300
by knürr www.knuerr.com ENVIRONMENTS FOR ELECTRONICS Electronic Systems Electronic Systems Order Information System Order Information System

Shkaf Knurr Electronics e

Embed Size (px)

Citation preview

Page 1: Shkaf Knurr Electronics e

by knürrwww.knuerr.com

E N V I R O N M E N T S F O R E L E C T R O N I C S

ElectronicSystemsElectronicSystems

Order InformationSystemOrder InformationSystem

Dokument 1 20.09.2002 11:02 Uhr Seite 1

Page 2: Shkaf Knurr Electronics e

Dokument 2 20.09.2002 11:31 Uhr Seite 1

Page 3: Shkaf Knurr Electronics e

by knürrwww.knuerr.com

E N V I R O N M E N T S F O R E L E C T R O N I C S

• Complete standardproduct portfolio- innovative, modular and flexible- high availability- for growing markets

• Customer Solutions- complete preconfigured

solutions for OEM customersbased on platform products

• Global player- worldwide ressources for

engineering, productionand logistics

• Integrated Quality andEnvironmental ManagementSystem according to- DIN EN ISO 9001 / 14001

8 Seiten_englisch_sp 20.09.2002 10:47 Uhr Seite 1

Page 4: Shkaf Knurr Electronics e

Colocation racksmiracel indoor racks

Perfect cable managementmiracel indoor racks

Server racksas individual as ourcustomers:miracel indoor racks

Computer centremiracel server racks

8 Seiten_englisch_sp 20.09.2002 10:48 Uhr Seite 2

Page 5: Shkaf Knurr Electronics e

by knürrE N V I R O N M E N T S F O R E L E C T R O N I C S

smaract2

Highly integratableCompact rack

conactThe accepted

19” wall enclosure

doubleprorackThe versatile

19” enclosure

tecoras - ETSIndoor rackfor BTS use

8 Seiten_englisch_sp 20.09.2002 10:48 Uhr Seite 3

Page 6: Shkaf Knurr Electronics e

tecorascomplete productrange for Telecom

Indoor rackMobilecommunicationbase station

Final controlPerformance tests on ETS racks atthe company’s own test shop

In-house proceduresreplicate current national and interna-tional certification standard

tecorasOutdoor cabinet for UMTS use

8 Seiten_englisch_sp 20.09.2002 10:48 Uhr Seite 4

Page 7: Shkaf Knurr Electronics e

by knürrE N V I R O N M E N T S F O R E L E C T R O N I C S

cs200719” chassis for heavyequipment

chasseleon19” chassis

micadoThe versatile19” desktop enclosure

primus19” modular chassis

8 Seiten_englisch_sp 20.09.2002 10:48 Uhr Seite 5

Page 8: Shkaf Knurr Electronics e

CPCIElectronic integrationand bus systems

UPSuninteruptablepower supply

RAID systemsby knürr

8 Seiten_englisch_sp 20.09.2002 10:49 Uhr Seite 6

Page 9: Shkaf Knurr Electronics e

by knürrE N V I R O N M E N T S F O R E L E C T R O N I C S

RMS compactrack monitoring system

IPCIndustrial computersystems

NEW TFTThe new TFT consolewill convince you

8 Seiten_englisch_sp 20.09.2002 10:49 Uhr Seite 7

Page 10: Shkaf Knurr Electronics e

by knürrE N V I R O N M E N T S F O R E L E C T R O N I C S

tecoras - UPSBatteries serve the uninteruptablepower supply

tecoras - DC back-up systemspower supply with AC/DC distribution

dart fan unitair-baffle technologydeveloped by knürr

di-stripSocket stripsfor worldwideapplications

8 Seiten_englisch_sp 20.09.2002 10:49 Uhr Seite 8

Page 11: Shkaf Knurr Electronics e

Order Information SystemKnürr AGElectronic Systems

01-112_eng_final.qxd 07.08.2002 14:50 Uhr Seite 1

Page 12: Shkaf Knurr Electronics e

01-112_eng_final.qxd 07.08.2002 14:50 Uhr Seite 2

Page 13: Shkaf Knurr Electronics e

miracel 19“ Rack, indoor Page 5tecoras ETS Racks Page 33smaract 19“ Compact rack, indoor Page 39doubleprorack Indoor racks Page 47conact 19“ Wall-mounting rack Page 59tecoras Outdoor racks Page 65

Knürr Rack Systems

CS2007 19“ Heavy duty chassis Page 87eurocard 19“ Modular chassis Page 91chasseleon 19“ Bench chassis enclosure Page 97micado 19“ Bench enclosure Page 111primus 19“ Modular chassis Page 123

Knürr Electronic Enclosures

PCI Bus systems Page 145Power packs Page 157

IPC Industrial PC Page 161Raid systems Page 167

UPS Uninterruptible power supply Page 171KVM Console switches Page 185RMS Monitoring systems Page 191TFT Keyboards, displays Page 197

Knürr Electronic Integration

di-strip Socket strips Page 201tecoras UPS Page 233

Knürr Power Supply Systems

dart Ventilation systems Page 241Cooling systems Page 249Heating systems Page 255

Knürr Climate Systems

Electrical accessories Page 260Mechanical accessories Page 262

Accessories

by knürr

3

CONTENT

01-112_eng_final.qxd 07.08.2002 14:50 Uhr Seite 3

Page 14: Shkaf Knurr Electronics e

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 4

Page 15: Shkaf Knurr Electronics e

Strong Points and technical details Page 6Product Page 8Accessories Page 16

miracel 19“ Rack, Indoor

miracel

by knürr

5

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 5

Page 16: Shkaf Knurr Electronics e

by knürr

6

Forward-thinkingFlexibility and security for thefuture by integrating 19” andmetric technology.

Modular constructionIncludes easy mounting of allnon-standard electronic installa-tions - variable and at integrated19” or 25 mm increments.

EMC ConceptsRefined solutions guarantee optimal EMC protection rating.

Can be extended at any timeSystem extensions can be easilyimplemented while retaining theEMC screening and IP protectionrating.

Cable managementGuaranteed orderly and space-saving cable routing.Adaption to the installation site,cable routing selectable with anextensive range of accessorycomponents.

Flexible ventilation componentsAlways the best ventilation soluti-on with the corresponding choiceof accessory components. In thisway, by utilising perforated bot-tom covers, top covers and doors,the airflow can be specificallyadapted to the installed compo-nents.

6

5

4

3

2

1

miracelStrong points

MIR00005_E1

MIR00139_E2

MIR00329_E3

TEC00440_E3

TEC00028_E4

MIR00191_E5

MIR00406_E6

MIR00407_E6

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 6

Page 17: Shkaf Knurr Electronics e

by knürr

7

MIR00056_E

Material- Extruded aluminium- Corner piece, die-cast

aluminium- Covers, sheet steel, zinc passi-

vated- Doors, sheet steel or with

single safety glass panel, ope-ning angle 180º

Installation dimensions in accordance with IEC 297-3 and IEC 917- Height: 23 HU / 37 HU / 41 HU /

46 HU(1 HU (or 1U) = 44.45 mm)66 Module / 74 module / 82module (1 module = 25 mm)

- Width: 482.6 mm (19“ design),535 mm (20 module design)

Space solution- 82% of the surface area as

useable surface for installationand cable routing

- Cross-connecting (jumpering)space, front 123 mm, and 73 mm

Configuration- Stationary, on levelling feet- Stationary with plinth- Mobile with plinth and lock

Finish / Colour- Basic rack, polished- Door trim, black, RAL 9011- Visible cover surfaces, powder-

coated, light-grey RAL 7035

NoteAdditional colours on request!

Static load rating- 5000 N With stationary model- 3000 N With mobile model

Heat transfer Dissipation power with- Closed cover, up to

500 W- Vent lid, up to 700 W

Tests according to the model- Vibration test in accordance

with MIL-STD 810 E- IP Test in accordance with IEC

529- UL Test 1244- NEMA 12 Standard- EMC Shielding attenuation in

accordance with MIL-STD 285(10 MHz - 30 MHz) and VG 95 373 part 15 (30 MHZ-1GHz)

- Vibrations and shock test inaccordance with ETS 300 019

- Seismic test, Bellcore (NEBS)TR-NWT 000063 zone 4

- Earth continuity, VDE 0 100 T540

Additional standards and tests onrequest.

Rack suitesTo set up a rack suite with anumber of racks (n) you require- all racks (n) minus 1 without

side panels and one rack withside panels

- in a rack suite, per connection,you require one set of rackconnectors

miracel 19“ RackTechnical data

MIR00300_E

MIR00300_E

MIR00300c_E

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 7

Page 18: Shkaf Knurr Electronics e

by knürr

8

MIR00043a_E

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depth / Chassis depth, HU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

miracel Lab Rack NO 19With T-slot extrusion, width 600 / 700 / 800W H D HU/U h d kg Model Order no. UP Price600 1200 600 23 1052 435 14 01.135.793.3 1 unit600 1800 600 37 1652 435 16 01.135.795.3 1 unit600 2000 600 41 1852 435 17 01.135.796.3 1 unit600 2200 600 46 2052 435 18 01.135.797.3 1 unit600 1200 800 23 1052 635 16 01.135.817.3 1 unit600 1800 800 37 1652 635 18 01.135.819.3 1 unit600 2000 800 41 1852 635 19 01.135.820.3 1 unit600 2200 800 46 2052 635 20 01.135.821.3 1 unit

700 1200 600 23 1052 435 15 01.135.799.3 1 unit700 1800 600 37 1652 435 17 01.135.801.3 1 unit700 2000 600 41 1852 435 18 01.135.802.3 1 unit700 2200 600 46 2052 435 19 01.135.803.3 1 unit700 1200 800 23 1052 635 17 01.135.823.3 1 unit700 1800 800 37 1652 635 19 01.135.825.3 1 unit700 2000 800 41 1852 635 20 01.135.826.3 1 unit700 2200 800 46 2052 635 21 01.135.827.3 1 unit

800 1200 600 23 1052 435 16 01.135.805.3 1 unit800 1800 600 37 1652 435 18 01.135.807.3 1 unit800 2000 600 41 1852 435 19 01.135.808.3 1 unit800 2200 600 46 2052 435 20 01.135.809.3 1 unit800 1200 800 23 1052 635 18 01.135.829.3 1 unit800 1800 800 37 1652 635 20 01.135.831.3 1 unit800 2000 800 41 1852 635 21 01.135.832.3 1 unit800 2200 800 46 2052 635 22 01.135.833.3 1 unit

Distribution Rack NS 19.6Width 600, with glass doors at frontW H D HU/U h d kg Model Order no. UP Price600 1320 600 23 1052 435 72 with side panel 01.135.109.1 1 unit600 1920 600 37 1652 435 95 with side panel 01.135.111.1 1 unit600 2120 600 41 1852 435 103 with side panel 01.135.112.1 1 unit600 2320 600 46 2052 435 112 with side panel 01.135.113.1 1 unit600 1320 800 23 1052 635 74 with side panel 01.135.127.1 1 unit600 1920 800 37 1652 635 102 with side panel 01.135.129.1 1 unit600 2120 800 41 1852 635 110 with side panel 01.135.130.1 1 unit600 2320 800 46 2052 635 119 with side panel 01.135.131.1 1 unit

600 1320 600 23 1052 435 68 without side panel 01.135.115.1 1 unit600 1920 600 37 1652 435 94 without side panel 01.135.117.1 1 unit600 2120 600 41 1852 435 99 without side panel 01.135.118.1 1 unit600 2320 600 46 2052 435 106 without side panel 01.135.119.1 1 unit600 1320 800 23 1052 635 68 without side panel 01.135.133.1 1 unit600 1920 800 37 1652 635 94 without side panel 01.135.135.1 1 unit600 2120 800 41 1852 635 99 without side panel 01.135.136.1 1 unit600 2320 800 46 2052 635 106 without side panel 01.135.137.1 1 unit

Supply schedule1 Basic rack2 19” Aluminium vertical extrusions with

T-slot and increment slide for springnut M5

2 Multifunctional struts for cable clam-ping and universal mounting options

4 Levelling feet (0-25 mm)

MIR00041_E

MIR00056_E

MIR00031_E

Supply schedule1 Basic rack2 19“ Aluminium vertical extrusions with

T-slot and increment slide for springnut M5

2 Multifunctional struts for cable clam-ping and universal mounting options

1 Top cover with vent lid and integrated cable routing

1 Front single door, single safety glasspanel, with handle and fixing for cylin-der lock

1 Rear single door, sheet steel, withhandle and fixing for cylinder lock

2 Side panels with quick-release fastener(depending on the model)

1 Plinth for cable routing, side and rear,with levelling feet (0-25 mm)

2 Side plinth trims, closed (as per model)2 Plinth trims for front and rear side, with

ventilation slots and fixing for filter mat1 Earth set, complete (VDE 0100)

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 8

Page 19: Shkaf Knurr Electronics e

by knürr

9

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depth / Chassis depth, HU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

miracel 19“ Distribution Rack NS 19.8Width 800, glass door at frontW H D HU/U h d kg Model Order no. UP Price800 1320 600 23 1052 435 78 glass door, with sides 01.135.001.1 1 unit800 1920 600 37 1652 435 103 glass door, with sides 01.135.003.1 1 unit800 2120 600 41 1852 435 112 glass door, with sides. 01.135.004.1 1 unit800 2320 600 46 2052 435 121 glass door, with sides 01.135.005.1 1 unit800 1320 800 23 1052 635 80 glass door, with sides. 01.135.019.1 1 unit800 1920 800 37 1652 635 111 glass door, with sides. 01.135.021.1 1 unit800 2120 800 41 1852 635 120 glass door, with sides 01.135.022.1 1 unit800 2320 800 46 2052 635 129 glass door, with sides 01.135.023.1 1 unit

800 1320 600 23 1052 435 70 glass door, no sides 01.135.007.1 1 unit800 1920 600 37 1652 435 95 glass door, no sides 01.135.009.1 1 unit800 2120 600 41 1852 435 103 glass door, no sides 01.135.010.1 1 unit800 2320 600 46 2052 435 112 glass door, no sides 01.135.011.1 1 unit

800 1320 800 23 1052 635 73 glass door, no sides 01.135.025.1 1 unit800 1920 800 37 1652 635 101 glass door, no sides 01.135.027.1 1 unit800 2120 800 41 1852 635 109 glass door, no sides 01.135.028.1 1 unit800 2320 800 46 2052 635 118 glass door, no sides 01.135.029.1 1 unit

800 1320 800 23 1052 635 80 double glass door, sides 01.135.037.1 1 unit800 1920 800 37 1652 635 111 double glass door, sides 01.135.039.1 1 unit800 2120 800 41 1852 635 120 double glass door, sides 01.135.040.1 1 unit800 2320 800 46 2052 635 121 double glass door, sides 01.135.041.1 1 unit

800 1320 800 23 1052 635 73 double glass door, no sides 01.135.043.1 1 unit800 1920 800 37 1652 635 101 double glass door, no sides 01.135.045.1 1 unit800 2120 800 41 1852 635 109 double glass door, no sides 01.135.046.1 1 unit800 2320 800 46 2052 635 118 double glass door, no sides 01.135.047.1 1 unit

Supply schedule1 Basic rack2 19“ Aluminium vertical extrusions with

T-slot and increment slide for springnut M5

2 Multifunctional struts for cable clam-ping and universal mounting options

1 Top cover with vent lid and integratedcable routing

1 Front door, single or double door, singlesafety glass panel, with handle andfixing for cylinder lock

1 Rear door, single or double door, sheetsteel, with handle and fixing for cylinderlock

2 Side panels with quick-release fastener(depending on the model)

1 Plinth for cable routing, side and rear,with levelling feet (0-25 mm)

2 Side plinth trims, closed (depending onthe model)

2 Plinth trims for front and rear side, withventilation slots and fixing for filter mat

1 Earth set, complete (VDE 0100)

MIR00419_E

MIR00469_E

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 9

Page 20: Shkaf Knurr Electronics e

by knürr

10

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

miracel 19“ Distribution Rack NS 25Width 800, glass door at frontW H D HU/U h d kg Model Order no. UP Price800 2120 600 41 1852 365 112 with sides 01.136.044.1 1 unit800 2120 800 41 1852 565 120 with sides 01.136.050.1 1 unit800 2320 800 46 2052 565 130 with sides 01.136.051.1 1 unit800 2120 900 41 1852 665 124 with sides 01.136.056.1 1 unit800 2320 900 46 2052 665 134 with sides 01.136.057.1 1 unit800 2120 600 41 1852 365 103 without sides 01.136.244.1 1 unit800 2120 800 41 1852 565 109 without sides 01.136.250.1 1 unit800 2120 900 41 1852 665 130 without sides 01.136.256.1 1 unit

Supply schedule1 Basic rack4 19“ Aluminium vertical extrusions with

T-slot and increment slide for springnut M5

2 Multifunctional struts for cable clam-ping and universal mounting options

2 Side panels with quick-release fastener1 Cover with vent lid and integrated cable

routing1 Front single door, single safety glass

panel, with handle and fixing for cylin-der lock

1 Rear single door, sheet steel, withhandle and fixing for cylinder lock

1 Plinth for cable routing, side and rear,with levelling feet (0-25 mm)

2 Plinth trims for front and rear side, withventilation slots and fixing for filter mat

2 Plinth trims, closed1 Earth set, complete (VDE 0100)

Supply schedule1 Basic rack1 19“ Swing frame with mounting holes

for spring nut M52 Multifunctional struts for cable clam-

ping and universal mounting options2 Side panels with quick-release fastener1 Cover with vent lid and integrated cable

routing1 Front door with handle and fixing for

cylinder lock

1 Rear panel with quick-release fastener1 Plinth for cable routing, side and rear,

with levelling feet (0-25 mm)2 Plinth trims for front and rear sides,

with ventilation slots and fixing for filtermat

2 Plinth trims, closed1 Earth set, complete (VDE 0100)

miracel 19“ Distribution Rack with Swing Frame NS 19.8 DWidth 800, with glass doors, single-winged, frontW H D HU/U h d kg Model Order no. UP Price800 1320 600 20 892.7 435 77 with sides 01.135.271.1 1 unit800 1920 600 33 1470.5 435 102 with sides 01.135.273.1 1 unit800 2120 600 38 1692.8 435 111 with sides 01.135.274.1 1 unit800 2320 600 42 1870.6 435 120 with sides 01.135.275.1 1 unit

800 1320 800 20 892.7 635 79 with sides 01.135.289.1 1 unit800 1920 800 33 1470.5 635 110 with sides 01.135.291.1 1 unit800 2120 800 38 1692.8 635 119 with sides 01.135.292.1 1 unit800 2320 800 42 1870.6 635 128 with sides 01.135.293.1 1 unit

800 1320 600 20 892.7 435 69 without sides 01.135.277.1 1 unit800 1920 600 33 1470.5 435 94 without sides 01.135.279.1 1 unit800 2120 600 38 1692.8 435 102 without sides 01.135.280.1 1 unit800 2320 600 42 1870.6 435 111 without sides 01.135.281.1 1 unit

800 1320 800 20 892.7 635 72 without sides 01.135.295.1 1 unit800 1920 800 33 1470.5 635 100 without sides 01.135.297.1 1 unit800 2120 800 38 1692.8 635 108 without sides 01.135.298.1 1 unit800 2320 800 42 1870.6 635 117 without sides 01.135.299.1 1 unit

MIR00536_E

MIR00047_E

MIR00470_E

MIR00472_E

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 10

Page 21: Shkaf Knurr Electronics e

by knürr

11

MIR00505_E

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

miracel Network Equipment Rack NG 800Width 800, with glass door, single-wingedW H D HU/U h d kg Model Order no. UP Price800 1320 800 23 1052 730 77 with side panel 01.135.649.1 1 unit800 1920 800 37 1652 730 107 with side panel 01.135.651.1 1 unit800 2120 800 41 1852 730 115 with side panel 01.135.652.1 1 unit800 2320 800 46 2052 730 124 with side panel 01.135.653.1 1 unit

800 1320 800 23 1052 730 70 without side panel 01.135.655.1 1 unit800 1920 800 37 1652 730 97 without side panel 01.135.657.1 1 unit800 2120 800 41 1852 730 104 without side panel 01.135.658.1 1 unit800 2320 800 46 2052 730 113 without side panel 01.135.659.1 1 unit

Supply schedule1 Basic rack2 Multifunctional struts for cable clam-

ping and universal mounting options2 Side panels with quick-release fastener1 Top cover with vent lid and integrated

cable routing1 Front single door, single safety glass

panel, with handle and fixing for cylin-der lock

1 Rear single door, sheet steel, withhandle and fixing for cylinder lock

1 Plinth for cable routing, side and rear,with levelling feet (0-25 mm)

2 Plinth trims for front and rear side, withventilation slots and fixing for filter mat

2 Side plinth trims, closed1 Earth set, complete (VDE 0100)

miracel 19“ Server RackWidth 600, mobile, glass door at frontW H D HU/U h d kg Model Order no. UP Price600 1300 900 23 1052 740 72 01.132.031.1 1 unit600 2100 900 41 1852 740 120 01.132.033.1 1 unit

Supply schedule1 Basic rack4 19“ Mounting extrusions 2 Side panels with quick release fasteners 1 Top cover closed; with 23 HU version,

reinforced for monitor1 Front door with single safety glass

panel, flow cross-section23 HU 1000 cm2, 41 HU 1500 cm 2

Air throughput (with a flow speed of3m/sec); 23 HU, 1080 m3/h, 41 HU, 1620m3/h

1 Rear door, sheet steel with perforations,large air outlet cross-section

1 Mobile plinth with cable entry and level-ling feet

1 Earth set, complete1 Lock set, complete

MIR00039_E

MIR00497_E

MIR00505_E

MIR00053a_E

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 11

Page 22: Shkaf Knurr Electronics e

by knürr

12

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

miracel 19“ Server RackWidth 700, glass door at frontW H D HU/U h d kg Model Order no. UP Price700 2100 900 41 1852 740 124 01.132.043.1 1 unit700 2300 900 46 2052 740 133 01.132.044.1 1 unit

Supply schedule1 Basic rack4 19’’ Sheet steel mounting hole vertical

extrusions2 Side panels1 Cover, closed1 Front door with single safety glass panel

and openings for air intake1 Rear door with large area perforation

1 Mobile plinth with rear cable entry andlevelling feet

6 Cable trays with swivel arm(7 with 46 HU)

4 19’’ Support brackets, 2 HU (5 with 46HU)(BN 01.132.053.9)

2 19’’ Support brackets, 3 HU (2 with 46HU)(BN 01.132.054.9)

1 Earth set, complete

Trim for 19“ Vertical Installation 3 x 2 HU/UW H W HU/U h d kg Model Order no. UP Price

41 left 01.132.048.1 1 unit46 left 01.132.049.1 1 unit

MaterialSheet steel 1.5 mm

FinishRAL 7035 Powder-coated

InstallationCan be mounted on the left rack side19” Installation, vertical, 3 x 2 HU/UMax. depth of the installation compo-nents, 300 mm (only for use in serverracks BN 01.132.043.1 / 01.132.044.1)

Supply schedule1 TrimMounting material

Cable TrayW H D HU/U h d kg Model Order no. UP Price

01.132.050.9 1 unitwith swivel arm 01.132.051.9 1 unit

- For storing light-weight electronic equip-ment (max. 5 kg)

- For orderly storage of cable excess - Only for installation in server racks BN

01.132.043.1 / 01.132.044.1

Supply schedule1 Support boardMounting material

miracel 19“ ASP Rack / 19“ Server RackWidth 600, front door with perforationW H D HU/U h d kg Model Order no. UP Price600 2000 900 41 1852 740 01.127.933.1 1 unit600 2200 900 46 2052 740 01.127.934.1 1 unit600 2000 900 41 1852 740 with electr. locking 01.127.940.1 1 unit

- Order plinth optionally- ASP Rack 41 HU

With electric locking, also included: key-pad, power pack and di - strip socketstrips (5-way)

- Additional dimensions are available onrequest

Supply schedule1 Basic rack4 19’’ Server, sheet steel, mounting hole

extrusions2 Doors, perforated (air throughput 52%)2 Side panels1 Cover, closed1 Earth set, complete1 Locking set, completeMIR20016_E

MIR80001_E

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 12

Page 23: Shkaf Knurr Electronics e

by knürr

13

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

Mounting Adapter for 19“ Server ExtrusionFor ASP rack and ISP rackW H D HU/U h d kg Model Order no. UP Price

01.127.119.9 1 unit

- For mounting standard Knürr accessories(storage shelves, drawers, chassis runners,keyboard runners etc.) in the 19’’ installati-on area

MaterialZinc passivated sheet steel

Supply schedule4 Adapters

miracel ISP RackW H D HU/U h d kg Model Order no. UP Price700 2000 900 2 separate compartments 01.127.901.1 1 unit700 2000 900 3 separate compartments 01.127.900.1 1 unit

Suppy schedule1 Basic rack8 19” Server sheet steel mounting hole

extrusions (2 separate compartments)12 19” Server sheet steel mounting hole

extrusions (3 separate compartments)16 Mounting brackets, 19” server extrusi-

on (2 separate compartments)24 Mounting brackets, 19” server extrusi-

on (3 separate compartments)4 Doors, perforated (air throughput 52%)

with lock (2 separate compartments)6 Doors, perforated (air throughput 52%)

with lock (3 separate compartments)4 Frame trims2 Side panels1 Cover, closed2 Horizontal bases (2 separate compart-

ments)3 Horizontal bases (3 separate compart-

ments)8 Universal depth struts (2 separate com-

partments)12 Universal depth struts (3 separate

compartments

ISP Rack Partition PanelW H D HU/U h d kg Model Order no. UP Price

ISP with 2 separate compartments 01.127.157.9 1 unitISP with 3 separate compartments 01.127.156.9 1 unit

- For safe partitioning of the separate com-partments, vertical, can be mounted laterwhen adding-on racks

- Individual, that is, for each compartment,can be separately opened via quick-releasefastener

Material / FinishSheet steel zinc passivated 1 mm

Supply schedule2 Partition panels (for ISP rack with 2

separate compartments)3 Partition panels (for ISP rack with 3

separate compartments)Mounting material

ISP Rack ConnectorW H D HU/U h d kg Model Order no. UP Price

01.127.114.9 1 unit

MaterialSheet steel 1mm,zinc passivated

Supply schedule8 Mounting strapsMounting material

MIR20021_E

MIR80050_E

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 13

Page 24: Shkaf Knurr Electronics e

by knürr

14

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

miracel 19“ Basic RackW H D HU/U h d kg Model Order no. UP Price591 1196 585 23 1052 440 13 01.130.190.0 1 unit591 1596 585 32 1452 440 15 01.130.192.0 1 unit591 1796 585 37 1652 440 16 01.130.193.0 1 unit591 1996 585 41 1852 440 17 01.130.194.0 1 unit591 2196 585 46 2052 440 18 01.130.195.0 1 unit

591 1196 785 23 1052 640 14 01.130.280.0 1 unit591 1596 785 32 1452 640 16 01.130.282.0 1 unit591 1796 785 37 1652 640 17 01.130.283.0 1 unit591 1996 785 41 1852 640 18 01.130.284.0 1 unit591 2196 785 46 2052 640 19 01.130.285.0 1 unit

791 1196 585 23 1052 440 14 01.130.226.0 1 unit791 1596 585 32 1452 440 16 01.130.228.0 1 unit791 1796 585 37 1652 440 17 01.130.229.0 1 unit791 1996 585 41 1852 440 18 01.130.230.0 1 unit791 2196 585 46 2052 440 19 01.130.231.0 1 unit

791 1196 785 23 1052 640 15 01.130.316.0 1 unit791 1596 785 32 1452 640 17 01.130.318.0 1 unit791 1796 785 37 1652 640 18 01.130.319.0 1 unit791 1996 785 41 1852 640 19 01.130.320.0 1 unit791 2196 785 46 2052 640 22 01.130.321.0 1 unit

Supply schedule1 Basic rack4 19“ Angular extrusions with mounting

holes, sheet steel4 Adjustable feet (0-25 mm)MIR00300_E

MIR00196_E

MIR00466_E

MIR00301a_E

miracel 19“ RackWithout doors, B 600 mmW H D HU/U h d kg Model Order no. UP Price600 1200 600 23 1052 440 42 01.131.068.1 1 unit600 1600 600 32 1452 440 52 01.131.070.1 1 unit600 1800 600 37 1652 440 57 01.131.071.1 1 unit600 2000 600 41 1852 440 62 01.131.072.1 1 unit600 2200 600 46 2052 440 66 01.131.073.1 1 unit

600 1200 800 23 1052 640 48 01.131.074.1 1 unit600 1600 800 32 1452 640 58 01.131.076.1 1 unit600 1800 800 37 1652 640 63 01.131.077.1 1 unit600 2000 800 41 1852 640 69 01.131.078.1 1 unit600 2200 800 46 2052 640 75 01.131.079.1 1 unit

Supply schedule1 Basic rack4 19“ Angular extrusions with mounting

holes, sheet steel2 Side panels with quick-release

fasteners1 Top cover, closed1 Rear panel with quick-release fasteners 2 Horizontal trim extrusions, front2 Vertical trim extrusions, front 4 Adjustable feet (0-25 mm)

MIR00300c_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 14

Page 25: Shkaf Knurr Electronics e

by knürr

15

MIR00329_E

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

miracel 19“ Rack IP 55With front glass doorW H D HU/U h d kg Model Order no. UP Price600 1200 600 23 1052 440 55 01.132.268.1 1 unit600 1600 600 32 1452 440 69 01.132.270.1 1 unit600 1800 600 37 1652 440 75 01.132.271.1 1 unit600 2000 600 41 1852 440 80 01.132.272.1 1 unit600 2200 600 46 2052 440 86 01.132.273.1 1 unit

600 1200 800 23 1052 640 65 01.132.274.1 1 unit600 1600 800 32 1452 640 76 01.132.276.1 1 unit600 1800 800 37 1652 640 83 01.132.277.1 1 unit600 2000 800 41 1852 640 90 01.132.278.1 1 unit600 2200 800 46 2052 640 96 01.132.279.1 1 unit

Supply schedule1 Basic rack4 19“ Angular extrusions with mounting

holes, sheet steel2 Side panels with quick-release

fasteners, IP 551 Top cover, closed, IP 551 Bottom cover, IP 551 Rear panel with quick-release

fasteners, IP 55 1 Front door, single security glass panel,

with handle and fixing for cylinder lock,IP 55

4 Adjustable feet (0-25 mm)

miracel 19“ Rack EMCDouble-panelled EMC conceptW H D HU/U h d kg Model Order no. UP Price600 1800 800 37 1652 640 133 01.134.059.1 1 unit600 2000 800 41 1852 640 145 01.134.060.1 1 unit600 2200 800 46 2052 640 154 01.134.061.1 1 unit

Supply schedule1 Basic rack, EMC, yellow chrome-plated1 Front door, EMC, sheet steel with

handle and fixing for cylinder lock1 Rear panel, EMC, sheet steel2 Side panels, EMC with quick-release

fastener1 Top cover, EMC, closed1 Bottom cover, EMC, closed4 19’’ Angular extrusions with mounting

holes, sheet steel4 Adjustable feet (0-25 mm)

MIR00467_E

MIR00301c_E

MIR00449_E

MIR00301c_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 15

Page 26: Shkaf Knurr Electronics e

by knürr

16

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

miracel EMC Panel for Bottom Cover/Top CoverPerforated, with cable entryW H D HU/U h d kg Model Order no. UP Price600 800 01.134.921.0 1 unit

Supply schedule1 EMC Panel, complete4 Distance bolts for top cover

miracel EMC Connection PanelW H D HU/U h d kg Model Order no. UP Price600 400 01.134.800.1 1 unit

- EMC Connection panel, rear, with cableentry

- Compatible shortened EMC sheet steel dooror shortened EMC rear panel are also available on request.

Supply schedule1 Cable entry, complete1 CoverEMC SealsCross-sealingMounting material

MIR00460_E

MIR00459_E

MIR00462_E

MIR00463_E

miracel EMC Fan Installation SetW H D HU/U h d kg Model Order no. UP Price600 800 01.134.961.0 1 unit

- For mounting in the rack upper frame- Use only in conjunction with perforated

EMC panel- For equipping single fans:

Order no. 03.210.245.9

Supply schedule1 Airmatic ventilation unit with

two fans and thermostat2 Cover plates2 Mounting brackets

miracel EMC Panel for Bottom Cover/Top CoverPerforatedW H D HU/U h d kg Model Order no. UP Price600 800 01.134.876.0 1 unit

- For ventilation and air exhaust with convection or in conjunction with the ventilating unit

FinishZinc passivated

Supply schedule1 EMC Panel top/bottom cover, perforated4 Distance bolts for top cover

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 16

Page 27: Shkaf Knurr Electronics e

by knürr

17

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

miracel EMC RackSingle-panelled EMC concept (tecoras-indoor)W H D HU/U h d kg Model Order no. UP Price600 1800 400 37 1652 235 01.171.009.1 1 unit600 1800 600 37 1652 435 01.171.021.1 1 unit600 2000 400 41 1852 245 01.171.010.1 1 unit600 2000 600 41 1852 435 01.171.022.1 1 unit600 2200 400 46 2052 235 01.171.011.1 1 unit600 2200 600 46 2052 435 01.171.023.1 1 unit

- The miracel indoor rack is already EMCshielded in the standard

Supply schedule1 Basic rack2 19’’ Steel extrusions with mounting

holes2 Side panels screwed tight1 Rear panel with quick-release fastener1 Sheet steel door, closed1 Top cover, closed1 Bottom cover, closed4 Levelling feet

EMC Door, PerforatedSingle-panelled EMC concept (tecoras indoor)W H D HU/U h d kg Model Order no. UP Price600 1800 01.171.195.1 1 unit600 2000 01.171.196.1 1 unit600 2200 01.171.197.1 1 unit

Material / FinishSheet steel, zinc passivatedPowder-coated, RAL 7035 textured

Supply schedule1 EMC Door, perforatedMounting material

Double Door EMC, ClosedSingle-panelled EMC concept (tecoras indoor)W H D HU/U h d kg Model Order no. UP Price600 1800 01.171.207.1 1 unit600 2000 01.171.208.1 1 unit600 2200 01.171.209.1 1 unit

Material / FinishSheet steel, zinc passivatedPowder-coated, RAL 7035 textured

Supply schedule1 Door wing, left1 Door wing, rightMounting material

TEC00106_E

TEC00284_E

TEC00283_E

TEC00082_E

TEC00440_ETEC00077_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 17

Page 28: Shkaf Knurr Electronics e

by knürr

18

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Top Cover, EMC, Closed with Cable EntrySingle-panelled EMC concept (tecoras indoor)W H D HU/U h d kg Model Order no. UP Price600 400 01.171.107.1 1 unit600 600 01.171.109.1 1 unit

Material / FinishSheet steel, zinc passivatedPowder-coated, RAL 7035 textured

Supply schedule1 Top cover, closed with cable entryMounting material

TEC00287_E

Top Cover, EMC, PerforatedSingle-panelled EMC concept (tecoras indoor)W H D HU/U h d kg Model Order no. UP Price600 400 01.171.087.1 1 unit600 600 01.171.089.1 1 unit

Material / FinishSheet steel, zinc passivatedPowder-coated, RAL 7035 textured

Supply schedule1 Top cover, perforatedMounting material

TEC00286_E

Top Cover, Perforated with Cable EntrySingle-panelled EMC concept (tecoras indoor)W H D HU/U h d kg Model Order no. UP Price600 400 01.171.117.1 1 unit600 600 01.171.119.1 1 unit

Material / FinishSheet steel, zinc passivatedPowder-coated, RAL 7035 textured

Supply schedule1 Top cover, perforated with cable entryMounting material

TEC00288_E

Bottom Cover, EMC, PerforatedSingle-panelled EMC concept (tecoras indoor)W H D HU/U h d kg Model Order no. UP Price600 400 01.171.261.0 1 unit600 600 01.171.263.0 1 unit

MaterialSheet steel, zinc passivated

Supply schedule1 Bottom cover, perforatedMounting materialTEC00290_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 18

Page 29: Shkaf Knurr Electronics e

by knürr

19

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Bottom Cover, EMC, Closed with Cable EntrySingle-panelled EMC concept (tecoras indoor)W H D HU/U h d kg Model Order no. UP Price600 400 01.171.251.0 1 unit600 600 01.171.253.0 1 unit

MaterialSheet steel, zinc passivated

Supply schedule1 Bottom cover, closed, with cable entryMounting materialTEC00291_E

Bottom Cover, EMC, Perforated with Cable EntrySingle-panelled EMC concept (tecoras indoor)W H W HU/U h d kg Model Order no. UP Price600 400 01.171.271.0 1 unit600 600 01.171.273.0 1 unit

MaterialSheet steel, zinc passivated

Supply schedule1 Bottom cover, perforated, with cable

entryMounting material

TEC00292_E

Rack Connector, EMCSingle-panelled EMC concept (tecoras indoor)W H D HU/U h d kg Model Order no. UP Price

1800 400 01.171.176.1 1 unit1800 600 01.171.178.1 1 unit2000 400 01.171.181.1 1 unit2000 600 01.171.183.1 1 unit2200 400 01.171.186.1 1 unit2200 600 01.171.188.1 1 unit

Material / FinishSheet steel, zinc passivatedPowder-coated, RAL 7035 textured

Supply schedule2 Rack connectors, vertical1 Rack connector below 1 Rack connector aboveMounting material

TEC00282_E

Replacement Filter MatsFor perforated bottom coversW H D HU/U h d kg Model Order no. UP Price400 600 01.171.217.9 1 unit600 600 01.171.219.9 1 unit

- For bottom cover with perforation

MaterialFiledon P 15 / 150

Suppy schedule1 Set of 5 units

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 19

Page 30: Shkaf Knurr Electronics e

by knürr

20

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

miracel Glass DoorW H D HU/U h d kg Model Order no. UP Price600 1200 23 standard door 01.130.600.1 1 unit600 1800 37 standard door 01.130.612.1 1 unit600 2000 41 standard door 01.130.616.1 1 unit600 2200 46 standard door 01.130.620.1 1 unit700 1200 23 standard door 01.130.601.1 1 unit700 1800 37 standard door 01.130.613.1 1 unit700 2000 41 standard door 01.130.617.1 1 unit700 2200 46 standard door 01.130.621.1 1 unit800 1200 23 standard door 01.130.602.1 1 unit800 1800 37 standard door 01.130.614.1 1 unit800 2000 41 standard door 01.130.618.1 1 unit800 2200 46 standard door 01.130.622.1 1 unit

600 1200 23 double door 01.131.850.1 1 unit600 1800 37 double door 01.131.862.1 1 unit600 2000 41 double door 01.131.866.1 1 unit600 2200 46 double door 01.131.870.1 1 unit700 1200 23 double door 01.131.851.1 1 unit700 1800 37 double door 01.131.863.1 1 unit700 2000 41 double door 01.131.867.1 1 unit700 2200 46 double door 01.131.871.1 1 unit800 1200 23 double door 01.131.852.1 1 unit800 1800 37 double door 01.131.864.1 1 unit800 2000 41 double door 01.131.868.1 1 unit800 2200 46 double door 01.131.872.1 1 unit

MaterialSheet steel 1.0 mmSingle security glass panel 4.0 mm,clear glass, double door 6.0 mm

Finish / ColourPowder-coated, RAL 7035 texturedDoor trims, RAL 9011

Supply schedule1 Glass door1 Design trimMounting material

MIR00057_E

MIR0059_E

miracel Sheet Steel DoorW H D HU/U h d kg Model Order no. UP Price600 1200 23 standard door 01.130.576.1 1 unit600 1800 37 standard door 01.130.588.1 1 unit600 2000 41 standard door 01.130.592.1 1 unit600 2200 46 standard door 01.130.596.1 1 unit700 1200 23 standard door 01.130.577.1 1 unit700 1800 37 standard door 01.130.589.1 1 unit700 2000 41 standard door 01.130.593.1 1 unit700 2200 46 standard door 01.130.597.1 1 unit800 1200 23 standard door 01.130.578.1 1 unit800 1800 37 standard door 01.130.590.1 1 unit800 2000 41 standard door 01.130.594.1 1 unit800 2200 46 standard door 01.130.598.1 1 unit

600 1200 23 double door 01.131.820.1 1 unit600 1800 37 double door 01.131.835.1 1 unit600 2000 41 double door 01.131.840.1 1 unit600 2200 46 double door 01.131.845.1 1 unit700 1200 23 double door 01.131.821.1 1 unit700 1800 37 double door 01.131.836.1 1 unit700 2000 41 double door 01.131.841.1 1 unit700 2200 46 double door 01.131.846.1 1 unit800 1200 23 double door 01.131.822.1 1 unit800 1800 37 double door 01.131.837.1 1 unit800 2000 41 double door 01.131.842.1 1 unit800 2200 46 double door 01.131.847.1 1 unit

MaterialSheet steel 1.0 mm

Finish / ColourPowder-coated, RAL 7035 texturedDoor trims, RAL 9011

Supply schedule1 Sheet steel door1 Design trimMounting material

MIR00058_E

MIR00060_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 20

Page 31: Shkaf Knurr Electronics e

by knürr

21

MIR00068_E

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Door StopW H D HU/U h d kg Model Order no. UP Price

01.130.764.7 1 unit

- Variable adjustment, max. 180°

MaterialFlat rolled steel 15 x 3 mm

FinishZinc passivated, colourless chrome-plated

Supply schedule1 Door stopMounting material

MIR00210_E

Door Lock SetW H D HU/U h d kg Model Order no. UP Price

05.041.299.9 1 unit

Supply schedule1 Lock2 Keys (cylinder)

NoteAdditional cylinder locks on request!

MIR00066_E

Lock Set, Side / RearW H D HU/U h d kg Model Order no. UP Price

01.130.938.9 1 unit

Supply schedule1 Lockable fastener2 Keys

Lock Set, CompleteW H D HU/U h d kg Model Order no. UP Price

01.130.940.9 1 unit

Supply schedule2 Cylinders with 4 keys2 Lockable fasteners for side panel with 4

keys

MIR00069_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 21

Page 32: Shkaf Knurr Electronics e

by knürr

22

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

miracel Side PanelW H D HU/U h d kg Model Order no. UP Price

1200 600 23 01.130.643.1 1 unit1800 600 37 01.130.646.1 1 unit2000 600 41 01.130.647.1 1 unit2200 600 46 01.130.648.1 1 unit1200 800 23 01.130.649.1 1 unit1800 800 37 01.130.652.1 1 unit2000 800 41 01.130.653.1 1 unit2200 800 46 01.130.654.1 1 unit1200 900 23 01.130.655.1 1 unit2000 900 41 01.130.659.1 1 unit2200 900 46 01.130.660.1 1 unit

MaterialSheet steel 1.0 mm

Finish / ColourPowder-coated, RAL 7035 textured

Supply schedule1 Side panelMounting material

miracel Rear PanelW H D HU/U h d kg Model Order no. UP Price600 1200 23 01.130.662.1 1 unit600 1800 37 01.130.665.1 1 unit600 2000 41 01.130.666.1 1 unit600 2200 46 01.130.667.1 1 unit700 1200 23 01.130.668.1 1 unit700 1800 37 01.130.671.1 1 unit700 2000 41 01.130.672.1 1 unit700 2200 46 01.130.673.1 1 unit800 1200 23 01.130.674.1 1 unit800 1800 37 01.130.677.1 1 unit800 2000 41 01.130.678.1 1 unit800 2200 46 01.130.679.1 1 unit

MaterialSheet steel 1.0 mm

Finish / ColourPowder-coated, RAL 7035 textured

Supply schedule1 Rear panelMounting material

MIR00064_E

MIR00064_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 22

Page 33: Shkaf Knurr Electronics e

by knürr

23

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

miracel PlinthStationary, height 100 mmW H D HU/U h d kg Model Order no. UP Price600 100 600 01.130.538.1 1 unit600 100 800 01.130.539.1 1 unit600 100 900 01.130.540.1 1 unit700 100 600 01.130.544.1 1 unit700 100 800 01.130.545.1 1 unit700 100 900 01.130.546.1 1 unit800 100 600 01.130.550.1 1 unit800 100 800 01.130.551.1 1 unit800 100 900 01.130.552.1 1 unit600 100 900 with tilt protection 01.127.270.1 1 unit700 100 900 with tilt protection 01.127.271.1 1 unit

FinishPowder-coated, RAL 7035 textured

Supply schedule4 Plinth corners with levelling2 Plinth trims with vent slots2 Plinth trims, closed, sideMounting material

MIR00414_E

miracel PlinthStationary, height 200 mmW H D HU/U h d kg Model Order no. UP Price600 200 600 01.130.958.1 1 unit600 200 800 01.130.959.1 1 unit600 200 900 01.130.960.1 1 unit700 200 600 01.130.964.1 1 unit700 200 800 01.130.965.1 1 unit800 200 600 01.130.970.1 1 unit800 200 800 01.130.971.1 1 unit

FinishPowder-coated, RAL 7035 textured

Supply schedule4 Plinth corners8 TrimsMounting material

MIR00076_E

miracel PlinthMobile, height 100 mmW H D HU/U h d kg Model Order no. UP Price600 100 600 01.130.561.1 1 unit600 100 800 01.130.562.1 1 unit600 100 900 01.130.563.1 1 unit700 100 600 01.130.565.1 1 unit700 100 800 01.130.566.1 1 unit800 100 600 01.130.569.1 1 unit800 100 800 01.130.570.1 1 unit800 100 900 01.130.571.1 1 unit600 100 900 with tilt protection 01.127.260.1 1 unit700 100 900 with tilt protection 01.127.261.1 1 unit

FinishPowder-coated, RAL 7035 textured

Supply schedule1 Plinth frame2 Fixed castors with lock2 Swivel castorsMounting material

MIR00077_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 23

Page 34: Shkaf Knurr Electronics e

by knürr

24

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

miracel Plinth TrimWith brush stripW H D HU/U h d kg Model Order no. UP Price600 01.130.744.1 1 unit800 01.130.745.1 1 unit

- For cable entry, side, front and rear

FinishPowder-coated, RAL 7035 textured

Supply schedule1 Plinth trim with brush strip Mounting material

MIR005211_E

miracel Filter Mat for Plinth TrimFor use in the plinth trim on the front and rear sideW H D HU/U h d kg Model Order no. UP Price600 01.130.530.9 1 unit700 01.130.531.9 1 unit800 01.130.532.9 1 unit

Supply schedule2 Filter mats

MIR00161_E

miracel Bottom Cover3-PieceW H D HU/U h d kg Model Order no. UP Price600 600 01.130.750.0 1 unit600 800 01.130.751.0 1 unit600 900 01.130.752.0 1 unit700 600 01.130.753.0 1 unit700 800 01.130.754.0 1 unit800 600 01.130.756.0 1 unit800 800 01.130.757.0 1 unit800 900 01.130.758.0 1 unit

Material / FinishSheet steel 1.5 mm, zinc passivated

Supply schedule3 Bottom covers2 Mounting bracketsMounting material

MIR00357_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 24

Page 35: Shkaf Knurr Electronics e

by knürr

25

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

miracel Bottom CoverFor cable entry with sponge rubber seal, IP 40W H D HU/U h d kg Model Order no. UP Price600 600 01.130.732.0 1 unit600 800 01.130.733.0 1 unit600 900 01.130.734.0 1 unit700 600 01.130.735.0 1 unit700 800 01.130.736.0 1 unit800 600 01.130.738.0 1 unit800 800 01.130.739.0 1 unit800 900 01.130.740.0 1 unit

Material / FinishSheet steel 1.5 mm, zinc passivated

Supply schedule1 Cable entry2 Bottom covers2 Mounting bracketsMounting material

MIR00355_E

miracel Top CoverClosed, IP 55W H D HU/U h d kg Model Order no. UP Price600 600 01.130.690.1 1 unit600 800 01.130.691.1 1 unit600 900 01.130.692.1 1 unit700 600 01.130.694.1 1 unit700 800 01.130.695.1 1 unit700 900 01.130.696.1 1 unit800 600 01.130.691.1 1 unit800 800 01.130.699.1 1 unit800 900 01.130.700.1 1 unit

FinishPowder-coated, RAL 7035 textured

Supply schedule1 Top cover closedMounting material

MIR00070_E

miracel Top CoverWith cable entry, IP 40W H D HU/U h d kg Model Order no. UP Price600 600 01.130.900.1 1 unit600 800 01.130.901.1 1 unit600 900 01.130.902.1 1 unit700 600 01.130.903.1 1 unit700 800 01.130.904.1 1 unit800 600 01.130.906.1 1 unit800 800 01.130.907.1 1 unit

FinishPowder-coated, RAL 7035 textured

Supply schedule1 Top cover with cable entrySliding cover for cable entryMounting material

MIR00539_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 25

Page 36: Shkaf Knurr Electronics e

by knürr

26

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

miracel Top CoverWith vent lid and cable entry, IP 40W H D HU/U h d kg Model Order no. UP Price600 600 01.130.500.1 1 unit600 800 01.130.501.1 1 unit600 900 01.130.502.1 1 unit700 600 01.130.503.1 1 unit700 800 01.130.504.1 1 unit800 600 01.130.506.1 1 unit800 800 01.130.507.1 1 unit800 900 01.130.508.1 1 unit

FinishPowder-coated, RAL 7035 textured

Supply schedule1 Vent lid, completeCovers for cable entryMounting material

MIR00538_E

miracel Brush StripW H D HU/U h d kg Model Order no. UP Price

for rack width 700/800 01.130.999.9 1 unitfor rack width 600 01.130.998.9 1 unit

- Brush strip for all top covers with cableentry

- For dust protected and flexible cable entry- To be mounted instead of the sliding covers

in the lid

Supply schedule2 Brush strips

MIR00426_E

Front Trim, HingedW H D HU/U h d kg Model Order no. UP Price

1003 23 for rack width 800 01.113.044.1 1 unit1803 41 for rack width 800 01.113.048.1 1 unit2002 46 for rack width 800 01.113.049.1 1 unit

- For covering the side jumpering space onthe front in miracel racks, width 800

- With jumpering work, easy to open

MaterialSheet steel 1.0 mm

FinishPowder-coated, RAL 7035 textured

Supply schedule2 Front trimsMounting material

ELM00103a_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 26

Page 37: Shkaf Knurr Electronics e

by knürr

27

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

miracel 19“ Vertical Extrusion, SteelWith mounting holesW H D HU/U h d kg Model Order no. UP Price

16 714 shortened installation 01.130.805.0 1 unit23 1025 shortened installation 01.130.807.0 1 unit

1200 23 1100 01.130.803.0 1 unit1600 32 1500 01.130.808.0 1 unit1800 37 1700 01.130.809.0 1 unit2000 41 1900 01.130.810.0 1 unit2200 46 2100 01.130.811.0 1 unit

- For front and rear installation in the rack- Caged nut can be mounted in the HU

increment (19“)- Please be sure to order mounting kit for

initial installation of vertical extrusions

Supply schedule2 Vertical extrusions with mounting holes

MaterialSheet steel

MIR00309_E

miracel Vertical Extrusion MEPS20 ModuleW H D HU/U h d kg Model Order no. UP Price

1800 66 1700 Alu-T-SLOT 01.130.847.0 1 unit2000 74 1900 Alu-T-SLOT 01.130.848.0 1 unit2200 82 2100 Alu-T-SLOT 01.130.849.0 1 unit

1800 66 1700 steel mounting holes 01.130.822.0 1 unit2000 74 1900 steel mounting holes 01.130.823.0 1 unit2200 82 2100 steel mounting holes 01.130.824.0 1 unit

- For metric racks, 20 module- Please order the corresponding mounting

kit for rack widths 700 / 800

Supply schedule2 Vertical extrusions with increment slideSpring nut adjustment variable, as instandard increment

MIR00308_E

MIR00311_E

miracel 19“ Vertical Extrusion, AluminiumWith T-slot and increment slideW H D HU/U h d kg Model Order no. UP Price

16 714 shortened installation 01.130.830.0 1 unit23 1025 shortened installation 01.130.832.0 1 unit

1200 23 1100 01.130.828.0 1 unit1600 32 1500 01.130.833.0 1 unit1800 37 1700 01.130.834.0 1 unit2000 41 1900 01.130.835.0 1 unit2200 46 2100 01.130.836.0 1 unit

- For front and rear installation in the rack- Spring nut variable adjustment, adjustment

in HU increment (19’’)- Please be sure to order mounting kit for

initial installation of vertical extrusions

Supply schedule2 Vertical extrusions with increment slide

MaterialExtruded aluminium, polishedMIR00307_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 27

Page 38: Shkaf Knurr Electronics e

by knürr

28

RACK SYSTEMS

miracel 19“ Server Extrusion, SteelWith mounting holesW H D HU/U h d kg Model Order no. UP Price

2000 41 01.127.214.0 1 unit2200 46 01.127.215.0 1 unit

- For mounting trade standard 19’’ servers- Please order the corresponding mounting

kit for rack widths 700 / 800 - Please order mounting adapter for Knürr

standard installations

MaterialSheet steel, zinc passivated

Supply schedule4 19’’ Server extrusions

miracel Mounting Adapter for 19“ Server ExtrusionW H D HU/U h d kg Model Order no. UP Price

1 01.127.119.9 1 unit

- For mounting Knürr standard installations(storage shelves, drawers, chassis runners,keyboard runners etc.) in the 19’’ installa-tion area

MaterialSheet steel, zinc passivated

Supply schedule4 Adapters

miracel Mounting Kits for ExtrusionsW H D HU/U h d kg Model Order no. UP Price700 shortened installation 01.131.219.7 1 unit800 shortened installation 01.131.221.7 1 unit

700 full installation 01.131.220.7 1 unit800 full installation 01.131.222.7 1 unit

miracel Swing Frame 90º / 105º / 130ºW H D HU/U h d kg Model Order no. UP Price800 1800 33 1470.5 01.117.078.1 1 unit800 2000 38 1692.8 01.117.079.1 1 unit800 2200 42 1870.6 01.117.080.1 1 unit

Maximum installation weight80 kg

Order mounting kit01.131.317.1

Swing frame earth set01.110.610.9

Supply schedule1 Frame2 Horizontal runners1 Square keyMounting material

MIR00322_E

MIR00323_E

MIR80020_E

MIR80021_E

MIR00510_E

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Supply schedule4 Node brackets (full installation)2 Node brackets (shortened installation)2 Z Brackets (shortened installation)Mounting material

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 28

Page 39: Shkaf Knurr Electronics e

by knürr

29

RACK SYSTEMS

19“ Swing Frame 180ºUp to 200 kgW H D HU/U h d kg Model Order no. UP Price800 1800 35 1559 01.131.426.1 1 unit800 2000 39 1737 01.131.430.1 1 unit800 2200 44 1959 01.131.434.1 1 unit

- The rack must be bolted to the floor whenusing a swing frame.

- The installation of a swing frame reducesthe nominal installation height of the rackby 2 HU.

- Please be sure to also order the mountingkit with side panel screw fixing for loads≥ 80 kg installation weight!

FinishPowder-coated, RAL 7035 textured

Supply schedule1 19’’ Swing frame, complete1 Horizontal mounting top1 Horizontal mounting bottom1 Square keyMounting materialMIR00209_E

MIR00315_E

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

MIR00319_E

Mounting Kit, Base FixingW H D HU/U h d kg Model Order no. UP Price

01.130.934.7 1 unit

MaterialSheet steel, 3.0 mm

FinishZinc passivated

Supply schedule4 Clamping plates

miracel Mounting Kit, Side Panel Screw Fixing W H D HU/U h d kg Model Order no. UP Price

01.130.937.9 1 unit

MaterialCountersunk washers and mounting nuts,stainless steel

Supply schedule16 Countersunk washers16 Mounting nuts M516 Countersunk screws M5 x 12

MIR00318_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 29

Page 40: Shkaf Knurr Electronics e

by knürr

30

RACK SYSTEMS

miracel Rack ConnectorW H D HU/U h d kg Model Order no. UP Price

01.130.935.7 1 unit

Supply schedule8 Mounting bracketsMounting material

MIR00100_E

miracel Sealing Frame for Rack Suites, IP 55W H D HU/U h d kg Model Order no. UP Price

1053 600 23 475 01.131.233.1 1 unit1653 600 37 475 01.131.251.1 1 unit1853 600 41 475 01.131.257.1 1 unit2053 600 46 475 01.131.263.1 1 unit

1053 800 23 675 01.131.234.1 1 unit1653 800 37 675 01.131.252.1 1 unit1853 800 41 675 01.131.258.1 1 unit2053 800 46 675 01.131.264.1 1 unit1853 900 41 775 01.131.259.1 1 unit

MIR00304_E

MaterialSheet steelSeal, PU sealing foam

FinishPowder-coated, RAL 7035 textured

Supply schedule1 Sealing frame

miracel Cover Extrusion for Rack Suites, IP 20W H D HU/U h d kg Model Order no. UP Price

T 600 23 01.131.270.9 1 unitT 600 37 01.131.273.9 1 unitT 600 41 01.131.274.9 1 unitT 600 46 01.131.275.9 1 unitT 800 23 01.131.276.9 1 unitT 800 37 01.131.279.9 1 unitT 800 41 01.131.280.9 1 unitT 800 46 01.131.281.9 1 unitT 900 23 01.131.282.9 1 unitT 900 37 01.131.285.9 1 unitT 900 41 01.131.286.9 1 unitT 900 46 01.131.287.9 1 unit

MIR00320_E

MaterialPVC Extrusion, black

Supply schedule2 Lengths, vertical2 Lengths, depth

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 30

Page 41: Shkaf Knurr Electronics e

by knürr

31

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. installation height, d = Useful depthHU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Earthing Set, RackW H D HU/U h d kg Model Order no. UP Price

01.130.529.9 1 unit

MIR00216_E

MIR00217_E

Supply schedule5 EarthlinesMounting material

Earthing Set, DoorW H D HU/U h d kg Model Order no. UP Price

01.130.624.9 1 unit

Supply schedule1 EarthlineMounting material

miracel Trim Extrusion KitW H D HU/U h d kg Model Order no. UP Price600 23 01.131.440.1 1 unit600 32 01.131.442.1 1 unit600 37 01.131.443.1 1 unit600 41 01.131.444.1 1 unit600 46 01.131.445.1 1 unit600 23 for server rack B 600 01.131.437.1 1 unit600 41 for server rack B 600 01.131.438.1 1 unit

FinishPowder-coated, RAL 7035 textured

Supply schedule2 Covers, horizontal2 Covers, verticalMounting materialMIR00305_E

miracel Connection BoardW H D HU/U h d kg Model Order no. UP Price600 200 closed 01.131.601.1 1 unit800 200 closed 01.131.602.1 1 unit600 400 closed 01.131.603.1 1 unit800 400 closed 01.131.604.1 1 unit

600 200 with cable entry 01.131.607.1 1 unit800 200 with cable entry 01.131.608.1 1 unit

- The corresponding shortened rear panel isalso provided in the product range

FinishPowder-coated, RAL 7035 textured

Supply schedule1 Connection board with or without cable

cutout1 Horizontal sealing extrusionMounting material

MIR00306_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 31

Page 42: Shkaf Knurr Electronics e

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 32

Page 43: Shkaf Knurr Electronics e

Strong Points and technical details Page 34Product Page 35

tecoras ETS Racks

tecoras

by knürr

33

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 33

Page 44: Shkaf Knurr Electronics e

by knürr

34

RACK SYSTEMS

Flexibility- The height-adjustable wall

mounting allows flexible mounting for the rack to matchsurrounding environments.

- Optional cable entry over gridflooring or hollow flooring.

ApprovalThe ETS racks have the DeutscheTelekom certificate of approval.

VentilationThe rack construction designfavours natural convection.

1

tecoras ETS RackStrong points

TEC00030_E

TEC00251_E

The ETS system rack complies withETS 300 119-3 (EuropeanTelecommunications Standard) andthe technical supply conditions5805-3158 of Deutsche Telekom forinstallation in accordance with IEC917 and IEC 297.

Material- Basic rack, sheet steel 2.0 mm- Doors and rear panel,

sheet steel 1.0 mm- Roof, sheet steel 1.5 mm- Plinth trim, sheet steel

2.0 mm

Finish- Vertical posts and mounting

brackets for cable grid connec-tion, zinc passivated and chrome-plated (Fe/Zn 6-12 cB)

- Basic racks, doors, rear paneland plinth trim, powder-coatedRAL 7032, pebble grey textured

ConfigurationStationary, on levelling feet

Static loads- Maximum load with uniform

distrubution: 2300 N- Maximum permissible load with

cable runway and cable: 1900 N- Maximum compressive load on

the floor exerted by feet: 490N/cm2

tecoras ETS RackTechnical data

1

TEC00083_E

tecoras ETS Rack DimensioningW H D CW w h d600 2200 300 500 515 2052

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 34

Page 45: Shkaf Knurr Electronics e

by knürr

35

RACK SYSTEMS

ETS RackFor installations in accordance with IEC 917 and IEC 297W H D Model Order no. UP Price600 2200 300 ETS System rack 01.100.001.3 1 unit

Front door closed 01.100.010.3 1 unitFront door perforated 01.100.011.3 1 unitRear panel 01.100.021.3 1 unitRoof, closed 01.100.031.3 1 unitPlinth trim with option for socket 01.100.053.3 1 unit

TEC00090_E

ETS System rack complies with ETS300 119-3 (European TelecommunicationsStandard) and the technical supply conditions5805-3158 of Deutsche Telekom for installati-ons in accordance with IEC 917 and IEC 297.

Standard features- Welded version, height 2200 mm

consists of:1 Basic rack

consisting of 2 side panels and4 bracing struts

2 Levelling feet4 Cable restraints2 ESD Jacks

30 Caged nuts M6 (pack)

ETS RackFor installations in accordance with IEC 917 and IEC 297W H D HU/U h d Model Order no. UP Price600 2200 300 01.100.003.3 1 unit

Standard features- Flat pack version, height 2200 mm, for

mounting on-site, consisting of:2 Side panels4 Bracing struts2 Levelling feet4 Cable restraints2 ESD Jacks2 L Rails with cable holder for

connection to the cable gridMounting material30 Caged nuts M6 (pack)

ETS RackFor installations in accordance with IEC 917 and IEC 297W H D HU/U h d Model Order no. UP Price600 2200 300 170 01.100.004.3 1 unit

Standard features- Welded version, height 2200 mm with

recessed side panels and recessedmounting level for 170 mm installationdepth consisting of:1 Basic rack

consisting of 2 side panels and4 bracing struts

8 Cable covers2 Levelling feet4 Cable restraints2 ESD Jacks2 L Rails with cable holder for connection

to the cable grid 30 Caged nuts M6 (pack)

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 35

Page 46: Shkaf Knurr Electronics e

by knürr

36

RACK SYSTEMS

ETS RackFor installations in accordance with IEC 917 and IEC 297W H D HU/U h d Model Order no. UP Price600 2200 300 170 01.100.005.3 1 unit

Standard features- Welded version, height 2200 mm with

recessed side panels and recessedmounting level for 170 mm installationdepth, earthquake-proof in accordancewith Telcordia GR-63-CORE zone 4, consisting of:1 Basic rack

consisting of 1 bottom cover, 1 topcover and 2 side panels

8 Cable covers4 Cable restraints2 ESD Jacks2 L Rails with cable holder for connec-

tion to the cable grid30 Caged nuts M6 (pack)

ETS RackFor installations in accordance with IEC 917 and IEC 297W H D HU/U h d Model Order no. UP Price600 1800 300 01.100.006.3 1 unit

Standard features- Welded version, height 1800 mm

consisting of:1 Basic rack

consisting of 2 side panels and4 bracing struts

2 Levelling feet3 Cable restraints2 ESD Jacks2 L Rails with cable holder for connec-

tion to the cable grid 30 Caged nuts M6 (pack)

ETS System RackFor installations in accordance with IEC 917 and IEC 297W H D HU/U h d Model Order no. UP Price600 2200 600 01.100.007.3 1 unit

Standard features- Welded version, height 2200 mm and

depth 600 mm consisting of:1 Basic rack

consisting of 2 side panels and4 bracing struts

4 Levelling feet4 Cable restraints2 ESD Jacks2 L Rails with cable holder for connec-

tion to the cable grid 30 Caged nuts M6 (pack)

TEC00251_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 36

Page 47: Shkaf Knurr Electronics e

by knürr

37

ETS RackFor 23“ InstallationsW H D HU/U h d Model Order no. UP Price

2200 300 01.100.008.3 1 unit

Standard features- Welded version, height 2200 mm and

depth 300 mm consisting of:1 Basic rack

consisting of 2 side panels and4 bracing struts

2 Levelling feet4 Cable restraints2 ESD Jacks2 L Rails with cable holder for connection

to the cable grid30 Caged nuts M6 (pack)

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 37

Page 48: Shkaf Knurr Electronics e

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 38

Page 49: Shkaf Knurr Electronics e

Strong Points and technical details Page 40Product Page 42Accessories Page 44

smaract 19“ Enclosure, Indoor

smaract

by knürr

39

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 39

Page 50: Shkaf Knurr Electronics e

by knürr

40

RACK SYSTEMS

Forward-thinkingFlexibility with the integration of19” technology.Choice of 6 heights from 9HU to 24 HU.

AccessAccess from all sides is a time-saving factor with, forexample, system integrationor maintanence.

First-class designLow weight with innovative frameconcept. Nevertheless, high stability with new triangularextrusions.

Grows with requirementsEasy expansion with stackablecomponents.

Cable managementNo matter how complex, Knürrcreates the right solutions.

EMC and IP modelsThe small rack can be equippedat any time to meet IP or EMCstandards. (Also in combinedIP/EMC model)

6

5

4

3

2

1

smaractStrong points

SMA20005_E3 SMA20004_E4

SMA20017_E1 SMA20006_E2

SMA20056_E5

SMA20046_E6

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 40

Page 51: Shkaf Knurr Electronics e

by knürr

41

RACK SYSTEMS

Material- Extruded aluminium- Corner connector, die-cast

aluminium- Covers, sheet steel- Doors, sheet steel or with

single security glass panel,opening angle, 180°

19” Installations in accordancewith IEC 297-3- Height: 9 HU to 24 HU

1HU (i.e. 1U) = 44.45 mm- Width: 482.6 mm (19”)

Models- IP 20- IP 54- EMC

Space provided- 82% of the basic surface as

useable surface for installationand cable routing

Configuration- Stationary, on levelling feet- Mobile on castors with lock

Finish- Basic rack, polished- Covers, powder-coated, RAL

7035 light-grey textured

Static load- 2000 N With stationary model

How supplied- Fully assembled

Tests in line with model- Safety in accordance with EN

50298 and EN 60950- Protective conductor / earth in

accordance with DIN VDE 0701-1

- Vibration test in accordancewith MIL-STD 810 E

- Vibration and shock test inaccordance with DIN EN300019-2-2

- IP Test in accordance with DINEN 60529

- EMC Shielding attenuation inaccordance with IEEE-STD-299and VG 95 373 part 15 (30 MHz -1 GHz)

- Plastic components comply withUL 94-VO

smaract 19” Enclosure, In Accordance with IEC 297Technical data

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 41

Page 52: Shkaf Knurr Electronics e

by knürr

42

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, CRS = Cable routing set, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

smaract 19” EnclosureWith glass doorW H D HU/U h d kg Model Order no. UP Price600 478 600 9 with glass door 02.110.007.1 1 unit600 612 600 12 with glass door 02.110.012.1 1 unit600 745 600 15 with glass door 02.110.017.1 1 unit600 879 600 18 with glass door 02.110.022.1 1 unit600 1012 600 21 with glass door 02.110.027.1 1 unit

600 478 800 9 with glass door 02.110.009.1 1 unit600 745 800 15 with glass door 02.110.019.1 1 unit600 1012 800 21 with glass door 02.110.029.1 1 unit

600 745 900 15 with perforated door 02.110.020.1 1 unit600 1012 900 21 with perforated door 02.110.030.1 1 unit

SMA20024_E

SMA20025_E

- For installations in accordance with IEC 297-3

- Covers removable

Supply schedule1 Basic rack2 Side panels, closed, hinged on both

sides1 Cover, closed1 Glass front door (*)1 Rear door with cable entry,

lockable, prepared for ventilation unit(**)

2 19’’ Aluminium vertical extrusions,front, with T-slot, includes incrementslide (***)

1 Earthing set4 Levelling feet

*) with D 900 front door with perforation**) with D 900 rear door with perforation***) with D 900, 4 19“ server extrusions

NotePlease order mounting adapter for 19“server extrusions. Set with 4 adapters01.127.119.9

smaract 19” EnclosureWithout doorW H D HU/U h d kg Model Order no. UP Price600 478 600 9 without door 02.110.107.1 1 unit600 745 600 15 without door 02.110.117.1 1 unit600 1012 600 21 without door 02.110.127.1 1 unit

600 478 800 9 without door 02.110.109.1 1 unit600 745 800 15 without door 02.110.119.1 1 unit600 1012 800 21 without door 02.110.129.1 1 unit

SMA20027_E

- For installations in accordance with IEC 297-3

- Covers removable

Supply schedule1 Basic rack2 Side panels, closed, hinged on both

sides1 Cover, closed1 Trim frame, front 1 Rear door with cable entry,

lockable, prepared for ventilation unit2 19’’ Aluminium vertical extrusions,

front, with T-slot, includes incrementslide

1 Earthing set4 Levelling feet

SMA20026_E

SMA20042_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 42

Page 53: Shkaf Knurr Electronics e

by knürr

43

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, CRS = Cable routing set, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

SMA20026_E

SMA20024_3_E

smaract 19” Enclosure IP 54With glass doorW H D HU/U h d kg Model Order no. UP Price600 612 600 12 with glass door 02.110.212.1 1 unit600 879 600 18 with glass door 02.110.222.1 1 unit600 1146 600 24 with glass door 02.110.232.1 1 unit

600 612 800 12 with glass door 02.110.214.1 1 unit600 879 800 18 with glass door 02.110.224.1 1 unit600 1146 800 24 with glass door 02.110.234.1 1 unit

- For installations in accordance with IEC 297-3

- Covers removable

Supply schedule1 Basic rack2 Side panels, IP 54, closed, hinged on

both sides1 Top cover, IP 54, closed1 Bottom cover, IP 54, closed1 Glass front door, IP 541 Rear door, IP 54, closed, screwed2 19’’ Aluminium vertical extrusions,

front, with T-slot, includes incrementslide

1 Earthing set4 Levelling feet

NoteIP 54 Accessories on request

smaract 19” Enclosure EMCWith steel doorW H D HU/U h d kg Model Order no. UP Price600 879 600 18 with steel door 02.110.322.1 1 unit600 879 800 18 with steel door 02.110.324.1 1 unit

- For installations in accordance with IEC 297-3

- Covers removable

Supply schedule1 Basic rack2 Side panels, EMC, closed, hinged on

both sides1 Top cover, EMC, closed1 Bottom cover, EMC, closed1 Front door, EMC, closed1 Rear door, EMC, closed, screwed2 19“ Aluminium vertical extrusions,

front, with T-slot, includes incrementslide

1 Earthing set4 Levelling feet

NoteEMC Accessories on request

SMA20026_E

SMA20024_4_E

SMA20026_E

SMA20026_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 43

Page 54: Shkaf Knurr Electronics e

by knürr

44

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, CRS = Cable routing set, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight, OU = Office unit, LD = Linking dimen-sions

smaract 19” Aluminium ExtrusionWith T-slotW H D HU/U h d kg Model Order no. UP Price

9 02.111.146.9 1 unit12 02.111.147.9 1 unit15 02.111.148.9 1 unit18 02.111.149.9 1 unit21 02.111.150.9 1 unit24 02.111.151.9 1 unit

- For installation front and rear

Material / Finish19’’ Extrusions: extruded aluminium,polishedMounting bracket: zinc passivated sheetsteel

Supply schedule2 19’’ Extrusions with T-slot, includes

increment slide4 Mounting bracketsMounting material

How suppliedFlat-packed kit

smaract 19” Sheet Steel ExtrusionWith mounting holesW H D HU/U h d kg Model Order no. UP Price

9 02.111.156.9 1 unit12 02.111.157.9 1 unit15 02.111.158.9 1 unit18 02.111.159.9 1 unit21 02.111.160.9 1 unit24 02.111.161.9 1 unit

- For installation front and rear

Material / Finish19’’ Extrusions: zinc passivated sheetsteelMounting bracket: zinc passivated sheetsteel

Supply schedule2 19’’ Extrusions with mounting holes4 Mounting bracketsMounting material

How suppliedFlat-packed kit

smaract Top / Bottom Cover, ClosedW H D HU/U h d kg Model Order no. UP Price

600 02.111.052.1 1 unit800 02.111.054.1 1 unit900 02.111.055.1 1 unit

Material / FinishSheet steel, powder-coated, textured

ColourRAL 7035 light-grey

Supply schedule1 Cover, closedMounting material

How suppliedFlat-packed kit

smaract Bottom Cover, PerforatedWith filter matW H D HU/U h d kg Model Order no. UP Price

600 02.111.062.1 1 unit800 02.111.064.1 1 unit900 02.111.065.1 1 unit

- For cooling with air convection

Material / FinishTop cover: sheet steel, powder-coated,textured Filter mat: Filedon

ColourRAL 7035 light-grey

Supply schedule1 Bottom cover, perforated, with filter matMounting material

How suppliedFlat-packed kit

SMA20030_E

SMA20032_E

SMA20028_E

SMA20029_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 44

Page 55: Shkaf Knurr Electronics e

by knürr

45

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, CRS = Cable routing set, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

smaract Twin Swivel CastorW H D HU/U h d kg Model Order no. UP Price

02.111.175.9 4 units

- Height 50 mm

ColourRAL 9011 graphite black

Load rating500 N Per castor1500 N Maximum static overall load per rack

Supply schedule2 Twin castors2 Fixed castors

How suppliedFlat-packed kit

smaract Rear Door, ClosedW H D HU/U h d kg Model Order no. UP Price

9 02.111.076.1 1 unit12 02.111.077.1 1 unit15 02.111.078.1 1 unit18 02.111.079.1 1 unit21 02.111.080.1 1 unit

Supply schedule1 Rear door closedMounting material

Material / FinishSheet steel, powder-coated, textured

How suppliedFlat-packed kit

ColourRAL 7035 light-grey

smaract Ventilation UnitW H D HU/U h d kg Model Order no. UP Price

02.111.180.9 1 unit

- Easy fixing to rear panel- With two axial fans - With thermostat

Material / FinishZinc passivated sheet steel

Supply schedule1 Fan unit wired ready for connection,

with thermostatMounting material

How suppliedPre-assembled

smaract Replacement Filter MatW H D HU/U h d kg Model Order no. UP Price

600 02.111.068.9 5 units800 02.111.069.9 5 units900 02.111.069.9 5 units

- For use in conjunction with perforated bot-tom cover

MaterialFiledon

Supply schedule5 Replacement filter mats

How suppliedFlat-packed kit

SMA20031_E

SMA20033_E

SMA20034_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 45

Page 56: Shkaf Knurr Electronics e

by knürr

46

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, CRS = Cable routing set, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

smaract Stacking SetW H D HU/U h d kg Model Order no. UP Price

02.111.171.9 4 units

- Fixed connection for stacking small racks

Material / FinishSteel, cold rolled zinc passivated

Supply schedule4 Stacking elementsMounting material

How suppliedFlat-packed kit

SMA20035_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 46

Page 57: Shkaf Knurr Electronics e

Strong Points and technical details Page 48Product Page 50Accessories Page 52

doubleprorack Indoor Racks

by knürr

47

RACK SYSTEMS

doubleprorack

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 47

Page 58: Shkaf Knurr Electronics e

by knürr

48

RACK SYSTEMS

Complete 19” enclosure range ofbench case 6 HU up to small rack24 HU.

Various top and bottom covervariants with individual require-ments for air throughput and IPprotection are provided in theproduct range.Top and bottom covers can becombined with one another invarious ways.

Lockable front door, optionally ofsingle security glass panel or assheet steel door.

The extrusions for installing 19”components are provided withmounting holes or with a T-slotfor variable or incrementedmounting.

The 19” mounting level is depthadjustable on the 25 mm incre-ment. Consequently, when usinga door, higher front panel super-structures can also be installed.

Individual configurations foryour specific application enableuneven base units to be levelledwith the levelling feet; mobilitywith castors or stackability withenclosure feet.

As an additional alternative, aplinth with front vent screen provides space for cabling andventilation from below.

Using the various doors, appea-rance and service access can beindividually modelled while takingthe required protection ratinginto account.

Different types of cable entry areprovided according to the requi-red protection rating.

9

8

7

6

5

4

3

2

1

doubleprorackStrong points

DOP00245_E3

DOP20004_E4

DOP20005_E4

DOP00242_E1 DOP00244_E2

DOP00248_E6

DOP00252_E8

DOP00247_E5

DOP00250_E7

DOP00251_E8

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 48

Page 59: Shkaf Knurr Electronics e

by knürr

49

RACK SYSTEMS

Die-cast aluminium frame construction connected withaluminium depth and verticalextrusions

Material- Covers, sheet steel 0.8 mm,

zinc passivated- Die-cast aluminium frame- Extruded aluminium depth and

vertical extrusions- On the 19” mounting level;

extruded aluminium extrusionwith T-slot and mounting holes

- Sheet steel full glass doors orextrusion doors with sheet steelor security glass panel

External dimensioning- Widths

554.4 mm654.4 (network enclosure)754.4 (network enclosure)

- Depths400, 500, 600, 700 or 800 mm

- Height177.8 – 1111.3 mm (without feetor plinth)

Installation space in compliancewith IEC 297-3- Height 3 – 24 HU

(1 HU = 44.45 mm)– Width 19”

How supplied- Assembled

Load rating- 1500 N static

Configuration- Stationary, on plastic feet or

plinth with feet- Mobile on twin swivel castors

Finish / Colour– Covers, powder-coated, light-

grey textured RAL 7035- Frame and extrusion, powder-

coated, grey-blue textured RAL5008

Application-specific solutions- IP 54 Sealed- EMC Shielded- Network enclosures- Integrated vent unit

Tests- IP Test in accordance with DIN

40050/IEC 529- EMC Measurements in accor-

dance with VG 95 373 part 15- Vibration test in accordance

with MIL-STD 810 D- NEMA 12 Test

doubleprorack 19” Enclosure in Compliance with IEC 297-3Technical data

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 49

Page 60: Shkaf Knurr Electronics e

by knürr

50

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, CRS = Cable routing set, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

doubleprorack 19” EnclosureWithout front doorW H D HU/U h d kg Model Order no. UP Price554.4 311.2 500 6 265.9 460 without door 01.243.506.1 1 unit554.4 355.6 500 7 310.3 460 without door 01.243.507.1 1 unit554.4 400.1 500 8 354.8 460 without door 01.243.508.1 1 unit554.4 444.5 500 9 399.2 460 without door 01.243.509.1 1 unit554.4 489.0 500 10 443.7 460 without door 01.243.510.1 1 unit554.4 577.9 500 12 532.6 460 without door 01.243.512.1 1 unit554.4 711.4 500 15 666.1 460 without door 01.243.515.1 1 unit554.4 844.6 500 18 799.3 460 without door 01.243.518.1 1 unit554.4 978.1 500 21 932.8 460 without door 01.243.521.1 1 unit554.4 1111.3 500 24 1066.0 460 without door 01.243.524.1 1 unit

554.4 311.2 600 6 265.9 560 without door 01.243.606.1 1 unit554.4 355.6 600 7 310.3 560 without door 01.243.607.1 1 unit554.4 400.1 600 8 354.8 560 without door 01.243.608.1 1 unit554.4 444.5 600 9 399.2 560 without door 01.243.609.1 1 unit554.4 489.0 600 10 443.7 560 without door 01.243.610.1 1 unit554.4 577.9 600 12 532.6 560 without door 01.243.612.1 1 unit554.4 711.4 600 15 666.1 560 without door 01.243.615.1 1 unit554.4 844.6 600 18 799.3 560 without door 01.243.618.1 1 unit554.4 978.1 600 21 932.8 560 without door 01.243.621.1 1 unit554.4 1111.3 600 24 1066.0 560 without door 01.243.624.1 1 unit

554.4 577.9 700 12 532.6 660 without door 01.243.712.1 1 unit554.4 711.4 700 15 666.1 660 without door 01.243.715.1 1 unit554.4 844.6 700 18 799.3 660 without door 01.243.718.1 1 unit554.4 978.1 700 21 932.8 660 without door 01.243.721.1 1 unit554.4 1111.3 700 24 1066.0 660 without door 01.243.724.1 1 unit

- For installations in accordance with IEC 297-3

- Side panels removable- Rear panel removable- Covers above and below with side vent slots - Rear side, vent screen 3 HU/U- Stacking or levelling feet

Supply schedule1 Frame rack with side panels1 Cover above,

with vent slots1 Cover below,

with vent slots2 19” Extrusions front, with mounting

holes2 19” Extrusions rear , with T-slotType 1 (up to 9 HU/U) with closed rearpanel and stacking feetType 2 (from 10 HU/U) with closed rearpanel, with rear side vent screen, 3 HU/Uand levelling feet

doubleprorack 19” Enclosure IP 54With glass door with extruded aluminium frameW H D HU/U h d kg Model Order no. UP Price554.4 577.9 600 12 532.6 485 with glass door 01.245.612.1 1 unit554.4 844.6 600 18 799.3 485 with glass door 01.245.618.1 1 unit554.4 1111.3 600 24 1066 485 with glass door 01.245.624.1 1 unit

554.4 577.9 800 12 532.6 685 with glass door 01.245.812.1 1 unit554.4 844.6 800 18 799.3 685 with glass door 01.245.818.1 1 unit554.4 1111.3 800 24 1066 685 with glass door 01.245.824.1 1 unit

- For installations in accordance with IEC 297-3

- Side panels removable- Rear panel removable- Covers above and below closed- Sealed door, cannot be locked, with single

safety glass panel- With levelling feet - Protection rating IP 54

Supply schedule1 Frame rack with side panels, sealed2 Covers, closed1 Rear panel, closed, sealed2 19’’ Extrusions, front with mounting

holes2 19’’ Extrusions, rear, with T-slot1 Front door4 Levelling feet

DOP00052_E

DOP00064_E

DOP00253_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 50

Page 61: Shkaf Knurr Electronics e

by knürr

51

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, CRS = Cable routing set, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weightt

DOP00230_E

DOP00256_E

doubleprorack LAN 19” Network Free-Standing EnclosuresW H D HU/U h d kg Model Order no. UP Price554.4 311 500 6 265 335 with full glass door 01.246.541.1 1 unit554.4 444 500 9 399 335 with full glass door 01.246.542.1 1 unit554.4 577 500 12 532 335 with full glass door 01.246.543.1 1 unit554.4 711 500 15 666 335 with full glass door 01.246.544.1 1 unit554.4 844 500 18 799 335 with full glass door 01.246.545.1 1 unit554.4 978 500 21 932 335 with full glass door 01.246.546.1 1 unit554.4 1111 500 24 1066 335 with full glass door 01.246.547.1 1 unit

554.4 577 600 12 532 435 with sheet steel door 01.246.633.1 1 unit554.4 844 600 18 799 435 with sheet steel door 01.246.635.1 1 unit554.4 1111 600 24 1066 435 with sheet steel door 01.246.637.1 1 unit

554.4 311 600 6 265 435 with full glass door 01.246.641.1 1 unit554.4 444 600 9 399 435 with full glass door 01.246.642.1 1 unit554.4 577 600 12 532 435 with full glass door 01.246.643.1 1 unit554.4 711 600 15 666 435 with full glass door 01.246.644.1 1 unit554.4 844 600 18 799 435 with full glass door 01.246.645.1 1 unit554.4 978 600 21 932 435 with full glass door 01.246.646.1 1 unit554.4 1111 600 24 1066 435 with full glass door 01.246.647.1 1 unit

554.4 577 800 12 532 635 with sheet steel door 01.246.833.1 1 unit554.4 844 800 18 799 635 with sheet steel door 01.246.835.1 1 unit554.4 1111 800 24 1066 635 with sheet steel door 01.246.837.1 1 unit

554.4 577 800 12 577 635 with full glass door 01.246.843.1 1 unit554.4 711 800 15 666 635 with full glass door 01.246.844.1 1 unit554.4 844 800 18 799 635 with full glass door 01.246.845.1 1 unit554.4 978 800 21 932 635 with full glass door 01.246.846.1 1 unit554.4 1111 800 24 1066 635 with full glass door 01.246.847.1 1 unit

654.4 1111 600 15 666 435 with full glass door 01.246.684.1 1 unit654.4 1111 600 24 1066 435 with full glass door 01.246.687.1 1 unit654.4 711 800 15 666 635 with full glass door 01.246.884.1 1 unit

754.4 711 600 15 666 435 with full glass door 01.246.694.1 1 unit754.4 844 600 18 799 435 with full glass door 01.246.695.1 1 unit754.4 978 600 21 932 435 with full glass door 01.246.696.1 1 unit754.4 711 800 15 666 635 with full glass door 01.246.894.1 1 unit754.4 844 800 18 799 635 with full glass door 01.246.895.1 1 unit754.4 978 800 21 932 635 with full glass door 01.246.896.1 1 unit

- Protection rating IP 20- With fixed 19’’ installation- For installations in accordance with

IEC 297-1- Side panels removable- Rear panel removable, 3-piece- Covers above and below with side vent slots

Supply schedule1 Frame rack, includes side panels1 Rear panel with cable entry,

3-piece1 Cover above,

with vent slots1 Cover below,

with vent slots1 Set 19’’ installation (4 vertical extrusi-

ons with T-slot)1 Earthing set with earthing bolts MBType 1: with sheet steel doorType 2: with full glass door

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 51

Page 62: Shkaf Knurr Electronics e

by knürr

52

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

doubleprorack Sheet Steel DoorW H D HU/U h d kg Model Order no. UP Price554.4 6 01.240.473.1 1 unit554.4 9 01.240.476.1 1 unit554.4 12 01.240.478.1 1 unit554.4 15 01.240.479.1 1 unit554.4 18 01.240.480.1 1 unit554.4 21 01.240.481.1 1 unit554.4 24 01.240.482.1 1 unit

- With cylinder lock, lockable- Not suitable for enclosures with which an IP

protection of 54 must be attained.

MaterialSheet steel 1.0 mm

ColourPowder-coated, textured, RAL 7035 light-grey

Supply schedule1 Sheet steel door

How suppliedPre-assembled

doubleprorack Rear Panel, ClosedW H D HU/U h d kg Model Order no. UP Price554.4 3 01.240.451.1 1 unit554.4 6 01.240.454.1 1 unit554.4 9 01.240.457.1 1 unit554.4 12 01.240.459.1 1 unit554.4 15 01.240.460.1 1 unit554.4 18 01.240.461.1 1 unit554.4 21 01.240.462.1 1 unit

654.4 6 01.244.146.1 1 unit654.4 9 01.244.149.1 1 unit654.4 12 01.244.152.1 1 unit654.4 15 01.244.155.1 1 unit654.4 18 01.244.158.1 1 unit654.4 21 01.244.161.1 1 unit

754.4 6 01.244.176.1 1 unit754.4 9 01.244.179.1 1 unit754.4 12 01.244.182.1 1 unit754.4 15 01.244.185.1 1 unit754.4 18 01.244.188.1 1 unit754.4 21 01.244.191.1 1 unit

- For doubleprorack widths 554.4 mm, 654.4 mm and 754.4 mm

MaterialSheet steel 0.8 mm

Finish / ColourPowder-coated, textured, RAL 7035 light-grey

Supply schedule1 Rear panel, closedMounting material

How suppliedFlat-packed kit

DOP00260_E

DOP00275_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 52

Page 63: Shkaf Knurr Electronics e

by knürr

53

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

doubleprorack Ventilated Rear Panel 3 HU/UW H D HU/U h d kg Model Order no. UP Price554.4 132.5 3 without thermostat 01.243.425.1 1 unit554.4 132.5 3 with thermostat 01.243.428.1 1 unit654.4 132.5 3 without thermostat 01.243.477.1 1 unit654.4 132.5 3 with thermostat 01.243.483.1 1 unit754.4 132.5 3 without thermostat 01.243.480.1 1 unit754.4 132.5 3 with thermostat 01.243.484.1 1 unit

- With axial fans (220 V, maximum volumeflow per fan, 160 m2/h)

- Plastic protective grid

Supply schedule1 Fan, rear panel, wiredMounting materialType 1 without thermostatType 2 with thermostat 10 - 60°C and

power supply lead, 2.5 mm

Finish / ColourPowder-coated, textured, RAL 7035 light-grey

How suppliedAssembled

doubleprorack Connection BoardWith cable entryW H D HU/U h d kg Model Order no. UP Price554.4 132.5 3 01.243.435.1 1 unit

- For cable entry in conjunction with corre-sponding rear panel, shortened by 3 HU/U

MaterialSheet steel 0.8 mm, zinc passivated

Finish / ColourPowder-coated, textured, RAL 7035 light-grey

Supply schedule1 Connection board with cable entryMounting material

How suppliedFlat-packed kit

doubleprorack Connection BoardWith brush stripW H D HU/U h d kg Model Order no. UP Price554.4 132.5 3 01.243.438.1 1 unit

- For rear panel cover in conjunction with corresponding rear panel shortened by 3HU/U

- For doubleprorack width 554.4 mm- With brush strip for cable cutout and strain

relief

Finish / ColourPowder-coated, textured, RAL 7035 light-grey

Supply schedule1 Connection boardMounting material

How suppliedFlat-packed kit

ELM00107_E

DOP00287_E

DOP00288_E

DOP00272_E

DOP00270_E

DOP00274_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 53

Page 64: Shkaf Knurr Electronics e

by knürr

54

ELM00127_E

DOP00301_E

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

doubleprorack Rear Panel, Closed, IP 54 W H D HU/U h d kg Model Order no. UP Price554.4 5 01.245.450.1 1 unit554.4 8 01.245.453.1 1 unit554.4 9 01.245.454.1 1 unit554.4 15 01.245.457.1 1 unit

- For doubleprorack width 554.4 mm- Protection rating IP 54

MaterialSheet steel 0.8 mm

Finish / ColourPowder-coated, textured RAL 7035 light-grey

Supply schedule1 Rear panel, closedMounting material

How suppliedFlat-packed kit

doubleprorack Ventilated Rear Panel, 4 HU/U IP 54W H D HU/U h d kg Model Order no. UP Price554.4 4 without thermostat 01.245.430.1 1 unit554.4 4 with thermostat 01.245.431.1 1 unint

- For doubleprorack with enclosure width 554.4 mm

- With two axial fans (220 V, maximumvolume flow per fan 160 m3/h)

- With fan filter- Protection rating IP 54- Can be used with enclosure heights from

7 HU/U- Not suitable for EMC enclosures

Finish / ColourPowder-coated, textured, RAL 7035 light-grey

Supply schedule1 Fan, rear panel, wiredMounting materialType 1 without thermostatType 2 with thermostat and power supply lead, 2.5 mm

How suppliedAssembled

doubleprorack Connection Board, Closed, IP 54W H D HU/U h d kg Model Order no. UP Price554.4 132.5 3 01.243.430.1 1 unit

- For screwing/bolting- Doubleprorack enclosure width 554.4 mm- Protection rating IP 54

MaterialSheet steel 1 mm

Finish / ColourPowder-coated, textured, RAL 7035 light-grey

Supply schedule1 Connection boardMounting material

How suppliedFlat-packed kit

DOP00275_E

DOP00273_E

DOP00269_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 54

Page 65: Shkaf Knurr Electronics e

by knürr

55

DOP00289_E

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

doubleprorack Connection Board IP 54With cable cutoutW H D HU/U h d kg Model Order no. UP Price554.4 132.5 3 01.245.440.1 1 unit

- For rear panel cover in conjuction with corresponding rear panel shortened by 3HU/U

- For doubleprorack width 554.4 mm, fromenclosure height 6 HU/U

- For cable cutout and strain relief - With installation in doubleprorack enclosu-

res - depending on the other rack compo-nents - a maximum protection rating of IP53 can be reached.

Finish / ColourPowder-coated, textured, RAL 7035 light-grey

Supply schedule1 Connection boardMounting material

How suppliedFlat-packed kit

doubleprorack Twin Castors, 50 mmW H D HU/U h d kg Model Order no. UP Price

50 01.240.527.9 1 unit

- For mobile installation of the doubleprorackstand-alone enclosure with fixed castors

Material / FinishPolyamid, RAL 9011 black

Load rating500 N static

Supply schedule2 Twin castors2 Fixed castors4 Washer disks

How suppliedFlat-packed kit

doubleprorack PlinthW H D HU/U h d kg Model Order no. UP Price554.4 100 500 01.240.539.1 1 unit554.4 100 600 01.240.540.1 1 unit554.4 100 700 01.240.541.1 1 unit554.4 100 800 01.240.542.1 1 unit

- For doubleprorack stand-alone enclosures- With levelling feet- With ventilation use- Height = 100 mm

Material / FinishAir throughput screen: ABSCovers: sheet steel 1 mm

Finish / ColourFrame rack, powder-coated, textured,RAL 5008 grey-blueCover, powder-coated, textured, RAL 7035light-grey

Supply schedule1 PlinthMounting material

How suppliedFlat-packed kit

DOP00233_E

DOP00271_E

DOP00267_E

DOP00250_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 55

Page 66: Shkaf Knurr Electronics e

by knürr

56

DOP00313_E

DOP00055_E

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

doubleprorack 19” Installation, Front SideWith T-slotW H D HU/U h d kg Model Order no. UP Price

6 01.240.440.9 1 unit7 01.240.441.9 1 unit8 01.240.442.9 1 unit9 01.240.443.9 1 unit

10 01.240.444.9 1 unit12 01.240.445.9 1 unit15 01.240.446.9 1 unit18 01.240.447.9 1 unit21 01.240.448.9 1 unit24 01.240.449.9 1 unit

- Can also be used as second mounting level

MaterialExtruded aluminium

FinishPolished

Supply schedule2 19’’ Extrusions, front with T-slotMounting material

How suppliedFlat-packed kit

doubleprorack 19” Installation, Front SideWith mounting holesW H D HU/U h d kg Model Order no. UP Price

6 01.240.490.9 1 unit7 01.240.491.9 1 unit8 01.240.492.9 1 unit9 01.240.493.9 1 unit

10 01.240.494.9 1 unit12 01.240.495.9 1 unit15 01.240.496.9 1 unit18 01.240.497.9 1 unit21 01.240.498.9 1 unit24 01.240.499.9 1 unit

- Can also be used as second mounting level

MaterialExtruded aluminium

FinishPolished

Supply schedule2 19’’ Extrusions, front with mounting

holes

How suppliedFlat-packed kit

doubleprorack Earthing SetFor enclosuresW H D HU/U h d kg Model Order no. UP Price

01.243.400.9 1 unit

- For the secure earthing of the enclosure

Supply schedule2 Earthlines, length 250 mm4 Spring nuts M52 Washer disks4 Cylinder screws M5 x 10 Z51 Earthing bolt

How suppliedFlat-packed kit

DOP20004_E

DOP20005_E

DOP00285_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 56

Page 67: Shkaf Knurr Electronics e

by knürr

57

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

doubleprorack Earthing SetFor doors and trimsW H D HU/U h d kg Model Order no. UP Price

01.245.400.9 1 unit

- For the safe earthing of doors and trims

Supply schedule5 Earthlines, length 250 mm1 Earthline, length 250 mm with AMP plug5 Spring nuts M55 Tooth lock washers1 Washer6 Cylinder screws M5 x 10 Z51 Earth symbol

How suppliedFlat-packed kit

doubleprorack Earthing BarW H D HU/U h d kg Model Order no. UP Price

15 doubleprorack 01.240.543.9 1 unit18 doubleprorack 01.240.544.9 1 unit21 doubleprorack 01.240.545.9 1 unit24 doubleprorack 01.240.546.9 1 unit

- For the secure earthing and equipotentialbonding of equipment and installations

MaterialElectrolytic copper

Supply schedule1 Earthing bar2 Bar fixers2 BracketsMounting material

How suppliedFlat-packed kit

doubleprorack Contact ClampW H D HU/U h d kg Model Order no. UP Price

01.110.715.9 1 unit

- For the safe connection of equipment andinstallations in conjunction with the earthingbar

Material / FinishSheet steel, zinc passivated

Supply schedule20 Contact clamps

How suppliedFlat-packed kit

DOP00286_E

DOP00281_E

DOP20017_E

DOP20016_E

doubleprorack Eyebolt SetW H D HU/U h d kg Model Order no. UP Price

01.243.440.9 1 unit

- For hanging crane hooks - Load rating 1900 N static per ring screw

MaterialTool steel, forged

Supply schedule4 Eyebolts M 8

How suppliedFlat-packed kit

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 57

Page 68: Shkaf Knurr Electronics e

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 58

Page 69: Shkaf Knurr Electronics e

Strong Points and technical details Page 60Product Page 62Accessories Page 63

conact 19“ Wall-Mounting Rack

conact

by knürr

59

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 59

Page 70: Shkaf Knurr Electronics e

by knürr

60

RACK SYSTEMS

Cost-effectiveSavings of up to 50 % of transportvolume with flat-pack packaging.

“One-Person” setup– No unneccessary dismantling

as the enclosure is supplied inthe neccessary part flat-packformat

- Rear panel assembly requiresno measuring due to the drill-hole template

- Easy assembly with key hole-punching on the rear panelPush-in system with mounting rails and covers

- Symmetrical enclosure setup

Cabling made easy- Straightforward mounting of

installations is ensured withaccessibility from all sides

- Uncomplicated direct cable routing with cable sections provided on-site with the opendesign

- Orderly cable routing throughlarge side jumper area and withcable clamping rails as acces-sories

Customer specification- Individual configuration with

colour variants or of the covershole pattern

- 19” Or metric installation possible

- 19” Vertical extrusions depthadjustable on the 25 mm increment

- Easy door stop exchange withsliding system

- Ventilation concept can beexpanded at any time withoptionally active ventilation unit

Maintenance-friendly- Easy access for service purpo-

ses is also ensured by removingthe side panels

- Enclosure can also be lockedwith the security lock

- Door opening angle >180°

Accessories- Straigtforward integration of

accessories such as socketstrips with screwing points onthe vertical extrusion or on therear panel

- Also available are accessoriesfor neat and orderly cable rou-ting, e.g. cable routing board orjumpering hook

- Extensive standard accessoriesrange provided; includes, forexample, intermediate shelves,drawers, socket strips etc.

conactStrong points

ACT00005_E

ACT00004_E

ACT00006_E ACT00007_E ACT00008_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 60

Page 71: Shkaf Knurr Electronics e

by knürr

61

RACK SYSTEMS

Conact 19” wall-mounting enclosure- Complies with IEC 297- With fixed 19” installation- For installations in accordance

with IEC 297-3- Covers removable- Top and bottom cover with

brush strips for cable entry andwith side vent slots

For installation of- 19” Components front- 19” Components rear, optional

with additional 19” verticalextrusion set

- Equipment with maximumdesign width of 450 mm

- Installation accessories

19” Installation dimensions incompliance with IEC 297-3- Heights: 6 HU / 9 HU / 12 HU /

15 HU / 18 HU / 21 HU (1 HU = 44.45 mm)

- Width: 482.6 mm (19”)

External dimensions– Heights: 352 mm / 486 mm /

619 mm / 752 mm / 886 mm / 1019 mm

- Width: 600 mm- Depths: 400 mm / 500 mm /

600 mm

Jumpering area- Front: 100 mm (adjustable)- Side: 55 mm

Static load rating500 N

Protection ratingIP 20

StandardsEarthing VDE 0100 T 540,EN 60950, EN 60529

ConfigurationStationary, wall mounting

conactTechnical data

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 61

Page 72: Shkaf Knurr Electronics e

by knürr

62

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

conact Standard 19” Wall-Mounting EnclosureW H D HU/U h d kg Model Order no. UP Price600 352 400 6 270 with glass door 05.010.000.1 1 unit600 486 400 9 404 with glass door 05.010.001.1 1 unit600 619 400 12 537 with glass door 05.010.002.1 1 unit600 752 400 15 670 with glass door 05.010.003.1 1 unit600 886 400 18 804 with glass door 05.010.004.1 1 unit600 1019 400 21 937 with glass door 05.010.005.1 1 unit600 1152 400 24 1070 with glass door 05.010.006.1 1 unit

600 352 400 6 270 with sheet steel door 05.010.021.1 1 unit600 486 400 9 404 with sheet steel door 05.010.022.1 1 unit600 619 400 12 537 with sheet steel door 05.010.023.1 1 unit600 752 400 15 670 with sheet steel door 05.010.024.1 1 unit600 886 400 18 804 with sheet steel door 05.010.025.1 1 unit600 1019 400 21 937 with sheet steel door 05.010.026.1 1 unit600 1152 400 24 1070 with sheet steel door 05.010.027.1 1 unit

600 352 500 6 270 with glass door 05.010.007.1 1 unit600 486 500 9 404 with glass door 05.010.008.1 1 unit600 619 500 12 537 with glass door 05.010.009.1 1 unit600 752 500 15 670 with glass door 05.010.010.1 1 unit600 886 500 18 804 with glass door 05.010.011.1 1 unit600 1019 500 21 937 with glass door 05.010.012.1 1 unit600 1152 500 24 1070 with glass door 05.010.013.1 1 unit

600 352 500 6 270 with sheet steel door 05.010.028.1 1 unit600 486 500 9 404 with sheet steel door 05.010.029.1 1 unit600 619 500 12 537 with sheet steel door 05.010.030.1 1 unit600 752 500 15 670 with sheet steel door 05.010.031.1 1 unit600 886 500 18 804 with sheet steel door 05.010.032.1 1 unit600 1019 500 21 937 with sheet steel door 05.010.033.1 1 unit600 1152 500 24 1070 with sheet steel door 05.010.034.1 1 unit

600 352 600 6 270 with glass door 05.010.014.1 1 unit600 486 600 9 404 with glass door 05.010.015.1 1 unit600 619 600 12 537 with glass door 05.010.016.1 1 unit600 752 600 15 670 with glass door 05.010.017.1 1 unit600 886 600 18 804 with glass door 05.010.018.1 1 unit600 1019 600 21 937 with glass door 05.010.019.1 1 unit600 1152 600 24 1070 with glass door 05.010.020.1 1 unit

600 352 600 6 270 with sheet steel door 05.010.035.1 1 unit600 486 600 9 404 with sheet steel door 05.010.036.1 1 unit600 619 600 12 537 with sheet steel door 05.010.037.1 1 unit600 752 600 15 670 with sheet steel door 05.010.038.1 1 unit600 886 600 18 804 with sheet steel door 05.010.039.1 1 unit600 1019 600 21 937 with sheet steel door 05.010.040.1 1 unit600 1152 600 24 1070 with sheet steel door 05.010.041.1 1 unit

Material / Finish- Rear panel and basic rack, sheet steel,

zinc passivated - Covers (removable), sheet steel,

powder-coated- Front door, single security glass panel

or sheet steel, powder-coated- 19“ Vertical extrusion, sheet steel,

zinc passivated

ColourRAL 7035 light-grey

Supply schedule1 Wall-standing enclosure2 19” Vertical extrusions1 Cable clamping railMounting material

How suppliedPart flat-pack

conact Mounting SetW H D HU/U h d kg Model Order no. UP Price

05.010.331.9 1 unit

- For mounting front panels, chassis runners,socket strips and other installations

Supply schedule50 Caged nuts M550 Cylinder screws M5 x 850 Countersunk screws M5 x 1650 Rosettes M525 Serrated (tooth) locking nuts M5

ACT00010_E

ACT00002_E

MIR00644_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 62

Page 73: Shkaf Knurr Electronics e

by knürr

63

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

ACT00035_E

Conact Design DoorW H D HU/U h d kg Model Order no. UP Price600 6 type 1 05.010.411.X 1 unit600 9 type 1 05.010.412.X 1 unit600 12 type1 05.010.413.X 1 unit600 15 type 1 05.010.414.X 1 unit600 18 type 1 05.010.415.X 1 unit600 21 type 1 05.010.416.X 1 unit600 24 type 1 05.010.417.x 1 unit

600 6 type 2 05.010.401.X 1 unit600 9 type 2 05.010.402.X 1 unit600 12 type 2 05.010.403.X 1 unit600 15 type 2 05.010.404.X 1 unit600 18 type 2 05.010.405.X 1 unit600 21 type 2 05.010.406.X 1 unit600 24 type 2 05.010.407.x 1 unit

- Can be used instead of the standard sheetsteel or glass door

Material / FinishSheet steel, powder-coated

Colour combinationsFinal digit of order number .1:RAL 7035 light-grey /RAL 5018 turquoiseblueFinal digit of order number .2:RAL 7035 light-grey /RAL 5018 sapphireblue

Supply schedule1 Design doorMounting materialType 1: closedType 2: perforated

Conact Vertical Extrusion 19”MetricW H D HU/U h d kg Model Order no. UP Price

6 19“ 05.010.321.9 1 unit9 19“ 05.010.322.9 1 unit

12 19“ 05.010.323.9 1 unit15 19“ 05.010.324.9 1 unit18 19“ 05.010.325.9 1 unit21 19“ 05.010.326.9 1 unit24 19“ 05.010.327.9 1 unit

6 metric 05.010.311.9 1 unit9 metric 05.010.312.9 1 unit

12 metric 05.010.313.9 1 unit15 metric 05.010.314.9 1 unit18 metric 05.010.315.9 1 unit21 metric 05.010.316.9 1 unit24 metric 05.010.317.9 1 unit

- For front and/or rear installation in theenclosure

Material / FinishSheet steel, 1.5 mm, zinc passivated

Supply schedule2 Vertical extrusionsMounting material

ACT00029_E

ACT00028_E

ACT00023_E

ACT00022_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 63

Page 74: Shkaf Knurr Electronics e

by knürr

64

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

conact Earthing SetW H D HU/U h d kg Model Order no. UP Price

05.010.330.9 1 unit

- For earthing all covers on the enclosureframe

Supply schedule5 Earthlines 6 mm2

Mounting materialACT00026_E

ACT00041_E

conact Top / Bottom Cover with Active Ventilation UnitWith thermostatW H D HU/U h d kg Model Order no. UP Price600 400 05.010.303.1 1 unit600 500 05.010.304.1 1 unit600 600 05.010.305.1 1 unit

- Can be used in place of the standard top /bottom cover

- With thermostat for regulating the internalenclosure temperature for forced ventilation

- Air throughput: 59 m3/h per fan- With cable entry via brush strips - No loss of installation height- Easy access for service work via flange

panel

Material / FinishSheet steel, powder-coated

Technical data, thermostat- Setting range: 10 - 60°C- Mains supply: 230 V / 50 Hz- Mode of contact : changeover with snap-

action characteristic- Contact rating: 10 A (4) 250 CAC (break

contact), 5 A (2) 250 VAC (make contact)- Interference suppression: “N” (in accor-

dance with VDE 0875)- Connections: 4-pole terminal 2.5 mm2

ColourRAL 7035 light-grey

Supply schedule1 Top / bottom cover1 Ventilation unit with 2 fans, wired

connectability with or without thermostat

ACT00027_E

01-112_eng_final.qxd 07.08.2002 14:51 Uhr Seite 64

Page 75: Shkaf Knurr Electronics e

Strong Points and technical details Page 66Product Page 68Accessories Page 77

tecoras Outdoor Racks

Strong Points and technical details Page 81Product Page 82Accessories Page 83

tecoras Wall Case

Strong Points Page 84Product Page 85

tecoras Thermal Management

tecoras

by knürr

65

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 65

Page 76: Shkaf Knurr Electronics e

by knürr

66

Individual configuration- Identical basic and add-on

modules in 4 heights and 2 dep-ths can be extended in modularform to multiple combinations

- Future security due to installati-on space and adaption for 19“,metric and non-standard equip-ment, extensive accessoryrange

Universal add-on capability- Easy connection of cabinets

with pilot-pin guiding and add-on connections, also possiblefor basic cabinets being used aspart of the operation

- Easy transport of individual mo-dules and add-on at installationsite

- Damaged covers can be easilyand service-friendly exchanged

2

1 Safety-tested- The cabinets meet require-

ments in accordance with IEC721, ETS 300 019 and GR-487-CORE

- Minimum 25 dB shieldingattenuation in accordance withIEC 61 587-3

- Earthquake-proof to zone 4 inaccordance with Telcordia GR-63-CORE

- Vibration test in accordancewith IEC 68-2-6, IEC 68-2-29

- Environmentally tested inaccordance withIEC 68-2-1, IEC 68-2-2,IEC 68-2-5, IEC 68-2-56

Integrated thermal management- The integration of the heat

exchanger in the enclosure wallensures an increase of the avai-lable usage space by more than15%

- Use of extensive cooling for thefirst time with low cabinet dep-ths (‹ 400 mm) for use in publicaccess areas

- Disruptions of air flow are pre-vented with large spatial sepa-ration of air entry and exitpoints

- Hot spot prevention with speci-fic internal air circulation

4

3

tecoras OutdoorStrong Points

TEC00088_E1

TEC00009_E2

TEC00279_E3

TEC00124_E4

RACK SYSTEMS

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 66

Page 77: Shkaf Knurr Electronics e

by knürr

67

RACK SYSTEMS

EMC SealingIn standard

IP Protection rating- IP 55

External covers finish Powder-coated, RAL 7035 light-grey, outdoor quality in accordan-ce with GSB International, coarsetexture

Load ratingStatic up to 4000 N

Options- TECORAS thermal components

for door installation (see thermal management)- Heat exchanger- Cooling unit

- Heating (see thermal manage-ment)

- Vertical installation extrusions,19“ or metric (see accessories)

- Cable entry panel (see accesso-ries)

- Cable entry troughs with andwithout filter box (see accesso-ries)

Single or double skinned outdoorenclosure for installation of - 19“ and metric components- Non-standard equipment

Main unit- Basic frame of extruded alumi-

nium AIMgSi0,5 with die-castaluminium corner connectors,polished

- Bottom and top cover, rearpanel, corner extrusions andside panels of chrome-platedaluminium AIMg3, 1 mm, polis-hed

External covers- Of 2 mm colourless chrome-

plated aluminium AIMg3- 2 Side covers- Rear cover screwed from the

inside- Solar protection roof, hinged- All screwing and connecting

elements on the inside

DoorDouble skinned closed or ventedfor installation of TECORAS ther-mal components- Can be used as front and rear

door, door stop on right or left - Strong hidden die-cast alumini-

um hinges- Swing handle for profile half

cylinder with saw protection- Triple interlocking system- The intervening ‘tongue’ in the

rack extrusion ensures highlocking pressure with lowassembly input Door locking with openingangles 90º and 135º

tecoras OutdoorTechnical data

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 67

Page 78: Shkaf Knurr Electronics e

by knürr

68

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

tecoras Basic Cabinet B 700Front door right, closedW H D HU/U h d kg Model Order no. UP Price

1000 405 895 20 330 63 01.901.003.1 1 unit1180 405 1075 24 330 69 01.901.005.1 1 unit1400 405 1295 29 330 76 01.901.007.1 1 unit1580 405 1475 33 330 81 01.901.009.1 1 unit1000 705 895 20 630 81 01.901.013.1 1 unit1180 705 1075 24 630 88 01.901.015.1 1 unit1400 705 1295 29 630 97 01.901.017.1 1 unit1580 705 1475 33 630 104 01.901.019.1 1 unit

- Double skinned, outdoor enclosure withadd-on capability for installation of

- 19“ and metric components- Non-standard units with maximum

installation width, 535 mm- Different cabinet combinations can be

constructed from the same basic modules.

- Double cabinets or triple cabinets arecreated by adding-on one or two add-oncabinets ( = basic cabinet without sidecovers and side panels). The extensionis made instead of the side cover.

- These combinations can also be moun-ted on the right or left with an add-onenclosure. The extension is made at theside cover.

Supply schedule1 Main unit consisting of basic frame, top

and bottom cover, rear panel, 2 corner extrusions

1 Rear panel2 Side panels2 Side covers1 Solar protection roof1 Front door, hinged on right, closed1 Plinth, 210 mm height, galvanised sheet

steel with 2 side covers, 1 removablefront and rear trim

1 Earthing set1 Cable entry panel, closed

Thermal management basic equipping - Naturally ventilated double panels- Naturally ventilated roof

How suppliedFully assembled

TEC00098_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 68

Page 79: Shkaf Knurr Electronics e

by knürr

69

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

tecoras Add-On Cabinet B 635Front door right, closedW H D HU/U h d kg Model Order no. UP Price

1000 405 895 20 330 49 01.901.303.1 1 unit1180 405 1075 24 330 52 01.901.305.1 1 unit1400 405 1295 29 330 57 01.901.307.1 1 unit1580 405 1475 33 330 61 01.901.309.1 1 unit1000 705 895 20 630 59 01.901.313.1 1 unit1180 705 1075 24 630 62 01.901.315.1 1 unit1400 705 1295 29 630 67 01.901.317.1 1 unit1580 705 1475 33 630 71 01.901.319.1 1 unit

Supply schedule1 Main unit consisting of basic frame, top

and bottom cover, rear panel, 2 cornerextrusions

1 Rear panel1 Solar protection roof1 Front door, hinged on right, closed1 Plinth, 210 mm height, galvanised sheet

steel, 1 removable front and rear trim1 Earthing set1 Cable entry panel, closed1 Add-on set

Thermal management basic equipping - Naturally ventilated rear panel- Naturally ventilated roof

How suppliedFully assembled

TEC00098_E

TEC00098_E

tecoras Basic Cabinet with Add-On Enclosure W 1025W H D HU/U h d kg Model Order no. UP Price

1000 705 895 20 630 105 01.901.202.1 1 unit1180 705 1075 24 630 116 01.901.204.1 1 unit1400 705 1295 29 630 130 01.901.206.1 1 unit1580 705 1475 33 630 141 01.901.208.1 1 unit

- Double skinned, outdoor enclosure withadd-on capability for installation of

- 19“ and metric components- Non-standard units with maximum

installation width, 535 mm- Different cabinet combinations can be

constructed from the same basic modules.

- Double cabinets or triple cabinets arecreated by adding-on one or two add-oncabinets ( = basic cabinet without sidecovers and side panels). The extensionis made instead of the side cover.

- These combinations can also be moun-ted on the right or left with an add-onenclosure. The extension is made at theside cover.

Supply schedule1 Basic cabinet W 700 without side cover,

left1 Add-on enclosure, left

How supplied Fully assembled

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 69

Page 80: Shkaf Knurr Electronics e

by knürr

70

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

tecoras Double Door CabinetW H D HU/U h d kg Model Order no. UP Price1270 1000 405 895 20 330 108 01.901.531.1 1 unit1270 1180 405 1075 24 330 117 01.901.532.1 1 unit1270 1400 405 1295 29 330 129 01.901.533.1 1 unit1270 1580 405 1475 33 330 138 01.901.534.1 1 unit1270 1000 705 895 20 630 136 01.901.536.1 1 unit1270 1180 705 1075 24 630 147 01.901.537.1 1 unit1270 1400 705 1295 29 630 161 01.901.538.1 1 unit1270 1580 705 1475 33 630 172 01.901.539.1 1 unit

- Double skinned compact outdoor enclosurewith double door and central bracket forinstallation of

- 2 x 19’’ and metric components for cabinet width 1270 mm

- Non-standard units with maximuminstallation width, 890 and 1100 mm

- Expansion of the cabinet combinations withadd-on cabinets and add-on enclosures isalso an option

Thermal management basic equipping - Ventilated double panels- Ventilated roof

Double door- Closed or ventilated for using thermal

components - Double door with central bracket- Right and left door can be locked sepa-

rately

Supply schedule1 Main unit consisting of basic frame, top

and bottom cover, 2 side panels, rearpanel, 2 corner extrusions

2 Side covers1 Rear panel cover1 Solar protection roof1 Double door, sealing on right and left,

closed1 Plinth, 210 mm height, galvanised sheet

steel, with 2 side covers, 1 removablefront and rear trim

1 Earthing set2 Cable entry panels, closed

TEC00146_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 70

Page 81: Shkaf Knurr Electronics e

by knürr

71

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

Heat Exchanger CabinetW H D HU/U h d kg Model Order no. UP Price

700 1000 405 850 19 330 83 55 W/K 01.900.003.1 1 unit700 1180 405 1030 220 330 89 80 W/K 01.900.005.1 1 unit700 1400 405 1250 280 330 96 85 W/K 01.900.007.1 1 unit700 1580 405 1430 320 330 101 95 W/K 01.900.009.1 1 unit700 1000 705 850 19 630 101 95 W/K 01.900.023.1 1 unit700 1180 705 1030 220 630 108 110 W/K 01.900.025.1 1 unit700 1400 705 1250 280 630 117 115 W/K 01.900.027.1 1 unit700 1580 705 1430 320 630 124 125 W/K 01.900.029.1 1 unit

1335 1000 405 850 19 300 143 110 W/K 01.900.401.1 1 unit1335 1180 405 1030 220 300 152 135 W/K 01.900.402.1 1 unit1335 1400 405 1250 280 300 164 140 W/K 01.900.403.1 1 unit1335 1580 405 1430 320 300 174 155 W/K 01.900.404.1 1 unit1335 1000 705 850 19 600 171 145 W/K 01.900.411.1 1 unit1335 1180 705 1030 220 600 182 170 W/K 01.900.412.1 1 unit1335 1400 705 1250 280 600 196 175 W/K 01.900.413.1 1 unit1335 1580 705 1430 320 600 207 195 W/K 01.900.414.1 1 unit

Double skinned outdoor enclosure withintegrated air-to-air heat exchanger withenclosure protection rating IP 55 forinstallation of:- 19’’ And metric components- Non-standard units with maximum

installation width 535 mm (standardcabinet) and 2 x 535 mm (double cabinet)

Integrated heat exchanger principle- Integration of the heat exchanger in the

external panels - Fans and electronic control board instal-

led in the roof for maximum useful volu-me

- Optimised positioning of air entry andexit ensures lowest wind disruption ofthe airflow

- Sound pressure level, less than 55 dB(A)at 1 m distance, in accordance with ISO 7779

Thermal management basic equipping- Active ventilated and ribbed side and

rear panels- One fan module with 2 fans with integra-

ted electronic control board 48 VDC forexternal and internal circulation forstandard cabinet with 700 mm width

- Two fan modules each with 2 fans withintegrated electronic control board 48VDC for external and internal circulationfor standard cabinet with 1335 mmwidth

- Active solar protection with roof fan

Standard cabinet W 700 supply schedule1 Basic frame with bottom cover and 2

corner extrusions 2 Double skinned ribbed side panels with

internal channel plates1 Double skinned ribbed rear panel with

internal channel plate1 Fan module with 2 fans 48 VDC,

thermostat regulated1 Solar protection roof1 Double skinned front door, stop on

right, closed1 Plinth, 210 mm height, galvanised sheet

steel, with 2 side covers, 1 removablefront and rear trim

1 Earthing set1 Cable entry panel

Double cabinet W 1335 supply scheduleThe double cabinet consists of basic andadd-on cabinets:2 Basic frames with bottom cover and 4

corner extrusions, assembled togetherwith add-on connectors

2 Double skinned ribbed side panels withinternal channel plates

2 Double skinned ribbed rear panels withinternal channel plates

2 Fan modules with 2 fans 48 VDC, ther-mostat regulated

2 Solar protection roofs2 Double skinned front doors, hinged on

right and left, closed2 Plinths, 210 mm height, galvanised

sheet steel, with 2 side covers, 2 removable trims, front and rear

2 Earthing sets2 Cable entry panels, closed

How suppliedFully assembled

TEC00149_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 71

Page 82: Shkaf Knurr Electronics e

by knürr

72

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

Innovative solutionStreet Cabinet side and rear panelsare fabricated from one piece. Thisenables a design with a minimumamount of joints.

Thermal protectionThe filter fan installed in the topcover (with Street Cabinet FAN)ensures that hot spots are pre-vented and consequently providesthermal protection for installedunits.

1

Integrated thermal managementThe air-to-air heat exchangerintegrated in the rear panel (withStreet Cabinet HEC) enables opti-mal cooling in the smallestinstallation area on with protec-tion rating IP 55.

Easy configurationTogether with the enclosure, theearth plinth available as anaccessory made of fibre-glassreinforced polyester provides acompletely configurable ready toconnect system. The compatibil-ity of the connection dimensionswith plinths in accordance withDIN 43629 allows unlimitedexchange of enclosures of existing installations.

Functional accessoriesThe mounting panel with 19“adapter provides flexible upgradewith 19” components and DINrails or non-standard units usedin an application. The divided cable entry withbrush enables flexible cablemanagement, for example, thelead through of completely pre-formed cables.

Space economySpace-saving operational ele-ments, displays, telecommunica-tions distributors and power sup-ply components can be mountedin the enclosure with side door.Various front and side doorlocking devices allow separaterights of access.

5

4

3

2

Street CabinetStrong points

TEC00247_E1

TEC00258_E2

TEC00257_E3

TEC00266_E4

TEC00264_E5

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 72

Page 83: Shkaf Knurr Electronics e

by knürr

73

RACK SYSTEMS

TEC00352_E

IP Protection rating- IP 55 For model with closed

door- IP 54 For model with ventilated

door

External covers finish- Powder-coated, RAL 7035

light-grey, outdoor quality inaccordance with GSBInternational, coarse texture

Options- 1 Plinth, 210 mm height, galva-

nised sheet steel, with remov-able front trim

- 1 Fibre-glass reinforced poly-ester plinth (see accessories)

- Heating (see thermal manage-ment)

- Vertical installation extrusions,19“ or metric (see accessories)

- Mounting panel (see accessories)

- Divided cable entry panel (seeaccessories)

- Divided cable entry panel (seeaccessories)

- Cable entry panel, closed (see accessories)

- Cabinet made of galvanisedsheet steel

Single skinned outdoor enclosure foruse in public access areas with amaximum depth of 500 mm andmaximum height of 1290 mm forinstallation of- 19“ and metric components- Non-standard equipment for DIN

rails and fixing mounting panels

Main unit- Basic frame of extruded alumi-

nium AIMgSi0,5 with die-castaluminium corner connectors,polished

- Top and bottom cover of chro-me-plated aluminium AIMg3, 2 mm, polished

External covers- Of 2 mm colourles chrome-

plated aluminium AIMg3- One-piece jacket functioning as

side piece and rear panel- Solar protection roof, screwed- All screwing and connection

elements on the inside

Door- Standard door or double door

without central bracket insingle skinned version, closedor ventilated

- Double skinned door for enclo-sure with increased EMC pro-tection

- Swing handle for profile halfcylinder with saw protection

- Triple interlocking system:The intervening ‘tongue’ in therack extrusion ensures highlocking strength with lowassembly input

- Hidden hinges- Door locking with opening

angles 90º and 135º- The optional side door on the

right or left is set up in thesame way as the front door

Street CabinetTechnical data

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 73

Page 84: Shkaf Knurr Electronics e

by knürr

74

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

tecoras Street Cabinet SCAluminiumW H D HU/U w h d Model Order no. UP Price640 780 375 15 535 675 335 Street Cabinet 01.917.000.1 1 unit640 780 475 15 535 675 435 Street Cabinet 01.917.005.1 1 unit740 780 375 15 635 675 335 Street Cabinet 01.917.010.1 1 unit740 780 475 15 635 675 435 Street Cabinet 01.917.015.1 1 unit640 1000 375 20 535 895 335 Street Cabinet 01.917.001.1 1 unit640 1000 475 20 535 895 435 Street Cabinet 01.917.006.1 1 unit740 1000 375 20 635 895 335 Street Cabinet 01.917.011.1 1 unit740 1000 475 20 635 895 435 Street Cabinet 01.917.016.1 1 unit640 1180 375 24 535 1075 335 Street Cabinet 01.917.002.1 1 unit640 1180 475 24 535 1075 435 Street Cabinet 01.917.007.1 1 unit740 1180 375 24 635 1075 335 Street Cabinet 01.917.012.1 1 unit740 1180 475 24 635 1075 435 Street Cabinet 01.917.017.1 1 unit

740 780 375 15 635 675 335 with side door 01.917.020.1 1 unit740 780 475 15 635 675 435 with side doorr 01.917.030.1 1 unit740 1000 375 20 635 895 335 with side door 01.917.022.1 1 unit740 1000 475 20 635 895 435 with side door 01.917.032.1 1 unit740 1180 375 24 635 1075 335 with side door 01.917.024.1 1 unit740 1180 475 24 635 1075 435 with side door 01.917.034.1 1 unit

1210 780 375 15 1105 675 335 with double door 01.917.040.1 1 unit1210 780 475 15 1105 675 435 with double door 01.917.045.1 1 unit1210 1000 375 20 1105 895 335 with double door 01.917.041.1 1 unit1210 1000 475 20 1105 895 435 with double door 01.917.046.1 1 unit1210 1180 375 24 1105 1075 335 with double door 01.917.042.1 1 unit1210 1180 475 24 1105 1075 435 with double door 01.917.047.1 1 unit

Cost-effective single skinnedl outdoor enclo-sure for installation of- 19” and metric components- Non-standard units with maximum installa-

tion widths, 535 mm and 1105 mm for DINrails and for fixing mounting panel

Supply schedule, SC1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and

rear panel1 Solar protection roof1 Front door, sealing on right1 Earthing set

Supply schedule, SC with side door1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and

rear panel1 Solar protection roof1 Front door, sealing on right1 Earthing set1 Corner extrusion of basic frame1 Side door, left or right1 Partition panel

Supply schedule, SC with double door1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and

rear panel1 Solar protection roof1 Front door as double door1 Earthing set

How suppliedFully assembled

TEC00359_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 74

Page 85: Shkaf Knurr Electronics e

by knürr

75

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, d = Useful depth in the entry filter area minus 13 mm, ESD = ESD versi-on,1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

tecoras Street Cabinet FanW H D HU/U h d kg Model Order no. UP Price

640 780 375 15 675 330 01.917.050.1 1 unit640 1000 375 20 895 330 01.917.051.1 1 unit640 1180 375 24 1075 330 01.917.052.1 1 unit

640 780 475 15 675 430 01.917.055.1 1 unit640 1000 475 20 895 430 01.917.056.1 1 unit640 1180 475 24 1075 430 01.917.057.1 1 unit

740 780 375 15 657 330 01.917.060.1 1 unit740 1000 375 20 895 330 01.917.061.1 1 unit740 1180 375 24 1075 330 01.917.062.1 1 unit

740 780 475 15 675 430 01.917.065.1 1 unit740 1000 475 20 895 430 01.917.066.1 1 unit740 1180 475 24 1075 430 01.917.067.1 1 unit

740 780 375 15 657 330 with side doors 01.917.070.1 1 unit740 1000 375 20 895 330 with side doors 01.917.072.1 1 unit740 1180 375 24 1075 330 with side doors 01.917.074.1 1 unit

740 780 475 15 657 430 with side doors 01.917.080.1 1 unit740 780 475 20 675 430 with side doors 01.917.082.1 1 unit740 1000 475 24 895 430 with side doors 01.917.084.1 1 unit

1210 780 375 15 675 330 with double doors 01.917.090.1 1 unit1210 1000 375 20 895 330 with double doors 01.917.091.1 1 unit1210 1180 375 24 1075 330 with double doors 01.917.092.1 1 unit

1210 780 475 15 675 430 with double doors 01.917.095.1 1 unit1210 1000 475 20 895 430 with double doors 01.917.096.1 1 unit1210 1180 475 24 1075 430 with double doors 01.917.097.1 1 unit

Cost-effective single skinned outdoorenclosure for installation of- 19” and metric components- Non-standard equipment with maximum

installation width 535 mm for DIN railsand for fixing mounting panels

Front door- Ventilated, with entry filter for air intake- Standard or double door without central

bracket- With double door, right and left door

cannot be locked separately

Supply schedule, SC Fan with side door1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and

rear panel1 Solar protection roof1 Front door, sealing on right1 Axial fan 230 VAC, mounted on the top

cover1 Earthing set1 Corner extrusion of basic frame1 Side door, left or right1 Partition panel

Supply schedule , SC Fan with doubledoor

1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and

rear panel1 Solar protection roof2 Axial fans 230 VAC, mounted on the top

cover1 Front door as double door1 Earthing set

Supply schedule, SC Fan with doubledoor

1 Basic frame with top and bottom cover1 Jacket, U-shaped as side panels and

rear panel1 Solar protection roof1 Axial fan 230 VAC, mounted on the top

cover1 Front door, sealing on right1 Earthing set

How supplied

TEC00363_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 75

Page 86: Shkaf Knurr Electronics e

by knürr

76

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

TEC00364_E

tecoras Street Cabinet HECW H D HU/U h d kg Specific cooling capacity Order no. UP Price

640 780 375 14 630 310 25 W/K 01.917.200.1 1 unit640 1000 375 19 850 310 30 W/K 01.917.201.1 1 unit640 1180 375 23 1030 310 35 W/K 01.917.202.1 1 unit

640 780 475 14 630 410 25 W/K 01.917.205.1 1 unit640 1000 475 19 850 410 30 W/K 01.917.206.1 1 unit640 1180 475 23 1030 410 35 W/K 01.917.207.1 1 unit

740 780 375 14 630 310 25 W/K 01.917.210.1 1 unit740 1000 375 19 850 310 30 W/K 01.917.211.1 1 unit740 1180 375 23 1030 310 35 W/K 01.917.212.1 1 unit

740 780 475 14 630 410 25 W/K 01.917.215.1 1 unit740 1000 475 19 850 410 30 W/K 01.917.216.1 1 unit740 1180 475 23 1030 410 35 W/K 01.917.217.1 1 unit

740 780 375 14 630 310 25 W/K with side door 01.917.220.1 1 unit740 1000 375 19 850 310 30 W/K with side door 01.917.222.1 1 unit740 1180 375 23 1030 310 35 W/K with side door 01.917.224.1 1 unit

740 780 475 14 630 410 25 W/K with side door 01.917.230.1 1 unit740 1000 475 19 850 410 30 W/K with side door 01.917.232.1 1 unit740 1180 475 23 1030 410 35 W/K with side door 01.917.234.1 1 unit

1210 780 375 14 630 310 50 W/K with double door 01.917.240.1 1 unit1210 1000 375 19 850 310 60 W/K with double door 01.917.241.1 1 unit1210 1180 375 23 1030 310 65 W/K with double door 01.917.242.1 1 unit

1210 780 475 14 630 410 50 W/K with double door 01.917.245.1 1 unit1210 1000 475 19 850 410 60 W/K with double door 01.917.246.1 1 unit1210 1180 475 23 1030 410 65 W/K with double door 01.917.247.1 1 unit

Cost-effective single skinned outdoorenclosure with air-to-air heat exchangerintegrated in the rear panel for installa-tion of- 19’’ And metric components- Non-standard equipment with maximum

installation widths, 535 mm and 1105mm for DIN rails and for fixing moun-ting panels

Integrated heat exchanger principle- Integration of the heat exchanger

system in the external panels- Fans and electronic control board instal-

led in the roof for maximum useful volu-me

- Optimised postioning of air entry andexit ensures lowest wind disruption ofthe airflow

- Sound pressure level, less than 55 dB(A)at 1 m distance, in accordance with ISO 7779

Front door- Closed- Standad or double door without central

bridge- With double door, right and left door

cannot be locked separately

Supply schedule, SC HEC with side door 1 Basic frame with top and bottom cover1 Side panel1 Double skinned ribbed rear panel with

internal channel plate1 Solar protection roof1 Front door, sealing on right1 Fan module with 2 fans 48 VDC, moun-

ted on the top cover, thermostat regula-ted

1 Earthing set1 Corner extrusion of basic frame1 Side door, left or right1 Partition panel

Supply schedule, SC HEC1 Basic frame with top and bottom cover2 Side panels1 Double skinned ribbed rear panel with

internal channel plate1 Solar protection roof1 Front door, sealing on right1 Fan module with 2 fans 48 VDC, moun-

ted on the top cover, thermostat regula-ted

1 Earthing set

Supply schedule, SC HEC with doubledoor

1 Basic frame with top and bottom cover2 Side panels1 Double skinned ribbed rear panel with

internal channel plate1 Solar protection roof1 Front door as double door1 Fan module with 2 fans 48 VDC, moun-

ted on the top cover, thermostat regula-ted

1 Earthing set

How suppliedEach fully assembled

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 76

Page 87: Shkaf Knurr Electronics e

by knürr

77

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

Cable Entry Panels and Troughs / Filter Box ShieldedW H D HU/U h d kg Model Order no. UP Price390 145 cable entry panel closed 01.908.605.8 1 unit490 145 cable entry panel closed 01.908.601.8 1 unit390 145 universal cable entry, foam 01.908.610.9 1 unit490 145 universal cable entry, foam 01.908.611.9 1 unit490 145 universal entry, EMC 01.908.626.9 1 unit390 145 universal entry, with brush set 01.908.612.9 1 unit490 145 universal entry, with brush set 01.908.613.9 1 unit490 145 cable entry trough 01.908.660.8 1 unit490 145 cable entry trough with filter 01.908.661.8 1 unit

- For space-saving and safe cable penetrationin tecoras Outdoor Cabinets und StreetCabinets

- Mounting in the bottom cover of thecabinets

- Mounting of the cable entry trough andfilter box underneath the vertical extru-sions, resulting in optimal space utiliza-tion

- Cable entry panels, cable entry troughs canbe interchanged with one another

- Filter box is suitable for installation of ACdistributors, overvoltage protectors, bushing-type filters and mains filters

Material- Aluminium 2 mm, colourless

chrome-plated, polished- Foam, Plastazote- EMC Metal netting fabric- Brush strips, Polyamid PA6

Supply schedule1 Closed cable entry panelor1 Universal cable entry (divided cable

entry panel) with foamor1 Universal cable entry (divided entry

panel), EMC version (option: brush setfor the divided cable entry panel)

or1 Cable entry trough (option: 1 cable entry

trough with filter box, EMC shielded, notequipped)

Each with mounting material

TEC00444_E

Metal PlinthW H D HU/U h d kg Model Order no. UP Price

640 375 0 01.914.305.1 1 unit740 375 1 01.914.303.1 1 unit

1210 375 2 01.914.307.1 1 unit640 475 0 01.914.306.1 1 unit740 475 1 01.914.304.1 1 unit

1210 475 2 01.914.308.1 1 unit

- For vandalism-proof and stable installationof tecoras outdoor Street Cabinets

MaterialStainless steel, 2 mm

FinishPowder-coatedRAL 7035 light-grey, outdoor quality inaccordance with GSB International, coarse textured

Design- Welded frame with removable front trim - The front trim can only be removed

when the door of the cabinet has alredaybeen opened

- The bolting of the plinth to the cabinet isnot externally accessible

Supply schedule1 Plinth1 Front trimMounting material for mounting the cabinet on to the plinth

TEC00245_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 77

Page 88: Shkaf Knurr Electronics e

by knürr

78

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

Fibre-Glass Reinforced Polyester PlinthW H D HU/U h d kg Model Order no. UP Price

591 375 495 0 01.914.394.1 1 unit786 375 690 1 01.914.395.1 1 unit

1116 375 1020 2 01.914.396.1 1 unit591 475 495 0 01.914.397.1 1 unit786 475 690 1 01.914.398.1 1 unit

1116 475 1020 2 01.914.399.1 1 unit

MaterialFibre-glass reinforced polyester for weather-resistant soil installations oftecoras Street Cabinets- Easily mounted- Comfortable transport weight

(max. 20 kg)- Compatible with DIN 43629 part 2,

standard plinth for cable distributor andinstrument cabinet

ColourGrey, similar to RAL 9002

Design- Self-bearing design- The front trim can only be removed

when the cabinet door has first beenopened

- The bolting of the plinth to the cabinet isnot externally accessible

Supply schedule1 Plinth, flat-packed in2 Side panels1 Rear panel1 Partitioned front panel, stabilization

rails1 Adaption set

How suppliedFlat-packed kit

Mounting Panel W H D HU/U h d kg Model Order no. UP Price535 15 01.908.751.7 1 unit535 20 01.908.752.7 1 unit535 24 01.908.753.7 1 unit535 29 01.908.754.7 1 unit535 33 01.908.755.7 1 unit

- For mounting installations for DIN rail fixingand non-standard equipment in tecorasOutdoor Cabinets and Street Cabinets withadaption options for 19’’ modular chassis’

MaterialGalvanised sheet steeel, 2 mm, polished

Supply schedule1 Mounting panel with mounting materialOption: 19’’ adapter 3 HU for fixing to themounting panel

TEC00249_E

TEC00243_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 78

Page 89: Shkaf Knurr Electronics e

by knürr

79

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

Vertical Extrusion with Mounting HolesW H D HU/U h d kg Model Order no. UP Price

15 19“ installation 01.908.001.0 1 unit20 19“ installation 01.908.002.0 1 unit24 19“ installation 01.908.003.0 1 unit29 19“ installation 01.908.005.0 1 unit33 19“ installation 01.908.006.0 1 unit

27 M metric installation 01.908.201.0 1 unit36 M metric installation 01.908.202.0 1 unit43 M metric installation 01.908.203.0 1 unit52 M metric installation 01.908.205.0 1 unit59 M metric installation 01.908.206.0 1 unit

- With mounting holes for caged nuts- For 19’’or metric installations

MaterialExtruded aluminium, polished

Supply schedule2 Vertical extrusions with mounting

material

Battery TrayW H D HU/U h d kg Model Order no. UP Price640 400 220 01.908.300.1 1 unit640 700 400 01.908.301.1 1 unit

- For safe securing and fixing of batteries intecoras Outdoor Cabinets and StreetCabinets

MaterialZinc passivated sheet steel, 2 mm

FinishPowder-coatedRAL 7035 light-grey, coarse texture

Supply schedule1 Battery tray1 Anti-slip mat of Neopren4 Fixing straps, 4 tightening straps with

polyamid Velcro fastenerMounting material

Deep StrutW H D HU/U h d kg Model Order no. UP Price

400 01.908.100.8 1 unit700 01.908.101.8 1 unit

- For the secure mounting of shortened vertical extrusions and for cable manage-ment in tecoras Outdoor Cabinets and StreetCabinets

MaterialStainless steel, 2 mm, polished

Supply schedule1 Deep strut with mounting material

TEC00327_E

TEC00330_E

TEC00333_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 79

Page 90: Shkaf Knurr Electronics e

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 80

Page 91: Shkaf Knurr Electronics e

by knürr

81

RACK SYSTEMS

Single skinned climatised and uncli-matised outdoor enclosures formounting on walls and poles andbase assembly, for installation of- 19“ and metric components- Non-standard equipment for DIN

rails and fixing mounting panels

Integrated thermal managementThe air-to-air heat exchanger inte-grated in the side panels (with StreetCabinet HEC) enables optimal cooling with the smallest installationarea with protection rating IP 55.

Outdoor Wall CaseStrong points

TEC00329

IP Protection rating- IP 55 for model with closed

door (Wall Case, Wall CaseHEC)

EMC ProtectionOptional

External covers finishPowder-coatedRAL 7035 light-grey Outdoor quality in accordancewith GSB International, coarsetexture

Load ratingStatic up to 500 N

Main unitWelded enclosure body of 3 mmchrome-plated aluminium AIMg3

External covers (only for wallenclosures with integrated heatexchanger)

- Of colourless chrome-platedaluminium AIMg3, 2 mm

- Solar protection roof, screwed/bolted

- All bolting and connection elements on the inside

Door- Door closed or ventilated- Of colourless chrome-plated

aluminium AIMg3, 2 mm- Double skinned door model for

enclosures with high EMC pro-tection rating

- Door stop on right or left- Swing handle for profile half

cylinder with saw protection- Double interlocking system- Hidden hinges- Door hinge to maximum

opening angle of 150º

Outdoor Wall CaseTechnical data

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 81

Page 92: Shkaf Knurr Electronics e

by knürr

82

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

Outdoor Wall CaseW H D HU/U h d kg Model Order no. UP Price405 400 250 340 210 01.915.002.1 1 unit485 400 250 340 210 01.915.004.1 1 unit405 600 250 540 210 01.915.006.1 1 unit485 600 250 540 210 01.915.008.1 1 unit485 600 345 540 305 01.915.010.1 1 unit585 600 345 540 305 01.915.012.1 1 unit485 800 250 740 210 01.915.014.1 1 unit485 800 345 740 305 01.915.016.1 1 unit585 800 345 740 305 01.915.018.1 1 unit

TEC00329_E

Cost-effective outdoor wall enclosure forinstallation of- Non-standard equipment with installati-

on widths of 305 to 485 mm for DIN railsand fixing mounting panels

- 19’’ Components (only for enclosurewidth 585 mm)

Supply schedule1 Wall case with mounting straps for

mounting on the wall1 Front door, closed,

stop on left side1 Closed cable entry panel in the bottom 1 Mounting panel of 2 mm zinc passivated

sheet steel, polished, mounted on therear side

1 Earthing set

How suppliedFully assembled

Outdoor Wall Case HECW H D HU/U h d kg Specific cooling wattage Order no. UP Price550 700 345 540 290 35 W/K 01.914.500.1 1 unit650 700 345 540 290 35 W/K 01.914.502.1 1 unit650 700 445 540 390 40 W/K 01.914.510.1 1 unit550 900 345 740 290 40 W/K 01.914.504.1 1 unit650 900 345 740 290 40 W/K 01.914.506.1 1 unit650 900 445 740 390 45 W/K 01.914.508.1 1 unit

TEC00150_E

Double skinned outdoor wall case with air-to-air heat exchanger integrated in the sidepanels for installation of - 19“ Components (for cabinet width 650 mm)- Non-standard equipment with installation

widths of 305 to 485 mm for DIN rails andfixing of mounting panels

Integrated heat exchanger principle- Integration of the heat transfer system

in the side panels- Fans and electronic control board instal-

led in the roof for maximum useful volu-me

- Optimised postioning of air entry andexit ensures lowest wind disruption ofthe airflow

- Sound pressure level, less than 55 dB(A)at 1 m distance, in accordance with ISO 7779

Supply schedule1 Wall case2 Double skinned ribbed side panels with

internal channel plate 1 Solar protection roof1 Front door, closed,

stop on right1 Fan module with 2 fans 48 VDC,

mounted on the cover, thermostat regulated

1 Closed cable entry panel in the bottom 1 Earthing set

How suppliedFully assembled

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 82

Page 93: Shkaf Knurr Electronics e

by knürr

83

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

Wall Mounting for Wall Case HECW H D HU/U h d kg Model Order no. UP Price550 700 350 01.914.488.1 1 unit650 700 350 01.914.489.1 1 unit650 700 450 01.914.490.1 1 unit550 900 350 01.914.491.1 1 unit650 900 350 01.914.492.1 1 unit650 900 450 01.914.493.1 1 unit

TEC00155_E

- Wall mounting with/without pole support

Material- Frame, sheet steel and case extrusion of

steel- Console, stainless steel, 1.5 mm

Option- Pole mounting for fixing to the frame of

the wall mounting for pole diameters 50,100, 150 and 200 mm

- Material, stainless steel- Supply schedule: 2 clamps, 1 rear panel

for the frame, mounting material

Supply schedule1 Frame1 Console, consisting of 2 side panels1 Front trim with fastener1 Base cover

How suppliedFlat-packed kit

Battery TrayW H D HU/U h d kg Model Order no. UP Price650 445 285 01.908.309.7 1 unit

TEC00361_E

- For safe securing and fixing of batteries intecoras Outdoor Wall Cases

- For mounting on the 19’’ installation

MaterialZinc passivated sheet steel, 2 mm, polished

Supply schedule1 Battery tray2 Chassis runners1 Anti-slip mat made of NeoprenMounting material

19“ AdapterW H D HU/U h d kg Model Order no. UP Price

700 450 11 330 01.914.840.7 1 unit900 450 15 330 01.914.841.7 1 unit

TEC00362_E

- With mounting holes for caged nuts

MaterialAluminium, 2 mm, polished

Supply schedule2 Side panels with integrated 19’’

mounting holesMounting bracketMounting material

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 83

Page 94: Shkaf Knurr Electronics e

by knürr

84

RACK SYSTEMS

Individual configuration- Wide product range of heat

exchangers and cooling unitswith extremely good output /installation size and noiseemmision configuration

- Design and customizing whiletaking all influencing factorsinto consideration (e.g. installation equipment andconfiguration conditions)

- High thermal efficiency withspecialised heat transfersystems

Thermal management adaptioncapability Variable cabinet panels enableboth convection cooling and ther-mal isolation

Optimised installationCompact design, space-savingand service-friendly integrated inthe door

TestsSimulations, trials and tests inour own thermal laboratory

4

3

2

1

tecoras Thermal ManagementStrong points

TEC00002_E1

TEC00040_E2

TEC00087_E3

TEC00279_E4

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 84

Page 95: Shkaf Knurr Electronics e

by knürr

85

RACK SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weight

Final digit of order number:.1 = RAL 7035 light-grey

Air-to-Air Heat Exchanger HP HEXW H D kg Model Specific cooling wattage Order no. UP Price465 840 90 11 DC 48 V 80 W/K 01.910.813.0 1 unit465 1030 90 12 DC 48 V 100 W/K 01.910.814.0 1 unit465 1030 150 13 DC 48 V 180 W/K 01.910.815.0 1 unit

TEC00015_E

- High performance air-to-air heat exchangerfor door installation in tecoras OutdoorCabinets

Material- Enclosure: aluminium, 1.5 mm- Heat exchanger: plastic

(UL 94 V2), 0.5 mm

Principle- Air-to-air heat exchanger with micro-

processor control- Heat exchanger made of plastic- Mounting with adapter bracket on the

inside of the door- Speed-controlled fan, resulting in noise

level reduction

Technical data- Supply voltage, 48 VDC- Sound pressure level ‹ 55 dB(A) at a

distance of 1 m, in accordance with ISO7779, up to 100 W/K specific coolingwattage

- Sustained use temperature - 40 to +55°C

- Protection rating IP 55 in accordancewith IEC 60529 in the cabinet

- Alarm outputs via Sub-D-plug: powerfailure, fan failure

Supply schedule1 Heat exchanger1 Connector for DC input

Control Cabinet, Heating Unit (HVL)W H D HU/U h d kg Model Order no. UP Price108 85 139 150 01.910.900.9 1 unit135 85 182 300 01.910.901.9 1 unit135 85 182 400 01.910.902.9 1 unit145 85 240 600 01.910.903.9 1 unit

TEC00335_E

Technical dataSupply voltage 230 VAC/50(60) Hz, Axial fan: air throughput 35 m3/hwith 150 W, from 300 W 108 m3/hThermostat: temperature settingfrom 0 to 60° CHeating element protection with temperature monitor in the event of fan failureProtection rating IP 20

Supply schedule1 Heating fan, 230 VAC / 50(60) Hz1 Thermostat with contact break1 Connector GST 18 (Wieland),

three-pole, for AC input1 Mounting panelMounting material

How suppliedFully assembled

Cooling Unit (ACU)W H D Model Cooling wattage Order no. UP Price410 640 155 AC 230 V / 50 (60 Hz) 500 W 01.910.503.0 1 unit410 840 155 AC 230 V / 50 (60 Hz) 800 W 01.910.505.0 1 unit410 1030 155 AC 230 V / 50 (60 Hz) 1200 W 01.910.507.0 1 unit410 1030 155 AC 230 V / 50 (60 Hz) 1800 W 01.910.509.0 1 unit

- High performance cooling unit for doorinstallation in tecoras Outdoor Cabinets

MaterialEnclosure: aluminium, 1.5 mm

Principle- High performance cooling unit with

microprocessor control- Chloroflurocarbon-free refrigerant

R 134 a- Mounting with adapter bracket on the

inside of the door- Speed-controlled fan, resulting in noise

level reduction - Condensation discharged to the outside

for safety purposes

Technical data- Supply voltage 230 VAC / 50(60) Hz- Sound pressure level ‹ 55 dB(A) at a

distance of 1 m, in accordance with ISO7779, up to 1200 W cooling wattage

- Sustained use temperature max. - 33 to+ 45°C

- Protection rating IP 55 in accordancewith IEC 60529 in the cabinet

- Alarm outputs via Sub-D-plug: powerfailure, fan failure, compressor failure

Supply schedule1 Cooling unit1 Unit connector for AC input

TEC00016_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 85

Page 96: Shkaf Knurr Electronics e

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 86

Page 97: Shkaf Knurr Electronics e

Strong Points and technical details Page 88Product Page 89Accessories Page 90

CS2007 19“ Heavy Duty Chassis

CS2007

by knürr

87

ELECTRONIC ENCLOSURES

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 87

Page 98: Shkaf Knurr Electronics e

by knürr

88

ELECTRONIC ENCLOSURES

The fully enclosed chassis ensu-res protection from contact withlive elements.Heat transfer is guaranteed viathe vent slots in the top and bot-tom covers.

Mounting of heavy duty installati-ons is enabled with the high loadrating of the robust chassisstructure.

2

1 Two stable, ergonomically sha-ped handles provide conveniencefor installing, upgrading andcarrying the chassis, and protec-tion of protrusive front elements.

3

19” Heavy Duty Chassis CS2007Strong points

CS00034_E1

CS00038_E2

CS00037_E3

Construction- Aluminium extrusion frame

construction, 3 mm aluminiumfront panel

- Enclosed- Variable mounting options for

installations in height, widthand depth by using T-slotspring nut system

External dimensionsIn compliance with IEC 297(88.1; 132.5; 177.0; 221.4; 265.9 mm)- Width 19” chassis 482.6 mm- Depth 350, 450, 550 mm

Material- Aluminium extrusion- Front panel 3 mm- Rear panel 2 mm- Covers, sheet steel, 0.75 mm- Handle, die-cast aluminium

Finish- Aluminium extrusions, yellow

chrome-plated- Front panel, powder-coated,

light-grey, smooth, RAL 7035- Rear panel, yellow chrome-

plated- Covers, yellow chrome-plated- Handles, powder-coated,

grey-blue texture RAL 5008

Static load rating- 50-80 N per HU

19” Chassis CS2007Technical data

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 88

Page 99: Shkaf Knurr Electronics e

by knürr

89

CS00027_E

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, CRS = Cable routing set, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weightd = Installation depth, h = Installation height

19” Chassis CS2007 with CoverTop and bottom cover with perforationW H D HU/U h c d kg Model Order no. UP Price

88.1 2 84.1 53.9 350 4.7 02.007.540.9 1 unit132.5 3 128.1 98.3 350 5.2 02.007.541.9 1 unit177.0 4 173.0 142.8 350 5.8 02.007.542.9 1 unit221.4 5 217.4 187.2 350 6.3 02.007.543.9 1 unit265.9 6 261.9 230.9 350 6.9 02.007.544.9 1 unit

177.0 4 173.0 142.8 450 6.9 02.007.550.9 1 unit221.4 5 217.4 187.2 450 7.5 02.007.551.9 1 unit265.9 6 261.9 230.9 450 8.1 02.007.552.9 1 unit310.3 7 306.3 276.1 450 8.7 02.007.553.9 1 unit

177.0 4 173.0 142.8 550 8.0 02.007.558.9 1 unit221.4 5 217.4 187.2 550 8.6 02.007.559.9 1 unit265.9 6 261.9 230.9 550 9.2 02.007.560.9 1 unit310.3 7 306.3 276.1 550 9.8 02.007.561.9 1 unit354.8 8 350.8 320.6 550 10.4 02.007.562.9 1 unit

Standard features1 Front panel4 Depth extrusions2 Connecting extrusions, vertical, 2-piece2 Connecting extrusions, horizontal,

2-piece2 Vertical extrusions1 Mounting panel2 Side plates1 Cover plate, perforated1 Bottom cover, perforated2 HandlesMounting material

CS00034_E

Finish- Mounting panel, polished- Depth uprights (extrusions), yellow

chrome-plated- Covers, yellow chrome-plated- Front panel, powder-coated, light-grey,

smooth, RAL 7035- Handles, powder-coated

grey-blue, textured, RAL 5008

How suppliedFlat-packed kit

Second Mounting LevelW H D HU/U Model Order no. UP Price

6 02.007.304.9 1 unit8 02.007.306.9 1 unit

Using 2 additional vertical extrusions, asecond level can be created. This serves forfixing a mounting panel and other installation components.

FinishYellow chrome-plated

How supplied2 Vertical extrusionsMounting material

CS00031_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 89

Page 100: Shkaf Knurr Electronics e

by knürr

90

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, CRS = Cable routing set, ESD = ESD version1 HU / U = Standard height unit (unit) = 44.45 mm, UP = Unit of packaging, kg = Weightd = Installation depth, h = Installation height

Mounting PanelW H D HU/U A B Model Order no. UP Price

350 250 403 2.007.317.9 1 unit450 350 403 2.007.318.9 1 unit550 450 403 2.007.317.9 1 unit

- For mounting components- Width 403 mm

Material2 mm aluminium sheet, polished

Supply schedule1 Mounting panelMounting material

Rear PanelW H D HU/U Model Order no. UP Price403 44.1 2 2.007.324.9 1 unit403 88.5 3 2.007.325.9 1 unit403 133.0 4 2.007.326.9 1 unit403 177.4 5 2.007.327.9 1 unit403 221.9 6 2.007.328.9 1 unit403 266.3 7 2.007.329.9 1 unit403 310.8 8 2.007.330.9 1 unit

- Width 403 mm

Material2 mm aluminium sheet, yellow chrome-plated

Supply schedule1 Rear panel2 Mounting extrusionsMounting material

CS00014_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 90

Page 101: Shkaf Knurr Electronics e

Strong Points and technical details Page 92Product Page 94Accessories Page 106

Front panels Page 138

eurocard 19“ Modular Chassis

eurocard

by knürr

91

ELECTRONIC ENCLOSURES

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 91

Page 102: Shkaf Knurr Electronics e

by knürr

92

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

Installation of connectors inaccordance with DIN 41612,backplanes also optional.

Cross extrusion offset (in 10-mm increment).Application on chassis runners ismade possible for modular chas-sis’ with higher installationweight by using lower main unitheights.

Rear side mounting of push/plug-in modules with correspondingcross extrusion positioning.

Telescopic rail mounting alsopossible.

Mixed construction can be imple-mented with (Eurocards, DoubleEurocards, cassettes etc.) modu-lar chassis subdivider.

Horizontal installation of DoubleEurocards in 3 HU modular chas-sis’ can be implemented by usinga mounting kit.

6

5

4

3

2

1

Eurocard Modular ChassisStrong points

EUR80003_E3 EUR80004_E4

EUR80001_E1 EUR80002_E2

EUR80005_E5 EUR80006_E6

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 92

Page 103: Shkaf Knurr Electronics e

by knürr

93

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

EUR20010_E

EUR20009_E

Side panel

Cross extrusion, front

Cross extrusion, rear, with push/plug-in mounting in accordance with DIN 41612

Label strips, front

Label strips, rear

Hexagonal screws M 4 x 12 withcontact washer

6

5

4

3

2

1

Eurocard Modular ChassisTechnical data

465

482.6

Eurocard modular chassis in accordance withIEC 297-3/4

Material / Finish- Side panels, aluminium sheet 2 mm- Cross extrusions,

extruded aluminium - 19“ Adapter, integrated in the side panel

External dimensions in accordance withIEC 297-3- Width 448 mm,

- via 19“ adapter, 482.6 mm- Height/H 3 HU (132.5 mm)

6 HU (265.8 mm)- Depths 180, 240, 300 and 360 mm

Installation area- Width 84 HP (horizontal pitch)- Height/h 3 HU (112.5)- Nominal depth 160, 220, HU (245.8)

280 mm, additional mounting levelspossible on the 10 mm increment

Installation in 19“ cabinets and enclosures- Telescopic rail mounting possible - With chassis rails

How suppliedFlat-packed kit

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 93

Page 104: Shkaf Knurr Electronics e

by knürr

94

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

Eurocard 19” Economy Modular ChassisFor mounting plug carriers or backplanesW H D HU/U h d kg Model / Nominal depth Order no. UP Price84 HP 180 3U 112.5 160 02.365.007.9 1 unit84 HP 240 3U 112.5 160/220 02.365.008.9 1 unit84 HP 300 3U 112.5 160/220/280 02.365.009.9 1 unit84 HP 360 3U 112.5 160/220/280 02.365.010.9 1 unit

84 HP 180 6U 245.9 160 02.366.010.9 1 unit84 HP 240 6U 245.9 160/220 02.366.011.9 1 unit84 HP 300 6U 245.9 160/220/280 02.366.012.9 1 unit84 HP 360 6U 245.9 160/220/280 02.366.013.9 1 unit

FinishSide panels, chrome-plated, whiteCross extrusions, aluminiumAluminium extrusions, polished

Supply schedule2 Side panels2 Cross extrusions, front2 Cross extrusions, rear4 Label strips1 Cross extrusion, rear, centre

(only with model 6U)Mounting material

Eurocard 19” Economy Modular ChassisWith integrated plug carriersW H D HU/U h d kg Model / Nominal depth Order no. UP Price84 HP 180 3U 112.5 160 02.365.017.9 1 unit84 HP 240 3U 112.5 160/220 02.365.018.9 1 unit84 HP 300 3U 112.5 160/220/280 02.365.019.9 1 unit84 HP 360 3U 112.5 160/220/280 02.365.020.9 1 unit

84 HP 180 6U 245.9 160 02.366.020.9 1 unit84 HP 240 6U 245.9 160/220 02.366.021.9 1 unit84 HP 300 6U 245.9 160/220/280 02.366.022.9 1 unit84 HP 360 6U 245.9 160/220/280 02.366.023.9 1 unit

- For mounting connectors in accordance with DIN 41612

FinishSide panels, chrome-plated, whiteCross extrusion, aluminiumAluminium extrusion, polished

Supply scheduleSame basic equipping as Eurocard formounting plug carriers or backplanesHowever:Cross extrusions, rear with integrated Z rails for mounting connectors in accor-dance with DIN 416121 Cross extrusion, rear, centre

(only with model 6U)

Eurocard TrimWith / without handleW H D HU/U h d kg Model Order no. UP Price

3U without handle 02.350.100.9 2 unit6U without handle 02.365.101.9 2 unit

3U with handle 02.350.110.9 2 unit6U with handle 02.365.111.9 2 unit

- Front view of the 19’’ modular chassis

FinishTrims anodised, natural

EUR20007_E

EUR20008_E

EUR20010_E

EUR20005_E

EUR20004_E

Note:Other models available on request!

Supply schedule2 Trims2 Handles (depending on model)

Accessories on page 106

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 94

Page 105: Shkaf Knurr Electronics e

by knürr

95

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

Eurocard Cover Plate, PerforatedW H D HU/U h d kg Mod. chassis nom. depth Order no. UP Price84 HP 160 180 02.365.040.9 1 unit84 HP 220 240 02.365.041.9 1 unit84 HP 280 300 02.365.042.9 1 unit84 HP 340 360 02.365.043.9 1 unit

EUR20006_E

- For covering the installation area- For modular chassis Eurocard with nominal

depths 160/220/280

Supply schedule1 Cover plate

Eurocard with Extrusion Side PanelsFor expansion cards with nominal depths 160 / 220 / 280W H D HU/U h d Pr. circ. board nom. depth Order no. UP Price

3U 180 112.5 160 02.365.021.9 1 unit3U 240 112.5 160 / 220 02.365.023.9 1 unit6U 180 245.9 160 02.366.022.9 1 unit6U 240 245.9 160 / 220 02.366.024.9 1 unit

Standard featuresEurocard economy for backplanes, howe-ver side panels of extruded aluminium

NoteNo additional trims required

Note:Other models available on request!

Accessories on page 106

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 95

Page 106: Shkaf Knurr Electronics e

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 96

Page 107: Shkaf Knurr Electronics e

Strong Points and technical details Page 98Product Page 100Accessories Page 106

Front panels Page 138

chasseleon Bench Case / 19“ Chassis

chasseleon

by knürr

97

ELECTRONIC ENCLOSURES

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 97

Page 108: Shkaf Knurr Electronics e

by knürr

98

ELECTRONIC ENCLOSURES

Flexible application, as benchcase or 19” chassis, withstraightforward remodelling withlow mounting expense.

Heat discharge tailored to theapplication in three variants:Type 1: Diagonal

Vent slots in bottom cover and rear panel

Type 2: HorizontalVent slots in the side andrear panel

Type 3: VerticalVent slots in the top andbottom cover, and rearpanel

Easy access with the 19” chassisvariants via chassis rails or teles-copic rails in the 19” cabinet orenclosure.

Optimal shielding of the remov-able covers with EMC spring.

Defined bonding of the enclosurefront and rear panels via contactembossing on the adapters.

Flexible usage by connecting two or more enclosures to onetower.

6

5

4

3

2

1

chasseleon Bench Case / 19“ Chassis Strong points

CHA00181_E Type 12

CHA00180_E Type 22

CHA00231_E1

CHA00232_E6

CHA179_E Type 32

CHA80181_E4

CHA00227_E5

CHA00257_E3

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 98

Page 109: Shkaf Knurr Electronics e

by knürr

99

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

Bench cases and 19” chassis in accordance withIEC 297-3- Aluminium extrusion design of

cross and depth extrusions- Top and bottom plate, 0.75 mm

sheet steel, zinc passivated- Rear panel,

2 mm aluminium plate- Handle and adapter, die-cast

aluminium

Installation area in compliancewith IEC 297-3- Height 2, 3, 4, 6 and 7 HU- Width 84 HP

Configuration- Plastic feet- Chassis with 19” adapters,

optional with telescopic rails

TestsEMC measuring in accordancewith - MIL-STD 285 (10 KHz–30 MHz)- VG 95373 part 15

(30 MHz–1 GHz)

Constructive structuringThe enclosure structure consistsof 2 extruded aluminium sidepanels with integrated hole pat-tern and T-slots, in addition to 4extruded aluminium cross extru-sions.The basic outfitting includessheet steel covers and die-castaluminium elements.A number of variation and expansion options make thechasseleon enclosure adaptableto every requirement.

FinishCovers, side extrusions,powder-coated, textured, light-grey, RAL 7035Cross extrusions, adapter, handles, powder-coated, textu-red, grey-blue, RAL 5008

How suppliedFlat-packed kit

chasseleon Bench Case / 19“ Chassis Technical data

chasseleonW H D HU/U w h d kg ND Order no. UP Price448.0 89 240.7 2 427.2 69 235.2 2.7 220448.0 89 300.7 2 427.2 69 298.2 3.4 280448.0 89 400.7 2 427.2 69 395.2 4.6 380448.0 89 5007 2 427.2 69 495.2 5.8 480

448.0 132.5 240.7 3 427.2 112.5 235.2 3.1 220448.0 132.5 300.7 3 427.2 112.5 295.2 3.8 280448.0 132.5 400.7 3 427.2 112.5 395.2 5.0 380448.0 132.5 500.7 3 427.2 112.5 495.2 6.2 480

448.0 177 240.7 4 427.2 157 235.2 3.1 220448.0 177 300.7 4 427.2 157 295.2 3.8 280448.0 177 400.7 4 427.2 157 395.2 5.0 380448.0 177 500.7 4 427.2 157 495.2 6.2 480

448.0 265.9 240.7 6 427.2 245.9 235.2 4.4 220448.0 265.9 300.7 6 427.2 245.9 295.2 5.1 280448.0 265.9 400.7 6 427.2 245.9 395.2 6.3 380448.0 265.9 500.7 6 427.2 245.9 495.2 7.5 480

448.0 310.3 240.7 7 427.2 290.3 235.2 4.8 220448.0 310.3 300.7 7 427.2 290.3 295.2 5.5 280448.0 310.3 400.7 7 427.2 290.3 395.2 6.7 380448.0 310.3 500.7 7 427.2 290.3 495.2 7.9 480

CHA00262_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 99

Page 110: Shkaf Knurr Electronics e

by knürr

100

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

chasseleon 19” ChassisWithout coverW H D HU/U h d kg Nominal depth Order no. UP Price84 HP 240.7 2U 69 235.2 2.7 160 02.320.332.1 1 unit.84 HP 300.7 2U 69 295.2 3.4 160/220 02.320.392.1 1 unit

84 HP 240.7 3U 112.5 235.2 3.1 160 02.320.333.1 1 unit84 HP 300.7 3U 112.5 295.2 3.8 160/220 02.320.393.1 1 unit84 HP 400.7 3U 112.5 395.2 5 160/220/280 02.320.163.1 1 unit

84 HP 300.7 4U 157 295.2 3.8 160/220 02.320.394.1 1 unit84 HP 400.7 4U 157 395.2 5 160/220/280 02.320.166.1 1 unit84 HP 500.7 4U 157 495.2 6.2 160/220/280 02.320.174.1 1 unit

84 HP 300.7 6U 157 295.2 5.1 160/220 02.320.396.1 1 unit84 HP 400.7 6U 157 395.2 6.3 160/220/280 02.320.166.1 1 unit84 HP 500.7 6U 157 495.2 7.5 160/220/280 02.320.176.1 1 unit

FinishSide extrusions, adapter, front,powder-coated, textured,RAL 7035, light-greyCross extrusions, adapter rear, handles,powder-coated, textured,RAL 5008 grey-blue

Supply schedule2 Side panels2 Cross extrusions, front2 Cross extrusions, rear2 Adapters, front2 Adapters, rear2 Handles2 Cover extrusions (with 4/6HU)Mounting materialRAL 5008, grey-blue

chasseleon 19” ChassisWith coverW H D HU/U h d kg Nominal depth Order no. UP Price84 HP 240.7 2U 68 235.2 2.7 160 02.320.132.1 1 unit84 HP 300.7 2U 68 295.2 3.4 160/220 02.320.192.1 1 unit

84 HP 240.7 3U 112.5 235.2 3.1 160 02.320.133.1 1 unit84 HP 300.7 3U 112.5 295.2 3.8 160/220 02.320.193.1 1 unit84 HP 400.7 3U 112.5 495.2 6.2 160/220/280 02.320.153.1 1 unit

84 HP 300.7 4U 157 295.2 3.8 160/220 02.320.194.1 1 unit84 HP 400.7 4U 157 395.2 5 160/220/280 02.320.154.1 1 unit84 HP 500.7 4U 157 495.2 6.2 160/220/280 02.320.214.1 1 unit

84 HP 240.7 6U 245.9 235.2 4.4 160 02.320.136.1 1 unit84 HP 330.7 6U 245.9 295.2 5.1 160/220/280 02.320.196.1 1 unit84 HP 500.7 6U 245.9 495.2 7.5 160/220/280 02.320.216.1 1 unit

84 HP 300.7 7U 290.3 295.2 5.5 160/220 02.320.197.1 1 unit84 HP 400.7 7U 290.3 395.2 6.7 160/220/280 02.320.157.1 1 unit84 HP 500.7 7U 290.3 495.2 7.9 160/220/280 02.320.217.1 1 unit

CHA00259_E

CHA00215_E

FinishCovers, additional,powder-coated, textured,RAL 7035, light-grey

Supply scheduleBasic equipping as chasseleonwithout cover, additional:1 Top cover1 Bottom cover with vent slots4 Seals1 Rear panel with vent slots4 Cover extrusions (with 7HU)

Note:Other configurations and models availableon request!

Accessories on page 106

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 100

Page 111: Shkaf Knurr Electronics e

by knürr

101

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight Note:

Other configurations and models availableon request!

Accessories on page 106

ELECTRONIC ENCLOSURES

CHA00220_E

chasseleon 19” ChassisShielded versionW H D HU/U h d kg Model Order no. UP Price83 HP 240.7 3U 112.5 235.2 3.1 160 02.327.373.1 1 unit83 HP 300.7 3U 112.5 295.2 3.8 160/220 02.327.383.1 1 unit

83 HP 400.7 4U 157 395.2 5 160/220/280 02.327.394.1 1 unit83 HP 500.7 4U 157 495.2 6.2 160/220/280 02.327.404.1 1 unit

83 HP 240.7 6U 245.9 235.2 4.4 160 02.327.376.1 1 unit83 HP 300.7 6U 245.9 295.2 5.1 160/220 02.327.386.1 1 unit

FinishSide extrusions, adapter front,powder-coated, textured,RAL 7035, light-greyCross extrusions, adapter rear, handles,powder-coated, textured,RAL 5008 grey-blueCovers, additional,powder-coated, textured,RAL 7035, light-grey

Supply scheduleBasic equipping as chasseleonwithout cover, additional:2 Side closings1 Top cover1 Bottom cover1 EMC seal1 Rear panel2 Cover extrusions (with 4/6 HU)4 EMC seals

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 101

Page 112: Shkaf Knurr Electronics e

by knürr

102

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

chasseleon Bench EnclosureWith vent slots in bottom cover and rear panelW H D HU/U h d kg Model Order no. UP Price84 HP 240.7 2U 69 235.2 2.7 160 02.310.122.1 1 unit84 HP 400.7 2U 69 395.2 4.6 160/220/280 02.310.142.1 1 unit84 HP 500.7 2U 69 495.2 5.8 160/220/280 02.310.202.1 2 units

84 HP 240.7 3U 112.5 235.2 3.1 160 02.310.123.1 1 unit84 HP 300.7 3U 112.5 295.2 3.8 160/220 02.310.183.1 1 unit84 HP 400.7 3U 112.5 395.2 5 160/220/280 02.310.143.1 1 unit84 HP 500.7 3U 112.5 495.2 6.2 160/220/280 02.310.203.1 1 unit

84 HP 240.7 4U 157 235.2 3.1 160 02.310.124.1 1 unit84 HP 300.7 4U 157 295.2 3.8 160/220 02.310.184.1 1 unit84 HP 400.7 4U 157 395.2 5 160/220/280 02.310.144.1 1 unit84 HP 500.7 4U 157 495.2 6.2 160/220/280 02.310.204.1 1 unit

84 HP 300.7 6U 245.9 295.2 5.1 160/220 02.310.186.1 1 unit84 HP 400.7 6U 245.9 395.2 6.3 160/220/280 02.310.146.1 1 unit84 HP 500.7 6U 245.9 492.2 7.5 160/220/280 02.310.206.1 1 unit

84 HP 400.7 7U 290.3 395.2 6.7 160/220/280 02.310.147.1 1 unit84 HP 500.7 7U 290.3 495.2 7.9 160/220/280 02.310.207.1 1 unit

CHA00262_E

CHA00262_E

CHA00192_E

Supply schedule2 Side extrusions2 Cross extrusions, front2 Cross extrusions, rear2 Adapters, front2 Adapters, rear2 Handles1 Top cover1 Bottom cover with vent slots4 Seals1 Rear panel with vent slotsCover extrusions (2 pieces at 4/6HU; 4pieces at 7HU)2 Screw-on feet2 Tilt feetMounting material

FinishCovers, side extrusionspowder-coated, texturedRAL 7035, light-greyCross extrusions, adapter, handles,powder-coated, texturedRAL 5008, grey-blue

chasseleon Bench EnclosureWith vent slots in side and rear panelW H D HU/U h d kg Model Order no. UP Price84 HP 240.7 3U 112.5 235.2 3.1 160 02.311.123.1 1 unit84 HP 300.7 3U 112.5 295.2 3.8 160/220 02.311.183.1 1 unit84 HP 400.7 3U 112.5 395.2 5 160/220/280 02.311.143.1 1 unit

84 HP 300.7 4U 157 295.2 3.8 160/220 02.311.184.1 1 unit84 HP 400.7 4U 157 395.2 5 160/220/280 02.311.144.1 1 unit84 HP 500.7 4U 157 495.2 6.2 160/220/280 02.311.204.1 1 unit

84 HP 300.7 6U 245.9 295.2 5.1 160/220 02.311.186.1 1 unit84 HP 400.7 6U 245.9 395.2 6.3 160/220/280 02.311.146.1 1 unit84 HP 500.7 6U 245.9 495.2 7.5 160/220/280 02.311.206.1 1 unit

84 HP 400.7 7U 290.3 395.2 6.7 160/220/280 02.311.147.1 1 unit84 HP 500.7 7U 290.3 495.2 7.9 160/220/280 02.311.207.1 1 unit

CHA00191_E

FinishCovers, side extrusions,powder-coated, textured,RAL 7035, light-greyCross extrusions, adapter, handles,powder-coated, textured,RAL 5008, grey-blue

Supply scheduleBasic equipping as above,however:Side extrusions with vent slotsBottom cover closed

Note:Other configurations and models availableon request!

Accessories on page 106

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 102

Page 113: Shkaf Knurr Electronics e

by knürr

103

Note:Other configurations and models availableon request!

Accessories on page 106

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

CHA00262_E

FinishCovers, side extrusions,powder-coated, textured,RAL 7035, light-greyCross extrusions, adapter, handles,powder-coated, textured,RAL 5008, grey-blue

chasseleon Bench EnclosureWith vent slots in top and bottom cover and rear panelW H D HU/U h d kg Model Order no. UP Price84 HP 240.7 3U 112.5 235.2 3.1 160 02.311.133.1 1 unit84 HP 300.7 3U 112.5 295.2 3.8 160/220 02.311.193.1 1 unit84 HP 400.7 3U 112.5 395.2 5 160/220/280 02.311.153.1 1 unit84 HP 500.7 3U 112.5 495.2 6.2 160/220/280 02.311.213.1 1 unit

84 HP 300.7 4U 157 295.2 3.8 160/220 02.311.194.1 1 unit84 HP 400.7 4U 157 395.2 5 160/220/280 02.311.154.1 1 unit84 HP 500.7 4U 157 495.2 6.2 160/220/280 02.311.214.1 1 unit

84 HP 300.7 6U 245.9 295.2 5.1 160/220 02.311.196.1 1 unit84 HP 400.7 6U 245.9 395.2 6.3 160/220/280 02.311.156.1 1 unit84 HP 500.7 6U 245.9 495.2 7.5 160/220/280 02.311.216.1 1 unit

CHA00190_E

Supply schedule2 Side extrusions2 Cross extrusions, front2 Cross extrusions, rear2 Adapters, front2 Adapters, rear2 Handles1 Top cover with vent slots1 Bottom cover with vent slots4 Seals1 Rear panel with vent slotsCover extrusions (at 4/6HU)2 Screw-on feet2 Tilt feetMounting material

chasseleon 19” AdapterW H D HU/U h d kg Model Order no. UP Price

3 Standard 02.320.843.1 1 unit3 EMC 02.327.843.1 1 unit

4 Standard 02.320.844.1 1 unit4 EMC 02.327.844.1 1 unit

6 Standard 02.320.846.1 1 unit6 EMC 02.327.846.1 1 unit

CHA00248_E

CHA00249_E

- Handle for converting a bench enclosure to a 19” chassis

Finish- Adapter, powder-coated RAL 7035- Handle, powder-coated RAL 5008

Handle for 19“ ChassisW H D HU/U h d kg Model Order no. UP Price

3 Standard 02.310.843.1 1 unit3 EMC 02.317.843.1 1 unit

4 Standard 02.310.844.1 1 unit4 EMC 02.317.844.1 1 unit

6 Standard 02.310.846.1 1 unit6 EMC 02.317.846.1 1 unit

- Handle for converting a 19” chassis toa bench enclosure

FinishPowder-coated RAL 5008

How suppliedPacked in pairs with mounting material

How suppliedPacked in pairs with mounting material

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 103

Page 114: Shkaf Knurr Electronics e

by knürr

104

ELECTRONIC ENCLOSURES

chasseleon Front Panel, EMCW H D HU/U h d kg Model Order no. UP Price83 HP 2 U 02.317.002.9 1 unit83 HP 3 U 02.317.003.9 1 unit83 HP 4 U 02.317.004.9 1 unit83 HP 6 U 02.317.005.9 1 unit83 Hp 7 U 02.317.006.9 1 unit

CHA00251_E

- For shielded model

FinishFront side natural colour anodisedRear side chrome-plated

Supply schedule1 Front panel, EMC

chasseleon Rear Panel with Vent SlotsW H D HU/U h d kg Model Order no. UP Price84 HP 2 U 02.310.002.1 1 unit84 HP 3 U 02.310.003.1 1 unit84 HP 4 U 02.310.004.1 1 unit84 HP 6 U 02.310.006.1 1 unit84 HP 7 U 02.310.007.1 1 unit

CHA00250_E

- For 19” chassis without cover

FinishPowder-coated, light-grey, textured RAL 7035

Supply schedule1 Rear panelMounting material

chasseleon Connecting ExtrusionsW H D HU/U ND Model Order no. UP Price

220 02.310.018.1280 02.310.019.1380 02.310.020.1480 02.310.021.1

CHA00231_E

- For connecting enclosures of equal depth toa tower

FinishPowder-coated, light-grey,textured RAL 7035

Supply schedule2 Connecting extrusions Mounting material

Accessories on page 106Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 104

Page 115: Shkaf Knurr Electronics e

by knürr

105

Accessories on page 106

ELECTRONIC ENCLOSURES

chasseleon Telescopic Rails W H D HU/U h d kg Load rating (N) Order no. UP Price

505 250 02.310.250.9 1 unit605 200 02.310.251.9 1 unit705 150 02.310.252.9 1 unit

CHA00230_E

- For chasseleon chassis’ 3 - 7 HU, ND 200 - 480 mm

chasseleon Universal Chassis RailsW H D HU/U h d kg Model Model. UP Price

360 303.6 02.310.258.9 1 unit460 403.6 02.310.259.9 1 unit560 503.6 02.310.260.9 1 unit560 603.6 02.310.261.9 1 unit

TEL 00157_E

MEC00029_E

- For installation in 19’’ racks and enclosure Supply schedule1 Pair of chassis railsMounting material

T

Supply schedule1 Pair of telescopic railsMounting material

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 105

Page 116: Shkaf Knurr Electronics e

by knürr

106

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

ELECTRONIC ENCLOSURES

Interlocking SpringW H D HU/U h d kg Model Order no. UP Price

02.365.049.9 1 unit

- Printed circuit board locking without frontplate

Supply schedule1 Set of 20 units

chasseleon / Eurocard Card Guide , Push-InW H D HU/U h d kg Model / PCB thickness Order no. UP Price

160 1.3 - 2.2 02.310.010.3 1 unit220 1.3 - 2.2 02.310.011.3 1 unit280 1.3 - 2.2 02.310.012.3 1 unit

- Push-in- For card and cassette guiding on the

modular chassis

MaterialPA6.6, UL94 V-0

Supply schedule1 Guide rail

BGT20030_E

CHA00260_E

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 106

Page 117: Shkaf Knurr Electronics e

by knürr

107

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

ELECTRONIC ENCLOSURES

Cross Extrusions for chasseleon / EurocardW H D HU/U EMC Model Order no. UP Price84 431.8 A 02.310.545.9 1 unit63 352.12 A 02.310.544.9 1 unit42 218.44 A 02.310.547.9 1 unit84 431.80 B 02.310.550.9 1 unit63 352.12 B 02.310.556.9 1 unit42 218.44 B 02.310.552.9 1 unit84 431.80 C 02.310.541.9 1 unit63 352.12 C 02.310.539.9 1 unit42 218.44 C 02.310.537.9 1 unit84 431.80 C 02.317.516.6 1 unit63 352.12 C 02.317.517.6 1 unit42 218.44 C 02.317.518.6 1 unit84 431.80 D 02.350.434.9 1 unit63 352.12 D 02.350.435.9 1 unit42 218.44 D 02.350.432.9 1 unit84 431.80 E 02.350.454.9 1 unit63 352.12 E 02.350.455.9 1 unit42 218.44 E 02.350.452.9 1 unit84 431.80 F 02.310.508.9 1 unit63 352.12 F 02.310.509.9 1 unit42 218.44 F 02.310.512.9 1 unit84 431.80 F 02.317.510.9 1 unit63 352.12 F 02.317.511.9 1 unit42 218.44 F 02.317.512.9 1 unit84 431.80 AF 02.310.507.9 1 unit63 352.12 AF 02.310.518.9 1 unit42 218.44 AF 02.310.517.9 1 unit

EUR00027_E Type A1

EUR00028_E Type B2

CHA00245_E Type C3

EUR00040_E Type D4

EUR00039_E Type E5

EUR00026_E Type F6

EUR00043_E Type AF7

Type F: Cross extrusion, front- For mounting front panels- EMC version

Type AF: Cross extrusion, frontFor rear recessed cassette installationand front panels

MaterialExtruded aluminium

Supply schedule1 Cross extrusion

7

6

CHA00237_E CHA00238_E

Application examples:

Note:Other models available on request!

Please order mounting material extra

Type A: Cross extrusion, rearFor mounting backplanes

Type B: Cross extrusion, rearFor connectors in accordance withDIN 41612

Type C: Cross extrusion, frontFor subdividing the enclosure

Type D: Cross extrusion, rear, centreFor mounting backplanes

Type E: Cross extrusion, rear, centreFor connectors in accordance with DIN 41612

5

4

3

2

1

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 107

Page 118: Shkaf Knurr Electronics e

by knürr

108

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

ELECTRONIC ENCLOSURES

Z-Rail for Mounting Multipoint Connectors In accordance with DIN 41612W H D HU/U h d kg Model Order no. UP Price83 426.64 02.310.555.9 1 unit63 319.96 02.310.732.9 1 unit42 13.28 02.310.729.9 1 unit20 101.52 02.310.728.9 1 unit

EUR00041_E

MaterialExtruded aluminium

Divider Set, 6 HUW H D HU/U h d kg Model Order no. UP Price

02.361.300.9 1 unit

CHA00246_E

- For vertical subdivision of an enclosure

Mounting Kit, 3 HUFor connector DIN 41612 and backplanesW H D HU/U h d kg Model Order no. UP Price

3 backplanes 02.310.354.9 1 unit3 connector installation 02.310.350.9 1 unit

CHA00257_E

- For horizontal Double Eurocard installationin 3 HU

- The mounting kit is suitable for mountingbackplanes or connectors (DIN 41612).The side positioning in the enclosure can bemade anywhere on the 5.08 mm increment.

- Height = 3 HU (installation height = 20 HP) =5 slots

- Width 52 HP (installation width = 233.35mm)

FinishExtrusions, polishedTrims, anodised

Supply schedule1 Frame, front1 Frame, rear2 TrimsMounting material

Supply schedule 1 Plug carrier

How suppliedFlat-packed kit

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 108

Page 119: Shkaf Knurr Electronics e

by knürr

109

Dimensions in mm: W = Width, H = Height, D = Depth, h = Useful height, 1 HU = 44.45 mm, HP = 5.08 mmHU / U = Standard height unit (unit), UP = Unit of packaging, kg = Weight

ELECTRONIC ENCLOSURES

Insulating StripW H D HU/U h d kg Model Order no. UP Price

02.310.966.9 1 unit

CHA00044_E

- For mounting backplanes on the 19’’ modular chassis

- Individually set for different widths - Secure fixing with setscrew fixing

(84 HP)

MaterialPlastic, UL94 V-0

Supply schedule1 Insulating strip

Tapped StripW H D HU/U h d kg Model Order no. UP Price431.8 84 02.342.034.7 1 unit325.12 63 02.342.033.7 1 unit218.44 42 02.342.029.7 1 unit106.68 20 02.342.026.7 1 unit

CHA000271_E

- For mounting front and rear panels andbackplanes

MaterialSteel, zinc passivated, yellow chrome-plated

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 109

Page 120: Shkaf Knurr Electronics e

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 110

Page 121: Shkaf Knurr Electronics e

Strong Points and technical details Page 112Product Page 114Accessories for micado / primus Page 128

Front panels Page 138

micado 19“ Desktop Enclosure

micado

by knürr

111

ELECTRONIC ENCLOSURES

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 111

Page 122: Shkaf Knurr Electronics e

by knürr

112

ELECTRONIC ENCLOSURES

DesignThis optically appealing desktopenclosure is available with twodifferent side panels in twocolours .

Electro-magnetic compatibilityA shielding effect of 30 dB hasalready been achieved with thestandard model. With the optio-nal EMC upgrade kit, this can beincreased by over 10 dB.

Easy mounting...8 Torx screws are all it takes toput the sturdy enclosure bodytogether.

...quick and straightforwardSide flanges, top and bottomcover can be effortlessly attachedwith push-in and clip togethersystems. All screws are conse-quently concealed.

IEEE 1101.10/11As foundation for the configura-tion of CompactPCI and VME-64extensions, micado now providesa secure basis for future develop-ments.

Functional accessoriesMounting panels can be used forinstalling non-standard compo-nents.

Carrying handleWith single-handed operation and30º increment, safe and ergono-mically comfortable transport ismade possible.

7

6

5

4

3

2

1

micado 19“ Desktop EnclosureStrong points

MIC00059_E3 MIC00058_E4

MIC00057_E1 MIC00056_E2

MIC00015_E5

MIC00060_E7

MIC00025_E6

01-112_eng_final.qxd 07.08.2002 14:52 Uhr Seite 112

Page 123: Shkaf Knurr Electronics e

by knürr

113

ELECTRONIC ENCLOSURES

Material and finish- Top and bottom cover of 0.8 mm

sheet steel- Side panels of 1mm sheet steel,

zinc passivated- Side flanges and cross extru-

sions of extruded aluminium- Corner trims, of die-cast zinc

Final digit of order number .1:- Top and bottom cover RAL 7035,

light-grey- Symmetrical side flanges with

groove, RAL 7035, light-grey- Corner trims, RAL 5008, blue-

grey

Final digit of order number .4:- Top and bottom cover and cor-

ner trims,RAL 7037, dusty-grey

- Drop-shaped side flanges withrecessed grip, RAL 7035, light-grey

Desktop enclosureSheet steel construction withaluminium cross extrusions

External dimensions- Heights: 114.9; 159.3; 203.8;

297.7; 337.1 mm- Widths: 264.2; 370.9; 477.6 mm- Depths: 267.6; 327.6; 387.6;

447.6; 507.6 mm

Installation area in accordancewith IEC 297-3- Heights: 2, 3, 4, 6, 7 HU

(1 HU = 44.45 mm)- Widths: 42, 63, 84 HP

(1 HP = Horizontal pitch = 5.08mm)

TestsEMC measuring: VG 95373 part15 (30 MHz-1GHz)

How suppliedFlat-packed kit

micado 19“ Desktop EnclosureTechnical data

MIC00008

MIC00057_E

MIC00065

MIC00066

113-200_eng_final.qxd 07.08.2002 15:29 Uhr Seite 113

Page 124: Shkaf Knurr Electronics e

by knürr

114

MIC00003_E

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

micado Desktop Enclosure, 2 / 3 / 6 HUW H D HU/U w h1 h2 h3 a1 a2 a3 Order no. UP Price264.20 114.90 42 2 213.50 68.30 78.10370.90 114.90 63 2 320.20 68.30 78.10477.60 114.90 84 2 426.90 68.30 78.10

264.20 159.30 42 3 213.50 112.70 122.50370.90 159.30 63 3 320.20 112.70 122.50477.60 159.30 84 3 426.90 112.70 122.50

264.20 297.70 42 6 213.50 246.10 112.70 255.85 122.50370.90 297.70 63 6 320.20 246.10 112.70 255.85 122.50477.60 297.70 84 6 426.90 246.10 112.70 255.85 122.50

micado Desktop Enclosure, 4 / 7 HUW H D Hu/U w h1 h2 h3 a1 a2 a3 Order no. UP Price264.20 203.80 42 4 213.50 157.15 23.80 166.95 33.65370.90 203.80 63 4 320.20 157.15 23.80 166.95 33.65477.60 203.80 84 4 426.90 157.15 23.80 166.95 33.65

264.20 337.10 42 7 213.50 246.10 112.70 23.80 166.95 122.5 33.65370.90 337.10 63 7 320.20 246.10 112.70 23.80 166.95 122.5 33.65477.60 337.10 84 7 426.90 246.10 112.70 23.80 166.95 122.5 33.65

Dimensions(for all enclosure types represented)W H D d Nominal depth Order no. UP Price

267.6 235.6 240327.6 295.6 300387.6 355.6 360447.6 415.6 420407.6 475.6 480

MIC00002_E

MIC00004_E

MIC00005_E

h2h1

h2h2

h1

h3

1) = with use of functional corner trims

113-200_eng_final.qxd 07.08.2002 15:29 Uhr Seite 114

Page 125: Shkaf Knurr Electronics e

by knürr

115

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

micado With closed bottom coverW H D HU/U h w d kg PCB nom. depth Order no. UP Price42 HP 240 2U 160 02.323.212.4 1 unit42 HP 300 2U 160/220 02.323.222.4 1 unit42 HP 240 3U 160 02.323.213.x 1 unit42 HP 300 3U 160/220 02.323.223.x 1 unit

63 HP 240 2U 160 02.324.212.4 1 unit63 HP 300 2U 160/220 02.324.222.4 1 unit63 HP 240 3U 160 02.324.213.x 1 unit63 HP 300 3U 160/220 02.324.223.x 1 unit

84 HP 240 2U 160 02.326.212.4 1 unit84 HP 300 2U 160/220 02.236.222.4 1 unit84 HP 360 2U 160/220/280 02.326.232.4 1 unit84 HP 240 3U 160 02.326.213.x 1 unit84 HP 300 3U 160/220 02.326.223.x 1 unit84 HP 360 3U 160/220/280 02.326.233.x 1 unit84 HP 300 4U 160/220 02.326.224.x 1 unit84 HP 360 4U 160/220/280 02.326.234.x 1 unit84 HP 420 4U 160/220/280 02.326.244.x 1 unit84 HP 480 4U 160/220/280 02.326.254.x 1 unit84 HP 240 6U 160 02.326.216.x 1 unit84 HP 300 6U 160/220 02.326.226.x 1 unit84 HP 360 6U 160/220/280 02.326.236.x 1 unit84 HP 420 6U 160/220/280 02.326.246.x 1 unit84 HP 480 6U 160/220/280 02.326.256.x 1 unit

84 HP 300 7U 160/220 02.326.227.x 1 unit84 HP 360 7U 160/220/280 02.326.237.x 1 unit84 HP 420 7U 160/220/280 02.326.247.x 1 unit84 HP 480 7U 160/220/280 02.326.257.x 1 unit

MIC00009_E

FinishPowder-coated, textured

Colour combinationsFinal digit of order number .1: - Covers, RAL 7035 light-grey- Symmetrical side flanges with handle

groove, RAL 7035 light-grey- Corner trims, RAL 5008 blue-grey

Final digit of order number .4: - Covers and corner trims,

RAL 7037 dusty-grey- Drop-shaped side flanges with recessed

grip, RAL 7035 light-grey

NoteWith final digit of order number .1, twosymmetrical side flanges with a groove -e.g. for mounting a carrying handle - areincluded in the supply schedule

Supply schedule2 Side panels2 Side flanges1 Bottom cover, closed1 Top cover, closed4 Cross extrusions, IEC4 Corners4 Stacking feet4 Tapped stripsMounting material

How suppliedFlat-packed kit

MIC00065_E

MIC00066_E

Note:Other models available on request!

Accessories on page 128

113-200_eng_final.qxd 07.08.2002 15:29 Uhr Seite 115

Page 126: Shkaf Knurr Electronics e

by knürr

116

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

micado With corner variantsW H D HU/U h w d kg PCB nom. depth Order no. UP Price42 HP 240 3U 160 02.323.313.x 1 unit42 HP 300 3U 160/220 02.323.323.x 1 unit

63 HP 240 3U 160 02.324.313.x 1 unit63 HP 300 3U 160/220 02.324.323.x 1 unit

84 HP 240 3U 160 02.326.313.x 1 unit84 HP 300 3U 160/220 02.326.323.x 1 unit84 HP 360 3U 160/220/280 02.326.333.x 1 unit84 HP 300 4U 160/220 02.326.324.x 1 unit84 HP 360 4U 160/220/280 02.326.334.x 1 unit84 HP 420 4U 160/220/280 02.326.344.x 1 unit84 HP 480 4U 160/220/280 02.326.354.x 1 unit84 HP 240 6U 160 02.326.316.x 1 unit84 HP 300 6U 160/220 02.326.326.x 1 unit84 HP 360 6U 160/220/280 02.326.336.x 1 unit84 HP 420 6U 160/220/280 02.326.346.x 1 unit84 HP 480 6U 160/220/280 02.326.356.x 1 unit

MIC00010_E

As per choice:- Desktop enclosure with corner A or bench

enclosure with functional corner B (as aresult, vertical configuration and mountingof a front cover made possible)

FinishPowder-coated, textured

Colour combinationsFinal digit of order number .1:- Covers RAL 7035, light-grey- Symmetrical side flanges with groove

RAL 7035, light-grey- Corner trims, RAL 5008, blue-grey

Final digit of order number .4:- Covers and corner trims,

RAL 7035, dusty-grey- Drop-shaped side flanges with recessed

grip, RAL 7035, light-grey

CornerW H D HU/U h d kg Model Order no. UP Price

3 A 02.323.990.x 2 units4 A 02.323.991.x 2 units6 A 02.323.992.x 2 units

3 B, functional corner 02.323.985.x 2 units4 B, functional corner 02.323.986.x 2 units6 B, functional corner 02.323.987.x 2 units

MIC00012_E A

MIC00011_E B

- For closing the enclosure, rear and/orfront

MaterialDie-cast zinc

FinishPowder-coated, textured

Colour combinationsFinal digit of order number .1: RAL 7035,light-greyFinal digit of order number .4: RAL 5008,blue-grey

Supply schedule2 Corner trims / functional corner trims

How suppliedFlat-packed kit

Supply 2 Side panels2 Side flanges1 Bottom cover, closed1 Top cover, closed4 Cross extrusions, IEC4 Stacking feet4 Tapped stripsMounting material

How suppliedFlat-packed kit

MIC00065_E

MIC00066_E

Note:Other models available on request!

Accessories on page 128

113-200_eng_final.qxd 07.08.2002 15:29 Uhr Seite 116

Page 127: Shkaf Knurr Electronics e

by knürr

117

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

micado With perforated bottom coverW H D HU/U h w d kg PCB nom. depth Order no. UP42 HP 240 2U 160 02.323.012.4 1 unit42 HP 300 2U 160/220 02.323.022.4 1 unit42 HP 240 3U 160 02.323.013.x 1 unit42 HP 300 3U 160/220 02.323.023.x 1 unit

63 HP 240 2U 160 02.324.012.4 1 unit63 HP 300 2U 160/220 02.324.022.4 1 unit63HP 240 3U 160 02.324.013.x 1 unit63 HP 300 3U 160/220 02.234.023.x 1 unit

84 HP 240 2U 160 02.326.012.4 1 unit84 HP 300 2U 160/220 02.326.022.4 1 unit84 HP 360 2U 160/220/280 02.326.032.4 1 unit84 HP 240 3U 160 02.326.013.x 1 unit84 HP 300 3U 160/220 02.326.023.x 1 unit84 HP 360 3U 160/220/280 03.326.033.x 1 unit84 HP 300 4U 160/220 03.326.024.x 1 unit84 HP 360 4U 160/220/280 03.326.034.x 1 unit84 HP 420 4U 160/220/280 03.326.044.x 1 unit84 HP 480 4U 160/220/280 03.326.054.x 1 unit84 HP 240 6U 160 02.326.016.x 1 unit84 HP 300 6U 160/220 02.326.026.x 1 unit84 HP 360 6U 160/220/280 02.326.036.x 1 unit84 HP 420 6U 160/220/280 02.326.046.x 1 unit84 HP 480 6U 160/220/280 02.326.056.x 1 unit84 HP 300 7U 160/220 02.326.027.x 1 unit84 HP 360 7U 160/220/280 02.326.037.x 1 unit84 HP 420 7U 160/220/280 02.326.047.x 1 unit84 HP 480 7U 160/220/280 02.326.057.x 1 unit

MIC00013_E

MIC00051_E

FinishPowder-coated, textured

Colour combinationsFinal digit of order number .1: - Covers, RAL 7035 light-grey- Symmetrical side flanges with handle

groove, RAL 7035 light-grey- Corner trims, RAL 5008 blue-grey

Final digit of order number .4: - Covers and corner trims,

RAL 7037 dusty-grey- Drop-shaped side flanges with recessed

grip, RAL 7035 light-grey

Supply schedule2 Side panels2 Side flanges1 Bottom cover, perforated1 Top cover, closed4 Cross extrusions, IEC4 Corners4 Stacking feet4 Tapped stripsMounting material

How suppliedFlat-packed kit

MIC00065_E

MIC00066_E

Note:Other models available on request!

Accessories on page 128

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 117

Page 128: Shkaf Knurr Electronics e

by knürr

118

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

micado with IEEE 1101.10 Front ExtrusionFor CompactPCI and VME64x ApplicationsW H D HU/U Pr. circ. board nom. depth Order no. UP42 HP 240 3U 160 02.323.513.x 1 unit42 HP 300 3U 160/220 02.323.523.x 1 unit42 HP 240 4U 160 02.323.514.x 1 unit42 HP 300 4U 160/220 02.323.524.x 1 unit

63 HP 240 3U 160 02.324.513.x 1 unit63 HP 300 3U 160/220 02.324.523.x 1 unit

84 HP 240 3U 160 02.326.513.x 1 unit84 HP 300 3U 160/220 02.326.523.x 1 unit84 HP 360 3U 160/220/280 02.326.533.x 1 unit84 HP 300 4U 160/220 02.326.524.x 1 unit84 HP 360 4U 160/220/280 02.326.534.x 1 unit84 HP 420 4U 160/220/280 02.326.544.x 1 unit84 HP 480 4U 160/220/280 02.326.554.x 1 unit84 HP 240 6U 160 02.326.516.x 1 unit84 HP 300 6U 160/220 02.326.526.x 1 unit84 HP 360 6U 160/220/280 02.326.536.x 1 unit84 HP 420 6U 160/220/280 02.326.546.x 1 unit84 HP 480 6U 160/220/280 02.326.556.x 1 unit84 HP 300 7U 160/220 02.326.527.x 1 unit84 HP 360 7U 160/220/280 02.326-537.x 1 unit84 HP 420 7U 160/220/280 02.326.547.x 1 unit84 HP 480 7U 160/220/280 02.326.557.x 1 unit

MIC00014_E

MIC00015_E FinishPowder-coated, textured

Colour combinationsFinal digit of order number .1: - Covers, RAL 7035 light-grey- Symmetrical side flanges with handle

groove, RAL 7035 light-grey- Corner, RAL 5008 blue-grey

Final digit of order number .4: - Covers and corner trims,

RAL 7037 dusty-grey- Drop-shaped side flanges with recessed

grip, RAL 7035 light-grey

Supply schedule2 Side panels2 Side flanges1 Bottom cover, perforated1 Top cover, closed4 Cross extrusions, IEEE4 Corners4 Stacking feet4 Tapped stripsMounting material

How suppliedFlat-packed kit

MIC00065_E

MIC00066_E

Note:Other models available on request!

Accessories on page 128

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 118

Page 129: Shkaf Knurr Electronics e

by knürr

119

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging Note:

Other models available on request!

Accessories on page 128

Front CoverW H D HU/U h d kg Model Order no. UP Price42 HP 3U 02.323.912.1 1 unit42 HP 4U 02.323.915.1 1 unit42 HP 6U 02.323.918.1 1 unit

63 HP 3U 02.323.913.1 1 unit63 HP 4U 02.323.916.1 1 unit63 HP 5U 02.323.919.1 1 unit

84 HP 3U 02.323.914.1 1 unit84 HP 4U 02.323.917.1 1 unit84 HP 6U 02.323.920.1 1 unit

MIC00019_E

MIC00060_E

- Protects the installations- Provides direct access to the installations - Can be optionally opened up or down

Material / Finish- Metal frame, powder-coated, textured

RAL 7035, light-grey- Plexiglass panel, 3 mm, transparent

Supply schedule1 Transparent front coverMounting material

How suppliedPre-assembled

Carrying HandleW H D HU/U h d kg Model Order no. UP Price42 HP 02.323.900.1 1 unit63 HP 02.323.901.1 1 unit84 HP 02.323.902.1 1 unit

MIC00016_E

- For 3, 4, 6 HU enclosure with symmetricalside flanges

- Comfortable carrying provided by foam pad-ded carrying handle

- Single-handed use- Interlocking on the 30° increment- Load rating up to 25 kg

MaterialHandle: sheet steel 25 x 12.5 x 1.5 mmHandle covering: TPECover: PA

FinishHandle, powder-coated, textured,RAL 7035 light-greyFoam padding and cover, RAL 5008

Note:Mounting the handle is only possible onenclosures with 3, 4, 6 HU and symmetr-cal side flanges with carry groove.

Supply schedule1 Carrying handle2 Sliding blocksMounting material

How suppliedPre-assembled

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 119

Page 130: Shkaf Knurr Electronics e

by knürr

120

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Screw-On and Tilt FeetW H D HU/U h d kg Model Order no. UP Price

02.323.906.x 1 unit

- For improved ventilation through the bottomcover

MaterialDie-cast zinc

FinishPowder-coated, textured

Colour combinationsFinal digit of order number .1: RAL 7035,light-greyFinal digit of order number .4: RAL 7037dusty-grey

Supply schedule2 Screw-on feet2 Tilt feet

How suppliedFlat-packed kit

MIC00023_E

Mounting Unit For non-standard installationsW H D HU/U h d kg Model Order no. UP Price21 HP 360 3U 02.324.918.1 1 unit21 HP 420 3U 02.324.919.1 1 unit21 HP 480 3U 02.324.920.1 1 unit21 HP 420 4U 02.324.922.1 1 unit21 HP 480 4U 02.324.923.1 1 unit21 HP 420 6U 02.324.925.1 1 unit21 HP 480 6U 02.324.926.1 1 unit

42 HP 360 3U 02.324.933.1 1 unit42 HP 420 3U 02.324.934.1 1 unit42 HP 480 3U 02.324.935.1 1 unit42 HP 420 4U 02.324.937.1 1 unit42 HP 480 4U 02.324.938.1 1 unit42 HP 420 6U 02.324.940.1 1 unit42 HP 480 6U 02.324.941.1 1 unit

- Mounting option for non-19’’ components onthe mounting panel

- Easy access to the installations- Mixed design (19’’ and non-standard

installations) also an option- Easy servicing due to removable

components

MaterialSheet steel, zinc passivatedSupply schedule1 Mounting panel2 Inclined brackets1 Front panel1 Front panel handleMounting material

How suppliedFlat-packed kit

MIC00025_E

Note:Other models available on request!

Accessories on page 128

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 120

Page 131: Shkaf Knurr Electronics e

by knürr

121

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging Note:

Other models available on request!

Accessories on page 128

Earthing SetW H D HU/U h d kg Model Order no. UP Price

02.323.971.9 1 unit

- For safe protective earth connection inaccordance with IEC 950

- Contact resistance < 0.1 Ohm/25 A

Supply schedule2 Earth connectionsMounting material

How suppliedFlat-packed kitMIC00029_E

Air-Inhibiting PlateW H D HU/U h d kg Model Order no. UP Price42 HP 2, 3, 6 02.323.908.9 1 unit63 HP 2, 3, 6 02.323.909.9 1 unit84 HP 2, 3, 6 02.323.910.9 1 unit

42 HP 4, 7 02.323.975.9 1 unit63 HP 4, 7 02.323.976.9 1 unit84 HP 4, 7 02.323.977.9 1 unit

MIC00027_E

- Provides the targetted ventilation airflow inthe enclosure

Material / FinishSheet steel, zinc passivated

Supply schedule1 Air-inhibiting plate1 Edge protector

How suppliedFlat-packed kit

Filter MatW H D HU/U h d kg For enclosure depth Order no. UP Price42 HP 240/300 02.323.958.9 1 unit63 HP 240/300 02.323.961.9 1 unit84 HP 240/300 02.323.964.9 1 unit

42 HP 360 02.323.959.9 1 unit63 HP 360 02.323.962.9 1 unit84 HP 360 02.323.965.9 1 unit

42 HP 480 02.323.960.9 1 unit63 HP 480 02.323.963.9 1 unit84 HP 480 02.323.966.9 1 unitMIC00026_E

- Protects installations from dust

MaterialPlastic fibrous web

Supply schedule1 Loop and hook tape, self-locking1 Fan mat

How suppliedFlat-packed kit

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 121

Page 132: Shkaf Knurr Electronics e

by knürr

122

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

EMC KitW H D HU/U h d kg Model Order no. UP Price42 HP 240 02.324.961.9 1 unit63 HP 240 02.324.962.9 1 unit84 HP 240 02.324.963.9 1 unit

42 HP 300 02.324.964.9 1 unit63 HP 300 02.324.965.9 1 unit84 HP 300 02.324.966.9 1 unit

42 HP 360 02.324.967.9 1 unit63 HP 360 02.324.968.9 1 unit84 HP 360 02.324.969.9 1 unit

42 HP 420 02.324.970.9 1 unit63 HP 420 02.324.971.9 1 unit84 HP 420 02.324.972.9 1 unit

42 HP 480 02.324.973.9 1 unit63 HP 480 02.324.974.9 1 unit84 HP 480 02.324.975.9 1 unit

- For increasing enclosure shielding effect

Supply schedule4 EMC Stainless steel springs for cross

extrusions4 Seals for side panels

How suppliedFlat-packed kit

MIC00055_E

Note:Other models available on request!

Accessories on page128

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 122

Page 133: Shkaf Knurr Electronics e

Strong Points and technical details Page 124Product 19“ modular chassis Page 126Accessories for primus / micado Page 128

Front panels Page 138

primus 19“ Modular Chassis

primus

by knürr

123

ELECTRONIC ENCLOSURES

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 123

Page 134: Shkaf Knurr Electronics e

by knürr

124

ELECTRONIC ENCLOSURES

All your requirements are cover-ed using just one system! Themodular chassis concept - EMCprotection and shock-vibrationresistance in the basic system -reduces assembly and logisticcosts.

The mounting of the modularchassis’ is easy, quick and there-fore cost-effective. The connec-tion system eliminates the needfor assembly gauges.

Easy access to the internalinstallation saves assembly time.

3

2

1

A high shielding effect againstelecro-magnetic disturbances iscost-effectively attained. This isreached by using an innovativeconnection system, by minimisingthe number of components, andby using materials with highlyconductive surfaces.The shielding effect is increasedthrough the direct contact bet-ween backplane and rear crossstrips.

A safe cooling of the modules andsimultaneous EMC protection isguaranteed by the defined posi-tioning of the perforations in thecovers.

With the reinforced 19“ adapterand form-fit interconnections,even with the basic system, avibration-proof modular chassisis the result.

The modular chassis design isconsequently further developedin the tailormade range of acces-sories. The pull-out handle of thepush-pull tool increases the levereffect and therefore makes iteven easier to push and pull themodule with high-pole connec-tors. The self-locking constructionguarantees safe mounting of thefront panel without using screws.

With the lever handles in accor-dance with IEEE 1101.10, pushand pull loads of up to 500 N canbe easily handled.

8

7

6

5

4

primus 19“ Modular ChassisStrong points

BGT00017_E1

BGT00022_E5

BGT00018_E2

BGT00019_E3

BGT00023_E6

BGT00286_E8

BGT00020_E4

BGT00024_E7

BGT00016_E1

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 124

Page 135: Shkaf Knurr Electronics e

BGT00125_E

by knürr

125

ELECTRONIC ENCLOSURES

In accordance with IEC 297-3/4Sheet steel construction with aluminium cross extrusions

External dimensions in accor-dance with IEC 297-3- Width 448 mm,

- via 19“ adapter482.6 mm

- Heights 3 HU (132.5 mm)6 HU (265.8 mm)

- Depths 220, 280, 340 and 400mm

Installation area- Width 84 HP- Heights 3 and 6 HU- Nominal depths 160, 220,

280 mm and additional moun-ting level at 340 mm

Installation in 19“ racksand enclosures- With adapter- With chassis rails

Material and finish- Side panels, covers, cross strips

and rear panel: sheet steel 1.0mm, zinc passivated

- Cross extrusions front:extruded aluminium,

- 19“ Adapter, powder-coated,light-grey, smooth, RAL 7035

- Handles: die-cast aluminium /aluminium extrusion, powder-coated, grey-blue, RAL 5008

Tests-EMC MeasuringVG 95 373 part 15 (30 MHz-1GHz)

- Shock and vibration resistancemeasuring in accordance withtest specifications MIL-STD 810E,DIN 43 331, BN 411002,NF F 60-002

How suppliedFlat-packed kit

primus 19“ Modular ChassisTechnical data

primus 19“ Modular Chassis 3 / 6 / 9 HUHU C C A B H h1 h2 h3 a1 a2 a3 b1 b23 (1x3) 84 426.72 482.6 465.1 132.5 112.7 - - 122.5 - - 57.15 -6 (2x3) 84 426.72 482.6 465.1 265.8 - 112.7 - - 122.5 - 190.5 -6 (1x6) 84 426.72 482.6 465.1 265.8 246.1 - - 255.8 - - 190.5 -9 (1x3 + 1x6) 84 426.72 482.6 465.1 399.2 - 246.1 112.7 - 255.8 122.5 120.6 101.69 (3x3) 84 426.72 482.6 465.1 399.2 - - 112.7 - - 122.5 120.6 101.69 (1x9) 84 426.72 482.6 465.1 399.2 379.5 - - 389.2 - - 120.6 101.6

BGT00130_E

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

1) = additional mounting level

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 125

Page 136: Shkaf Knurr Electronics e

by knürr

126

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

19“ Modular ChassisW H D HU/U h1 a1 kg Model / Nominal depth Order no. UP Price84 HP 223 3 112.7 122.5 2.1 160 02.340.003.1 1 unit84 HP 283 3 112.7 122.5 2.8 160/220 02.340.033.1 1 unit84 HP 343 3 112.7 122.5 3.5 60/220/280 02.340.073.1 1 unit84 HP 403 3 112.7 122.5 4.1 160/220/280 02.340.123.1 1 unit84 HP 223 6 246.1 255.8 2.8 160 02.340.006.1 1 unit84 HP 283 6 246.1 255.8 3.5 160/220 02.340.036.1 1 unit84 HP 343 6 246.1 255.8 4.5 160/220/280 02.340.076.1 1 unit84 HP 403 6 246.1 255.8 5.2 160/220/280 02.340.126.1 1 unit84 HP 283 9 379.5 389.2 4.3 160/220 02.340.039.1 1 unit84 HP 343 9 379.5 389.2 5.1 160/220/280 02.340.079.1 1 unit84 HP 403 9 379.5 389.2 5.8 160/220/280 02.340.129.1 1 unit

FinishSheet steel panels,zinc passivated19’’ Adapter,powder-coated, RAL 7035 (light-grey)

How suppliedFlat-packed kit

Supply schedule2 Side panels2 19’’ Adapters2 Cross strips, rearCross strip, rear, centre, thin(1 x at 6 HU, 2 x at 9HU)1 Top cover with cross extrusion, front1 Bottom cover with cross extrusion, front2 Tapped strips4 Label stripsMounting material

BGT00096_E

19“ Modular Chassis in accordance with IEEE1101.10W H D HU/U h1 a1 kg Model / Nominal depth Order no. UP Price84 HP 230 3 112.7 122.5 2.1 160 02.340.012.1 1 unit84 HP 290 3 112.7 122.5 2.8 160/220 02.340.013.1 1 unit84 HP 350 3 112.7 122.5 3.5 160/220/280 02.340.014.1 1 unit84 HP 410 3 112.7 122.5 4.1 160/220/280 02.340.015.1 1 unit84 HP 230 6 246.1 255.8 2.8 160 02.340.022.1 1 unit84 HP 290 6 246.1 255.8 3.5 160/220 02.340.023.1 1 unit84 HP 350 6 246.1 255.8 4.5 160/220/280 02.340.024.1 1 unit84 HP 410 6 246.1 255.8 5.2 160/220/280 02.340.025.1 1 unit

FinishSheet steel panels,zinc passivated19’’ Adapter,powder-coated, RAL 7035 (light-grey)

How suppliedFlat-packed kit

Supply schedule2 Side panels2 19’’ Adapters2 Cross strips, rearCross strip, rear, centre, thin(at 6 HU)1 Top cover with cross extrusion, IEEEfront1 Bottom cover with cross extrusion, IEEEfront2 Tapped strips4 Label stripsMounting material

BGT00097_E

BGT00301_E

BGT00097_E

19“ Modular Chassis in acc. with IEEE1101.11 (REAR I/0)W H D HU/U h1 a1 kg Model / Nominal depth Order no. UP Price84 HP 300 3 112.7 122.5 3.8 160/80 02.340.133.1 1 unit84 HP 300 6 246.1 255.8 4.4 160/80 02.340.136.1 1 unit

FinishSheet steel panels,zinc passivated19’’ Adapter,powder-coated, RAL 7035 (light-grey)

How suppliedFlat-packed kit

Supply schedule2 Side panels2 19’’ Adapters2 Cross strips, rear1 Top cover with cross extrusion, front1 Bottom cover with cross extrusion, front2 Tapped strips4 Label stripsMounting material

Note:Please order handles and other accessoriesextra! Other models available on request!

Accessories on page 128

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 126

Page 137: Shkaf Knurr Electronics e

by knürr

127

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Bottom-Hinged PanelW H D HU/U h d kg Model Order no. UP Price

3 Standard 02.340.213.9 1 unit3 EMC version 02.340.223.9 1 unit6 Standard 02.340.216.9 1 unit6 EMC version 02.340.226.9 1 unit

- Removable without tools- Only 1 part for 2 variants- Straightforward for EMC application, just

clip the stainless steel springs onto the rearpanel

- Additional screw fastening necessary forshock and vibration-proof requirements

MaterialSheet steel 1 mm, zinc passivated

Supply schedule1 Bottom-hinged rear panel2 EMC version additional fasteners4 Stainless steel springs4 Spacers

BGT00208_E

Change AdapterW H D HU/U h d kg Model Order no. UP Price

3 02.340.293.1 1 unit6 02.340.296.1 1 unit

- For mounting in metric (20 Module) or 19”cabinets and enclosures

Material / FinishCorner extrusion: extruded aluminiumChange adapter: sheet steel, powder-coated, RAL 7035 light-grey

Supply schedule2 Corner extrusions2 19’’/20 Module change adapter

BGT00305_E

Note:Other models available on request!

Accessories on page 128

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 127

Page 138: Shkaf Knurr Electronics e

by knürr

128

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Label StripsW H D HU/U h d kg Model Order no. UP Price

02.300.146.9 4 units

- With figures from 01 to 84- For attaching to the cross extrusion, front

MaterialAluminium film, printed, self-adhesive

Supply schedule4 Label strips

Backplane Insulation FilmW H D HU/U h d kg Model Order no. UP Price

top/bottom 02.340.200.0 10 unitcentre 02.340.201.0 10 unit

- Simple attachment to the backplaneand cross strip

MaterialSelf-adhesive insulation film, 0.2 mm(polycarbonate)

Supply schedule10 Insulation films

BGT00209_E

BGT00210_E

Tapped StripW H D HU/U h d kg Model Order no. UP Price431.8 84 02.342.034.7 1 unit325.12 63 02.342.033.7 1 unit218.44 42 02.342.029.7 1 unit106.68 20 02.342.026.7 1 unit

- For screws, M 2.5

MaterialSteel, zinc passivated,yellow chrome-plated

Supply schedule1 Tapped strip

BGT00058_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 128

Page 139: Shkaf Knurr Electronics e

by knürr

129

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Card Guide, IEC297-3W H D HU/U h d kg Model / PCB thickness Order no. UP Price

160 1.3 - 2.2 02.342.090.1 1 unit220 1.3 - 2.2 02.342.091.1 1 unit180 1.3 - 2.2 02.342.092.1 1 unit

- For installing PCBs and cassettes in themodular chassis

- Shock and vibration-proof only with clip-ontechnology

MaterialPlastic UL94-V0

Supply schedule1 Card guide

ESD Spring, IEC 297-3W H D HU/U h d kg Model Order no. UP Price

02.340.202.2 1 set

- Discharges electro-static charges in accor-dance with conductive printed circuit boards

- Cassette installation possible

MaterialStainless steel

Supply schedule1 Set of 10 units

BGT20022_E

BGT20023_E

Card Guide, IEEE1101.10W H D HU/U h d Model / PCB thickness Order no. UP Price

80 max. 2.4 02.342.108.1 1 unit160 1.3-2.2 02.342.093.1 1 unit220 1.3-2.2 02.342.094.1 1 unit280 1.3-2.2 02.342.095.1 1 unit

- For installing PCBs and cassettes in themodular chassis

- Shock and vibration-proof only with clip-ontecnology

MaterialPlastic UL94-V0

Supply schedule1 Card guide

NoteCassette installation is not possible withcard guides that comply with IEEE 1101.10

BGT20032_E

BGT20025_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 129

Page 140: Shkaf Knurr Electronics e

by knürr

130

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

- 3-Piece with aluminium centre extrusion forincreased requirements

- Shock and vibration-proof only with clip-ontechnology system

MaterialPlastic UL94-V0

Supply schedule1 Card guide

Card Guides, IEEE1101.103-Piece with aluminium centre extrusion for increased requirementsd Model / PCB thickness Order no. UP Price

80 corner, single / 2.4 02.342.096.1 1 unit160 complete / 2.4 02.340.634.1 1 unit220 complete / 2.4 02.340.635.1 1 unit280 complete / 2.4 02.340.636.1 1 unit

80 corner, single, card level offset by 2.54 mm / 2.4 02.342.080.1 1 unit160 complete / 2.4 02.342.081.1 1 unit220 complete / 2.4 02.342.082.1 1 unit280 complete / 2.4 02.342.083.1 1 unit

BGT20031_E

BGT20033_E

Coding Accessories for Card Guide, IEEE1101.10W H D HU/U h d Model Order no. UP Price

right 02.340.190.1 50 unitsleft 02.340.191.1 50 units

- Coding adapter- Increases coding options

MaterialPlastic UL94-V0

Supply schedule1 Set of 50 units

BGT20027_E

Coding Accessories for Card Guide, IEEE1101.10W H D HU/U h d Model Order no. UP Price

02.340.189.1 100 units

- Coding pin- Increases coding options

MaterialPlastic

Supply schedule1 Set of 100 units

BGT20020_E

ESD Spring for Card Guide , IEEE1101.10W H d HU/U h d Model Order no. UP Price

02.340.194.0 10 units

- Discharges electro-static charges in accor-dance with conductive printed circuit boards

MaterialStainless steel

Supply schedule1 Set of 10 units

BGT20028_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 130

Page 141: Shkaf Knurr Electronics e

by knürr

131

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Front SetW H D HU/U h d Model Order no. UP Price431.8 84 02.340.187.9 1 unit325.12 63 02.340.186.9 1 unit218.44 42 02.340.182.9 1 unit106.68 20 02.340.179.9 1 unit

- Safe bonding and positioning of the frontpanel with the cross extrusion - even withpainted or anodized surface = Guide strip = Contact spring

MaterialStainless steel

Supply schedule10 Contact springs10 Guide strips

EMC Spring and Contact StripW H D HU/U h d Model Order no. UP Price

1 02.340.203.0 1 unit3 02.340.204.0 1 unit

- For bonding EMC front panels with sidepanel

- Easy push-fit mounting- Retrofittable

MaterialStainless steel

NoteMicado:2 Sets required per vertical step (frontand rear)

Primus:1 Set required per vertical step (front only)

Supply schedule1 Stainless steel spring1 Contact strip

BGT00132_E

MIC00036_E

BGT00214_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 131

Page 142: Shkaf Knurr Electronics e

by knürr

132

BGT00050_E

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Mounting KitW H D HU/U h d Model Order no. UP Price

160 3 EMC version 02.340.430.1 1 unit220 3 EMC version 02.340.431.1 1 unit280 3 EMC version 02.340.432.1 1 unit

- For horizontal installation of DoubleEurocard in a 3 HU enclosure

- Direct fan mounting possible on the sidepanel (mounting spacing, 71.5 mm)

- Height, 3 HU- Width, 55 HP- Installation width, 6 HU = 233.35 mm

Material / FinishSide panels, top and bottom cover andcross strip of sheet steel, 1 mm, zinc pas-sivatedCross extrusion of extruded aluminiumCovers of aluminium,powder-coated, light-grey, smooth,

RAL 7035Supply schedule2 Side panels with cross extrusion, front1 Top cover1 Bottom civer1 Cross strip (narrow), rear centre2 Covers1 EMC Adaption front panel, 2.5 HP

includes EMC spring2 Tapped stripsMounting material

How suppliedPre-assembled

Horizontal SubdivisionW H D HU/U h d Model Order no. UP Price

160 6 primus 02.340.016.0 1 unit220 6 primus 02.340.017.0 1 unit280 6 primus 02.340.018.0 1 unit

160 6 micado 02.323.980.0 1 unit220 6 micado 02.323.981.0 1 unit

- For horizontal subdivision- micado / primus structure with

horizontal subdivider- A = Useful installation area for 2 x 3 HU- B = Useful installation area for 1 x 6 HU- A + B + 2 HP = 84 HP- Horizontal subdivider 1 x 6 HU / 2 x 3 HU- 1 Divider- 2 Front panel sections, 2 HP or

EMC front panel section- 3 Cross extrusions, front, centre- 4 Divider strip- 5 Cross strips (narrow) rear, centre- 6 Screws

MaterialSheet steel, 1 mm, zinc passivated

Supply schedule1 Divider

Front Panel Section, 2 HPW H D HU/U h d Model Order no. UP Price

EMC version 02.340.021.1 1 unit

- For covering the divider

MaterialAluminium, 2.5 mmWith EMC version: extruded aluminium,powder-coated, light-grey smooth, RAL 7035, points of contact, polished

Supply schedule1 Front panel section1 Spring (EMC version)Mounting material

BGT00206_E

MIC00069_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 132

Page 143: Shkaf Knurr Electronics e

by knürr

133

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Cross Extrusion, Front, CentreFor horizontal subdivision of the enclosureW H D HU/U h d Model Order no. UP Price431.8 84 IEC, primus 02.340.058.7 1 unit431.8 84 IEEE, primus 02.340.059.7 1 unit325.12 63 IEC, primus 02.340.057.7 1 unit218.44 42 IEC, primus 02.340.053.7 1 unit106.68 20 IEC, primus 02.340.050.7 1 unit

431.8 84 IEC, micado 02.324.985.0 1 unit431.8 84 IEEE, micado 02.324.994.0 1 unit325.12 63 IEC, micado 02.324.984.0 1 unit325.12 63 IEEE, micado 02.324.993.0 1 unit218.44 42 IEC, micado 02.324.940.0 1 unit218.44 42 IEEE, micado 02.324.989.0 1 unit106.68 20 IEC, micado 02.324.977.0 1 unit106.68 20 IEEE, micado 02.324.986.0 1 unit

MaterialExtruded aluminium

Supply schedule1 Cross extrusionMounting material

Subdivider StripW H D HU/U h d Model Order no. UP Price325.12 63 02.340.147.0 1 unit218.44 42 02.340.143.0 1 unit106.68 20 02.340.140.0 1 unit

- For partial subdivision in 2 x 3 HU in conjunction with divider and front panel section, 2 HP

MaterialSheet steel, 1 mm, zinc passivated

Supply scheduleMounting material

Cross Strip (narrow), Rear, CentreW H D HU/U h d Model Order no. UP Price431.8 84 02.340.168.0 1 unit

- For fixing backplanes or plug carriers - Installation parts are mounted with self-

tapping screws directly with the cross strip

MaterialSheet steel, 1 mm, zinc passivated

Supply schedule (narrow)1 Cross strip, rear centre Mounting material

MIC00068_E

BGT00135_E

BGT00136_E

Note: Other models availbale onrequest!

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 133

Page 144: Shkaf Knurr Electronics e

by knürr

134

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Cross Strip, Rear, CentreW H D HU/U h d Model Order no. UP Price431.8 84 02.340.158.0 1 unit325.12 63 02.340.157.0 1 unit218.44 42 02.340.153.0 1 unit106.68 20 02.340.150.0 1 unit

- For fixing card guides and mounting back-planes or plug carriers

- Installation parts mounted using self-tapping screws directly with the cross strip

MaterialSheet steel, 1 mm, zinc passivated

Supply schedule1 Cross strip, rear, centreMounting material

Cross Strip (top / bottom)W H D HU/U h d Model Order no. UP Price431.5 84 02.340.170.0 1 unit325.15 63 02.340.167.0 1 unit218.44 42 02.340.163.0 1 unit

- For mounting an additional mounting level

MaterialSheet steel, 1 mm, zinc passivated

Supply schedule2 Cross stripsMounting material

Plug CarrierW H D HU/U h d Model Order no. UP Price430 84 02.342.451.0 1 unit323.3 63 02.342.450.0 1 unit216.6 42 02.342.446.0 1 unit104.8 20 02.342.443.0 1 unit

- For connectors in accordance with DIN41612

- Mounting spacing, 90 mm- Connectors mounted using self-tapping scr-

ews

MaterialSheet steel, 1 mm, zinc passivated

Supply schedule1 Plug carrier

BGT00134_E

BGT00202_E

BGT00203_E

Note: Other models availbale onrequest!

t

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 134

Page 145: Shkaf Knurr Electronics e

by knürr

135

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Torx Screws M4W H D HU/U h d Model Order no. UP Price

35 M 4 02.340.026.1 50 units

6 M 2.5 02.340.027.9 50 units12 M 2.5 02.340.028.9 50 units

- Self-tapping- M 4 for mounting cross extrusions and cross

strips- M 2.5 for mounting connectors and backpla-

nes on the cross strip

Supply schedule1 Set of 50 units

Bit - TX 20W H D HU/U h d Model Order no. UP Price

02.340.030.9 2 units

- For bit screwdriver

Supply schedule2 Bits

Screw Driver TX 8W H D HU/U h d Model Order no. UP Price

02.340.029.9 1 unit

- For Torx screws M 2.5Screwdriver blade length, 230 mm

Supply schedule1 Screwdriver

BGT00124_E

BGT00228_E

Ø 8

Ø 4

2.5

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 135

Page 146: Shkaf Knurr Electronics e

by knürr

136

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Rear Panel with Cable Mounting, 84 HPW H D HU/U h d Model Order no. UP Price

3 02.323.941.1 1 unit4 02.323.942.1 1 unit6 02.323.943.1 1 unit

- For orderly mounting of power cables

Material / FinishAluminium panel, powder-coated,smooth, RAL 7035, light-grey

How suppliedFlat-packed kit

Supply schedule1 Rear panel2 Cable windersMounting material

MIC00022_E

Front / Rear PanelW H D HU/U h d Model Order no. UP Price42 HP 2 Standard 02.323.932.1 1 unit63 HP 2 Standard 02.324.933.1 1 unit84 HP 2 Standard 02.323.994.1 1 unit

42 HP 3 Standard 02.340.553.1 1 unit63 HP 3 Standard 02.340.554.1 1 unit84 HP 3 Standard 02.340.555.1 1 unit

84 HP 4 Standard 02.323.937.1 1 unit

84 HP 6 Standard 02.340.595.1 1 unit

84 HP 7 Standard 02.323.940.1 1 unit

42 HP 2 EMC 02.324.945.1 1 unit63 HP 2 EMC 02.324.946.1 1 unit84 HP 2 EMC 02.324.947.1 1 unit

42 HP 3 EMC 02.340.099.1 1 unit63 HP 3 EMC 02.340.100.1 1 unit84 HP 3 EMC 02.340.101.1 1 unit

84 HP 4 EMC 02.324.950.1 1 unit

84 HP 6 EMC 02.340.117.1 1 unit

84 HP 7 EMC 02.324.953.1 1 unit

MaterialAluminium panel, 2.5 mmEMC: aluminium plate, 2-piece,with recessed U-shaped brackets

FinishPowder-coated, smooth,RAL 7035 light-greyContact points, polished (EMC version)

Supply schedule1 Front / Rear panel1 EMC Spring (only with EMC version)Mounting material

How suppliedFlat-packed kit

MIC00021_E

Note: Other models availbale onrequest!

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 136

Page 147: Shkaf Knurr Electronics e

by knürr

137

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Front / Rear Panel, PerforatedW H D HU/U h d Model Order no. UP Price42 HP 2 Standard 02.324.900.1 1 unit63 HP 2 Standard 02.324.901.1 1 unit84 HP 2 Standard 02.324.902.1 1 unit42 HP 3 Standard 02.324.903.1 1 unit63 HP 3 Standard 02.324.904.1 1 unit84 HP 3 Standard 02.324.905.1 1 unit84 HP 4 Standard 02.324.908.1 1 unit84 HP 6 Standard 02.324.911.1 1 unit84 HP 7 Standard 02.324.914.1 1 unit

42 HP 3 EMC 02.323.944.1 1 unit63 HP 3 EMC 02.324.945.1 1 unit84 HP 3 EMC 02.323.946.1 1 unit84 HP 4 EMC 02.323.949.1 1 unit84 HP 6 EMC 02.323.952.1 1 unit

- For better ventilation of the enclosed com-ponents

MaterialAluminium panel, 2.5 mmEMC: aluminium plate, 2-piece,with recessed U-shaped brackets

FinishPowder-coated, smooth, RAL 7035 light-grey

Contact points, polished (EMC version)Supply schedule1 Front / Rear panel perforated1 EMC Spring (only with EMC version)Mounting material

How suppliedFlat-packed kit

MIC00020_E

Hinged Front Panel, 3 and 6 HUW H D HU/U h d Model Order no. UP Price21 3 EMC 02.340.260.1 1 unit42 3 EMC 02.340.261.1 1 unit63 3 EMC 02.340.262.1 1 unit84 3 EMC 02.340.263.1 1 unit

21 6 EMC 02.340.264.1 1 unit42 6 EMC 02.340.265.1 1 unit63 6 EMC 02.340.266.1 1 unit84 6 EMC 02.340.267.1 1 unit

- Removable with modular chassis’ at 180°

MaterialFront panel sectionStandard: aluminium, 2.5 mmEMC: aluminium plate, two-piece with stainless steel spring

FinishPowder-coated, smooth, RAL 7035 light-grey

Supply schedule1 Hinged front panel1 EMC SpringMounting material

Push-Pull Tool for PCBsW H D HU/U h d Model Order no. UP Price

02.340.335.9 10 units

- For modules without front panel section- Only 1 piece- With moulded cotter pin, can be mounted

without screws

FinishGrey-blue RAL 5008

Supply schedule10 Push-pull tools10 ESD springs

MIC00037_E

MIC00040_E

BGT00068_E

Note: Other models available onrequest!

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 137

Page 148: Shkaf Knurr Electronics e

by knürr

138

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Front Panel Section, 3 HU and 6 HUW H D HU/U h d Model Order no. UP Price

4 HP 3 painted 02.340.541.1 1 unit4 HP 3 anodised 02.340.541.6 1 unit4 HP 6 painted 02.340.581.1 1 unit4 HP 6 anodised 02.340.581.6 1 unit6 HP 3 painted 02.340.543.1 1 unit6 HP 3 anodised 02.340.543.6 1 unit6 HP 6 painted 02.340.583.1 1 unit6 HP 6 anodised 02.340.583.6 1 unit8 HP 3 painted 02.340.545.1 1 unit8 HP 3 anodised 02.340.545.6 1 unit8 HP 6 painted 02.340.585.1 1 unit8 HP 6 anodised 02.340.585.6 1 unit

10 HP 3 painted 02.340.547.1 1 unit10 HP 3 anodised 02.340.547.6 1 unit10 HP 6 painted 02.340.587.1 1 unit10 HP 6 anodised 02.340.587.6 1 unit12 HP 3 painted 02.340.548.1 1 unit12 HP 3 anodised 02.340.548.6 1 unit12 HP 6 painted 02.340.588.1 1 unit12 HP 6 anodised 02.340.588.6 1 unit21 HP 3 painted 02.340.551.1 1 unit21 HP 3 anodised 02.340.551.6 1 unit21 HP 6 painted 02.340.591.1 1 unit21 HP 6 anodised 02.340.591.6 1 unit42 HP 3 painted 02.340.553.1 1 unit42 HP 3 anodised 02.340.553.6 1 unit42 HP 6 painted 02.340.593.1 1 unit42 HP 6 anodised 02.340.593.6 1 unit63 HP 3 painted 02.340.554.1 1 unit63 HP 3 anodised 02.340.554.6 1 unit63 HP 6 painted 02.340.594.1 1 unit63 HP 6 anodised 02.340.594.6 1 unit84 HP 3 painted 02.340.555.1 1 unit84 HP 3 anodised 02.340.555.6 1 unit84 HP 6 painted 02.340.595.1 1 unit84 HP 6 anodised 02.340.595.6 1 unit

MaterialAluminium panel, 2.5 mm

FinishPainted, light-grey, smooth RAL 7035 ornatural colour anodised (edges, polished)

Supply schedule1 Front panel sectionMounting material(plastic lock washers and special screws)

BGT00122_E

BGT00123_E

EMC Front Panel Section, 3 and 6 HUW H D HU/U h d Model Order no. UP Price4 HP 3 02.340.087.1 1 unit4 HP 6 02.340.105.1 1 unit6 HP 3 02.340.089.1 1 unit6 HP 6 02.340.107.1 1 unit8 HP 3 02.340.091.1 1 unit8 HP 6 02.340.109.1 1 unit10 HP 3 02.340.093.1 1 unit10 HP 6 02.340.111.1 1 unit12 HP 3 02.340.094.1 1 unit12 HP 6 02.340.112.1 1 unit21 HP 3 02.340.097.1 1 unit21 HP 6 02.340.115.1 1 unit

- Sealing between front panel sections- Side bonding of the front panel section to

the side panel - Front panel section centered with locating

pin

MaterialUp to 12 HP: extruded aluminiumFrom 21 HP: aluminium plate, 2-piece,with recessed U-shaped bracket

FinishPowder-coated, light-grey, smoothRAL 7035Contact points, polished

Supply schedule1 Front panel section1 EMC SpringMounting material (metal lock washersand special screws)

BGT00292_E

BGT00137_E

Note: Other models available onrequest!

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 138

Page 149: Shkaf Knurr Electronics e

by knürr

139

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Front Panel SectionWith fixed handleW H D HU/U h d Model Order no. UP Price

4 HP 3 EMC 02.340.340.1 1 unit6 HP 3 EMC 02.340.342.1 1 unit8 HP 3 EMC 02.340.344.1 1 unit

10 HP 3 EMC 02.340.346.1 1 unit12 HP 3 EMC 02.340.447.1 1 unit14 HP 3 EMC 02.340.448.1 1 unit

4 HP 6 EMC 02.340.350.1 1 unit6 HP 6 EMC 02.340.352.1 1 unit8 HP 6 EMC 02.340.354.1 1 unit

10 HP 6 EMC 02.340.356.1 1 unit12 HP 6 EMC 02.340.357.1 1 unit14 HP 6 EMC 02.340.358.1 1 unit

- With handle and printed circuit board holder (3 and 6 HU)

- Handle cover can be engraved

MaterialFront panelExtruded aluminium with stainless steelspringHandle: plastic

FinishPowder-coated, light-grey, smoothRAL 7035Contact points, polishedHandle: RAL 5008Handle cover, RAL 9006 (white aluminium)

Supply schedule1 Front panel2 Handles (with 3 HU only 1 handle)2 Printed circuit board holders (with 3 HU

only 1 printed circuit board holder)1 EMC springMounting material

MIC00038_E

BGT00069_E

Front Panel SectionWith push-pull tool (in accordance with IEEE 1101.10)W H D HU/U h d Model Order no. UP Price19.98 3 02.340.610.1 1 unit40.3 3 02.340.611.1 1 unit

19.98 6 02.340.615.1 1 unit40.3 6 02.340.616.1 1 unit

MaterialFront panel, extruded aluminium withstainless steel spring

FinishPainted, light-grey, smooth RAL 7035Contact points, polishedPush-pull tools, grey-blue, RAL 5008

Supply schedule1 Front panel2 Push-pull tools,

(3 HU: 1 unit)1 Printed circuit board holder (with 3 HU)1 EMC Spring6 Coding pins (with 3 HU: 3 units)2 Covers (with 3 HU: 1 unit)Mounting material

How suppliedFlat-packed kit

MIC00041_E

Note: Other models availbale onrequest!

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 139

Page 150: Shkaf Knurr Electronics e

by knürr

140

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Front Panel SectionsIn accordance with IEEE1101.10 for hot-swap applicationsW H D HU/U w Model Order no. UP Price4 HP 112.7 3 19.98 02.340.612.1 1 unit8 HP 112.7 3 40.30 02.340.613.1 1 unit4 HP 246.1 6 19.98 02.340.617.1 1 unit8 HP 246.1 6 40.30 02.340.618.1 1 unit

MaterialFront panel, extruded aluminium

FinishVisible surfacePainted light-grey, RAL 7035, smoothRear panel, polished

Supply scheduleEMC Front panelMounting material (with 8 HP)

How suppliedFlat-packed kit

NotePlease order required handles extra

- Interlockable, with mounting option formicroswitch

MaterialHandle body, plasticPrinted circuit board holder, die-cast zincEMC Spring, stainless steel

FinishHandle, blackInterlock, grey

Supply scheduleHandle, bottomHandle, top (with 6U)Printed circuit board holder (with 3U)EMC SpringMounting material

How suppliedFlat-packed kit

Push-Pull Tool, Standard Hot-SwapW H D HU/U w Model Order no. UP Price

3 02.340.601.1 1 unit6 02.340.602.1 1 unit

- Interlockable, with mounting option formicroswitch, complete for front panel

MaterialHandle body, plasticPrinted circuit board holder, die-cast zincEMC Spring, stainless steel

FinishHandle, blackInterlock, grey

Supply scheduleHandle, bottomHandle, top (with 6U)Printed circuit board holder (with 3U)EMC SpringMounting material

How suppliedFlat-packed kit

Push-Pull Tool, Telecom Hot-SwapW H D HU/U w Model Order no. UP Price

3 02.340.603.1 1 unit6 02.340.604.1 1 unit

BGT20038_E

BGT20035_E

BGT20036_E

Microswitch for Hot-Swap ApplicationsW H D HU/U w h d Model Order no. UP Price

02.340.609.1 1 unit

Microswitch, fully pre-configured, Molexconnector

Other front panel components and custo-mer-specific front panel models availableon request

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 140

Page 151: Shkaf Knurr Electronics e

by knürr

141

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

- For fixing standard trade disk drives on themodular chassis

MaterialAluminium retaining plate, 1 mmStandard front panel: aluminium 2.5 mmEMC Model: up to 12 HP, extruded alumi-nium, from 32 HP, aluminium plate, 2-piece, powder-coated, light-grey, RAL 7035, smooth, contact points, polished

Supply schedule1 Retaining plate1 Front panelMounting material

MIC00074_E

BGT80003_E

Disk Drive ChassisW H D HU/U h d Model / Front panel cutout Order no. UP Price

8 HP 3 1x31/2“ standard / 26x102 / 02.340.490.1 1 unit8 HP 3 1x31/2“ EMC / 26x102 / 02.340.620.1 1 unit8 HP 3 1x31/2“ standard / without / 02.340.491.1 1 unit8 HP 3 1x31/2“ EMC / without / 02.340.621.1 1 unit

12 HP 3 1x31/2“ standard / 42x102 / 02.340.492.1 1 unit12 HP 3 1x31/2“ EMC / 42x102 / 02.340.622.1 1 unit12 HP 3 1x31/2“ standard / without / 02.340.493.1 1 unit12 HP 3 1x31/2“ EMC / without / 02.340.623.1 1 unit

8 HP 6 1/2x31/2“ standard / 26x102 02.340.509.1 1 unit8 HP 6 1/2x31/2“ EMC / 26 x 102 02.340.628.1 1 unit

32 HP 6 2/4x51/4“ standard / 147 x 85 02.340.520.1 1 unit32 HP 6 2/4x51/4“ EMC / 147 x 85 02.340.630.1 1 unit

Note: Other models availbale onrequest!

Front Panel Mounting SetW H D HU/U h d Model Order no. UP Price

lock washer, plastic 02.352.301.9 10 unitslock washer, metal 02.352.303.9 10 unitslock washer, metal / EMC 02.340.485.9 10 units

Supply schedule10 Knurled screws10 Lock washers, can be used with tapped

strip or sliding nut (not with EMC version)

Front Panel Mounting SetW H D HU/U h d Model Order no. UP Price

lock washer, plastic 02.352.302.9 10 unitslock washer, metal 02.352.304.9 10 unitslock washer, metal/EMC 02.340.486.9 10 units

Supply schedule10 Lock washers

(not with EMC version)10 Special screws, can be used with

tapped strip or sliding nut

BGT00227_E

BGT00226_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 141

Page 152: Shkaf Knurr Electronics e

by knürr

142

EUR00021_E

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

CassettesW H D HU/U h d Model Order no. UP Price

6 172.2 3 standard 02.340.450.1 1 unit8 172.2 3 standard 02.340.451.1 1 unit

10 172.2 3 standard 02.340.453.1 1 unit12 172.2 3 standard 02.340.454.1 1 unit14 172.2 3 standard 02.340.455.1 1 unit21 172.2 3 standard 02.340.656.1 1 unit28 172.2 3 standard 02.340.657.1 1 unit42 172.2 3 standard 02.340.658.1 1 unit

12 172.2 6 standard 02.340.700.1 1 unit21 172.2 6 standard 02.340.701.1 1 unit28 172.2 6 standard 02.340.702.1 1 unit42 172.2 6 standard 02.340.703.1 1 unit

6 172.2 6 standard 02.340.452.1 1 unit8 172.2 6 standard 02.340.456.1 1 unit

MaterialComponent side, sheet steel cover, zincpassivatedSolder side, aluminium extrusionFront panel, standard: aluminium, 2.5 mm

FinishFront panel: powder-coated, light-grey,smooth, RAL 7035

Supply schedule1 Front panel with handle1 Side extrusion (anodised)1 Side cover (zinc passivated)1 Rear panel, polished

(2 rear panels with 6 HU)Mounting material

How suppliedFlat-packed kit

MIC00080_E

MIC00081_E

BGT00284_E

Note: Other models available onrequest!

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 142

Page 153: Shkaf Knurr Electronics e

by knürr

143

ELECTRONIC ENCLOSURES

Dimensions in mm: W = Width, H = Height, D = Depth, a1,a2, a3 = Mounting dimensions for front panels,w = Installation width, h1, h2, h3 = Clear distance between the extrusions, d = Useful enclosure depth,1 HU/U = 44.45, 1 HP = 5.08 mm, UP = Unit of packaging

Card GuideW H D HU/U h d Model Order no. UP Price

02.300.130.9 1 unit

-For printed circuit board guide in the cassette

Supply schedule1 Card guide

Plug BracketW H D HU/U h d Model Order no. UP Price9.18 2 02.300.131.9 1 unit9.18 10 02.300.201.9 1 unit

- For mounting female connectors (DIN 41 612) in the cassette

Material1.5 mm sheet steel

FinishZinc passivated, white

Supply schedule1 Plug bracket

Mounting BracketW H D HU/U h d Model Order no. UP Price

02.300.181.9 1 set

- Mounting DIN 41612 male connectors in thecassette

Material1.5 Sheet steel

How supplied1 Set of 5 pairs

EUR00023_E

BGT00266_E

EUR00030_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 143

Page 154: Shkaf Knurr Electronics e

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 144

Page 155: Shkaf Knurr Electronics e

Strong Points and technical details Page 146Product Page 147

CPCI, VME, VME 64x Bus Systems

CPCI, VME, VME 64x

by knürr

145

ELECTRONIC INTEGRATION

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 145

Page 156: Shkaf Knurr Electronics e

by knürr

146

ELECTRONIC INTEGRATION

With the EMC compatible struc-ture of the primus systems, weprovide you with the basis forcompliance with legally stipula-ted regulations.A variety of pre-assembled, wiredand tested standard systems areavailable to choose from. Themodular structure also enablesconfiguration for specific systemapplications.

Ventilation concepts specificallydesigned for your applicationsserve to provide specific coolingfor electronics and disk drivesystems. The filter mats can alsobe changed from the front duringrunning operation.Speed controlled fans keep noiselevels to a minimum.

The monitoring module watchesover system functions and fans,generates the VME bus signals,and gives advance warning ofdeviations. A system crash isconsequently avoided in goodtime.

3

2

1 VME64x / CompactPCI:The mechanical structure inaccordance with IEEE 1101.10enables easy push-in / pull-out ofhigh-pole connectors.

The direct bonding of the back-plane with the enclosure enhan-ces the shielding effect.An earth disconnection can bealternatively made with the samebackplane, this merely requiresselecting different screwingpoints. This procedure avoidsdouble storage.

Automatic electric daisy chainingmakes it easier to swap overdaughter cards. The time-consu-ming positioning of jumpers isdispensed with and errors withservice and configuration areprevented.

By using power supplies withauto range input (alpha 400W/600 W) only one system isrequired for international opera-tion, regardless of the mains vol-tage. The approbation makes cer-tification easier. The power factorcorrection avoids reactions to themains and enables the safe ope-ration of connected equipment.

Redundant power suppliesincrease the operating safety ofthe overall system, even in theevent of a power failure. Thedefective PSU can be changedduring the operation (HotSwap).

The mechanical structure inaccordance with IEEE 1101.10and 1101.11 enables the straight-forward push-in, pull-out of high-pole connectors. Coding preventsmix-ups with already integratedcards. The ESD spring preventsthe system from being damagedby electro-static discharges.

9

8

7

6

5

4

Electronic IntegrationStrong points

BGT00006_E1

BGT00270_E2

BGT00311_E3

BGT00271_E4

BGT00008_E5

BGT00009_E5

BGT00007_E6

BGT000011_E7

BGT00006_E8

BGT000298_E9

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 146

Page 157: Shkaf Knurr Electronics e

by knürr

147

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightS = Number of slots, Pmax = Power supply wattage

CompactPCI System Chassis, 3 HUW H S HU/U A1 A2 Pmax Model Order no. UP Price

8 3 180 W 04.100.353.1 1 unit

- EMC Installation in accordance with IEEE1101.10

- Vertical installation of 8 daughter cards 3 HU / 4 HP

- High-speed backplane, 3 HU, 8 slot (J1, J2)- System slot, right, no loss of plug-in space

with overwide CPU board- Power supply up to 50 % without derating- Ventilation with perforated covers

FinishModular chassis, sheet steel, zinc passi-vated 19” Adapter and EMC front panel section,powder-coated, RAL 7035 light-grey,smooth

BGT00312_E

Supply schedule- EMC Modular chassis, primus 3 HU,

depth 283 mm, covers perforated- EMC Rear panel- Backplane CompactPCI™ 3 HU, 8 slot,

system slot, rightCompact PCI power supply 180 WWide-range input (230 / 115 VAC; 50 / 60 Hz)+ 3.3 V / 14 A+ 5 V / 20 A+12 V / 2 A-12 V / 1 A

- Mains input filter with switch- Card guides, IEEE NT 160 with ESD

spring and coding adapter

How suppliedFully assembled, wired and tested

CompactPCI System Chassis, 6 HUWith REAR I / 0W H S HU/U A1 A2 Pmax Model Order no. UP Price

8 6 2 x 350 W 04.100.356.1 1 unit

- Redundant power supplies for increasedoperating safety

- EMC Installation in accordance with IEEE1101.10 / 1101.11

- Vertical installation of 8 daughter cards 6 HU / 4 HP

- High-speed backplane 6 HU, 8 slot (J1–J5)- System slot, right, no loss of plug-in space

with overwide CPU board- Rear side installation option of REAR I / 0

boards (80 mm)- Ventilation with perforated covers

FinishModular chassis, sheet steel, zinc passi-vated 19” Adapter and EMC front panel section,powder-coated, RAL 7035 light-grey,smoothHandles, powder-coated, RAL 5008 grey-blue

BGT00316_E

Supply schedule- EMC Modular chassis, primus 6 HU,

depth 283 mm, covers perforated- 2 Handles- Backplane CompactPCI™ 6 HU, 8 slot,

system slot, rightCompact PCI power supply 180 WWide-range input (230 / 115 VAC; 50 / 60 Hz), redundant and hot-swapcapable+ 3.3 V / 25 A+ 5 V / 40 A+12 V / 9 A-12 V / 0.2 A

- Mains input filter with switch- Card guides, IEEE NT 160 / 80 with ESD

spring and coding adapter- EMC Front panel sections

How suppliedFully assembled, wired and tested

Note: Other configurations and modelsavailable on request!

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 147

Page 158: Shkaf Knurr Electronics e

by knürr

148

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightS = Number of slots, Pmax = Power supply wattage

Note: Other configurations and modelsavailable on request!

CompactPCI System Chassis, 5 HUW H S HU/U A1 A2 Pmax Model Order no. UP Price

8 5 250 W 04.100.352.1 1 unit

- EMC Installation in accordance with IEEE1101.10

- Horizontal installation of 8 daughter cards 6 HU / 4 HP

- Diagonal airflow with integrated air filter

- Compact PCI backplane 6 HU (J1–J5)- Monitoring module with keyswitch and reset

button protected against operator error - Connecting cable for disk drives- Forced ventilation with integrated fan

FinishModular chassis, sheet steel, zinc passivated19” Adapter and EMC front panel sec-tions, powder-coated, RAL 7035 light-grey, smoothHandles, powder-coated, RAL 5008 grey-blue

BGT00321_E

Supply schedule- EMC Modular chassis, primus 5 HU,

depth 403 mm, covers closed- EMC Rear panel- 2 Handles- Backplane CompactPCI™, 6 HU, 8 slot,

system slot rightATX Power supply 250 WWide-range input (230 / 115 VAC; 50 / 60 Hz)+ 3.3 V / 14 A+ 5 V / 23 A– 5 V / 0.5 A+ 12 V / 9 A– 12 V / 0.5 A

- Monitoring module with keyswitch andreset button in EMC front panel section,4 HP

- EMC Front panel section, 9 HP, perforated, with air filter

- Air baffle- Fan, 12 VDC, temperature controlled

and failure monitored- Cable harness- Connection cable for disk drive- Card guides, IEEE 1101.10 with ESD

spring and coding adapter

How suppliedFully assembled, wired and tested

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 148

Page 159: Shkaf Knurr Electronics e

by knürr

149

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightS = Number of slots, Pmax = Power supply wattage

CompactPCI BackplaneW H S HU/U A1 A2 Pmax Model Order no. UP Price

4 3 16 04.100.474.9 1 unit6 3 24 04.100.476.9 1 unit8 3 36 04.100.478.9 1 unit5 6 20 04.100.465.9 1 unit6 6 24 04.100.466.9 1 unit8 6 36 04.100.468.9 1 unit

- Complies with PICMG Compact PCI Spec2.0, Rev 3.0

- Minimum crosstalk with optimised layout in10-layer multilayer

- Hot-swap capable- System slots, right, enable use of all plug

spaces- Electrical feed via type M connector,

Positronic P47 and via Powerpack (ATX, PS/2, FastOn)

- Minimised Clock-Skew-Design- Direct grounding contact via contact surfa-

ces, full equipping in accordance withCompactPCI specification with metricconnectors

- J1 - J5 (6 HU) and J1 - J2 (3 HU)

BGT00323_E

Note- Clock frequency, 33 / 66 MHz- Transmission mode, 32 / 64 Bit- Impedance, 65 W ± 10%- Resistance of the signal lines < 70 m W

/ Slot- Connector, mechanical lifetime IEC 917

/ IEC 1076-4-101 / 400 withdrawal cycles- Operating temperature -25°C – +85°C- Storage temperature -55°C – +85°C- Climatic category (IEC 68/1) 25 / 085 /

21- Combustibility: LP, connector,

resistance networks, ceramic capaci-tors, UL 94 V-0, electrolytic capacitors,UL 94 V-1Integrated circuits, UL 492

- Vibration:In accordance with DIN 41 640 part 15 ,5 g rms: 10 Hz – 500 HzImpact (10 impacts per axes x, y, z) 50 g, 6 msNegative pressure / height (maximum voltage 12 V) No restriction

- 10-layer stripline

Supply schedule1 CompactPCI backplane

Note: Other configurations and modelsavailable on request!

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 149

Page 160: Shkaf Knurr Electronics e

by knürr

150

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightS = Number of slots, Pmax = Power supply wattage

Note: Other configurations and modelsavailbale on request!

VME64x System ChassisW H S HU/U A1 A2 Pmax Model Order no. UP Price

21 8 600 W 04.100.270.1 1 unit

- EMC Installation in accordance with IEEE1101.10

- Rear side installation of I/0 boards and frontpanel sections (6 HU, maximum 20 HP)

- Diagonal airflow with speed-controlled andfailure monitered fans

- Backplane VME64x with automatic, electricdaisy chain

- Monitoring module with keyswitch and resetbutton protected against operator errors

- Connecting cable for disk drives- Integrated ventilation solution

FinishModular chassis, sheet steel, zinc passivated19” Adapter and EMC front panel sec-tions, powder-coated, RAL 7035 light-grey, smoothHandles, powder-coated, RAL 5008 grey-blue

BGT00271_E

Supply schedule- EMC modular chassis, primus 8 HU,

depth 403 mm, cover plate closed- 2 Handles- VME64x backplane 6 HU, with JO,

21 slot- Power supply wide-range input

(230 / 115 VAC; 50 / 60 Hz)alpha 600+ 3.3 V / 25 A+ 5 V / 60 A+ 12 V / 8 A– 12 V / 8 A

- Monitoring module with keyswitch andreset button, EMC front panel section, 1 HU, 84 HP

- EMC Front panel section, 1 HU, 84 HP,perforated with air filter

- Air baffle- Fans, 12 VDC, temperature controlled

and failure monitored- Euro plug 10 A, with integrated mains

filter and mains switch- Cable harness- Connection cable for disk drives- Card guides with ESD spring

How suppliedFully assembled, wired and tested

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 150

Page 161: Shkaf Knurr Electronics e

by knürr

151

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightS = Number of slots, Pmax = Power supply wattage

VME System Chassis, 3 HU, 5 SlotW H S HU/U A1 A2 Pmax Model Order no. UP Price

5 3 250 W 04.100.220.1 1 unit

- EMC Installation- Horizontal installation of 5 VME daughter

cards, 6 HU/4 HP- Diagonal airflow with air filter and fans,

speed-controlled and fault monitered- Monolythic backplane with automatic

electric daisy chain - Prepared for installing disk drive cassettes,

3 HU- Monitoring module with keyswitch and reset

button protected against operator errors- Connecting cable for disk drives

FinishModular chassis, sheet steel, zinc passivated19” Adapter and EMC front panel sections, powder-coated, RAL 7035 light-grey, smoothHandles, powder-coated, RAL 5008 grey-blue, textured

BGT00235_E

Supply schedule1 EMC Modular chassis primus 3 HU,depth 403 mm, cover plate closed- EMC Rear panel- Handles- VME Backplane, 5 slot, monolithic- PSU, 250 W - Power supply wide-range input

(230 / 115 VAC; 50 / 60 Hz)AT 250 W+ 5 V / 23 A+ 12 V / 9 A– 12 V / 0.5 A

- Powerfail module- Monitoring module with keyswitch and

reset button in EMC front panel section,4 HP

- EMC Front panel section, 3 HU / 9 HP,perforated with air filter

- Air filter- Fans, 12 VDC, temperature regulated

and fault monitered- Cable harness- Connecting cable for disk drives- Card guides with ESD spring

How suppliedFully assembled, wired and tested

VME System Chassis, 3 / 6 HUW H S HU/U A1 A2 Pmax Model Order no. UP Price

20 3 80 0 600 W 04.100.232.1 1 unit15 6 60 20 400 W 04.100.251.1 1 unit20 6 80 0 600 W 04.100.252.1 1 unit

- EMC Installation- Vertical installation of 5 VME daughter

cards, 3 and 6 HU- Vertical vent airflow- Backplane with automatic electric daisy

chain - Monitoring module with keyswitch and reset

button protected against operator errors - Connecting cable for disk drives- Easy service access with hinged rear panel- Ventilation with perforated cover plate

FinishModular chassis, sheet steel, zinc passivated19” Adapter and EMC front panel sections, powder-coated, RAL 7035 light-grey, smoothHandles, powder-coated, RAL 5008 grey-blue, textured

BGT00235_ESupply schedule- EMC Modular chassis primus 3 and

6 HU, depth 343 mm, cover plate perfo-rated

- EMC Rear panel- Handles- VME Backplane, monolithic- Power supply wide-range input

(230 / 115 VAC; 50 / 60 Hz)alpha 600 W (15 slot)+ 5 V / 60 A+ 12 V / 6 A– 12 V / 6 Aand alpha 600 W (20 slot)+ 5 V / 80 A+ 12 V / 8 A– 12 V / 8 A

- Euro plug with integrated mains filterand mains switch

- Monitoring module with keyswitch andreset button in EMC front panel section,3 and 6 HU, 4 HP

- Cable harness- Connecting cable for disk drives- Card guides with ESD spring

How suppliedFully assembled, wired and tested

Note: Other configurations and modelsavailbale on request!

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 151

Page 162: Shkaf Knurr Electronics e

by knürr

152

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightS = Number of slots, Pmax = Power supply wattage

VME System Chassis, 5 / 8 HUW H S HU/U A1 A2 Pmax Model Order no. UP Price

21 5 0 0 600 W 04.100.243.1 1 unit15 8 60 24 400 W 04.100.261.1 1 unit21 8 84 0 600 W 04.100.263.1 1 unit

- EMC Installation- Vertical installation of 5 VME daughter

cards, 3 and 6 HU- Diagonal airflow with integrated air filter

and speed controlled and fault monitoredfans

- Backplane with automatic electric daisychain

- Monitoring module with keyswitch and resetbutton protected against operator errors

- Connection cable for disk drive

FinishModular chassis, sheet steel, zinc passivated19” Adapter and EMC front panel sections, powder-coated, RAL 7035 light-grey, smoothHandle: powder-coated, RAL 5008 grey-blue, textured

Supply schedule- EMC Modular chassis, primus 5 and

8 HU, depth 403 mm, covers closed- EMC Rear panel- Handles- VME Backplane

BGT00235_E- Power supply wide-range input

(230 / 115 VAC; 60 Hz)alpha 400 W (15 slot) + 5 V / 60 A+ 12 V / 6 A– 12 V / 6 Aand alpha 600 W (21 slot)+ 5 V / 80 A+ 12 V / 8 A– 12 V / 8 A

- Monitoring module with keyswitch andreset button in EMC front panel section

- EMC front panel section, 1 HU, 84 HP,perforated with air filter

- Air baffle- Fans, 12 VDC, temperature controlled

and fault monitored- Euro plug, 10 A with integrated mains

filter uand mains switch- Cable harness- Connection cable for disk drive- Guide rails with ESD spring

How suppliedFully assembled, wired and tested

VME System Chassis, I / 0With recessed card spaceW H S HU/U A1 A2 Pmax Model Order no. UP Price

15 8 60 24 400 W 04.100.265.1 1 unit21 8 84 0 600 W 04.100.266.1 1 unit

- EMC Installation- Recessed installation of VME daughter

cards, 6 HU- Rear side installation of I/O boards and front

panel section ( 6 HU, max. 48 HP, 20 HPwith 21 slot)

- Diagonal vent airflow with integrated air fil-ter and speed controlled and fault monitoredfans

- Backplane with automatic electric daisychain

- Monitoring module with keyswitch and resetbutton protected against operator errors

- Connection cable for disk drive

FinishModular chassis, sheet steel, zinc passivated19” Adapter and EMC front panel sections, powder-coated, RAL 7035 light-grey, smoothHandle: powder-coated, RAL 5008 grey-blue, textured

Supply schedule- EMC Modular chassis primus 8 HU,

depth 403 mm, covers closed- EMC Hinged front panel 8 HU, 84 HP

BGT00273_E

- Air filter- EMC Rear panel- Handles- VME Backplane - Power supply wide-range input

(230 / 115 VAC; 60 Hz)alpha 400 W (15 slot) + 5 V / 60 A+ 12 V / 6 A– 12 V / 6 Aand alpha 600 W (21 slot)+ 5 V / 80 A+ 12 V / 8 A– 12 V / 8 A

- Monitoring module with keyswitch andreset button in EMC front panel section

- Fans, 12 VDC, temperature controlledand fault monitored

- Euro plug, 10 A with integrated mainsfilter and mains switch

- Cable harness- Connection cable for disk drive- Card guides with ESD spring

How suppliedFully assembled, wired and tested

Note: Other configurations and modelsavailbale on request!

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 152

Page 163: Shkaf Knurr Electronics e

by knürr

153

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightS = Number of slots, Pmax = Power supply wattage

VME 64x BackplaneW H S HU/U A1 A2 Pmax Model Order no. UP Price100.1 5 6 + 1 20 VME64x 04.100.065.9 1 unit140.7 7 6 + 1 28 VME64x 04.100.067.9 1 unit242.3 12 6 + 1 48 VME64x 04.100.072.9 1 unit303.3 15 6 + 1 60 VME64x 04.100.075.9 1 unit404.9 20 6 + 1 80 VME64x 04.100.080.9 1 unit452.2 21 6 + 1 84 VME64x 04.100.081.9 1 unit

- Complies with specification VME 64x, draft1.8

- Automatic electric daisy chain- Direct earth contact with cross rail- Low voltage drops with monolithic structure - Decoupling capacitors for ±12 V- VME Bus utility signals can be tapped via

cable plug- Internal passive termination- Increases shielding effect with additional

GND pins- Increased I/O connection options with 5

series connectors, J1 / J2 and metricconnector JO

- Height 7 HU

BGT00299_E Note- Maximum data transmission rate, 60

Mbyte/s (120 Mbyte/s MBLT)- Daisy chain, automatic electric- Impedance 50 - 54 Ω- Ohmic resistance of the signal lines <

100 m Ω- Termination, passive, inboard- Power consumption, 1.5 A- Power feed via power supply bars - Connector mechanical lifetime, quality

level 2, 400 withdrawal cycles - Operating temperature -25°C – +85°C- Storage temperature -55°C – +85°C- Climatic category (IEC 68/1) 25 / 085 /

21- Combustibility: LP, connector, resi-

stance networks, ceramic capacitors, UL94 V-0, electrolytic capacitors, UL 94 V-1Integrated circuits, UL 492

- Vibration:In accordace with DIN 41 640 part 15, 5 g rms10 Hz – 500 HzImpact (10 impacts per axes x, y, z) 100 g, 6 ms

- Negative pressure / height(maximum voltage 12 V) no restriction

- 10-layer stripline

Supply schedule1 VME 64x Backplane, monolithic

Note: Other configurations and modelsavailbale on request!

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 153

Page 164: Shkaf Knurr Electronics e

by knürr

154

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightS = Number of slots, Pmax = Power supply wattage

Other configurations and models available on request!

VME BackplaneW H S HU/U A1 A2 Pmax Model Order no. UP Price100.1 261.6 5 6 20 monolithic 04.100.005.9 1 unit140.7 261.6 7 6 28 monolithic 04.100.007.9 1 unit242.3 261.6 12 6 48 monolithic 04.100.012.9 1 unit303.3 261.6 15 6 60 monolithic 04.100.015.9 1 unit404.9 261.6 20 6 80 monolithic 04.100.020.9 1 unit452.2 261.6 21 6 84 monolithic 04.100.021.9 1 unit

100.1 129.6 5 3 20 J1 04.100.025.9 1 unit140.7 129.6 7 3 28 J1 04.100.027.9 1 unit242.3 129.6 12 3 48 J1 04.100.032.9 1 unit303.3 129.6 15 3 60 J1 04.100.035.9 1 unit404.9 129.6 20 3 80 J1 04.100.040.9 1 unit452.2 129.6 21 3 84 J1 04.100.041.9 1 unit

- Complies with VME specification Rev. c1- Automatic electric daisy chain- Direct earth contact with cross rail- Low voltage drops with monolithic structure - Decoupling capacitors for ±12 V- VME Bus utility signals can be tapped via

cable plug- Internal passive termination

BGT00012_E

Note- Maximum data transmission rate, 60

Mbyte/s (120 Mbyte/s MBLT)- Daisy chain, automatic electric- Impedance 65 Ω ± 5 Ω- Ohmic resistance of the signal lines < 60

m Ω / slot- Termination, passive, inboard- Power consumption, 1.3 A (0.9 A/J1)- Power feed bolts, 5/7 slot - Connector mechanical lifetime, quality

level 2, 400 withdrawal cycles - Operating temperature -25°C – +85°C- Storage temperature -55°C – +85°C- Climatic category (IEC 68/1) 25 / 085 / 21- Combustibility: LP, connector, resi-

stance networks, ceramic capacitors UL94 V-0, electrolytic capacitors UL 94 V-1Integrated circuits, UL 492

- Vibration:In accordace with DIN 41 640 part 15, 5 g rms: 10 Hz – 500 HzImpact (10 impacts per axes x, y, z) 100 g, 6 ms

- Negative pressure / height(maximum voltage 12 V) no restriction

Supply schedule1 VME Backplane

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 154

Page 165: Shkaf Knurr Electronics e

by knürr

155

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightS = Number of slots, Pmax = Power supply wattage

Monitoring ModuleW H S HU/U A1 A2 Pmax Model Order no. UP Price

3 4 04.100.160.1 1 unit6 4 04.100.161.1 1 unit1 84 04.100.162.1 1 unit

- Monitors and signals the operating voltage- Generates the VME bus signals, ACFAIL and

SYSRESET- Signals the VME bus signals, SYSFAIL

and fan failure (FANFAIL)- Reset button recessed installed, protected

against operator errors Keyswitch prevents unauthorised shut downof the system

FinishFront panel section, powder-coated, RAL 7035 light-grey, smooth

BGT00252_ESupply schedule1 Monitoring module1 Front panel section- Specification:Displays:- Vcc LED, two-coloured,

green within the tolerance,red outside the toleranceTolerance field can be individually set with jumper (VME, ± 2.5%, ± 5%)(factory, ± 2.5%)+12 V LED one-colour, green- 12 V LED one-colour, redSYSFAIL LED, one-colour, redFANFAIL LED, one-colour, red

- VME bus signalsInput Mains failure signal, Powerfail,from power supplyOutput ACFAIL and SYSRESET in accordance with VME busspecification, FANFAILInput TTL open collectorhigh = oklow = fail

- Reset buttonGenerates manual SYSRESETDebouncedRecessed installed, consequently pro-tected against operator errors

- KeyswitchOption 1 Direct 2-pole switching-off of themains voltage Option 2 Switching off of the power supplyvia the INHIBIT signal(factory-set)

- ConnectionPlug AMP MODU MTEfor flat band cable

How suppliedAssembled

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 155

Page 166: Shkaf Knurr Electronics e

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 156

Page 167: Shkaf Knurr Electronics e

Product Page 158

Power Supply Units

Power Supplies

by knürr

157

ELECTRONIC INTEGRATION

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 157

Page 168: Shkaf Knurr Electronics e

by knürr

158

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightS = Number of slots, Pmax = Power supply wattage

VME Bus Cassette PSUW H S HU/U A1 A2 Pmax Model Order no. UP Price

6 12 270 00.220.065.1 1 unit

- Compact design, 270 watt in 6 HU/12 HP- Power factor correction- VME Signals ACFAIL and SYSRESET- High level of efficiency- Operation up to 55°C with free convection- No forced ventilation required

FinishFront panel, painted, light-grey RAL 7035

HEI00218_E

NoteWide-range input:AC 88 - 264 VAC / 47 - 63 HzStarting current:8 x InputLevel of efficiency: 88% typicalDisplays: 3 LED green for output voltagesVME Signals: ACFAIL SYSRESETConnector: 2 units, DIN 41612 H15Environment temperature: 0° - +55°Cwith free convection

Supply schedule1 Cassette PSU

CompactPCI PSU, 180 WW H S HU/U A1 A2 Pmax Model Order no. UP Price

3 12 180 AC / DC 00.220.066.1 1 unit

- Compact design, 180 watt in 3 HU/12 HP- EMC Equitable design- EMC Front panel- CompactPCI signals- Operating display- No forced ventilation required

HEI00219_E

Note- Wide-range input

187 – 264 VAC50 / 60 Hz

- Efficiency:82 % typical

- Displays:4 LED green for output voltages

- Connector:DIN 41612 type M

- Environment temperature:0° … + 55° C with free convection

Supply schedule1 Cassette PSU

CompactPCI Cassette PSUW H S HU/U A1 A2 Pmax Model Order no. UP Price

350 AC / DC 00.220.067.1 1 unit350 DC / DC 00.220.068.1 1 unit

- Compact design, 350 watt in 6 HU/8 HP- Redundant operation possible- Hot-swap capable- Power factor correction- EMC Equitable design- EMC Front panel with push-in / pull-out

tools in accordance with IEEE 1101.10- Wide-range input

FinishFront panel, painted, light-grey RAL 7035

HEI00220_E

NoteMains supply: Wide-range input: AC 90 - 264 VAC / 47 - 63 HzDC 40 - 72 VDCEfficiency:75% typicalDisplay:LED green, input OKLED red, faultCompact PCI signals:EN# / INH# / DEG# / FAIL#Power factor correction:0.99 typicalEnvironment temperature:0° - +55°C with ventilation

Supply schedule1 Cassette PSU

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 158

Page 169: Shkaf Knurr Electronics e

by knürr

159

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightS = Number of slots, Pmax = Power supply wattage

Open Frame PSUW H S HU/U A1 A2 Pmax Model Order no. UP Price274.5 231.0 249.0 400 W 400 04.100.144.9 1 unit318.0 267.0 267.0 600 W 600 04.100.146.9 1 unit318.0 267.0 267.0 600 W 600 / 3.3 04.100.147.9 1 unit

- Power factor correction prevents negativereaction on the mains

- Connector systems on primary and secondary sides enable rapid integration

- Safe operation with integrated fans

BGT00013_E

BGT00251_E

Note- Approvals:

EN 60950, UC 1950, CE, UL, CSA- Interference immunity, EN 61000-4-

2/4/5, level 3Interference suppression, EN 55022 B(conducted)

- Input Mains voltage 85 - 253 VACMains frequency 47 - 63 HzEfficiency: typical 75%Mains correction < 2% ± 100% Ue

- OutputsAlpha 400+ 5 V / 60 A; + 12 V / 6 A; – 12 V / 6 AAlpha 600+ 5 V / 80 A; + 12 V / 8 A; – 12 V / 8 AAlpha 600 / 3.3.+ 3.3 V / 2 A; + 5 V / 60 A; + 12 V / 6 A; – 12 V / 6 ARipple 1%Monitoring installations Overvoltage protection 3.3 V/5 V outputMains failure backup time, 20 msSoft-start 500 msPower-fail signal Operating temperature 0 ... + 70°CMTBF 60,000 h / 50°CIntegrated ventilator

Supply schedule1 PSU

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 159

Page 170: Shkaf Knurr Electronics e

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 160

Page 171: Shkaf Knurr Electronics e

Strong Points and technical details Page 162Product Page 163Accessories Page 164

IPC Industrial PC

IPC

by knürr

161

ELECTRONIC INTEGRATION

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 161

Page 172: Shkaf Knurr Electronics e

by knürr

162

ELECTRONIC INTEGRATION

Protection rating IP 54 (front) foruse in rough surroundings.High level of processing safetywith filter change, even duringrunning operation.

Mechanics, power supply andwiring from one source as thebest possible basis for your high-grade electronics. Constructivemeasures, correct choice ofmaterials and surface protectivetreatment ensure optimum EMCproperties.

Rear panel with mounting levelrecessed to the inside protectsincoming and outgoing lines andplug contacts. Central M6 earthbolts for potential equalization.

Protection for operating elementsand storage media from unautho-rised access with lock-ablealuminium front door.

Ensured functioning of your elec-tronics with intelligent conceptwith forced ventilation. Acousticdisturbance in the lab area isavoided by using low-noise fans.

Various I/O shields, suitable forall motherboard configurations.

Specific ventilation of disk drives and hard disks by usingside positioned vent slots.

7

6

5

4

3

2

1

IPC chasseleon ATX / IPC Emshield ATXStrong points

IPC00084_E1

IPC00091_E3

IPC00042_E5

IPC00158Pfeile_E2

IPC00045_E4

IPC00106_E6

IPC00090_E7

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 162

Page 173: Shkaf Knurr Electronics e

by knürr

163

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight

IPC00120_E

IPC00118_E

IPC Emshield ATXW H S HU/U A1 A2 Pmax Model Order no. UP Price

4 300 W 02.313.480.1 1 unit

Material-Basic enclosure, cover and installationcomponents, sheet steel, zinc passivated

- Front panel, sheet steel- Front door, aluminium- Internal contact points, polished

Finish- Front panel and front door, powder-

coated, light-grey, textured RAL 7035- Handles, powder-coated, grey-blue,

textured RAL 5008

Supply scheduleBasic enclosureCoverFront panel with lockable aluminium doorFront chamber with recessedoperatingelementsVent chamber with card guideRear panel for mounting cardPower supply, ATX 300 W (230 VAC / PFC)FanFilter with filter matMounting bracket for disk drive, 3.5“, verticalAdapter for hard disk, 3.5“Disk drive frame for 3 disk drives, 5.25“SpeakerSealCard holderHandle

How supplied- Fully assembled- Fan, speaker, reset button and double

LED cabled.

IPC00080_E

IPC00081_E

IPC00115_E

IPC00095_E

IPC chasseleon ATXW H S HU/U A1 A2 Pmax Model Order no. UP Price

4 300 W 02.313.225.1 1 unit

Material- Side panels, extruded aluminium- Front panel, top and bottom cover, card

guide front, bottom panel and rearpanel, sheet steel

Finish- Side panels, internal polished, external

powder-coated, light-grey, RAL 7035- Front panel, top and bottom cover, zinc

passivated, externally powder-coated,light-grey, RAL 7035

- Card guide, front, base plate, rear panel,zinc passivated

- Handles, powder-coated, grey-blue, textured , RAL 5008

Supply scheduleSide panelBottom cover, closedTop cover, closedFront panel with lockable aluminium doorSealed front chamber with recessed ope-rating level and cutouts for 1 x 3.5” and 2x 5.25” disk drivesRear panel for card mounting, rearPower supply ATX 300 W Auto wide-range input(230/115 V) VAC, 50/60 Hz)

Fan, 100 m3/hFilter with filter matMounting panel with mounting drill holesfor all current motherboardsCross extrusion5.25” Mounting kit on shock absorbers forinstalling 3 disk drives, 5.25”Adapter for 3.5” hard diskCard guide, front3.5” Floppy mounting bracket, verticalEarthing setDouble LED, red/greenReset button19” AdapterHandleCard holder (optional)Slot coverSpeaker

How supplied- Fully assembled- Fan, speaker, reset button and double

LED cabled, cable length ca. 500 mm,including plug

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 163

Page 174: Shkaf Knurr Electronics e

by knürr

164

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight

I/O Shield for IPC Emshield ATX and IPC chasseleon ATXW H S HU/U A1 A2 Pmax Model Order no. UP Price

Type MARL 2-0 02.313.481.7 1 unit Venus, Tucson 1-0 02.313.482.7 1 unit Venus, Tucson 1-1 02.313.483.7 1 unit Venus, Tucson 1-2 02.313.484.7 1 unit Venus, Tucson 1-3 02.313.485.7 1 unit Venus, Tucson 1-4 02.313.486.7 1 unit Venus, Tucson 1-6 02.313.487.7 1 unit Tucson 1-6, RJ45 02.313.488.7 1 unit

Material / FinishSheet steel, 0.8 mm, zinc passivated

Supply schedule1 I/O Shield

Card HolderW H S HU/U A1 A2 Pmax Model Order no. UP Price

IPC chasseleon ATX 02.313.307.9 1 unit

- For securely fixing the insert card with dynamic load rating

- Easy mounting and handling- Suitable for all current card heights

Material- Crosspiece

Aluminium 2 mm- Holder

Polyamid 3 mm

Finish- Crosspiece, polished

Supply schedule1 Crosspiece with mounting bracket

12 HoldersMounting material

Slot CoverW H S HU/U A1 A2 Pmax Model Order no. UP Price

Type A / without cutout 02.313.304.7 1 unitType B / D-SUB 9-pole 02.313.300.7 1 unitType C / D-SUB 25-pole 02.313.301.7 1 unitType D / D-SUB 9+25-pole 02.313.302.7 1 unitType E / SCSI 02.313.303.7 1 unit

- Different models for covering free slots - With and without cutout

Material- Sheet steel, 1.0 mm

FinishZinc passivated, colourless chrome-plated

Supply schedule10 Slot covers

IPC80002_E

IPC00096_E

IPC00008_E

A B C D E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 164

Page 175: Shkaf Knurr Electronics e

by knürr

165

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = Depth h = Max. installation height, d = Useful depth / Chassis depthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight

Disk Drive CoverW H D HU/U d kg Model Order no. UP Price

Type 3.5” / IPC chasseleon 02.313.309.1 1 unitType 1 x 5.25” / IPC chasseleon 02.313.308.1 1 unitType 2 x 5.25” / IPC chasseleon 02.313.310.1 1 unitType 3.5” / IPC Emshield 02.313.435.7 1 unitTyp 5.25” / IPC Emshield 02.313.436.7 1 unit

- For covering unassigned disk drive spaces- Easy mounting

MaterialSheet steel, 1.0 mm

Finish- IPC chasseleon, powder-coated,

light-grey, textured, RAL 7035- IPC Emshield,

polished

Supply schedule1 Disk drive coverMounting material

IPC00009_E

IPC00098_E

IPC00050_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 165

Page 176: Shkaf Knurr Electronics e

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 166

Page 177: Shkaf Knurr Electronics e

Product Page 168

RAID Raid Systems

RAID

by knürr

167

ELECTRONIC INTEGRATION

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 167

Page 178: Shkaf Knurr Electronics e

by knürr

168

ELECTRONIC INTEGRATION

RAID Store SystemW H S HU/U A1 A2 Pmax Model Order no. UP Price84 HP 4 2x400 W 02.318.024.1 1 unit

- Installation space for maximum 8 SCA2 harddisks

- Redundant power supply 2 x 400 W- 8-Way LVDS 2 backplane- U-160 Tested- 1-3 Channels- System monitoring- Communication with SNMP- SCSI-ID Manual setting- Disk drive shuttles can be locked

FinishCovers, side panels, adapter front, frontpanel, powder-coated, textured,RAL 7035 (light-grey)- Cross extrusions, adapter rear, handles,

powder-coated, texturedRAL 5008 (grey-blue)- Rear panel, zinc passivated

Supply scheduleFully assembled with wiringWithout disk drives, controller and computer accessories

RAID Server SystemW H S HU/U A1 A2 Pmax Model Order no. UP Price84 HP 8 2x400 W 02.318.025.1 1 unit

- Installation space for maximum 8 SCA2 harddisks

- Integrated IPC chasseleon ATX- Redundant power supply 2 x 400 W- 8-Way LVDS 2 backplane- U-160 Tested- 1-3 Channels- System monitoring- Communication with SNMP- Suitable for full size ATX main board- Card installation with full installation length- Additional installation of 3 x 51/4’’ disk

drives - Front door and disk drive shuttles can be

locked- SCSI-ID Manual setting

FinishCovers, side panels, adapter front, frontpanel, powder-coated, textured,RAL 7035 (light-grey)- Cross extrusions, adapter rear, handles,

powder-coated, texturedRAL 5008 (grey-blue)- Rear panel, zinc passivated

Supply scheduleFully assembled with wiringSupply schedule without disk drives, controller and computer accessories

EMS20009_E

EMS20010_E

Mini RAIDW H S HU/U A1 A2 Pmax Model Order no. UP Price84 HP 4 2x300 W 02.318.023.1 1 unit

- Installation space for maximum 4 SCA2 harddisks

- Redundant power supply 2 x 300 W- 4-Way LVDS 2 backplane- U-160 Tested- 1 Channel- System monitoring- Communication with SNMP- Suitable for baby ATX main board- Card installation with full installation length- Additional installation of 3 x 5 1/4’’ disk

drives optional- Front door and disk drive shuttles can be

locked

FinishCovers, side panels, adapter front, frontpanel powder-coated, textured,RAL 7035 (light-grey)- Cross extrusions, adapter rear, handles,

powder-coated, texturedRAL 5008 (grey-blue)- Rear panel, zinc passivated

Supply scheduleFully assembled with wiringWithout disk drives, controller and com-puter accessories

EMS80007_E

EMS80008_E

EMS80011_E

EMS80012_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 168

Page 179: Shkaf Knurr Electronics e

by knürr

169

ELECTRONIC INTEGRATION

CD-ROM Server chasseleonW H S HU/U A1 A2 Pmax Model Order no. UP Price84 HP 4 250 W Internal controller 02.318.400.1 1 unit

External controller 02.318.401.1 1 unit

- Installation option for maximum 7 high-speed CD-ROM /DVD disk drives

- 250 W PSU- Cabling optional for internal or external

controller

FinishCovers, side panels, adapter front, frontpanel powder-coated, textured, RAL 7035light-greyCross extrusions, adapter rear, handle,powder-coated, textured, RAL 5008 grey-blueRear panel, zinc passivated

How suppliedFully assembled with cabling for up to 7CD-ROM disk drives and 1 CD-ROM controllerWithout disk drive, controller and compu-ter accessories

IPC00159_E

IPC00160_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 169

Page 180: Shkaf Knurr Electronics e

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 170

Page 181: Shkaf Knurr Electronics e

Strong Points and technical details Page 172Product Page 175

UPS Uninterruptible Power Supply

UPS

by knürr

171

ELECTRONIC INTEGRATION

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 171

Page 182: Shkaf Knurr Electronics e

by knürr

172

ELECTRONIC INTEGRATION

Safety:High-grade online and line-inter-active technology ensures safeand uninterruptible operation ofyour installations.

Efficiency:The 19” module provides highperformance in low installationspace requirement with compactdesign and modular structuring.

Forward-thinking:Our solutions grow with yourrequirements, they are flexible inbeing put into effect and can beeasily supplemented.

Modularity:The individual components of thisrange can be combined to suitrequirements and consequentlyprovide specifically customisedsolutions.

User-friendly:Wide-ranging displays and inter-active interfaces for external evaluation of status reports constantly provide the operatorwith current system information.

Uninterruptible Power SupplyStrong points

ELI00392a_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 172

Page 183: Shkaf Knurr Electronics e

by knürr

173

ELECTRONIC INTEGRATION

When the mains are stable, the lineinteractive UPS model uses itspower inverter in inverse operationto recharge the accumulator.If the mains power supply is inter-rupted, the working direction isinverted and the accumulator feedsthe power inverter. Since the conver-ter constantly monitors the mainsinput, it can respond to failures andcorrect voltage influxes quickly. Theconverter series-connected to theequipment has a filter effect to somedegree in order to react to mains fai-lure. This uninterruptible power supplytechnology is recommended formany applications, especially forthose in the PC area.

Line Interactive / Pulsar Evolution

~=

FilterInput

Output

electronic switch

static frequency changer

Battery

sensitive equipment.

Online UPS installations have theadvantage of being able to efficientlyfilter out spikes and drop-outs byconverting from alternating voltageto direct voltage and back again toalternating voltage.

Our online UPS installations arestandard equipped with interfacesthat enable unsupervised computersto be automatically switched off, andafter the network is back in operati-on, to be automatically switchedback on again.

If defects occur in the installation,caused, for example, by the aging ofthe accumulator batteries, an auto-matic bypass-switching providesbackup and direct connection to thenetwork without interruption.The operator is acoustically andoptically notified about the networkfailure.

In the event of supply failure, thebattery comes into operation inplace of the rectifier and providesthe required energy without inter-ruption for a defined time period.Online installations provide a veryhigh degree of safety and arerecommended for high-grade and

Online / Pulsar EXtreme C

Input

Output

Automatic bypass

Power inverter

Battery

Filter~=~ =

Rectifier

Filter

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 173

Page 184: Shkaf Knurr Electronics e

by knürr

174

ELECTRONIC INTEGRATION

In the event of supply failure, thebattery comes into operation inplace of the rectifier and providesthe required energy without inter-ruption for a defined time period.Online installations provide a veryhigh degree of safety and are recom-mended for high-grade and sensitiveequipment.Online UPS installations have theadvantage of being able to efficientlyfilter out spikes and drop-outs byconverting from alternating voltageto direct voltage and back again toalternating voltage.Our online UPS installations arestandard equipped with interfacesthat enable unsupervised computersto be automatically switched off, andafter the network is back in operati-on, to be automatically switchedback on again.If defects occur in the installation,caused, for example, by the aging ofthe accumulator batteries, an auto-matic bypass-switching providesbackup and direct connection to thenetwork without interruption.The operator is acoustically andoptically notified about the networkfailure.

Hot-Swap functionPulsar EXtreme enables UPSmaintenance, repair and batteryswop during running operationwithout interrupting or causingdisturbance to the power supply.

Online / Pulsar EXtreme

Input

Output

Automatic bypass

Power inverter

Battery

Filter~=~ =

Rectifier

Filter

Manual bypass / „Hot-swap“

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 174

Page 185: Shkaf Knurr Electronics e

by knürr

175

ELECTRONIC INTEGRATION

Line Interactive / Pulsar Evolution UPS800 to 3,000 VA

Compact, high-grade protection for servers, storage systems and network equipment

Pulsar Evolution, in rack or towermodel, provides the optimum powersupply availability for your system.

Compact design and highestpossible flexibility with bothassembly and installation- Ultra-flat rack model:

only 1 HU from 500 to 1,500 VAonly 2 HU from 2,200 to 3,000 VA

- Multiple installation optionsdepending on the model

Optimum availability- Power supply redundancy via

Pulsar STS- Expandable backup times with 2

HU battery modules- HF Technology with sine output- Hot-swap batteries

Advanced communication- Standard with USB and serial

interface- SNMP and Web-based

remote management- Programmable outputs for

remote and autonomy mana-gement

PUL800001_E Pulsar EvolutionA revolutionary development1500 VA, only 1 HU3000 VA, only 2 HU

Pulsar Evolution Rack800 / 1100 / 1500

Pulsar Evolution Tower2200 / 3000Model for tower or 19“ (2 HU)

PUL80002_E

PUL80003_E

113-200_eng_final.qxd 07.08.2002 15:30 Uhr Seite 175

Page 186: Shkaf Knurr Electronics e

by knürr

176

ELECTRONIC INTEGRATION

Battery charge status

1 Group: 4 output sockets2 Groups of 2 programmable out-puts

Capacity utilization

Full operating and display panel:- Normal / battery operation- Booster / fader mode- Status Powershare outputs- Battery swop / fault

Connection forEXB module

Slot for optional communications cards

Data lineprotection

Port for automatic battery extension recognition

RS232 Interface

USB Interface

Removable logo and batteryaccess

Pulsar Evolution 800 1100 1500 2200 3000Nominal power VA/W 800/560 1100/700 1500/1000 2200/1540 3000/2000

Model Combi installation, tower/2HU rack

Installation options Rack version: 19“ installation / 1 HU 19“ installation with enclosed kit

Tower configuration with stand feet

Number of IEC-320 Euro outputs 4 4 4 8 8

of these, Powershare outputs 2 2 2 2 x 2 2 x 2

EXB Battery extension module – – – 1-3 EXB

Technical characteristic dataTechnology High frequency technology, line-interactive

Automatic voltage regulation Booster/fader

Output, voltage form SINUS

Input voltage tolerance 160V/294V, programmable on 150V/294V

Frequency 50 Hz or 60 Hz, automatic network frequency recognition

Output voltage with battery use 230V (programmable at 200/220/240V))

Equipment featuresAutomatic battery test Weekly (other intervals programmable)

Exchangeable batteries (HOT-SWAP)

Standard backup time 100%/50% load (min.) 5/15 5/15 5/15 5/15 5/15

Backup time with 1* EXB 100%/50% load (min.) - - - 35/90 30/70

Cold start capability

Deep-discharging protection

UPS Driver for Windows Threshhold programming (voltage tolerance, sensitivity, battery test, ON/OFF)

Data line protection RJ45 Network protection

Communication/MonitoringCommunications interface 1x USB + 1x RS232 Interface (standard)

Communications slot for options 1, For SNMP card or status information

Power management software, Solution-Pac Local management and SNMP proxy agents for Windows 2000/NZ/98

on CD in the supply schedule Linux, Netware, OpenServer, Unixware, SUN Solaris, IBM AIX, HP UX, Compaq Tue64 etc.

Web-based monitoring XML-@gent (end 2001)

Remote indication (option) UPS Control indicator panel

StandardsSafety EN 50091-1-1/EN 60950 (RD), IEC 60950, TÜV (technical monitoring institute), GS

Electromagnetic compatability EN 50091-2, EN 50022/B, IEC 62040-2, IEC 61000-3-2, IEC 61000-3-3

Design, manufacture, logistics and service ISO 9001

Certifications CE, TÜV GS

Service scheduleExtended 3-year warranty

General characteristics data 800 1100 1500 2200 3000

Rack dimensions, W=438xHxD (mm) 44(1HU)x499 44(1HU)x522 88(2HU)x640

Weight (kg) 15.5 16 19 33.9 36.5

Weight EXB module – – – 41.9

Accessories included in the supply schedule Removable 19” support bracket, universal telescopic rails,

for 19“ versions mounting accessories, cable holder

Order no. UPS 06.100.601.1 06.100.602.1 06.100.603.1 06.100.604.1 06.100.605.1

Order no. EXB battery module 06.100.606.1

Order no. SNMP card 06.100.626.1

Order no. relay card 06.100.627.1

PulsarEvolution3000

Sta

ndar

ds,

sp

ecifi

catio

ns a

nd m

odel

s ch

ange

fro

m t

ime

to t

ime.

Sub

ject

to

tech

nica

l cha

nges

.

Pulsar Evolution Features

PUL800017_E

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 176

Page 187: Shkaf Knurr Electronics e

by knürr

177

High Performance and Reliability

CE and UL certified

Optimum availabilityPulsar EXtreme C guarantees thehighest possible availability(>99.999%) for your system.

Cold start via batteryThis function enables problem-free start of your applications,even with system power failure.

Automatic bypassIn the event of an overload or adefect, Pulsar EXtreme C swit-ches the device without interrup-tion to the mains supply.

Pulsar EXtreme C provides extensiveprotection and optimum reliability foryour system.

Wide input voltage rangeThe wide-ranging input voltage ofthe Pulsar EXtreme C of 120-276 Vreduces switching, and as a result,also reduces strain on the battery.Pulsar EXtreme C optimises thebattery lifespan and calls on thebattery to operate only when this isunavoidably neccessary, as in theevent of a power failure.

High performance battery-charging moduleThe Pulsar EXtreme C chargingmodule:- Reduces the battery’s recharging

time (80% backup time in 2hours).

- Increases the battery’s lifespan byincorporating the model-specificbattery parameters, the environ-ment temperature and batteryaging.

- Protects the battery from deep-discharging.

- Integrated power factor correc-tion, i.e. no system reaction.

- Prevents possible fault effects onthe system power supply (back-feed protection).

Pulsar EXtreme C UPS / Online700 / 1000 / 1500 VA

Pulsar EXtreme CRepresents compact designand optimum protection.

- Reliable high-performancetechnology

- Optimum availability- Advanced communication- User-friendly- Flexible and expandable

Maximum security for your server,telecommunications and networkcomponents... with minimum spacerequirement.

ELECTRONIC INTEGRATION

PUL00020_E

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 177

Page 188: Shkaf Knurr Electronics e

by knürr

178

ELECTRONIC INTEGRATION

Advanced Communications Options

Installation and integration- Tower or as 19” model- Complete 19” mounting kit

with telescopic rails and mounting material

- Quick start instructions- Easy system connection via pro-

tective contact plug

Indication and operating elementsMalfunction indications- Overload- UPS Fault- Battery fault- Status indication of the pro-

grammable line loadsNr.1 and Nr. 2

- ON/OFF- % Battery backup- Indication of the degree of

capacity utilization in %- Lamp test/buzzer OFF,

manual switching,WR/Bypass

- Operation via bypass- Operation in online mode- Battery operation

3Pulsar EXtreme C provides a fullpackage of communications soluti-ons for connecting electronic dataprocessing and monitoring systems.

Two communications interfacesThe Pulsar EXtreme C comesstandard equipped with an RS232and a USB interface, for straight-forward connection of the UPSwith a server, for, as an example:

Individual adaption of the PulsarEXtreme CBy modifying the factory-setparameters (output voltage, bat-tery test intervals, bypass opera-tion etc.) via the UPS driver soft-ware.

LAN and WAN management(SNMP/WEB) of the UPS and theconnected server via Solution-Pac.

Solution-Pac softwareSolution-Pac provides the optionof:- Information for the user.- Automatic shutdown of one or

more servers in a heterogenousnetwork.

- Remote monitoring and management of the UPS.

Additional communications slotEnables the integration of anadditional communications board(SNMP, telecommunicationsconnections etc.). UPS communi-cation becomes totally indepen-dent with these cards. For exam-ple, the user is informed aboutthe UPS status following a servershutdown.

2

1

PUL80004_E1

PUL80005_E2

PUL80006_E3

PUL80007_E3

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 178

Page 189: Shkaf Knurr Electronics e

by knürr

179

Flexible and Expandable

Hot-swap batteryThe user can change the batte-ries during the running operati-on, that is, without switching offthe equipment.

Individual management ofequipment connections viaPowershareTM

The 2 programmable connectionsenable the individual assignmentof the backup time and remoteswitching on and off for theconnected equipment.

6

5Pulsar EXtreme C meets tomorrows requirements today.

Backup times from 6 minutes toseveral hoursPulsar EXtreme C is standardequipped for at least 6 minutesbackup. Higher operating conti-nuity can be achieved with:- Up to 3 EXB battery extensions

that can be added-on duringthe running operation.

- CLA Module (high-performan-ce device) for particularly longbackup times, up to 8 hourswith full load.We are readily at your disposalfor all detailed information.

4

PUL80008_E4

PUL80009_E5

PUL00021_E6

ELECTRONIC INTEGRATION

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 179

Page 190: Shkaf Knurr Electronics e

by knürr

180

ELECTRONIC INTEGRATION

Pulsar EXtreme Features

(1) Values for 50%, 66% and 100% load

Article numbers EXtreme 700 C EXtreme 1000 C EXtreme 1500 CModel UPS EXB UPS EXB UPS EXB

06.100.620.1 06.100.623.1 06.100.621.1 06.100.624.1 06.100.622.1 06.100.625.1

Order no. SNMP card 06.100.626.1 06.100.626.1 06.100.626.1

Order no. relay card 06.100.627.1 06.100.627.1 06.100.627.1

Slot for communicationscard

RS232 and USB interfaces

2 Programmable outputs

Mains connection

ON/OFF

Operation via bypass, online mode, battery use

Status programmable connections 1+2

Light test/buzzing OFFManual switching WR/Bypass

Button for indicating the capacityutilization in %

Fault indication and battery backup

Connection for external EXB battery module

Pulsar EXtreme 700 C 1000 C 1500 CGeneralNominal power 700 VA / 490 W 1000 VA / 700 W 1500 VA / 1050 WInput voltage range 120/140/160 up to 276 V without battery support (1)Frequency range 50/60 Hz (self-detecting)Input power factor (THDI) >0.95 (< 5%)Output voltage, sine 200/208/220/230/240 VOutput distortion factor <4% with linear load, <6% with non-linear loadEfficiency 85% 87% 88%Crest factor 3:1 3:1 3:1Short circuit current (A) 25 29 29Overload cpability (online-mode) 110% sustained, 130% for 12s, >130% for 1.5s

BatteriesBackup times with 100% Load 50% Load 100% Load 50% Load 100% Load 50% Load

Standard 7 14 7 17 6 19Pulsar EXtreme C + 1 Pulsar EXB 23 47 27 60 23 80Pulsar EXtreme C + 2 Pulsar EXB 41 82 48 93 41 120Pulsar EXtreme C + 3 Pulsar EXB 53 125 65 136 62 168

Automatic battery test Yes, during freely programmable test intervals with no risk of a power supply interruption

Communication 1 RS232/U-Talk interference + communications-slotUSB Interface Yes Yes YesRS232 Interface Yes Yes YesOptional interface cards SNMP-10 BaseT card (Ethernet)

Status information cards

Environment conditionsNoise level <40 dBAEnvironment temperature 0 to 40°C

Conformity to standardsModel EN 50091-3/IEC 62040-3Safety EN 50091-1, EN 60950 (RD/), IEC 60950Electromagnetic compatability EN 50091-2/IEC 62040-2, EN 55022/B, FCC 47 Part 15 - Section B - Class A,

IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3Certification CE,TÜV/GS, UL, cUL, C-TickConstruction and manufacture ISO 9001

Dimensions (HxWxD in mm) and weights (in kg)UPS or EXB module Rack 88(2HU)x482.6x430 mm 88(2HU)x482.6x430 mm 88(2HU)x482.6x493 mmUPS Weight 10 (Tower) 14 (Rack) 12 (Tower) 16 (Rack) 15 (Tower) 20 (Rack)EXB Module Weight 11.5 (Tower) 17 (Rack) 15 (Tower) 21 (Rack) 21 (Tower) 27.5 (Rack)

Warranty

Connection for automaticdetection of external battery-module, EXB

PUL800018_E

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 180

Page 191: Shkaf Knurr Electronics e

by knürr

181

ELECTRONIC INTEGRATION

Pulsar EXtreme UPS / Online2000 / 3000 VA

Advanced communication- Unsurpassed communications

options- Solution-Pac UPS management

software- Parameters via

UPS driver software

User-friendly- Most straightforward

installation and integration- Convenient indication and con-

trol panel

Flexible and extendable- Hot-swap sockets- Backup times of

10 minutes to 8 hours- ECO Mode (up to 94% efficiency)

Unique - standard with Hot-SwapmoduleModular protection for sensitiveapplications, networks and tele-communications systems.

Reliable high-output technologies - Online double conversion

technology- 84-264 V Input voltage, without

battery use- CE/UL/TÜV-GS and ISO 14001

standards

Optimum availability- Hot-swap function, exchange

during running operation with-out interruption

- Automatic bypass- Redundancy

PUL80010_E

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 181

Page 192: Shkaf Knurr Electronics e

by knürr

182

ELECTRONIC INTEGRATION

Pulsar EXtreme UPS Installations

High output capabilityand reliability

Online double conversion technologyOnly this technology guarantees aconstant, clean output voltageand frequency. A sine-shapedoutput voltage is constantly gene-rated via the rectifier and inver-ter, regardless of disturbances inthe mains supply. The battery isonly required in the event of apower failure.

Wide input voltage range The wide input voltage reducesswitching and as a result, strainon the battery. Comet EXtremeoptimises the battery lifespanand calls on the battery onlywhen it is unavoidably necces-sary, that is, for example, in theevent of a power failure.

CE and UL certified

Highest possible availability

Hot-swap functionPulsar EXtreme enables UPSmaintenance, repair and swop-out, including battery changeduring running operation withoutinterrupting or causing distur-bance to the power supply.

Cold start via batteryThis function enables a problem-free start for your applications,even with a system failure.

Automatic bypassIn the event of an overload or adefect, Pulsar EXtreme C swit-ches the device without interrup-tion to the mains supply.

Advanced communications options

Pulsar EXtreme C provides anextensive package of communi-cations solutions for connectingelectronic data processing andmonitoring systems.

RS232 Serial interfaceEnables straightforward connec-tion of the UPS with a server, asan example, for:

Individual adaption of the PulsarEXtremeBy modifying the factory-setparameters (output voltage, battery test intervals, bypassoperation etc.) via the UPS driversoftware.

LAN and WAN management(SNMP/WEB) of the UPS and theconnected server via Solution-Pac.Solution-Pac enables the indivi-dual shutdown of your server inheterogeneous networks.

Solution-Pac softwareSolution-Pac provides the optionof:- Information for the user- Automatic shutdown of one or

more servers in a heterogenousnetwork.

- Remote monitoring and management of the UPS.

Additional communications slotEnables the integration of anadditional communication board(SNMP, telecommunicationsconnections etc.). UPS communi-cation becomes totally indepen-dent with these cards. For exam-ple, the user is informed aboutthe UPS status following a servershutdown.

7

6

Pulsar EXtreme UPS has been desi-gned to match the requirements ofthe most modern systems; networks, intranet and Internet ser-vers, active components, computersand telecommunications installati-ons, and medical and industrialapplications.

PUL80011_E6

PUL80012_E7

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 182

Page 193: Shkaf Knurr Electronics e

by knürr

183

ELECTRONIC INTEGRATION

Pulsar EXtreme UPS Installations

Flexible and extendable

Backup times from 10 minutesto several hoursPulsar EXtreme is standardequipped for at least 10 minutesbackup. Higher operating conti-nuity can be achieved with:- Up to 2 EXB battery extensions

that can be added during therunning operation.

Hot-swap, the flexible connection optionAs socket or fixed installationmodule, each with manual ins-pection bypass, enables theconnection or exchange of theUPS in just 1 minute.

Hot-swap socket module: Plug & Play- Mains supply cable with

DIN protective contact plug- 4 DIN protective contact plugs,

equipment sockets, additionalterminal for equipment.

4

User-friendly

Hot-swap for the most straight-forward installation and integration- 19” Model- Complete 19” mounting kit- Quick start instructions

Easy hot-swap module terminal- The Pulsar EXtreme 3000 rack

is supplied complete with sup-porting rails for 600-900 mmdepth cabinets

Indication and control elementsMalfunction indication- Overload- UPS Defect- Battery fault- Excess temperature › 40°C- % Battery backup- Indication of the degree of

capacity utilization in %- Operation via manual bypass- Operation in ECO mode- Operation in online mode- Battery operation- ON/OFF

2

1

PUL80013_E1

PUL80014_E2

PUL80015_E3

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 183

Page 194: Shkaf Knurr Electronics e

by knürr

184

ELECTRONIC INTEGRATION

Pulsar EXtreme Features

(1) Values with 50%, 66% and 100% loading

Nominal powerInput power rangeFrequency rangeInput power factor (THDI)Output voltageOutput harmonic contentEfficiency level Online modeECO modeCrest factorShort-circuit currentOverload capability

Standard backup time with 100% loadwith 50% load

EXB Battery extension module

Automatic battery test

Options for UPS or MultiSlot module

Noise levelEnvironmental temperature

ModelSecurityElectro-magnetic compatibility

CertificationsConstruction and manufacture

UPS, EXB DimensionsUPS WeightEXB Module LA Weight

Allgemeines

Environment

Conformity to standards

Dimensions (HxWxD in mm) and weights (in kg)

Warranty

2000VA/1330W 3000VA/2000W84 V/120 V/160 V to 265 V without battery support (1)

50/60 Hz0.99 (< 5%)

200 V/208 V/220 V/230 V/240 V<3% With linear load, <5% with non-linear load

89% 90%94% 94%3.1 3.127 41

130% for 60s, 160% for 10s, 250% for 1s

9 minutes 9 minutes20 minutes 20 minutes20 minutes 20 minutes36 minutes 36 minutes66 minutes 66 minutes

Yes, during freely programmable test intervals with no risk of a power supply interruption2/U-Talk Schnittstelle + Kommunikations-Slot

• SNMP 10 BaseT• 2 RS232 U-Talk or status information cards• RS232 or RS485 JBus/ModBus• Relay contacts (250 V, 2 A)• USB• 2 RS232/COM ports• 2 AS400 interfaces

45 dBA0 to 35°C

EN 50091-3EN 50091-1, IEC 60950

EN 50091-2, EN 55022/B, EN 55011/BIEC 61000-4, IEC 61000-3-2

CE,TÜV/GS, UL, cUL,ISO 9001, ISO 14001

177(4HU)x483x462 (Rack)31 (Rack) 38 (Rack)26 (Rack) 32 (Rack)41 (Rack) 54 (Rack)

2 Years

Pulsar EXtreme 2000 VA 3000 VA

Article numbersOrder no. UPS 06.100.630.1 06.100.631.1

Order no. EXB module LA 06.100.632.1 06.100.634.1

Order no. EXB modul XLA 06.100.633.1 06.100.635.1

Order no. SNMP card 06.100.636.1 06.100.636.1

Order no. relay card 06.100.637.1 06.100.637.1

General

Batteries

Communikation 1 RS 232 / U-Talk interface + communications slot

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 184

Page 195: Shkaf Knurr Electronics e

Strong Points and technical details Page 185Product Page 188

KVM Console Switches

KVM

by knürr

185

ELECTRONIC INTEGRATION

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 185

Page 196: Shkaf Knurr Electronics e

by knürr

186

ELECTRONIC INTEGRATION

DescriptionConsole switches are devices thatenable all servers in a companyto operate centrally from one orseveral workstations.This makes switches valuable foranyone who administers two ormore computers.The advantages of console swit-ches described here, which inclu-de low space requirement, lowprocurement and operating costsand high productivity, becomeeven more evident as more com-puters are connected, but alsoremain profitable with comparati-vely “small” 3-4 computer appli-cations, as the examples haveshown.Indeed, active switches should beimplemented to fully exploit allthe benefits that they have tooffer.

Selection criteria for console switchesGeneral- Can the system be intuitively

operated and does it have astandardised concept?

- Can the switches be operatedwith Hotkey from the remoteconsole?

- Are resolutions of 1600x1200pixels possible in daisy chainoperation?

- Can country-specific computersand keyboards be operated?

- Can original keyboards be usedat the consoles, and are allfunction keys active?

- Is a hotline and Internet operat-tor service available

Structure- Are equipment design forms

compact and suitable for 19inch systems?

- Is cabling expense low?- Are all models compatible and

can they daisy chain with oneanother?

Emulation- Is the mouse and keyboard

emulation fault tolerant withequipment failure?

- Can heterogeneous installationsbe operated with, for example,Sun, Compaq etc.?

- Is the system open to new com-puter systems? (Software update)

Console Switching Systems (KVM)Strong points

Can the system be expanded andintegrated?- Can equipment with serial ports

(VT100, ANSI) be integrated?- Are AutoScan and AutoSkip also

possible in complex installati-ons?

- Can more than four consoles beoperated?

- Can a mouse with 3 buttons andscroll function be connected?

- Can cascading or settling of theconsoles/computers be carriedout with UTP, fibre optics or IPover Internet?

Selection criteria for consoleswitches, system security- Can the software for emulation

and operating system be upgra-ded to the most up-to-date sta-tus with an update?

- Is the name of the selectedcomputer visible in clear text?

- Is access security available?- Are additional “vulnerable”

devices required for the admini-stration?

- Can the system be used formission-critical applications?

- Can the operating system of theswitches and the emulation beexchanged in the operation?(keyword: Flash technology)

- Can the mouse be reactivatedafter being plugged in?

- Is “hot connect” and “dis-connect” of the console swit-ches possible for restructuringduring operation?

- Can the emulation be perfor-med switch-independent?

Note:Please direct all enquiries to:[email protected]

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 186

Page 197: Shkaf Knurr Electronics e

by knürr

187

ELECTRONIC INTEGRATION

DimensionsH/W/D 44x424x123 mm (1 HU)H/W/D 89x424x123 mm (2 HU)

Weight4/8 Port model2.7 kg12/16 Port model3.6 kg

Power supply90-240 VAC, 60 W

ConnectionsCurrent: IEC 320Computer/Workstation: DB25 JackRS232: RJ45 6 Conductor

Video bandwidth250MHz

Video SyncHV, Composite, Sync-on-Green

EnclosureSteel, electro-galvanised, powder-coated (black)

IndicatorsBack-lit On/Off switch

LEDs1x LED for control displayDepending on the model, maximum 16 LEDs for indicatingselected computerDepending on the model, maximum 16 LEDs for indicatingactive computer

Environment temperature0-55°C

Relative air humidity5-80%

ApprovalsUL, cUL, TÜV, CE

Console Switching Systems (KVM)Technical data

Rear view of 16-port model

Rear view of 8-port model

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 187

Page 198: Shkaf Knurr Electronics e

by knürr

188

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = DepthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight

KVM Switches for PC Platforms & Multi-PlatformsW H D HU/U User & ports Model Order no. UP Price

1 1x4 PC 06.004.020.1 1 unit1 1x8 PC 06.004.021.1 1 unit2 1x12 PC 06.004.022.1 1 unit2 1x16 PC 06.004.023.1 1 unit1 1x4 MP 06.004.024.1 1 unit1 1x8 MP 06.004.025.1 1 unit2 1x12 MP 06.004.026.1 1 unit2 1x16 MP 06.004.027.1 1 unit

KVM - Console switchoverYou can administer up to 256 computersvia 1 workstation and 1 operator- Enables simultaneous access to up to 256

servers / PCs via 1 workstation- Available as optimum PC or multiple

multi-platform version - User-friendly on-screen menu- Extensive security features

Features overview:- Models for every requirement

B-Series with 4 and 8 portsC-Series with 4, 8 or 16 ports

- Straightforward cabling: Only one com-pact cable required for connecting eachcomputer and user workstation

- Maximum resolution: 1600x1280- Security package: User IDs, password

protection and profiles prevent unaut-horised access to the system andconnected computers

- Working made easy: Simply select therequired computer via the keyboard, theon-screen menu or the select keys onthe front of the equipment

- Pre-configuration: Installation can becarried out while operation is running

- Highly intelligent integration: The multi-platform version effortlessly brings PCs,UNIX systems, Apple and Sun under oneumbrella

- Expandable: Several UltraView PROunits can be inter-connected via a secure bus structure (connection of upto 256 computers)

- Flash upgradeable: With one straight-forward firmware upgrade, your systemremains at the most up-to-date status

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 188

Page 199: Shkaf Knurr Electronics e

by knürr

189

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = DepthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight

Connection Cable, KVM Switch for ComputerW H D L Keyboard Video Mouse Order no. UP Price

1.5 m PS/2/-AT PC VGA PS/2 - serial 06.004.201.9 1 unit3.0 m PS/2/-AT PC VGA PS/2 - serial 06.004.202.9 1 unit6.0 m PS/2/-AT PC VGA PS/2 - serial 06.004.203.9 1 unit

10.6 m PS/2/-AT PC VGA PS/2 - serial 06.004.204.9 1 unit15.2 m PS/2/-AT PC VGA PS/2 - serial 06.004.205.9 1 unit22.8 m PS/2/-AT PC VGA PS/2 - serial 06.004.206.9 1 unit30.4 m PS/2/-AT PC VGA PS/2 - serial 06.004.207.9 1 unit

1.5 m SUN KVM SUN 06.004.208.9 1 unit3.0 m SUN KVM SUN 06.004.209.9 1 unit6.0 m SUN KVM SUN 06.004.210.9 1 unit0.6 m SUN KVM SUN 06.004.211.9 1 unit

15.2 m SUN KVM SUN 06.004.212.9 1 unit22.8 m SUN KVM SUN 06.004.213.9 1 unit30.4 m SUN KVM SUN 06.004.214.9 1 unit

1.5 m SUN SUN SUN 06.004.215.9 1 unit3.0 m SUN SUN SUN 06.004.216.9 1 unit6.0 m SUN SUN SUN 06.004.217.9 1 unit

10.6 m SUN SUN SUN 06.004.218.9 1 unit15.2 m SUN SUN SUN 06.004.220.9 1 unit22.8 m SUN SUN SUN 06.004.221.9 1 unit30.4 m SUN SUN SUN 06.004.222.9 1 unit

Connection Cable, KVM Switch for Keyboard / Video / MouseW H D L Keyboard Video Mouse Order no. UP Price

1.5 m PS/2 PS/2 VGA PS/2 06.004.223.9 1 unit3.0 m PS/2 PS/2 VGA PS/2 06.004.224.9 1 unit6.0 m PS/2 PS/2 VGA PS/2 06.004.225.9 1 unit

10.6 m PS/2 PS/2 VGA PS/2 06.004.226.9 1 unit15.2 m PS/2 PS/2 VGA PS/2 06.004.227.9 1 unit22.8 m PS/2 PS/2 VGA PS/2 06.004.228.9 1 unit30.4 m PS/2 PS/2 VGA PS/2 06.004.229.9 1 unit

1.5 m SUN VGA SUN 06.004.230.9 1 unit3.0 m SUN VGA SUN 06.004.231.9 1 unit6.0 m SUN VGA SUN 06.004.232.9 1 unit

10.6 m SUN VGA SUN 06.004.233.9 1 unit15.2 m SUN VGA SUN 06.004.234.9 1 unit22.8 m SUN VGA SUN 06.004.235.9 1 unit30.4 m SUN VGA SUN 06.004.236.9 1 unit

1.5 m SUN SUN SUN 06.004.237.9 1 unit3.0 m SUN SUN SUN 06.004.238.9 1 unit6.0 m SUN SUN SUN 06.004.239.9 1 unit

10.6 m SUN SUN SUN 06.004.240.9 1 unit15.2 m SUN SUN SUN 06.004.241.9 1 unit22.8 m SUN SUN SUN 06.004.242.9 1 unit30.4 m SUN SUN SUN 06.004.243.9 1 unit

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 189

Page 200: Shkaf Knurr Electronics e

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 190

Page 201: Shkaf Knurr Electronics e

Strong Points and technical details Page 192Product Page 194

RMS System Monitoring

RMS

by knürr

191

ELECTRONIC INTEGRATION

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 191

Page 202: Shkaf Knurr Electronics e

by knürr

192

ELECTRONIC INTEGRATION

Until now system monitoringoptions were limited to activecomponents. Now, with SNMPmanagement systems, parame-ters like data emergence, errorrate, equipment configurationand, of course, downtime ofindividual connections or hard-ware components are all moni-tored. But the causes for suchdowntimes remain for the mostpart unclear, and are only firstrealised on-site, i.e. in the ser-ver or network rack or cabinet.Observance of the requiredenvironment parameters is,however, of enormous impor-tance for the fault-free opera-tion of high-grade components.Inadmissible fluctuations intemperature, humidity or powersupply are frequently the causeof hardware defects, thereforeconstant automatic monitoringis a fundemental requirementfor securing operational func-tionality. With the enclosuremonitoring systems availableon the market today, theseparameters and other factorscan be recorded, and can oftenbe passed directly on to asuperordinate managementsystem.

New System Monitoring Options (RMS)Strong points

However, recording of conditionsalone is often not enough to com-bat damage as the time fromoccurance of a critical conditionto initiation of combative measu-res, particularly with larger net-work envionments, is often quitelimited. In such cases it is extre-mely helpful if the monitoringsystem can automatically imple-ment constructive measures (e. g. additional active fans).When such incidents occur, theequipment should at least beable to immediately send a report(trap) to the managementsystem, which for example, willthen notify those responsible forthe network via e-mail or pager.This enables a sufficiently shortreaction time and a swift locationof the fault location and its sub-sequent elimination.With the option of connectingadditional sensors like smokedetectors, door contacts etc., notonly enclosures but entire roomsor building sections can be moni-tored. In this way all environ-mental parameters of a computercentre can be easily recorded andevaluated.

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 192

Page 203: Shkaf Knurr Electronics e

by knürr

193

ELECTRONIC INTEGRATION

The main tasks that a modernenclosure monitoring systemmust perform are to:-Guarantee a disturbance -freeoperation

- Provide early detection of fault-provoking influences

- Record all such incidents- Simplify service implementation

with automatic monitoring- Activate counteractive measu-

res in the event of malfunctio-ning

- Centrally control the conditionsof material in use (filters, filllevels, meter readings, inspec-tion intervals etc.).

Note:Please direct all enquiries to:[email protected]

System Monitoring Tasks (RMS)Technical data

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 193

Page 204: Shkaf Knurr Electronics e

by knürr

194

ELECTRONIC INTEGRATION

RMS COMPACT RMS MASTER UNIT RMS MASTER UNIT(DESKTOP VERSION) (1U 19” RACKMOUNT VERSION) (2U 19” RACKMOUNT VERSION)

PHYSICALDESCRIPTION & RMS COMPACT 19” RACK MOUNT VERSION (1U) 19” RACK MOUNT VERSION (2U)MOUNTINGARRANGEMENTSENCLOSURE STEEL CASE STEEL CASE STEEL CASE

WITH GREY EPOXY POWDER WITH GREY EPOXY POWDER WITH GREY EPOXY POWDERCOATING FINISH. COMPLIANT COATING FINISH. COMPLIANT COATING FINISH, COMPLIANT WITH CE EMI/RFI STANDARDS WITH CE EMI7RFI STANDARDS EMI7RFI STANDARDS WITH CE

DIMENSIONS (MM) DEPTH 200, WIDTH 155, DEPTH 265, WIDTH 427, DEPTH 265, WIDTH 427, HEIGHT 86HEIGHT 30 HEIGHT 44 WEIGHT 2.06 KG

POWER SUPPLY EXTERNAL PSU INTERNAL MAINS PSU INTERNAL MAINS PSU 230 VAC / 13W REQUIRING 85-264VAC, REQUIRING 85-- 48 VDC OPTION 47-440HZ 15W, 48VDC OPTION 264VAC, 47-440HZ 15W.

48VDC OPTIONRS232 PORTS 1 RS232 PORTS: 2 RS232 PORTS: 2 RS232 PORTS.

PORT 1 PORT 1 FOR MODEM USE, PORT 1 FOR MODEM USE,FOR PASS THROUGH PORT 2 FOR PASS THROUGH PORT 2 FOR PASS THROUGH TO COMMS TO COMMS TO COMMS

DEVICE DEVICE DEVICEDIGITAL INPUTS UP TO 7 INPUTS SUITABLE 16 INPUTS SUITABLE 32 INPUTS SUITABLE

TO DETECT A VOLT FREE TO DETECT A VOLT FREE TO DETECT A VOLTDRY CONTACT DRY CONTACT FREE DRY CONTACT

TECHNICALDIGITAL OUTPUTS UP TO 3 8 GALVANICALLY ISOLATED 16 GALVANICALLY ISOLATED

RELAYS WITH RELAYS WITHNORMALLY OPEN, NORMALLY NORMALLY OPEN, NORMALLY CLOSED AND COMMON CLOSED AND COMMON CONTACTS. EACH RELAY CAN BE CONTACTS. EACH RELAY CAN BEREMOTELY TRIGGERED VIA REMOTELY TRIGGERED VIA THE NETWORK OR TRIGGERED THE NETWORK OR TRIGGERED BY AN INPUT CHANNEL OR BY AN INPUT CHANNEL ORCOMBINATION OF INPUT COMBINATION OF INPUT CHANNELS USING CHANNELS USING

BOOLEAN LOGIC BOOLEAN LOGICANALOGUE INPUTS 4 ANALOGUE INPUTS FOR 4 ANALOGUE INPUTS FOR

1 TEMPERATURE/ TEMPERATURE / TEMPERATURE /HUMIDITY SENSOR HUMIDITY SENSOR HUMIDITY SENSOR

POWER N / A N / A N / ARECEPTACLECONTROLRS-485 BUS A RANGE OF OPTIONAL A RANGE OF OPTIONAL

MODULES CAN BE ADDED TO MODULES CAN BE ADDED TO THE MASTER DEVICE USING THE MASTER DEVICE USING THE MEA BUS THE MEA BUS

ADDITIONAL SNMP MONITORING / SNMP MONITORING / SNMP MONITORING / MANAGEMENT* MANAGEMENT* MANAGEMENT*WEB MONITORING / WEB MONITORING / WEB MONITORING / MANAGEMENT* MANAGEMENT* MANAGEMENT*JAVA VIEWING APPLET* JAVA VIEWING APPLET* JAVA VIEWING APPLET*JAVA REMOTE VIEWING APPLET* JAVA REMOTE VIEWING APPLET* JAVA REMOTE VIEWING APPLET*

DIAL-OUT ON ALARMS DIAL-OUT ON ALARMSDIAL-IN ACCESS DIAL-IN ACCESS

TERMINAL CONFIGURATION TERMINAL CONFIGURATION TERMINAL CONFIGURATIONBOOLEAN LOGIC OUTPUT BOOLEAN LOGIC OUTPUT BOOLEAN LOGIC OUTPUT CONTROL CONTROL CONTROL

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 194

Page 205: Shkaf Knurr Electronics e

by knürr

195

ELECTRONIC INTEGRATION

RMS COMPACT RMS MASTER UNIT RMS MASTER UNIT(DESKTOP VERSION) (1U 19” RACKMOUNT VERSION) (2U 19” RACKMOUNT VERSION)

OPTIONALSNMP / WEB MODULE SNMP MONITORING / SNMP MONITORING/ SNMP MONITORING/

MANAGEMENT MANAGEMENT MANAGEMENTWEB MONITORING MANAGEMENT WEB MONITORING MANAGEMENT WEB MONITORING MANAGEMENTMIB PROVIDED IN DOS MEA MIB PROVIDED IN DOS MEA MIB PROVIDED IN DOS AND TAR FORMAT AND TAR FORMAT AND TAR FORMAT

RS232 INTERFACE TO CONNECT TO BASE UNIT

RS232 INTERFACE TO CONNECT ANALOGUE INPUT FOR RS232 INTERFACE TO TO BASE UNIT OPTIONAL T/H SENSOR UNIT CONNECT TO BASE UNITANALOGUE INPUT FOR ANALOGUE INPUT FOR OPTIONAL T/H SENSOR OPTIONAL T/H SENSOR

ANALOGUE INPUTS NIL NIL (UP TO 16 AVAILABLE) NIL (UP TO 16 AVAILABLE)ANALOGUE OUTPUTS NIL NIL (UP TO 16 AVAILABLE) NIL (UP TO 16 AVAILABLE)POWER NIL 2 POWER INPUTS 2 POWER INPUTS EXPANSION 4 POWER OUTPUTS (2x2) 4 POWER OUTPUTS (2x2)MODULE 1 RS 485 CONNECTOR FOR 1 RS 485 CONNECTOR FOR

MEA BUS (IN/Out) MEA BUS (IN/Out)DIGITAL/ANALOGUE 1 POWER INPUT 1 POWER INPUTMODULE 8 RELAY CONTACT OUTPUTS 8 RELAY CONTACT OUTPUTS

8 DIGITAL INPUTS 8 DIGITAL INPUTS (PULLED UP TO + 5V OR +12V) (PULLED UP TO + 5V OR +12V)4 ANALOGUE INPUTS FOR 4 ANALOGUE INPUTS FOR TEMP / HUMIDITY TEMP / HUMIDITYSENSOR SENSOR2 ANALOGUE OUTPUTS 2 ANALOGUE OUTPUTS1 RS485 CONNECTOR FOR 1 RS485 CONNECTOR FOR MEA BUS (IN/OUT) MEA BUS (IN/OUT)

Order-Number 06.108.031.1 06.108.002.1 06.108.003.1

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 195

Page 206: Shkaf Knurr Electronics e

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 196

Page 207: Shkaf Knurr Electronics e

Product Page 198

TFT Keyboards, Displays

TFT

by knürr

197

ELECTRONIC INTEGRATION

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 197

Page 208: Shkaf Knurr Electronics e

by knürr

198

ELECTRONIC INTEGRATION

19” Compact KeyboardIBM Compatible keyboard with trackballW H S HU/U A1 A2 Pmax Model Order no. UP Price

German 06.002.048.3 1 unit

VHP00155_E

- Thin keyboard with 84 keys andintegrated trackball

Electrical data- Voltage supply

+ 5 V/DC max. 18 mA- Connection cable (1.6 m) with tapping

for two 6-pole MiniDIN plugs(PS/2)- For Windows 98/ME/NT/2000/XP

DimensionsLength x width x height370 x 138.5 x 20 mm

19” Compact KeyboardThin, IBM compatible keyboard with integrated touch padW H S HU/U A1 A2 Pmax Model Order no. UP Price

German 06.002.177.3 1 unit

VHP00203_E

- Model with 105 keys- Integrated mouse function

Electrical data- Voltage supply

+ 5 V/DC maximum 18 mA- Connection cable: (1.8 m)

Round cable length:with tapping for two 6-pole MiniDINplugs(PS/2)

- For Windows 98/ME/NT/2000/XP

DimensionsLength x width x height415 x 193 x 35.5 mm

Note:Country-specific models availableon request

Compact KeyboardW H S HU/U A1 A2 Pmax Model Order no. UP Price

German 6.002.165.3 1 unit

- Thin compact keyboard with 86 keys for AT,PS/2 systems

- Low space requirement and weight- Ideal for carry systems and 19” systems- Highly reliable with “gold crosspoint

contacts”- For Windows 98/ME/NT/2000/XP

Electrical data- Voltage supply

+ 3.3-5 V/DCmaximum 10 mA

- Connection cable (1.7 m)MiniDIN plug (PS/2)

DimensionsLength x width x height281.5 x 131.5 x 24 mm

VHP00157_E

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 198

Page 209: Shkaf Knurr Electronics e

by knürr

199

ELECTRONIC INTEGRATION

19” Compact Keyboard, IP 65W H S HU/U A1 A2 Pmax Model Order no. UP Price

German 06.002.042.3 1 unit

VHP00154_E

VHP00156_E

- 19” Compact keyboard with long hub in IP 65

- Low space requirement with compactdesign

Electrical data- Voltage supply + 5 V/DC

maximum 30 mA- Spiral connection cable with 5-pole

DIN plug

DimensionsLength x width x height405 x 185 x 36.5 mm (without keys)

19” KeyboardW H S HU/U A1 A2 Pmax Model Order no. UP Price

German 6.002.170.3 1 unit

- 19” Compact keyboard- Keys with “Gold crosspoint contacts”

Electrical data- Voltage supply + 5 V/DC 200 mA- Spiral connection cable (2 m)

6-pole Mini DIN plug- For Windows 98/ME/NT/2000/XP

DimensionsLength x width x height405 x 185 x 36.5 mm (without keys)

Note:Country-specific models availableon request

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 199

Page 210: Shkaf Knurr Electronics e

by knürr

200

ELECTRONIC INTEGRATION

Dimensions in mm: W = Width, H = Height, D = DepthHU / U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight

15” TFT DisplayIn 1 HU keyboard drawerW H D HU/U kg Model Order no. UP Price483 600 1 10 with trackball PS/2 06.100.263.1 1 unit

suitable for keyboard with trackball PS/2, Ger. 06.002.048.3 1 unitsuitable for keyboard with trackball PS/2, US. 06.002.047.3 1 unit

- For installation in 19” enclosures- Only 1 HU- Designed for trackball keyboard- Acrylic screen- Wide reading angle- Integrated VGA analogue/digital converter- For installation in enclosures,

depth 800 or 900 mm

Finish- Front panel, powder-coated,

RAL 7035 light-grey, textured- Enclosure, powder-coated,

RAL 7035 light-grey, textured- Control handle, powder-coated,

RAL 7035 light-grey, textured

Dimensions- Height 1 HU- Width 19” = 483 mm- Depth 600 mm

Power supply- External wide range power supply

90-250 VAC, 50/60 Hz

Power consumption, max. 30 W

Settings - Brightness, contrast- RGB Colour- Horizontal/vertical position- Clock- Phase- OSC Language

WeightApprox. 10 kg

Display- Diagonal 15.1”- Visible screen

surface 304.1x228.1 mm- Brightness 200 cd/m2- Lighting

MTBF 50 000 h- Geometric

distortion <0.3 mm- Max. 256 000 colours- Pitch 0.099x0.297 mm

Screen- Acrylic- Antireflex

Video input- VerA (RGB analogue, Sync TTL)- Connections

HD D Sub 15-pole VGA

Sync input- Composite sync

Horizontal scan frequency- 50-100 Hz

Vertical scan frequency- 50-100 Hz

Band width- 140 MHz (-3dB)

Resolution- 1024x768 pixel- 800x600/640x480 centric resolution

using the corresponding number ofpixels (original) or expanded (zoomingfunction)

Temperature range- Operation 0-40°C- Storage (not compressed) -25-60°C

Supply scheduleKeyboard drawer with integrated display1 Set of telescopic slides1 Power supply1 Connection cable1 User handbook

Further displays available on request!

VHP00248_E

VHP00246_E

113-200_eng_final.qxd 07.08.2002 15:31 Uhr Seite 200

Page 211: Shkaf Knurr Electronics e

Strong Points Page 202Product Page 203

di-strip Socket Strips

di-strip

by knürr

201

POWER SUPPLY SYSTEMS

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 201

Page 212: Shkaf Knurr Electronics e

by knürr

202

di-stripStrong points

Robust Protects the plug field with raisedenclosure edges

StabilityHigh stability and distortion resistance with closed sheet steelenclosures

Full power With all connected equipmentdue to continuous brass busbarsContact safety and low contactresistance with double springcontacts

Optimal space utilization With 19" installation - Due to low height, 1 HU

(44.45 mm)- Due to 45° positioning of

sockets

Internationally compatible

Appealing design With profiled enclosures, designside panels in visible areas

6

5

4

3

2

1

DOS00291_E1

DOS00312_E2

DOS317_E3

DOS00365_E4

DOS00721_E5

DOS00366_E6

POWER SUPPLY SYSTEMS

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 202

Page 213: Shkaf Knurr Electronics e

by knürr

203

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip ClassicStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Order no. UP Price1783 17 03.300.067.x 1 unit1383 13 03.300.063.x 1 unit

983 9 03.300.059.x 1 unit583 5 03.300.055.x 1 unit

1733 16 with switch 03.302.066.x 1 unit1333 12 with switch 03.302.062.x 1 unit

933 8 with switch 03.302.058.x 1 unit533 4 with switch 03.302.054.x 1 unit

- Optionally with back-lit switch,2-pole switching

- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket distance: 100 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWGVDE Certificate

Colour combinationFinal digit of order number .1:RAL 7035 light-greyFinal digit of order number .6:Enclosure RAL 2003 pastel orangePlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets

DOS00403_E

DOS00260_E With switch

Without switchDOS00261_E

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 203

Page 214: Shkaf Knurr Electronics e

by knürr

204

POWER SUPPLY SYSTEMS

DOS20021_E With switch

With switch

With switch

Without switch

Without switch

Di-Strip CompactStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Order no. UP Price883 15 03.300.015.x 1 unit732 11 03.300.111.x 1 unit683 11 03.300.011.x 1 unit532 7 03.301.107.x 1 unit532 7 03.300.107.x 1 unit483 7 03.300.007.x 1 unit382 4 03.301.104.x 1 unit382 4 03.300.104.x 1 unit333 4 03.300.004.x 1 unit883 14 with switch 03.302.014.x 1 unit732 10 with switch 03.302.110.x 1 unit683 10 with switch 03.302.010.x 1 unit532 6 with switch 03.303.106.x 1 unit532 6 with switch 03.302.106.x 1 unit483 6 with switch 03.302.006.x 1 unit382 3 with switch 03.303.103.x 1 unit382 3 with switch 03.302.103.x 1 unit333 3 with switch 03.302.003.x 1 unit

- Optional with back-lit switch,2-pole switching

- 19’’ Installation option (with length 483 mm)- 2 Models: standard side panel or design side

panel- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWGVDE Certificate

Colour combinationFinal digit of order number .1:RAL 7035 light-greyFinal digit of order number .6:Enclosure RAL 2003 pastel orangePlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19” Mounting brackets (additional with 19” installation option)

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

DOS00401_E

DOS00263_E

DOS20020_E

DOS00262_E

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 204

Page 215: Shkaf Knurr Electronics e

by knürr

205

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

DOS00692_E

Di-Strip Protector LSStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Order no. UP Price883 13 03.308.013.1 1 unit683 9 03.308.009.1 1 unit483 5 03.308.005.1 1 unit

Protector circuit breaker- Circuit breaker for overload and short-

circuit- Protects cables and feeds with rapid

switching off and defined delayed cutoffwith overload

- Circuit breaker: 16 A- Tripping characteristic,

type B, 2-pole- 19’’ Installation option

(with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 78 mmEnclosure width: 44.4 mm (= 1 HU)Cable 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWGVDE Certificate

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19” Mounting brackets (additional with 19” installation option)

Di-Strip Protector, FIStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Order no. UP Price883 13 03.304.013.1 1 unit683 9 03.304.009.1 1 unit483 5 03.304.005.1 1 unit

Protector, fault current circuit breakerRCCB for user protection- Prevents electricity and fire accidents

with safe and rapid switching off- Activates with fault current occurence,

e.g. with accidental touching of mainsvoltage-carrying components with defective insulation

- Residual operating current I = 10 mAfor alternating and intermittent faultdirect current

- Reaction time 10 - 30 ms- 19’’ Installation option

(with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbar,brassCable: PVCDimensions

Socket distance: 50 mmHeight: 78 mmEnclosure width: 44.4 mm (= 1 HU)Cable 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19” Mounting brackets (additional with 19” installation option)

DOS20065_E With fault current circuit breaker

With fault current circuit breaker

with circuit breaker

DOS00264_E with circuit breaker

DOS00264_E

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 205

Page 216: Shkaf Knurr Electronics e

by knürr

206

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Protector FI / LSStandard DIN 49 440 (VDE)L S n F1 F2 19“ safe Model Order no. UP Price883 13 03.310.013.1 1 unit683 9 03.310.009.1 1 unit483 5 03.310.005.1 1 unit

Protector FI / LS- RCCB and circuit breaker- Provides a combination of user, overload

and short-circuit protection - Residual operating current I = 30 mA

for alternating and pulsating direct faultcurrent

- Circuit breaker 16 A- Tripping characteristic

type B, 2-pole- 19’’ Installation option

(with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbars,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 78 mmEnclosure width: 44.4 mm (= 1 HU)Cable 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19” Mounting brackets (additional with 19” installation option)

DOS00693_E

DOS00264_E

DOS20059_E

DOS00486_E

Di-Strip Protector Emergency OFFStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Order no. UP Price

683 10 Compact 03.326.010.1 1 unit483 8 Compact 03.326.006.1 1 unit

1333 12 Classic 03.326.062.1 1 unit933 8 Classic 03.326.058.1 1 unit

- With 2-pole emergency OFF switch for userprotection

- For protecting operating staff- For manual emergency switch-off of the

connected equipment - Phase and neutral area safely separated- Switch must be specifically unlatched for

restart - 19’’ Installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: Classic, 100 mm;Compact, 50 mmHeight: 101 mmEnclosure width: 44.4 mm (= 1 HU)Cable 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19” Mounting brackets (additionalwith 19” installation option)

Classic with emergency OFF switch

DOS00487_E Protector with emergency OFF switch

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 206

Page 217: Shkaf Knurr Electronics e

by knürr

207

POWER SUPPLY SYSTEMS

DOS00456_E

DOS00488_E

DOS20061_E

DOS00266_E

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Protector Emergency Stop FI / LSStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Order no. UP Price683 8 03.328.008.1 1 unit

- With 2-pole emergency OFF switch for userprotection

- For protecting operating staff- For manual emergency switch-off of the

connected equipment - Phase and neutral area safely separated- Switch must be specifically unlatched for

restart- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: Compact, 50 mmHeight: 101 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

AdditionalWith 2-pole fault current and circuit breaker, provides a combination of user,overload and short-circuit protection

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets

Di-Strip Power CleanerStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Order no. UP Price883 13 03.312.013.x 1 unit683 9 03.312.009.x 1 unit483 5 03.312.005.x 1 unit

- With integrated mains filter- The integrated mains filter prevents,

- high-frequency disturbances from themains affecting electronic equipment.

- the transmission of disturbances from theequipment to the mains.

- The mains filter meets the requirements ofVDE 0565-3 and EN 133200.

- 19’’ Installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbar, brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 101 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyEnclosure RAL 2003 pastel orangePlastic parts: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19” Mounting brackets (additional with 19” installation option)

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 207

Page 218: Shkaf Knurr Electronics e

by knürr

208

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Safety BasicStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Order no. UP Price732 10 03.316.110.x 1 unit683 10 03.316.010.x 1 unit532 6 03.317.106.x 1 unit532 6 03.316.106.x 1 unit483 6 03.316.006.x 1 unit432 4 03.317.104.x 1 unit432 4 03.316.104.x 1 unit383 4 03.316.004.x 1 unit

- With overvoltage protection- A combination of varistors and gas dis-

charge arresters guarantee a rapid respon-se and a high discharge capacity

- Simple but effective protection against in-direct strikes and voltage spikes from themains

- Double protection:- 1. Up to maximum surge current resi-

stance, transient overvoltages are loweredto harmless values

- 2. If the surge current resistance is excee-ded the connected equipment is separatedfrom the mains as protection against fur-ther overvoltage spikes (green functiondisplay goes off). For further use, the pro-tection module can then be exchanged.For increasing the protection function, acoarse filter should be installed in advancein the building installation.

- 19’’ Installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94V0), recycleableInner conductor: continuous busbars,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyFinal digit of order number . 6:Enclosure RAL 2003 pastel orangePlastic components: RAL 7035 light-grey

Technical dataMains voltage 230 VAC +/- 10 %Nominal current 16 AFeature class: D (refined protection inaccordance with DIN VDE 0675)Surge current resistance (8/20 µs wave):maximum 10 kAProtection level (1.5/50 µs wave): ‹ 1200 V(L/N against PE)

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS00306_E

DOS20068_E

DOS00270_E

With overvoltageprotection

With overvoltageprotection

With overvoltage protection

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 208

Page 219: Shkaf Knurr Electronics e

by knürr

209

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Safety StandardStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Order no. UP Price883 13 03.318.013.x 1 unit732 9 03.319.109.x 1 unit732 9 03.318.109.x 1 unit683 9 03.318.009.x 1 unit532 5 03.319.105.x 1 unit532 5 03.318.105.x 1 unit483 5 03.318.005.x 1 unit

- With overvoltage protection- With integrated mains filter- With back-lit switch, 2-pole switching- A combination of varistors and gas

discharge arresters guarantee a rapidresponse and a high discharge capacity

- Simple but effective protection against in-direct strikes and voltage spikes from themains and high-frequency disturbance signals

- Overvoltage protection:- 1. Up to maximum surge current resistance,

transient overvoltages are lowered to harm-less values - 2. If the surge current resistance is excee-

ded the connected equipment is separatedfrom the mains as protection against furt-her overvoltage spikes (green function dis-play goes off). For further use, the protec-tion module can then be exchanged.For increasing the protection function, acoarse filter should be installed in advancein the building installation.

- Mains filter:- High-frequency disturbance signals are

effectively eliminated with the high-stopmains filter

- 19’’ Installation option(with length 483 mm)

- Socket rotation: 45°- Cable: HO5VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94V0), recycleableInner conductor: continuous busbars,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyFinal digit of order number . 6:Enclosure RAL 2003 pastel orangePlastic components: RAL 7035 light-grey

Technical dataMains voltage 230 VAC +/- 10 %Nominal current 16 AFeature class: D (refined protection inaccordance with DIN VDE 0675)Surge current resistance (8/20 µs wave):maximum 10 kAProtection level (1.5/50 µs wave): ‹ 1200 V(L/N against PE)Mains filter (low pass): attenuation with 1MHz, › 45 dB

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS20069_E

DOS00307_E

DOS00271_E

With overvoltage protectionand mains filter

With overvoltage protectionand mains filter

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 209

Page 220: Shkaf Knurr Electronics e

by knürr

210

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Master-SlaveStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Order no. UP Price683 9 03.314.009.1 1 unit483 5 03.314.005.1 1 unit

- If the master equipment is switched, theslave sockets are also switched (together,with short delay to the master).Consequently, convenient On-Off switchingof several difficult to access devices.Switching thresholds can be set from out-side via the potentiometer

- Note:- Power consumption of the master equip-

ment must be constantly over the swit-ching on threshold. When switching off themaster equipment, the power consump-tion must fall below the switching offthreshold.

- 19’’ Installation option(with length 483 mm)

- Socket rotation: 45°- Cable H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbars,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Technical dataThreshold setting rangeOn: 20 mA - 200mA (supply status, ca. 55 mA)Off: 16 mA - 160mA (supply status, ca. 44 mA)Switching delay 550 ms +/- 20%Electronic module, 2-pole switching

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS20070_E

DOS00268_E

With master-slave module

With master-slave module

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 210

Page 221: Shkaf Knurr Electronics e

by knürr

211

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip CombiStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Order no. UP Price782 9 03.320.109.1 1 unit733 9 03.320.009.1 1 unit582 5 03.321.105.1 1 unit582 5 03.320.105.1 1 unit533 5 03.320.005.1 1 unit

- Master-slave with overvoltage protectionand mains filter

- Automatic switching of equipment with integrated overvoltage protection and mains filter

- Joint functions of the master-slave (page 210) and the safety standard (page 209)

- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbars,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Technical dataOvervoltage protection and mains filterMains voltage: 230 VAC +/- 10 %Nominal current: 16 AFeature class: D (refined protection inaccordance with DIN VDE 0675)Surge current resistance (8/20 µs wave):maximum 10 kAProtection level (1,5/50 µs wave): ‹ 1500 V (L + N against PE)Mains filter (low pass): attenuation with 1MHz, › 45 dBMaster-slave functionThreshold setting rangeOn: 20 mA - 200 mA (supply status, ca. 55 mA )Off: 16 mA - 160 mA (supply status, ca. 44 mA )Switching delay 550 ms +/- 20 %Electronic module, 2-pole switching

Supply schedule1 Socket strip2 Mounting brackets

DOS00273_E

DOS00325_E

DOS00272_E

With master-slave overvoltage protection and

mains filter

With master-slave overvoltage protection and

mains filter

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 211

Page 222: Shkaf Knurr Electronics e

by knürr

212

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip GST18 Plug System (Wieland) CompactStandard DIN 49 440 (VDE)L S n F1 F2 19“ Safe Model Oder no. UP Price583 6 with switch 03.302.206.1 1 unit422 3 with switch 03.302.203.1 1 unit533 7 03.300.207.1 1 unit383 4 03.300.204.1 1 unit

- Quick and efficient plug connection system- Plug-in electro-installation in place of con-

ventional wiring- Speed:

- Due to straightforward plugging togetherof pre-configured elements

- Flexibility:- Due to the cable (cable length)

- Efficient:- Convenient exchange of socket strips, with

no cabling expense- Safety:

- Due to plug systems, all faulty installati-ons are excluded

- Space-saving:- Use of protection and switching functions

can be extended to additional socket stripswith no loss of plugging space by exten-ding cabling (maximum load rating 16A)

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94V0), recycleableInner conductor: continuous busbars,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/10 A

Supply schedule1 Socket strip2 Mounting brackets

DOS20060_E

DOS00663_E

DOS20045_E

DOS20046_E

Di-Strip Safety BasicWith GST18 plug systemL S n F1 F2 19“ Safe Model Order no. UP Price433 03.316.204.1 1 unit

- With overvoltage protection- Technical description, see page 208

Di-Strip Safety StandardWith GST18 plug systemL S n F1 F2 19“ Safe Model Order no. UP Price583 03.318.205.1 1 unit

- With overvoltage protection, with integratedmains filter and back-lit switch

- Technical description, see page 209

Di-Strip Master SlaveWith GST18 plug systemL S n F1 F2 19“ Safe Model Order no. UP Price533 03.314.205.1 1 unit

- Technical description, see page 210

With switch

Without switch

DOS20072_E

DOS20073_E

DOS00464_E

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 212

Page 223: Shkaf Knurr Electronics e

by knürr

213

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

DOS00467_E

DOS00469_E

DOS00471_E

DOS00470_E

Power Supply LineAccessories for GST 18 plug systemL S n F1 F2 19“ Safe Model Order no. UP Price2000 04.000.040.0 1 unit5000 04.000.041.0 1 unit

- Mains plug CEE/VII - GST 18 socket(Wieland)

- Line, H05VV-F3G 1.5 mm2

ColourWhite

Connection LineAccessories for GST 18 plug systemL S n F1 F2 19“ Safe Model Order no. UP Price1000 04.000.044.0 1 unit3000 04.000.045.0 1 unit

- GST 18 plug - GST 18 socket- Line, H05VV-F3G 1.5 mm2

ColourWhite

GST18 Socket PartL S n F1 F2 19“ Safe Model Order no. UP Price

04.000.046.0 1 unit

- With screw terminal for cross-section, 1.5-2.5 mm2 with cable strain relief

- For individual, customer-side connection

ColourWhite

GST18 Plug PartL S n F1 F2 19“ Safe Model Order no. UP Price

04.000.047.0 1 unit

- With screw terminal for cross-section, 1.5-2.5 mm2 with cable strain relief

- For individual, customer-side additionalcabling

ColourWhite

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 213

Page 224: Shkaf Knurr Electronics e

by knürr

214

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip CompactStandard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price883 15 03.400.015.x 1 unit732 11 03.400.111.x 1 unit683 11 03.400.011.x 1 unit532 7 03.400.107.x 1 unit483 7 03.400.007.x 1 unit382 4 04.400.104.x 1 unit333 4 04.400.004.x 1 unit883 14 with switch 03.402.014.x 1 unit732 10 with switch 03.402.110.x 1 unit683 10 with switch 03.402.010.x 1 unit532 6 with switch 03.402.106.x 1 unit483 6 with switch 03.402.006.x 1 unit382 3 with switch 03.402.103.x 1 unit333 3 with switch 03.402.003.x 1 unit

- Optional with back-lit switch,2-pole switching

- 19’’ Installation option (with length 483 mm)- 2 Models: standard side panel or design side

panel- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: full busbar, brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyFinal digit of order number .6:Enclosure, RAL 2003 pastel orangePlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

Di-Strip ClassicStandard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price1783 17 03.400.067.x 1 unit1383 13 03.400.063.x 1 unit

983 9 03.400.059.x 1 unit583 5 03.400.055.x 1 unit

1733 16 with switch 03.402.066.x 1 unit1333 12 with switch 03.402.062.x 1 unit

933 8 with switch 03.402.058.x 1 unit533 4 with switch 03.402.054.x 1 unit

- Optional with back-lit switch,2-pole switching

- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 100 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyFinal digit of order number .6:Enclosure, RAL 2003 pastel orangePlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets

DOS00260_F_E

DOS00261_F_E

DOS20021_F_E

DOS00262_F_E

DOS00263_F_E

DOS20020_F_E

With switch

With switch

Without switch

Without switch

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 214

Page 225: Shkaf Knurr Electronics e

by knürr

215

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Protector FI Standard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price883 13 03.404.013.1 1 unit683 9 03.404.009.1 1 unit483 5 03.404.005.1 1 unit

Protector, fault current circuit breakerRCCB for user protection- Prevents electricity and fire accidents

with safe and rapid switching off- Activates with fault current occurence,

e.g. with accidental touching of mainsvoltage-carrying components withdefective insulation

- Residual operating current I = 10 mAfor alternating and pulsating direct faultcurrent

- Reaction time 10 - 30 ms- 19’’ Installation option (with length 483

mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 78 mmEnclosure width: 44.4 mm (= 1 HU)Cable 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

Di-Strip Protector LSStandard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price883 13 03.408.013.1 1 unit683 9 03.408.009.1 1 unit483 5 03.408.005.1 1 unit

Protector circuit breaker- Circuit breaker for overload and short-

circuit- Protects cables and feeds with rapid

switching off and defined delayed cutoffwith overload

- Circuit breaker: 16 A- Tripping characteristic, type B, 2-pole- 19’’ Installation option

(with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 78 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS20057_E

DOS20026_E

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 215

Page 226: Shkaf Knurr Electronics e

by knürr

216

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Protector FI / LSStandard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price883 13 03.410.013.1 1 unit683 9 03.410.009.1 1 unit483 5 03.410.005.1 1 unit

Protector FI / LS- Fault current and circuit breaker- Provides a combination of user, overload

and short-circuit protection - Residual operating current I = 30 mA

for alternating and pulsating fault directcurrent

- Circuit breaker 16 A- Tripping characteristic

type B, 2-pole- 19’’ Installation option

(with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 78 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

Di-Strip Protector Emergency OFFStandard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price

683 10 Compact 03.426.010.1 1 unit483 6 Compact 03.426.006.1 1 unit

1333 12 Classic 03.426.062.1 1 unit933 8 Classic 03.426.058.1 1 unit

- With 2-pole emergency OFF switch for userprotection

- For protecting operating staff- For manual emergency switch-off of the

connected equipment - Phase and neutral area safely separated- Switch must be specifically unlatched for

restart - 19” Installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: Classic, 100 mm;Compact 50mmHeight: 101 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS 20026_E

DOS20027_E

DOS20028_E

Classic with emergency Off

switch

Compact withemergency Off

switch

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 216

Page 227: Shkaf Knurr Electronics e

by knürr

217

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Protector Emergency Off, FI / LSStandard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price683 8 03.428.008.1 1 unit

- With 2-pole emergency OFF switch for userprotection

- For protecting operating staff- For manual emergency switch-off of the

connected equipment - Phase and neutral area safely separated- Switch must be specifically unlatched for

restart - Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: Compact, 50 mmHeight: 101 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Additional:With 2-pole fault current circuit breakerand circuit breakerProvides a combination of user, overloadand short-circuit protection.

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets

Di-Strip Power CleanerStandard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price883 13 03.412.013.x 1 unit683 9 03.412.009.x 1 unit483 5 03.412.005.x 1 unit

- With integrated mains filter- The integrated mains filter prevents,

- high-frequency disturbances from themains affecting electronic equipment.

- the transmission of disturbances from theequipment to the mains.

- The mains filter meets the requirements ofVDE 0565-3 and EN 133200.

- 19’’ Installation option (with length 483mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyFinal digit of order number .6:Enclosure, RAL 2003 pastel orangePlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS20029_E

DOS20030_E

With emergency Off switchand FI / LS circuit breaker

with mains filter

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 217

Page 228: Shkaf Knurr Electronics e

by knürr

218

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Safety BasicStandard CDD 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price732 10 03.416.110.x 1 unit683 10 03.416.010.x 1 unit532 6 03.416.106.x 1 unit483 6 03.416.006.x 1 unit432 4 03.416.104.x 1 unit383 4 03.416.004.x 1 unit

- With overvoltage protection- A combination of varistors and gas

discharge arresters guarantee a rapid res-ponse and a high discharge capacity

- Simple but effective protection againstindirect strikes and interfering pulses fromthe mains

- Double protection:- 1. Up to maximum surge current resi-

stance, transient overvoltages are lowe-red to harmless values

- 2. If the surge current resistance isexceeded the connected equipment isseparated from the mains as protectionagainst further overvoltage spikes (greenfunction display goes off). For furtheruse, the protection module can then beexchanged.For increasing the protection function, acoarse filter should should be installed inadvance in the building installation.

- 19’’ Installation option (with length 483mm)

- 2 Models: standard side panel or designside panel

- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyFinal digit of order number .6:Enclosure, RAL 2003 pastel orangePlastic components: RAL 7035 light-grey

Technical dataMains voltage 230 VAC +/- 10 %Nominal current 16 AFeature class: D (refined protection inaccordance with DIN VDE 0675)Surge current resistance (8/20 µs wave):maximum 10 kAProtection level (1.5/50 µs wave): ‹ 1200 V(L/N against PE)

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS20032_E

DOS20031_E

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 218

Page 229: Shkaf Knurr Electronics e

by knürr

219

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Safety StandardStandard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price883 13 03.418.013.x 1 unit732 9 03.418.109.x 1 unit683 9 03.418.009.x 1 unit532 5 03.418.105.x 1 unit483 5 03.418.005.x 1 unit

- With overvoltage protection- With integrated mains filter- With back-lit switch, 2-pole switching- A combination of varistors and gas

discharge arresters guarantee a rapidresponse and a high discharge capacity

- Simple but effective protection against indi-rect strikes and interfering pulses from themains and high-frequency disturbance sig-nals

- Overvoltage protection:- 1. Up to maximum surge current resistance,

transient overvoltages are lowered to harm-less values - 2. If the surge current resistance is excee-

ded the connected equipment is separatedfrom the mains as protection against fur-ther overvoltage spikes (green functiondisplay goes out). For further use, the pro-tection module can then be exchanged.For increasing the protection function, acoarse filter should should be installed inadvance in the building installation.

- Mains filter:- High-frequency disturbance signals are

effectively eliminated with the high-stopmains filter

- 2 Models: standard sides or design sides - 19’’ Installation option

(with length 483 mm)- Socket rotation: 45°- Cable: HO5VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyFinal digit of order number .6:Enclosure, RAL 2003 pastel orangePlastic components: RAL 7035 light-grey

Technical dataMains voltage 230 VAC +/- 10 %Nominal current 16 AFeature class: D (refined protection inaccordance with DIN VDE 0675)Surge current resistance (8/20 µs wave):maximum 10 kAProtection level (1,5/50 µs wave): ‹ 1200 V(L/N against PE)Mains filter (low pass): attenuation with 1MHz, › 45 dB

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS20034_E

DOS20033_E With overvoltage protectionand mains filter

With overvoltage protectionand mains filter

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 219

Page 230: Shkaf Knurr Electronics e

by knürr

220

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Master-SlaveStandard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price683 9 03.414.009.1 1 unit483 5 03.414.005.1 1 unit

- If the master equipment is switched, theslave sockets are also switched (together,with short delay to the master).Consequently, convenient on-off switchingof several difficult to access devices.Switching thresholds can be set from outsi-de via the potentiometer

- Note:- Power consumption of the master equip-

ment must be constantly over the swit-ching on threshold. When switching offthe master equipment, the power con-sumption must fall below the switchingoff threshold.

- 19’’ Installation option(with length 483 mm)

- Socket rotation: 45°- Cable H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/16 A

Technical dataThreshold setting rangeOn: 20 mA - 200 mA (supply status, ca 55 mA )Off: 16 mA - 160 mA (supply status, ca 44 mA )Switching delay 550 ms +/- 20 %Electronic module, 2-pole switching

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS20035_E With master-slave module

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 220

Page 231: Shkaf Knurr Electronics e

by knürr

221

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip CombiStandard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price782 9 03.420.109.1 1 unit733 9 03.420.009.1 1 unit582 5 03.420.105.1 1 unit533 5 03.420.005.1 1 unit

- Master-slave with overvoltage protectionand mains filter

- Automatic switching of equipment with inte-grated overvoltage protection and mains filter

- Joint functions of the master-slave (page 220) and the safety standard (page 219)

- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Technical dataOvervoltage protection and mains filterMains voltage: 230 VAC +/- 10 %Nominal current 16 AFeature class: D (refined protection inaccordance with DIN VDE 0675)Surge current resistance (8/20 µs wave):maximum 10 kAProtection level (1,5/50 µs wave):‹ 1500 V (L + N against PE)Mains filter (low pass): attenuation with 1MHz, › 45 dBMaster-slave functionThreshold setting rangeOn: 20 mA - 200 mA (supply status, ca. 55 mA )Off: 16 mA - 160 mA (supply status, ca. 44 mA )Switching delay, 550 ms +/- 20 %Electronic module, 2-pole switching

Supply schedule1 Socket strip2 Mounting brackets

DOS20037_E

DOS20036_E

Master-slave, transition protection

and mains filter

Master-slave, transition protection

and mains filter

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 221

Page 232: Shkaf Knurr Electronics e

by knürr

222

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Compact GST 18 Plug System (Wieland)Standard CEE 7 V (UTE) / FranceL S n F1 F2 19“ Safe Model Order no. UP Price583 6 with switch 03.402.206.1 1 unit433 3 with switch 03.402.203.1 1 unit533 7 03.400.207.1 1 unit383 4 03.400.204.1 1 unit

- Quick, straightforward plug connectionsystem

- Plug electro-installation in place of conven-tional wiring

- Speed:- Due to straightforward plugging together

of pre-configured elements- Flexibility:

- Due to the cable (cable length)- Efficient:

- Convenient exchange of socket strips, withno cabling expense

- Safety:- Due to plug systems, all faulty installati-

ons are excluded- Space-saving:

- Use of protection and switching functionscan be extended to additional socket stripswith no loss of plugging space by exten-ding cabling (maximum load rating 16A)

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/10 A

Supply schedule1 Socket strip2 Mounting brackets

DOS20048_E

DOS20047_E

Di-Strip Safety BasicWith GST18 plug system / FranceL S n F1 F2 19“ Safe Model Order no. UP Price433 4 03.416.204.1 1 unit

- With overvoltage protection- Technical description, see page 218

Di-Strip Safety StandardWith GST18 plug systemL S n F1 F2 19“ Safe Model Order no. UP Price583 5 03.418.205.1 1 unit

- With overvoltage protection, with integratedmains filter and back-lit switch

- Technical description, see page 219

Di-Strip Safety SlaveWith GST18 plug systemL S n F1 F2 19“ Safe Model Order no. UP Price533 5 03.414.205.1 1 unit

- Technical description, see page 220

GST18 With switch

GST18 Without switch

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 222

Page 233: Shkaf Knurr Electronics e

by knürr

223

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

DOS00467_E

DOS00469_E

DOS00471_E

DOS00470_E

Power Supply LineFor GST18 plug systemL S n F1 F2 19“ Safe Model Order no. UP Price2000 04.000.040.0 1 unit5000 04.000.041.0 1 unit

- Mains plug CEE/VII - GST 18 socket(Wieland)

- Line, H05VV-F 3G 1.5 mm2

ColourWhite

Connection LineFor GST18 plug systemL S n F1 F2 19“ Safe Model Order no. UP Price1000 04.000.044.0 1 unit5000 04.000.045.0 1 unit

- GST18 Plug - GST 18 socket- Line, H05VV-F 3G 1.5 mm2

ColourWhite

GST18 Socket PartInputL S n F1 F2 19“ Safe Model Order no. UP Price

04.000.046.0 1 unit

- With screw terminal for cross-section, 1.5-2.5 mm2 with cable strain relief

- For individual, customer-side connection

Colour White

GST18 Plug PartOutputL S n F1 F2 19“ Safe Model Order no. UP Price

04.000.047.0 1 unit

- With screw terminal for cross-section, 1.5-2.5 mm2 with cable strain relief

- For individual, customer-side additionalcabling

ColourWhite

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 223

Page 234: Shkaf Knurr Electronics e

by knürr

224

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip ClassicStandard CH SEV 1011L S n F1 F2 19“ Safe Model Order no. UP Price1783 17 03.700.067.x 1 unit1383 13 03.700.063.x 1 unit

983 9 03.700.059.x 1 unit583 5 03.700.055.x 1 unit

1733 16 with switch 03.702.066.x 1 unit1333 12 with switch 03.702.062.x 1 unit

933 8 with switch 03.702.058.x 1 unit533 4 with switch 03.702.054.x 1 unit

- With/without switch, socket spacing,100 mm

- Optional with back-lit switch,2-pole switching

- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyFinal digit of order number .6:Enclosure, RAL 2003 pastel orangePlastic components: RAL 7035 light-grey

Load rating250 VAC/10 A

Supply schedule1 Socket strip2 Mounting brackets

Di-Strip CompactStandard CH SEV 1011L S n F1 F2 19“ Safe Model Order no. UP Price883 15 03.700.015.1 1 unit732 11 03.700.111.1 1 unit683 11 03.700.011.1 1 unit532 7 03.700.107.1 1 unit483 7 03.700.007.1 1 unit382 4 03.700.104.1 1 unit333 4 03.700.004.1 1 unit732 10 03.702.110.1 1 unit683 10 with switch 03.702.010.1 1 unit532 6 with switch 03.702.106.1 1 unit483 6 with switch 03.702.006.1 1 unit382 3 with switch 03.702.103.1 1 unit333 3 with switch 03.702.003.1 1 unit

- Optional with back-lit switch,2-pole switching

- 19“ Installation option (with length 483 mm)- 2 Models, standard sides or design sides- Socket rotation: 45º- Cable: H05VV-F 3G 1.5 mm2

- Moulded plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/10 A

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS00717_E

DOS00664_E

DOS00665_E

DOS20074_E

DOS20039_E

DOS00666_E

DOS00667_E

DOS20038_E

Classic with switch

Classic without switch

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 224

Page 235: Shkaf Knurr Electronics e

by knürr

225

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard sidesF2 = Design sides, 19”= Suitable for 19” installation, Safe = Child-safe

Di-Strip Protector FI / LSStandard CH SEV 1011L S n F1 F2 19“ Safe Model Order no. UP Price683 9 03.710.009.1 1 unit483 5 03.710.005.1 1 unit

Protector FI / LS- RCCB and circuit breaker- Provides a combination of user, over-

load and short-circuit protection - Residual operating current I = 30 mA

for alternating and pulsating faultdirect current

- Circuit breaker 10 A- Tripping characteristic

type B, 2-pole- 19’’ Installation option

(with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Load rating250 VAC/10 A

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

Di-Strip Safety StandardStandard CH SEV 1011L S n F1 F2 19“ Safe Model Order no. UP Price683 9 with switch 03.718.009.1 1 unit483 5 with switch 03.718.005.1 1 unit

- With overvoltage protection and integratedmains filter

- With back-lit switch,2-pole switching

- 19’’ Installation option (with length 483 mm)- Socket rotation: 45°- Cable: H05VV-F 3G 1.5 mm2

- Moulded plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 V0), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 50 mmHeight: 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2, 5 m

ApprovalsCE Label in accordance with low voltageguideline,73/23/EWG, EMC guideline89/336/EWG

Colour combinationFinal digit of order number .1:RAL 7035 light-greyPlastic components: RAL 7035 light-grey

Description and technical dataSee page 209

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19" installation option)

DOS00719_E

DOS00668_E

DOS00720_E

DOS00669_E With transition protectionand mains filter

201-225_eng_final.qxd 07.08.2002 15:52 Uhr Seite 225

Page 236: Shkaf Knurr Electronics e

by knürr

226

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard side pieceF2 = Design side piece, 19”= Suitable for 19” inst., Safe = Chlid-safe

Di-Strip Euro Socket System, IEC 320With cable and right angle plugL S n F1 F2 19“ Safe Model Order no. UP Price483 9 with switch 03.602.009.1 1 unit333 6 03.600.006.1 1 unit

- Optional with back-lit switch,2-pole switching

- 19’’ Installation option- With 3-way Euro combinations from IEC 320

sockets- Cable: H05VV-F 3G 1.5 mm2

- Cable: 2.5 m- Moulded right angle plug, CEE7/VII- Without fuse protection

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 VO), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 24 mmHeight, 45.5 mmEnclosure width: 44.4 mm (= 1 HU)

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

ColourEnclosure: RAL 7035 light-greyPlastic components: RAL 7021 dark-grey

Load rating250 VAC/10 A

Compliance symbols for IEC 320 3-wayEuro combinationVDE, UL, CSA, SEV, SEMKO

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

Di-Strip Euro Socket System, IEC 320Euro input in plug fieldL S n F1 F2 19“ Safe Model Order no. UP Price383 6 03.622.006.1 1 unit483 9 03.622.009.1 1 unit

433 6 with switch 03.624.006.1 1 unit

- With fine-wire fuse 10 A- Optionally with back-lit switch,

2-pole switching- 19“ Installation option- With 3-way Euro combinations from IEC 320

sockets

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 VO), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 24 mmHeight, 45.5 mmEnclosure width: 44.4 mm (= 1 HU)

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

ColourEnclosure: RAL 7035 light-greyPlastic components: RAL 7021 dark-grey

Load rating250 VAC/10 A

Compliance symbols for IEC 320 3-wayEuro combinationVDE, UL, CSA, SEV, SEMKO

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS20062_E

DOS00498_E

DOS20042_E

DOS00458_E

DOS20041_E

DOS20040_E

With switch

Without switch

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 226

Page 237: Shkaf Knurr Electronics e

by knürr

227

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard side pieceF2 = Design side piece, 19”= Suitable for 19” inst., Safe = Chlid-safe

Di-Strip Euro Socket System, IEC 320Euro input on side panelL S n F1 F2 19“ Safe Model Order no. UP Price333 6 03.622.706.1 1 unit433 9 03.622.709.1 1 unit

383 6 with switch 03.624.706.1 1 unit483 9 with switch 03.624.709.1 1 unit

- With fine-wire fuse 10 A- Optionally with back-lit switch,

2-pole switching- 19“ Installation option- With 3-way Euro combinations from IEC

320 sockets

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 VO), recycleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 24 mmHeight, 45.5 mmEnclosure width: 44.4 mm (= 1 HU)

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

ColourEnclosure: RAL 7035 light-greyPlastic components: RAL 7021 dark-grey

Load rating250 VAC/10 A

Compliance symbols for IEC 320 3-wayEuro combinationVDE, UL, CSA, SEV, SEMKO

Supply schedule1 Socket strip2 Mounting brackets

DOS00460_E

DOS00461_E

DOS20044_E

DOS20043_E

Mains Cable for Euro Socket StripFor DIN 49 440 and French / Belgian standardL S n F1 F2 19“ Safe Model Order no. UP Price2000 04.000.054.9 1 unit5000 04.000.050.9 1 unit

- Mains plug CEE/VII - Euro socket IEC 320- Line, H05VV-F 3G 1 mm2

Mains voltage250 VAC

Nominal current10 A

Mains Cable for Euro Socket StripFor Swiss standardL S n F1 F2 19“ Safe Model Order no. UP Price2000 04.000.055.9 1 unit

- Mains plug: type 12 - Euro socket IEC 320- Line, H05VV-F 3G 1 mm2

Mains voltage250 VAC

Nominal current10 A

Without switch

DOS00076_E

DOS00077_E

With switch

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 227

Page 238: Shkaf Knurr Electronics e

by knürr

228

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard side pieceF2 = Design side piece, 19”= Suitable for 19” inst., Safe = Chlid-safe

Di-Strip CompactStandard UK BS1363AL S n F1 F2 19“ Safe Model Order no. UP Price1033 12 03.801.012.1 1 unit

733 8 03.801.008.1 1 unit483 4 03.801.004.1 1 unit

1083 12 with switch 03.803.012.1 1 unit783 8 with switch 03.803.008.1 1 unit483 4 with switch 03.803.004.1 1 unit

- Optionally with back-lit switch,2-pole switching

- 19’’ Installation option- Mains plug including fuse 13A

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 VO), recycleableCable: PVC

DimensionsSocket spacing: 24 mmHeight, 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2.5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationEnclosure: RAL 7035 light-greyPlastic components: RAL 7021 dark-grey

Load rating250 VAC/10 A

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS00078_E

DOS00519_E

DOS80001_E

Mains Cable for Euro Socket StripFor British standardL S n F1 F2 19“ Safe Model Order no. UP Price2000 04.000.056.9 1 unit

- Mains plug: type BS 1363 - Euro socket IEC320

- Line, H05VV-F 3G 1 mm2

Mains voltage250 VAC

Nominal current10 A

Euro Connection LineL S n F1 F2 19“ Safe Model Order no. UP Price900 04.000.051.9 1 unit

- Mains plug: IEC 320 - Euro socket IEC 320- Line, H05VV-F 3G 1 mm2

Mains voltage250 VAC

Nominal current10 A

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 228

Page 239: Shkaf Knurr Electronics e

by knürr

229

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard side pieceF2 = Design side piece, 19”= Suitable for 19” inst., Safe = Chlid-safe

Di-Strip Safety BasicStandard UK BS1363AL S n F1 F2 19“ Safe Model Order no. UP Price483 4 03.817.004.1 1 unit

- With overvoltage protection- A combination of varistors and gas dis-

charge arresters guarantee a rapid respon-se and a high discharge capacity

- Simple but effective protection against in-direct strikes and interfering pulses fromthe mains

- 19“ Installation option- Mains plug including fuse 13A

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94VO), recycleableCable: PVC

DimensionsSocket spacing: 75 mmHeight, 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2.5 m

ApprovalsCE Label in accordance with low voltageguideline, 73/23/EWG, EMC guideline89/336/EWG

Colour combinationEnclosure: RAL 7035 light-greyPlastic components: RAL 7021 dark-grey

Load rating250 VAC/10 A

Technical dataNominal voltage: 230 VAC +/- 10%Nominal current 16AFeatures class: D (refined protection inaccordance with DIN VDE 0675)Surge current resistance (8/20µs wave):maximum 10kAProtection level (1.5/50µs wave): ‹ 1200 V(L/N against PE)

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

Di-Strip ClassicStandard USA NEMA5L S n F1 F2 19“ Safe Model Order no. UP Price1383 12 with switch 03.532.062.1 1 unit

- With back-lit switch- With overload protection 15 A- Cable: SJT 14 AWG x 3C- Moulded plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94VO), recycleable

DimensionsSocket spacing: 100 mmHeight, 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2.5 m

ApprovalsCE / CSA / CSA US

Colour Enclosure: RAL 7035 light-greyPlastic components: RAL 7021 dark-greySocket parts and cable, RAL 9011, graphite black

Load rating250 VAC/10 A

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

DOS00670_E

DOS80002_E

DOS00685_E

with switch

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 229

Page 240: Shkaf Knurr Electronics e

by knürr

230

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard side pieceF2 = Design side piece, 19”= Suitable for 19” inst., Safe = Chlid-safe

Di-Strip CompactStandard USA NEMA5L S n F1 F2 19“ Safe Model Order no. UP Price483 9 with switch 03.532.009.1 1 unit383 6 with switch 03.532.006.1 1 unit

- With back-lit switch- With overload protection 15 A- 19” Installation option (with length 483 mm)- Cable: SJT 14 AWG x 3C- Moulded plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94VO), recycleable

DimensionsSocket spacing: 32 mmHeight, 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2.5 m

ApprovalsCE / CSA / CSA US

Colour Enclosure: RAL 7035 light-greyPlastic components: RAL 7021 dark-greySocket parts and cable, RAL 9011, graphite black

Load rating250 VAC/10 AMains frequency 60 Hz

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets (additional

with 19’’ installation option)

Di-Strip Surge ProtectorStandard USA NEMA5L S n F1 F2 19“ Safe Model Order no. UP Price483 6 with switch 03.534.006.1 1 unit

- With back-lit switch- With overload protection 15 A- With overvolatge protection- 19” Installation option (with length 483 mm)- Cable: SJT 14 AWG x 3C- Moulded plug

Material / FinishEnclosure: closed sheet steel extrusion,zinc passivated, powder-coated, texturedPlastic components: Polyamid PA 6 (UL 94 VO), recycleable

DimensionsSocket spacing: 32 mmHeight, 45.5 mmEnclosure width: 44.4 mm (= 1 HU)Cable: 2.5 m

ApprovalsCE / CSA C / CSA US

ColourEnclosure RAL 7035 light-greyPlastic components: RAL 7021 dark-greySocket parts and cable, RAL 9011, graphite black

Technical dataNominal voltage 125 VACNominal current 15 AMains frequency 60 HzSurge current resistance (8/20 µs wave):maximum 13 kAProtection level (1,5/50 µs wave): ‹ 400 V(measured in accordance with UL 1449)

Supply schedule1 Socket strip2 Mounting brackets2 19’’ Mounting brackets

DOS20016_E

DOS20017_E

DOS00686_E

DOS00687_E

With switch

With overvoltage protection

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 230

Page 241: Shkaf Knurr Electronics e

by knürr

231

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard side pieceF2 = Design side piece, 19”= Suitable for 19” inst., Safe = Chlid-safe

Serimat ClassicL S n F1 F2 19“ Safe Model Order no. UP Price

563 5 03.002.305.2963 9 03.002.309.2

1363 13 03.002.313.21763 17 03.002.317.2

543 4 with switch 03.000.304.2943 8 with switch 03.000.308.2

1343 12 with switch 03.000.312.21743 16 with switch 03.000.316.2

- Optionally with back-lit switch, 2-pole switching

- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: robust, double-panelled sheetsteel enclosure, powder-coated, textured

DimensionsSocket spacing: 100 mmHeight: 45 mmEnclosure width: 51 mm Cable: 2.5 m

ApprovalCE Label in accordance with low voltageguideline 73/23/EWG, EMC guideline89/336/EWGVDE Certificate

ColourRAL 2003 Pastel orange

Load rating250 VAC/16A

Supply schedule1 Socket strip

Serimat CompactL S n F1 F2 19“ Safe Model Order no. UP Price278 3 03.002.333.2408 5 03.002.335.2668 9 03.002.339.2928 13 03.002.343.2

408 4 with switch 03.000.334.2668 8 with switch 03.000.338.2928 12 with switch 03.000.342.2

- Optionally with back-lit switch, 2-pole switching

- Socket rotation: 30°- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: robust, double-panelled sheetsteel enclosure, powder-coated, texturedPlastic components: Polyamid PA 6, recyleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 60 mmHeight: 45 mmEnclosure width: 51 mm Cable: 2.5 m

ApprovalCE Label in accordance with low voltageguideline 73/23/EWG, EMC guideline89/336/EWGTÜV/GS Certificate

ColourRAL 2003 Pastel orange

Load rating250 VAC/16A

Supply schedule1 Socket strip

DOS20063_E

DOS00509_E

DOS20077_E

DOS00511_E With back-lit switch

DOS00510_E Without switch

Without switch

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 231

Page 242: Shkaf Knurr Electronics e

by knürr

232

POWER SUPPLY SYSTEMS

Dimensions in mm: L = Length, S = Switch, n = Number of sockets, F1 = Standard side pieceF2 = Design side piece, 19”= Suitable for 19” inst., Safe = Chlid-safe

Serimat Classic Black LineL S n F1 F2 19“ Safe Model Order no. UP Price361 4 03.009.004.2446 5 03.009.005.2531 6 03.009.006.2616 7 03.009.007.2

361 3 with switch 03.009.013.2446 4 with switch 03.009.014.2531 5 with switch 03.009.015.2616 6 with switch 03.009.016.2

- Optionally with back-lit switch, 2-pole switching

- Cable: H05VV-F 3G 1.5 mm2

- Moulded right angle plug

Material / FinishEnclosure: robust, double-panelled sheetsteel enclosure, powder-coated, texturedPlastic components: Polyamid PA 6, recyleableInner conductor: continuous busbar,brassCable: PVC

DimensionsSocket spacing: 85 mmHeight: 45 mmEnclosure width: 60 mm Cable: 2.5 m

ApprovalCE Label in accordance with low voltageguideline 73/23/EWG, EMC guideline89/336/EWGVDE Certificate

ColourRAL 2003 Graphite black

Load rating250 VAC/16A

Supply schedule1 Socket strip

DOS20064_E

Bild 5_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 232

Page 243: Shkaf Knurr Electronics e

Strong Points and technical details Page 234Product Page 236

tecoras DC Backup Systems (UPS)

tecoras

by knürr

233

POWER SUPPLY SYSTEMS

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 233

Page 244: Shkaf Knurr Electronics e

by knürr

234

POWER SUPPLY SYSTEMS

- Door contacts etc.

Modular power supply unit withcharge controller- Output 200 W … 3750 Watt- For indoor or outdoor

applications- In the modular chassis,

equipped with,- 1…5 PSU Module cascadable,

redundancy and easy futureupgrade possible

- Charge controller with monito-ring function

- Integrated DC distribution possible as per power requi-rement

Dart fan unit, 1 HUFan unit for specific convection ofthe PSU module

Batteries- Power supply takeover in the

event of a mains supply failurein the DC circuit of connectedequipment

- The most varied battery confi-gurations possible for yourbackup time requirements

6

6

5

External AC distributionConfiguration and equipping tosuit requirements(Rackpower distribution box)

AC/DC DistributionAs compact 19" unit / 3 HU orintegrated in the power supplyunit with:- Primary fuse protection- Euro sockets for connecting

PSU modules- Service sockets

with RCCB fuse protection- Monitored output fuses in the

DC circuit- Output terminals

for DC circuit- Battery fuse- Battery protectiondepending on the model.

Input boxConsisting of:- Monitored overvoltage protec-

tion - Bushing-type filter for signal

lines- Supply terminal block- On request with integrated AC

distribution

Sensor systemA wide range of application-oriented sensor systems are available, for example:- Smoke detector- Water level detector- Temperature detector

4

3

2

1

DC Backup SystemsStrong points

TEC20016_E

HEI00393_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 234

Page 245: Shkaf Knurr Electronics e

by knürr

235

POWER SUPPLY SYSTEMS

The power systemConsists of the following individualcomponents:- 1 to 5 piece 200 W or 750 W

rectifier modules, 15 HP(1 HP = 5.08 mm)

- Charge monitor module, 9 HP- Backplane for mounting the indivi-

dual modules- 19" Modular chassis

Height 3 HU (1 HU = 44.45 mm),depth 285 mm (200 W rectifier)or depth 340 mm (750 W rectifier)

Various freely-selectable combina-tion options can be designed withthe modular concept.The integrated charge controllermonitors the batteries in the UPSoperation and ensures optimal bat-tery charging.Using connected sensors anddepending on the requirements, itadditionally monitors the environ-mental conditions in the rack as wellas monitoring the power modulesand controlling battery tests.If an uninterruptible power supplyfunctionality is not required, thepower supply can also be operatedwithout batteries and charge controller. Depending on the number of PSUmodules, output power of up to1,000 W or 3750 W, can be realisedin each 200 or 750 W stage.With output of up to 600 W or 2250 W (3 modules), a DC distributorcan be integrated in the modularchassis.

The BCU as charge monitoringmodule takes on multiple monitoringand control functions:

Charging- Battery charging control- Optimal charge current adaption

due to battery temperature measu-ring (maximum permissible con-stant current for minimum battery charging time)

- Separation of battery from load cir-cuit before reaching battery deepdischarge state

- Float charge on reaching the volta-ge at the beginning of gassing(with constant voltage)

Monitoring- Power supply module monitoring

(PSU)- Battery capacity tests- Registering and linking of connec-

ted monitoring sensor systems

Communication- Transmission of analysis and alarm

data via serial and binary interfa-ces

- Display of operating and alarm sta-tes via LEDs and LC display

Sensor systems- Auxiliary supply for sensor systems- Programming of sensor

evaluations

DC Backup SystemsTechnical data, power system with battery buffer

TEC00056_E

TEC00445_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 235

Page 246: Shkaf Knurr Electronics e

by knürr

236

POWER SUPPLY SYSTEMS

Power System, MAXI DC UPS 750 W

Technical dataOutput power 750 W with 230 V

AC supply500 W with 115 V ACsupply

Characteristic Current/voltage with temperature-regulated adaption

Ventilation With convection forced cooling withTu › 35º C

Operating temp. –10° C to +60° CrangeStorage temp. –40° C to +85° CrangeHumidity 30% to 95% (no

dewfall)Input voltage 100 V AC …240 V ACrange nominalEfficiency 90% at full load

(Ue = 240 V)Output factor › 0.9 in acc. with (with full load) EN 61000-3-2Input current 25 A with 265 V AClimitOutput power 750 W

(TU =25° C) Convection750 W (TU = 50° C)Fan(v L = 1.5 m/s)

Output voltage 48 V DCSetting range of the 42 V DC to 585 Voutput voltage DC, short circuit-

proofStandards EN 55022B,

EN 61000-3-2,EN 61000-4 part 2,3, 4, 5 level 3,ETS 300 339,ETS 300 342-2,GSM 11.22,EN 60950, VDE 0160,UL 1950, UL 1459

MTBF ›100,000 hrs MIL HDBK 217 F

Dimensions Width 15 HP,Height 3 HU,Depth 295 mm

Power System, MIDI DC UPS 200 W

Technical dataOutput power 200 W regulated at

115/230 V AC(230 V AC with con-vective cooling)

Regulation Current-regulated(with temperature-regulated adaption)

Efficiency › 85% at full loadOutput factor › 0.8 in acc. with

EN 6100-3-2Ventilation ConvectionDerating From Tu 35° COperating temp. 0°C to +60° Crange (switch-off at

› 60° C)Storage temp. -40° C to +85° CrangeHumidity 30% to 95%

(no condensationmoisture)

Voltage range 100 V AC … 240 V ACInput current 5 AlimitOutput voltage 48 V DCStandards EN 55022B,

EN 61000-3-2,EN 6100-4 part 2-5,EN 50081-1,EN 50082-2,EN 60950,VDE 0160

Structure in acc. withUL 1950,UL 1459

MTBF › 100,000 hrs MIL HDBK 217 F

Dimensions Width 15 HPHeight 3 HUDepth 220 mm

HEI00406_1_E

HEI00406_2_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 236

Page 247: Shkaf Knurr Electronics e

by knürr

237

POWER SUPPLY SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightP (W) = Output power

Final digit of order number:.1 = RAL 7035

Power System, MAXI DC UPS 750 W19“ DC UPS MAXI 7 HU with external distributionP (W) kg Model Order no. UP Price

750 17.1 06.103.000.1 1 unit1500 19.2 06.103.010.1 1 unit2250 21.3 06.103.020.1 1 unit3000 23.4 06.103.030.1 1 unit3750 25.5 06.103.040.1 1 unit

Battery configuration is possible as requiredin a separate battery tray. We are pleased tobe able to offer you the appropriate batteriesfor your required back-up times.

DimensionsWidth 19"Height 7 HUDepth 340 mm

Supply schedule1 Modular chassis, 3 HU with backplane

equipped with - 1…5 Rectifier module, 750 watt- Charge controller, BCU

1 Fan unit, 1 HU1 AC/DC Distributor, 3 HU with

- AC Input protection- Service sockets with RCCB- DC Output terminals with fuse protec-

tion

19“ DC UPS, MAXI 3 HU with Integrated DistributionP (W) kg Model Order no. UP Price

750 9.4 06.103.001.1 1 unit1500 11.5 06.103.011.1 1 unit2250 13.6 06.103.021.1 1 unit

Battery configuration is possible as requiredin a separate battery tray. We are pleased tobe able to offer you the appropriate batteriesfor your required back-up times.

DimensionsWidth 19"Height 3 HUDepth 340 mm

Supply schedule1 Modular chassis, 3 HU with backplane

equipped with- 1…3 Rectifier module, 750 watt- Charge controller, BCU- 1 DC Distribution, 3 HU with output

terminals and fuse protection

Power System, MIDI DC UPS 200 W19“ DC UPS MIDI 3 HU for external distributionP (W) kg Model Order no. UP Price200 7.0 06.104.102.1 1 unit400 8.1 06.104.202.1 1 unit600 9.2 06.104.302.1 1 unit800 10.3 06.104.402.1 1 unit1000 11.4 06.104.502.1 1 unit

Battery configuration is possible as requiredin a separate battery tray. We are pleased tobe able to offer you the appropriate batteriesfor your required back-up times.

DimensionsWidth 19"Height 3 HUDepth 285 mm

Supply schedule1 Modular chassis, 3 HU with backplane

equipped with- 1…5 Rectifier module, 750 watt- Charge controller, BCU

HEI00400_E

HEI00409_E

HEI00412_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 237

Page 248: Shkaf Knurr Electronics e

by knürr

238

POWER SUPPLY SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightP (W) = Output power, * = Backup time in minutes, ** = Backup time in hours

Final digit of order number:.1 = RAL 7035

19“ DC UPS MIDI 3 HU with Integrated DistributionP (W) kg Model Order no. UP Price200 7.8 06.104.132.1 1 unit400 9.0 06.104.232.1 1 unit600 10.2 06.104.332.1 1 unit

Battery configuration is possible as requiredin a separate battery tray. We are pleased tobe able to offer you the appropriate batteriesfor your required back-up times.

DimensionsWidth 19"Height 3 HUDepth 285 mm

Supply schedule1 Modular chassis, 3 HU with backplane

equipped with- 1…3 Rectifier module, 200 watt- Charge controller BCU- 1 DC Distibutor, 3 HU with output ter-

minals and fuse protection

Power System, MIDI Compact I... IV DC UPS 200 W19“ DC UPS MIDI Compact, 6 HU with integrated battery packmin* W kg Model Order no. UP Price180 200 31.0 UPS MIDI Compact I 06.104.111.1 1 unit

90 400 32.5 UPS MIDI Compact I 06.104.211.1 1 unit45 600 34.0 UPS MIDI Compact I 06.104.311.1 1 unit

180 200 31.0 UPS MIDI Compact I 06.104.121.1 1 unit90 400 32.5 UPS MIDI Compact II 06.104.221.1 1 unit45 600 34.0 UPS MIDI Compact II 06.104.321.1 1 unit

180 200 31.0 UPS MIDI Compact III 06.104.112.1 1 unit90 400 32.5 UPS MIDI Compact III 06.104.212.1 1 unit45 600 34.0 UPS MIDI Compact III 06.104.312.1 1 unit

180 200 31.0 UPS MIDI Compact IV 06.104.122.1 1 unit90 400 32.5 UPS MIDI Compact IV 06.104.222.1 1 unit45 600 34.0 UPS MIDI Compact IV 06.104.322.1 1 unit

19" DC UPS MIDI Compact I, 6 HUwiht integrated battery pack

DimensionsWidth 19"Height 6 HUDepth 285 mm

Supply schedule1 Modular chassis, 6 HU equipped with

- 1…3 Recitfier module, 200 W- Charge controller, 9 HP (without dis-

play/ RS-232 interface)- Integrated battery pack, 13 Ah- Integrated DC distribution with output

fuses19" DC UPS MIDI Compact II, 6 HU

Supply schedule same as Compact I, but with

- Integrated DC distribution with outputfuse switches

19" DC UPS MIDI Compact III, 6 HUSupply schedule same as Compact I, but with

- Charge controller, 9 HP with LC display/RS-232 interface

19" DC UPS MIDI Compact IV, 6 HUSupply schedule same as Compact I, but with

- Charge controller, 9 HP with LC display/RS-232 interface

- Integrated DC distribution with circuitbreakers

HEI00414_E

HEI00402_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 238

Page 249: Shkaf Knurr Electronics e

by knürr

239

POWER SUPPLY SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightP (W) = Ouput power, * = Backup time in minutes, ** = Backup time in hours

Final digit of order number:.1 = RAL 7035

Power System, MIDI Compact V DV UPS 200 W19“ DC UPS MIDI Compact V, 3 HU with integrated battery packmin W kg Model Order no. UP Price30 200 14.8 06.104.100.1 1 unit10 400 16.0 06.104.200.1 1 unit

DimensionsWidth 19"Height 3 HU with modular chassisDepth 285 mm

Supply schedule1 Modular chassis, 3 HU equipped with

- 1…2 Rectifier module, 200 W- Charge controller, 9 HP- Integrated battery pack, 4 Ah- Integrated DC distribution with output

fuses

Power System, MINI DC UPS 25 W19“ DC UPS MINI, 1 HU with integrated battery packh W kg Model Order no. UP Price4 25 5 06.104.900.1 1 unit

Supply schedule- Power supply, 48 V / 25 watt- Integrated battery pack for 4 hours

backup time- DC Output and signal outputs via SUB-D

socket- Alarm messages for

- mains voltage- charge regulator monitoring- battery partial discharge- battery deep discharge

DimensionsWidth 19"Height 1 HUDepth 225 mm

Models with other outputs, voltages, backuptimes and signalling are also available onrequest.

Distributor Boxh W kg Model Order no. UP Price

03.013.385.1 1 unit

- For mounting installation engineering DINrail components such as fuses, terminals,relays etc.

- When installed, the mounting level can bepulled out to the front and interlocked, thusconsiderably facilitating the wiring of indivi-dual components

- Installation space for up to 22 installationdevices of 18 mm width each

- Mounting of the TS35 DIN rail on severallevels due to simple plug-in connection

- "Snap-in" mounting of DIN rail components - Free access to protective earth and neutral

conductor rail from the front- Different positioning options prepared for N

and PE rails have been prepared- Cable entry at the back via double brush

strip (optional via bushes)- Internal strain relief and thus accessible

from the front- Front labelling above and below the installa-

tion space- Power uses for power distribution at 230 V

AC, but also in the low voltage range (e.g. 48V DC)

- 19" Chassis, 3 HU, depth 150 mm

Material / Finish- Covers, powder-coated

RAL 7035 light-grey, textured- Main unit, sheet steel, zinc passivated

Supply schedule1 Distribution boxIncluding N and PE rails, cable entry,strain relief, empty panel covers and earthing kit

How suppliedFully assembled

HEI00416_E

HEI00404_E

HEI00379_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 239

Page 250: Shkaf Knurr Electronics e

by knürr

240

POWER SUPPLY SYSTEMS

Final digit of order number:.1 = RAL 7035

Cable Entry for Distribution BoxModel Order no. UP Price

03.013.386.1 1 unit

Alternative to cable entry via brush strip withmounting the distribution box in open racks

Material / FinishSheet steel, zinc passivated

Supply schedule1 Cable entry panel

11 Bushing socketsMounting material

HEI00234_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 240

Page 251: Shkaf Knurr Electronics e

Strong Points and technical details Page 242Product Page 243

dart Ventilation Systems

Product Page 249

Cooling Systems

Product Page 252

Heating Systems

climate

by knürr

241

THERMAL SYSTEMS

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 241

Page 252: Shkaf Knurr Electronics e

by knürr

242

THERMAL SYSTEMS

Easy filter change while operating: Fresh air from outsideincreases the cooling perform-ance. A built-in filter mat therebyprotects your components fromcontamination.The filter mat is changed at thefront – this can be done while theunit is operating.The front panel is removed withquick-release fasteners.Downtimes are consequentlyavoided.

The airmatic 19“ tangential fanis the ideal ventilation insert formodular chassis’ with printed cir-cuit boards in Eurocard format.A uniform cooling of the electro-nics is guaranteed with an evenlydistributed airflow over the entirewidth of the unit. The airflowmonitoring signals dirt build-upon the filter mat and fan failure ingood time, and consequently pro-tects the installations fromoverheating.

With increased requirements withregard to IP protection (water/dust)and very high power loss of the elec-tronics, heat exchangers and cool-ling equipment are utilised.

6

5Heat transfer by ventilation (forcedconvection) is a very effectivemethod.19“ Fan units provide forced air flowthrough the enclosure.Hot spots are targetted and elimina-ted with single fans and fan frontpanels.Fan installation sets and stackablefans can also be integrated later on.

The specialised ventilation sys-tem of the dart fan unit providesuniform through flow for all elec-tronics that require cooling.Marginal areas are also cooled inthe process. Conventional posi-tioning of axial fans is known tocause numerous unventilatedareas.

No heat build-up under the fan:With modular chassis’ that liebelow the fan, the specialiseddesign of the 2 HU fan unit ena-bles air dissipation to the rear.

Automatic regulation of the ven-tilation with temperature sensor.By adapting to the actual require-ments, the fans attain longer life-spans and lower noise levels.

The 19“ filter insert provides fil-tered air and thereby preventscontamination of your internalcomponents.

4

3

2

1

dartStrong points

LUF00269_E1

LUF00268_E1

LUF00278_E2

LUF00205_E4

LUF00279_1_E3

LUF00271_E5

LUF00206_E6

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 242

Page 253: Shkaf Knurr Electronics e

by knürr

243

THERMAL SYSTEMS

dart 19“ Vertical Fan unit1 HU/U, not regulatedW H D kg W n Model Order no. UP Price19” 43.6 193.5 3 230 VAC (207-243 VAC) 03.026.103.1 1 unit19” 43.6 385.5 6 230 VAC (207-243 VAC) 03.026.106.1 1 unit19” 43.6 193.5 3 115 VAC (104-121 VAC) 03.026.104.1 1 unit19” 43.6 385.5 6 115 VAC (104-121 VAC) 03.026.107.1 1 unit19” 43.6 193.5 3 24 VDC (12-28 VDC) 03.026.105.1 1 unit19” 43.6 385.5 6 24 VDC (12-28 VDC) 03.026.108.1 1 unit19” 43.6 193.5 3 48 VDC (43-53 VDC) 03.026.120.1 1 unit19” 43.6 385.5 6 48 VDC (43-53 VDC) 03.026.121.1 1 unit

- For vertical ventilation of 19” cabinets andenclosures

- For preventing hot spots- Uniform air distribution over the entire

width and depth of the fan unit- Chassis runners are required for the

mounting

MaterialSheet steel

Finish / ColourEnclosure, zinc passivatedFront panel, powder-coated, smooth,RAL 7035 light-grey

ApprovalsCE Identification in accordance with lowvoltage guideline 73/23/EWG,EMC guideline 89/336/EWG

TestsVibration test in accordance with MIL-STD810 E

Supply schedule1 Fan unit1 Connection cable, 2 m with safety plug

(230 VAC)1 Connection cable, 2 m US standard

(115VAC)1 Connection cable, 2 m without plug

(24 VDC)1 Connection cable, 2 m without plug

(48 VDC)

How suppliedAssembled, wired and tested

dart 19“ Fan Unit with Front Intake2 HU/U not regulatedW H D kg W n Model Order no. UP Price19” 88.1 193.5 3 230 VAC (207-243 VAC) 03.026.203.1 1 unit19” 88.1 193.5 3 115 VAC (104-121 VAC) 03.026.204.1 1 unit19” 88.1 193.5 3 24 VDC (12-28 VDC) 03.026.205.1 1 unit19” 88.1 193.5 3 48 VDC (43-53 VDC) 03.026.122.1 1 unit

- Increased cooling output with front intake - Filter mat can be changed at the front

during operation without need for tools - Uniform air distribution over the entire

width and depth of the fan unit

MaterialSheet steel

Finish / ColourEnclosure, zinc passivatedFront panel, powder-coated, smooth,RAL 7035 light-grey

ApprovalsCE Identification in accordance with lowvoltage guideline 73/23/EWG,EMC guideline 89/336/EWG

TestsVibration test in accordance with MIL-STD810 E

Supply schedule1 Fan unit1 Filter mat, Viledon P15/1501 Connection cable, 2 m with safety plug

(230 VAC)1 Connection cable, 2 m US standard

(115VAC)1 Connection cable, 2 m without plug

(24 VDC)1 Connection cable, 2 m without plug

(48 VDC)

How suppliedAssembled, wired and tested

LUF00279_E

LUF00272_E

LUF00283_2_E

LUF00273_E

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 243

Page 254: Shkaf Knurr Electronics e

by knürr

244

THERMAL SYSTEMS

dart-19“ Vertical Fan Unit1 HU/U, speed-controlledW H D kg W n Model Order no UP Price19” 43.6 193.5 3 115/230 VAC (93-256 VAC) 03.026.113.1 1 unit19” 43.6 385.5 6 115/230 VAC (93-256 VAC) 03.026.116.1 1 unit19” 43.6 193.5 3 24 VDC (12-28 VDC) 03.026.115.1 1 unit19” 43.6 385.5 6 24 VDC (12-28 VDC) 03.026.118.1 1 unit19” 43.6 193.5 3 48 VDC (36-72 VDC) 03.026.130.1 1 unit19” 43.6 385.5 6 48 VDC (36-72 VDC) 03.026.131.1 1 unit

- Temperature measuring via PTC sensorwith 2 m cable, can be plugged at the rear

- Required temperature can be set on thepotentiometer

- Fan control with 30-100% of the nominalpower, maximum rotation with temp. sensorfailure

- Individual fan monitoring- For vertical ventilation of 19” cabinets and

enclosures- For preventing hot spots- Uniform air distribution over the entire

width and depth of the fan unit- Chassis runners required for mounting

MaterialSheet steel

Finish / ColourEnclosure, zinc passivatedFront panel, powder-coated, smooth,RAL 7035 light-grey

ApprovalsCE Identification in accordance with lowvoltage guideline 73/23/EWG,EMC guideline 89/336/EWG

TestsVibration test in accordance with MIL-STD810 E

Supply schedule1 Fan unit1 Temperature sensor with cable, 2 m1 Signal cable, 2 m (can be plugged)1 Connection cable, 2 m with EURO plug

(115/230 VAC)1 Connection cable, 2 m without plug

(24 VDC)1 Connection cable, 2 m without plug

(48 VDC)

How suppliedAssembled, wired and tested

dart 19“ Fan Unit with Front Intake2 HU/U, speed-controlledW H D kg W n Model Order no. UP Price19” 88.1 193.5 3 115/230 VAC (93-256 VAC) 03.026.213.1 1 unit19” 88.1 193.5 3 (24 VDC) 03.026.215.1 1 unit19” 88.1 193.5 3 (48 VDC) 03.026.214.1 1 unit

- Temperature measuring via PTC sensorwith 2 m cable, can be plugged at the rear

- Required temperature can be set on thepotentiometer

- Fan control with 30-100% of the nominalpower, maximum rotation with temp. sensorfailure

- Individual fan monitoring- Increased cooling output with front intake- Filter mat can be changed at the front

during operation without need for tools - Uniform air distribution over the entire

width and depth of the fan unit

MaterialSheet steel

Finish / ColourEnclosure, zinc passivatedFront panel, powder-coated, smooth,RAL 7035 light-grey

ApprovalsCE Identification in accordance with lowvoltage guideline 73/23/EWG,EMC guideline 89/336/EWG

TestsVibration test in accordance with MIL-STD810 E

Supply schedule1 Fan unit1 Filter mat, Viledon P15/1501 Temperature sensor with cable, 2 m1 Signal cable, 2 m (can be plugged)1 Connection cable, 2 m with EURO plug

(115/230 VAC)1 Connection cable, 2 m without plug

(24 VDC)1 Connection cable, 2 m without plug

(48 VDC)

How suppliedAssembled, wired and tested

LUF00279_1_E

LUF00272_E

LUF00273_E

LUF00283_4_E

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 244

Page 255: Shkaf Knurr Electronics e

by knürr

245

Individual fan technical dataVoltage (V) 230 115 48 24Frequency (Hz) 50 60 - -Maximum volume current (m3/h) 117 135 170 117Power consumption (W) 14 12 5 6,5Free-flow noise level (dB(A)) 37 42 43 43Bearing system Sliding Sliding Sliding SlidingNominal rotation (1/min) 2450 2850 2900 2900Permissible envir. tempertature (°C) –20...+70 –20...+70 –20...+70 –20...+65Lifespan expectancy L10 at 40°C (hrs) 47500 52500 62500 52500

Note: All speed-controlled darts are equipped with 24 V individual fans.

THERMAL SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

19“ Filter Unit, 1 HU/UW H D kg W n Model Order no. UP Price19” 43.6 282 03.025.250.1 1 unit19” 43.6 660 03.025.253.1 1 unit

- Compatible with 19’’ vertical fan unit- Adapted to the respective chassis depth

Material / FinishEnclosure: sheet steel, painted texture,RAL 9011 blackFront panel ABS UL 94 V-0, light-grey,RAL 7035Handle, powder-coated, grey-blue,textured RAL 5008RAL 7030

Supply schedule1 Filter unit1 Filter, Filedon P 15/150

Replacement FilterW H D kg W n Model Order no. UP Price

282 03.025.246.9 1 unit660 03.025.249.9 1 unit

- For 19“ filter unit- Compatible with 19’’ vertical fan unit- Adapted to the respective chassis depth

Supply schedule1 Filter, Filedon P 15/150

dart Replacement FilterW H D kg W n Model Order no. UP Price

01.171.217.9 5 units

- For dart 19’’ fan unit, front intake, 2 HU/U

MaterialViledon P 15/150

Supply schedule1 Set of 5 units

How suppliedIn batches

LUF00205_E

LUF00280_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 245

Page 256: Shkaf Knurr Electronics e

by knürr

246

THERMAL SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

19“ Fan UnitTangential fan, 2 HU/UW H D kg W n Model Order no. UP Price19” 88.1 03.038.046.1 1 unit

03.038.109.9 1 unit

- Uniformly distributed air flow over the fullwidth

- Filter mat can be changed at the front- Mains switch and control lights at the front- Airflow monitoring signals clogged filter mat

and fan failure- Mains connection via supply terminal

Material / FinishFan enclosure, sheet steel, zinc passiva-ted, whiteFront panel, ABS UL 94 V-0, RAL 7035light-greyHandle, aluminium, powder-coated, tex-tured, RAL 5008, grey-blue

Technical dataVolume current 300 m3/hStatic pressure 70 PaNominal voltage230 VFrequency 50 HzPower consumption 35 WNominal rotation2230 min -1

Free-flow noise level, 54 dB(A)

Supply schedule1 Fan unit, 230 V/50 Hz1 Filter mat, Filedon P 15/150

Fan Mounting KitW H D For cabinet type Order no. UP Price534 miracel / B 600 / with thermostat 01.113.430.0 1 unit734 miracel / B 800 / with thermostat 01.113.431.0 1 unit534 miracel / B 600 / without thermostat 01.113.330.0 1 unit734 miracel / B 800 / without thermostat 01.113.331.0 1 unit

- For quick and straightforward forced ventilation of cabinets

- miracel / tecoras indoor- Roof installation- No loss of 19’’ installation space- Installation also easily carried out at a later

stage- Includes 2 fans (160 m3/h per fan)

Material / FinishSheet steel, 1.5 mm zinc passivated

ApprovalsCE Identification in accordance with lowvoltage guideline, 73/23/EWG, EMC guide-line 89/336/EWG

Technical data, thermostatSetting range: + 10°C ... + 60°CSwitching temperature differential (hyste-retic): 2 KContact type: 1 change-over contactSensor: thermostatic bi-metalSwitch wattage: 230 VAC/10 A (heating)

5 A (cooling)Interference suppression: in accordancewith DIN 55014

Supply schedule1 Mounting plate for fan2 Fans (160 m3/h)1 Connection cable, 2.0 m with safety

plugType 1: with thermostatType 2: without thermostatMounting material

How suppliedAssembled, wired and tested

LUF00206_E

LUF00266_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 246

Page 257: Shkaf Knurr Electronics e

TEM00040_E

by knürr

247

THERMAL SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

Ventilation UnitW H D For cabinet type Order no. UP Price

type 1 for miracel with thermo. 03.026.109.9 1 unittype 2 for miracel without thermo. 03.026.110.9 1 unit

- Compatible with all cabinet widths and depths

- For forced ventilation- With cable entry (brush strip)- Installation in roof, no loss of 19’’ installa-

tion space- Installation also easily carried out at a later

stage- Includes 3 fans (117 m3/h per fan)- Mains supply 230 V/50 Hz

Material / FinishSheet steel, 1.5 mm, zinc passivated

ApprovalsCE Identification in accordance with lowvoltage guideline 73/23/EWG, EMC guide-line 89/336/EWG

Technical data, thermostatSetting range: + 10°C ... + 60°CSwitching temperature differential (hyste-retic): 2 KContact type: 1 change-over conatctSensor: thermostatic bi-metalSwitch power: 230 VAC/10 A (heating)

5 A (cooling)Interference suppression: in accordancewith DIN 55014

Supply schedule1 Ventilation unit1 Connection cable, 2.0 m with safety plugType 1: with thermostatType 2: without thermostatMounting material

How suppliedAssembled, wired and tested

Top-Mounting FanW H D Model Order no. UP Price

type 1 with temperature sensor 05.036.000.9 1 unittype 2 without temperature sensor 05.036.001.9 1 unit

Top-mounting fans are designed for use incases in which:- No free space is available in the enclosure

or cabinet or the fan must be mountedexternally

- Hot spots occur as a result of unfavourablespace conditions, the warm air of whichmust be directly drawn off

- Extremely high air outputs are required

FinishPainted, RAL 7035, light-grey

Operating positionsHorizontal and vertical

Technical dataVolume current: 570 m3/hStatic pressure: 300 PAElectrical supply: 230 V/50 HzOutput consumption: 34 mAPower consumption: 75 WFree-flow noise level: 62 dB (A)Nominal rotation: 2150 min-1

Bearing system: ball bearingLifespan: max. 40,000 h

Supply scheduleReady wired with integrated finger protectionComplete with supply terminalType 1: with temperature sensorType 2: without temperature sensor

How suppliedFully wired

LUF00281_E

TEM00039_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 247

Page 258: Shkaf Knurr Electronics e

by knürr

248

THERMAL SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = WeightNR = Nominal rotation, NL = Noise level (free-flow), PC = Power consumption, VC = Volume current

Filter FanLxW D/d/x y/z kg max. VS El. supply. PC NL NR Ls/40º Model Order no. UP Price150x150 71/120/5 125/131 0.812 57 m3/h 230V / 50/60Hz 20 W 43 dB(A) 2650/min 40,000 h Filter fan 03.206.501.9 1 unit204x204 90/120/5.7 177/185 1 90 m3/h 230V / 50/60Hz 20 W 43 dB(A) 2650/min 40,000 h Filter fan 03.026.502.9 1 unit250x250 113/172/6 223/230 1.690 240m3/h 230V / 50/60Hz 29 W 50 dB(A) 2800/min 40,000 h Filter fan 03.026.503.9 1 unit325x325 125/208/7 291/302 3.620 520m3/h 230V / 50/60Hz 67 W 63 dB(A) 2770/min 50,000 h Filter fan 03.026.504.9 1 unit

150x150 24/5 125/131 0.140 Exit filter 03.026.511.9 1 unit204x204 20.5/5.7 177/185 0.275 Exit filter 03.026.512.9 1 unit250x250 25/6 233/230 0.440 Exit filter 03.026.513.9 1 unit325x325 26/7 291/302 0.780 Exit filter 03.026.514.9 1 unit

150x150 Replacement filter mat 03.026.521.9 6 units204x204 Replacement filter mat 03.026.522.9 6 units250x250 Replacement filter mat 03.026.523.9 6 units325x325 Replacement filter mat 03.026.524.9 6 units

- For specific use with hot spots- Compatible, can also be mounted at a later

stage, quick and straightforward- The filter mats provide high-grade filtering

out properties, can be exchanged and can bewashed out

- The fans are maintanance-free and haveparticularly long lifespans and low noiselevels

- Airflow: blown in the cabinet (pre-setting)- Can be set to either blowing or sucking

MaterialHeat-resistant ABS plastic,UL 94 V-0

ColourLight-grey RAL 7035

ApprovalsCE Identification

Protection ratingIP 54

LUF80011_E LUF80012_E

LUF800040_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 248

Page 259: Shkaf Knurr Electronics e

by knürr

249

THERMAL SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

19“ Cooling Unit 6 HU 1000 WW H D kg W Model Order no. UP Price482.6 265.9 570 45 1000 03.032.300.1 1 unit

- Service-free operation with patented con-struction without filterHigh cooling output with compact design

- CFC-Free refrigerant, R 134a- Uniform temperature distribution in the

cabinet

MaterialEnclosure, stainless steelFront panel, aluminium 3 mm

FinishFront panel, powder-coated, textured,RAL 7035, light-greyHandles, powder-coated, textured,RAL 5008, grey-blue

ApprovalsCE

Supply scheduleCooling unitMains supply cableOperating instructions

Technical dataelectrical supply valuesNominal voltage: 230 VNominal frequency: 50 HzNominal current: 4.5 AMaximum starting current: 9 APower consumption: 850 W

Power dataEffective cooling power L35L35: 1000 WVolume current, control cabinet air:

maximum 360 m3/h, speed-controlledVolume current, environmental air:

maximum 720 m3/h, speed-controlledTemperature range:

+ 20°C to + 55°CRefrigerant: R134 a (CFC-free)Protection rating: IP 44Weight: 45 kgNoise level: 70 dB (A) at 1 m spacing

with maximum air output

Output signals(micro controller functions):Required temperature and alarm tempe-rature can be set per potentiometerAlarm ouput per relay (opener and closer)Floating door contact switch as openerConnectable test mode

LUF00213_E

LUF80213_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 249

Page 260: Shkaf Knurr Electronics e

by knürr

250

THERMAL SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

Cooling Unit, Add-On and InstallationW H D kg W n Model Order no. UP Price395 980 135 39 820 03.032.302.1 1 unit395 1550 135 50 1400 03.032.304.1 1 unit

- Service-free operation with patented con-struction without filter

- Automatic condensation vaporization- For adding-on on the rear panel, rear door

or side panel of a cabinet- Lowered installation possible- No loss of 19’’ installation space- Temperature control with micro controller- CFC-Free refrigerant R 134a- No danger to electronics with dust deposits

and splash water - Uniform temperature distribution in the

cabinet

MaterialEnclosure, sheet steelFront panel, aluminium 3 mm

FinishEnclosure, powder-coated, textured,RAL 7035, light-grey

ApprovalsCE

Supply scheduleCooling unitOperating instructions

Output signals(micro controller functions):Required and alarm temperature can beset per potentiometerAlarm output per relay (opener and closer)Floating door contact switch as openerConnectable test mode

Technical data (03.032.302.1),electrical supply values(Supply via supply terminal strip):Nominal voltage: 230 VNominal frequency: 50 HzNominal current: 2.8 AMaximum starting current: 12.7 APower consumption: 660 WPower dataEffective cooling power L35L35: 820 WVolume current, control cabinet air:maximum 180 m3/h, speed-controlledVolume current, environmental air:maximum 360 m3/h, speed-controlledTemperature range:

+ 20°C to + 55°CRefrigerant: R134 a (CFC-free)Protection rating: IP 54Weight: 39 kgNoise level: 65 dB (A) at 1 m distancewith maximum air output

Technical data (03.032.302.1),electrical supply values(Supply via supply terminal strip):Nominal voltage: 230 VNominal frequency: 50 HzNominal current: 3.8 AMaximum starting current: 16 APower consumption: 720 WPower dataEffective cooling output L35L35: 1400 WVolume current, control cabinet air:

maximum 250 m3/h, speed-controlledVolume current, environmental air:

maximum 430 m3/h, speed-controlledTemperature range:

+ 20°C to + 55°CRefrigerant: R134 a (CFC-free)Protection rating: IP 54Weight: 50 kgNoise level: 65 dB (A) at 1 m distance

with maximum air output

LUF80013_E

LUF80011_1_E

LUF80012_1_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 250

Page 261: Shkaf Knurr Electronics e

by knürr

251

THERMAL SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

Cooling Unit, Top-MountingW H D kg W Model Order no. UP Price600 400 400 55 1100 03.032.310.1 1 unit

- Service-free operation with patented con-struction without filter

- Automatic condensation vaporization- For cabinet roof superstructure- No loss of 19’’ installation space- Temperature control with micro controller- CFC-Free refrigerant R 134a- No danger to electronics with dust deposits

and splash water - Uniform temperature distribution in the

cabinet

MaterialEnclosure, sheet steel

FinishEnclosure, powder-coated, textured,RAL 7035, light-grey

ApprovalsCE

Supply scheduleCooling unitOperating instructions

Technical data,electrical supply values(Supply via supply terminal strip):Nominal voltage: 230 VNominal frequency: 50 HzNominal current: 4 AMaximum starting current: 15 APower consumption: 800 WPower dataEffective cooling output L35L35: 1100 WVolume current, control cabinet air:

maximum 360 m3/h, speed-controlledVolume current, environmental air:

maximum 720 m3/h, speed-controlledTemperature range:

+ 20°C to + 55°CRefrigerant: R134 a (CFC-free)Protection rating: IP 54Weight: 55 kgNoise level: 65 dB (A) at 1 m distance

with maximum air output

Output signals(micro controller functions):Required temperature and alarm tempe-rature can be set per potentiometerAlarm ouput per relay (opener and closer)Floating door contact switch asopenerSeries-connectable test mode

Cooling Unit, Top-MountingW H D kg W Model Model no. UP Price600 446 360 47 1400 03.032.308.1 1 unit

- For cabinet roof superstructure- No loss of 19’’ installation space- Temperature control with micro controller- CFC-Free refrigerant R 134a- No danger to electronics with dust deposits

and splash water - Uniform temperature distribution in the

cabinet

MaterialEnclosure, sheet steel

FinishEnclosure, powder-coated, textured,RAL 7035, light-grey

ApprovalsCE

Supply scheduleCooling unitOperating instructions

Technical data (03.032.302.1),electrical supply values(Supply via supply terminal strip):Nominal voltage: 230 VNominal frequency: 50 HzNominal current: 5.6 AMaximum starting current: 20 APower consumption: 830 WPower dataEffective cooling output L35L35: 1400 WVolume current, control cabinet air:

maximum 510 m3/h, speed-controlledVolume current, environmental air:

maximum 640 m3/h, speed-controlledTemperature range:

+ 20°C to + 55°CRefrigerant: R134 a (CFC-free)Protection rating: IP 54Weight: 47 kgNoise level: 65 dB (A) at 1 m distance

with maximum air output

Output signalsGeneral interference signal (open collector)Excess temperature (open collector)Door contact switch (24 VDC)

LUF80014_E

LUF80015_E

LUF80017_E

LUF80016_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 251

Page 262: Shkaf Knurr Electronics e

by knürr

252

THERMAL SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

19“ Heat ExchangerW H D kg W Model Order no. UP Price443 87 405 13 1000 03.032.320.1 1 unit

- Temperature control via thermostatic regulated magnet valve

- High cooling output with low energy con-sumption and extremely compact 2 HU/Udesign

- No danger to electronics with dust depositsand splash water

- Uniform temperature distribution in thecabinet

- Service-free operation without fan

MaterialEnclosure, sheet steelFront panel, aluminium 3 mm

FinishEnclosure, powder-coated, textured,RAL 7035, light-greyFront panel, powder-coated, textured,RAL 7035, light-greyHandle, powder-coated, RAL 5008, grey-blue

ApprovalsCE

Supply scheduleHeat exchangerMains supply cableSupply plug for tubeSupply coupling for tubeCondensation tubeOperating instructions

Technical data,electrical supply values(Supply in the terminal strip)Nominal voltage: 230 VNominal frequency: 50 HzNominal current: 0.4 APower consumption: 80 WPower dataEffective cooling output, L35W10:

1000 W with 200l/h water throughputVolume current, control cabinet air:

maximum 180 m3/h, speed-controlledOperating pressure: maximum 10 barTemperature range:

+ 1°C to + 72°CRefrigerant: water, light oils or similarProtection rating: IP 44Weight: 13 kgNoise level: 52 dB (A) at 1 m distance

with maximum air output

Output signalsExcess temperature alarm

LUF00208a_E

LUF80018_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 252

Page 263: Shkaf Knurr Electronics e

by knürr

253

THERMAL SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

19“ Heat ExchangerW H D kg W Model Order no. UP Price443 175 505 16.5 2000 03.032.322.1 1 unit

- Temperature control via thermostatic regu-lated magnet valve

- High cooling output with low energy con-sumption and extremely compact 4 HU/Udesign

- No danger to electronics with dust depositsand splash water

- Uniform temperature distribution in thecabinet

- Service-free operation without fan

MaterialEnclosure, sheet steelFront panel, aluminium 3 mm

FinishEnclosure, powder-coated, textured,RAL 7035, light-greyFront panel, powder-coated, textured, RAL 7035, light-greyHandle, powder-coated, RAL 5008, grey-blue

ApprovalsCE

Supply scheduleHeat exchangerMains supply cableSupply plug for tubeSupply coupling for tubeCondensation tubeOperating instructions

Technical data,electrical supply values(Supply in the terminal strip)Nominal voltage: 230 VNominal frequency: 50 HzNominal current: 0.45 APower consumption: 100 WPower dataEffective cooling output, L35W10:

2000 W with 200l/h water throughputVolume current, control cabinet air:

maximum 360 m3/h, speed-controlledOperating pressure: maximum 10 barTemperature range:

+ 1°C to + 72°CRefrigerant: water, light oils or similarProtection rating: IP 44Weight: 16.5 kgNoise level: 52 dB (A) at 1 m distance

with maximum air output

Output signalsExcess temperature alarm

LUF00209a_E

LUF80019_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 253

Page 264: Shkaf Knurr Electronics e

by knürr

254

THERMAL SYSTEMS

LUF00211_E

LUF80020a_E

Heat Exchanger, Add-On and InstallationW H D kg W Model Order no. UP Price212 891 80 7.0 1400 03.032.326.1 1 unit

- For adding-on to the rear panel, rear dooror side panel of a cabinet

- No loss of 19“ installation space- High cooling output with low energy con-

sumption and extremely compact design- No danger to electronics with dust deposits

and splash water - Uniform temperature distribution in the

cabinet- Service-free operation without fan

MaterialEnclosure, sheet steel

FinishEnclosure, powder-coated, textured,RAL 7035, light-grey

ApprovalsCEUL

Supply scheduleHeat exchangerMains supply cableSupply plug for tubeSupply coupling for tubeCondensation tubeOperating instructions

Technical data,electrical supply values(Supply in the terminal strip)Nominal voltage: 230 VNominal frequency: 50 HzNominal current: 0.4 APower consumption: 75 WPower dataEffective cooling output, L35W10: 1400 W

with 200l/h water throughputVolume current, control cabinet air:

maximum 350 m3/h, speed-controlledOperating pressure: maximum 10 barTemperature range:

+ 1°C to + 72°CRefrigerant: water, light oils or similarProtection rating: IP 54Weight: 7.0 kgNoise level: 65 dB (A) at 1 m distance

with maximum air output

Output signalsExcess temperature alarm

LUF00211_E

LUF80060_E

Heat Exchanger, Add-On and InstallationW H D Kg W Model Order no. UP Price212 891 105 11.5 2500 03.032.328.1 1 unit

- For adding-on to the rear panel, rear dooror side panel of a cabinet

- High cooling output with low energy con-sumption and extremely compact design

- No danger to electronics with dust depositsand splash water

- Uniform temperature distribution in thecabinet

- Service-free operation without fan

MaterialEnclosure, sheet steel

FinishEnclosure, powder-coated, textured,RAL 7035, light-grey

ApprovalsCEUL

Supply scheduleHeat exchangerMains supply cableSupply plug for tubeSupply coupling for tubeCondensation tubeOperating instructions

Technical data,electrical supply values(Supply in the terminal strip)Nominal voltage: 230 VNominal frequency: 50 HzNominal current: 0.56 APower consumption: 80 WPower dataEffective cooling output, L35W10: 2500 W

with 200l/h water throughputVolume current, control cabinet air:

maximum 360 m3/h, speed-controlledOperating pressure: maximum 10 barTemperature range:

+ 1°C to + 72°CRefrigerant: water, light oils or similarProtection rating: IP 54Weight: 11.5 kgNoise level: 65 dB (A) at 1 m distance

with maximum air output

Output signalsExcess temperature alarm

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 254

Page 265: Shkaf Knurr Electronics e

by knürr

255

THERMAL SYSTEMS

LUF00251_E

Cabinet HeaterW H D kg W Model Order no. UP Price70 140 50 0.5 60 03.032.203.9 1 unit70 140 50 0.5 100 03.032.205.9 1 unit70 220 50 0.8 150 03.032.206.9 1 unit

- Cabinet air heating to prevent condensationand frost damage

- No loss of 19“ installation space- Self-regulating heating element- Compact construction- Integrated clip-on mounting for 35mm DIN

rails

NoteDoubling of the determined heating out-put with external application. Minimumspacing to heat sensitive components, 60mm.

Protection ratingIP 54

Technical dataOperating voltage 140-250 VACElectrical supply: silicone cable

2 x 0.75, length 0.5 mProtection class: IIHeating element: self-regulating resistor

(PTC)Heating element: aluminium extrusion,

anodisedMounting: clip for 35 mm DIN rail

EN 50022Mounting: verticalApprovals: VDE 0700, IEC 335-1

Supply schedule1 Cabinet heater

How suppliedAssembled, wired and tested

LUF00235_E

LUF00237c_E

Heating FanW H D kg W Model Order no. UP Price80 178 80 0.95 250 03.032.210.9 1 unit80 252 80 1.3 400 03.032.211.9 1 unit

- Cabinet air heating to prevent condensation and frost damage

- High heating output with compact design - Uniform temperature distribution in the

enclosure- Integrated clip-on mounting for 35mm

DIN rails- Safety switch off (30°C)- Note:

Minimum spacing to heat sensitive com-ponents, 60 mm.

MaterialHeating element, aluminium extrusion,anodised

Protection ratingIP 20

Technical dataOperating voltage 230 VAC/50-60 HzElectrical supply: 3-pole terminalProtection class: IHeating element: resistance heating with

integrated safety temperature guardMounting: clip for 35 mm DIN rail

EN 50022Mounting: verticalApprovals: VDE 0700, IEC 335-1

Supply schedule1 Heating fan

How suppliedAssembled, wired and tested

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 255

Page 266: Shkaf Knurr Electronics e

by knürr

256

THERMAL SYSTEMS

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

LUF00237a_E

LUF00256_E

Temperature ModuleW H D LxW kg W n Model Order no. UP Price

01.117.525.1 1 unit

- For monitoring internal cabinet temperature- Temperature display (+ 10°C ... + 70°C)- Alarm temperature setting via potentio-

meter at the front- Optical alarm display (LED red)- Alarm signaling via floating switching

contact (1 change-over contact250 VAC / 8 A)

- Power supply 230 V / 50 Hz

MaterialPlastic

ApprovalsCE Identification in accordance with lowvoltage guideline 73/23/EWG, EMC guide-line 89/336/EWG

Supply schedule1 Temperature module1 Temperature sensor (3 m)

How suppliedAssembled, wired and tested

19“ Front Panel 1 HU / U for Temperature ModuleW H D LxW kg W n Model Order no. UP Price

01.117.526.1 1 unit

- For installation of the temperature module

Material / FinishSheet steel, 1.5 mm powder-coated.

ColourRAL 7035 light-grey

Supply schedule1 19’’ Front panel

Mounting for Temperature ModuleW H D LxW kg W n Model Order no. UP Price

01.117.527.0 1 unit

- For non-standard installation of the tempe-rature module, e.g. on the side on the 19’’extrusion

Material / FinishAluminium 2 mm, polished

Supply schedule1 MountingMounting material

How suppliedFlat-packed kit

LUF00255_E

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 256

Page 267: Shkaf Knurr Electronics e

by knürr

257

THERMAL SYSTEMS

LUF20000_E

LUF00219_E

ThermostatW H D LxW kg W n Model Order no. UP Price

01.113.384.3 1 unit

- For controlling internal cabinet temperaturein conjunction with fan units and heatingfans

- Setting range: + 10°C ... + 60°C- Switching temperature differential

(hysteretic) 2 K- Contact type: 1 change-over contact- Sensor: thermostatic bi-metal- Switching capacity: 230 VAC/10 A (heating),

5 A (cooling)- Intereference suppression: in accordance

with DIN 55014

MaterialPlastic

Protection ratingIP 30

ApprovalsCE Identification in accordance with lowvoltage guideline 73/23/EWG, EMC guideline 89/336/EWG

Dimensions74 x 74 x 23 mm

Supply schedule1 Thermostat1 Mounting bracketMounting material

HygrostatW H D LxW kg W n Model Order no. UP Price

03.032.215.9 1 unit

- For preventing condensation and componentcorrosion

- Switches heating on when set humidity levelis exceeded

- Can be mounted at any position- Integrated clip-on mounting for 35 mm DIN

rail

MaterialEnclosure, plastic UL 94V-0

Protection ratingIP 20

Weight60 g

Technical dataMeasuring range: 50 ... 100 % rFMeasuring accuracy: +/- 3 % rFSwitching hysteresis: 4 % rFSwitching contact: type, change-overcontactMaximum load rating: ohmic load 5 A /

230 VAC, inductive load (cosj = 0.8) 0.2 A to 230 VAC, inductive load (L/R = 3 mS) 1 A to 50 VDC, 0.5 A to 75 VDC

Minimum load rating: 100 mA, 20 VDC/ACInterference suppression (VDE 0875): NEnvironmental temperature, 20 ... 60°CInstallation position: freely-selectableElectrical supply: 3-pole terminal

Supply schedule1 Hygrostat

Dimensiosn in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weightn = Number of fans, W = Effective cooling output

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 257

Page 268: Shkaf Knurr Electronics e

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 258

Page 269: Shkaf Knurr Electronics e

Product Compact cabinet lamps Page 260Earthing bars Page 261

Electrical Accessories

Product Front panels Page 262Internal shelves, drawers Page 265Chassis runners, telescopic slides Page 273Cable management Page 277Mounting material Page 284

Mechanical Accessories

ACCESSORIES

by knürr

259

SYSTEM ACCESSORIES

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 259

Page 270: Shkaf Knurr Electronics e

by knürr

260

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = DepthHU/U = Standard height unit (Unit), UP = Unit of packaging,

Cable Junction BoxW H D HU/U h d w Model Order no. UP Price

00.078.720.9 1 unit

ELM00033_E

- For on-site 230 V electro-installation - As fixed location exchange point - Simple and quick mounting- Complete with mounting material

Supply schedule1 Cable junction box1 Mounting bracketMounting material

Modular Terminal BoxW H D HU/U h d w Model Order no. UP Price

01.117.521.9 1 unit

ELM00128_E

- For on-site 230 V electro-installation - With modular terminal 8 x 42

- Lead-ins, M20 (circumferential seal, 8–13.5 mm)

- IP 54

MaterialImpact and flame-resistant Polystyrol

Supply schedule1 Series terminal box4 Mounting supports

Compact Cabinet LampW H D HU/U h d w Model Order no. UP Price65 65 365 01.131.465.9 1 unit

ELM00135_E

FeaturesWith magnet mountingEnergy-effective lampSafety socketOn / Off switchPower supply lead 3 mWith cover

ApprovalVDE ICE

Protection rating IP20

Technical data- Operating voltage

230 V / 50-60 Hz- Light material

Compact fluorescent lamp withintegrated starter

- Power consumption11 W = 75 W filament lamp

- Light intensity900 Lm

- Interference suppressionin accordance with VDE 0712, IEC 82

- Socket230 VAC / 16A

- Connections3-pole screw terminal, 2.5 mm2 with strain relief

226-288_eng_final.qxd 07.08.2002 16:01 Uhr Seite 260

Page 271: Shkaf Knurr Electronics e

by knürr

261

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = DepthHU/U = Standard height unit (Unit), UP = Unit of packaging

Door Contact Switch W H S HU/U h d w Model Order no. UP Price

01.110.722.9 1 unit

ELM00137_E

- On / Off switch, 4 A, 230 V ~- Activation with door opening and closing

Supply schedule1 Door contact switch (not wired)1 Mounting bracketMounting material

Equipotential Bonding BarW H S HU/U h d w Model Order no. UP Price

01.117.524.3 1 unit

ELM00114_E

- For central earthing of all protective conductors

- With sealing cover- Connection options:- 1 x Round conductor 8-10 mm Ø- 1 x Flat band up to 30 mm wide or round

conductor 8-10 mm Ø- 7 x one or several wire conductors up to 16

mm2 or fine-wired conductor up to 10 mm2

MaterialBase plate and cover, impact-resistantplastic Contact strip, brass, nickel-plated

Supply schedule1 Equipotential bonding bar

Earthing BarW H S HU/U h d w Model Order no. UP Price

24 for doubleprorack 01.240.546.9 1 unit21 for doubleprorack 01.240.545.9 1 unit18 for doubleprorack 01.240.544.9 1 unit15 for doubleprorack 01.240.543.9 1 unit45 for miracel 01.110.709.9 1 unit41 for miracel 01.110.708.9 1 unit12 for miracel 01.110.703.9 1 unit

ELM200117_E

- For safe earthing and equipotential bondingof equipment and built-in units

MaterialElectrolyt copper

Supply schedule1 Earthing bar2 BracketsMounting material

Contact ClampW H S HU/U h d w Model Order no. UP Price

01.110.715.9 20 units

DOP20016_E

- For safe connection of equipment and built-in units with the earthing bar

Supply schedule20 Contact clamps

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 261

Page 272: Shkaf Knurr Electronics e

by knürr

262

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19” Front PanelAluminium 3 mmH X Y HU/U Model Order no. UP Price

46.3 31.7 1 polished 02.008.021.0 1 unit88.1 76.2 2 polished 02.008.022.0 1 unit

132.5 57.1 3 polished 02.008.023.0 1 unit177.0 101.6 4 polished 02.008.024.0 1 unit221.4 146.0 5 polished 02.008.025.1 1 unit265.9 76.2 190.4 6 polished 02.008.026.0 1 unit310.3 57.1 234.9 7 polished 02.008.027.0 1 unit354.8 76.2 279.4 8 polished 02.008.028.0 1 unit399.2 120.6 323.6 9 polished 02.008.029.0 1 unit443.8 165.1 368.3 10 polished 02.008.030.0 1 unit488.1 146.1 412.7 11 polished 02.008.031.0 1 unit532.6 190.5 457.1 12 polished 02.008.032.0 1 unit

46.3 31.7 1 powder-coated 02.008.021.1 1 unit88.1 76.2 2 powder-coated 02.008.022.1 1 unit

132.5 57.1 3 powder-coated 02.008.023.1 1 unit177.0 101.6 4 powder-coated 02.008.024.1 1 unit221.4 146.0 5 powder-coated 02.008.025.1 1 unit265.9 76.2 190.4 6 powder-coated 02.008.026.1 1 unit

46.3 31.7 1 anodised 02.008.071.6 1 unit88.1 76.2 2 anodised 02.008.072.6 1 unit

132.5 57.1 3 anodised 02.008.073.6 1 unit177.0 101.6 4 anodised 02.008.074.6 1 unit221.4 146.0 5 anodised 02.008.075.6 1 unit265.9 76.2 190.4 6 anodised 02.008.076.6 1 unit310.3 57.1 234.9 7 anodised 02.008.077.6 1 unit354.8 76.2 279.4 8 anodised 02.008.078.6 1 unit399.2 120.6 323.6 9 anodised 02.008.079.6 1 unit443.8 165.1 368.3 10 anodised 02.008.080.6 1 unit488.1 146.1 412.7 11 anodised 02.008.081.6 1 unit532.6 190.5 457.1 12 anodised 02.008.082.6 1 unit

Material / FinishFinal digit of order number .0:AlMg3 - F23 polished with protective filmFinal digit of order number .1:AlMg3 - F23, powder-coated, RAL 7035Final digit of order number .6:AlMg3 - F23 EB (eloxal-capable), anodisedE6/EV1

Supply schedule1 19” Front panel

FRO000005_E

MEC00028_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 262

Page 273: Shkaf Knurr Electronics e

by knürr

263

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19” Blanking PanelW H D HU/U Model Order no. UP Price482.6 43.6 1 powder-coated 01.117.026.1 1 unit482.6 88.1 2 powder-coated 01.117.028.1 1 unit482.6 132.5 3 powder-coated 01.117.029.1 1 unit482.6 265.9 6 powder-coated 01.117.030.1 1 unit482.6 399.2 9 powder-coated 01.117.031.1 1 unit

- For covering open-fronted surface spaces

MaterialSheet steel 1.5 mm

FinishPowder-coated, light-greyRAL 7035, textured

Supply schedule1 19” Blanking panel

CUD00005_E

CUD00004_E

19” Ventilation Front PanelH X Y HU/U Model Order no. UP Price

43.6 31.7 1 powder-coated 02.008.101.1 1 unit88.1 76.2 2 powder-coated 02.008.102.1 1 unit

132.5 57.1 3 powder-coated 02.008.103.1 1 unit177.0 101.6 4 powder-coated 02.008.104.1 1 unit221.4 146.0 5 powder-coated 02.008.105.1 1 unit265.9 190.4 76.2 6 powder-coated 02.008.106.1 1 unit

43.6 31.7 1 anodised 02.008.101.6 1 unit88.1 76.2 2 anodised 02.008.102.6 1 unit

132.5 57.1 3 anodised 02.008.103.6 1 unit177.0 101.6 4 anodised 02.008.104.6 1 unit221.4 146.0 5 anodised 02.008.105.6 1 unit265.9 190.4 76.2 6 anodised 02.008.106.6 1 unit

- For additional ventilation for 19” cabinets and 19“ pedestals in accordance with IEC 297

MaterialAluminium

FinishFinal digit of order number .1:Powder-coated, textured, light-grey RAL 7035Final digit of order number .6:Colourless anodised

Supply schedule1 Ventilation front panel

LUF00217_E

MEC00027_E

19” Front PanelHingedW H D HU/U Model Order no. UP Price

3 anodised 01.110.780.6 1 unit6 anodised 01.110.781.6 1 unit

- With 19” adapter and hinge

MaterialAluminium 4 mm

FinishAnodised

Supply schedule1 Front panel, hinged1 19” Adapter1 HingeFRO00007_E

FRO00006_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 263

Page 274: Shkaf Knurr Electronics e

by knürr

264

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19” Front Ventilation PanelW H D HU/U Model Order no. UP Price483 43.6 1 02.008.111.1 1 unit483 88.1 2 02.008.112.1 1 unit483 132.5 3 02.008.113.1 1 unit

- For additional ventilation for 19”cabinetsand 19” pedestals in accordance with IEC297

MaterialABS (UL 94 V-0), light-grey RAL 7035

Supply scedule1 Front ventilation panel

Panel FilterFor 19" front ventilation panelW H D HU/U Model Order no. UP Price

1 02.008.131.9 1 unit2 02.008.132.9 1 unit3 02.008.133.9 1 unit

MaterialFilter fibres and screen cloth

Supply schedule1 Panel filterMounting material

19" Blanking Front PanelW H D HU/U Model Order no. UP Price483 43.6 1 02.008.121.1 1 unit483 88.1 2 02.008.122.1 1 unit

Material / ColourABS (UL 95 V-0), light-grey RAL 7035

Supply schedule1 Blanking front panel

LUF00218_E

LUF00093_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 264

Page 275: Shkaf Knurr Electronics e

by knürr

265

SYSTEM ACCESSORIES

Dimensiosn in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19” ShelfFixedW H D HU/U d W x L For cabinet type Order no. UP Price19” 600 365 430 x 300 miracel/smaract LAN 01.102.001.1 1 unit19” 600 440 430 x 300 miracel/smaract 19” 01.102.002.1 1 unit19” 800 565 430 x 500 miracel/smaract LAN 01.102.003.1 1 unit19” 800 640 430 x 600 miracel/smaract 19” 01.102.004.1 1 unit19” 900 665 430 x 600 miracel/smaract LAN 01.102.004.1 1 unit19” 900 740 430 X 600 miracel/smaract 19”server 01.102.005.1 1 unit

600 600 530 515 x 500 miracel LW 535 01.102.200.1 1 unit700 600 530 615 x 500 miracel LW 635 01.102.201.1 1 unit800 600 530 715 x 500 miracel LW 735 01.102.202.1 1 unit600 800 730 515 x 700 miracel LW 535 01.102.208.1 1 unit700 800 730 615 x 700 miracel LW 635 01.102.209.1 1 unit800 800 730 715 x 700 miracel LW 735 01.102.210.1 1 unit600 900 830 515 x 800 miracel LW 535 01.102.212.1 1 unit800 900 830 715 x 800 miracel LW 735 01.102.214.1 1 unit

600 600 535 515 x 500 smaract LW 535 01.102.252.1 1 unit600 800 735 515 x 700 smaract LW 535 01.102.254.1 1 unit600 900 835 515 x 800 smaract LW 535 01.102.255.1 1 unit

19” 500 335 430 x 300 doubleprorack LAN 01.102.001.1 1 unit19” 500 460 430 x 300 doubleprorack 19” or door 01.102.002.1 1 unit19” 600 435 430 x 300 doubleprorack LAN 01.102.002.1 1 unit19” 600 485 430 x 300 doubleprorack 19” IP54 01.102.002.1 1 unit19” 600 560 430 x 500 doubleprorack 19” or door 01.102.003.1 1 unit19” 700 660 430 x 600 doubleprorack 19” or door 01.102.004.1 1 unit19” 800 635 430 x 600 doubleproack LAN 01.102.004.1 1 unit19” 800 685 430 x 600 doubleprorack 19” IP 54 01.102.004.1 1 unit

19” 500 285 430 x 200 conact 01.102.000.1 1 unit19” 600 385 430 x 300 conact 01.102.001.1 1 unit

- With perforation for optimal air supply

Material / FinishSheet steel 1.0 mm, zinc passivated, powder-coated, textured

ColourRAL 7035 light-grey

Load rating500 N Static per unit

Supply schedule2 Mounting rails includes mountingbracket1 Shelf board 1 Extension board (from L = 600)Mounting material

How suppliedFlat-packed kit

MEC00451_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 265

Page 276: Shkaf Knurr Electronics e

by knürr

266

19” ShelfFull pull-outW H D HU/U d W x L For cabinet type Order no. UP Price19” 600 365 430 x 300 miracel/smaract LAN 01.102.160.1 1 unit19” 600 440 430 x 300 miracel/smaract 19” 01.102.160.1 1 unit19” 800 565 430 x 500 miracel/smaract LAN 01.102.161.1 1 unit19” 800 640 430 x 500 miracel/smaract 19” 01.102.161.1 1 unit19” 900 665 430 x 500 miracel/smaract LAN 01.102.161.1 1 unit19” 900 740 430 x 600 miracel/smaract 19”server 01.102.162.1 1 unit

- With perforation for optimal airflow

Material / FinishSheet steel 1.0 mm, zinc passivated,powder-coated, textured

ColourRAL 7035 light-grey

Load rating500 N Static per unit

Supply schedule1 Pair of telescopic slides1 Shelf board 1 Extension board (from L = 600)Mounting material

How suppliedFlat-packed kit

MEC00462_E

SYSTEM ACCESSORIES

Dimensiosn in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19” ShelfPartial pull-outW H D HU/U d W x L For cabinet type Order no. UP Price19” 600 365 430 x 300 miracel/smaract LAN 01.102.010.1 1 unit19” 600 440 430 x 300 miracel/smaract 19” 01.102.010.1 1 unit19” 800 565 430 x 500 miracel/smaract LAN 01.102.011.1 1 unit19” 800 640 430 x 500 miracel/smaract 19” 01.102.011.1 1 unit19” 900 665 430 x 500 miracel/smaract LAN 01.102.011.1 1 unit19” 900 740 430 x 600 miracel/smaract 19” server 01.102.012.1 1 unit

600 600 530 515 x 500 miracel LW 535 01.102.170.1 1 unit700 600 530 615 x 500 miracel LW 635 01.102.171.1 1 unit800 600 530 715 x 500 miracel LW 735 01.102.172.1 1 unit600 800 730 515 x 600 miracel LW 535 01.102.178.1 1 unit700 800 730 615 x 600 miracel LW 635 01.102.179.1 1 unit800 800 730 715 x 600 miracel LW 735 01.102.180.1 1 unit

19” 500 460 430 x 300 doubleprorack 19” or door 01.102.010.1 1 unit19” 600 435 430 x 300 doubleprorack LAN 01.102.010.1 1 unit19” 600 560 430 x 500 doubleprorack 19” or door 01.102.011.1 1 unit19” 700 660 430 x 500 doubleprorack 19” or door 01.102.011.1 1 unit19” 800 635 430 x 500 doubleprorack LAN 01.102.011.1 1 unit

19” 600 385 430 x 300 conact 01.102.010.1 1 unit

- With perforation for optimal airflow

Material / FinishSheet steel 1.0 mm, zinc passivated, powder-coated, textured

ColourRAL 7035 light-grey

Load rating500 N Static per unit

Supply schedule1 Pair of telescopic slides1 Shelf board 1 Extension board (from L = 600)Mounting material

How suppliedFlat-packed kit

MEC00452_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 266

Page 277: Shkaf Knurr Electronics e

by knürr

267

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19” Heavy Duty ShelfFixedW H D HU/U d WxL For cabinet type Order no. UP Price19” 800 565 467 x 460 miracel/smaract LAN 01.131.473.1 1 unit19” 800 640 467 x 460 miracel/smaract 19” 01.131.475.1 1 unit19” 900 665 467 x 560 miracel/smaract LAN 01.131.476.1 1 unit19” 900 740 467 x 560 miracel 19”server 01.131.474.1 1 unit

600 800 730 534 x 536 miracel LW 535 01.131.477.1 1 unit800 800 730 734 x 536 miracel LW 735 01.131.479.1 1 unit600 900 830 534 x 536 miracel LW 535 01.131.481.1 1 unit800 900 830 734 x 536 miracel LW 735 01.131.483.1 1 unit

- Surface with perforations

Material / FinishSheet steel 1.0 mm, zinc passivated, powder-coated, textured

ColourRAL 7035 light-grey

Load rating1000 N Static per unit

Supply schedule1 Fixed internal shelf, can be screwedMounting material

How suppliedFlat-packed kit

MEC00120_E

ZUB80001_E

19” Heavy Duty ShelfFull pull-outW H D HU/U d WxL For cabinet type Order no. UP Price19” 600 365 412 x 360 miracel/smaract LAN 01.102.030.1 1 unit19” 600 440 412 x 360 miracel/smaract 19” 01.102.030.1 1 unit19” 800 565 412 x 560 miracel/smaract LAN 01.102.031.1. 1 unit19” 800 640 412 x 560 miracel/smaract 19” 01.102.031.1 1 unit19” 900 665 412 x 660 miracel/smaract LAN 01.102.032.1 1 unit19” 900 740 412 x 660 miracel/scmaract 19” server 01.102.032.1 1 unit

600 800 730 478 x 660 miracel LW 535 01.102.034.1 1 unit800 800 730 678 x 660 miracel LW 735 01.102.037.1 1 unit600 900 830 478 x 660 miracel LW 535 01.102.035.1 1 unit800 900 830 678 x 660 miracel LW 735 01.102.038.1 1 unit

600 800 735 478 x 660 smaract LW 535 01.102.034.1 1 unit600 900 835 478 x 660 smaract LW 535 01.102.035.1 1 unit

- WIth perforations for optimal air supply- Locking when in closed and fully extended

positions- Easy mounting with patented quick moun-

ting system

Material / FinishSheet steel 1.5 mm, powder-coated, tex-tured

ColourRAL 7035 light-grey

Load rating

1200 N Static Supply schedule1 Pair of telescopic slides1 Shelf boardMounting material

How suppliedFlat-packed kit

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 267

Page 278: Shkaf Knurr Electronics e

by knürr

268

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19” Drawer with LockMounting on 19” installation front and rearW H D HU/U d L For cabinet type Order no. UP Price

19” 43.6 600 1 365 400 miracel/smaract LAN 02.045.151.1 1 unit

19” 43.6 600 1 440 400 miracel/smaract 19” 02.045.151.1 1 unit19” 87.1 600 2 440 400 miracel/smaract 19” 02.045.152.1 1 unit19” 131.5 600 3 440 400 miracel/smaract 19” 02.045.153.1 1 unit19” 176.0 600 4 440 400 miracel/smaract 19” 02.045.154.1 1 unit

19” 43.6 800 1 565 400 miracel/smaract LAN 02.045.151.1 1 unit19” 87.1 800 2 565 400 miracel/smaract LAN 02.045.152.1 1 unit19” 131.5 800 3 565 400 miracel/smaract LAN 02.045.153.1 1 unit19” 176.0 800 4 565 400 miracel/smaract LAN 02.045.154.1 1 unit

19” 43.6 800 1 640 600 miracel/smaract 19” 02.045.161.1 1 unit

19” 43.6 900 1 665 600 miracel/smaract LAN 02.045.161.1 1 unit19” 87.1 900 2 665 600 miracel/smaract LAN 02.045.162.1 1 unit19” 131.5 900 3 665 600 miracel/smaract LAN 02.045.163.1 1 unit19” 176.0 900 4 665 600 miracel/smaract LAN 02.045.164.1 1 unit

19” 43.6 900 1 740 600 miracel/smaract 19” server 02.045.161.1 1 unit19” 87.1 900 2 740 600 miracel/smaract 19” server 02.045.162.1 1 unit19” 131.5 900 3 740 600 miracel/smaract 19” server 02.045.163.1 1 unit19” 176.0 900 4 740 600 miracel/smaract 19” server 02.045.164.1 1 unit

19” 43.6 500 1 460 400 doubleprorack 19”or door 02.045.151.1 1 unit19” 87.1 500 2 460 400 doubleprorack 19” or door 02.045.152.1 1 unit19” 131.5 500 3 460 400 doubleprorack 19” or door 02.045.153.1 1 unit19” 176.0 500 4 460 400 doubleprorack 19” or door 02.045.154.1 1 unit

19” 43.6 600 1 435 400 doubleprorack LAN 02.045.151.1 1 unit19” 87.1 600 2 435 400 doubleprorack LAN 02.045.152.1 1 unit19” 131.5 600 3 435 400 doubleprorack LAN 02.045.153.1 1 unit19” 176.0 600 4 435 400 doubleprorack LAN 02.045.154.1 1 unit

19” 43.6 600 1 485 400 doubleprorack 19” IP54 02.045.151.1 1 unit19” 87.1 600 2 485 400 doubleprorack 19” IP54 02.045.152.1 1 unit19” 131.5 600 3 485 400 doubleprorack 19” IP54 02.045.153.1 1 unit19” 176.0 600 4 485 400 doubleprorack 19” IP54 02.045.154.1 1 unit

19” 43.6 600 1 560 400 doubleprorack 19” or door 02.045.151.1 1 unit19” 87.1 600 2 560 400 doubleprorack 19” or door 02.045.152.1 1 unit19” 131.5 600 3 560 400 doubleprorack 19” or door 02.045.153.1 1 unit19” 176.0 600 4 560 400 doubleprorack 19” or door 02.045.154.1 1 unit

19” 43.6 700 1 660 600 doubleprorack 19” or door 02.045.161.1 1 unit19” 87.1 700 2 660 600 doubleprorack 19” or door 02.045.162.1 1 unit19” 131.5 700 3 660 600 doubleprorack 19” or door 02.045.163.1 1 unit19” 176.0 700 4 660 600 doubleprorack 19” or door 02.045.164.1 1 unit

19” 43.6 800 1 635 600 doubleprorack LAN 02.045.161.1 1 unit19” 87.1 800 2 635 600 doubleprorack LAN 02.045.162.1 1 unit19” 131.5 800 3 635 600 doubleprorack LAN 02.045.163.1 1 unit19” 176.0 800 4 635 600 doubleprorack LAN 02.045.164.1 1 unit

19” 43.6 800 1 685 600 doubleprorack 19” IP54 02.045.161.1 1 unit19” 87.1 800 2 685 600 doubleprorack 19” IP54 02.045.162.1 1 unit19” 131.5 800 3 685 600 doubleprorack 19” IP54 02.045.163.1 1 unit19” 176.0 800 4 685 600 doubleprorack 19” IP54 02.045.164.1 1 unit

- For mounting in cabinets with fixed 19”installation front and rear

- Full pull-out

Material / FinishDrawer, sheet steel, 1.0 mm,powder-coated, texturedTelescopic rails, steel, cold rolled,sendizimir zinc passivated

ColourDrawer, RAL 7035 light-grey

Load rating1 HU/U - 200 N static2 HU/U - 400 N static3 HU/U - 400 N static4 HU/U - 400 N static

Supply schedule1 19” Drawer with lock, includes key1 Pair of telescopic slidesMounting material

How suppliedPre-assembled

SCH00057_E

SCH00053_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 268

Page 279: Shkaf Knurr Electronics e

by knürr

269

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19” Drawer Front-side installationW H D HU/U d L For cabinet type Order no. UP Price19” 43.6 600-900 1 miracel/smaract/doubleprorack/conact 01.113,926.1 1 unit19” 88.1 600-900 2 miracel/smaract/doubleprorack/conact 01.113.927.1 1 unit19” 132.5 600-900 3 miracel/smaract/doubleprorack/conact 01.113.928.1 1 unit

- Front installation on the front-side 19”extrusions

- For storing service documents- Quick and easy mounting

Material / FinishDrawer, sheet steel, 1.0 mm,powder-coated, texturedTelescopic rails, sendizimir zinc passivated

ColourDrawer, RAL 7035 light-grey

Load rating150 N Static

Supply schedule1 19" Drawer with lock,

includes key1 Pair of telescopic slidesMounting material

How suppliedPre-assembled

SCH00058_E

SCH00054_E

Writing BoardFor 19” drawer with lockW H D HU/U d L For cabinet type Order no. UP Price

400 02.045.202.9 1 unit600 02.045.203.9 1 unit

- For drawer depths 400 and 600 mm

Material/FinishSheet steel, 1.0 mm, powder-coated, textured

ColourRAL 7035 light-grey

Supply schedule1 Writing boardMounting material

How suppliedFlat-packed kit

SCH00062_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 269

Page 280: Shkaf Knurr Electronics e

by knürr

270

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19” Keyboard Drawer 1 HU/UWithout PC mouse extensionW H D HU/U d L For cabinet type Order no. UP Price

19” 43.6 800/900 1 miracel/smaract 01.136.378.1 1 unit

- With hand rest

Material / FinishSheet steel, 1.25 mmHand rest, sponge rubber

Dimensions- Useful storage surface:

Dimensions without hand rest W 372 mm x D 209 mm x H 32 mm

Finish / ColourPowder-coated, textured RAL 7035Light-grey

Supply schedule1 Keyboard drawer1 Pair of telescopic slides1 Hand rest Mounting material

How suppliedFlat-packed kit

NNootteeKeyboard not part of the supply scheduleNot for cabinet depth, D 600

MEC00109_E

19” Keyboard Drawer 1 HU/UWith PC mouse extensionW H D HU/U d L For cabinet type Order no. UP Price

19” 43.6 800/900 1 miracel/smaract 01.136.379.1 1 unit

- With hand rest- Mouse board can be optionally pulled out on

the right or left - Storage section for PC mouse

Dimensions- Useful storage surface:

Dimensions without hand rest W 372 mm x D 209 mm x H 32 mm

Finish / ColourPowder-coated, textured RAL 7035Light-grey

Supply schedule1 Keyboard drawer1 Pair of telescopic slides1 Hand rest Mounting material

How suppliedFlat-packed kit

NNootteeKeyboard not part of the supply scheduleNot for cabinet depth, D 600

MEC00116_E

19” Keyboard Drawer 1 HU/UFor touchpad keyboardW H D HU/U d L For cabinet type Order no. UP Price19” 43.6 800/900 1 miracel/smaract 01.136.380.1 1 unit

- With hand rest

Dimensions- Useful storage surface:

Dimensions without hand rest W 418 mm x D 263 mm x H 32 mm

Finish / ColourPowder-coated, textured RAL 7035Light-grey

Supply schedule1 Keyboard drawer1 Pair of telescopic slides1 Hand rest Mounting material

How suppliedFlat-packed kit

NNootteeKeyboard not part of the supply scheduleNot for cabinet depth, D 600

MEC00107_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 270

Page 281: Shkaf Knurr Electronics e

by knürr

271

SYSTEM ACCESSORIES

Dimensiosn in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19" Keyboard Drawer 1 HU/UFor 19” keyboardW H D HU/U d L For cabinet type Order no. UP Price19” 43.6 600 1 440 miracel/smaract 19” 02.011.101.1 1 unit19” 43.6 800 1 565 miracel/smaract LAN 02.011.101.1 1 unit19” 43.6 800 1 640 miracel/smaract 19” 02.011.101.1 1 unit19” 43.6 900 1 665 miracel/smaract LAN 02.011.101.1 1 unit19” 43.6 900 1 740 miracel/smaract 19” server 02.011.101.1 1 unit

19” 43.6 500 1 460 doubleprorack 19” or door 02.011.101.1 1 unit19” 43.6 600 1 435 doubleprorack LAN 02.011.101.1 1 unit19” 43.6 600 1 485 doubleprorack IPS 3 02.011.101.1 1 unit19” 43.6 600 1 560 doubleprorack 19” or door 02.011.101.1 1 unit19” 43.6 700 1 660 doubleprorack 19” or door 02.011.101.1 1 unit19” 43.6 800 1 635 doubleprorack LAN 02.011.101.1 1 unit19” 43.6 800 1 685 doubleprorack 19” or door 02.011.101.1 1 unit

- With hand rest- With cable strain relief

MaterialMain unit, sheet steel, 1.0 mm,Front panel, sheet steel, 1.0 mm

Finish / ColourPowder-coated, textured, RAL 7035 light-grey

Supply schedule1 19” Keyboard drawer, 1 U1 Pair of telescopic slidesVelcro strip for fixing keyboardMounting material

How suppliedPre-assembled

SCH00059_E

SCH00055_E

19" Internal Shelf 1 HU/UPull-outW H D HU/U d L For cabinet type Order no. UP Price19” 43.6 600 1 365 403 x 400 miracel/smaract LAN 02.045.149.1 1 unit19” 43.6 600 1 440 403 x 400 miracel/smaract 19” 02.045.149.1 1 unit19” 43.6 800 1 565 403 x 600 miracel/smaract LAN 02.045.147.1 1 unit19” 43.6 800 1 640 403 x 600 miracel/smaract 19” 02.045.147.1 1 unit19” 43.6 900 1 665 403 x 600 miracel/smaract LAN 02.045.147.1 1 unit19” 43.6 900 1 740 403 x 600 miracel/smaract 19” 02.045.147.1 1 unit

19” 43.6 500 1 460 403 x 400 doubleprorack 19” or door 02.045.149.1 1 unit19” 43.6 600 1 435 403 x 400 doubleprorack LAN 02.045.149.1 1 unit19” 43.6 600 1 485 403 x 400 doubleprorack 19” IP54 02.045.149.1 1 unit19” 43.6 600 1 560 403 x 400 doubleprorack 19” or door 02.045.149.1 1 unit19” 43.6 700 1 660 403 x 600 miracel/smaract 19” 02.045.147.1 1 unit19” 43.6 800 1 635 403 x 600 doubleprorack LAN 02.045.147.1 1 unit19” 43.6 800 1 685 403 x 600 doubleprorack 19” IP54 02.045.147.1 1 unit

- With handle- Can also be used as writing board

Material / FinishShelf, sheet steel, 1.0 mmTelescopic rails, cold rolled steel

Finish / ColourPowder-coated, texturedRAL 7035 light-grey

Load rating200 N Static

Supply schedule1 Shelf1 Pair of telescopic slidesMounting material

How supplied Pre-assembled

MEC00118_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 271

Page 282: Shkaf Knurr Electronics e

by knürr

272

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19” Shelf, 2 HU/UFixedW H D W x L For cabinet type Order no. UP Price19” 88.1 600/800/900 432 x 280 miracel/smaract 01.113.736.1 1 unit19” 88.1 600/800/900 432 x 380 miracel/smaract 01.113.737.1 1 unit19” 88.1 500/600/700/800 432 x 280 doubleprorack 01.113.736.1 1 unit19” 88.1 500/600/700/800 432 x 380 doubleprorack 01.113.737.1 1 unit19” 88.1 400/500/600 432 x 280 conact 01.113.736.1 1 unit19” 88.1 500/600 432 x 380 conact 01.113.737.1 1 unit

- For mounting in cabinets with fixed 19" installation, front

- Quick and easy mounting on the 19” extrusions

- Also for swing frames in 19" cabinet and19” enclosure

Finish / ColourPowder-coated, textured RAL 7035Light-grey

MaterialSheet steel, 1.5 mm

Load rating200 N Static

Supply schedule1 Shelf, fixedMounting material

How suppliedFlat-packed kit

MIR00373_E

MIR00375_E

19” Shelf, 2 HU/UAdjustableW H D W x L For cabinet type Order no. UP Price19” 88.1 600/800/900 432 x 280 miracel/smaract 01.113.409.1 1 unit19” 88.1 600/800/900 432 x 380 miracel/smaract 01.113.410.1 1 unit19” 88.1 600/800/900 432 x 480 miracel/smaract 01.113.411.1 1 unit19” 88.1 500/600/700/800 432 x 280 doubleprorack 01.113.409.1 1 unit19” 88.1 500/600/700/800 432 x 380 doubleprorack 01.113.410.1 1 unit19” 88.1 600/700/800 432 x 480 doubleprorack 01.113.411.1 1 unit19” 88.1 400/500/600 432 x 280 conact 01.113.409.1 1 unit19” 88.1 500/600 432 x 380 conact 01.113.410.1 1 unit19” 88.1 600 432 x 480 conact 01.113.411.1 1 unit

- For mounting in cabinets with adjustable 19" installation, front

- Quick and easy mounting on the 19” extrusions

- Also for swing frames in 19" cabinet and19” enclosure

- Depth adjustable at increments of 25 mm

Material / FinishSheet steel, 1.5 mm, powder-coated,textured

ColourRAL 7035 light-grey

Load rating200 N Static

How suppliedFlat-packed kit

MIR00102_E

MIR00103_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 272

Page 283: Shkaf Knurr Electronics e

by knürr

273

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

Universal Chassis RunnerScrew fittingW H D HU/U d L For cabinet type Order no. UP Price

600 365 312 miracel/smaract LAN 02.310.258.9 1 pair600 440 412 miracel/smaract 19” 02.310.259.9 1 pair800 565 512 miracel/smaract LAN 02.310.260.9 1 pair800 640 612 miracel/smaract 19” 02.310.261.9 1 pair900 665 612 miracel/smaract LAN 02.310.261.9 1 pair900 740 712 miracel/smaract 19” server 02.310.262.9 1 pair

500 460 412 doubleprorack 19” or door 02.310.259.9 1 pair600 435 412 doubleprorack LAN 02.310.259.9 1 pair600 560 512 doubleprorack 19” or door 02.310.260.9 1 pair800 635 512 doubleprorack LAN 02.310.260.9 1 pair800 660 612 doubleprorack 19” or door 02.310.261.9 1 pair

- For installation in 19" cabinet and enclosure

FinishZinc passivated, yelow chrome-plated

MaterialSheet steel, 1.25 mm, zinc passivated

Load rating120 N Static per unit

Supply schedule2 Chassis railsMounting material

How suppliedFlat-packed kit

TEL00157_E

MEC00029_E

NoteWhen choosing the chassis runner, please note the chassis depth d of thecabinet or enclosure

NoteWhen choosing the chassis runner, please note the chassis depth d of thecabinet or enclosure

Chassis RunnerScrew fittingW H D HU/U d L For cabinet type Order no. UP Price

600 365 311 miracel/smaract LAN 01.110.657.0 1 unit600 440 386 miracel/smaract 19” 01.110.726.0 1 unit800 565 511 miracel/smaract LAN 01.110.658.0 1 unit800 640 586 miracel/smaract 19” 01.110.727.0 1 unit900 665 611 miracel/smaract LAN 01.110.659.0 1 unit900 740 686 miracel/smaract 19” server 01.110.728.0 1 unit

500 460 428 doubleprorack 19” or door 01.110.791.0 1 unit600 435 386 doubleprorack LAN 01.110.726.0 1 unit600 485 453 doubleprorack 19” IP54 01.240.377.0 1 unit600 560 528 doubleprorack 19”or door 01.110.792.0 1 unit700 660 628 doubleprorack 19”or door 01.110.793.0 1 unit800 685 653 doubleprorack 19” IP54 01.240.379.0 1 unit

500 285 232 conact 05.010.346.9 1 unit600 285 332 conact 05.010.347.9 1 unit

- For installation in 19" cabinet and enclosure- For heavy installations

MaterialExtruded aluminium 2.0 mm

FinishPolished

Supply schedule1 Chassis runner

Load rating500 N Static per unit

TEM00066_E

MIR00220_E

TEM00069_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 273

Page 284: Shkaf Knurr Electronics e

by knürr

274

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

Chassis RunnerHook-inW H D HU/U d L For cabinet type Order no. UP Price

600 365 336 miracel LAN 01.131.223.7 1 unit800 565 536 miracel LAN 01.131.224.7 1 unit

- Quick and easy mounting- Only for installation in miracel cabinets

MaterialSheet steel, 2.0 mm

FinishZinc passivated, yellow chrome-plated

Load rating200 N Static per unit

Supply schedule1 Chassis runner

MIR00386_E

Chassis RunnerFor swing frameW H D HU/U d L Model Order no. UP Price

600/800 125 miracel 01.110.795.0 1 unit

- Mounting on the front-side vertical extrusion

MaterialExtruded aluminium, 2.0 mm

FinishPolished

Load rating200 N Static per unit

Supply schedule1 Chassis runner

TEM00068_E

NoteWhen choosing the chassis runner,note the chassis depth d of the cabinetor enclosure

NoteWhen choosing the chassis runner,note the chassis depth d of the cabinetor enclosure

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 274

Page 285: Shkaf Knurr Electronics e

by knürr

275

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size, mL(N) = Max. load rating/pair, A = Installation length, B = Extended lengthOrder no 1 = Installation position 1, Order no 2 = Installation position 2

NotePlease order assembly kit,order number 05.043.595.9

Ball Bearing Telescopic Slide, BP-400-LRPartial pull-outD d mL(N) A B C D E F G H I K For cabinet type Order no. 1 Order no. 2 UP Price600 365 500 330 220.5 328 279.4 152.4 101.6 63.5 111.1 miracel/smaract LAN 05.043.613.7 1 pair600 440 400 406 296.5 404 355.6 228.6 101.6 139.7 111.1 miracel/smaract 19” 05.043.616.7 1 pair800 565 410 533 407 531 482.6 241.3 101.6 139.7 127 111.1 miracel/smaract LAN 05.043.621.7 1 pair800 640 540 610 437.7 608 558.8 457.2 279.4 101.6 177.8 165.1 111.1 miracel/smaract 19” 05.043.624.7 1 pair900 665 500 660 488.5 658 609.6 508 304.8 101.6 203.2 190.5 111.1 miracel/smaract LAN 05.043.626.7 1 pair900 740 600 711 500 709 660.4 558.8 330.2 101.6 228.6 215.6 111.1 miracel/smaract 19” server 05.043.628.7 1 pair

500 460 400 406 296.5 404 355.6 228.6 101.6 139.7 111.1 doubleprorack 19” or door 05.043.616.7 1 pair600 435 460 356 245.5 354 304.8 177.8 101.6 88.9 111.1 doubleprorack LAN 05.043.614.7 1 pair600 485 400 406 296.5 404 355.6 228.6 101.6 139.7 111.1 doubleprorack IP54 05.043.616.7 1 pair600 560 440 508 381.5 505 457.2 228.6 101.6 127 114.3 111.1 doubleprorack 19” or door 05.043.620.7 1 pair700 660 540 610 437.7 608 558.8 457.2 279.4 101.6 177.8 165.1 111.1 doubleprorack 19” or door 05.043.624.7 1 pair800 635 600 559 386.8 557 508 406.4 254 101.6 152.4 139.7 111.1 doubleprorackLAN 05.043.622.7 1 pair800 685 540 610 437.7 608 558.8 457.2 279.4 101.6 177.8 165.1 111.1 doubleprorack IP54 05.043.624.7 1 pair

TEL00173_E

- 3/4 Pull-out, two-piece- Locking in pulled out position (friction lock)- Quick setup for removing and coupling the

chassis without tools

MaterialCold rolled steel

FinishSendzimir zinc passivated

Supply schedule1 Pair of telescopic slides

How suppliedFlat-packed kit

BP400AB_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 275

Page 286: Shkaf Knurr Electronics e

by knürr

276

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size, mL(N) = Max. load rating/pair, A = Installation length, B = Extended lengthOrder no 1 = Installation position 1, Order no 2 = Installation position 2

Stop Spring for Ball Bearing Telescopic SlidesW H D HU/U d L Model Order no. UP Price

interlocking 05.043.666.9 10 unitfriction lock 05.043.667.9 10 unit

- Quick and easy conversion from interlockingto friction lock or vice versa

- Conversion possible at any later stage

MaterialSpring steel

Supply scheduleSet of 10 units

Ball Bearing Telescopic Slide BF-480-FLRFull pull-outD d mL(N) A B C D E F G H I K For cabinet type Order no. 1 Order no. 2 UP Price600 365 455 356 381 354 323.9 311.2 298.5 200 0 miracel/smaract LAN 05.043.854.7 1 pair600 440 490 406 432.5 404 374.7 362 349.3 139.7 111.1 miracel/smaract 19” 05.043.856.7 1 pair800 565 510 559 584.5 557 527.1 514.4 501.7 415.9 263.5 292.1 111.1 miracel/smaract LAN 05.043.862.7 1 pair800 640 515 610 635.5 608 277.9 565.2 552.5 466.7 288.9 342.9 111.1 miracel/smaract 19” 05.043.864.7 1 pair900 665 520 660 686.5 658 628.7 616 603.3 517.5 314.3 393.7 111.1 miracel/smaract LAN 05.043.866.7 1 pair900 740 520 660 686.5 709 679.5 666.8 654.1 568.3 339.7 444.5 111.1 miracel/smaract 19” server 05.043.868.7 1 pair

500 460 490 406 432.5 404 374.7 362 349.3 139.7 111.1 doubleprorack 19” or door 05.043.856.7 1 pair600 435 455 356 381 354 323.9 311.2 298.5 200 0 doubleprorack LAN 05.043.854.7 1 pair600 485 490 406 432.5 404 374.7 362 349.3 139.7 111.1 doubleprorack IP54 05.043.856.7 1 pair600 560 510 508 530.5 506 476.3 463.6 450.9 365.1 238.1 241.3 111.1 doubleprorack 19” or door 05.043.860.7 1 pair700 660 515 610 635.5 608 277.9 565.2 552.5 466.7 288.9 342.9 111.1 doubleprorack 19” or door 05.043.864.7 1 pair800 635 510 559 584.5 557 527.1 514.4 501.7 415.9 263.5 292.1 111.1 doubleprorack LAN 05.043.862.7 1 pair800 685 515 610 635.5 608 277.9 565.2 552.5 466.7 288.9 342.9 111.1 doubleprorack IP 05.043.864.7 1 pair

BF480AB_E

ZUB80002_E

- Full extension, three-piece construction- Locking in pulled out position (interlocking)- Quick disconnect setup for removing and

coupling the chassis without tools

MaterialCold rolled steel

FinishSendzimir zinc passivated

Load rating400-530 N Static per runner pair depending on length

Supply schedule1 Pair of telescopic slides

How suppliedFlat-packed kit

NotePlease order assembly kit, order number 05.043.595.9

ZUB80003_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 276

Page 287: Shkaf Knurr Electronics e

by knürr

277

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

Mounting Kit for Ball Bearing RunnersW H D HU/U d L Model Order no. UP Price

05.043.595.9 1 unit

- For quick and easy mounting of telescopicrails BP-400-LR and BF-480-FLR

MaterialZincorium plate, 1.5 mm

Supply schedule4 Mounting bracketsMounting material

How suppliedFlat-packed kit

TEL00012_E

3 Point Hinged Cable RouterW H D HU/U d L Model Order no. UP Price

05.043.324.9 1 unit

- Ensures defined and kink-free routing ofheavy and rigid cable

- For quick and easy mounting behind the unit - Minimum space requirement behind the

pushed in unit, 38 mm- Mounting on the cabinet, the middle part of

the telescopic rail and the unit

FinishZinc passivated

Supply schedule1 Hinged cable router

TEL00162_E

Cable RollerW H D HU/U d L Model Order no. UP Price

05.043.327.9 1 unit

- For 19" cabinets and enclosures- Reduces cable strain on the unit - Makes cabling tidy- Prevents cables from sagging

MaterialSheet steel, 1.5 mm

Supply schedule1 Cable roller

TEL00034_E

19" Cable Routing PanelW H D HU/U d L Model Order no. UP Price19” 44.5 1 01.117.020.1 1 unit19” 88.1 2 01.117.022.1 1 unit

- For routing cables in the internal cabinetspace

- With edge protector

MaterialSheet steel, 1.5 mm

FinishPowder-coated, RAL 7035 light-grey

Supply schedule1 19" Cable routing panel

CUD00021_E

CUD00023_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 277

Page 288: Shkaf Knurr Electronics e

by knürr

278

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

19" Fibre Optic Cable Routing Panel2 HU/UW H D HU/U d L Model Order no. UP Price19” 88.1 2 01.117.019.1 1 unit

- For safe cable routing of fibre optic cables

MaterialSheet steel, 1.5 mm

FinishPowder-coated, RAL 7035 light-grey

Supply schedule1 19" Cable routing panel

LIG00070_E

LIG00024_E

19" Cable Routing Panel1 HU/UW H D HU/U d L Model Order no. UP Price19” 44.5 1 type 1 01.117.044.1 1 unit19” 44.5 1 type 2 01.117.144.1 1 unit

- For safe and orderly routing of fibre opticand copper cables

Material / FinishFront panel, sheet steel, 1.5 mm,powder-coated, RAL 7035 light-grey

DimensionsCable routers:Type 1: 55 x 22 mm, plasticType 2: 95 x 32 mm, steel

Supply schedule1 19" Front panel5 Cable routersMEC00110_E

Cable Clamping Bracket / Earthing BarW H D HU/U d L Model Order no. UP Price

01.117.035.7 1 unit

CUD00025_E

CUD00024_E

- For 19" cable routing panel- For cable strain relief and plug connections

with cable ties

MaterialSheet steel, 1.5 mm

FinishZinc passivated, Zn 10c white

Supply schedule1 Earthing barMounting material

Cable ClipsW H D HU/U d L Model Order no. UP Price

05.041.066.7 100 unit

- Conductive surface for good earth connection

Supply schedule100 Cable clips

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 278

Page 289: Shkaf Knurr Electronics e

by knürr

279

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

C-Shaped RunnerW H D HU/U d L Model Order no. UP Price

600 position 1 miracel 01.130.858.9 1 unit800 position 1 miracel 01.130.860.9 1 unit600 position 2 miracel 01.130.859.9 1 unit800 position 2 miracel 01.130.861.9 1 unit900 position 2 miracel 01.130.854.9 1 unit600-900 position 3 miracel/smaract/doubleprorack 01.110.719.9 1 unit600 position 4 miracel/smaract/doubleprorack 01.113.790.9 1 unit800 position 4 miracel/smaract/doubleprorack 01.113.791.9 1 unit400-600 rear panel conact 05.010.340.9 1 unit

- For cable clamping with hoop clips or cableclamping strip. Mounting is space-savingbetween the extrusions of the basic rack

MaterialSheet steel, zinc passivated

Supply schedule1 RunnerMounting material for cabinets with T-slotextrusions

U-ClampW H D HU/U d L Model Order no. UP Price

8-12 mm 01.110.711.9 1 unit12-16 mm 01.110.712.9 1 unit16-22 mm 01.110.713.9 1 unit22-28 mm 01.110.714.9 1 unit34-40 mm 01.113.176.9 1 unit40-46 mm 01.113.127.9 1 unit

- For strain relief and individual cable and linerouting

- Clamping range 8-46 mm

Supply schedule1 U-Clamp1 Clamping saddle

ELM00086_E

MEC00114_E

MEC00096_E

MEC00097_E

Cable Clamping StripW H D HU/U d L Model Order no. UP Price

01.130.869.9 10 units

- For clipping on the C-shaped runner

MaterialPolyamid, black

Supply schedule1 Set of 10 cable clamping strips

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 279

Page 290: Shkaf Knurr Electronics e

by knürr

280

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

ELM00049_E

ELM00050_E

Cable TieW H D HU/U d L Model Order no. UP Price

01.240.548.9 20 units

- For tidy cable routing- For fixing cable harnesses and lines with

large cross section- Quick and easy mounting- For clipping into T-slots at any position - With detachable catch

MaterialPolyamid, black

Supply schedule20 Units

Cable HookW H D HU/U d L Model Order no. UP Price

01.117.034.3 1 set

- For 19" distribution panel- For orderly cable routing with jumpering- Open version, no tedious cable looping

FinishPowder-coated, RAL 7032 textured

MaterialSheet steel, 3.0 mm

Supply schedule2 Cable hooksMounting material

CUD00027_E

CUD00029_E

Swing Frame Cable ClampW H D HU/U d L Model Order no. UP Price

01.113.203.1 1 set

- Highly recommended for use with a swingframe

- For cable strain relief- For load reduction on plug connections - Prevents damaging of cable braided

shielding

Supply schedule2 Mounting brackets1 C-Shaped runnerMounting material

MIR00086_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 280

Page 291: Shkaf Knurr Electronics e

by knürr

281

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

Cable Routing HookW H D HU/U d L Model Order no. UP Price

01.113.153.9 1 unit

- For tidy cable routing- Open version, no tedios cable looping- Cross section for cable routing, variable with

removable routing spacers- Expandable by adding additional cable

routing hooks- Mounting optional length-ways or across the

width

ColourBlack RAL 9001

Supply schedule1 Cable routing hookMounting material

Cable Routing RingW H D HU/U d L Model Order no. UP Price

01.312.207.9 5 units

- For orderly cable routing - Open version, no tedious cable looping- Mounting on the T-slots of the vertical

extrusions- Installation position selectable

Supply schedule5 Cable routing ringsMounting material

Cable Routing SetW H D HU/U d L Model Order no. UP Price

01.117.528.9 10 units

- For orderly cable routing - Dimensions:

external 61 mm x 42.5 mminternal 52 mm x 23 mm

Supply schedule10 Cable routers

ELM00024_E

ELM00025_E

MEC00112_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 281

Page 292: Shkaf Knurr Electronics e

by knürr

282

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

Fibre Optic Cable RouterW H D HU/U d L Model Order no. UP Price

01.117.099.1 1 pair

LIG00068_E

LIG00021_E

MIR00184_E

- For safe and orderly cable routing of fibreoptic cables

- With step-index extrusion for implementingstrain relief of fibre optic cables

- Mounting on the external side T-slot of the19” extrusion

MaterialPA UL 94 VO

Supply schedule1 Pair of fibre optic cable routersMounting material

Assembly CrossbarW H D HU/U d L Model Order no. UP Price

800 chassis depth d = 565 mm 01.113.748.1 unit

- For cable routing with cable binders- Universal mounting option for installation

accessories like cable ducts, socket strips,telecommunications installation units,mounting panels etc.

- For side installation

Supply schedule1 Assembly crossbar

MIR00089_E

MIR00164_E

MIR00090_E

Multifunctional StrutW H D HU/U d Model For cabinet type Order no. UP Price

600 type A position 1 miracel 01.130.775.0 1 unit800 type A position 1 miracel 01.130.776.0 1 unit900 type A position 1 miracel 01.130.777.0 1 unit

600 type A position 2 miracel 01.130.783.0 1 unit800 type A position 2 miracel 01.130.785.0 1 unit600–800 type A position 3 miracel/smaract/doubleprorack 01.130.787.0 1 unit

600 type A position 4 miracel/smaract LAN 01.130.778.0 1 unit800 type A position 4 miracel/smaract LAN 01.130.779.0 1 unit600 type A position 4 miracel/smaract 19” 01.130.780.0 1 unit800 type A position 4 miracel/smaract 19” 01.130.781.0 1 unit

600 type B position 1 miracel 01.131.291.0 1 unit800 type B position 1 miracel 01.131.292.0 1 unit

600 type B position 2 miracel 01.131.299.0 1 unit800 type B position 2 miracel 01.131.301.0 1 unit600/800 type B position 3 miracel/smaract/doubleprorack 01.131.303.0 1 unit

600 type B position 4 miracel/smaract LAN 01.131.294.0 1 unit800 type B position 4 miracel/smaract LAN 01.131.295.0 1 unit

- For guiding cables with cable binders andfor universal mounting

- Holes for mounting caged nuts- Distance between two multifunctional struts

can be varied using the T-slot - Installation on the basic rack extrusions or

on the 19” extrusions, across and on theside

- Type A - for universal application- Type B - specifically for mounting with cable

binders, no threading required

MaterialSheet steel, 1.5 mm

FinishType A electrolytic zinc passivatedType B zinc passivated

Installation positions1 on the basic rack in the depth2 on the basic rack on the width3 on the 19"extrusions on the width4 on the 19” extrusions in the depth

Supply schedule1 Multifunctional member

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 282

Page 293: Shkaf Knurr Electronics e

by knürr

283

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

Jumpering Bracket, SquareW H D HU/U d L Model Order no. UP Price

86 x 86 01.113.744.7 1 unit

- For orderly cable routing- Open version, no tedious cable looping- Mounting on the external side T-slot of the

19" extrusion- Installation position freely-selectable- From cabinet width 800 mm

FinishZinc passivated, Zn 10c white

Supply schedule1 Jumpering bracket, square

MIR00183_E

ELM00006_E

Jumpering Bracket, RectangularW H D HU/U d L For cabinet type: model Order no. UP Priceab 800 miracel type 1: 38 x 288 01.113.749.7 1 unitab 700 miracel type 2: 24 x 288 01.117.179.7 1 unit600 smaract type 2: 24 x 288 01.117.179.7 1 unit

doubleprorack type 3: 40 x 65 01.240.551.7 1 unit

- For orderly cable routing- Open version, no tedious cable looping- Mounting on the external side T-slot of the

19" extrusion- Installation position freely-selectable

FinishZinc passivated, Zn 10c white

Supply schedule1 Jumpering bracket, rectangular

Cable DuctW H D HU/U d L Model Order no. UP Price

2000 01.117.098.3 1 unit

- Ideal for tidy and hidden cable routing ofjumpering cables

MaterialHard PVC

FinishStone-grey RAL 7030

Supply schedule1 Cable duct with coverMounting material

Jumper TiebarW H D HU/U d L Model Order no. UP Price

01.117.033.7 2 units

- Ideal for vertical cable routing and strainrelief

- Open version, no tedious cable looping- Mounting on the external side T-slot of the

19" extrusion- Installation position freely-selectable- From cabinet width 600 mm

FinishZinc passivated, Zn 10c white

Supply schedule2 Jumper tiebars

ELM00004_E

ELM00028_E

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 283

Page 294: Shkaf Knurr Electronics e

by knürr

284

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

Mounting Set, T-Slot M5 For miracel / smaractW H D HU/U d L Model Order no. UP Price

05.041.311.9 1 set

MIR00119_E

- For mounting front panels, chassis runnersand other installations

Supply schedule100 Enlarged spring nuts M5 for T-slot M6100 Phillips head screws M5 x 12100 Rosettes20 Socket head screws20 Caged nuts M 5

Mounting Set Mounting Holes M5 For miracel / smaractW H D HU/U d L Model Order no. UP Price

05.041.312.9 1 set

MIR00122_E

- For mounting front panels, chassis runnersand other installations

Supply schedule200 Caged nuts M5100 Phillips head screws M5 x 16100 Rosettes20 Enlarged spring nuts M5

for T-slot M620 Socket head screws M5 x 8

Mounting Set, T-Slot M5 For doubleprorackW H D HU/U d L Model Order no. UP Price

05.041.292.9 1 set

- For mounting front panels, chassis runnersand other installations

Supply schedule200 Spring nuts M 5100 Phillips head screws M5 x 12100 Rosettes100 Socket head screws M5 x 10

Mounting Set Mounting Holes M5 For doubleprorackW H D HU/U d L Model Order no. UP Price

05.041.291.9 1 set

- For mounting front panels, chassis runnersand other installations

Supply schedule200 Caged nuts M5100 Phillips head screws M5 x 16100 Rosettes

80 Spring nuts M5 80 Scoket head screws M5 x 10

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 284

Page 295: Shkaf Knurr Electronics e

by knürr

285

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

MIR00122_E

Mounting Set Mounting Holes M5 for conactW H D HU/U d L Model Order no. UP Price

05.010.331.9 1 set

- For mounting front panels, chassis runnersand other installations

Supply schedule50 Cage nuts M 550 Phillips head screws M5 x 1650 Rosettes25 Serrated (tooth) locking nuts

Cage Nut M5W H D HU/U d L Model Order no. UP Price

for material strength 1.5 mm 05.041.513.7 1 setfor material strength 2.5 mm 05.041.518.7 1 set

- For clipping into extrusions with mountingholes

MaterialSteel, zinc passivated and yellow chrome-plated

Supply schedule1 Set of 50 units

Mounting Tool for Cage NutW H D HU/U d L Model Order no. UP Price

01.130.985.9 1 unit

MIR00114_E

- For making it easier to clip in the cage nuton the extrusions

MaterialSpring steel

Supply schedule1 Mounting tool

Sliding NutW H D HU/U d L Model Order no. UP Price

standard, M 2.5 05.041.520.7 1 setstandard, M 3 05.041.521.7 1 setstandard, M 4 05.041.522.7 1 setflat, M 3 05.041.526.7 1 set

MEC00070_E

- For inserting in the extrusions

MaterialZinc passivated steel

How supplied1 Set of 50 units

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 285

Page 296: Shkaf Knurr Electronics e

by knürr

286

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

Oval Head ScrewWith phillips head W H D HU/U d L Model Order no. UP Price

5 M 2.5 without washer 05.041.600.8 1 set8 M 2.5 without washer 05.041.602.8 1 set6 M 3 without washer 05.041.604.8 1 set6 M 4 without washer 05.041.606.8 1 set8 M 4 without washer 05.041.607.8 1 set8 M 5 without washer 05.041.611.8 1 set12 M 4 without washer 05.041.609.8 1 set

12 M 5 with washer 05.041.613.8 1 set16 M 5 with washer 05.041.614.8 1 set16 M 6 with washer 05.041.616.8 1 set

MEC00014_E

- IEC DIN EN ISO 7045

Supply schedule1 Set of 50 units

Oval Head ScrewWith phillips head and rosetteW H D HU/U d L Model Order no. UP Price

12 M 5 05.041.203.9 1 set16 M 5 05.041.290.9 1 set

MIR00116_E

- IEC DIN EN ISO 7047

Supply schedule1 Set of 50 units

Spring NutM5W H D HU/U d L Thread Order no. UP Price

miracel/smaract M5 01.350.431.9 1 setdoubleprorack M5 05.041.503.9 1 set

MEC00060_E

- For clipping into the T-slot at any position

MaterialSteel, St 1203Spring band, Nirosta 4310

Supply schedule1 Set of 50 units

Socket Head ScrewsWith hexagonW H D HU/U d L Model Order no. UP Price

6 M 5 05.041.573.8 1 set8 M 5 05.041.574.8 1 set8 M 5 micro encapsulated 05.041.575.9 1 set

MEC00013_E - IEC ISO 4762 (modified)

Supply schedule1 Set of 50 units

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 286

Page 297: Shkaf Knurr Electronics e

by knürr

287

SYSTEM ACCESSORIES

Dimensions in mm: W = Width, H = Height, D = Depth, h = Max. inst. height, d = Useful depth / chassis depthHU/U = Standard height unit (Unit), UP = Unit of packaging, kg = Weight, CW = Clear widthL = Length, W x L = Overall size

Socket Head ScrewsWith hexagonW H D HU/U d L Model Order no. UP Price

10 M 5 05.041.598.8 1 set

- DIN 6912

Supply schedule1 Set of 50 units

Hexagon Head Screw With contact washer M 4 x 12W H D HU/U d L Model Order no. UP Price

05.041.577.8 1 set

- IEC DIN EN 24017- For mounting cross extrusions in 19"

modular chassis’

Supply schedule1 Set of 50 units

Countersunk Screw With phillips headW H D HU/U d L Model Order no. UP Price

6 M3 05.041.581.8 1 set10 M3 05.041.583.8 1 set10 M4 05.041.585.8 1 set8 M5 05.041.589.8 1 set10 M5 05.041.590.8 1 set12 M5 05.041.591.8 1 set

- IEC DIN EN ISO 7046

Supply schedule1 Set of 50 units

MEC00013_E

MEC00017_E

Countersunk Screw With phillips head and tensiloc nutW H D HU/U d L Model Order no. UP Price

12 M5 05.041.593.8 1 set

- IEC DIN EN ISO 7046

Supply schedule1 Set of 50 units

MEC00017_E

Tensiloc NutW H D HU/U d L Model Order no. UP Price

M 5 05.041.533.8 1 set

MaterialNickel-plated steel

Supply schedule1 Set of 50 units

226-288_eng_final.qxd 07.08.2002 16:02 Uhr Seite 287

Page 298: Shkaf Knurr Electronics e

by knürr

288

INDEX

1 U keyboard drawer 22000015” TFT Display 22000019” Adapter, outdoor wall cases 883319” Chassis 8888,, 889919” Extrusions, miracel 227719” Extrusions, conact 663319” Extrusions, doubleprorack 556619” Extrusions, smaract 444419” keyboard 119988,, 119999

Accessories, electrical 226600Accessories, mechanical 226611Add on cabinet, tecoras outdoor 6699Add on enclosure, tecoras outdoor 6699Air-Inhibiting Plate 112211ASP rack, miracel 1122ATX 116622

Backplane 114477,, 114499,, 115511,, 115533,, 115544Base plate, miracel 2244Basic cabinet, tecoras outdoor 6688Basic frame, miracel 88//1144Basic rack, miracel 88//1144Battery base, tecoras 7799,, 8833Battery modules 117766,, 117799,, 118800,, 118833,, 118844Baying kit, miracel 3300Bench Chassis Enclosure 9988Bench Enclosure 111111Blank panel, 19” 226633Blanking Cover 116655BN 411002, Primus 112255Bottom panel, miracel 2244Brush strip, miracel plinth 2244Brush strip, miracel top 2266Bus Systems 114455

Cabinet Monitoring 119911Cable band clip 228800Cable bracket 228800Cable carrier 227777Cable clamp bracket, 19” 227788Cable clamp strip 227799Cable clamp, swing frame 228800Cable duct 228833Cable entry panel, 19” 227777Cable entry panel, closed 7777Cable entry trough with filter 7777Cable entry trough 7777Cable guide panel, 19” 227788Cable guide 228811Cable guide, fibre optics 228822Cable jumper 228811Cable junction box 226600Cable roller 227777Cable tie bar 228822Cable tray, miracel W700 1122Cardcage, 9911,, 112233Card Frame 9911,, 9977,, 111111,, 112233Card Holder 116644Cassettes 114422Castor, doubleprorack 5555Castor, smaract 4455CDROM Server 116699Chasseleon 9977,, 116622Chassis Rails 110055Chassis runner 227733,, 227744Chassis tray, 19” 227722Classic PDU 220033,, 221144,, 222244,, 222299Climate 224411Coding 113300,, 114466Cooling systems 224499Colocation rack, miracel 1133Combi - PDU 221111,, 222211Compact keyboard 119988,, 119999Compact lamp 226600CompactPCI 111122,, 111188,, 114466,, 114499,, 115588CompactPCI Backplane 114499CompactPCI System Chassis 114477Compact PDU 220044,, 221144,, 222288,, 223300Conact with glass door 6622Conact 5599Connection board, miracel 3311Connection panel, cabel entry, miracel 3311Connection panel, cable entry,

doubleprorack 5533Connector kit, miracel 3300Console switch 118855Cooling unit, 19” 224499Cooling unit, top-mounting 225511Cooling unit, wall-mounting 225500Cover extrusion, for rack suites, miracel 3300Cover, miracel top 2255Covers, conact 6644

Covers, smaract 4444C-shaped runner 227799CS 2007 8877Cylinder lock, miracel 2211

Dart Fan unit, 19” 224422Dart fan unit, 19”, not regulated 224433Dart fan unit, 19”, speed-controlled 224444DC backup systems, Tecoras 223333DDC, tecoras outdoor 7700Depth strut 7799Desktop enclosure, Micado 111111Disk Drive Chassis 114411Display 220000Distribution Box 223399--224400Distribution rack, miracel 88Distributor rack, miracel 88Di-strip 220011Door contact switch 226611Doors, conact 6633Doors, doubleprorack 5522Doors, miracel 2200Doorstop, miracel 2211Double door cabinet, tecoras outdoor 7700Doubleprorack with glass door 5511Doubleprorack without door 5500Doubleprorack 4477Drawer, 19” 226688,, 226699DWC, tecoras outdoor 6688,, 6699

Earth sets, miracel 3311Earthing bar 226611Earthing bar, doubleprorack 5577Earthing Set 112211Earthing set, conact 6644Earthing set, doubleprorack 5566,, 5577Economy Modular Chassis, Eurocard 9944EMC components, miracel 1166EMC Kit, Micado 112222,, 113311EMC rack, miracel 1155//1177EMC small rack, smaract 4433Emshield 116622Enclosure Monitoring 119911Equipotential bonding bar 226611ESD Springs 112299ETS rack 23” 3377ETS rack H1800, welded 3366ETS rack H2200, welded 3355ETS rack, earthquake-proof 3366ETS rack, flat pack 3355Eurocard 9911Euro Socket system 222266Eyebolt set, doubleprorack 5577

Fan unit, 19”, tangential fan 224466Fan unit, dart 224422Fan unit, doubleprorack 5533Fan unit, miracel EMC 1166Fan unit, smaract 4455Fan, top-mounting 224466,, 224477Filter fan 224488Filter Mat, Micado 112211Filter mat, miracel plinth 2244Filter unit, 19” 224455Floormounting, miracel 2299Front door, closed, ETS 3355Front door, perforated, ETS 3355Front Panel 110044,, 113322,, 113366,, 113388Front panel, 19” 226622Front panel, 19”, hinged 226633Front panel, 19”, ventilation 226633,, 226644Front trim, pivoted, miracel 2266

Glass door, miracel 2200Grounding sets, miracel 3311GST18 Plug System for PDUs 221122,, 222222Guide Rails 110066,, 112299,, 114433

Handles 114400Heat Exchanger Cabinet, tecoras outdoor 7711Heat exchanger, 19” 225522,, 225533Heat exchanger, wall-mounting 225544Heater 225555Heating systems 225522Heavy Duty Chassis, CS 2007 8888Heavy-duty shelf, fixed 226677Heavy-duty shelf, full extension 226677HEC, tecoras outdoor 7711,, 7766,, 8822 Hot Swap 114400,, 114466,, 114499Hot swap batteries 117755,, 117799,, 118822Hygrostat 225577

IEC320 222266IEEE 1101.10/11 111122,, 111188,, 112244,, 114466,, 115500Indoorrack, miracel 55Installation extrusions,

19”/Metric miracel 2277Insulating Strip 110099,, 112288Interlock Spring 110066I/O Shield 116644IPC 116611IP 54 small rack, smaract 4433IP 54, connection panel, cable entry,

doubleprorack 5555IP 54, connection panel, doubleprorack 5544IP 54, doubleprorack 5500IP 54, fan unit, doubleprorack 5544IP 54, rear panel, doubleprorack 5544IP 55 rack, miracel 1155ISP partition panel, miracel 1133ISP rack connector 1133ISP rack, miracel 1133

Jumpering bracket 228833

Keyboard drawer 1U, 19” 227700,, 227711Keyboard 119988,, 119999Keyboard/Video/Mouse switch 119911KVM switch 118855

Lab rack 88Label Strips 112288Lamp 226600Line Interactive 117733Lock cylinders, miracel 2211

Master Slave - PDU 221100,, 222200Micado 111111Microswitch 114400Miracel 55Mobile plinth, miracel 2233Modular Chassis 9922,, 112244Monitoring Module 115555Monitoring, Rack Monitoring 119911Monting kit, floormounting miracel 2299Mounting extrusions, 19”/Metric miracel 2277Mounting hardware 228844--228877Mounting kit, screws, sidepanels miracel 2299Mounting kits, 19” extrusions miracel 2288Mounting panel, tecoras 7788Mounting set, conact 6622Multifunction member, Miracel 228822

Network equipment rack 88Networkrack, miracel 55NF F 60-002 112255NG 800 1111NO 19 88Non-interaction time 117766,, 117799,, 118800,, 118833,, 118844NS 19.6 88NS 19.8 D 1100NS 19.8 99NS 25 1100

Online 117733,, 117744Open Frame, power supply 115599

PDU French layout 221144PDU Swiss layout 222244PDU UK layout 222288PDU US layout 222299PDU 220011Plinth trim, ETS 3355Plinth, fibre-glass, tecoras SC 7788Plinth, metal, tecoras SC 7777Plinth, miracel 2233Plinths, doubleprorack 5555Power Cleaner – PDU 220077,, 221177Power distribution unit 220011Power Pack 115588Power Supply Unit,

Maxi DC UPS 750W–3750W 223366--223377Power Supply Unit,

Midi DC UPS 200W–1000W 223366--223399Power Supply Unit,

Mini DC UPS 25W 223399Primus 112233Protector Emergency Off – PDU 220066,, 221166Protector Emergency Stop

FI / LS PDU 220077,, 221177Protector FI – PDU 220055,, 221155Protector FI / LS – PDU 220066,, 221166,, 222255Protector LS – PDU 220055,, 221155Pulsar Evolution 117733,, 117755Pulsar Extreme C 117733,, 117777Pulsar Extreme 117744,, 118811

Rack connector, ISP miracel 1133Rack connector, miracel 3300Rack Monitoring System 119911racks, miracel 55RAID 116677Rear door, smaract 4455Rear panel, doubleprorack 5522Rear panel, ETS 3355Rearpanel, miracel 2222Recessed Card Space 115522Rectifier system,

Maxi DC UPS 750W–3750W 223366--223377Rectifier system,

Midi DC UPS 200W-1000W 223366--223399Rectifier system, Mini DC UPS 25W 223399RMS 119911Roof, closed, ETS 3355

Safety Basic – PDU 220088,, 221188,, 222299Safety Standard – PDU 220099,, 221199,, 222255SC Fan, tecoras outdoor 7755SC HEC 7766SC, tecoras outdoor 7733 ffffScrew Driver, TX 8 113355Serimat 223311,, 223322Server 116688,, 116699Server extrusions, 19” miracel 2288Serverrack, miracel 1111Sheet door, miracel 2200Shelf, fixed 226655Shelf, full extension 226666Shelf, heavy duty 226677Shelf, partial extension 226666Sidepanel, miracel 2222Slot Cover 116644Small rack, doubleprorack 4477Small rack, smaract 3399Smaract with glass door 4422Smaract with perforated door 4422Smaract without door 4422Smaract 3399Socket strips 220011Steel door, miracel 2200Street Cabinet, tecoras outdoor 7733 ffffSurge Protector PDU 223300Swingframe rack, miracel 1100Swingframe, miracel 2288Switch, KVM 118855System master switch field 223399––224400System Monitoring 119911

Tapped Strip 110099,, 112288Technical data, miracel 66Technical details, DC Backup Systems 223344Tecoras DC backup systems 223333Tecoras indoor EMC rack 1177Telescopic Rails, chasseleon 9922,, 110055Telescopic slides, full extension 227766Telescopic slides, partial extension 227755Temperature modul 225566Terminal box 226600TFT 119977,, 220000Thermostat 225577Topcover, miracel 2255Torx screw M4 113355Touchpad 119988Trim extrusion, miracel 3311

U-clamp 227799Universal cable entry brushes 7777Universal cable entry EMC 7777Universal cable entry foam 7777UPS, Uninterruptible power supply 117711

Ventilation systems 224422Vertical extrusions, 19”/Metric, tecoras 7799Vertical extrusions, miracel 2277VME-64 111122,, 111188,, 114466,, 115500,, 115533VME64x Backplane 115533VME64x System Chassis 115500VME Backplane 115544VME System Chassis 115511,, 115555

Wall Case HEC, tecoras outdoor 8822Wall Case, tecoras outdoor 8822 ffff..Wall Mounting, tecoras outdoor 8833Wall-mounting rack, conact 5599WC HEC, tecoras outdoor 8833WC, tecoras outdoor 8822 ffff..

Z-Rails 9944,, 110088

M

I R

S

T

U

V

W

Z

1

A

B

C

D

E

F

G

H

N

O

P

J

K

L

226-288_eng_final.qxd 07.08.2002 15:16 Uhr Seite 288

Page 299: Shkaf Knurr Electronics e

Dokument 2 20.09.2002 11:31 Uhr Seite 1

Page 300: Shkaf Knurr Electronics e

09.9

97.4

67.9

• 6

' GG

• 0

7/02

• ©

200

2 •

Gra

phik

, Red

aktio

n: U

lric

h H

uber

Erro

rs a

nd o

mm

issi

ons

exce

pted

. Pri

ces

and

spez

ifica

tions

sub

ject

to c

hang

e.

Knürr AGHead Office

Mariakirchener Straße 3894424 Arnstorf • GermanyTel. +49 (0) 87 23 / 27 - 0Fax +49 (0) 87 23 / 27 - 154www.knuerr.com

by knürrE N V I R O N M E N T S F O R E L E C T R O N I C S

Sales Office HamburgHalstenbeker Weg 96a25462 RellingenTel. +49 (0) 41 01 - 40 01-0Fax +49 (0) 41 01 - 40 01-99

Sales Office CologneEmil-Hoffmann-Straße 1 A50996 Köln (Rodenkirchen)Tel. +49 (0) 22 36 - 89 00 - 0Fax +49 (0) 22 36 - 89 00 - 99

Sales Office LeipzigStöhrerstraße 1704347 LeipzigTel. +49 (0) 3 41 - 24 51 5-0Fax +49 (0) 3 41 - 24 51 5-99

Sales Office MunichSchatzbogen 2981829 MünchenTel. +49 (0) 89 - 4 20 04-200Fax +49 (0) 89 - 4 20 04-199

Sales Office StuttgartSteinbeisstraße 471229 LeonbergTel. +49 (0) 71 52 - 93 67-0Fax +49 (0) 71 52 - 93 67-99

Wo r l d - w i d e ... and close to the customer

Germany

Hong KongTELEROUTE Communications LimitedUnit B, 5/F, Gee Hing Chang IndustrialBuilding,16 Cheung Yue Street, Cheung Sha WanKowloon Hong KongTel. +852 ( ) 28 51 22 11Fax +852 ( ) 28 51 20 60

Knürr Ltda.Rua Antônio Galvão Pacheco, 18518550-000 - Boituva - Sao PauloTel. +55 (0) 15 - 2 63-24 44Fax +55 (0) 15 - 2 63-10 [email protected]

South-KoreaMULTITEK# 505 Jeil Industrial Building323-1 Dang Jung Dong, Kun Po CityKyung Ki Do # 435-030Tel. +82 (0) 3434 - 57 08 16Fax +82 (0) 3434 - 58 08 [email protected]

AustraliaRicon Pty LtdUnit 1, 32 Lilian Fowler PlaceMarrickville NSW 2204Tel. +61 (0) 2 95 19 - 48 77Fax +61 (0) 2 95 19 - 46 [email protected]

AustriaGrothusen Ges.m.b.H.Albert-Schweitzer-Gasse 51140 WienTel. +43 (0) 1 - 9 70 22 -0Fax +43 (0) 1 - 9 70 22 [email protected]

Czech RepublicAutoCont Control Systems spol. s r.o.Nemocnicni 1270200 Ostrava 2Tel. +420 (0) 69 - 6 15 23 92Fax +420 (0) 69 - 6 15 21 [email protected]

Brazil

DenmarkSkaarup Imcase A/SVasekaer 6-82730 HerlevTel. +45 ( ) 44 85 04 85Fax +45 ( ) 44 94 99 [email protected]

FinlandPerel OyTorpankatu 2805801 HyvinkääTel. +358 (0) 19 - 8711 1Fax +358 (0) 19 - 8711 [email protected]

FranceKnürr s.a.r.l.ZAC Les Petits Carreaux4, Avenue des Violettes94384 Bonneuil-sur-MarneTel. +33 (0) 1 43 77 85 85Fax +33 (0) 1 43 39 02 [email protected]

HungaryKontaset Kft.Helsinki ut. 531201 Budapest XX.Tel. +36 (0) 1 4 21- 30 08Fax +36 (0) 1 4 21- 30 [email protected]

IndiaKirloskar Electrodyne Ltd.117, S BlockM.I.D.C. BhosariPune 411026Tel. +91 (0) 20 - 7 12 01 21 Fax +91 (0) 20 - 7 12 03 [email protected]

IsraelAlexander Schneider Ltd.54 Hazoran St.Netanya 42504Tel. +972 (0) 9 - 892 44 44Fax +972 (0) 9 - 892 44 [email protected]

JapanCEC, Chuo Electronics Co., Ltd.Daiichi Seimei bldg., 7 Fl.3-20-6, Myojin-choHachioji-shi, 192 Tokyo Tel. +81 (0) 4 26 - 56 - 58 11Fax +81 (0) 4 26 - 56 - 58 [email protected]

NetherlandsKnürr BVPaardeweide 84824 EH BredaTel. +31 (0) 76 - 54 22 92 2Fax +31 (0) 76 - 54 21 01 [email protected]

PortugalSociedade Zickermann S.A.Rossio, 3, Apartado 21151103 Lisboa CodexTel. +351 (21) 3 22 41 63Fax +351 (21) 3 22 41 [email protected]

PolandPIOMARUl. Swiderska 3503-128 WarszawaTel. +48 (22) 6 76 94 62Fax +48 (22) 6 76 98 [email protected]

SingaporeKnuerr-Spectra (S.E.A.) Pte Ltd.No. 1, Lok Yang WayUnit # 01 - 19 CSingapore 628623Tel. +65 ( ) 67 73 - 1583Fax +65 ( ) 67 73 - [email protected]

SpainS.I.G., S.A.Suecia, 8 Polig. Ind. Jumapi28812 Alcalá de Henares (Madrid)Tel. +34 (91) 8 89 89 61Fax +34 (91) 8 89 84 [email protected]

SwedenKnürr ASDjupdalsvägen 2719251 SollentunaTel. +46 (0) 8 - 59 47 07 50Fax +46 (0) 8 - 59 47 07 [email protected]

SwitzerlandKnürr AGBruggacherstraße 168117 FällandenTel. +41 (0) 1 8 06 54 54Fax +41 (0) 1 8 06 54 [email protected]

United KingdomKnürr (UK) Ltd.Burrel RoadSt. Ives, Cambs. PE17 4LETel. +44 (0) 1480 49 61 25Fax +44 (0) 1480 49 63 [email protected]

USAKnürr Inc.1890 North Voyager AvenueSimi Valley, CA 93063Tel. +1 (805) 5 26 - 77 33Fax +1 (805) 5 84 - 83 [email protected]

NorwayKnürr NorgeExclusive Dealer ASIndustriveien 252020 Skedsmokorset Tel. +47 ( ) 64 83 84 40Fax +47 ( ) 64 83 84 [email protected]

MaltaBaron Networks LtdBaron HouseSt. Anthony StreetMosta MST 08Tel. +356 ( ) 418255Fax +356 ( ) [email protected]

GreeceBEST A.E.3rd km Symmachikis odou Oraiokastrou570 13 PalaiokastroThessalonikiTel. +30 (0) 310 -69 11 90Fax +30 (0) 310 -69 11 [email protected]

RussiaUNI Corporation13, 2nd Zvenigorodskaya str.Moscow, 123022Tel. +7 (095) - 956-64-44Fax +7 (095) - [email protected]

EgyptUniversal Advanced Systems31 Manshiet El Bakry st., HeliopolisP.O. Box 5267 Heliopolis-WestCairo 11771Tel. +20 (0) 2 455 - 6744Fax +20 (0) 2 256 - [email protected]

ItalyForind AvioElettronica SpAVia Copernico, 620060 Cassina de'PecchiTel. +390 (0) 2 95 34 30 80Fax +390 (0) 2 95 34 31 [email protected]

SlovakiaAutoCont a.S.Schneidra- Trnavského 684101 BratislavaTel. +421 (0) 7 - 64 28 78 81Fax +421 (0) 7 - 64 28 78 [email protected]

TaiwanTaiwan Yukosa Co.Ltd.7F, #38, Ssu-Yuan Rd.,Hsin-Chuang City, Taipei CountyTel. +886 (0) 2 - 22 76 - 10 19Fax +886 (0) 2 - 22 79 - 88 [email protected]

ChinaTelesun Electronics Engineering TechniqueNo.A8 Langqiuyuan, TayuanxiaoquHaidian District100083 BeijingTel. +86 (0) 10 62 38 58 28Fax +86 (0) 10 62 38 58 [email protected]

BelgiumKnürr BVPaardeweide 84824 EH BredaTel. +32 (0) 3 - 4 5077 77Fax +31 (0) 76 - 5 42 10 [email protected]

LBW-Elektronik ABBox 4044, Alvägen 217504 JärfällaTel. +46 (0) 8 58 41 08 80Fax +46 (0) 8 58 02 67 [email protected]

UnitedArab Emirates

Dafnia Electronics L.L.C.P.O. Box 32 788DubaiTel. +971 (0) 4 - 335 29 95Fax +971 (0) 4 - 334 99 [email protected]

Sweden

SwedenBEJOKEN ABTravbanegatan 221377 MalmöTel. +46 (0) 40 22 78 00Fax +46 (0) 40 94 99 [email protected]

Dokument 1 20.09.2002 11:02 Uhr Seite 2