 5/8" 7'-8" 16'-7 5/8" 34'-3 5/8" 10'-8 5/8" 23'-3 5/8"

    218'-3 1/8"

    1A10

    1A10

    A112

    A111

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    SITE PLAN

    A01

  • W

    HCR

    3'-0"

    3'-0"

    3'-0"

    620 SF

    TH-02 LEVEL01

    627 SF

    TH-01 LEVEL01

    627 SF

    TH-03 LEVEL01

    627 SF

    TH-04 LEVEL01

    626 SF

    TH-05 LEVEL01

    627 SF

    TH-06 LEVEL01

    319 SF

    TRANSFORMERENCLOSURE

    953 SF

    LOADINGSPACE

    340 SF

    TRASH ANDRECYCLING

    465 SF

    GAS ANDELECTRICAL

    114' - 7 1/2" 114' - 6"

    111' - 8"111' - 8"111' - 8"111' - 8"111' - 8"111' - 8"

    8 %

    GARAGEEXIT

    GARAGEENTRY

    1A13

    2A13

    3A13

    1A12

    2A12

    15'-7 5/8" 6'-4 3/8" 15'-7 5/8" 6'-4 3/8" 15'-7 5/8" 6'-4 3/8" 15'-7 5/8" 6'-4 3/8" 15'-7 5/8" 6'-4 3/8" 15'-7 5/8" 7'-8" 16'-7 5/8" 34'-3 5/8" 10'-8 5/8" 23'-3 5/8"

    31'-1

    1 1/4"

    7'-9 3

    /8"

    33'-0

    "

    KEY

    BOU

    LEVA

    RD

    NORTH NASH STREET

    TRANSFORMERRELOCATED INSIDEOF BUILDING

    111' - 8" 111' - 6" 111' - 4" 111' - 2" 110' - 8" 110' - 4"

    110' - 2"

    118' - 3 1/2"

    218'-3 1/8"

    1A10

    1A10

    A112

    A111

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    LEVEL -1

    A02

    Building FAR 96,341 2.53

    Building FAR

    Site Area 38,020Area FAR

    FAR Calculation*Loading Dock is 22' Clear Height

    Total 28,937Loading Dock 1,447Other Gross Parking Areas

    Total 27,490 62 0 2 64 30122.17 0 13,115 27 0 1 28 30131.67 1 14,375 35 0 1 36 0

    Floor Ele. Floor #GrossParkingArea

    Full Compact Handicap Total Bicycle

    Parking and Bicycle Tabulation

    Total All 125,278 99,599

    Residential MEP Area Below GradeStorage FAR Area

    Gross Area Modifications of Use FAR AreaTotals

    Total Below Grade 19,079 4,517122.17 0 19,079 4,517Below Grade Area

    Total 12,795 12,795111.67 TH-1 4,002 4,002121.83 TH-2 3,906 3,906132.00 TH-3 4,068 4,068Townhome Building

    Total 95,865 81,454131.67 1 18,591 4,216142.33 2 15,861 15,633153.00 3 16,300 15,633163.67 4 16,300 15,633174.33 5 16,300 15,633185.00 6 12,837 12,281Multifamily Building

    Floor Ele. Floor # Residential MEP Area Below GradeStorage FAR Area

    Gross Floor Area Modifications of Use FAR Area

    Above Grade Area

    Building Area

    NOTE: Unit count and size distribution is based on current market data, and issubject to change. FAR will not change in the event of a revised unit distribution.

    - 24% 38% 14% 8% 6% 10% 100%Total - 15 24 9 5 4 6 63

    Total 6 6111.67 TH-1121.83 TH-2132.00 TH-3Townhome Building

    Total 57142.33 2 3 5 2 1 1 12153.00 3 3 5 2 1 1 12163.67 4 3 5 2 1 1 12174.33 5 3 5 2 1 1 12185.00 6 3 4 1 1 9

    Floor Ele. Floor # 1 BR + D 2 BR 2 BR + D 3 BR 2 BR... TH Total Units

    Unit Mix

  • W

    HCR

    UP

    UP

    8 %

    5 %5 %

    602 SF

    TH-01 LEVEL02

    596 SF

    TH-02 LEVEL02

    602 SF

    TH-03 LEVEL02

    602 SF

    TH-04 LEVEL02

    601 SF

    TH-05 LEVEL02

    602 SF

    TH-06 LEVEL02

    60 SFELEV 1

    60 SFELEV 2

    37 SFSTORAGE

    49 SF

    PARKINGVESTIBULE 01

    268 SF

    ENTRYVESTIBULE

    232 SF

    BIKEMAINTENANCE

    ROOM

    332 SFUTILITY ROOM

    247 SF

    GARAGEINTAKE

    217 SF

    BIKESTORAGE

    ROOM

    1905 SFLOBBY

    40 SF

    PARKINGVESTIBULE 02

    42 SF

    TH VESTIBULE01

    42 SF

    TH VESTIBULE02

    42 SF

    TH VESTIBULE03

    953 SF

    LOADINGSPACE

    314 SF

    TRASH ANDRECYCLING

    465 SF

    GAS ANDELECTRICAL

    125 SFSTAIR B

    135 SFSTAIR A

    TRANSFORMERENCLOSURE

    F01

    F02

    F03

    F04

    F05

    F06

    F07

    F08

    F10

    F11

    F12

    F13

    F14

    F15

    F16

    F17

    F18

    F19

    F20

    F21

    F22

    F23

    F24

    HC25

    F26

    F27

    F28

    F09

    24'-0 7/8"

    5 % 15 %

    122' - 2" 117' - 2" 115' - 11"

    122' - 2"

    121' - 10" 121' - 10" 121' - 10" 121' - 10" 121' - 10" 121' - 10"

    1A13

    2A13

    3A13

    1A12

    2A12

    KEY

    BOU

    LEVA

    RD

    NORTH NASH STREET

    133'-3 5/8" 16'-7 5/8" 34'-3 5/8"

    31'-1

    0 3/4"

    7'-9 3

    /8"53

    '-4 3/

    8"20

    '-11 5

    /8"36

    '-4 3/

    8"

    2%

    114' - 6"114' - 7 1/2"

    118' - 3 1/2"

    23'-0

    "

    25'-9 1/4"

    122' - 2"

    39'-7

    1/4"

    7'-7 5

    /8"28

    '-3 5/

    8"12

    '-11 5

    /8"25

    '-3 5/

    8"4'-

    6 1/4"

    33'-0

    "

    62'-0 1/4" 156'-1 7/8"

    150'-

    4 1/2"

    20'-0

    "

    GARAGEEXIT

    GARAGEENTRY

    151'-

    4"

    1A10

    1A10

    A112

    A111

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    LEVEL 0

    A03

    Building FAR 96,341 2.53

    Building FAR

    Site Area 38,020Area FAR

    FAR Calculation*Loading Dock is 22' Clear Height

    Total 28,937Loading Dock 1,447Other Gross Parking Areas

    Total 27,490 62 0 2 64 30122.17 0 13,115 27 0 1 28 30131.67 1 14,375 35 0 1 36 0

    Floor Ele. Floor #GrossParkingArea

    Full Compact Handicap Total Bicycle

    Parking and Bicycle Tabulation

    Total All 125,278 99,599

    Residential MEP Area Below GradeStorage FAR Area

    Gross Area Modifications of Use FAR AreaTotals

    Total Below Grade 19,079 4,517122.17 0 19,079 4,517Below Grade Area

    Total 12,795 12,795111.67 TH-1 4,002 4,002121.83 TH-2 3,906 3,906132.00 TH-3 4,068 4,068Townhome Building

    Total 95,865 81,454131.67 1 18,591 4,216142.33 2 15,861 15,633153.00 3 16,300 15,633163.67 4 16,300 15,633174.33 5 16,300 15,633185.00 6 12,837 12,281Multifamily Building

    Floor Ele. Floor # Residential MEP Area Below GradeStorage FAR Area

    Gross Floor Area Modifications of Use FAR Area

    Above Grade Area

    Building Area

    NOTE: Unit count and size distribution is based on current market data, and issubject to change. FAR will not change in the event of a revised unit distribution.

    - 24% 38% 14% 8% 6% 10% 100%Total - 15 24 9 5 4 6 63

    Total 6 6111.67 TH-1121.83 TH-2132.00 TH-3Townhome Building

    Total 57142.33 2 3 5 2 1 1 12153.00 3 3 5 2 1 1 12163.67 4 3 5 2 1 1 12174.33 5 3 5 2 1 1 12185.00 6 3 4 1 1 9

    Floor Ele. Floor # 1 BR + D 2 BR 2 BR + D 3 BR 2 BR... TH Total Units

    Unit Mix

  • W

    HCR

    DN

    15 % F29

    F30

    F31

    F32

    F33

    F34

    F35

    F36

    F37

    F38

    F39F

    39F

    40F

    41F

    42F

    43F

    44F

    45F

    46F

    47F

    48F

    49F

    50

    HC51

    F57

    F58

    F59

    F60

    F61

    F62

    F63

    F64

    F56

    F55

    F54

    F53

    F52

    22'-11 1/2"

    5 %

    372 SFSTORAGE

    204 SF

    GARAGEEXHAUST

    125 SFSTAIR B

    135 SFSTAIR A

    627 SF

    TH-06 LEVEL03

    626 SF

    TH-05 LEVEL03

    627 SF

    TH-04 LEVEL03

    627 SF

    TH-03 LEVEL03

    627 SF

    TH-02 LEVEL03

    627 SF

    TH-01 LEVEL03

    62 SFSTORAGE

    60 SFELEV 1

    60 SFELEV 2

    237 SF

    GARAGEINTAKE

    LOADINGSPACE BELOW

    TRANSFORMERENCLOSURE

    BELOW

    131' - 8"

    131' - 8"

    94 SFSTORAGE

    168 SFLOBBY

    3078 SF

    AMENITYSPACE

    23'-0

    3/8"

    1A13

    2A13

    3A13

    1A12

    2A12

    KEY

    BOU

    LEVA

    RD

    NORTH NASH STREET

    133'-3 5/8" 16'-7 5/8" 34'-3 5/8" 10'-8 5/8" 23'-3 5/8"

    218'-3 1/8"

    31'-1

    0 3/4"

    7'-9 3

    /8"53

    '-4 3/

    8"21

    '-0"

    36'-4

    "

    150'-

    4 1/2"

    62'-0 1/4" 117'-7 7/8" 38'-6"

    218'-2 1/8"

    39'-7

    1/4"

    7'-7 5

    /8"28

    '-3 5/

    8"12

    '-11 5

    /8"25

    '-3 5/

    8"4'-

    6 1/4"

    151'-

    4"

    1A10

    1A10

    A112

    A111

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    LEVEL 1

    A04

    Building FAR 96,341 2.53

    Building FAR

    Site Area 38,020Area FAR

    FAR Calculation*Loading Dock is 22' Clear Height

    Total 28,937Loading Dock 1,447Other Gross Parking Areas

    Total 27,490 62 0 2 64 30122.17 0 13,115 27 0 1 28 30131.67 1 14,375 35 0 1 36 0

    Floor Ele. Floor #GrossParkingArea

    Full Compact Handicap Total Bicycle

    Parking and Bicycle Tabulation

    Total All 125,278 99,599

    Residential MEP Area Below GradeStorage FAR Area

    Gross Area Modifications of Use FAR AreaTotals

    Total Below Grade 19,079 4,517122.17 0 19,079 4,517Below Grade Area

    Total 12,795 12,795111.67 TH-1 4,002 4,002121.83 TH-2 3,906 3,906132.00 TH-3 4,068 4,068Townhome Building

    Total 95,865 81,454131.67 1 18,591 4,216142.33 2 15,861 15,633153.00 3 16,300 15,633163.67 4 16,300 15,633174.33 5 16,300 15,633185.00 6 12,837 12,281Multifamily Building

    Floor Ele. Floor # Residential MEP Area Below GradeStorage FAR Area

    Gross Floor Area Modifications of Use FAR Area

    Above Grade Area

    Building Area

    NOTE: Unit count and size distribution is based on current market data, and issubject to change. FAR will not change in the event of a revised unit distribution.

    - 24% 38% 14% 8% 6% 10% 100%Total - 15 24 9 5 4 6 63

    Total 6 6111.67 TH-1121.83 TH-2132.00 TH-3Townhome Building

    Total 57142.33 2 3 5 2 1 1 12153.00 3 3 5 2 1 1 12163.67 4 3 5 2 1 1 12174.33 5 3 5 2 1 1 12185.00 6 3 4 1 1 9

    Floor Ele. Floor # 1 BR + D 2 BR 2 BR + D 3 BR 2 BR... TH Total Units

    Unit Mix

  • W W

    W

    HCR

    DN

    78 SF

    ELEC. ANDTELECOM60 SF

    ELEV 2

    60 SFELEV 1

    134 SFSTAIR A

    1088 SFT-01

    802 SFT-02

    1054 SFT-03 126 SF

    STAIR B

    1161 SFT-04

    1427 SFT-05

    997 SFT-06

    807 SFT-07

    805 SFT-08

    1440 SFT-09

    995 SFT-10

    1267 SFT-11

    701 SFT-12

    58 SF

    TRASH ANDRECYCLING

    1167 SFCORRIDOR

    1A13

    2A13

    3A13

    1A12

    2A12

    KEY

    BOU

    LEVA

    RD

    NORTH NASH STREET

    147' - 4 1/2"

    218'-3 1/8"

    217'-7 3/4"

    11'-3

    5/8"

    28'-3

    5/8"

    7'-7 5

    /8"28

    '-3 5/

    8"12

    '-11 5

    /8"25

    '-3 5/

    8"

    151'-

    4"

    15'-11 5/8" 36'-3 5/8" 8'-11 5/8" 24'-3 5/8" 8'-7 5/8" 36'-3 5/8" 14'-11 5/8" 14'-3 5/8" 11'-11" 23'-3 5/8" 23'-3 5/8"

    4'-9 1/8" 49'-3 5/8"

    17'-7 5/8" 36'-3 5/8" 8'-7 5/8" 24'-3 5/8" 40'-11 1/4" 17'-1" 19'-3 7/8"

    OUTDOOR TERRACE ON LEVEL 2ONLY. FINAL LAYOUT TO BE

    DETERMINED WITH UNIT LAYOUTS

    PRIVATE OUTDOORTERRACES FOR SECONDFLOOR TENANTSONLY,TYP.

    7'-9"

    53'-3

    5/8"

    61'-0

    5/8"

    BALCONY

    BALCONY BALCONYBALCONYBALCONY

    BALC

    ONY

    BALC

    ONY

    142' - 4"

    1A10

    1A10

    A112

    A111

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    LEVEL 2

    A05

    Building FAR 96,341 2.53

    Building FAR

    Site Area 38,020Area FAR

    FAR Calculation*Loading Dock is 22' Clear Height

    Total 28,937Loading Dock 1,447Other Gross Parking Areas

    Total 27,490 62 0 2 64 30122.17 0 13,115 27 0 1 28 30131.67 1 14,375 35 0 1 36 0

    Floor Ele. Floor #GrossParkingArea

    Full Compact Handicap Total Bicycle

    Parking and Bicycle Tabulation

    Total All 125,278 99,599

    Residential MEP Area Below GradeStorage FAR Area

    Gross Area Modifications of Use FAR AreaTotals

    Total Below Grade 19,079 4,517122.17 0 19,079 4,517Below Grade Area

    Total 12,795 12,795111.67 TH-1 4,002 4,002121.83 TH-2 3,906 3,906132.00 TH-3 4,068 4,068Townhome Building

    Total 95,865 81,454131.67 1 18,591 4,216142.33 2 15,861 15,633153.00 3 16,300 15,633163.67 4 16,300 15,633174.33 5 16,300 15,633185.00 6 12,837 12,281Multifamily Building

    Floor Ele. Floor # Residential MEP Area Below GradeStorage FAR Area

    Gross Floor Area Modifications of Use FAR Area

    Above Grade Area

    Building Area

    NOTE: Unit count and size distribution is based on current market data, and issubject to change. FAR will not change in the event of a revised unit distribution.

    - 24% 38% 14% 8% 6% 10% 100%Total - 15 24 9 5 4 6 63

    Total 6 6111.67 TH-1121.83 TH-2132.00 TH-3Townhome Building

    Total 57142.33 2 3 5 2 1 1 12153.00 3 3 5 2 1 1 12163.67 4 3 5 2 1 1 12174.33 5 3 5 2 1 1 12185.00 6 3 4 1 1 9

    Floor Ele. Floor # 1 BR + D 2 BR 2 BR + D 3 BR 2 BR... TH Total Units

    Unit Mix

  • 1088 SFT-01

    802 SFT-02

    1054 SFT-03

    1161 SFT-04

    1427 SFT-05

    997 SFT-06

    807 SFT-07

    805 SFT-08

    1463 SFT-09

    1025 SFRoom

    78 SF

    ELEC. ANDTELECOM60 SF

    ELEV 2

    60 SFELEV 1

    134 SFSTAIR A

    126 SFSTAIR B

    58 SF

    TRASH ANDRECYCLING

    1A13

    2A13

    3A13

    1A12

    2A12

    15'-11 5/8" 36'-3 5/8" 8'-11 5/8" 24'-3 5/8" 8'-7 5/8" 36'-3 5/8" 14'-11 5/8" 14'-3 5/8" 11'-11" 23'-3 5/8" 23'-3 5/8"

    217'-4 1/8"

    4'-7 5

    /8"24

    '-4 5/

    8"16

    '-11 7

    /8"15

    '-2 1/

    4"

    7'-9"

    52'-4

    5/8"

    20'-4 3/4" 31'-2 3/8" 18'-6 5/8" 35'-4 5/8" 9'-6 5/8" 23'-4 5/8" 7'-6 5/8" 33'-4 5/8" 18'-0" 18'-4 5/8"

    215'-9 1/2"

    61'-2

    3/8"

    185' - 0"

    1A10

    1A10

    A112

    A111

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    LEVEL 6

    A06

    Building FAR 96,341 2.53

    Building FAR

    Site Area 38,020Area FAR

    FAR Calculation*Loading Dock is 22' Clear Height

    Total 28,937Loading Dock 1,447Other Gross Parking Areas

    Total 27,490 62 0 2 64 30122.17 0 13,115 27 0 1 28 30131.67 1 14,375 35 0 1 36 0

    Floor Ele. Floor #GrossParkingArea

    Full Compact Handicap Total Bicycle

    Parking and Bicycle Tabulation

    Total All 125,278 99,599

    Residential MEP Area Below GradeStorage FAR Area

    Gross Area Modifications of Use FAR AreaTotals

    Total Below Grade 19,079 4,517122.17 0 19,079 4,517Below Grade Area

    Total 12,795 12,795111.67 TH-1 4,002 4,002121.83 TH-2 3,906 3,906132.00 TH-3 4,068 4,068Townhome Building

    Total 95,865 81,454131.67 1 18,591 4,216142.33 2 15,861 15,633153.00 3 16,300 15,633163.67 4 16,300 15,633174.33 5 16,300 15,633185.00 6 12,837 12,281Multifamily Building

    Floor Ele. Floor # Residential MEP Area Below GradeStorage FAR Area

    Gross Floor Area Modifications of Use FAR Area

    Above Grade Area

    Building Area

    NOTE: Unit count and size distribution is based on current market data, and issubject to change. FAR will not change in the event of a revised unit distribution.

    - 24% 38% 14% 8% 6% 10% 100%Total - 15 24 9 5 4 6 63

    Total 6 6111.67 TH-1121.83 TH-2132.00 TH-3Townhome Building

    Total 57142.33 2 3 5 2 1 1 12153.00 3 3 5 2 1 1 12163.67 4 3 5 2 1 1 12174.33 5 3 5 2 1 1 12185.00 6 3 4 1 1 9

    Floor Ele. Floor # 1 BR + D 2 BR 2 BR + D 3 BR 2 BR... TH Total Units

    Unit Mix

  • 1A13

    2A13

    3A13

    1A12

    2A12

    STAIR B

    MECHANICAL AREA TOBE SCREENED SIDES

    AND ABOVE. REFER TOELEVATIONS

    197' - 0"

    15'-11 5/8" 36'-8 5/8" 8'-6 5/8" 24'-8 5/8" 8'-2 5/8" 36'-8 5/8" 14'-6 5/8" 14'-8 5/8" 11'-6" 23'-8 5/8" 23'-3 5/8"

    218'-8 1/8"

    4'-7 5

    /8"25

    '-8 5/

    8"16

    '-11 7

    /8"15

    '-2 1/

    4"

    62'-6

    3/8"

    1'-6 5/8" 20'-4 3/4" 32'-6 3/8" 17'-2 5/8" 36'-8 5/8" 8'-2 5/8" 24'-8 5/8" 6'-2 5/8" 34'-8 5/8" 16'-8" 19'-8 5/8"

    218'-8 1/8"

    53'-8

    5/8"

    7'-9"

    61'-5

    5/8"

    1A10

    1A10

    A112

    A111

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    ROOF PLAN

    A07

    Building FAR 96,341 2.53

    Building FAR

    Site Area 38,020Area FAR

    FAR Calculation*Loading Dock is 22' Clear Height

    Total 28,937Loading Dock 1,447Other Gross Parking Areas

    Total 27,490 62 0 2 64 30122.17 0 13,115 27 0 1 28 30131.67 1 14,375 35 0 1 36 0

    Floor Ele. Floor #GrossParkingArea

    Full Compact Handicap Total Bicycle

    Parking and Bicycle Tabulation

    Total All 125,278 99,599

    Residential MEP Area Below GradeStorage FAR Area

    Gross Area Modifications of Use FAR AreaTotals

    Total Below Grade 19,079 4,517122.17 0 19,079 4,517Below Grade Area

    Total 12,795 12,795111.67 TH-1 4,002 4,002121.83 TH-2 3,906 3,906132.00 TH-3 4,068 4,068Townhome Building

    Total 95,865 81,454131.67 1 18,591 4,216142.33 2 15,861 15,633153.00 3 16,300 15,633163.67 4 16,300 15,633174.33 5 16,300 15,633185.00 6 12,837 12,281Multifamily Building

    Floor Ele. Floor # Residential MEP Area Below GradeStorage FAR Area

    Gross Floor Area Modifications of Use FAR Area

    Above Grade Area

    Building Area

    NOTE: Unit count and size distribution is based on current market data, and issubject to change. FAR will not change in the event of a revised unit distribution.

    - 24% 38% 14% 8% 6% 10% 100%Total - 15 24 9 5 4 6 63

    Total 6 6111.67 TH-1121.83 TH-2132.00 TH-3Townhome Building

    Total 57142.33 2 3 5 2 1 1 12153.00 3 3 5 2 1 1 12163.67 4 3 5 2 1 1 12174.33 5 3 5 2 1 1 12185.00 6 3 4 1 1 9

    Floor Ele. Floor # 1 BR + D 2 BR 2 BR + D 3 BR 2 BR... TH Total Units

    Unit Mix

  • Level 1131' - 8"

    Level 2142' - 4"

    Level 3153' - 0"

    Level 4163' - 8"

    Level 5174' - 4"

    Level 6185' - 0"

    ROOF197' - 0"

    T.O.P.201' - 0"

    A.S.E.131' - 5"Level 0

    122' - 2"

    TH 01111' - 8"

    Level -1114' - 5"

    Turnberry Tower1881 North Nash Street

    384.83' 384.83'

    HIGHGATE TOWNHOMESNORTH COLONIAL TERRACE

    409.70'

    EXISITING 4 STORYBRICK RESIDENTIALBUILDING

    EXISTING 4 STORY BRICKRESIDENTIAL BUILDING

    EXISTING 3 STORY BRICKRESIDENTIAL BUILDING

    GRADE AT FARPROPERTY LINE

    PRO

    PER

    TY L

    INE

    PRO

    PER

    TY L

    INE

    PROPOSEDCONNECTIONBETWEEN KEYBOULEVARD ANDHIGHER ELEVATIONAT NORTHCOLONIAL TERRACE

    INTERSECTION ATNORTH NASH STREETAND KEY BOULEVARD

    12'-0

    "10

    '-8"

    10'-8

    "10

    '-8"

    10'-8

    "10

    '-8"

    9'-6"

    7'-9"

    65'-6

    3/4"

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    KEY BOULEVARD STREETELEVATION

    A08

    SCALE: 1/16" = 1'-0"1 KEY BOULEVARD ELEVATION - CONTEXT

  • Level 1131' - 8"

    Level 2142' - 4"

    Level 3153' - 0"

    Level 4163' - 8"

    Level 5174' - 4"

    Level 6185' - 0"

    ROOF197' - 0"

    T.O.P.201' - 0"

    A.S.E.131' - 5"Level 0

    122' - 2"

    TH 01111' - 8"

    Level -1114' - 5"

    158.00' GRADE BEYOND ATNORTH COLONIAL TERRACE

    FUTURE DEVELOPMENT OF1401 WILSON BOULEVARD

    390.50'

    438.00'

    EXISTING BRICKRESIDENTIALBUILDINGS

    INTERSECTION ATNORTH NASH STREETAND KEY BOULEVARD

    12'-0

    "10

    '-8"

    10'-8

    "10

    '-8"

    10'-8

    "10

    '-8"

    9'-6"

    7'-9"

    65'-6

    3/4"

    PROP

    ERTY

    LINE

    PROP

    ERTY

    LINE

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    NORTH NASH STREETELEVATION

    A09

    SCALE: 1/16" = 1'-0"1 NASH STREET ELEVATION - CONTEXT

  • Level 1131' - 8"

    Level 2142' - 4"

    Level 3153' - 0"

    Level 4163' - 8"

    Level 5174' - 4"

    Level 6185' - 0"

    ROOF197' - 0"

    T.O.P.201' - 0"

    A.S.E.131' - 5"Level 0

    122' - 2"

    TH 01111' - 8"

    TH 02121' - 10"

    TH 03132' - 0"

    Level -1114' - 5"

    NOTE: NUMBER AND STYLE OF BALCONIESAND WINDOWS SUBJECT TO CHANGE, 21%

    BUILDING WALL OPENING

    RED BRICK UTILITY SIZE , TYP.

    METAL CORNICE, TYP.

    METAL RAILING, TYP.

    FLAT LOCK METAL PANEL, TYP.

    METAL CORNICE, TYP.

    FLAT LOCK METALPANEL, TYP.

    RED BRICK UTILITY SIZEBRICK CORNICE, TYP.

    RED BRICK UTILITYSIZE BRICK, TYP.

    RED BRICK UTILITY SIZE , TYP.

    12'-0

    "10

    '-8"

    10'-8

    "10

    '-8"

    10'-8

    "10

    '-8"

    9'-6"

    7'-9"

    65'-6

    3/4"

    RED BRICK UTILITY SIZEBRICK CORNICE, TYP.

    RED BRICK UTILITYSIZE BRICK, TYP.

    GARAGE ENTRY WITHDECORATIVE ENTRY

    REFER TO A15 FOR ENLARGED1/8TH SCALE STREETFRONTAGE ELEVATION

    Level 1131' - 8"

    Level 2142' - 4"

    Level 3153' - 0"

    Level 4163' - 8"

    Level 5174' - 4"

    Level 6185' - 0"

    ROOF197' - 0"

    T.O.P.201' - 0"

    A.S.E.131' - 5"

    NOTE: NUMBER AND STYLE OF BALCONIESAND WINDOWS SUBJECT TO CHANGE, 21%

    BUILDING WALL OPENING

    RED BRICK UTILITY SIZE , TYP.

    METAL CORNICE, TYP.

    65'-6

    3/4"

    10'-8

    "10

    '-8"

    10'-8

    "10

    '-8"

    10'-8

    "12

    '-0"

    METAL RAILING, TYP.

    FLAT LOCK METAL PANEL, TYP.

    METAL CORNICE, TYP.

    FLAT LOCK METAL PANEL, TYP.

    RED BRICK UTILITY SIZE BRICKCORNICE, TYP.

    RED BRICK UTILITYSIZE BRICK, TYP.

    2'-4" x 14'-0" INTAKE LOUVER.FINAL DIMENSIONS AND LOCATION TBDBY DESIGN OF MECHANICAL SYSTEM

    RED BRICK UTILITY SIZE , TYP.

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    ELEVATIONS

    A10

    SCALE: 3/32" = 1'-0"1 EAST ELEVATION

    SCALE: 3/32" = 1'-0"2 WEST ELEVATION

  • Level 1131' - 8"

    Level 2142' - 4"

    Level 3153' - 0"

    Level 4163' - 8"

    Level 5174' - 4"

    Level 6185' - 0"

    ROOF197' - 0"

    T.O.P.201' - 0"

    A.S.E.131' - 5"Level 0

    122' - 2"

    TH 01111' - 8"

    TH 02121' - 10"

    TH 03132' - 0"

    Level -1114' - 5"

    Prop

    erty

    Line

    Prop

    erty

    Line

    65'-6

    3/4"

    12'-0

    "10

    '-8"

    10'-8

    "10

    '-8"

    10'-8

    "10

    '-8"

    9'-6"

    7'-9"

    10'-0"

    1'-6"

    METAL CORNICE, TYP.

    GREY MODULARBRICK CORNICE, TYP.

    TREE FENCE, TYP.

    METAL CORNICE, TYP.RED BRICK UTILITY SIZE, TYP.

    METAL RAILING, TYP.RED BRICK CORNICE, TYP.

    METAL FLAT LOCKPANEL CLADDING, TYP.

    METAL HEADER, TYP.METAL AND GLASS

    WINDOW SYSTEM, TYP.

    METAL CORNICE, TYP.METAL RAILING, TYP.

    RED BRICKUTILITY SIZE, TYP.

    METAL SILL, TYP.RED BRICK UTILITY SIZE

    SOLDIER COURSE PANEL,TYP.

    METAL SLAB EDGE COVER, TYP.

    RESIDENTIAL ENTRY, OFF KEY BOUELVARD

    GREY MODULARBRICK, TYP.

    METAL CORNICE, TYP.

    RESIDENTIAL ENTRY CANOPY, METAL AND GLASS

    NOTE: NUMBER AND STYLE OF BALCONIESAND WINDOWS SUBJECT TO CHANGE, 35%

    BUILDING WALL OPENING

    REFER TO A15 FOR ENLARGED1/8TH SCALE STREETFRONTAGE ELEVATION

    Level 1131' - 8"

    Level 2142' - 4"

    Level 3153' - 0"

    Level 4163' - 8"

    Level 5174' - 4"

    Level 6185' - 0"

    ROOF197' - 0"

    T.O.P.201' - 0"

    A.S.E.131' - 5"Level 0

    122' - 2"

    TH 01111' - 8"

    TH 02121' - 10"

    TH 03132' - 0"

    Level -1114' - 5"

    Prop

    erty

    Line

    Prop

    erty

    Line

    1'-6"10'-0"

    12'-0

    "10

    '-8"

    10'-7

    7/8"

    10'-8

    "10

    '-8"

    10'-7

    7/8"

    9'-6"

    7'-9 1

    /4"

    65'-6

    3/4"

    NOTE: NUMBER AND STYLE OF BALCONIESAND WINDOWS SUBJECT TO CHANGE, 20%

    BUILDING WALL OPENING

    RED BRICK UTILITY SIZE , TYP.

    LOADING SPACE ENTRY WITHDECORATIVE ENTRY DOOR

    5'-4" x 8'-4" EXHAUST LOUVERFINAL DIMENSIONS AND LOCATIONS TBD BYDESIGN OF MECHANICAL SYSTEM

    RED BRICK UTILITY SIZEQUIONS, TYP.

    RED BRICK UTILITY SIZECORNICE, TYP.

    METAL COPING, TYP.RED BRICK UTILITY SIZECORNICE, TYP.

    METAL RAILING, TYP

    METAL FLAT LOCK PANELCLADDING, TYP.

    METAL CORNICE, TYP.

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    ELEVATIONS

    A11

    SCALE: 3/32" = 1'-0"1 SOUTH ELEVATION

    SCALE: 3/32" = 1'-0"2 NORTH ELEVATION

  • Level 1131' - 8"

    Level 2142' - 4"

    Level 3153' - 0"

    Level 4163' - 8"

    Level 5174' - 4"

    Level 6185' - 0"

    ROOF197' - 0"

    T.O.P.201' - 0"

    A.S.E.131' - 5"Level 0122' - 2"

    Level -1114' - 5"

    T-02

    LOBBY

    LOBBYAMENITYSPACE

    ELEC. ANDTELECOM

    T-01 T-02 T-03 T-04T-09

    T-01 T-02 T-03 T-04T-09 ELEC. ANDTELECOM

    T-01 T-03 T-04T-09 ELEC. ANDTELECOM

    ELEV 2

    STAIR A STAIR B

    T-01 T-02 T-03 T-04T-09 ELEC ANDTELECOM

    T-09 T-01 T-02 T-03 T-04ELEC ANDTELECOM

    PRO

    PER

    TY L

    INE

    PRO

    PER

    TY L

    INE EXISTING BRICK

    RESIDENTIALBUILDINGS

    Future Development of1401 Wilson Boulevard438.00', Elevation

    LOBBY

    PARKING

    PARKING

    65'-6

    3/4"

    12'-0

    "10

    '-8"

    10'-8

    "10

    '-8"

    10'-8

    "10

    '-8"

    9'-6"

    7'-9"

    92'-2" 14'-7" 14'-0"17'-1"

    Level 1131' - 8"

    Level 2142' - 4"

    Level 3153' - 0"

    Level 4163' - 8"

    Level 5174' - 4"

    Level 6185' - 0"

    ROOF197' - 0"

    T.O.P.201' - 0"

    A.S.E.131' - 5"Level 0122' - 2"

    ENTRYVESTIBULE LOBBY

    AMENITYSPACE

    T-10 T-12

    T-10 T-12

    T-10 T-12

    T-10 T-12

    SPEED RAMP

    PARKINGDRIVE AISLE

    90'-0 7/8" 17'-3" 57'-9"

    Prop

    erty

    Lin

    e

    Prop

    erty

    Lin

    e

    EXISTING BRICKRESIDENTIAL BUILDINGS

    12'-2 1/2"

    158.00' GRADE BEYOND ATNORTH COLONIAL TERRACE

    198.00'

    186.00'

    Future Development of1401 Wilson Boulevard438.00', Elevation

    KeyBoulevard

    12'-0

    "10

    '-8"

    10'-8

    "10

    '-8"

    10'-8

    "10

    '-8"

    9'-6"

    65'-6

    3/4"

    PARKING

    PARKING

    1A12

    2A12

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    BUILDING SECTIONS

    A12

    SCALE: 1/16" = 1'-0"1 SECTION THROUGH LOBBY

    SCALE: 1/16" = 1'-0"2 SECTION THROUGH SPEED RAMP

  • Level 1131' - 8"

    Level 2142' - 4"

    Level 3153' - 0"

    Level 4163' - 8"

    Level 5174' - 4"

    Level 6185' - 0"

    ROOF197' - 0"

    T.O.P.201' - 0"

    A.S.E.131' - 5"Level 0

    122' - 2"

    TH 01111' - 8"

    TH 02121' - 10"

    TH 03132' - 0"

    Level -1114' - 5"

    GARAGE115' - 1"

    TH-01 LEVEL02

    TH-01 LEVEL01

    BIKESTORAGE

    ROOM LOBBYSTAIR A

    STAIR A TH-01 LEVEL03

    AMENITYSPACE

    STAIR A T-09T-10T-11

    T-09T-10T-11STAIR A

    T-09STAIR A

    T-09T-10T-11STAIR A

    T-11 T-10 T-09STAIR A

    80'-0"33'-8"

    Prop

    erty

    Line

    Prop

    erty

    Line

    Intersection at NorthNash Street and Key

    Boulevard

    22'-0"

    198.00'

    191.00'

    171.00'

    North Colonial TerraceBeyond

    Turnberry Tower1881 North Nash Street386.00' Elevation

    LOBBY

    AMENITYSPACE

    10'-0"

    OUTDOOR AMENITY10

    '-2"

    10'-1

    7/8"

    65'-6

    3/4"

    12'-0

    "10

    '-8"

    10'-8

    "10

    '-8"

    10'-8

    "10

    '-8"

    9'-6"

    7'-9"

    Level 1131' - 8"

    Level 2142' - 4"

    Level 3153' - 0"

    Level 4163' - 8"

    Level 5174' - 4"

    Level 6185' - 0"

    ROOF197' - 0"

    T.O.P.201' - 0"

    A.S.E.131' - 5"Level 0

    122' - 2"

    Level -1114' - 5"

    GARAGE115' - 1"

    LOADINGSPACETRASH AND

    RECYCLING

    LOADINGSPACE

    STAIR BSTORAGE

    T-05

    T-05

    T-04 T-05

    T-04T-05

    T-04T-05

    TRANSFORMER

    18'-1" 68'-0 5/8" 82'-10 3/8"35'-0 5/8"

    Prop

    erty

    Lin

    e

    Prop

    erty

    Lin

    e

    158.25'

    150.25'

    144..25'

    4'-0"

    4'-0"

    4'-0"

    4'-0"

    198.00'

    191.00'

    171.00'

    North Nash Street

    North ColonialTerrace

    Turnberry Tower1881 North Nash Street386.00' Elevation

    SPEEDRAMP

    TRASH ANDRECYCLING

    TRASH ANDRECYCLING

    TRASH ANDRECYCLING

    TRASH ANDRECYCLING

    TRASH ANDRECYCLING

    STAIR B

    CORR.

    CORR.

    CORR.

    CORR.

    CORR.

    DRIVE AISLE

    DRIVE AISLE

    TRANSFORMERENCLOSURE

    65'-6

    3/4"

    12'-0

    "10

    '-8"

    10'-8

    "10

    '-8"

    10'-8

    "10

    '-8"

    9'-6"

    7'-9"

    Level 1131' - 8"

    Level 2142' - 4"

    Level 3153' - 0"

    Level 4163' - 8"

    Level 5174' - 4"

    Level 6185' - 0"

    ROOF197' - 0"

    T.O.P.201' - 0"

    A.S.E.131' - 5"Level 0

    122' - 2"

    Level -1114' - 5"

    GARAGE115' - 1"

    372 SFSTORAGE

    204 SF

    GARAGEEXHAUST

    1161 SFT-04

    1427 SFT-05

    1161 SFT-04

    1427 SFT-05

    1161 SFT-04

    1427 SFT-05

    1161 SFT-04

    1427 SFT-05

    1161 SFT-04

    1427 SFT-05

    51'-1 5/8"34'-6 3/8" 113'-1"10'-2"

    Prop

    erty

    Lin

    e

    Stairs

    OutdoorTerrace

    RaisedPlanter

    157.00'

    150.25'

    144.25'4'-6"

    4'-0"

    4'-0"

    198.00'

    191.00'

    171.00'

    North Nash Street

    North ColonialTerrace

    Turnberry Tower1881 North Nash Street386.00' Elevation

    65'-6

    3/4"

    12'-0

    "10

    '-8"

    10'-8

    "10

    '-8"

    10'-8

    "10

    '-8"

    9'-6"

    7'-9"

    GARGAGEENTRYDRIVE AISLEPARKING

    DRIVE AISLE

    1A13

    2A13

    3A13

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    BUILDING SECTIONS

    A13

    SCALE: 1/16" = 1'-0"1 SECTION THROUGH TOWNHOMES

    SCALE: 1/16" = 1'-0"2 SECTION THROUGH LOADING

    SCALE: 1/16" = 1'-0"3 SECTION THROUGH GARAGE ENTRY

  • Prop

    erty

    Line

    100

    200

    300

    400

    100

    200

    300

    400

    Property Extents

    Future ResidentialDevelopment of 1401 Wilson

    Boulevard Beyond

    196.00'

    Future Development of 1401Wilson Boulevard Beyond

    Turnberry Tower1881 North Nash Street

    384.83'384.83'

    390.25'

    424.26'

    438.25'

    Prop

    erty

    Line

    Gallery at Rosslyn1800 North Oak Street

    328.80'

    264.40'

    210.00'

    North NashStreet

    Highgate TownhomesNorth Colonial Terrace

    190.50'

    201.00'

    177.30'Height of ExistingBuilding

    197.00' Roof Slab

    BEYOND BEYOND

    BEYOND BEYOND

    409.70'

    Fort MeyerDrive

    158.00' GRADE BEYOND ATNORTH COLONIAL TERRACE

    EXISTING OUTDOOR STAIRSERVING NORTH NASH TO THEHIGHER ELEVATION AT NORTHCOLONIAL TERRACE

    Future Development of 1401Wilson Boulevard

    390.50'

    438.00'

    201.00' 198.00'

    186.00'

    207.00'

    INTERSECTION ATNORTH NASH STREETAND KEY BOULEVARD

    100

    200

    300

    400

    100

    200

    300

    400

    131.44' Average Site Elevation

    Property Extents

    201.00'

    Intersection at North NashStreet and Lee Highway

    198.00' 196.00'

    186.00'

    166.00'

    Existing Brick ResidentialBuildings

    EXISTING BRICKRESIDENTIALBUILDINGS

    207.00'

    1 / A14

    2 / A14

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    SITE CONTEXT

    A14

    SCALE: 1" = 40'-0"1 SITE SECTION VIEWING SOUTH

    SCALE: 1" = 40'-0"2 SITE SECTION VIEWING WEST

    SCALE: 1" = 80'-0"3 SITE CONTEXT MAP

  • Level 1131' - 8"

    Level 2142' - 4"

    Level 0122' - 2"

    TH 01111' - 8"

    Level -1114' - 5"

    METAL CORNICE, TYP.

    GREY MODULARBRICK CORNICE, TYP.GREY MODULAR BRICKSOLDIER COURSE, TYP.

    GREY MODULAR BRICKROWLOCK COURSE, TYP.GREY MODULAR BRICKREVEAL PANEL, TYP.GREY MODULAR BRICKSOLDIER COURSE, TYP.

    GREY MODULAR BRICKREVEAL COURSE, TYP.

    GREY MODULAR BRICKSOLDIER COURSE, TYP.

    TREE FENCE, TYP.INTERSECTION AT

    NORTH NASH STREETAND KEY BOULEVARD

    METAL CORNICE, TYP.

    RED BRICK UTILITY SIZE, TYP.

    METAL RAILING, TYP.

    RED BRICK CORNICE, TYP.METAL FLAT LOCKPANEL CLADDING, TYP.

    METAL HEADER, TYP.

    METAL AND GLASSWINDOW SYSTEM, TYP.

    METAL CORNICE, TYP.

    METAL RAILING, TYP.

    RED BRICKUTILITY SIZE, TYP.

    METAL SILL, TYP.RED BRICK UTILITY SIZE

    SOLDIER COURSE PANEL,TYP.

    METAL SLAB EDGE COVER, TYP.

    RESIDENTIAL ENTRY CANOPY, METAL AND GLASS

    RESIDENTIAL ENTRY, OFF KEY BOUELVARD

    Level 1131' - 8"

    Level 2142' - 4"

    Level 0122' - 2"

    TH 01111' - 8"

    Level -1114' - 5"

    GARAGE115' - 1"

    METAL SILL, TYP.

    10'-8

    "9'-

    6"7'-

    9"

    GREY MODULARBRICK CORNICE, TYP.

    GREY MODULAR BRICKSOLDIER COURSE, TYP.

    GREY MODULAR BRICKROWLOCK COURSE, TYP.

    GREY MODULAR BRICKREVEAL COURSE, TYP.

    GREY MODULAR BRICKSOLDIER COURSE, TYP.

    TREE FENCE, TYP.

    GREY MODULAR BRICKREVEAL PANEL, TYP.

    GREY MODULAR BRICKSOLDIER COURSE, TYP.

    METAL COPING, TYP.

    TOWNHOME CANOPY METAL, TYP.

    RED BRICK UTILITYSIZE CORNICE, TYP.

    RED BRICK UTILITYSOLDIER COURSE, TYP.

    METAL SLAB EDGECOVER, TYP.

    RED BRICK UTILITYSOLDIER COURSE, TYP.

    DECORATIVE GARAGEENTRY, METAL

    RED BRICK UTILITYROWLOCK COURSE, TYP.

    RED BRICK UTILITY SIZE QUIONS, TYP.

    METAL TRELLIS

    CASEMENT OPENING,TYP.DECORATIVE TRANSFORMERSERVICE DOOR, METAL

    METAL AND WOOD TRELLIS

    RED BRICK UTILITYSIZE CORNICE, TYP.

    RED BRICK WEDGESHAPED BRICKCIRCULAR ARCHWINDOW, METAL ANDGLASS, TYP.

    RED BRICK UTILITYSIZE SOLDIERCOURSE, TYP. METAL RAILING,

    TYP.

    /1 A15

    /2 A15

    3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    STREET LEVELELEVATIONS

    A15

    SCALE: 1/8" = 1'-0"1 KEY BOULEVARD STREET LEVEL ELEVATION

    SCALE: 1/8" = 1'-0"2 NASH STREET LEVEL ELEVATION

  • 3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    PERSPECTIVES

    A16

    VIEW FROM NORTH OAK STREET TO KEY BOULEVARD

    VIEW FROM NORTH COLONIAL TERRACE VIEW OF NORTH NASH STREET TOWARDS KEY BOULEVARD

    VIEW OF INTERSECTION OF KEY BOULEVARD AND NORTH NASHSTREET

  • 3/32"=1' 0" SCALE

    2' 4' 8' 12' 16'0

    NUMBER ISSUE DATE

    DRAWING NUMBER

    TITLE

    PLAN NORTH

    PROJECT

    OWNER

    GRAPHIC SCALE

    1 4.1 PRE-SUBMISSION 01/08/2015

    NVR INC.11700 PLAZA AMERICA DRIVE

    SUITE 500RESTON, VA 20190

    1411-1417 KEY BOULEVARDARLINGTON, VA 22209

    Civil Engineer

    Landscape Architect

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    Architect

    LEED Consultant

    Paladino and Company51 Monroe Street, Suite 402

    Rockville, MD 20850P 240.403.0953

    Attorney

    McGuire Woods, LLP1750 Tysons Boulevard, 18th Floor

    Tysons Corner, Virginia 22102P 703.712.5000

    Contact: Tad Lunger

    VIKA Virginia, LLC8180 Greensboro Drive, Suite 200

    McLean, Virginia 22102P 703.442.7800

    Contact: Jeff Kreps

    2 4.1 RE-SUBMISSION 03/27/2015

    3 4.1 SUBMISSION 06/12/2015

    4 4.1 FINAL SUBMISSION 12/10/2015

    INFORMATION SHEET

    A17

    *Loading Dock is 22' Clear Height

    Total 28,937Loading Dock 1,447Other Gross Parking Areas

    Total 27,490 62 0 2 64 30122.17 0 13,115 27 0 1 28 30131.67 1 14,375 35 0 1 36 0

    Floor Ele. Floor #GrossParkingArea

    Full Compact Handicap Total Bicycle

    Parking and Bicycle Tabulation

    Total All 125,278 99,599

    Residential MEP Area Below GradeStorage FAR Area

    Gross Area Modifications of Use FAR AreaTotals

    Total Below Grade 19,079 4,517122.17 0 19,079 4,517Below Grade Area

    Total 12,795 12,795111.67 TH-1 4,002 4,002121.83 TH-2 3,906 3,906132.00 TH-3 4,068 4,068Townhome Building

    Total 95,865 81,454131.67 1 18,591 4,216142.33 2 15,861 15,633153.00 3 16,300 15,633163.67 4 16,300 15,633174.33 5 16,300 15,633185.00 6 12,837 12,281Multifamily Building

    Floor Ele. Floor # Residential MEP Area Below GradeStorage FAR Area

    Gross Floor Area Modifications of Use FAR Area

    Above Grade Area

    Building Area

    NOTE: Unit count and size distribution is based on current market data, and issubject to change. FAR will not change in the event of a revised unit distribution.

    - 24% 38% 14% 8% 6% 10% 100%Total - 15 24 9 5 4 6 63

    Total 6 6111.67 TH-1121.83 TH-2132.00 TH-3Townhome Building

    Total 57142.33 2 3 5 2 1 1 12153.00 3 3 5 2 1 1 12163.67 4 3 5 2 1 1 12174.33 5 3 5 2 1 1 12185.00 6 3 4 1 1 9

    Floor Ele. Floor # 1 BR + D 2 BR 2 BR + D 3 BR 2 BR... TH Total Units

    Unit Mix

    25' Setbacks from Key Boulevard,North Nash Street and NorthColonial Terrace20' Setback from Lot Boundries

    Relief from all setbacks other thanNorth Colonial Terrace

    Setbacks

    59% CoverageLot Coverage

    71 Required By-RightDwelling Units 1.02 Spaces per Dwelling Unit

    Car Parking 1.125 Spaces per Apartment 64 Proposed Parking Spaces

    27 BikesVisitors: 1 per 50 Units

    Bike Parking 1 per 2.5 Units 27 Bike Spaces Proposed

    Trash/Loading 1/200 Units or Partial 1 Trash Bay

    42.24 Units + 10.56 Units + 10.56 Units = 63.36 Units38,020/900 = 42.24 Units ADU Bonus Density: 25% of 42.24 Units Base Density = 10.56 Units900 SF Minimum Lot Area Per Unit 9,505 SF / 900 SF per Unit = 10.56 Units

    Site Area 38,020 SF LEED FAR Bonus Density: .25 * 38,020 SF = 9,505 SFUnits Per Acre

    Height 70' 66'

    Zoning Category Allowable/Required Proposed - Deviation in Italics

    Gross Parking Area (GPA) 28,937 SFFAR Floor Area (GFA) 96,341 SF (2.53 FAR)

    Site Area 38,020 Project Size (GSF) 125,278 SF

    Project Summary

    1411 - 1417 Key Boulevard, Arlington, VA

    Storage 372 SFStorage 94 SFLobby 168 SFStorage 62 SFAmenity Space 2,712 SF

    Room Data: Level 1Storage 37 SFVestibule 268 SFResidential Lobby 1,905 SFBike Maintenance Room 232 SFWater/Telecom Room 332 SFElectrical/Gas Room 465 SFBike Storage 217 SFTrash/Recycling Room 449 SFLoading Dock 1104 SFRoom Area

    Room Data: Level 0

    Room Data