2
TM ® FOR ALL USERS • New, easy-to-use and customizable User Interface • Customizable function keys (F-keys) for quick selection of montages or other actions • No memory limits (native 64-bit application) • Interpolate any surface EEG into 10-20 system (or other) with the click of one button • Automatic High-Tesla MRI histogram correction • Exported data files contain a file history, documenting previous filenames and processing steps • Automatic creation of individual Finite Element Models (FEM) FOR CLINICIANS • Easy dipole clustering • Simultaneous display of five image data sets (full support for up to ten image data sets) • Surgical navigation systems: RGB DICOM • Source reconstruction on depth electrodes (stereo-EEG) is now possible • Workflows with Scope(*) support (*) Scopes are sets of factory defaults and macros for certain application areas. Epilepsy, ERP, and CURRY 7 scopes are provided; custom scopes can be created FOR RESEARCHERS • Faster digitization of electrode positions • Flexible signal processing sequences • New statistics on source reconstruction results and channels • New wavelet and Current Density Reconstruction (CDR) options • Improved automation: macros with jumps, loops, branches, subroutines • Stream live data to MATLAB or via TCP/IP (NetStreaming), dedicated to Brain-Computer-Interface (BCI) applications • Data files compatible with MATLAB and EEGlab NEW FEATURES USER INTERFACE • New Layout with less visual clutter • Scope support: Epilepsy, ERP, and CURRY 7 scopes are provided; custom scopes can be created • High-resolution screen support SIGNAL PROCESSING • Customizable signal processing sequence • New time-frequency wavelet analysis: Morlet, Mexican Hat, Paul • Interpolate any surface EEG into 10-20 system with the click of one button • Intracranial Grid, Stereo-EEG • Multiple video windows • File history: Exported data files contain information about previous filenames and processing steps Scope Time-Frequency Signal Processing Pipeline Dipole Clustering 3D View Why you should upgrade to CURRY 8: SOURCE RECONSTRUCTION • New head models: - individualized FEM based on tetrahedra or cubes, with support for anisotropic skull - inside sphere (for depth electrode support) - precomputed BEM head model allowing to exclude cerebellum from source analysis • New Current Density Reconstruction (CDR) methods: LAURA, swLORETA, FOCUSS, ssLOFO • New CDR dipole (“virtual electrode” , “probe”) options: regional, mirrored, representing volume-of-interest • Dipole clustering • Display dipole loadings and waveforms in 3D View • Exclude a certain volume-of-interest defined by image data markers or overlays from the allowed source space • New default brain-to-skull conductivity ratio of 25 (instead of 80) • Adjust scaling of standard surfaces and precomputed head models based on electrode locations • Export CDR and Scan results in DICOM format • Export triangle meshes (including source results) in STL format • Export source results and lead field as EEG/MEG data file AVAILABLE NOW

should upgrade CURRY 8 - Compumedics Neuroscancompumedicsneuroscan.com/wp-content/uploads/AG834...• Scope support: Epilepsy, ERP, and CURRY 7 scopes are provided; custom scopes can

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: should upgrade CURRY 8 - Compumedics Neuroscancompumedicsneuroscan.com/wp-content/uploads/AG834...• Scope support: Epilepsy, ERP, and CURRY 7 scopes are provided; custom scopes can

®

TM

®

FOR ALL USERS• New, easy-to-use and customizable User Interface• Customizable function keys (F-keys) for quick selection of montages or other actions• No memory limits (native 64-bit application)• Interpolate any surface EEG into 10-20 system (or other) with the click of one button• Automatic High-Tesla MRI histogram correction• Exported data files contain a file history, documenting previous filenames and processing steps• Automatic creation of individual Finite Element Models (FEM)

FOR CLINICIANS• Easy dipole clustering• Simultaneous display of five image data sets (full support for up to ten image data sets) • Surgical navigation systems: RGB DICOM• Source reconstruction on depth electrodes (stereo-EEG) is now possible• Workflows with Scope(*) support (*) Scopes are sets of factory defaults and macros for certain application areas. Epilepsy, ERP, and CURRY 7 scopes are provided; custom scopes can be created

FOR RESEARCHERS• Faster digitization of electrode positions• Flexible signal processing sequences• New statistics on source reconstruction results and channels• New wavelet and Current Density Reconstruction (CDR) options• Improved automation: macros with jumps, loops, branches, subroutines• Stream live data to MATLAB or via TCP/IP (NetStreaming), dedicated to Brain-Computer-Interface (BCI) applications• Data files compatible with MATLAB and EEGlab

NEW FEATURES

USER INTERFACE• New Layout with less visual clutter• Scope support: Epilepsy, ERP, and CURRY 7 scopes are provided; custom scopes can be created• High-resolution screen support

SIGNAL PROCESSING• Customizable signal processing sequence • New time-frequency wavelet analysis: Morlet, Mexican Hat, Paul • Interpolate any surface EEG into 10-20 system with the click of one button• Intracranial Grid, Stereo-EEG• Multiple video windows• File history: Exported data files contain information about previous filenames and processing steps

Scope

Time-Frequency

Signal Processing Pipeline

Dipole Clustering

3D View

Why you should upgrade to CURRY 8:

SOURCE RECONSTRUCTION• New head models: - individualized FEM based on tetrahedra or cubes, with support for anisotropic skull - inside sphere (for depth electrode support) - precomputed BEM head model allowing to exclude cerebellum from source analysis• New Current Density Reconstruction (CDR) methods: LAURA, swLORETA, FOCUSS, ssLOFO• New CDR dipole (“virtual electrode”, “probe”) options: regional, mirrored, representing volume-of-interest• Dipole clustering• Display dipole loadings and waveforms in 3D View• Exclude a certain volume-of-interest defined by image data markers or overlays from the allowed source space• New default brain-to-skull conductivity ratio of 25 (instead of 80)• Adjust scaling of standard surfaces and precomputed head models based on electrode locations• Export CDR and Scan results in DICOM format• Export triangle meshes (including source results) in STL format • Export source results and lead field as EEG/MEG data file

A V A I L A B L E N O W

Page 2: should upgrade CURRY 8 - Compumedics Neuroscancompumedicsneuroscan.com/wp-content/uploads/AG834...• Scope support: Epilepsy, ERP, and CURRY 7 scopes are provided; custom scopes can

www.compumedicsneuroscan.comwww.compumedics.com

AG83

4 Iss

ue 2

TM

Compumedics USA, Limited:5015 West WT Harris Blvd, Suite ECharlotte, NC 28269Toll Free: +1 877 717 3975Ph: +1 704 749 3200Fax: +1 704 749 3299

Compumedics Limited, Australia:Headquarters30-40 Flockhart StreetAbbotsford VIC 3067, AustraliaPh: +61 3 8420 7300Fax: +61 3 8420 7399Free Call: 1800 651 751

Compumedics Germany GmbH:Global HQ for Compumedics DWLJosef-Schüttler-Strasse 2D-78224 Singen, GermanyPh: +49 7731 79 76 9-0Fax: +49 7731 79 76 9-99

Compumedics France SAS:Rue Jean Sapidus,Bât Pythagore67400 Illkirch-GraffenstadenPh: +33(0) 981 062 869Fax: +33(0) 970 604 963

Simultaneous Display of Five Image Data Sets

Electrode Digitizer Module

Stream Live Data to MATLAB or via TCP/IP

Source Statistics in a Grid View

IMAGE DATA• Simultaneous display of five image data sets (full support for up to ten image data sets) • Automatic High-Tesla MRI histogram correction for improving intensity homogeneity • Pial surface (improved display of cortex)• Image Data rotation support for Segmentation Preview, Segmentation Result and Maximum Intensity Projection (MIP)• New grid view display option showing multiple axial slices simultaneously• Improved built-in image datasets - higher-resolution standard dataset based on ICBM-152 - new pediatric dataset for age range 0-5• Support for additional image data file formats: Freesurfer, Nifti• New option for saving image data - RGB DICOM file format (for surgical navigation systems) - DICOM tag support (name, age, birthday, etc.) - DICOM anonymization option - Save image data sets in the same coordinate space• Superimpose more than one thresholded image data set• Subtract left vs. right portions of image data

STATISTICS• New Statistics methods: Maps SnPM, CDR SnPM, temporal multiple comparison correction • Source space resampling for group studies• Single-condition testing• Channel specific statistics

ELECTRODE DIGITIZER MODULE • Fully integrated into CURRY, or usable as stand-alone software• Faster digitization of electrode positions by estimating full cap-positions from only a subset of measured electrodes• New supported devices: Polhemus Patriot and NDI Krios(*) (*) import point-cloud files from NDI software (full NDI Krios integration planned for later CURRY 8 update)

CONNECTIVITY• Stream live data to MATLAB or via TCP/IP ( Listener: CURRY, MATLAB, custom software), dedicated to Brain-Computer-Interface (BCI) applications• Stimulus presentation controls recording: initiate start/stop and impedance test• CURRY data files compatible with EEGLAB• Convert recordings into other formats (such as EDF or CNT) from within the Acquisition module

PERFORMANCE• Native 64-bit application (no memory limits)• New DirectX 11 3D graphics• Faster review and processing (file caching)• Dual acquisition (lower sampling rate for online processing)• Output files ca. 30% smaller (lossless compression)• Improved automation: macros with jumps, loops, branches, subroutines• Customizable function keys (F-keys) for quick selection of montages or other actions

Without Correction

With Correction

Automatic High-Tesla MRIHistogram Correction

Stream Live Data to MATLAB or via TCP/IP