Architecture - Engineering - Planning www.mkcinc.com
Mansfield, Ohio New Philadelphia, Ohio Powell, Ohio 419-525-1102 - phone 330-364-8871 - phone 740-657-3202 - phone 419-525-1428 - fax 330-343-3075 - fax 740-657-1717 - fax
SHOP DRAWING REVIEW
✔
REVIEWED
FURNISH AS CORRECTED
REVISE AND RESUBMIT
REJECTED
SUBMIT SPECIFIED ITEM
Date:D. LayBy: Apr 10, 2012
Comments:
This review is only for general conformance with (1) the design concept and (2) the information
given in the construction documents. Corrections or comments made on a shop drawing during
this review do not relieve the contractor from compliance with the requirements of the plans and
specifications. Approval of a specific item does not include approval of an assembly of which
the item is a component. The contractor remains responsible for: dimensions to be confirmed and
correlated at the job site; information that pertains solely to the fabrication process or to the
means, methods, techniques, sequences and procedures of construction; coordination of the
Work with that of all other trades; and performing all Work in a safe and satisfactory manner.
File Name:
033500-1 Concrete Data & Test Reports
Customer: Westview Concrete Mix Series 20% Fly AshTrial Batch Date 9-Feb-11 Application InteriorTrial Location Sprauge Plant Comp. Testing by CTL Engineering
Low point Mid point High Point
Mix Information
Cement
Portland Type I 360 440 520 LbSlag Cement Grade 100 LbType F Fly Ash 90 110 130 Lb
Cement
Aggregate
Fine 1441 1390 1316 Lb#57 1450 1450 1450 Lb#8 300 300 300 Lb
Water 284 270 265 LbW/Cm 0.63 0.49 0.41
Aggregate
Admixtures
LRWR 3 3 3 oz/100LbMRWR oz/100LbHRWR oz/100LbA.E.A 0 0 0 oz/100LbRetarder oz/100LbAccelerator oz/100Lb
Slump 4 4 3.5 In.Air Content n/a n/a 2.1 %Unit Wt. 149.8 149.6 149 lb/ft^3
Admixtures
CompressiveStrength
7 Day 5280 5380 6490 psi7 Day 5190 5410 66607 Day 5310 5340 6700 psi28 Day 7260 7350 8560 psi28 Day 6840 7380 8640 psi28 Day 7300 7390 8560 psiAverage 28 Day 7133 7373 8587 psi
Average Cylinder Density 149 150 150 lb/ft^3
CompressiveStrength
Average Cylinder Density 149 150 150 lb/ft 3
Shawn Kalyn, B.EngTechnical Service Engineer
y = -6004.4x + 10759
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
0.40 0.45 0.50 0.55 0.60 0.65 0.70
28 D
ay C
ompr
essi
ve s
tren
gth
(psi
)
Water to Cementitious Ratio
Westview Concrete Interior 100% Type I Concrete 3pt Curve
CompressiveStrength Linear (CompressiveStrength)
CTL Engineering, Inc.
3085 Interstate Parkway
Brunswick, OH 44212
Phone: 330/220-8900 Fax:330/220-8944
e-mail: [email protected] AN EMPLOYEE OWNED COMPANY
Consulting Engineers – Testing – Inspection Services – Analytical Laboratories Established 1927
CLIENT: St. Marys Cement REPORT DATE: 3/10/2011
250 Jefferson Avenue BATCH DATE: 2/9/2011
Cleveland, Ohio 44113
ATTN: Shawn Kalyn
CLIENT MIX ID: Mix 4M
PROJECT: 3 Point Curve Trials MIX TYPE: 20% Fly Ash
CTL PROJECT NO.: 11020004CLE Non-air
CONCRETE SUPPLIER: Westview Concrete Corp. CTL MIX ID: 165-2C04
MaterialBatch Weight,
Cubic Yard - SSDSource Type or Grade Specific Gravity
Percent
Absorption
Fine Agg 1390 Sand
Coarse Agg 1 1450 #57
Coarse Agg 2 300 #8
Cement 440 St. Marys Type 1
Fly Ash 110 Headwaters Class F
GGBF Slag Cement
Micro-silica
Water 270
Total (Batch Weight) 3960
Water/CM Ratio 0.49
Admixtures Dosage Rate
Admix 1 3oz/100wt
Admix 2
Admix 3
Admix 4Admix 5
Batch Time 10:40 AM 7-day 5,380 8.78 150.92
Cylinders Cast 11:00 AM 7-day 5,410 8.74 150.23
Air Temp (°F) 65 7-day 5,340 8.72 149.88
Slump (in.) 4.25 7-day average 5,380
Air Content (%) 28-day 7,350 8.72 149.88
Batch Weight (lb/yd3) 3960 28-day 7,380 8.76 150.57
Unit Weight (lb/ft3) 149.6 28-day 7,390 8.76 150.57
Concrete Temp (°F) 61 28-day average 7,370
Maurika L. Lake David A. Breitfeller, PE
Laboratory Manager Project Engineer
CTL Engineering, Inc.
Respectfully Submitted,
SAMPLES AND MATERIAL DATA SUPPLIED BY CLIENT
REPORT ON SAMPLE OF CONCRETE MIX TRIAL BATCH
Mix Design Batching Data
Type
Hardened Concrete Properties, 4" x 8" Cylinders
ASTM C 494 Type C
Brand Name
ASTM C 494 Type A/F HRWR
Euclid WR81ASTM C 494 Type A
ASTM C 260
As Received
Weight (lb)
Density
(lb/ft3)
Compressive
Strength (psi)
Fresh Concrete Properties
ASTM C 494 Type D
Offices: Ohio, Indiana, West Virginia
CTL Engineering, Inc.
3085 Interstate Parkway
Brunswick, OH 44212
Phone: 330/220-8900 Fax:330/220-8944
e-mail: [email protected] AN EMPLOYEE OWNED COMPANY
Consulting Engineers – Testing – Inspection Services – Analytical Laboratories Established 1927
CLIENT: St. Marys Cement REPORT DATE: 3/10/2011
250 Jefferson Avenue BATCH DATE: 2/9/2011
Cleveland, Ohio 44113
ATTN: Shawn Kalyn
CLIENT MIX ID: Mix 5L
PROJECT: 3 Point Curve Trials MIX TYPE: 20% Fly Ash
CTL PROJECT NO.: 11020004CLE Non-air
CONCRETE SUPPLIER: Westview Concrete Corp. CTL MIX ID: 165-2C05
MaterialBatch Weight,
Cubic Yard - SSDSource Type or Grade Specific Gravity
Percent
Absorption
Fine Agg 1441 Sand
Coarse Agg 1 1450 #57
Coarse Agg 2 300 #8
Cement 360 St. Marys Type 1
Fly Ash 90 Headwaters Class F
GGBF Slag Cement
Micro-silica
Water 284
Total (Batch Weight) 3925
Water/CM Ratio 0.63
Admixtures Dosage Rate
Admix 1 3oz/100wt
Admix 2
Admix 3
Admix 4Admix 5
Batch Time 11:15 AM 7-day 5,280 8.68 149.20
Cylinders Cast 11:30 AM 7-day 5,190 8.68 149.20
Air Temp (°F) 65 7-day 5,310 8.70 149.54
Slump (in.) 4 7-day average 5,260
Air Content (%) 28-day 7,260 8.72 149.88
Batch Weight (lb/yd3) 3925 28-day 6,840 8.70 149.54
Unit Weight (lb/ft3) 149.8 28-day 7,300 8.66 148.85
Concrete Temp (°F) 61 28-day average 7,130
Maurika L. Lake David A. Breitfeller, PE
Laboratory Manager Project Engineer
ASTM C 260
As Received
Weight (lb)
Density
(lb/ft3)
Compressive
Strength (psi)
Fresh Concrete Properties
ASTM C 494 Type D
CTL Engineering, Inc.
Respectfully Submitted,
SAMPLES AND MATERIAL DATA SUPPLIED BY CLIENT
REPORT ON SAMPLE OF CONCRETE MIX TRIAL BATCH
Mix Design Batching Data
Type
Hardened Concrete Properties, 4" x 8" Cylinders
ASTM C 494 Type C
Brand Name
ASTM C 494 Type A/F HRWR
Euclid WR81ASTM C 494 Type A
Offices: Ohio, Indiana, West Virginia
CTL Engineering, Inc.
3085 Interstate Parkway
Brunswick, OH 44212
Phone: 330/220-8900 Fax:330/220-8944
e-mail: [email protected] AN EMPLOYEE OWNED COMPANY
Consulting Engineers – Testing – Inspection Services – Analytical Laboratories Established 1927
CLIENT: St. Marys Cement REPORT DATE: 3/10/2011
250 Jefferson Avenue BATCH DATE: 2/9/2011
Cleveland, Ohio 44113
ATTN: Shawn Kalyn
CLIENT MIX ID: Mix 6H
PROJECT: 3 Point Curve Trials MIX TYPE: 20% Fly Ash
CTL PROJECT NO.: 11020004CLE Non-air
CONCRETE SUPPLIER: Westview Concrete Corp. CTL MIX ID: 165-2C06
MaterialBatch Weight,
Cubic Yard - SSDSource Type or Grade Specific Gravity
Percent
Absorption
Fine Agg 1316 Sand
Coarse Agg 1 1450 #57
Coarse Agg 2 300 #8
Cement 520 St. Marys Type 1
Fly Ash 130 Headwaters Class F
GGBF Slag Cement
Micro-silica
Water 265
Total (Batch Weight) 3981
Water/CM Ratio 0.41
Admixtures Dosage Rate
Admix 1 3oz/100wt
Admix 2
Admix 3
Admix 4Admix 5
Batch Time 11:30 AM 7-day 6,490 8.70 149.54
Cylinders Cast 11:50 AM 7-day 6,660 8.64 148.51
Air Temp (°F) 65 7-day 6,700 8.76 150.57
Slump (in.) 3.5 7-day average 6,620
Air Content (%) 28-day 8,560 8.72 149.88
Batch Weight (lb/yd3) 3981 28-day 8,640 8.68 149.20
Unit Weight (lb/ft3) 149.0 28-day 8,560 8.74 150.23
Concrete Temp (°F) 62 28-day average 8,590
Maurika L. Lake David A. Breitfeller, PE
Laboratory Manager Project Engineer
CTL Engineering, Inc.
Respectfully Submitted,
SAMPLES AND MATERIAL DATA SUPPLIED BY CLIENT
REPORT ON SAMPLE OF CONCRETE MIX TRIAL BATCH
Mix Design Batching Data
Type
Hardened Concrete Properties, 4" x 8" Cylinders
ASTM C 494 Type C
Brand Name
ASTM C 494 Type A/F HRWR
Euclid WR81ASTM C 494 Type A
ASTM C 260
As Received
Weight (lb)
Density
(lb/ft3)
Compressive
Strength (psi)
Fresh Concrete Properties
ASTM C 494 Type D
Offices: Ohio, Indiana, West Virginia
The Euclid Chemical Company19218 Redwood Rd. • Cleveland, OH 44110Phone: [216] 531-9222 • Toll-free: [800] 321-7628 • Fax: [216] 531-9596www.euclidchemical.com
ACCELG
UA
RD
® 80
ACCELGUARD® 80Non-chloride, Accelerating & Water Reducing Admixture
DescriptionACCELGUARD 80 is an accelerating and water reducing admixture for concrete that does not contain calcium chloride. It improves properties of plastic and hardened concrete, provides a significant improvement in early stiffening and setting characteristics, improved workability and decreased bleeding and segregation. This admixture is compatible with air-entraining admixtures, HRWR admixtures (super plasticizers), and conventional water reducing admixtures. ACCELGUARD 80 is effective at all temperatures but is particularly effective above 50°F (10°C).
Primary Applications• Cold weather concreting• Structural and plain concrete
• Concrete block and mortar• Precast and post tensioned concrete
Features/Benefits• Reduces initial set 1 to 4 hours depending on concrete temperatures• Improves workability and provides denser concrete• Minimizes bleeding and segregation• Improves compressive strength development at early ages• Decreases overtime allowing earlier finishing• Increases protection for reinforcement in concrete
Technical Information
Perfomance Data
The following test results were achieved using typical ASTM C 494 mix design requirements, 517 lb/yd3 (307 kg/m3) cement content and similar (± 0.5)% air content.
These results were obtained under laboratory conditions with materials and mix designs meeting the specifications of ASTM C 494. Changes in materials and mix designs can affect the dosage response of ACCELGUARD 80.
Master Form
at #:03 3000 03 4000
ACCELERATO
RS
WARRANTY: The Euclid Chemical Company (“Euclid”) solely and expressly warrants that its products shall be free from defects in materials and workmanship for one (1) year from the date of purchase. Unless authorized in writing by an officer of Euclid, no other representations or statements made by Euclid or its representatives, in writing or orally, shall alter this warranty. EUCLID MAKES NO WARRANTIES, IMPLIED OR OTHERWISE, AS TO THE MERCHANTABILITY OR FITNESS FOR ORDINARY OR PARTICULAR PURPOSES OF ITS PRODUCTS AND EXCLUDES THE SAME. If any Euclid product fails to conform with this warranty, Euclid will replace the product at no cost to Buyer. Replacement of any product shall be the sole and exclusive remedy available and buyer shall have no claim for incidental or consequential damages. Any warranty claim must be made within one (1) year from the date of the claimed breach. Euclid does not authorize anyone on its behalf to make any written or oral statements which in any way alter Euclid’s installation information or instructions in its product literature or on its packaging labels. Any installation of Euclid products which fails to conform with such installation information or instructions shall void this warranty. Product demonstrations, if any, are done for illustrative purposes only and do not constitute a warranty or warranty alteration of any kind. Buyer shall be solely responsible for determining the suitability of Euclid’s products for the Buyer’s intended purposes.
Rev. 7.11
The typical dosage range for ACCELGUARD 80 is 12- 90 oz per 100 lbs (780 - 5870 mL/100kg) of cementitous material. Higher dosages are acceptable with prior testing and confirmation of the desired performance with specific materials being used.
ACCELGUARD 80 should be added to the initial batch water of the concrete mixture. Do not dispense onto dry cement. For ambient temperatures below 50°F (10°C) follow ACI 306 Cold Weather Requirements.
Precautions/Limitations• ACCELGUARD 80 will freeze at temperatures of approximately -15°F (-26°C). Freezing and thawing will not
harm the material if thoroughly agitated. • Do not use air for agitation.• Do not dispense directly onto dry cement.• Do not use ACCELGUARD 80 with modified cements without consulting The Euclid Chemical Company.• Keep concrete from freezing until a minimum of 500 psi (3.5 MPa) is achieved.• In all cases, consult the Material Safety Data Sheet before use.
Directions for use
Specifications/Compliances• Fully complies with ASTM C 494, Type C and E admixture specifications• Fully complies with AASHTO M 194• ACI 201, Guide for Durable Concrete and ACI 302 Guide for Concrete Floor and Slab Construction prohibit the
use of chlorides in many types of concrete. ACCELGUARD 80 may be used in these types of concrete such as, floors over prestressed concrete or galvanized decking, floors containing two kinds of embedded metal, reinforced concrete in moist environments and/or exposed to chloride deicing salts
• ANSI/NSF STD 61 registered
Shelf Life2 years in original, unopened package.
PackagingACCELGUARD 80 is packaged in bulk, 275 gal (1041 L) totes, 55 gal (208 L) drums and 5 gal (18.9 L) pails.
Accurate Concrete Systems Inc. Project : Westlake High School
37152 Sugar Ridge Rd. Westlake
North Ridgeville, OH 44039
Re : Mix Designs
3000 n/a Concrete .45 w/c Slab on Grade Source
440 Lbs. Cement type I St. Marys
110 Lbs. Type "F" Fly Ash Headwaters
1785 Lbs. # 8 Limestone Hanson
1435 Lbs. Concrete Sand Brugman
247 Lbs. Water Potable
4 oz/cwt WR 91 Euclid
14 oz/cwt Barrier 1 Barrier 1
.45 water cement ratio
3-5" maximum slump
2500 n/a Concrete .45 w/c Slab on Grade Source
400 Lbs. Cement type I St. Marys
80 Lbs. Type "F" Fly Ash Headwaters
1785 Lbs. # 8 Limestone Hanson
1465 Lbs. Concrete Sand Brugman
211 Lbs. Water Potable
4 oz/cwt WR 91 Euclid
14 oz/cwt Barrier 1 Barrier 1
.45 water cement ratio
3-5" maximum slump
Westview Concrete requests copies of test results for
monitoring and verification of concrete mixes
Westview Concrete Corporation
26000 Sprague Road
Olmsted Falls, OH 44138
440-235-1806 (fax) 440-235-1893
March 26, 2012
Westlake High School
Product Data Sheet Manufacturer:
Barrier-1 Inc 1901 Tumblewater Blvd. Ocoee, Florida 34761 Ph: 877.224.5850 Fax: 866.594.3490 Email: [email protected] Website: www.barrier-1.com Product Description:
Barrier-1 is a very unique, complex formula that is free of all volatile organic compounds (VOC). It is specifically designed to have a natural chemical reaction with pre-existing elements inside the concrete to eliminate the route of moisture vapor emission through concrete by closing down the integral capillary system. The chemical reaction forms a permanent barrier (capillary break) which will become integral to the concrete and irremovable. Barrier-1 is a high performance concrete admixture. As such, it is integral to the concrete and will not interfere with the bonding of adhesives, resinous coatings or cementitious underlayments or levelers. Advantages:
By closing down the capillary system, hydration is uniform resulting in: higher density, higher strength, abrasion resistance, reduced slab warping, and concrete that is virtually impermeable. Technical Data:
Appearance: Colorless Odor: None Toxicity: None Flammability: None Ph: 11.3 Specific gravity: 1.17 Shelf Life: Indefinite Weight: 11.2 lbs per gallon Freeze Temp: 32°F Storage Temp: above 36°F Solvent: Water Acid Resistance: Excellent Hazardous Vapors: None Capillary Break: Calcium Silicate Hydrate Installation: All concrete Environmental Considerations:
Barrier-1 is environmentally safe and contains no VOCs. Further, Barrier-1 contains an anti-microbial biocide to inhibit mold and bacteria growth. Dispensing:
Barrier-1 is added at a rate of 14oz per 100 lbs. of total cementitious materials, at the tail end of the load and should be dosed within plus or minus 3%. Additional dosage may be required based on the mix design. Due to ease and accuracy of dosing, it is recommended that Barrier-1 be added at the batch plant; however, it can be added directly at the jobsite. If this is done, let drum rotate for 7 minutes before discharge.
Concrete Performance:
- Barrier-1 High Performance Concrete Admixture is not an accelerator or a retarder - It has little to no impact on set times - It has minimal impact on slump (not more than 0.5” loss) - May be used with all other admixtures with the exception of shrink reducing admixes (SRA) provided that such admixtures are added separately and the combination has no deleterious effect on the concrete - A water-to-cementitious material ratio (w/cm) of 0.42 to 0.52 is critical and it is imperative to comply with the mix design - Barrier-1 is used in lieu of that portion of the mix water, not in addition to the mix water (1 for 1 replacement) - Use of water reducing admixes is recommended to achieve slumps greater than 4” - With Barrier-1 there is reduced bleed water, creating a richer, creamier, undiluted paste and therefore facilitating finishing operations Curing:
For slabs to receive moisture sensitive flooring, Barrier-1 concurs with the recommendation of ACI 302.2R; “such slabs should be cured by being covered with waterproof paper, plastic sheets, or a combination of the two for 3 to 7 days”. However, a Barrier-1 dosed slab requires only 24 hours of curing by this method. Curing compounds may be used (with an understanding of their potential affect on subsequent flooring) and have no deleterious effects on the performance of Barrier-1 Additional Requirements:
A representative or agent of Barrier-1 manufacturer must be present at the jobsite during placement of all treated concrete. Do not proceed without this representative being present for certification. An Agent Of Barrier-1 Shall, In Most Instances, Be An Independent Concrete Inspection Company. This Inspection Company Will Provide Barrier-1 With Cylinders From Every Placement Of Concrete For Hydraulic Conductivity/Coefficient of Permeability Testing. These Tests are for Barrier-1’s Internal Quality Control and Warranty Purposes.
By conducting such rigorous testing on every day of placement, Barrier-1 is in full compliance with ASTM F710 mandate of testing every slab for moisture. Warranty:
Barrier-1 is formulated to eliminate the route of moisture vapor emission through concrete and meets or exceeds all guidelines pertaining to moisture emission as established by the flooring industry. This admixture carries a standard manufacturer’s warranty for ten (10) years against moisture vapor emission flooring failures, including all finish floor materials and labor. Contact manufacturer for more information on warranty condition, duration and remedies. Technical Services:
For technical assistance, contact your Barrier-1 Regional Manager indicating your state when you call. Phone: 877.224.5850 Email: [email protected] Fax: 866.594.3490 Website: www.barrier-1.com
Ph: 877.224.5850 Fax: 866.594.3490
Email: [email protected] Website: www.barrier-1.com 1901 Tumblewater Blvd. Ocoee, Florida 34761