41
Shoulder Procedure Tray Metro Surgical Solutions

Shoulder procedure tray 2

Embed Size (px)

Citation preview

Page 1: Shoulder procedure tray 2

Shoulder Procedure Tray

Metro Surgical Solutions

Page 2: Shoulder procedure tray 2

TABLE OF CONTENTS

In the order it is found in the tray

• TOP TRAY

• LUPINE DOVE TAIL

• LUPINE FISH MOUTH

• LUPINE SAW TOOTH

• LUPINE HYBRID

• MALLET

• RASP DOWN BEND 20 °

• TISSUE LIBERATOR ATRAUMATIC UP

• RASP UP BEND 20 °

• TISSUE LIBERATOR ATRAUMATIC DOWN

• LUPINE OBTURATOR

• T-HANDLE REAMER

• 2.9 MM AWL

• HEALIX 5.5MM AWL/TAP

• CORTICAL 5.5MM AWL/TAP

• CROCHET HOOK

• LUPINE SPIRAL FLUTED DRILL BIT

• EXPRESSEW III

• SUTURE SCISSORS

• GRASPER GRABBER-STRAIGHT

• PENETRATING GRASPER 35 ° UP

CONT’

• SUTURE MANIPULATOR

• GRASPER

• CORD CUTTER

• GRASPER PENETRATOR-STRAIGHT

• GRASPER PENETRATOR 45 ° RIGHT

• PATHSEEKER HANDLE

• KNOT PUSHER

• CROCHET HOOK

• HEALIX KNOTLESS 3.4MM

• HEALIX AWL 5.5 X55MM REUSABLE OBTURATOR

• 7.0 X 75MM REUSABLE OBTURATOR

• ARTHRO CI-CANN SWITCHSTICK 4MM

• HEALIX 4.5 MM AWL /TAP

• OBTURATOR BLACK

• HEALIX 6.5MM AWL/TAP

Page 3: Shoulder procedure tray 2

Top Tray

Page 4: Shoulder procedure tray 2

LUPINE DOVE TAIL DRILL GUIDE

Used for Slap or posterior repairs

Page 5: Shoulder procedure tray 2

LUPINE FISH MOUTH DRILL GUIDE

Surgeon preference

Page 6: Shoulder procedure tray 2

LUPINE SAW TOOTH DRILL GUIDE

Use anywhere on glenoid surgeon preference

Page 7: Shoulder procedure tray 2

LUPINE HYBRID DRILL GUIDE

Anywhere on glenoid surgeon preference

Page 8: Shoulder procedure tray 2

RASP DOWN BEND 20°

Used to get bleeding

Page 9: Shoulder procedure tray 2

Tissue Liberator – Atraumatic Up

Dull elevator to separate tissue from bone

Page 10: Shoulder procedure tray 2

RASP UP BEND 20°

Used to get bone bleeding angle

Page 11: Shoulder procedure tray 2

TISSUE LIBERATOR ATRAUMATIC DOWN

Elevator to separate bone and tisssue

Page 12: Shoulder procedure tray 2

LUPINE OBTURATOR

Place inside guide while inserting into patient

Page 13: Shoulder procedure tray 2

T-Handle reamer

Used to find or clean out a drilled hole

Page 14: Shoulder procedure tray 2

T-handle reamer

Can smooth bone if twisted when inserted into drill hole

Page 15: Shoulder procedure tray 2

2.9mm awl

Used for Bioknotless instead of drill in soft bone

Page 16: Shoulder procedure tray 2

HEALIX 5.5mm AWL/TAP

Used to tap a 5.5mm/6.5mm healixanchor

Page 17: Shoulder procedure tray 2

CORTICAL 5.5mm AWL/TAP

Used in softer humeral head only taps cortical layer

Page 18: Shoulder procedure tray 2

CROCHET HOOK

Grapping suture and manipulating it

Page 19: Shoulder procedure tray 2

LUPINE SPIRAL FLUTED DRILL BIT

2.9mm with auto stop for Lupine, bioknotless

Page 20: Shoulder procedure tray 2

EXPRESSEW III

Passing suture through RC requires disposable needle

Page 21: Shoulder procedure tray 2

Middle trayMID TRAY

Page 22: Shoulder procedure tray 2

SUTURE SCISSORS214605

Cutting ethinbond suture

Page 23: Shoulder procedure tray 2

GRASPER GRABBER-STRAIGHT270120

To grab tissue, suture or anything during the arthroscopy

Page 24: Shoulder procedure tray 2

PENETRATING GRASPER- 35°-UP214601

Also know as bird beeks, used to penetrate tissue and retrograde suture

Page 25: Shoulder procedure tray 2

SUTURE MANIPULATOR214626

Know as crab claw, robot arm, open grasper etc, used to retrieve suture

Page 26: Shoulder procedure tray 2

GRASPER214604

Used to grab suture, loose bodies and tissue

Page 27: Shoulder procedure tray 2

CORD CUTTER214646

Cutting suture in arthroscopy

Page 28: Shoulder procedure tray 2

GRASPER PENETRATOR –STRAIGHT214600

Know as bid beak, penetrating tissue and retrograding suture

Page 29: Shoulder procedure tray 2

GRASPER PENETRATOR 45° –RIGHT214603

Know as bird beak, used to penetrate tissue and retrograde suture

Page 30: Shoulder procedure tray 2

PATHSEEKER HANDLE214650

discontinued

Page 31: Shoulder procedure tray 2

Tangle KNOT PUSHER

Used to tie arthroscopic knots

Page 32: Shoulder procedure tray 2

CROCHET HOOK

Used to delicately grab and untangle knots, suture mgnt

Page 33: Shoulder procedure tray 2

Top Tray

Page 34: Shoulder procedure tray 2

HEALIX KNOTLESS AWL 3.4mm

Used for good bone with healix knotless

Page 35: Shoulder procedure tray 2

HEALIX AWL

Use before tap or in place of with soft bone

Page 36: Shoulder procedure tray 2

Use with color 5.5 X 55mm REUSABLE OBTURATOR

Use with color coded cannula to pass a switching stick through

Page 37: Shoulder procedure tray 2

7.0 X 75mm REUSABLE OBTURATOR

Use with color coded cannula to use with switching stick

Page 38: Shoulder procedure tray 2

ARTHRO CI-CANN SWITCHSTICK 4mm

Fits through the cannula obtorator to keep their place in the joint

Page 39: Shoulder procedure tray 2

HEALIX 4.5mm AWL/TAP222272

Use with healix 4.5mm anchors, not for use with advance anchors

Page 40: Shoulder procedure tray 2

OBTURATOR –BLACK

Obsolete cannula

Page 41: Shoulder procedure tray 2

HEALIX 6.5mm AWL/TAP222225