The intellectual manifestation of this drawing and its Revit file generated origin is subject to Global copyright. Its use is subject to the approval of its owners and authors under license for implementation of a construction process specfic to a single site and location. Reproduction and/or use of it, in full or part, for any other purpose without the written approval of its owners and authors is illegal and and subject to prosecution. www.lapl.com.au [email protected] 864 146
Project Number Project Name
Sheet Name
Address
Drawings produced in Autodesk Revit. Noted dimensions shall be taken in preference to scaling. Do not scale or dimension by hand. Verify all dimensions on site prior to construction or quote. Upon receipt of updated pans, discard previous versions. at A3Scale: at A1 23/06/2021 12:26:36 PM
Heywood Mobil Pegasus
Mobil Pegasus
3013 Henty Highway, Heywood 3304
A0.01 Cover Index Render
326
Sheet List
SheetNumber Sheet Name
CurrentRevision
A0.01 Cover Index Render AA0.02 Feature SurveyA1.01 Site Plan CA1.01b Swept Paths Analysis for original
Planning Permit P19158A1.02 Floor Plan AA1.03 Reflected Ceiling Plan RCPA1.04 Roof PlanA2.01 Elevations 1 - E W BA2.02 Elevations 2 - N S BA6.02 Door Window Schedule
Revision Description DateA Added Sheets A1.04 Roof Plan, A6.01 Building Signage, A6.02 Door
Window Schedule. Bowser added to Truck Canopy26/02/21
Version: 1, Version Date: 02/07/2021Document Set ID: 2864932
LEGENDNOTATIONS
Print Date
PRELIMINARY
The intellectual manifestation of this drawing and its Revit file generated origin is subject to Global copyright. Its use is subject to the approval of its owners and authors under license for implementation of a construction process specfic to a single site and location. Reproduction and/or use of it, in full or part, for any other purpose without the written approval of its owners and authors is illegal and and subject to prosecution. www.lapl.com.au [email protected] 864 146
Project Number Project Name
Sheet Name
Address
Drawings produced in Autodesk Revit. Noted dimensions shall be taken in preference to scaling. Do not scale or dimension by hand. Verify all dimensions on site prior to construction or quote. Upon receipt of updated pans, discard previous versions. at A3Scale: 1 : 750 at A1 23/06/2021 12:26:48 PM
Heywood Mobil Pegasus
Mobil Pegasus
3013 Henty Highway, Heywood 3304
A0.02 Feature Survey
326
1 : 750Feature Survey
1
0
SCALE 1:
37.5
750
3022.5157.57.5
mRevision Description Date
Version: 1, Version Date: 02/07/2021Document Set ID: 2864932
P.1 P.2 P.4
P.A
P.C
P.D
P.G
P.5 P.7
T.1T.3T.4T.5
T.A
T.B
T.C
T.D
P.B
C.A
C.B
C.2C.1
S.B
P.F
P.E
2000800080002000
TruckFuel
Canopy
CarFuel
Canopy
1000
0
9010
2000 5500 5500 2000
Can
opy
line
over
Awni
ngov
er
S.A
Filler Point
1500
1:10
Bin Store/Service Yard
TYP2600
Convenience Store360.1m2
Can
opy
line
over
Princ
es H
ighwa
y
Henty Highway
6000
600
1173
0
2900
3150
3950 8000
5500
2150
9000
7480 6000 2395
2050
2000
6910
23775
5000
Land
scap
ing
Landscaping
Landscaping
A2.01
1
A2.02 2
A2.01
2
A2.021
ATU
12m High Pylon Sign
T.2
1000
10m High Pylon Sign
50000
5000
0
Proposed Cyclone Mesh Fence
Waste Water Management Disposal Zone
5077m2
LPG Filler Point
Indicative location of above ground 2x7.5kL LPG Tank
80000
INDICATIVE LOCATION OF UNDERGROUND 3x90 kL FUEL TANKS
SPEL Puraceptor UG Tank Dirty Water Separator
T1ULP45kL
T2ULP45kL
T3P9835kL
T4DSL55kL
T5DSL70kL
T6ADB20kL
Subject to separate signage application.
P.3 P.6
Stormwater Swale
1 2 3 4 5 6 7 8 9 10
Print Date
PRELIMINARY
The intellectual manifestation of this drawing and its Revit file generated origin is subject to Global copyright. Its use is subject to the approval of its owners and authors under license for implementation of a construction process specfic to a single site and location. Reproduction and/or use of it, in full or part, for any other purpose without the written approval of its owners and authors is illegal and and subject to prosecution. www.lapl.com.au [email protected] 864 146
Project Number Project Name
Sheet Name
Address
Drawings produced in Autodesk Revit. Noted dimensions shall be taken in preference to scaling. Do not scale or dimension by hand. Verify all dimensions on site prior to construction or quote. Upon receipt of updated pans, discard previous versions. at A3Scale: 1 : 500 at A1 23/06/2021 12:27:04 PM
Heywood Mobil Pegasus
Mobil Pegasus
3013 Henty Highway, Heywood 3304
A1.01 Site Plan
326
0
SCALE 1:
25
500
20151055
m
1 : 500Site
1Revision Description Date
A Extra Truck Bay Added 10/02/21B Bowser added to Truck Bay, Pylon signs added 26/02/21C Traffic update, Fuel tanks updated 22/06/21
Version: 1, Version Date: 02/07/2021Document Set ID: 2864932
Print Date
PRELIMINARY
The intellectual manifestation of this drawing and its Revit file generated origin is subject to Global copyright. Its use is subject to the approval of its owners and authors under license for implementation of a construction process specfic to a single site and location. Reproduction and/or use of it, in full or part, for any other purpose without the written approval of its owners and authors is illegal and and subject to prosecution. www.lapl.com.au [email protected] 864 146
Project Number Project Name
Sheet Name
Address
Drawings produced in Autodesk Revit. Noted dimensions shall be taken in preference to scaling. Do not scale or dimension by hand. Verify all dimensions on site prior to construction or quote. Upon receipt of updated pans, discard previous versions. at A3Scale: at A1 23/06/2021 12:27:06 PM
Heywood Mobil Pegasus
Mobil Pegasus
3013 Henty Highway, Heywood 3304
A1.01b Swept Paths Analysis for original Planning Permit P19158
326
0
SCALE 1:
2.5
50
21.510.50.5
m
FOR INFORMATION ONLYPrevious DA Swept Paths shown for information to confirm no change to highway access provisions.
Revision Description Date
Version: 1, Version Date: 02/07/2021Document Set ID: 2864932
2
P.G
C.A
C.B
C.2C.1
S.B
CONVENIENCE STORE/ROADHOUSE
Servery windowS.A
Doors 920 to satisfy AS1428.1
Doors 920 to satisfy AS1428.1
Doors 920 to satisfy AS1428.1
9L WaterFire Ext.
9L WaterFire Ext.
9L WaterFire Ext.
2A20BEDry ChemFire Ext.
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
- -
-
-
- -
-
-
-
-
-
- -
-
--
-
--
-
-
-
-
--
-
--
-
-
--
-
-
-
- -
-
-
-
-
-
-
-
- -
-
- -
FreezerUnder
FridgeUnder
MW SP
Bain-marie
POS
Auto
Slid
ing
Entry
OfficeFridge Dry StoreFreezer
Kitchen
TruckersLounge
MaleShower
Male
FemaleShower
Disabled
Retail Area
Entry
Basin
CombiOven
BroomCpbd
MSB
Food StationU/bnch Fridge
CleanersSink
Coffee
POS POS
Self-serve Coffee
Awni
ng lin
e ov
er
DP from awning to st. water
connection
8 Door Coolroom2 Door Freezer
Female
Staff Toilet
Servery window
1000
1055
1515
1200
1100
1250
1250
125012501180
1950
2700
P.3 P.6
Print Date
PRELIMINARY
The intellectual manifestation of this drawing and its Revit file generated origin is subject to Global copyright. Its use is subject to the approval of its owners and authors under license for implementation of a construction process specfic to a single site and location. Reproduction and/or use of it, in full or part, for any other purpose without the written approval of its owners and authors is illegal and and subject to prosecution. www.lapl.com.au [email protected] 864 146
Project Number Project Name
Sheet Name
Address
Drawings produced in Autodesk Revit. Noted dimensions shall be taken in preference to scaling. Do not scale or dimension by hand. Verify all dimensions on site prior to construction or quote. Upon receipt of updated pans, discard previous versions. at A3Scale: 1 : 50 at A1 23/06/2021 12:27:13 PM
Heywood Mobil Pegasus
Mobil Pegasus
3013 Henty Highway, Heywood 3304
A1.02 Floor Plan
326
0
SCALE 1:
2.5
50
21.510.50.5
m
1 : 50Ground Floor
1
Revision Description DateA Office window added, Truckie lounge window shifted 26/02/21
Version: 1, Version Date: 02/07/2021Document Set ID: 2864932
P.4
P.G
P.5
C.A
C.B
C.2C.1
S.B
P.F
S.A
Exhaust Hood
Exhaust Hood
Refridgerator and freezer room lighting by manufacturer
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
- -
-
-
- -
-
-
-
-
-
- -
-
--
-
--
-
-
-
-
--
-
--
-
-
--
-
-
-
- -
-
-
-
-
-
-
-
- -
-
- -
P.3 P.6
Print Date
PRELIMINARY
The intellectual manifestation of this drawing and its Revit file generated origin is subject to Global copyright. Its use is subject to the approval of its owners and authors under license for implementation of a construction process specfic to a single site and location. Reproduction and/or use of it, in full or part, for any other purpose without the written approval of its owners and authors is illegal and and subject to prosecution. www.lapl.com.au [email protected] 864 146
Project Number Project Name
Sheet Name
Address
Drawings produced in Autodesk Revit. Noted dimensions shall be taken in preference to scaling. Do not scale or dimension by hand. Verify all dimensions on site prior to construction or quote. Upon receipt of updated pans, discard previous versions. at A3Scale: 1 : 50 at A1 23/06/2021 12:27:14 PM
Heywood Mobil Pegasus
Mobil Pegasus
3013 Henty Highway, Heywood 3304
A1.03 Reflected Ceiling Plan RCP
326
0
SCALE 1:
2.5
50
21.510.50.5
m
NOTES• REFER TO ELECTRICAL, HYDRAULIC AND
MECHANICAL SERVICES DRAWINGS FOR DETAILS.
• TYPICAL FOR COOLROOM AND REFRIGERATOR: INSTALL BEACON LIGHTING AND BELL TO OUTSIDE OF COOLROOM AND FREEZER WHICH SHALL TURN ON WHEN LIGHTS WITHIN ROOMARE ACTIVATED. CO-ORDINATE EXACT REUQIREMENTS WITH COOLROOM MANUFACTURER PRIOR TO INSTALLATION.
Revision Description Date
1 : 50Ground Floor RCP
1
Version: 1, Version Date: 02/07/2021Document Set ID: 2864932
P.1 P.2 P.4
P.A
P.C
P.D
P.G
P.5 P.7
T.1T.3T.4T.5
T.A
T.B
T.C
T.D
P.B
P.F
P.E
OF
DP
OF
OF
DP
DP
DP
DP
OF
T.2
P.3 P.6
OF OFDP OF DP
P.G
C.A
C.B
C.2C.1
S.B
P.F
S.A
2°
P.3 P.6
Print Date
PRELIMINARY
The intellectual manifestation of this drawing and its Revit file generated origin is subject to Global copyright. Its use is subject to the approval of its owners and authors under license for implementation of a construction process specfic to a single site and location. Reproduction and/or use of it, in full or part, for any other purpose without the written approval of its owners and authors is illegal and and subject to prosecution. www.lapl.com.au [email protected] 864 146
Project Number Project Name
Sheet Name
Address
Drawings produced in Autodesk Revit. Noted dimensions shall be taken in preference to scaling. Do not scale or dimension by hand. Verify all dimensions on site prior to construction or quote. Upon receipt of updated pans, discard previous versions. at A3Scale: 1 : 100 at A1 23/06/2021 12:27:16 PM
Heywood Mobil Pegasus
Mobil Pegasus
3013 Henty Highway, Heywood 3304
A1.04 Roof Plan
326
0
SCALE 1:
5
100
43211
mRevision Description Date
1 : 100Roof Plan Canopies
1
1 : 100Roof Plan Convenience
2
Version: 1, Version Date: 02/07/2021Document Set ID: 2864932
Ground Floor0
Ceiling3000
Bowsers-150
TO Fascia4000
BO Canopy5050
TO Canopy6050
P.1 P.2 P.4 P.5 P.7 T.1T.3T.4T.5C.2C.1
BO Truck Canopy5350
TO Truck Canopy6350
T.2P.3 P.6
Ground Floor0
Ceiling3000
Bowsers-150
TO Fascia4000
BO Canopy5050
TO Canopy6050
P.1P.2P.4P.5P.7T.1 T.3 T.4 T.5 C.2 C.1
BO Truck Canopy5350
TO Truck Canopy6350
T.2 P.3P.6
Print Date
PRELIMINARY
The intellectual manifestation of this drawing and its Revit file generated origin is subject to Global copyright. Its use is subject to the approval of its owners and authors under license for implementation of a construction process specfic to a single site and location. Reproduction and/or use of it, in full or part, for any other purpose without the written approval of its owners and authors is illegal and and subject to prosecution. www.lapl.com.au [email protected] 864 146
Project Number Project Name
Sheet Name
Address
Drawings produced in Autodesk Revit. Noted dimensions shall be taken in preference to scaling. Do not scale or dimension by hand. Verify all dimensions on site prior to construction or quote. Upon receipt of updated pans, discard previous versions. at A3Scale: 1 : 100 at A1 23/06/2021 12:27:20 PM
Heywood Mobil Pegasus
Mobil Pegasus
3013 Henty Highway, Heywood 3304
A2.01 Elevations 1 - E W
326
0
SCALE 1:
5
100
43211
mRevision Description DateA Bowser added to Truck Canopy. Truckie lounge and toilet windows
shifted26/02/21
B Signage Branding Updated 13/05/21
1 : 100East
1
1 : 100West
2
Version: 1, Version Date: 02/07/2021Document Set ID: 2864932
Ground Floor0
Ceiling3000
Bowsers-150
TO Fascia4000
BO Canopy5050
TO Canopy6050
P.A P.C P.D P.GT.A T.B T.C T.DP.B C.A C.BS.BP.FP.E
BO Truck Canopy5350
TO Truck Canopy6350
S.A
Ground Floor0
Ceiling3000
Bowsers-150
TO Fascia4000
BO Canopy5050
TO Canopy6050
P.AP.CP.DP.G T.AT.BT.CT.D P.BC.AC.B S.B P.F P.E
BO Truck Canopy5350
TO Truck Canopy6350
S.A
Print Date
PRELIMINARY
The intellectual manifestation of this drawing and its Revit file generated origin is subject to Global copyright. Its use is subject to the approval of its owners and authors under license for implementation of a construction process specfic to a single site and location. Reproduction and/or use of it, in full or part, for any other purpose without the written approval of its owners and authors is illegal and and subject to prosecution. www.lapl.com.au [email protected] 864 146
Project Number Project Name
Sheet Name
Address
Drawings produced in Autodesk Revit. Noted dimensions shall be taken in preference to scaling. Do not scale or dimension by hand. Verify all dimensions on site prior to construction or quote. Upon receipt of updated pans, discard previous versions. at A3Scale: 1 : 100 at A1 23/06/2021 12:27:24 PM
Heywood Mobil Pegasus
Mobil Pegasus
3013 Henty Highway, Heywood 3304
A2.02 Elevations 2 - N S
326
0
SCALE 1:
5
100
43211
mRevision Description DateA Office Window added 26/02/21B Signage Branding Updated 13/05/21
1 : 100North
1
1 : 100South
2
Version: 1, Version Date: 02/07/2021Document Set ID: 2864932
2200
2995
925
2110
1800
300
765 700
1800
300
745
2125
2110
925
1900
110
740 925
2110
925
2110
1200
1800
1800
1800
600
600
Ground Floor0
Ceiling3000
P.3 P.6
Print Date
PRELIMINARY
The intellectual manifestation of this drawing and its Revit file generated origin is subject to Global copyright. Its use is subject to the approval of its owners and authors under license for implementation of a construction process specfic to a single site and location. Reproduction and/or use of it, in full or part, for any other purpose without the written approval of its owners and authors is illegal and and subject to prosecution. www.lapl.com.au [email protected] 864 146
Project Number Project Name
Sheet Name
Address
Drawings produced in Autodesk Revit. Noted dimensions shall be taken in preference to scaling. Do not scale or dimension by hand. Verify all dimensions on site prior to construction or quote. Upon receipt of updated pans, discard previous versions. at A3Scale: As indicated at A1 23/06/2021 12:27:26 PM
Heywood Mobil Pegasus
Mobil Pegasus
3013 Henty Highway, Heywood 3304
A6.02 Door Window Schedule
326
1 : 20Door Legend
Door Schedule
Type Mark Height Width Thickness FinishFrameMaterial Comments
D7 2100 700 100D9 2100 920 40D10 2000 750 30D12 2100 920 40Grand total: 30
Door Schedule
Type Mark Height Width Thickness FinishFrameMaterial Comments
72 2100 720D1 2525 1750 40D2 2100 920 40D4 1800 765 50D5 1800 700 50D6 2550 2200
1 : 20Window Legend
1 : 50Windows East
1
Revision Description Date
Version: 1, Version Date: 02/07/2021Document Set ID: 2864932