SHIP SURVEY STATUS
SENTINEL
Gross Tonnage 2408
Ship Type PASSENGER/GENERAL CARGO
30/06/1982Date of Build
IMO Number 8020159
05244IR Number
Survey Status Generated on 05/01/2017
ANDAMAN & NICOBAR ADMRegistered Owner :
:
:
:
:
:
:
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 2 / 25
Table of Contents
Ship Particulars
Owner / Manager Information
Class / Statutory, ISM, ISPS, MLC Certificates
Survey / Audit / Inspection Status
Condition of Class
Additional Information
Continuous Survey List(s)
List of Surveyable Items
Survey History - 5 Year Survey Cycle
Compliance to New Regulations
IRCLASS Contacts
Statutory Condition
Memoranda
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 3 / 25
Ship Particulars
IdentificationPASSENGER/GENERAL CARGOShip Type INDIANFlag
MumbaiPort of Registry
Date of Registry
Classification
SUL, PASSENGER SHIPClass Notation Hull
IYClass Notation Machinery
Hull2408Gross Tonnage Mazagon Dock Ltd.Builder
722Net Tonnage MUMBAIPlace of Built
1472 tonDeadweight
81.32 mOverall Length
74 mLBP
14.4 mBreadth
4.11 mDraught
Class History
Suspended
Classed
Suspended
Re-instated
Suspended
Re-instated
01/03/1997
28/03/1997
01/03/2001
30/07/2001
01/03/2002
15/07/2002
28/03/1997
01/03/2001
30/07/2001
01/03/2002
15/07/2002
Survey Overdue
-
Survey Overdue
Re Instated
Survey Overdue
Re Instated
SRVYS O/D
CLASS NOW BY CSG
SURVEYS O/D
SURVEYS DONE
SURVEYS O/D
SURVEYS DONE
Ship Status : From Date : To Date : Reason : Remarks :
580Yard No.
1946Official No
VTFGCall Sign
Registered under: - For Indian Flag
30/06/1982Date of Build 1478TLight Ship
:
:
:
:
:
:
:
:
:
::::
::::
::::
Keel Date 29-NOVAnniversary Date : :Building Contract Date :Major Conversion Date :
3207 mmFreeboard : :P Equipment Ltr :
: and Chain Dia. 48 mmChain Quality Type
7.3 mDepth
: 183.12 m³Ballast Water Capacity
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 4 / 25
Machinery
450 mmStroke
Garden Reach Shipbuilders & Engineers Ltd. Ranchi
Engine Builder
31/08/1981Engine built
Propeller
1560 kWTotal power
G5V 30/45 ATLMain Engine Model
300 mmBore :
:
:
:
:
:12 KnotsSpeed : 146RPM :
Boilers :
Electrical Installation
: 3 Diesel Generators of Kirloskar Oil Engine Ltd., Power : 212 KW each 440V, 50Hz; Model : W6V BSLM
:
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 5 / 25
Manager THE SHIPPING CORPORATION OF INDIA LTD.,Name
Shipping House, 245 , Madame Cama Road,Nariman Point,400021,Mumbai , IndiaPin Code:400021Phone:2026666Fax:2022949Email:[email protected]
Address
Invoicing Address SHIPPING CORPORATION OF INDIA LTD.Name
Shipping House , 13,Strand RoadCalcutta , West BengalIndiaPin Code:700001
Address
Manager ISM / ISPS / MLC THE SHIPPING CORPORATION OF INDIA LTD.Name
Shipping House245 , Madame Cama RoadNariman PointMumbai - 400 021India
Address
Owner /Manager Information
Registered Owner
ANDAMAN & NICOBAR ADMName
Directorate Of Shipping ServicesPort Blair , Union TerritoryIndiaPin Code:744 101Phone:03192-30435/240486Fax:03192-230480
Address
:
:
:
:
:
:
:
:
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 6 / 25
Class / Statutory, ISM, ISPS, MLC Certificates
Certificate name Expiry Date Cert. TypeIssued Date
The Class / Statutory, ISM, ISPS, MLC Status below shows the information available in IRCLASS database at the time the status is printed. This may not indicate certificates issued, surveys carried out or recommendations issued but not yet reported to Head Office.
Class Certificate
Statutory Certificate
International Loadline Certificate
Statutory Audits / Inspections
ISPS Code Certificate
Safety Management Certificate ()
29/11/2017
29/11/2017
24/04/2021
29/09/2018
FT
FT
FT
FT
19/02/2013
19/02/2013
27/04/2016
18/02/2014
Note : Cert. Type - FT = Full Term, ST = Short Term, ET= Extended Term , INT = Interim
IRS
IRS
GOI
GOI
Issued By
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 7 / 25
Statutory Certificates Status Range Dates
Survey Name Assigned Date Due Date StatusRange Date
Last Survey Date
Status
International Loadline Certificate International Loadline Certificate Annual
28/02/201708/06/2016
Surveys / Audits / Inspections StatusClassification Surveys
Statutory Surveys
Statutory Certificates Status Range DatesLast Audit Date
Status
SMC Intermediate : completed on 08-JAN-14
ISPS Code Certificate (Coastal) (Full Term)ISPS Code Certificate Intermediate Audit
Safety Management Certificate (Full Term)Safety Management Certificate(SMC) Renewal Audit
24/04/2019
29/09/2018
27/02/2016
08/01/2014
Statutory Audits / Inspections
Previously done on 13/09/2012
Intermediate Survey ( Complete ) 26/06/2015
Continuous Survey Hull
Intermediate Survey
Annual Survey
Docking Survey
Continuous Survey Machinery
Tailshaft (oil gland), Port
Tailshaft (oil gland), Starboard
30/11/2012
08/06/2016
02/06/2015
30/11/2012
13/09/2012
13/09/2012
29/11/2017
29/11/2016
29/11/2017
12/09/2017
12/09/2017
29/08/2016
29/11/2017
28/02/2017
29/11/2017
12/09/2017
12/09/2017
To
IRS
Survey Carried Out By
IRS
IRS
Audit Carried OutBy
29/11/2017 29/11/2017Renewal Docking Survey
29/08/2016 -
24/04/2018
29/06/2018
-
-
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 8 / 25
Statutory Condition
Memoranda*** No Statutory Condition Recommended ***
*** No Memoranda Recommended ***
Condition of Class
Overdue Condition Of Class
Additional Information
Locally Wasted/corroded main deck plating (1st inboard strake) bet fr 24 & 27(S) IWO officers galley now temporarily repaired(doubled up). Same to be dealt with by the due date.
Doubled up 1st deck below main deck plating IWO centre line bet fr 90 & 92 to be dealt with by the due date.
Vessel is LRIT Compliant.
Vessel provided with an Emergency Towing Arrangements / procedures required by SOLAS Reg. 3-4.2 of Chapter II-1.
Special Survey requirements eg. Thickness Measurement, Examination/Testing of Bilge & Ballast pipe line to working pressure etc. to be carried out during or after 4th Annual Survey. For vessels more than 10 yrs of age, the ballast tanks are to be internally examined twice in each 5 year class period.
Sewage holding tank , pumping and piping arrangement installed as per IRS approved plan no: IMC/SCI/000-A ,dated: 12/05/2009 during vessel lay up at Colombo in July 2010.
Existing 03 nos Aux. Engine Sets(including alternators) replaced with new Nox compliant Aux. Engine Sets (including alternators) in July 2010.
Stbd tail shaft now renewed at visakhapatnam on 09/2012
Rudders pintle clearances (09/2012) as follows.Rudder (Port): Fwd - Aft: 2.8mm, Port - Stbd: 3.85mmRudder(Stbd): Fwd - Aft : 2.7mm; Port - Stbd :2.9mm
Rudders pintle clearances (06/2015) as follows.Rudder (Port): Fwd - Aft: 2.82mm, Port - Stbd: 3.87mmRudder(Stbd): Fwd - Aft : 2.73 mm; Port - Stbd :3.0mm
TS(OG) poker gauge readings(11/2010):Port 3.90mm,stbd 3.80mm and now (09/2012) : Port: 3.95 mm,Stbd: 3.8mm ;Port Tail
H0704
H0705
MA0502.
HA0606.
HA0601.
HA0608.
MA0604.
MA0605.
HA0609.
MA0603.
PRB16P007/PRB/
PRB16P007/PRB/
PRB10P013/PRB/
PRB10P073/PRB/
VKM12P022/VKM/
COL10P022/COL/
COL10P022/COL/
VKM12P022/VKM/
CAL15P033/CAL/
CAL15P033/CAL/
08/06/2016
08/06/2016
27/04/2010
01/06/2011
02/01/2013
15/07/2010
15/07/2010
02/01/2013
26/06/2015
26/06/2015
08/06/2016
08/06/2016
15/07/2010
15/07/2010
02/01/2013
05/08/2010
PRB16P007/PRB/
PRB16P007/PRB/
COL10P022/COL/
COL10P022/COL/
VKM12P022/VKM/
COL10P022/COL/
KSAT
KSAT
DKG
LS
PMR
AADA
AADA
PMR
AKT
AKT
KSAT
KSAT
LS
LS
PMR
RACR
AADA
AKT
AKT
Mod
Mod
Asgn
Asgn
Code
Code
Previous Reference
Previous Reference
Prev Ref Dt
Prev Ref Dt
Current Reference
Current Reference
Curr Ref Dt
Curr Ref Dt
29/11/2016
29/11/2016
Due Date
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 9 / 25
Shaft Clearance: 0.55 mm, stbd tail shaft clearance:0.55 mm
TS(OG) poker gauge readings(03/2015): Port - 45.4 mm, 47.1 mm.
As per GOI Rules Dry Docking surveys are to be carried out Annually.
04 nos. full length shackle and one swivel adaptor of Stbd anchor chain cable renewed with IRS certified (Cert. no.CAL15C196) spares.
On or after 1 January 2018, the discharge of sewage from within a special area is prohibited except when the ship has in operation an approved (as per MEPC.227(64) including the standards of section 4.2 in respect of Nitrogen and Phosphorus removal standard) sewage treatment plant which has been certified by the Administration to meet the operational requirements referred to in Marpol Annex IV/Reg. 9.2.1 of this Annex, and the effluent does not produce visible floating solids nor cause discoloration of the surrounding water.
Upon completion of the first tail shaft survey scheduled on or after 1 Jan 2016, new tailshaft survey notation as per Class Rulerequirement (Rule change notice No.2 - Jan 2016) is to be recommended for assignment.An additional information is to be recommended providing date of withdrawal of the tail shaft, type of survey performed, type ofpropeller connection, tailshaft survey method (as per changes to rule requirement) which may be applied at the next tailshaft survey with due date.
High frequency(HF) radio-communications equipment capable of operating narrow-band direct printing(NBDP), if fitted, to be updated to meet the new channeling arrangements contained in the 2012 Radio Regulations HF, Appendix 17, Part B, SectionII & III (HF Direct-printing telegraphy) by the first safety radio survey after 1 January 2024.
Revised format of the Passenger Ship Safety Certificate adopted through IMO Res. MSC. 395(95) is to be issued to the vesselat first survey on or after 1 January 2017.
All W.B tanks to be examined annually until coating made good..
The vessel being a Passenger ship all statutory surveys / certification except Loadline are done / issued by Flag Administration.
-05HA.
HA0711.
MA0706.
MA0707.
MA0708.
HA0712.
-04HA.
HA0713.
CAL15P033/CAL/
CAL15P033/CAL/
IT ADDLNOTE07112015
IT ADDLNOTE19012016A
IT ADDLNOTE11052016
IT ADDLNOTE08062016F
PRB16P007/PRB/
PRB16P050/PRB/
26/06/2015
26/06/2015
07/11/2015
19/01/2016
11/05/2016
08/06/2016
08/06/2016
31/07/2016
08/01/2002
09/07/2015
02/08/2016
CAL15P033/CAL/
PRB16P050/PRB/
AKT
AKT
PGM
SMA
SMA
SMA
KSAT
RAA
AKT
AKT
PGM
SMA
SMA
SMA
KSAT
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 10 / 25
Compliance to New Regulations:
Z0602.
Z0704.
Lifeboat on-load release mechanisms not complying with paragraphs 4.4.7.6.4 to 4.4.7.6.6 of the LSA Code as amended by resolution MSC.320(89) are required to be replaced or modified (as detailed in MSC.1/Circ.1392 - Guidelines for Evaluation and Replacement of Lifeboat Release and Retrieval Systems) not later than the first scheduled dry-docking after 1st July 2014, but not later than 1st July 2019.Appropriate portable atmosphere testing instrument/s (as a minimum capable of measuring concentrations of oxygen, flammable gases or vapours, hydrogensulphide and carbon monoxide) will be required (SOLAS Ch.XI-1 Reg.7) to be carried on board from 01/07/2016. Instruments carried under other requirements may satisfy this regulation. Suitable means shall be provided for the calibration of all such instrument/s.
31/07/2016 PRB16P050/PRB/
Code Description Date Complied With Report Reference
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 11 / 25
Continuous Survey List(s)
1300
1317
1324
Electrical SystemPort Gen.& Governor Running Test
Centre Gen.& Governor Running Test
Stbd Gen.& Governor Running Test
29/12/2012
29/12/2012
29/12/2012
08/03/2017
08/03/2017
08/03/2017
0316
0323
0330
0347
0354
0361
0378
0385
0392
0402
0419
0426
0433
0440
0457
0464
0471
0488
0495
0505
0512
0529
0536
0543
0550
0567
Stbd Inline Trunk Piston Type EngineNo.1 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & Gears
No.2 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & Gears
No.3 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & Gears
No.4 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & Gears
No.5 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & Gears
No.1 Main Journal & Bearing
No.2 Main Journal & Bearing
No.3 Main Journal & Bearing
No.4 Main Journal & Bearing
No.5 Main Journal & Bearing
No.6 Main Journal & Bearing
No.1 O.F Inj.Pump,H.P O.F Pipes & Shielding
No.2 O.F Inj.Pump,H.P O.F Pipes & Shielding
No.3 O.F Inj.Pump,H.P O.F Pipes & Shielding
No.4 O.F Inj.Pump,H.P O.F Pipes & Shielding
No.5 O.F Inj.Pump,H.P O.F Pipes & Shielding
Engine Trial
Crankcase Doors & Relief Devices
Crankshaft Alignment
Camshaft/s & Camshaft/s Drive
Bed Plates,Frames,Tie Rods,Holding Down Bolts & Chocks
Super Charger
Main Engine Air Cooler
Main Engine Attached Sea Water Cooling Pump
Main Engine Attached Fresh Water Cooling Pump
Main Engine Attached Lub.Oil Circulating Pump
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
Code Assigned Date*** Items Due Next 12 Months *** Due Date
Code *** Items Due Next 6 Months *** Assigned Date Due DatePostponement
Date
PostponementDate
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 12 / 25
0574
0581
0749
0756
0763
0787
0794
0804
0873
0938
0969
0983
1001
1018
1049
1070
1087
1094
1128
1135
1166
1180
1197
1348
1362
1379
1386
Main Engine Attached O.F Booster Pump
Coupling
Port Shafting ArrangementFwd Intermediate Shaft & Bearing/s
Centre Intermediate Shaft & Bearing/s
Aft Intermediate Shaft & Bearing/s
Stbd Shafting ArrangementFwd Intermediate Shaft & Bearing/s
Centre Intermediate Shaft & Bearing/s
Aft Intermediate Shaft & Bearing/s
Auxiliary MachineryStbd Steering Gear Machinery Unit
Compressed Air SystemEmerg.Air Comp.Incl.Cooler,Safety Devices & Engine
Inner Aux.Air Receiver & Safety Devices
Starting Air Pipes & Valves
Fuel SystemD.O Transfer Pump
O.F Pipes/Valves/Filters
Lub.Oil SystemStbd Main Engine Lub.Oil Pump
Stbd Main Engine Lub.Oil Cooler
Main Engine Scavenge Lub.Oil Pump
Lub.Oil Pipes/Valves/Filters
Cooling SystemGear Box Sea Water Cooling Pump
Sea Water Pipes/Valves/Filters
Stbd Main Engine Fresh Water Cooler
Stbd Fuel Valve Fresh Water Cooler
Fresh Water Pipes/Valves/Filters
Electrical SystemEmerg.Source Of Power & Associated Equipment
Cables/Expansion Boxes/Fittings Etc.
Circuit Breakers
Motor/s,Control/s & Starter/s
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
Code Assigned Date*** Items Due Next 12 Months *** Due Date
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 13 / 25
1393
5366
5373
5421
5438
5452
5469
5548
5555
5579
5586
5634
5641
5665
5672
5720
5737
5751
5768
5878
5885
5902
5919
6020
Transformer/s
No.2 F.W Double Bottom TankExamination
Test
No.4 Port F.W Double Bottom TankExamination
Test
No.5 Stbd F.W Double Bottom TankExamination
Test
No.7 Port F.W Double Bottom TankExamination
Test
No.8 Stbd F.W Double Bottom TankExamination
Test
No.10 Port F.W Double Bottom TankExamination
Test
No.11 Stbd F.W Double Bottom TankExamination
Test
No.13 Port D.O Double Bottom TankExamination
Test
No.14 Stbd D.O Double Bottom TankExamination
Test
No.18 Centre D.O Double Bottom TankExamination
Test
No.19 Port D.O Double Bottom TankExamination
Test
No.23 Centre D.O Double Bottom TankExamination
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
Code Assigned Date*** Items Due Next 12 Months *** Due Date
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 14 / 25
6037
6116
6123
6147
6154
6178
6185
6202
6219
6226
6257
Test
No.25 Centre Double Bottom TankExamination
Test
No.28 Stbd Dirty Oil TankExamination
Test
No.29 Stbd Sludge TankExamination
Test
No.30 Port Dirty Oil TankExamination
Test
Shaft Tunnel
Electromagnetic Log Transdveres Compartment
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
29/12/2012
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
28/12/2017
Code Assigned Date*** Items Due Next 12 Months *** Due Date
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 15 / 25
0017
0309
5
5
Port Inline Trunk Piston Type Engine
Stbd Inline Trunk Piston Type Engine
29
58
0024003100480055006200790086009301030110012701340141015801650172018901960206021302200237024402510268027502820299
03160323033003470354036103780385
5555555555555555555555555555
55555555
06/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/201606/2016
12/201212/201212/201212/201212/201212/201212/201212/2012
No.1 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & GearsNo.2 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & GearsNo.3 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & GearsNo.4 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & GearsNo.5 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & GearsNo.1 Main Journal & BearingNo.2 Main Journal & BearingNo.3 Main Journal & BearingNo.4 Main Journal & BearingNo.5 Main Journal & BearingNo.6 Main Journal & BearingNo.1 O.F Inj.Pump,H.P O.F Pipes & ShieldingNo.2 O.F Inj.Pump,H.P O.F Pipes & ShieldingNo.3 O.F Inj.Pump,H.P O.F Pipes & ShieldingNo.4 O.F Inj.Pump,H.P O.F Pipes & ShieldingNo.5 O.F Inj.Pump,H.P O.F Pipes & ShieldingEngine TrialCrankcase Doors & Relief DevicesCrankshaft AlignmentCamshaft/s & Camshaft/s DriveBed Plates,Frames,Tie Rods,Holding Down Bolts & ChocksSuper ChargerMain Engine Air CoolerMain Engine Attached Sea Water Cooling PumpMain Engine Attached Fresh Water Cooling PumpMain Engine Attached Lub.Oil Circulating PumpMain Engine Attached O.F Booster PumpCoupling
No.1 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & GearsNo.2 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & GearsNo.3 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & GearsNo.4 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & GearsNo.5 Cyl,Cvr,Pstn,Con Rod,C.Pin Brg & Webs,Vlvs & GearsNo.1 Main Journal & BearingNo.2 Main Journal & BearingNo.3 Main Journal & BearingNo.4 Main Journal & Bearing
05/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/202105/2021
12/201712/201712/201712/201712/201712/201712/201712/2017
List of Surveyable Items
List Of Machinery Items...
Status Cycle Date DescriptionCode Next Due
DatePostpone
Date
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 16 / 25
0598
0660
0732
0770
5
5
5
5
Port Main Reduction Gearing
Stbd Main Reduction Gearing
Port Shafting Arrangement
Stbd Shafting Arrangement
65
72
76
80
03920402041904260433044004570464047104880495050505120529053605430550056705740581
060806150622063906460653
067706840691070107180725
074907560763
0787
55555555555555555555
555555
555555
555
5
12/201212/201212/201212/201212/201212/201212/201212/201212/201212/201212/201212/201212/201212/201212/201212/201212/201212/201212/201212/2012
06/201606/201606/201606/201606/201606/2016
06/201506/201506/201506/201506/201506/2015
12/201212/201212/2012
12/2012
No.5 Main Journal & BearingNo.6 Main Journal & BearingNo.1 O.F Inj.Pump,H.P O.F Pipes & ShieldingNo.2 O.F Inj.Pump,H.P O.F Pipes & ShieldingNo.3 O.F Inj.Pump,H.P O.F Pipes & ShieldingNo.4 O.F Inj.Pump,H.P O.F Pipes & ShieldingNo.5 O.F Inj.Pump,H.P O.F Pipes & ShieldingEngine TrialCrankcase Doors & Relief DevicesCrankshaft AlignmentCamshaft/s & Camshaft/s DriveBed Plates,Frames,Tie Rods,Holding Down Bolts & ChocksSuper ChargerMain Engine Air CoolerMain Engine Attached Sea Water Cooling PumpMain Engine Attached Fresh Water Cooling PumpMain Engine Attached Lub.Oil Circulating PumpMain Engine Attached O.F Booster PumpCoupling
Pinion/s & Wheel/sShaft/s Coupling/s,Clutch(es) & Bearing/sThrustAttached Lub.Oil PumpAttached Lub.Oil CoolerFoundation Bolts & Chocks
Pinion/s & Wheel/sShaft/s Coupling/s,Clutch(es) & Bearing/sThrustAttached Lub.Oil PumpAttached Lub.Oil CoolerFoundation Bolts & Chocks
Fwd Intermediate Shaft & Bearing/sCentre Intermediate Shaft & Bearing/sAft Intermediate Shaft & Bearing/s
Fwd Intermediate Shaft & Bearing/s
12/201712/201712/201712/201712/201712/201712/201712/201712/201712/201712/201712/201712/201712/201712/201712/201712/201712/201712/201712/2017
06/202106/202106/202106/202106/202106/2021
04/202004/202004/202004/202004/202004/2020
12/201712/201712/2017
12/2017
Status Cycle Date DescriptionCode Next Due
DatePostpone
Date
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 17 / 25
0811
0907
0990
1025
1104
5
5
5
5
5
Auxiliary Machinery
Compressed Air System
Fuel System
Lub.Oil System
Cooling System
89
98
101
109
119
07940804
08280835084208590866087308800897
09140921093809450952096909760983
10011018
1032104910561063107010871094
1111112811351142115911661173
55
55555555
55555555
55
5555555
5555555
12/201212/2012
06/201506/201506/201506/201507/201612/201206/201506/2016
06/201506/201612/201206/201506/201612/201206/201512/2012
12/201212/2012
06/201612/201206/201506/201612/201212/201212/2012
02/201512/201212/201206/201506/201612/201206/2016
Centre Intermediate Shaft & Bearing/sAft Intermediate Shaft & Bearing/s
Port Generator Aux.Engine With Attachments & CoolersCentre Generator Aux.Engine With Attachments & CoolersStbd Generator Aux.Engine With Attachments & CoolersEmerg.Gen.Engine With Attachments & CoolersPort Steering Gear Machinery UnitStbd Steering Gear Machinery UnitWindlass Machinery UnitFirst Start Arrangement Trial
Port Starting Air Comp.Incl.Cooler & Safety DevicesStbd Starting Air Comp.Incl.Cooler & Safety DevicesEmerg.Air Comp.Incl.Cooler,Safety Devices & EngineInner Starting Air Receiver & Safety DevicesOuter Starting Air Receiver & Safety DevicesInner Aux.Air Receiver & Safety DevicesOuter Aux.Air Receiver & Safety DevicesStarting Air Pipes & Valves
D.O Transfer PumpO.F Pipes/Valves/Filters
Port Main Engine Lub.Oil PumpStbd Main Engine Lub.Oil PumpGear Box Standby PumpPort Main Engine Lub.Oil CoolerStbd Main Engine Lub.Oil CoolerMain Engine Scavenge Lub.Oil PumpLub.Oil Pipes/Valves/Filters
Main Sea Water Cooling PumpGear Box Sea Water Cooling PumpSea Water Pipes/Valves/FiltersMain Engine Fresh Water Cooling PumpPort Main Engine Fresh Water CoolerStbd Main Engine Fresh Water CoolerPort Fuel Valve Fresh Water Cooler
12/201712/2017
06/202006/202006/202006/202007/202112/201706/202006/2021
06/202006/202112/201706/202006/202112/201706/202012/2017
12/201712/2017
06/202112/201704/202005/202112/201712/201712/2017
08/201912/201712/201706/202005/202112/201705/2021
Status Cycle Date DescriptionCode Next Due
DatePostpone
Date
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 18 / 25
1207
1290
1410
5
5
5
Bilge & Ballast System
Electrical System
Sea Connections
128
140
145
11801197
12141221123812451252126912761283
13001317132413311348135513621379138613931403
1427143414411458
55
55555555
55555555555
5555
12/201212/2012
06/201606/201606/201606/201602/201506/201606/201606/2016
12/201212/201212/201206/201512/201206/201612/201212/201212/201212/201206/2015
06/201506/201506/201506/2015
Stbd Fuel Valve Fresh Water CoolerFresh Water Pipes/Valves/Filters
Bilge PumpFire/G.S PumpEmergency Bilge PumpEmergency Fire Pump & Prime MoverFire/G.S Pump In Aux.E.RWorking Test Of Bilge System Incl.Emerg.SuctionBilge Pipes/Valves/FiltersBallast Pipes/Valves/Filters
Port Gen.& Governor Running TestCentre Gen.& Governor Running TestStbd Gen.& Governor Running TestSwitch Boards & FittingsEmerg.Source Of Power & Associated EquipmentNavigation Lights,IndicatorsCables/Expansion Boxes/Fittings Etc.Circuit BreakersMotor/s,Control/s & Starter/sTransformer/sMegger Test
Port Side SuctionsPort Side DischargesStbd Side SuctionsStbd Side Discharges
12/201712/2017
06/202106/202106/202105/202108/201906/202106/202106/2021
03/201703/201703/201706/202012/201706/202112/201712/201712/201712/201706/2020
06/202006/202006/202006/2020
List Of Hull Items...
5012
5029
5036
5043
5050
5067
5074
5081
5
5
5
5
5
5
5
5
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
Thickness Determination
Bridge Superstructure
Upr Deck Plating
Second Deck Plating
Winch Island
Cattle Pen
Bunk Passenger Accomodation Space
Second Class Unberthed Passenger Space
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
Status Cycle Date DescriptionCode Next Due Date
Status Cycle Date DescriptionCode Next Due
DatePostpone
Date
PostponeDate
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 19 / 25
5098
5108
5115
5122
5139
5146
5153
5160
5177
5201
5232
5263
5294
5328
5359
5380
5414
5445
5476
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
Baggage Room
Provision Store
Engine Room
Chain Locker
Aux.Engine Room
No.1 Hold
No.2 Hold
Fwd Void Space
Forepeak Tank
Aftpeak Tank
No.31 Stbd D.O Storage Tank
No.32 Port D.O Daily Service Tank
No.33 Port D.O Daily Service Tank
No.34 Port D.O Daily Service Tank
No.2 F.W Double Bottom Tank
No.3 W.B Double Bottom Tank
No.4 Port F.W Double Bottom Tank
No.5 Stbd F.W Double Bottom Tank
No.6 Port W.B Double Bottom Tank
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
5184
5191
5218
5225
5249
5256
5270
5287
5304
5311
5335
5342
5366
5373
5397
5407
5421
5438
5452
5469
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
12/2012
12/2012
06/2015
06/2015
12/2012
12/2012
12/2012
12/2012
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
12/2017
12/2017
06/2020
06/2020
12/2017
12/2017
12/2017
12/2017
Status Cycle Date DescriptionCode Next Due DatePostpone
Date
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 20 / 25
5500
5531
5562
5593
5627
5658
5689
5713
5744
5775
5809
5830
5861
5
5
5
5
5
5
5
5
5
5
5
5
5
No.6 Stbd W.B Double Bottom Tank
No.7 Port F.W Double Bottom Tank
No.8 Stbd F.W Double Bottom Tank
No.9 W.B Double Bottom Tank
No.10 Port F.W Double Bottom Tank
No.11 Stbd F.W Double Bottom Tank
No.12 W.B Double Bottom Tank
No.13 Port D.O Double Bottom Tank
No.14 Stbd D.O Double Bottom Tank
No.15 Port L.O Double Bottom Sump
No.16 Stbd L.O Double Bottom Sump
No.17 W.B Double Bottom Tank
No.18 Centre D.O Double Bottom Tank
5483
5490
5517
5524
5548
5555
5579
5586
5603
5610
5634
5641
5665
5672
5696
5706
5720
5737
5751
5768
5782
5799
5816
5823
5847
5854
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
06/2015
06/2015
06/2015
06/2015
12/2012
12/2012
12/2012
12/2012
06/2015
06/2015
12/2012
12/2012
12/2012
12/2012
06/2015
06/2015
12/2012
12/2012
12/2012
12/2012
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
06/2020
06/2020
06/2020
06/2020
12/2017
12/2017
12/2017
12/2017
06/2020
06/2020
12/2017
12/2017
12/2017
12/2017
06/2020
06/2020
12/2017
12/2017
12/2017
12/2017
04/2020
04/2020
06/2020
04/2020
06/2020
06/2020
Status Cycle Date DescriptionCode Next Due DatePostpone
Date
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 21 / 25
5892
5926
5957
5988
6013
6044
6075
6109
6130
6161
6192
6226
6233
6240
6257
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
12/2012
06/2015
06/2015
12/2012
No.19 Port D.O Double Bottom Tank
No.20 Stbd D.O Double Bottom Tank
No.21 Port D.O Double Bottom Tank
No.22 Stbd D.O Double Bottom Tank
No.23 Centre D.O Double Bottom Tank
No.24 Port W.B Double Bottom Tank
No.24 Stbd W.B Double Bottom Tank
No.25 Centre Double Bottom Tank
No.28 Stbd Dirty Oil Tank
No.29 Stbd Sludge Tank
No.30 Port Dirty Oil Tank
Shaft Tunnel
Under Engines
Echo Sounding Compartment
Electromagnetic Log Transdveres Compartment
12/2017
06/2020
06/2020
12/2017
5878
5885
5902
5919
5933
5940
5964
5971
5995
6006
6020
6037
6051
6068
6082
6099
6116
6123
6147
6154
6178
6185
6202
6219
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
12/2012
12/2012
12/2012
12/2012
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
12/2012
12/2012
06/2015
06/2015
06/2015
06/2015
12/2012
12/2012
12/2012
12/2012
12/2012
12/2012
12/2012
12/2012
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
Examination
Test
12/2017
12/2017
12/2017
12/2017
06/2020
04/2020
04/2020
04/2020
04/2020
04/2020
12/2017
12/2017
06/2020
06/2020
06/2020
06/2020
12/2017
12/2017
12/2017
12/2017
12/2017
12/2017
12/2017
12/2017
Status Cycle Date DescriptionCode Next Due DatePostpone
Date
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 22 / 25
4011
4073
5
5
Port Tailshaft Survey
Stbd Tailshaft Survey
40284035404240594066
55555
09/201209/201209/201209/201209/2012
Crack Detection Of Screw Shaft ConeApproved Oil GlandPropellerTailshaftSternbush
Crack Detection Of Screw Shaft Cone
List Of Other Items...
6264
6271
6288
6295
6305
6312
6329
6336
6343
6350
6367
6374
6415
6422
6439
6446
6453
6460
6477
6484
6491
6501
6518
6525
6532
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
06/2015
Windlass
Anchors/s
Cables
Steering Gear
Aux.Steering Gear
Hand Pump/s
Sounding Pipes
Air Pipe/s
Mast/s
Rigging
Fire Equipment
Means Of Escape
Communication-Bridge To Engine Room
Communication-Bridge To Alternative Steering Position
Helm Indicator
Hatchways & Closing Appliances
Ventilators,Airpipes & Closing Appliances
Casings & Their Closing Appliances
Deckhouses,Companionways & Closing Appliances
Superstructures & Closing Appliances
Windows,Side Scuttles,Deadlights & Closing Appliances
Scuppers,Sanitary Discharges & Valves
Guard Rails & Bulwarks
Freeing Ports
Gangways,Walkways & Lifelines
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
06/2020
6381
6398
6408
5
5
5
06/2015
06/2015
06/2015
Machinery Space
Crew & Passenger Spaces
Spaces In Which Crew Employed
06/2020
06/2020
06/2020
Code Status Cycle Date Description
Status Cycle Date DescriptionCode Next Due DatePostpone
Date
PostponeDate
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 23 / 25
408040804097410741144121
555555
11/201009/201209/201209/201209/201209/2012
Crack Detection Of Screw Shaft ConeApproved Oil GlandPropellerTailshaftSternbush
Code Status Cycle Date DescriptionPostpone
Date
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 24 / 25
Survey History - 5 Year Cycle
PRB16P055
PRB16P050
PRB16P043
PRB16P007
PRB16P004
PRB15P055
CAL15P033
PRB14P040
PRB14P004
PRB13P036
PRB13P035
PRB13P012
VKM12P022
PRB16P078
17/08/2016
31/07/2016
19/07/2016
08/06/2016
17/02/2016
26/12/2015
26/06/2015
13/02/2015
16/04/2014
19/07/2013
21/06/2013
21/03/2013
29/12/2012
COC(M)
CSM
DAMM
AS,COC(M),CSM,GEFSI,ILLAS,REH
GEFSI
DAMM
AS,COC(H),CSH,CSM,DS,ILLAS,IS
COC(H),CSM
AS,ILLAS
COC(M),DAMH
COC(M)
COC(M)
AS,COC(M),CSH,CSM,DS,ILLRS,REH,TS(OG)p,TS(OG)s
DAMH
Survey Station
Survey Station
Report Number
Report Number
Last Visit Date
Last Visit Date
Survey Held
Survey Held
***List of Reports under survey(Last visit not yet marked)***
17/08/2016
28/07/2016
19/07/2016
29/02/2016
15/02/2016
26/12/2015
27/02/2015
12/07/2014
13/01/2014
02/07/2013
21/06/2013
21/03/2013
04/02/2012
18/12/2016
First Visit Date
First Visit Date
PORT BLAIR
PORT BLAIR
PORT BLAIR
PORT BLAIR
PORT BLAIR
PORT BLAIR
KOLKATA
PORT BLAIR
PORT BLAIR
PORT BLAIR
PORT BLAIR
PORT BLAIR
VIZAG
PORT BLAIR
IR CLASSSHIP SURVEY STATUS
For any enquiries please contact : IRCLASSTelephone: 022 - 30519400, 71199400E-Mail: [email protected] fax line: 022 25703611www.irclass.orgSurvey status generated on: 05/01/2017 06:32 PM
SENTINEL
In Operation, Class Valid
Name
Status
05244
8020159
IR Number
IMO Number
Survey Status Report
:
:
:
:
Page 25 / 25
Ships In Service Division52A, Adishankaracharya Marg,
Opp Powai Lake, Powai, Mumbai,Maharashtra, India-400072.
Tel.: 91 22 30519400, 71199400 (0) Fax: 91 22 25703611Corporate website: www.irclass.org
Email: [email protected]
IRCLASS Contacts
DISCLAIMER :-
Information provided in ship survey status by IRClass is solely provided for the convenience of Owners or Managers as a guide to their ship's survey status and in no way substitute for advice from IRClass.
Neither Indian Register of Shipping, nor any of its employees, assures any responsibility for the accuracy or legal liability for any loss or damage that may be sustained as a result of using their services.