25
SEATTLE SPOKANE WASHINGTON STATE REDMOND SITE DATA TABLE (ref. RZC 21.08.060B) AVERAGE LOT SIZE 7000 SF 103,849 SF DENSITY 80% OF NET ACRES N/A - EXISTING LOT LOT WIDTH CIRCLE 40 FEET 40' - 0" FRONT SETBACK 15 FEET 15' - 0" GARAGE SETBACK 18 FEET N/A - NO GARAGE SIDE/INTERIOR SETBACK 5 FEET/10 FEET 5' - 0" REAR SETBACK 10 FEET 10' - 0" BUILDING SEPARATION 10 FEET 16' - 10 1/4" OPEN SPACE 20% OF TOTAL LOT AREA (20,770 SF) 93% (96,614 SF) MAXIMUM REQUIRED PROVIDED LOT COVERAGE FOR STRUCTURES 35% OF TOTAL LOT AREA 7% (7235 SF) IMPERVIOUS SURFACE 60% OF TOTAL LOT AREA 26.9% BUILDING HEIGHT 35 FEET 15 FEET (NEW ADDITION) 21 FEET (EXISTING) LOT FRONTAGE 20 FEET 164' - 11" MINIMUM REQUIRED PROVIDED YES YES YES N/A - NO GARAGE YES YES YES YES MEETS REQ'S YES YES YES YES MEETS REQ'S N/A - EXISTING LOT BUILDING DATA TABLE N/A N/A ADDITION AND REMODEL E OCCUPANCY (EDUCATION) E OCCUPANCY R OCCUPANCY (RESIDENTIAL) N/A - NO CHANGE N/A - NO CHANGE N/A - NO CHANGE 610 SF 3300 SF 360 SF 3000 SF BUILDING A BUILDING B BUILDING C SCOPE OF WORK EXISTING OCCUPANCY NEW OCCUPANCY ADDITION SF EXISTING SF N/A - NO CHANGE E OCCUPANCY CAMPUS 610 SF 6600 SF TOTAL SF 3300 SF - NO CHANGE 360 SF - NO CHANGE 3610 SF 7270 SF PLAN SET 00 GENERAL G1.01 COVER SHEET 02 CIVIL C1.00 DEMOLITION AND TESC PLAN C1.10 TESC DETAILS C2.00 GRADINGPLAN C2.10 GRADING AND PAVING DETAILS C3.00 DRAINAGE AND UTILITY PLAN C3.10 UTILITY DETAILS C4.00 PAVING AND HORIZONTAL CONTROL POINTS C5.00 FIRE PLAN 04 LANDSCAPE L1.01 LANDSCAPE DEMO PLAN L1.02 LANDSCAPE AND IRRIGATION PLAN TP1.01 TREE PRESERVATION PLAN 06 ARCHITECTURAL A1.02 SITE PLAN SHEET INDEX N Scale: NTS VICINITY MAP N Scale: NTS LOCATION MAP 2025 FIRST AVE | SUITE 300 SEATTLE WA 98121 P:206.441.4522 2025 FIRST AVE | SUITE 300 SEATTLE WA 98121 P:206.441.4522 2025 FIRST AVE | SUITE 300 SEATTLE WA 98121 P:206.441.4522 2025 FIRST AVE | SUITE 300 SEATTLE WA 98121 P:206.441.4522 CHECKED DRAWN DATE REVISIONS NAC NO © 2019 NAC inc nacarchitecture.com 10/26/2020 9:18:55 PM D:\_Revit\Cascadia-AdditionAndRemodel_AVacek.rvt 10-19-2020 AV G1.01 121-18031 CASCADIA SCHOOL 4239 162ND AVE NE, REDMOND , WA, 98052 KF PERMIT SET EAST BUILDING REMODEL AND ADDITION COVER SHEET ARCHITECTURAL PLAN SET 00 GENERAL G1.01 COVER SHEET 06 ARCHITECTURAL A3.01 DEMO AND FLOOR PLAN A4.01 EXTERIOR ELEVATIONS 14 ELECTRICAL E1.02 ELECTRICAL SITE / PHOTOMETRICS PLAN PARCEL NUMBER: 142505 - 9033 ZONING: R - 4 CONSTRUCTION TYPE: 5B GROSS ALLOWABLE AREA: 38,000 SF PROPOSED NEW GROSS AREA: 610 SF BASIS OF BEARINGS: WASHINGTON STATE PLANE NORTH, NAD 1983 (91 - HARN) PER CITY OF REDMOND (COR) CITY OF REDMOND CONTROL POINT DESIGNATION GPS90 - 3G2 , BEING A 3" BRASS DISC WITH PUNCH DOWN 1.67', AT INTERSECTION OF NORTHEAST 40TH STREET & 156TH AVENUE NORTHEAST WAS HELD FOR POSITION AND A LINE BETWEEN SAID POINT GPS90 - 3G2 AND CITY OF REDMOND POINT DESIGNATION NO. GLO - 4GSW, BEING A 3" BRASS DISC WITH PUNCH DOWN 0.72', 15'± EAST OF INTERSECTION OF NORTHEAST 40TH STREET & 164TH AVENUE NORTHEAST WAS HELD FOR ROTATION. BEARING BETWEEN THESE MONUMENTS WAS TAKEN AS SOUTH 89°10'27" EAST. VERTICAL DATUM IS NAVD88 PER CITY OF REDMOND PUBLISHED BENCHMARK VERTICAL DATUM FOR THIS SURVEY IS ESTABLISHED PER THE PUBLISHED ELEVATION OF CITY OF REDMOND POINT DESIGNATION COR 9117, BEING A 3" BRASS DISC IN MONUMENT CASE 4.4' SOUTH OF THE SOUTH EDGE OF CONCRETE SIDEWALK ON NORTHEAST 40TH STREET, 30'± WEST OF THE CENTERLINE OF 162ND AVENUE NORTHEAST STAMPED "CITY OF REDMOND BM 66". ELEVATION WAS HELD AT 309.52' CHECK BETWEEN PROJECT BENCHMARK AND CITY OF REDMOND POINT DESIGNATION COR9118, BEING A 2" BRASS DISC AT THE NORTHWEST CORNER OF A CONCRETE PAD FOR TRAFFIC CONTROL RISERS AT THE SOUTHEAST QUADRANT OF BELLEVUE - REDNOND ROAD AND NORTHEAST 40TH STREET, RESULTED IN A VERTICAL CLOSURE OF 0.155' OF PUBLISHED. NOTE: STORMWATER CAPITAL FACILITIES CHARGE FEE IS APPLICABLE AT PERMIT ISSUANCE. NOTE: A SPRINKLER SYSTEM WITH QUICK - RESPONSE HEADS WILL BE INSTALLED IN ACCORDANCE WITH IBC CHAPTER 9 AND NFPA - 13. SPRINKLER DRAWINGS TO BE SUBMITTED BY LICENSED INSTALLER AS DEFERRED SUBMITTAL AFTER PROJECT BIDS. OWNER CASCADIA SCHOOL 4239 162ND AVE NE REDMOND, WA 98052 425.881.2825 PHILIP KEETON ARCHITECT NAC|ARCHITECTURE 2025 1ST AVE SUITE 300 SEATTLE, WA 98121 206.441.4522 KEVIN FLANAGAN CIVIL ENGINEER JACOBSON ENGINEERING 255 S KING ST SUITE 800 SEATTLE, WA 98104 206.399.6233 ALAN JACOBSON ARBORIST DAVEY RESOURCE GROUP INC. 18809 10TH AVE NE SHORELINE, WA 98155 206.714.3147 IAN SCOTT STRUCTURAL ENGINEER SWENSON SAY FAGET 2124 3RD AVE SUITE 100 SEATTLE, WA 98121 206.443.6212 GREGORY JUTTNER ELECTRICAL ENGINEER NAC ENGINEERING 2025 1ST AVE SUITE 300 SEATTLE, WA 98121 206.441.4522 MARK MCMICHAEL

SHEET INDEX - Redmond

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

SEATTLE

SPOKANE

WASHINGTON STATE

REDMOND

SITE DATA TABLE (ref. RZC 21.08.060B)

AVERAGE LOT SIZE 7000 SF 103,849 SF

DENSITY 80% OF NET ACRES N/A - EXISTING LOT

LOT WIDTH CIRCLE 40 FEET 40'-0"

FRONT SETBACK 15 FEET 15'-0"

GARAGE SETBACK 18 FEET N/A - NO GARAGE

SIDE/INTERIOR SETBACK 5 FEET/10 FEET 5'-0"

REAR SETBACK 10 FEET 10'-0"

BUILDING SEPARATION 10 FEET 16'-10 1/4"

OPEN SPACE 20% OF TOTAL LOT AREA (20,770 SF)

93% (96,614 SF)

MAXIMUM REQUIRED PROVIDED

LOT COVERAGE FOR STRUCTURES

35% OF TOTAL LOT AREA 7% (7235 SF)

IMPERVIOUS SURFACE 60% OF TOTAL LOT AREA 26.9%

BUILDING HEIGHT 35 FEET 15 FEET (NEW ADDITION)21 FEET (EXISTING)

LOT FRONTAGE 20 FEET 164'-11"

MINIMUM REQUIRED PROVIDED

YES

YES

YES

N/A - NO GARAGE

YES

YES

YES

YES

MEETS REQ'S

YES

YES

YES

YES

MEETS REQ'S

N/A - EXISTING LOT

BUILDING DATA TABLE

N/A N/A ADDITION AND REMODEL

E OCCUPANCY(EDUCATION)

E OCCUPANCY R OCCUPANCY(RESIDENTIAL)

N/A - NO CHANGE

N/A - NO CHANGE N/A - NO CHANGE 610 SF

3300 SF 360 SF 3000 SF

BUILDING A BUILDING B BUILDING C

SCOPE OF WORK

EXISTING OCCUPANCY

NEW OCCUPANCY

ADDITION SF

EXISTING SF

N/A - NO CHANGE E OCCUPANCY

CAMPUS

610 SF

6600 SF

TOTAL SF 3300 SF - NO CHANGE 360 SF - NO CHANGE 3610 SF 7270 SF

PLAN SET

00 GENERAL

G1.01 COVER SHEET

02 CIVIL

C1.00 DEMOLITION AND TESC PLAN

C1.10 TESC DETAILS

C2.00 GRADINGPLAN

C2.10 GRADING AND PAVING DETAILS

C3.00 DRAINAGE AND UTILITY PLAN

C3.10 UTILITY DETAILS

C4.00 PAVING AND HORIZONTAL CONTROL POINTS

C5.00 FIRE PLAN

04 LANDSCAPE

L1.01 LANDSCAPE DEMO PLAN

L1.02 LANDSCAPE AND IRRIGATION PLAN

TP1.01 TREE PRESERVATION PLAN

06 ARCHITECTURAL

A1.02 SITE PLAN

SHEET INDEX

N

Scale: NTS

VICINITY MAP

N

Scale: NTS

LOCATION MAP

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

CHECKED

DRAWN

DATE

REVISIONS

NAC NO

© 2

01

9 N

AC

in

c

nacarchitecture.com

10/26/2020 9:18:55 PM D:\_Revit\Cascadia-AdditionAndRemodel_AVacek.rvt

10-19-2020

AV

G1.01

121-18031

CA

SC

AD

IA S

CH

OO

L

42

39

16

2N

D A

VE

NE

, R

ED

MO

ND

, W

A, 9

80

52

KF

PE

RM

IT S

ET

EA

ST

BU

ILD

ING

RE

MO

DE

L A

ND

AD

DIT

ION

COVER SHEET

ARCHITECTURAL PLAN SET

00 GENERAL

G1.01 COVER SHEET

06 ARCHITECTURAL

A3.01 DEMO AND FLOOR PLAN

A4.01 EXTERIOR ELEVATIONS

14 ELECTRICAL

E1.02 ELECTRICAL SITE / PHOTOMETRICS PLAN

PARCEL NUMBER:142505-9033

ZONING:R-4

CONSTRUCTION TYPE: 5B

GROSS ALLOWABLE AREA: 38,000 SF

PROPOSED NEW GROSS AREA: 610 SF

BASIS OF BEARINGS: WASHINGTON STATE PLANE NORTH, NAD 1983 (91-HARN) PER CITY OF REDMOND (COR)CITY OF REDMOND CONTROL POINT DESIGNATION GPS90-3G2 , BEING A 3" BRASS DISC WITH PUNCH DOWN 1.67', AT INTERSECTION OF NORTHEAST 40TH STREET & 156TH AVENUE NORTHEAST WAS HELD FOR POSITION AND A LINE BETWEEN SAID POINT GPS90-3G2 AND CITY OF REDMOND POINT DESIGNATION NO. GLO-4GSW, BEING A 3" BRASS DISC WITH PUNCHDOWN 0.72', 15'± EAST OF INTERSECTION OF NORTHEAST 40TH STREET & 164TH AVENUE NORTHEAST WAS HELD FOR ROTATION. BEARING BETWEEN THESE MONUMENTS WAS TAKEN AS SOUTH 89°10'27" EAST.

VERTICAL DATUM IS NAVD88 PER CITY OF REDMONDPUBLISHED BENCHMARKVERTICAL DATUM FOR THIS SURVEY IS ESTABLISHED PER THE PUBLISHED ELEVATION OF CITY OF REDMOND POINT DESIGNATION COR 9117, BEING A 3" BRASS DISC IN MONUMENT CASE 4.4' SOUTH OF THE SOUTH EDGE OF CONCRETE SIDEWALK ON NORTHEAST 40TH STREET, 30'± WEST OF THE CENTERLINE OF 162ND AVENUE NORTHEAST STAMPED "CITY OF REDMOND BM 66". ELEVATION WAS HELD AT 309.52'

CHECK BETWEEN PROJECT BENCHMARK AND CITY OF REDMOND POINT DESIGNATION COR9118, BEING A 2" BRASS DISC AT THE NORTHWEST CORNER OF A CONCRETE PAD FOR TRAFFIC CONTROL RISERS AT THE SOUTHEAST QUADRANT OF BELLEVUE-REDNOND ROAD AND NORTHEAST 40TH STREET, RESULTED IN A VERTICAL CLOSURE OF 0.155' OF PUBLISHED.

NOTE: STORMWATER CAPITAL FACILITIES CHARGE FEE IS APPLICABLE AT PERMIT ISSUANCE.

NOTE: A SPRINKLER SYSTEM WITH QUICK-RESPONSE HEADS WILL BE INSTALLED IN ACCORDANCE WITH IBC CHAPTER 9 AND NFPA-13. SPRINKLER DRAWINGS TO BE SUBMITTED BY LICENSED INSTALLER AS DEFERRED SUBMITTAL AFTER PROJECT BIDS.

OWNER

CASCADIA SCHOOL4239 162ND AVE NEREDMOND, WA 98052425.881.2825PHILIP KEETON

ARCHITECT

NAC|ARCHITECTURE2025 1ST AVE SUITE 300SEATTLE, WA 98121206.441.4522KEVIN FLANAGAN

CIVIL ENGINEER

JACOBSON ENGINEERING255 S KING ST SUITE 800SEATTLE, WA 98104206.399.6233ALAN JACOBSON

ARBORIST

DAVEY RESOURCE GROUP INC.18809 10TH AVE NESHORELINE, WA 98155206.714.3147IAN SCOTT

STRUCTURAL ENGINEER

SWENSON SAY FAGET2124 3RD AVE SUITE 100SEATTLE, WA 98121206.443.6212GREGORY JUTTNER

ELECTRICAL ENGINEER

NAC ENGINEERING2025 1ST AVE SUITE 300SEATTLE, WA 98121206.441.4522MARK MCMICHAEL

DW

WH

T

OV

EN

DW

WH

WH

OVEN

CLASSROOM

102

WORK ROOM

103

STORAGE

103A

LOBBY

101

CLASSROOM

107

TOILET

106

TOILET

105

TOILET

104

CLASSROOM

108

20'-3

241/2

56"

21'-7 1/8" 8'-0"

2'-6

"1

0'-4 1

/8"

29'-7 1/8"

FIRE RISER

109

A4.01

2

A4.011

A4.013

A7.021D

1A

1B

1C

A7.02

4C

4B

4A

4D

A7.02

3A

3E 3C

3D

A7.02

3B

A7.02 2A2C

2B

1E

A7.031

25

3

A7.03

4

A7.02 2D2E

4'-9

1/2

"

19'-3

"

2

A4.04

1

A4.04

3

A4.04

4

A4.04

A7.0114

2E

2F

2G

A7.01

2A

2D

2C

A7.01 1F

1E

18

1G

A7.01

1B

1A

1C

1D

A7.01

3C

3D

3B

3A

2B

CLASSROOM

110

TOILET

110A

LOUVERED DOORS

A7.01

A

A7.01

B

4'-2 1/4"

9'-2 3/8"

5'-7 1/2"

7'-6"

6'-9

"

19'-8 3/16"

24'-0

1/2

"

1'-1

0 1

1/1

6"

21S

B

21 B

S 20A

R

20A

R

1A

20 AR

2A

2A

A

2 AA

1A

20RA

20R

A

21BS

2A

A

21B

S

1AA

20R

A

1A

A1

A

A

1AA

1A

A

1AA

1A

A

2AA

2A

A1

A

A

1AA

1AA

1A

A

1A

A

110

110A

101

108

109

107

102A

107A

104

105

106

102

ELEC

102A

STOR

107A

A4.01

7

A4.01 6

A4.01

4

A4.01 5

5'-0 3/8"3'-3"

12

2

7

5

2

6

8

4

3

1. SEE MAIN FLOOR PLAN FOR DIMENSIONS AND WALL TYPE REFERENCES.

2. SEE DOOR AND RELITE SCHEDULES, SHEET A3.04 FOR DOOR HARDWARE AND OTHER FIRE RATING REQUIREMENTS FOR DOORS AND RELITES.

3. SEE ELECTRICAL FOR EXIT SIGNS AND EMERGENCY EGRESS LIGHT FIXTURES.

4. STORAGE AND USE OF CLASS I, II AND IIIA LIQUIDS ARE PROHIBITED EXCEPT IN APPROVED QUANTITIES AS NECESSARY IN CLASSROOMS FOR OPERATION AND MAINTENANCE. THE QUANTITIES OF OTHER HAZARDOUS MATERIALS SHALL BE AS APPROVED BY THE FIRE MARSHALL.

5. BUILDING IS COMBUSTIBLE FULLY SPRINKLERED CONSTRUCTION. AREAS OF EVACUATION ASSISTANCE ARE NOT REQUIRED. QUICK RESPONSE HEADS ARE USED WHERE ALLOWED BY IBC CHAPTER 9 AND A WRITTEN EVACUATION PLAN WILL BE SUBMITTED FOR APPROVAL PRIOR TO OCCUPANCY.

6. ARCHITECT SHALL REVIEW ALL DEFERRED SUBMITTALS AND VERIFY COMPLIANCE WITH THE DESIGN CONCEPT AND CODE REQUIREMENTS RELATING TO:A. AUTOMATIC SPRINKLER SYSTEM DESIGN DRAWINGS.B. MANUAL AND AUTOMATIC FIRE ALARM DRAWINGS.C. INSTALLATION DETAILS OF ACOUSTICAL CEILING SUSPENSION SYSTEM.D. INSTALLATION DETAILS OF MEMBRANE AND THROUGH-PENETRATION FIRE STOPS, AND FIRE-RESISTIVE

JOINT SYSTEMS.E. DESIGN DETAILS AND STRUCTURAL CALCULATIONS FOR THE SEISMIC ANCHORAGE AND BRACING OF

EACH PIECE OF FLOOR MOUNTED AND ROOF MOUNTED MECHANICAL AND OTHER EQUIPMENT WEIGHING 400 POUNDS OR MORE.

F. WRITTEN FIRE AND LIFE SAFETY EMERGENCY PLAN, WHICH SPECIFICALLY ADDRESSES THE EVACUATION OF PERSONS WITH DISABILITIES.

1. APPROVED AUDIBLE SPRINKLER FLOW ALARMS SHALL BE INSTALLED WITHIN THE BUILDING AND ON THE EXTERIOR IN APPROVED LOCATIONS; ACTUATION SHALL CONFORM TO IBC CHAPTER 9. ELECTRICAL VALVE MONITORING FOR SPRINKLER SYSTEM AND WATER FLOW SWITCHES SHALL BE INSTALLED AND CONNECTED TO AN APPROVED CENTRAL, REMOTE, OR PROPRIETARY MONITORING STATION.

2. AN APPROVED MANUAL AND AUTOMATIC FIRE ALARM SYSTEM SHALL BE INSTALLED AS SPECIFIED IN THE FIRE CODE; VISIBLE ALARMS COMPLYING WITH WSBC SECTION 1106.15.2 SHALL BE INSTALLED IN ALL COMMON-USE AREAS, ASSEMBLY AREAS, TOILET ROOMS, HALLWAYS, LOBBIES AND CORRIDORS.

3. INTERIOR WALL AND CEILING FINISHES SHALL CONFORM TO IBC SECTION 803 AND TABLE 803.11 FOR FLAME SPREAD REQUIREMENTS.

FLOOR PLAN GENERAL NOTES

1. THE DEMOLITION PLANS INCLUDE THE SCOPE OF DEMOLITION WORK REQUIRED PRIOR TO STARTING THE MODERNIZATION WORK, BUT ARE NOT INTENDED TO INCLUDE ALL OF THE DETAIL REQUIREMENTS. ALL DEMOLITION WORK NOT SHOWN ON DRAWINGS OR SPECIFIED WHICH IS REQUIRED FOR COMPLETION OF WORK INCLUDED IN THE CONTRACT DOCUMENTS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.

2. COORDINATE ALL DEMOLITION WORK WITH ALL TRADES AND REVIEW DRAWINGS FOR EXACT LOCATIONS OF ALL OPENINGS, ETC., PRIOR TO STARTING WORK.

3. ALL EXISTING WALLS, STRUCTURE, DOORS AND OTHER ITEMS TO REMAIN ARE SHOWN AS SOLID LINES OR INDICATED AS SUCH BY NOTE. ALL STRUCTURAL MEMBERS, SLABS AND ROOF STRUCTURE/DECKS ARE TO REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE. ALL STRUCTURE, WALLS, DOORS, WINDOWS, CABINETRY, EQUIPMENT, FIXTURES, ETC., TO BE REMOVED ARE SHOWN DASHED OR NOTED AS SUCH. REMOVE ALL ACCESSORIES, EQUIPMENT, FIXTURES, FINISHES OTHER THAN PAINT, ETC. ... WHETHER SPECIFICALLY SHOWN OR NOT, UNLESS NOTED OTHERWISE.

4. SEE ELECTRICAL DRAWINGS FOR DESCRIPTION OF WORK UNDER THOSE SUBCONTRACTORS, INCLUDING UTILITIES AND FIXTURES (I.E., SINKS, TOILET FIXTURES, EXTERIOR LIGHT FIXTURES) SHOWN TO BE REMOVED ON THIS PLAN.

5. SEE SITE PLAN, ROOF PLAN, BUILDING ELEVATIONS, DETAILS AND STRUCTURAL DRAWINGS FOR ADDITIONAL DEMOLITION INFORMATION RELATING TO THOSE AREAS OF WORK AND NOT SPECIFICALLY NOTED HERE.

6. EXTERIOR WALLS TO BE REMOVED ARE GENERALLY WOOD FRAMED.

7. INTERIOR WALLS TO BE REMOVED ARE GENERALLY WOOD FRAMED UNLESS NOTED OTHERWISE.

8. ALL STRUCTURAL MEMBERS INCLUDING BEARING WALLS AFFECTED BY THIS DEMOLITION ARE TO BE VERIFIED AND ADEQUATELY SHORED BEFORE REMOVAL.

9. ALL EXISTING FINISH FLOORING IS TO BE REMOVED TO EXISTING SUBFLOOR, UNLESS NOTED OTHERWISE. ALL EXISTING FINISH FLOORING IS ASSUMED TO BE WOOD FLOORING UNLESS NOTED OTHERWISE. INFILL, PATCH AND REPAIR AS NECESSARY TO PREP FOR NEW FLOORING INCLUDING AT REMOVED WALLS.

10. DOORS SHOWN TO BE REMOVED INCLUDE DOORS, FRAMES, SIDELITES, TRANSOMS, CENTER POSTS, PIPE RAILS, HARDWARE, STOPS AND ADJACENT FURRING TO FULLY REVEAL ROUGH OPENING.

11. ALL MASONRY REMOVAL IS TO BE REMOVED BY SAWCUTTING. PATCH AND REPAIR EXPOSED WALLS DAMAGED BY REMOVAL OF WORK AND LEAVE IN NEAT, CLEAN, FINISHED CONDITION. PROVIDE NEW LINTEL TO SUPPORT CMU. SEE STRUCTURAL DRAWINGS FOR DETAILS.

12. NEW WALL OPENINGS IN EXISTING WALLS NOT DIMENSIONED ON THIS PLAN ARE SHOWN ON THE FLOOR PLANS. NEW OPENINGS IN EXISTING CONCRETE WALLS ARE TO BE SAWCUT.

13. PATCH AND REPAIR ALL DAMAGED AREAS AFFECTED BY THIS WORK.

14. MISC NEW WORK TRIGGERED BY DEMOLITION IS SHOWN HERE ON DEMOLITION PLANS.

15. REMOVE EXISTING FLOOR SLABS AS REQUIRED FOR NEW PAD & CONTINUOUS FOOTINGS. COORDINATE WITH STRUCTURAL DRAWINGS. PROVIDE NEW 4" CONC SLAB INFILL OVER VAPOR BARRIER AND SPEC'D SUBSTRATE GRAVEL AFTER COL/FOOTINGS ARE INSTALLED.

16. ALL VOIDS IN GRADE OR BELOW SLABS RESULTING FROM THIS WORK ARE TO BE FILLED WITH COMPACTED STRUCTURAL FILL OR CONTROLLED DENSITY FILL TO REQUIRED NEW ELEVATION PRIOR TO CONTINUING CONSTRUCTION.

17. REMOVAL OF EXISTING EXTERIOR WALLS INCLUDES REMOVAL OF ASSOCIATED FOUNDATION WALL & FOOTING, UNLESS NOTED OTHERWISE. SEE CODED NOTES AND STRUCTURAL DRAWINGS FOR FURTHER CLARIFICATION.

GENERAL DEMOLITION NOTES

DEMOLITION PLAN LEGEND

FRAMED WALL TO BE REMOVED

EXISTING WALL TO REMAIN

EXISTING DOOR AND FRAME TO BE REMOVED

EXISTING WINDOW AND FRAME TO BE REMOVED

REMOVE DOOR, FRAME AND ALL ASSOCIATED HARDWARE TO LEAVE CLEAN OPENING FOR INFILL

REMOVE PLUMBING FIXTURES, CABINETRY AND BATHROOM ACCESSORIES

REMOVE PLUMBING FIXTURES, CABINETRY AND KITCHEN ACCESSORIES

REMOVE GARAGE DOOR AND ACCESSORIES

REMOVE WATER HEATER

REMOVE FURNACE

REMOVE STOVE, HEARTH AND ACCESSORIES

REMOVE CENTRAL VACUUM AND ACCESSORIES, CAP CONNECTIONS

DEMO PLAN CODED NOTES

1

2

3

4

5

6

7

8

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

CHECKED

DRAWN

DATE

REVISIONS

NAC NO

© 2

01

9 N

AC

in

c

nacarchitecture.com

10/26/2020 9:18:54 PM D:\_Revit\Cascadia-AdditionAndRemodel_AVacek.rvt

10-19-2020

AV

A3.01

121-18031

CA

SC

AD

IA S

CH

OO

L

42

39

16

2N

D A

VE

NE

, R

ED

MO

ND

, W

A, 9

80

52

KF

PE

RM

IT S

ET

EA

ST

BU

ILD

ING

RE

MO

DE

L A

ND

AD

DIT

ION

DEMO AND FLOOR

PLANN

Scale: 1/8" = 1'-0"1FLOOR PLAN - LEVEL 1

Scale: 1/8" = 1'-0"2DEMO FLOOR PLAN

N

CODED NOTES - FLOOR PLAN#

LEVEL 1100'-0"

RESIDENCE ROOF109'-4"

GARAGE ROOF111'-0"

GARAGE LEVEL102'-0"

3

A4.04

3/4

"9

'-4

"

STRUCTURE BEYOND REMOVED FOR CLARITY

LEVEL 1100'-0"

RESIDENCE ROOF109'-4"

GARAGE ROOF111'-0"

GARAGE LEVEL102'-0"

4

A4.04

7'-10

"1

'-6

"

EXISITNG STRUCTURE REMOVED FOR CLARITY

EXISITNG STRUCTURE REMOVED FOR CLARITY

T TTT

LEVEL 1100'-0"

RESIDENCE ROOF109'-4"

GARAGE ROOF111'-0"

GARAGE LEVEL102'-0"

1

A4.04

7'-6

"1

'-6

"

EXISITNG STRUCTURE REMOVED FOR CLARITY

T T

LEVEL 1100'-0"

RESIDENCE ROOF109'-4"

GARAGE ROOF111'-0"

GARAGE LEVEL102'-0"

2

A4.04

MA

TC

H E

XIS

TIN

G

9'-0

"

TTT

LEVEL 1100'-0"

RESIDENCE ROOF109'-4"

GARAGE ROOF111'-0"

GARAGE LEVEL102'-0"

1

A4.04

9'-0

"

EXISITNG STRUCTURE REMOVED FOR CLARITY

1. LOCATION AND SPACING OF WINDOW MULLIONS, MASONRY CONTROL JOINTS AND COURSE PATTERNS, ETC, ARE TO BE AS SHOWN ON EXTERIOR ELEVATIONS. WHERE NOT DIMENSIONED OR DETAILED, WINDOW MULLIONS AND MATERIAL JOINTS ARE TO BE EQUALLY SPACED AND/ OR CENTERED/ ALIGNED W/ ADJACENT ELEMENT (MASONRY COLUMN, EDGE OR CENTER LINE OF WINDOW OR DOOR OPENING, ETC) AS SHOWN.

2. REFER TO DETAILS FOR DIMENSION REFERENCE POINTS.

3. CONTROL JOINTS EXTEND FULL HEIGHT OF MASONRY, TYP. WHERE "CJ" IS INDICATED AT INSIDE CORNERS THE JOINT SHALL PENETRATE THE MASONRY SURFACE ON WHICH THE LABEL OCCURS. SEE DETAILS FOR ADDITIONAL CJ LOCATIONS.

4. ALL WINDOW AND LOUVER DIMENSIONS ARE FOR ROUGH OR MASONRY OPENING, UNLESS NOTED OTHERWISE. SEE PLANS FOR ADDITIONAL DIMENSION INFORMATION.

5. 100'-0" IS THE DATUM ELEVATION AND CORRESPONDS TO THE REFERENCED FLOOR SLAB ELEVATION 275.80'. SEE CIVIL FOR FURTHER INFORMATION.

6. EXTERIOR WALL FINISHES EXTEND FULL HEIGHT TO SOFFITS (NOT SHOWN WHERE EAVES OBSCURE VIEW). SEE BUILDING SECTIONS & DETAILS.

7. SEE REFLECTED CEILING PLANS (RCP) FOR CEMENT FIBER BOARD CLAD SOFFIT COLORS. CEMENT FIBER BOARD CLAD FINS & VERT FACE OF SOFFIT TO MATCH COLOR OF ASSOCIATED SOFFIT AS NOTED ON RCP.

EXTERIOR ELEVATION GENERAL NOTES

CEMENT FIBER BOARD

COMPOSITION SHINGLE ROOFING

WOOD SIDING

NOTE: THIS LEGEND DOES NOT INCLUDE ALLMATERIALS. SEE NOTES & REFERENCED DETAILSFOR ADDITIONAL INFORMATION.

CLEAR GLASS

TEMPERED GLASS WHERE REQUIRED

MATERIALS LEGEND GLAZING LEGEND

T

1. EXTERIOR FINISH NOTES APPLY TO BUILDING AND SITE.

2. EXTERIOR STEEL DOORS AND FRAMES TO BE PT 6.X.

3. ALL METAL FASCIA AND CONTINOUS CLEATS TO BE PT 6.X (FACTORY FINISH).

4. EXTERIOR LOUVERS AND ASSOCIATED EXPOSED FLASHING COLOR TO MATCH SIDING.

5. ALL EXPOSED CAST IN PLACE CONCRETE TO HAVE A CLEAR SEALER PER SPECIFICATIONS.

6. ALL METAL FINS/ SOFFITS TO BE PT 6.X (FACTORY FINISH), UNLESS NOTED OTHERWISE.

7. BIKE RACKS TO BE GALVANIZED STEEL, NO PAINT.

8. SIGN POSTS, BOLLARDS, AND STEEL GATES TO BE PT 6.X.

9. ALL GUTTERS TO BE PT 6.X (FACTORY FINISH), ALL EXPOSED DOWNSPOUTS TO BE PT 6.X (FACTORY FINISH).

10. ROOF TOP VENTS, COWLS, FLUES AND ASSOCIATED FLASHINGS TO BE PT 6.X.

11. ALL FIBER CEMENT SOFFIT BOARD TO BE PT 6.X.

12. EXPOSED STEEL LINTELS SUPPORTING MASONRY TO BE PT 6.X.

13. STEEL AT ENTRY CANOPIES TO BE PT 6.X.

EXTERIOR FINISH GENERAL NOTES

LEVEL 1100'-0"

RESIDENCE ROOF109'-4"

GARAGE ROOF111'-0"

GARAGE LEVEL102'-0"

STRUCTURE BEYOND REMOVED FOR CLARITY

LEVEL 1100'-0"

RESIDENCE ROOF109'-4"

GARAGE ROOF111'-0"

GARAGE LEVEL102'-0"

3

A4.04

EXISITNG STRUCTURE BEYOND REMOVED FOR CLARITY

A4.01

7

A4.01 6

A4.01 5

A4.01

4

A4.013

A4.01

2

A4.011

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121P:206.441.4522

CHECKED

DRAWN

DATE

REVISIONS

NAC NO

© 2

01

9 N

AC

in

c

nacarchitecture.com

10/27/2020 6:26:32 AM D:\_Revit\Cascadia-AdditionAndRemodel_AVacek.rvt

10-19-2020

AV

A4.01

121-18031

CA

SC

AD

IA S

CH

OO

L

42

39

16

2N

D A

VE

NE

, R

ED

MO

ND

, W

A, 9

80

52

KF

PE

RM

IT S

ET

EA

ST

BU

ILD

ING

RE

MO

DE

L A

ND

AD

DIT

ION

EXTERIOR

ELEVATIONS

Scale: 1/8" = 1'-0"6WEST ENTRY ELEVATION

Scale: 1/8" = 1'-0"7SOUTH ELEVATION

Scale: 1/8" = 1'-0"3SOUTHEAST ELEVATION

Scale: 1/8" = 1'-0"2SOUTHWEST ELEVATION

Scale: 1/8" = 1'-0"1NORTHWEST ELEVATION

Scale: 1/8" = 1'-0"4NORTH ELEVATION

Scale: 1/8" = 1'-0"5WEST ELEVATION

Scale: 1" = 20'-0"

KEY PLAN

Z01Z01

Z01

New BuildingAddition

Z01Z01

Z01

E01

E01

E01

E01

E01

DE-ENERGIZE AND ABANDON EXG BURIED PWR CCT FOR EXG SITE LTG

1#10,1#10N,1#10G,1"C

PROVIDE TRENCHING TO EXG LTG

COORD BOLLARD LOCATION WITH NEW STORM LINE

COORD BOLLARD LOCATION WITH NEW FIRE WATER LINE

VIA LCM

LN1: 53

VIA LCM

E

E

R

R

R

REMOVE EXG LTG

LN1: 55

© 2

02

0 N

AC

Inc

CHECKED

DRAWN

DATE

NAC NO

nacarchitecture.com

REVISIONS

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121

P:206.441.4522

2025 FIRST AVE | SUITE 300

SEATTLE WA 98121

P:206.441.4522

nacarchitecture.com

10/26/2020 6:42:33 PM D:\_Revit\Cascadia-AdditionAndRemodel_Elec_2019_bputt.rvt

10-19-20

BP, KW

E1.02

121-18031

JR

ELECTRICAL

SITE/PHOTOMETRICS

PLAN

CA

SC

AD

IA S

CH

OO

L

42

39

16

2N

D A

VE

NE

, R

ED

MO

ND

, W

A, 9

80

52

EA

ST

BU

ILD

ING

RE

MO

DE

L A

ND

AD

DIT

ION

PE

RM

IT S

ET

10-19-20

N

Scale 1" = 20'-0"

SITE LIGHTING PHOTOMETRICS PLAN

N

Scale 1" = 20'-0"

SITE LIGHTING PLAN

Application LED bollard with unshielded symmetric light distribution. Designed for landscapes, pathways, and open spaces, these robust luminaires can delineate and structure exterior spaces. Provided with mounting system that allows the luminaire to be adjusted independent of anchor bolt orientation.

Materials Luminaire housing constructed of die-cast and extruded marine grade, copper free (≤ 0.3% copper content) A360.0 aluminum alloy White acrylic diffuser High temperature silicone gasket Mechanically captive stainless steel fasteners

NRTL listed to North American Standards, suitable for wet locations Protection class IP 65 Weight: 40.2 lbs

Electrical Operating voltage 120-277V AC Minimum start temperature -30° C LED module wattage 32.0 W System wattage 36.0 W Controllability 0-10V dimmable Color rendering index Ra > 80 Luminaire lumens 2838 lumens (3000K) Lifetime at Ta = 15° C 105,000 h (L70) Lifetime at Ta = 50° C 58,000 h (L70)

LED color temperature

4000K - Product number + K4 3500K - Product number + K35 3000K - Product number + K3 2700K - Product number + K27

BEGA can supply you with suitable LED replacement modules for up to 20 years after the purchase of LED luminaires - see website for details

Finish All BEGA standard finishes are matte, textured polyester powder coat with minimum 3 mil thickness.

Available colors Black (BLK) White (WHT) RAL: Bronze (BRZ) Silver (SLV) CUS:

Bollard - unshielded

BEGA 1000 BEGA Way, Carpinteria, CA 93013 (805) 684-0533 [email protected] to the dynamic nature of lighting products and the associated technologies, luminaire data on this sheet is subject to change at the discretion of BEGA North America. For the most current technical data, please refer to bega-us .com © copyright BEGA 2018 Updated 09/10/18

Type:BEGA Product:Project:Modified:

Bollard · unshielded

LED A B Anchorage

84 668 32.0 W 8 5⁄8 47 1⁄4 79 818

B

A

84668-K35-BLK

Type Z01

Z01

Page 1 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface MountThe Slot LED family of luminaires offers an unparalleled package of performance and features for your next lighting project. Precision lumen DIRECTIR optics deliver optimized light where needed for ceilings and walls. With other key features such as simplified installation, seamless controls integration and superior LED color constancy, the Slot LED family from Mark Lighting offers exceptional quality and design flexibility.

Technical Drawing

Type:

Project:

Catalog Number:DO NOT TYPE HERE. Autopopulated field.

HousingNominal 3.5” x 3.75” extruded aluminum housing FinishWhite, Black or Silver powdercoat ReflectorFormed steel with high reflectance white.Distribution/ShieldingExtruded 90% transmissive acrylic lens with a textured surface providing diffuse illumination and a uniform appearance for direct lambertian distribution (No Optics). Wall Wash (WW) and Wall Graze (WG) distribution options incorporate co-extruded lenses. Shielding is available as an external blade louver for WW or WG options, or an internal blade louver in lieu of lambertian distribution diffuser.LED ComponentsLinear: Nichia®- 757 series LED chips (>80 CRI)ElectricalLong-life LEDs, coupled with high-efficiency drivers, provide superior quantity and quality of illumination for extended service life. 80% LED lumen maintenance at 60,000 hours (L80/60,000).Color ConsistencyThe Acuity Brands circuit boards for the linear LED components use a precise binning algorithm which creates a consistent color temperature from board to board. The color a variation of no greater than a 2.5 Step MacAdam (2.5SDCM) along the black body locus from board to board.DrivereldoLED® driver provides natural dimming with smooth, continuous and flicker-free deep dimming. Supports operation between 120VAC and 277 VAC, with low inrush current (NEMA 410) and THD < 20%. Meets FCC Title 47 C.F.R. 15 Class A or Class B requirements. Lutron high performance driver options also available.Certification CSA tested to UL 1598 standards, assembled in the USA. Damp location listed.Listings DesignLights Consortium® (DLC) Premium qualified product. Not all versions of this product may be DLC Premium qualified. Please check the DLC Qualified Products List at www.designlights.org/QPL to confirm which versions are qualified.Warranty5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspxNote: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice.

Specification Features

Direct Surface

3 1/2

3 3/4

4FT INDIVIDUAL (35K) DIRECT

Lumens Output 400LMF 600LMF 800LMF 1000LMF

Delivered Lumens 1800 2707 3571 4103

Input Watts 15.4 23.4 32 37.3

Lumen/Watt 117 115 112 110

Fixture Performance

* Consult factory for customized lumen output and wattage between 350LMF and 1050LMF.

A+ Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning.

• All configurations of this luminaire meet the Acuity Brands’ specification for chromatic consistency

• This luminaire is part of an A+ Certified solution for nLight® control networks when ordered with drivers marked by a shaded background*

• This luminaire is part of an A+ Certified solution for nLight control networks, providing advanced control functionality at the luminaire level, when selection includes driver and control options marked by a shaded background*

To learn more about A+, visit www.acuitybrands.com/aplus.

*See ordering tree for details

Type Z02

Page 2 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

A+ Capable options indicated by this color background.

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

Ordering Example: S4LS 32FT MSL8 90CRI 40K 1000LMF DARK EGLD 120 WHT ZT

Series Plan Total Run LengthMax Section Length

Direct Light Source Color Rendering

Direct LED Color Temp Direct LED Light Output

Direct Distribution (Optics)

S4LS Slot 4 Surface - Direct

LCB Linear center balanced

LLP Linear longest possible

_FT Specify continuous run length (in whole feet, 2' minimum)

Unit length may affect available options. 2’ & 3’ only available as individual units

For runs longer than 8FT: ALWAYS order the run by the TOTAL RUN LENGTH. Ordering the sections individually will not provide the correct joining hardware to allow connection in the field.

MSL4 4’

MSL5 5’

MSL6 6’

MSL7 7’

MSL8 8’

80CRI 80 CRI

90CRI 90 CRI

27K 2700K

30K 3000K

35K 3500K

40K 4000K

50K 5000K

400LMF 400 lumens per FT

600LMF 600 lumens per FT

800LMF 800 lumens per FT

1000LMF 1000 lumens per FT

_LMF 1 # lumens per FT

(blank) Standard lambertian distribution

WW 2 Wallwash distributions

WG Wall graze distribution

WW and WG not available with Downlights, EGLD, LVRR or LVRRA.

Downlight Downlight Shape Downlight Color Rendering Downlight Color Temp Minimum Dimming Level Switching Optional Shielding

(blank) No Downlight modules in fixture

2DL LED downlights (2 per unit)

_DL LED downlights per run (3DL, 4DL, etc.)

(blank) No downlight modules in fixture

RDD Round

SQD Square

(blank) No downlight modules in fixture

S80CRI 80 CRI

(blank) No downlight modules in fixture

S27K 2700K

S30K 3000K

S35K 3500K

S40K 4000K

NODIM 3 Non-dimming

MIN1 Constant current, dimming to 1%

DARK Constant current, dimming to 0.1%

SCT Single circuit

DCT 4 Dual circuit

(blank) No louver

LVRD 5 Dropped louver

LVRR 7 Regressed louver painted to match fixture finish

LVRRA 7 Regressed louver, aluminum finish

EGLD 5,6 Edge View direct lens

Not available with Downlights. Not available with NLTAIR2.

Must select all Downlight options.Specify number of downlights modules.Not available on 2’ or 3’ units. Not available with 347V.Maximum of 2DL in 4’ & 5’ units.

Maximum of 3DL in 6’, 7’ & 8’ units.Not available with emergency options.Not available with 4’ unit with DCT.Not available with any sensors on the same unit.

Voltage Finish Emergency Options Control Input Sensor Secondary Sensor

MVOLT Multi-volt, 120-277V

120 120V

277 277V

347 8 347V

WHT White (gloss)

BLK Black (gloss)

SLV Silver (gloss)

WHTT White (textured)

BLKT Black (textured)

SLVT Silver (textured)

RALTBD RAL paint finishes

E10WLCP 9 4' emergency section w/battery pack, 1250 lumens

_E10WLCP 9 4' emergency section w/battery pack, 1250 lumens

_EC 10 # of emergency circuits

BGTD 11 Generator transfer device

Not available with 347V.

(blank) Non-dimming, line voltage

ZT 0-10V control

NLIGHT 12 nLight enabled

NLTAIR2 13 nLight AIR (wireless) enabled

DALI 14,15 DALI compatible

DMX 14,15 DMX compatible

ECOD 15,16,17 Lutron Hi-Lume digital driver

ECOD2 15,16,18 Lutron Hi-Lume 2-wire (1% dimming)

ECOD5 15,16,17 Lutron 5-series digital driver (5% dimming)

(blank) Select if single zone/no zone without sensor

NS Select if multi-zone fixture with no sensor in main zone

PDT_ 19 Occupancy sensor - dual technology (passive infrared & microphonics)

ADC_ 19 Photocell-daylight dimming sensor

API_ 20 PIR occupancy sensor & photocell

APD_ 20 PDT occupancy sensor & photocell

Not available with Downlights.Not available on 2’ or 3’ units.Not available with 347V & nLight. (Use ZT or NLTAIR2 Control Inputs where applicable.)

(blank) No additional zones/sensors

SNS Select if multi-zone fixture with no sensor in secondary zone

SPDT_ 19 Occupancy sensor - dual technology (passive infrared & microphonics)

SADC_ 19 Photocell-daylight dimming sensor

SAPI_ 20 PIR occupancy sensor & photocell

SAPD_ 20 PDT occupancy sensor & photocell

Not available with Downlights.Not available on 2’ or 3’ units.Not available with 347V & nLight. (Use ZT or NLTAIR2 Control Inputs where applicable.)

Tertiary Sensor Options

(blank) No additional zones/sensors

TNS Select if multi-zone fixture with no sensor in tertiary zone

GLR 15 Fast-blow fuse

GMF 15 Slow-blow fuse

WL 15 Wet Location

DPL Damp Location

USPOM US point of assembly

Notes:1. Limited to 400LMF to 1000LMF in 50LMF increments. Not available

with ECOD, ECOD2, ECOD5 or DMX control input. 2. Not available with NLTAIR2.3. Not available with Control Inputs.4. Not available with 2’ or 3’ units, DMX or NLTAIR2. Not available

with E10WLCP on 4’ unit.5. Not available with Sensor Options.6. Not available with Emergency Options7. Not available with sensors on 2’, 3’ & 4’ units.8. DCT not available with 2’ & 3’ units with 347, with ZT & sensors,

with NLTAIR2, with emergency options, with NLIGHT/PP in 5’ units, with NLIGHT/PP & downlights.

9. Not available with 2’ or 3’ units, or 4’ with DCT. Not available with DMX control option. One battery pack per unit. Only available on 8’ unit with ECOD, ECOD2, ECOD5. Not available on 5’ unit with NLTAIR. If with SCT, ZT & API or APD, only available in 7’ & 8’ units. Not available with DCT & sensors. Not available with DCT & nLight in same unit.

10. Powers entire direct unit. Not available with DCT & sensors. Not available with DCT & NLTAIR2. Not available with DMX.

11. Must select 120 or 277 volt. Remote mounted. Not available with sensors. Not available with DCT & NLTAIR2. Not available with DMX.

12. Comes with white CAT5 cord in addition to the standard power cord. Will require remote mounted nIO on 2’ unit.

13. Must select MIN1 or DARK Dim Level. Not available with WW or DCT options on 2’ or 3’ units. If ordered with E10WLCP, only available in 7’ & 8’ units.

14. Must select DARK Dim Level.15. Not available with 347V.16. Must select MIN1 Dim Level. Not available on 2’, 3’ or 5’ units.17. Not available with 347v on 2’, 3’, 5’ or 6’ units.18. 120V only.19. Requires ZT or NLIGHT Control Input.20. Requires ZT, NLIGHT or NLTAIR2 Control Input.

S4LS-LCB-4FT-MSL4-80CRI-35K-6+00LMF-MIN1-SCT-WL

WL

BLKMVOLT

SCTMIN1

600LMF35K80CRIMSL44FTLCBS4LS

Page 3 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

Shielding

Co-Extruded WGCo-Extruded WG

Co-Extruded WG (Standard)

Co-Extruded WG(Standard)

Co-Extruded WWCo-Extruded WW

Co-Extruded WW (Standard)Co-Extruded WW

(Standard)

Edge View Lens (Optional)

Edge Glow Lens(Standard)

Edge View LensEdge Glow Lens

External Louver WW (Painted to Match Housing)

External Louver WW(Painted to Match Housing)

External LouverExternal Louver

Regressed Louver (Natural Aluminum or Painted to Match

Housing)

Regressed LouverRegressed Louver

PHOTOMETRICS

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

Test Report: ISF 37228P0 IES LM 79-08S4LD 4FT 80CRI 30K 400LMFLumens: 1730Wattage: 15.37WEfficacy: 112.5

Zonal Lumen SummaryZone Lumens % Luminaire0-30 472.9 27%0-40 773 44.70%0-60 1359.4 78.60%60-90 370 21.40%70-100 159 9.20%90-120 0.3 0%0-90 1729.4 100%90-180 0.6 0%0-180 1730 100%

Angl

e Candlepower DistributionPlane

0 22.5 45 67.5 90 112.5 135 157.5 1800 591 591 591 591 591 591 591 591 5915 580 589 597 594 597 596 596 595 588

10 574 584 590 591 592 593 594 592 58315 565 576 579 582 585 584 587 583 57720 552 559 567 569 573 572 573 570 56025 532 539 549 549 551 549 551 552 54130 501 509 515 514 519 520 519 518 50935 466 473 480 480 479 480 484 483 47540 427 436 443 441 443 441 443 443 43445 388 394 400 401 401 400 405 402 39650 346 353 355 356 356 355 358 360 35155 302 310 310 310 313 309 316 314 30560 254 263 262 261 261 261 262 266 25965 208 214 213 212 213 213 214 217 21070 162 165 165 166 167 165 164 165 16175 116 118 116 117 117 116 116 116 11580 69 70 71 72 72 72 71 70 6985 30 32 32 33 33 32 30 29 2790 1 2 0 0 0 1 0 1 1

Test Report: ISF 37775P0 IES LM 79-08S4LD 4FT 80CRI 30K 400LMF WWLumens: 1138Wattage: 14.51WEfficacy: 78.4

Zonal Lumen SummaryZone Lumens % Luminaire0-30 424.2 37.30%0-40 657.7 57.80%0-60 1003.1 88%60-90 134.9 11.90%0-90 1138 100.00%

Angl

e Candlepower DistributionPlane

0 22.5 45 67.5 90 112.5 135 157.5 1800 509 509 509 509 509 509 509 509 5095 730 708 659 590 509 433 371 337 326

10 922 898 813 676 501 351 256 214 20215 1008 989 916 743 489 283 184 147 13820 961 970 949 783 471 232 142 115 10925 828 862 914 797 448 192 115 99 9630 673 713 823 779 421 159 99 90 8835 533 569 698 727 383 134 89 83 8140 426 453 568 639 341 114 82 76 7545 337 362 457 529 291 98 75 69 6850 261 282 356 415 237 85 66 62 6255 201 214 274 308 182 73 57 54 5460 151 159 202 219 133 60 47 45 4565 109 115 142 148 91 46 38 36 3570 75 78 94 95 61 34 28 26 2675 46 48 57 56 36 22 18 18 1880 24 26 30 28 18 12 12 11 1185 8 9 10 10 8 6 6 6 590 1 2 1 2 2 2 2 2 2

Page 4 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

Individual Fixture Configurations

Run Configurations

BOR FIXTURE INT FIXTURE EOR FIXTURE

RUN LAYOUT (MOUNTING)LENGTH "A-1" O.A.L. "B" O.C. "C" FROM END

4FT5FT6FT7FT8FT

4'-0 5/16"5'-0 5/16"6'-0 5/16"7'-0 5/16"8'-0 5/16"

4'-0"5'-0"6-0"7'-0"8'-0"

13/16"13/16"13/16"13/16"13/16"

"A-2" O.A.L.4'-0"5'-0"6'-0"7'-0"8'-0"

INDIVIDUAL UNITS (MOUNTING)LENGTH "A" O.A.L. "B-1" O.C. "C" FROM END

2FT3FT4FT5FT6FT7FT8FT

2'-1 1/2"3'-1 1/2"4'-1 1/2"5'-1 1/2"6'-1 1/2"7'-1 1/2"8'-1 1/2"

2" 3/4"3/4"3/4"3/4"3/4"3/4"3/4"

"B-2" O.C.1'-7 1/2"2'-7 1/2"3'-7 1/2"

2"2"2"2"2"2"

4'-7 1/2"5'-7 1/2"6'-7 1/2"7'-7 1/2"

INDIVIDUAL UNITS (MOUNTING)LENGTH "A" O.A.L. "B-2" O.C. "C" FROM END

2FT3FT4FT5FT6FT7FT8FT

2'- 5/8"3'- 5/8"4'- 5/8"5'- 5/8"6'- 5/8"7'- 5/8"8'- 5/8"

1'-7"2'-7"3'-7"4'-7"5-7"6'-7"7'-7"

13/16"13/16"13/16"13/16"13/16"13/16"13/16"

"B-1" O.C.2"2"2"2"2"2"2"

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

LINEAR PLAN:

Mark Lighting offers the ability to provide a continuous run plan to suit your requirements by optionally offering three different methods of configuration.

LLP- Linear Longest PossibleIn this configuration, the longest length available is optimized, resulting in the fewest segments and mounting locations. Caution, should be used where balanced appearance is a concern. Example: 20 FT run would have 2, 8 FT segment and 1, 4 FT segment at the end of the run.

LCB- Linear Center Balanced:This configuration incorporates the longest center segment(s) along with any additional lengths required to fill the run length, added to the run ends. Example: 16 FT run would have 2, 4 FT segments (one at each end) and 1, 8 FT segment in the center.

8 FT 8 FT 4FTLLP

4 FT 8 FT 4FTLCB

This system is not modular. Runs longer that 8FT will be automatically configured with Starter, Middle and Ender sections, based on how you specify the TOTAL RUN LENGTH and MAXIMUM SECTION LENGTH parameters in the ordering information. Always order the total run length, not the individual sections

32FT

8FT 8FT 8FT 8FT

Example: This run must be ordered as 1pc "S4LS LLP 32FT MSL8..."

PRIMARY ZONE:ADC (DAYLIGHT SENSOR). SINCE THERE IS NO NUMBER AFTER THE ADC SENSOR NOMENCLATURE, THE SENSOR WILL CONTROL THE ENTIRE RUN.

TOTAL RUN LENGTH

The run will be broken out using as many sections at the chosen MSL length as possible. Shorter sections will then complete the desired run length.

Examples: S4LS LLP 21FT MSL5... = 5FT / 4FT / 4FT / 4FT / 4FTS4LS LLP 21FT MSL6... = 6FT / 6FT / 5FT / 4FTS4LS LLP 21FT MSL7... = 7FT / 7FT / 7FTS4LS LLP 21FT MSL8... = 8FT / 8FT / 5FT

8FT

MAXIMUM SECTION LENGTH

8FT 8FT 8FT

Example: If you order as 4pcs "S4LS LLP 8FT MSL8... you will receive these INDIVIDUAL sections that cannot be joined together

Page 5 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

Run Patterns, Corners and JunctionSlot 4 LED patterns be configured in 1’ increments with illuminated 90° inside and outside corners, T junctions, and X junctions with standard 2’ corner and junction lengths. For custom angles, corner or junction lengths, consult factory.See separate pattern spec sheet for details.

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

X JunctionT Junction90° Corner

Page 6 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

DownlightsOptional downlights powered by Xicato Spot Modules are available with 4’, 5’, 6’, and 8’ length luminaires, maximum (2) Xicato downlights per length. Each downlight module is 10W with 700 lumens delivered, 28 degree beam spread.. Downlights are supplied with a dedicated feed point and will be controlled separately.

Square Downlight Plate (SQ)

Round Downlight Plate (RD)

312"

312"

312"

312"

Downlight Module

Joiners AEL Precision Row-Mount 3-step fixture-to-fixture connection method

Step 1: Align

Step 2: Engage

Step 3: Lock

Mounting

Continuous RunsSlot 4 LED continuous rows can be configured in 1’ increments and featuring the AEL precision joiner to create a hairline seam between luminaires, providing a monolithic visual aesthetic. For custom run lengths less than a 1’ increment, consult factory.

Standard Downlight Location

Other Downlight Configuration (consult factory)

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

Our surface product mounts to hard/sheetrock ceilings only. Consult manufacturing for use with a grid ceiling.

Page 7 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

INTEGRATED SENSOR LAYOUT

At the 7.5 ft (2.9 m) hanging height of a typical pendant mount fixture the sensor provides 10 ft (3.05 m) radial detection of small motion. At a 9 ft (2.74 m) hanging height the radius is 12 ft (3.66 m) for small motion.

Adequate for walking motion detection from mounting heights between 7.5 ft (2.29 m) and 20 ft (6.10 m).

Initial detection will occur earlier when walking across sensor’s field of view than when walking directly at sensor.

Initial detection of walking motion into long coverage segment will occur at distances of 2x the mounting height up to 15 ft (4.57 m) and 1.75x up to 20 ft (6.10 m). Lens assembly rotates 15° to enable adjustment in order to line up long segments.

Lens rotates 15° to enable adjustment

1512.510752.50 ft2.5571012.515

4.53.832.51.50.750 m0.751.52.533.84.5

OCCUPANCY DETECTION COVERAGE

Integrated ControlsOptional nLight® integrated controls make Slot LED luminaires addressable- allowing them to digitally communicate with other nLight enabled controls such as dimmers, switches, occupancy sensors and photocontrols. Simply connect all the nLight enabled control devices using standard CAT5 Cabling.

Occupancy Sensor (MSD9N) and/or Photocell (DSCC)

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

32FT

8FT 8FT 8FT 8FT32FT MSL8 RUN WITH 2 SENSORS WITH PRIMARY ZONE 24FT AND SECONDARY ZONE 8FT -- PDT24 SADC8

PRIMARY ZONE:PDT24 (DUAL TECH SENSOR, 24FT ZONE)

32FT

8FT 8FT 8FT 8FT32FT MSL8 RUN WITH 1 SENSOR ALL ONE ZONE -- ADC

PRIMARY ZONE:ADC (DAYLIGHT SENSOR). SINCE THERE IS NO NUMBER AFTER THE ADC SENSOR NOMENCLATURE, THE SENSOR WILL CONTROL THE ENTIRE RUN.

32FT

8FT 8FT 8FT 8FT32FT MSL8 RUN WITH 1 SENSOR ALL ONE ZONE -- PDT16

DOES NOT WORK BECAUSE THE LENGTH OF THE ZONE SPECIFIED (16FT),DOES NOT MATCH THE ENTIRE RUN (32FT)

32FT

8FT 8FT 8FT 8FT32FT MSL8 RUN WITH 2 SENSORS WITH PRIMARY ZONE 20FT AND SECONDARY ZONE 12FT -- PDT20 SADC12

INCORRECT:

NOTE: IF THERE IS ONLY ONE ZONE, LEAVE THE NUMBERS AFTER THE SENSOR NOMENCLATURE BLANK. EXAMPLE: NO PDT16, USE PDT

DOES NOT WORK BECAUSE THE LENGTH OF THE ZONES SPECIFIED (20FT AND 12FT),DOES NOT WORK FOR 8FT FIXTURE SECTIONS, ZONES CANNOT SPLIT A FIXTURE SECTION

PRIMARY ZONE: 20FTSECONDARY ZONE: 12FT

Notes: • Only one sensor per zone • At the most, the entire run can only have 2 sensors (thus 2 sensors zones at the most) • Sensor zone can not split fixture sections • No overlapping zones

CORRECT:

SECONDARY ZONE:SADC (DAYLIGHT SENSOR, 8FT ZONE)

Total Run Length to Order

Total Run Length to Order

For runs longer than 8FT: ALWAYS order the run by the TOTAL RUN LENGTH. Ordering the sections individually will not provide the correct joining hardware to allow connection in the field.

Page 8 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

Choose nomenclature from these columns

Dri

ver

Conf

igur

atio

ns

Minimum Dimming Level Control Input Driver Dimming

Range Notes

NODIM + (blank) = 0-10V Generic Driver - Includes no 0-10V leads from the driver.

MIN10 + ZT = 0-10V Generic Driver 100 to 10% Linear dimming

MIN1 + ZT = 0-10V eldoLED ECOdrive 100 to 1% Formerly (EZ1) nomenclature. Linear dimming

MIN1 + NLIGHT = 0-10V eldoLED ECOdrive 100 to 1% Logarithmic dimming

MIN1 + ECOD2 = Lutron forward phase control 100 to 1% LUTRON Hi-lume 1% 2-wire (model LTEA4U1U)

MIN1 + ECOD5 = Lutron Ecosystem 100 to 5% LUTRON 5-Seires EcoSystem LED Driver (model LDE5)

MIN1 ECOD Lutron Ecosystem 100 to 1% LUTRON Hi-lume 1% EcoSystem LED Driver with Soft-on, Fade-to-Black (model LDE1)

DARK ZT 0-10V eldoLED SOLOdrive 100 to 0.1% Formerly (EZB) nomenclature. Linear dimming

DARK NLIGHT 0-10V eldoLED SOLOdrive 100 to 0.1% Logarithmic dimming

DARK DALI DALI compatible eldoLED SOLOdrive 100 to 0.1% "Compatible with DALI. Formerly (EDB & EDAB)

nomenclature." Logarithmic dimming

DARK DMX DMX compatible eldoLED POWERdrive 100 to 0.1% "Compatible with DMX / Remote Device Management.

Formerly (EXB & EDXB) nomenclature." Linear dimming

Intelligent Luminaire Technology Guide

Choose nomenclature from these columns

Cont

rol /

Sen

sor

Conf

igur

atio

ns

Control Input Sensor Sensor Notes

ZT + API = MSD 7 ADCXIndividual fixture control only. PIR integral occupancy sensor with automatic dimming control photocell. (Old nomenclature: ZT + PIR + ADC)

ZT + APD = MSD PDT 7 ADCXIndividual fixture control only. PDT integral occupancy sensor with automatic dimming control photocell. (Old nomenclature: ZT + PDT + ADC)

NLIGHT + (blank) = nIO EZ PH nLight enabled only. No onboard sensor.

NLIGHT EMG = nIO EZ PH ER Emergency nLight enabled only. No onboard sensor.

NLIGHT + API = nIO EZ PH + nES 7 ADCX nLight nES 7 ADCX PIR integral occupancy sensor with automatic dimming photocell. (Old nomenclature: NLIGHT + PIR + ADC)

NLIGHT + PDT = nIO EZ PH + nES PDT 7 nLight nES PDT 7 dual technology integral occupancy sensor. (Old nomenclature: NLIGHT + PDT)

NLIGHT + APD = nIO EZ PH + nES PDT 7 ADCXnLight nES PDT 7 dual technology integral occupancy sensor with automatic dimming photocell. (Old nomenclature: NLIGHT + PDT + ADC)

NLTAIR2 (blank) RIO EZDL 90D G2 https://www.acuitybrands.com/products/detail/778845/nLight/rIO/Fixture-embedded-nLight-AIR-network-interface

NLTAIR2 API RES7 G2 https://www.acuitybrands.com/products/detail/593899/nLight/RES7-Sensor/nLight-AIR-Fixture-Integrated-Wireless-Sensor

NLTAIR2 APD RES7 PDT G2 https://www.acuitybrands.com/products/detail/593899/nLight/RES7-Sensor/nLight-AIR-Fixture-Integrated-Wireless-Sensor

Page 9 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

Remote BGTD Mounting OptionRecessed in sheetrock ceiling; rod mounted to structure. Consult factory for other ceiling types or canopy options.

6 foot flexible conduit included, BGTD option should be mounted within 6 feet of junction box above fixture.

Accessible Ceiling

Page 1 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface MountThe Slot LED family of luminaires offers an unparalleled package of performance and features for your next lighting project. Precision lumen DIRECTIR optics deliver optimized light where needed for ceilings and walls. With other key features such as simplified installation, seamless controls integration and superior LED color constancy, the Slot LED family from Mark Lighting offers exceptional quality and design flexibility.

Technical Drawing

Type:

Project:

Catalog Number:DO NOT TYPE HERE. Autopopulated field.

HousingNominal 3.5” x 3.75” extruded aluminum housing FinishWhite, Black or Silver powdercoat ReflectorFormed steel with high reflectance white.Distribution/ShieldingExtruded 90% transmissive acrylic lens with a textured surface providing diffuse illumination and a uniform appearance for direct lambertian distribution (No Optics). Wall Wash (WW) and Wall Graze (WG) distribution options incorporate co-extruded lenses. Shielding is available as an external blade louver for WW or WG options, or an internal blade louver in lieu of lambertian distribution diffuser.LED ComponentsLinear: Nichia®- 757 series LED chips (>80 CRI)ElectricalLong-life LEDs, coupled with high-efficiency drivers, provide superior quantity and quality of illumination for extended service life. 80% LED lumen maintenance at 60,000 hours (L80/60,000).Color ConsistencyThe Acuity Brands circuit boards for the linear LED components use a precise binning algorithm which creates a consistent color temperature from board to board. The color a variation of no greater than a 2.5 Step MacAdam (2.5SDCM) along the black body locus from board to board.DrivereldoLED® driver provides natural dimming with smooth, continuous and flicker-free deep dimming. Supports operation between 120VAC and 277 VAC, with low inrush current (NEMA 410) and THD < 20%. Meets FCC Title 47 C.F.R. 15 Class A or Class B requirements. Lutron high performance driver options also available.Certification CSA tested to UL 1598 standards, assembled in the USA. Damp location listed.Listings DesignLights Consortium® (DLC) Premium qualified product. Not all versions of this product may be DLC Premium qualified. Please check the DLC Qualified Products List at www.designlights.org/QPL to confirm which versions are qualified.Warranty5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspxNote: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice.

Specification Features

Direct Surface

3 1/2

3 3/4

4FT INDIVIDUAL (35K) DIRECT

Lumens Output 400LMF 600LMF 800LMF 1000LMF

Delivered Lumens 1800 2707 3571 4103

Input Watts 15.4 23.4 32 37.3

Lumen/Watt 117 115 112 110

Fixture Performance

* Consult factory for customized lumen output and wattage between 350LMF and 1050LMF.

A+ Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning.

• All configurations of this luminaire meet the Acuity Brands’ specification for chromatic consistency

• This luminaire is part of an A+ Certified solution for nLight® control networks when ordered with drivers marked by a shaded background*

• This luminaire is part of an A+ Certified solution for nLight control networks, providing advanced control functionality at the luminaire level, when selection includes driver and control options marked by a shaded background*

To learn more about A+, visit www.acuitybrands.com/aplus.

*See ordering tree for details

Type Z02

Page 2 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

A+ Capable options indicated by this color background.

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

Ordering Example: S4LS 32FT MSL8 90CRI 40K 1000LMF DARK EGLD 120 WHT ZT

Series Plan Total Run LengthMax Section Length

Direct Light Source Color Rendering

Direct LED Color Temp Direct LED Light Output

Direct Distribution (Optics)

S4LS Slot 4 Surface - Direct

LCB Linear center balanced

LLP Linear longest possible

_FT Specify continuous run length (in whole feet, 2' minimum)

Unit length may affect available options. 2’ & 3’ only available as individual units

For runs longer than 8FT: ALWAYS order the run by the TOTAL RUN LENGTH. Ordering the sections individually will not provide the correct joining hardware to allow connection in the field.

MSL4 4’

MSL5 5’

MSL6 6’

MSL7 7’

MSL8 8’

80CRI 80 CRI

90CRI 90 CRI

27K 2700K

30K 3000K

35K 3500K

40K 4000K

50K 5000K

400LMF 400 lumens per FT

600LMF 600 lumens per FT

800LMF 800 lumens per FT

1000LMF 1000 lumens per FT

_LMF 1 # lumens per FT

(blank) Standard lambertian distribution

WW 2 Wallwash distributions

WG Wall graze distribution

WW and WG not available with Downlights, EGLD, LVRR or LVRRA.

Downlight Downlight Shape Downlight Color Rendering Downlight Color Temp Minimum Dimming Level Switching Optional Shielding

(blank) No Downlight modules in fixture

2DL LED downlights (2 per unit)

_DL LED downlights per run (3DL, 4DL, etc.)

(blank) No downlight modules in fixture

RDD Round

SQD Square

(blank) No downlight modules in fixture

S80CRI 80 CRI

(blank) No downlight modules in fixture

S27K 2700K

S30K 3000K

S35K 3500K

S40K 4000K

NODIM 3 Non-dimming

MIN1 Constant current, dimming to 1%

DARK Constant current, dimming to 0.1%

SCT Single circuit

DCT 4 Dual circuit

(blank) No louver

LVRD 5 Dropped louver

LVRR 7 Regressed louver painted to match fixture finish

LVRRA 7 Regressed louver, aluminum finish

EGLD 5,6 Edge View direct lens

Not available with Downlights. Not available with NLTAIR2.

Must select all Downlight options.Specify number of downlights modules.Not available on 2’ or 3’ units. Not available with 347V.Maximum of 2DL in 4’ & 5’ units.

Maximum of 3DL in 6’, 7’ & 8’ units.Not available with emergency options.Not available with 4’ unit with DCT.Not available with any sensors on the same unit.

Voltage Finish Emergency Options Control Input Sensor Secondary Sensor

MVOLT Multi-volt, 120-277V

120 120V

277 277V

347 8 347V

WHT White (gloss)

BLK Black (gloss)

SLV Silver (gloss)

WHTT White (textured)

BLKT Black (textured)

SLVT Silver (textured)

RALTBD RAL paint finishes

E10WLCP 9 4' emergency section w/battery pack, 1250 lumens

_E10WLCP 9 4' emergency section w/battery pack, 1250 lumens

_EC 10 # of emergency circuits

BGTD 11 Generator transfer device

Not available with 347V.

(blank) Non-dimming, line voltage

ZT 0-10V control

NLIGHT 12 nLight enabled

NLTAIR2 13 nLight AIR (wireless) enabled

DALI 14,15 DALI compatible

DMX 14,15 DMX compatible

ECOD 15,16,17 Lutron Hi-Lume digital driver

ECOD2 15,16,18 Lutron Hi-Lume 2-wire (1% dimming)

ECOD5 15,16,17 Lutron 5-series digital driver (5% dimming)

(blank) Select if single zone/no zone without sensor

NS Select if multi-zone fixture with no sensor in main zone

PDT_ 19 Occupancy sensor - dual technology (passive infrared & microphonics)

ADC_ 19 Photocell-daylight dimming sensor

API_ 20 PIR occupancy sensor & photocell

APD_ 20 PDT occupancy sensor & photocell

Not available with Downlights.Not available on 2’ or 3’ units.Not available with 347V & nLight. (Use ZT or NLTAIR2 Control Inputs where applicable.)

(blank) No additional zones/sensors

SNS Select if multi-zone fixture with no sensor in secondary zone

SPDT_ 19 Occupancy sensor - dual technology (passive infrared & microphonics)

SADC_ 19 Photocell-daylight dimming sensor

SAPI_ 20 PIR occupancy sensor & photocell

SAPD_ 20 PDT occupancy sensor & photocell

Not available with Downlights.Not available on 2’ or 3’ units.Not available with 347V & nLight. (Use ZT or NLTAIR2 Control Inputs where applicable.)

Tertiary Sensor Options

(blank) No additional zones/sensors

TNS Select if multi-zone fixture with no sensor in tertiary zone

GLR 15 Fast-blow fuse

GMF 15 Slow-blow fuse

WL 15 Wet Location

DPL Damp Location

USPOM US point of assembly

Notes:1. Limited to 400LMF to 1000LMF in 50LMF increments. Not available

with ECOD, ECOD2, ECOD5 or DMX control input. 2. Not available with NLTAIR2.3. Not available with Control Inputs.4. Not available with 2’ or 3’ units, DMX or NLTAIR2. Not available

with E10WLCP on 4’ unit.5. Not available with Sensor Options.6. Not available with Emergency Options7. Not available with sensors on 2’, 3’ & 4’ units.8. DCT not available with 2’ & 3’ units with 347, with ZT & sensors,

with NLTAIR2, with emergency options, with NLIGHT/PP in 5’ units, with NLIGHT/PP & downlights.

9. Not available with 2’ or 3’ units, or 4’ with DCT. Not available with DMX control option. One battery pack per unit. Only available on 8’ unit with ECOD, ECOD2, ECOD5. Not available on 5’ unit with NLTAIR. If with SCT, ZT & API or APD, only available in 7’ & 8’ units. Not available with DCT & sensors. Not available with DCT & nLight in same unit.

10. Powers entire direct unit. Not available with DCT & sensors. Not available with DCT & NLTAIR2. Not available with DMX.

11. Must select 120 or 277 volt. Remote mounted. Not available with sensors. Not available with DCT & NLTAIR2. Not available with DMX.

12. Comes with white CAT5 cord in addition to the standard power cord. Will require remote mounted nIO on 2’ unit.

13. Must select MIN1 or DARK Dim Level. Not available with WW or DCT options on 2’ or 3’ units. If ordered with E10WLCP, only available in 7’ & 8’ units.

14. Must select DARK Dim Level.15. Not available with 347V.16. Must select MIN1 Dim Level. Not available on 2’, 3’ or 5’ units.17. Not available with 347v on 2’, 3’, 5’ or 6’ units.18. 120V only.19. Requires ZT or NLIGHT Control Input.20. Requires ZT, NLIGHT or NLTAIR2 Control Input.

S4LS-LCB-2FT-MSL4-80CRI-35K-6+00LMF-MIN1-SCT-WL

WL

BLKMVOLT

SCTMIN1

600LMF35K80CRIMSL44FTLCBS4LS

Page 3 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

Shielding

Co-Extruded WGCo-Extruded WG

Co-Extruded WG (Standard)

Co-Extruded WG(Standard)

Co-Extruded WWCo-Extruded WW

Co-Extruded WW (Standard)Co-Extruded WW

(Standard)

Edge View Lens (Optional)

Edge Glow Lens(Standard)

Edge View LensEdge Glow Lens

External Louver WW (Painted to Match Housing)

External Louver WW(Painted to Match Housing)

External LouverExternal Louver

Regressed Louver (Natural Aluminum or Painted to Match

Housing)

Regressed LouverRegressed Louver

PHOTOMETRICS

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

Test Report: ISF 37228P0 IES LM 79-08S4LD 4FT 80CRI 30K 400LMFLumens: 1730Wattage: 15.37WEfficacy: 112.5

Zonal Lumen SummaryZone Lumens % Luminaire0-30 472.9 27%0-40 773 44.70%0-60 1359.4 78.60%60-90 370 21.40%70-100 159 9.20%90-120 0.3 0%0-90 1729.4 100%90-180 0.6 0%0-180 1730 100%

Angl

e Candlepower DistributionPlane

0 22.5 45 67.5 90 112.5 135 157.5 1800 591 591 591 591 591 591 591 591 5915 580 589 597 594 597 596 596 595 588

10 574 584 590 591 592 593 594 592 58315 565 576 579 582 585 584 587 583 57720 552 559 567 569 573 572 573 570 56025 532 539 549 549 551 549 551 552 54130 501 509 515 514 519 520 519 518 50935 466 473 480 480 479 480 484 483 47540 427 436 443 441 443 441 443 443 43445 388 394 400 401 401 400 405 402 39650 346 353 355 356 356 355 358 360 35155 302 310 310 310 313 309 316 314 30560 254 263 262 261 261 261 262 266 25965 208 214 213 212 213 213 214 217 21070 162 165 165 166 167 165 164 165 16175 116 118 116 117 117 116 116 116 11580 69 70 71 72 72 72 71 70 6985 30 32 32 33 33 32 30 29 2790 1 2 0 0 0 1 0 1 1

Test Report: ISF 37775P0 IES LM 79-08S4LD 4FT 80CRI 30K 400LMF WWLumens: 1138Wattage: 14.51WEfficacy: 78.4

Zonal Lumen SummaryZone Lumens % Luminaire0-30 424.2 37.30%0-40 657.7 57.80%0-60 1003.1 88%60-90 134.9 11.90%0-90 1138 100.00%

Angl

e Candlepower DistributionPlane

0 22.5 45 67.5 90 112.5 135 157.5 1800 509 509 509 509 509 509 509 509 5095 730 708 659 590 509 433 371 337 326

10 922 898 813 676 501 351 256 214 20215 1008 989 916 743 489 283 184 147 13820 961 970 949 783 471 232 142 115 10925 828 862 914 797 448 192 115 99 9630 673 713 823 779 421 159 99 90 8835 533 569 698 727 383 134 89 83 8140 426 453 568 639 341 114 82 76 7545 337 362 457 529 291 98 75 69 6850 261 282 356 415 237 85 66 62 6255 201 214 274 308 182 73 57 54 5460 151 159 202 219 133 60 47 45 4565 109 115 142 148 91 46 38 36 3570 75 78 94 95 61 34 28 26 2675 46 48 57 56 36 22 18 18 1880 24 26 30 28 18 12 12 11 1185 8 9 10 10 8 6 6 6 590 1 2 1 2 2 2 2 2 2

Page 4 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

Individual Fixture Configurations

Run Configurations

BOR FIXTURE INT FIXTURE EOR FIXTURE

RUN LAYOUT (MOUNTING)LENGTH "A-1" O.A.L. "B" O.C. "C" FROM END

4FT5FT6FT7FT8FT

4'-0 5/16"5'-0 5/16"6'-0 5/16"7'-0 5/16"8'-0 5/16"

4'-0"5'-0"6-0"7'-0"8'-0"

13/16"13/16"13/16"13/16"13/16"

"A-2" O.A.L.4'-0"5'-0"6'-0"7'-0"8'-0"

INDIVIDUAL UNITS (MOUNTING)LENGTH "A" O.A.L. "B-1" O.C. "C" FROM END

2FT3FT4FT5FT6FT7FT8FT

2'-1 1/2"3'-1 1/2"4'-1 1/2"5'-1 1/2"6'-1 1/2"7'-1 1/2"8'-1 1/2"

2" 3/4"3/4"3/4"3/4"3/4"3/4"3/4"

"B-2" O.C.1'-7 1/2"2'-7 1/2"3'-7 1/2"

2"2"2"2"2"2"

4'-7 1/2"5'-7 1/2"6'-7 1/2"7'-7 1/2"

INDIVIDUAL UNITS (MOUNTING)LENGTH "A" O.A.L. "B-2" O.C. "C" FROM END

2FT3FT4FT5FT6FT7FT8FT

2'- 5/8"3'- 5/8"4'- 5/8"5'- 5/8"6'- 5/8"7'- 5/8"8'- 5/8"

1'-7"2'-7"3'-7"4'-7"5-7"6'-7"7'-7"

13/16"13/16"13/16"13/16"13/16"13/16"13/16"

"B-1" O.C.2"2"2"2"2"2"2"

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

LINEAR PLAN:

Mark Lighting offers the ability to provide a continuous run plan to suit your requirements by optionally offering three different methods of configuration.

LLP- Linear Longest PossibleIn this configuration, the longest length available is optimized, resulting in the fewest segments and mounting locations. Caution, should be used where balanced appearance is a concern. Example: 20 FT run would have 2, 8 FT segment and 1, 4 FT segment at the end of the run.

LCB- Linear Center Balanced:This configuration incorporates the longest center segment(s) along with any additional lengths required to fill the run length, added to the run ends. Example: 16 FT run would have 2, 4 FT segments (one at each end) and 1, 8 FT segment in the center.

8 FT 8 FT 4FTLLP

4 FT 8 FT 4FTLCB

This system is not modular. Runs longer that 8FT will be automatically configured with Starter, Middle and Ender sections, based on how you specify the TOTAL RUN LENGTH and MAXIMUM SECTION LENGTH parameters in the ordering information. Always order the total run length, not the individual sections

32FT

8FT 8FT 8FT 8FT

Example: This run must be ordered as 1pc "S4LS LLP 32FT MSL8..."

PRIMARY ZONE:ADC (DAYLIGHT SENSOR). SINCE THERE IS NO NUMBER AFTER THE ADC SENSOR NOMENCLATURE, THE SENSOR WILL CONTROL THE ENTIRE RUN.

TOTAL RUN LENGTH

The run will be broken out using as many sections at the chosen MSL length as possible. Shorter sections will then complete the desired run length.

Examples: S4LS LLP 21FT MSL5... = 5FT / 4FT / 4FT / 4FT / 4FTS4LS LLP 21FT MSL6... = 6FT / 6FT / 5FT / 4FTS4LS LLP 21FT MSL7... = 7FT / 7FT / 7FTS4LS LLP 21FT MSL8... = 8FT / 8FT / 5FT

8FT

MAXIMUM SECTION LENGTH

8FT 8FT 8FT

Example: If you order as 4pcs "S4LS LLP 8FT MSL8... you will receive these INDIVIDUAL sections that cannot be joined together

Page 5 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

Run Patterns, Corners and JunctionSlot 4 LED patterns be configured in 1’ increments with illuminated 90° inside and outside corners, T junctions, and X junctions with standard 2’ corner and junction lengths. For custom angles, corner or junction lengths, consult factory.See separate pattern spec sheet for details.

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

X JunctionT Junction90° Corner

Page 6 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

DownlightsOptional downlights powered by Xicato Spot Modules are available with 4’, 5’, 6’, and 8’ length luminaires, maximum (2) Xicato downlights per length. Each downlight module is 10W with 700 lumens delivered, 28 degree beam spread.. Downlights are supplied with a dedicated feed point and will be controlled separately.

Square Downlight Plate (SQ)

Round Downlight Plate (RD)

312"

312"

312"

312"

Downlight Module

Joiners AEL Precision Row-Mount 3-step fixture-to-fixture connection method

Step 1: Align

Step 2: Engage

Step 3: Lock

Mounting

Continuous RunsSlot 4 LED continuous rows can be configured in 1’ increments and featuring the AEL precision joiner to create a hairline seam between luminaires, providing a monolithic visual aesthetic. For custom run lengths less than a 1’ increment, consult factory.

Standard Downlight Location

Other Downlight Configuration (consult factory)

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

Our surface product mounts to hard/sheetrock ceilings only. Consult manufacturing for use with a grid ceiling.

Page 7 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

INTEGRATED SENSOR LAYOUT

At the 7.5 ft (2.9 m) hanging height of a typical pendant mount fixture the sensor provides 10 ft (3.05 m) radial detection of small motion. At a 9 ft (2.74 m) hanging height the radius is 12 ft (3.66 m) for small motion.

Adequate for walking motion detection from mounting heights between 7.5 ft (2.29 m) and 20 ft (6.10 m).

Initial detection will occur earlier when walking across sensor’s field of view than when walking directly at sensor.

Initial detection of walking motion into long coverage segment will occur at distances of 2x the mounting height up to 15 ft (4.57 m) and 1.75x up to 20 ft (6.10 m). Lens assembly rotates 15° to enable adjustment in order to line up long segments.

Lens rotates 15° to enable adjustment

1512.510752.50 ft2.5571012.515

4.53.832.51.50.750 m0.751.52.533.84.5

OCCUPANCY DETECTION COVERAGE

Integrated ControlsOptional nLight® integrated controls make Slot LED luminaires addressable- allowing them to digitally communicate with other nLight enabled controls such as dimmers, switches, occupancy sensors and photocontrols. Simply connect all the nLight enabled control devices using standard CAT5 Cabling.

Occupancy Sensor (MSD9N) and/or Photocell (DSCC)

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

32FT

8FT 8FT 8FT 8FT32FT MSL8 RUN WITH 2 SENSORS WITH PRIMARY ZONE 24FT AND SECONDARY ZONE 8FT -- PDT24 SADC8

PRIMARY ZONE:PDT24 (DUAL TECH SENSOR, 24FT ZONE)

32FT

8FT 8FT 8FT 8FT32FT MSL8 RUN WITH 1 SENSOR ALL ONE ZONE -- ADC

PRIMARY ZONE:ADC (DAYLIGHT SENSOR). SINCE THERE IS NO NUMBER AFTER THE ADC SENSOR NOMENCLATURE, THE SENSOR WILL CONTROL THE ENTIRE RUN.

32FT

8FT 8FT 8FT 8FT32FT MSL8 RUN WITH 1 SENSOR ALL ONE ZONE -- PDT16

DOES NOT WORK BECAUSE THE LENGTH OF THE ZONE SPECIFIED (16FT),DOES NOT MATCH THE ENTIRE RUN (32FT)

32FT

8FT 8FT 8FT 8FT32FT MSL8 RUN WITH 2 SENSORS WITH PRIMARY ZONE 20FT AND SECONDARY ZONE 12FT -- PDT20 SADC12

INCORRECT:

NOTE: IF THERE IS ONLY ONE ZONE, LEAVE THE NUMBERS AFTER THE SENSOR NOMENCLATURE BLANK. EXAMPLE: NO PDT16, USE PDT

DOES NOT WORK BECAUSE THE LENGTH OF THE ZONES SPECIFIED (20FT AND 12FT),DOES NOT WORK FOR 8FT FIXTURE SECTIONS, ZONES CANNOT SPLIT A FIXTURE SECTION

PRIMARY ZONE: 20FTSECONDARY ZONE: 12FT

Notes: • Only one sensor per zone • At the most, the entire run can only have 2 sensors (thus 2 sensors zones at the most) • Sensor zone can not split fixture sections • No overlapping zones

CORRECT:

SECONDARY ZONE:SADC (DAYLIGHT SENSOR, 8FT ZONE)

Total Run Length to Order

Total Run Length to Order

For runs longer than 8FT: ALWAYS order the run by the TOTAL RUN LENGTH. Ordering the sections individually will not provide the correct joining hardware to allow connection in the field.

Page 8 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

Choose nomenclature from these columns

Dri

ver

Conf

igur

atio

ns

Minimum Dimming Level Control Input Driver Dimming

Range Notes

NODIM + (blank) = 0-10V Generic Driver - Includes no 0-10V leads from the driver.

MIN10 + ZT = 0-10V Generic Driver 100 to 10% Linear dimming

MIN1 + ZT = 0-10V eldoLED ECOdrive 100 to 1% Formerly (EZ1) nomenclature. Linear dimming

MIN1 + NLIGHT = 0-10V eldoLED ECOdrive 100 to 1% Logarithmic dimming

MIN1 + ECOD2 = Lutron forward phase control 100 to 1% LUTRON Hi-lume 1% 2-wire (model LTEA4U1U)

MIN1 + ECOD5 = Lutron Ecosystem 100 to 5% LUTRON 5-Seires EcoSystem LED Driver (model LDE5)

MIN1 ECOD Lutron Ecosystem 100 to 1% LUTRON Hi-lume 1% EcoSystem LED Driver with Soft-on, Fade-to-Black (model LDE1)

DARK ZT 0-10V eldoLED SOLOdrive 100 to 0.1% Formerly (EZB) nomenclature. Linear dimming

DARK NLIGHT 0-10V eldoLED SOLOdrive 100 to 0.1% Logarithmic dimming

DARK DALI DALI compatible eldoLED SOLOdrive 100 to 0.1% "Compatible with DALI. Formerly (EDB & EDAB)

nomenclature." Logarithmic dimming

DARK DMX DMX compatible eldoLED POWERdrive 100 to 0.1% "Compatible with DMX / Remote Device Management.

Formerly (EXB & EDXB) nomenclature." Linear dimming

Intelligent Luminaire Technology Guide

Choose nomenclature from these columns

Cont

rol /

Sen

sor

Conf

igur

atio

ns

Control Input Sensor Sensor Notes

ZT + API = MSD 7 ADCXIndividual fixture control only. PIR integral occupancy sensor with automatic dimming control photocell. (Old nomenclature: ZT + PIR + ADC)

ZT + APD = MSD PDT 7 ADCXIndividual fixture control only. PDT integral occupancy sensor with automatic dimming control photocell. (Old nomenclature: ZT + PDT + ADC)

NLIGHT + (blank) = nIO EZ PH nLight enabled only. No onboard sensor.

NLIGHT EMG = nIO EZ PH ER Emergency nLight enabled only. No onboard sensor.

NLIGHT + API = nIO EZ PH + nES 7 ADCX nLight nES 7 ADCX PIR integral occupancy sensor with automatic dimming photocell. (Old nomenclature: NLIGHT + PIR + ADC)

NLIGHT + PDT = nIO EZ PH + nES PDT 7 nLight nES PDT 7 dual technology integral occupancy sensor. (Old nomenclature: NLIGHT + PDT)

NLIGHT + APD = nIO EZ PH + nES PDT 7 ADCXnLight nES PDT 7 dual technology integral occupancy sensor with automatic dimming photocell. (Old nomenclature: NLIGHT + PDT + ADC)

NLTAIR2 (blank) RIO EZDL 90D G2 https://www.acuitybrands.com/products/detail/778845/nLight/rIO/Fixture-embedded-nLight-AIR-network-interface

NLTAIR2 API RES7 G2 https://www.acuitybrands.com/products/detail/593899/nLight/RES7-Sensor/nLight-AIR-Fixture-Integrated-Wireless-Sensor

NLTAIR2 APD RES7 PDT G2 https://www.acuitybrands.com/products/detail/593899/nLight/RES7-Sensor/nLight-AIR-Fixture-Integrated-Wireless-Sensor

Page 9 S4LS SURFACE 08/19/19

marklighting.com | 800-705-SERV (7378) | ©2014-2019 Acuity Brands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

MARK ARCHITECTURALLIGHTING TM

Slot 4 LED Surface Mount

Remote BGTD Mounting OptionRecessed in sheetrock ceiling; rod mounted to structure. Consult factory for other ceiling types or canopy options.

6 foot flexible conduit included, BGTD option should be mounted within 6 feet of junction box above fixture.

Accessible Ceiling

Everly LED Outdoor SconceEVYW Series

Features This outdoor LED light is ideal for security and general lighting.Available in 1-light and 2-light. Provides lighting in residential, commercial, and hospitality applications.Fixture mounts to standard junction box (not included).

Construction Standard mounting holes and hardware are included. Power supply connections must be made inside a junction box (not included).

Finish Black powder coated finish.

Diffuser Clear diffuser.

Electrical This unit is direct wired with a low voltage electronic LED driver.The constant current LED driver is rated for 120-277 VAC input,Minimum starting temp -20°F.

LampingFixture includes a LED modules capable of producing:8” - 12W, 1000 source lumens12” - 24W, 1800 source lumens3000K (CCT). Rated for 50,000 Hrs. 90 CRI.

Certification All fixtures are cETLus listed for wet locations.

Warranty Limited warranty: This fixture is free fromdefects in materials and workmanship fora period of 5 years from date of purchase.

Specifications and dimensions subject to change without notice.

2345 N. Ernie Krueger Circle • Waukegan, IL. 60087 • P: 847.249.5970 • F: 847.249.2618 • AFXinc.com R0/18

DATELOCATION

PREPAREDBY

COMMENTS

CATALOG NUMBER

QUANTITY

FIXTURE TYPE

Ordering Information:Black LED Lumens CCT H W D EVYW070410L30MVBK (1-Light) 12W 1000 3000K 8” 4-1/4” 7”EVYW070418L30MVBK (2-Light) 24W 1800 3000K 12” 4-1/4” 7”

Source

1-Light

2-Light

EVYW070410L30MVBK

Type Z03

>2025 First Avenue, Suite 300, Seattle, WA 98121-3131 206 441 4522 / nacarchitecture.com

Seattle / Spokane / Los Angeles

Cascadia Montessori School

East Building Remodel and Addition

Roof Plan Waiver

Cascadia Montessori School Remodel and Addition is proposing no rooftop mechanical equipment

resulting in no rooftop mechanical equipment screening.

A waiver is requested for the Roof Plan.