SHDTU03-ET100/Ethernet Modem
Installation and Operation Manual
Version 1.0
RReevviissiioonn MMaarrkkss
Revision Date Notes
V 1.0 2006.7 Software: Version: 2.04 FW 1.16
8/2/2019 Shdtu03 Et100 Man
4/48
8/2/2019 Shdtu03 Et100 Man
5/48
Table of Contents
i
Chapter 1. Introduction ......................
I. Features ........ 1-1
II. Specification 1-2
III. Application. ... 1-3
Chapter 2. Hardware Installation ....................
I. Front Panel .......... 2-1
II. Rear Panel... 2-3III. Hardware Installation ... 2-4
Chapter 3. What's Auto Configuration ....................
I. Wet Current .......... 3-1
Chapter 4. Configuration with Keypad and LCD ..I. Purpose ............ 4-1
II. How to use key pads ?..... 4-1
III. Menu Tree ..... 4-2
1. Menu tree for SHOW STATUS.... 4-3
2. Menu tree for SHOW STATISTIC....... 4-4
3. Menu tree for SETUP TYPE and SHDSL .. 4-54. Menu tree for SETUP REMOTE CONFIG 4-6
5. Menu tree for SAVE CONFIGURATION.... 4-7
8/2/2019 Shdtu03 Et100 Man
6/48
Table of Contents
ii
Chapter 5. Configuration with Console Port ....
I. Login Procedure ......... 5-1
II. Window structure....... 5-2
III. System Management Terminal(SMT) ..... 5-3
1. Menu Command .......... 5-3
2. Navigating the SMT interface.......... 5-4
IV. Main Menu Summary .. 5-5
V. Configuration the SHDSL NTU ... 5-61. Configure SHDSL type.... 5-7
2. Configure SHDSL parameters......... 5-8
3. Configure Remote parameters .... 5-11
4. Restore factory default .... 5-11
VI. Write the setup parameters... 5-12
VII. Reboot the SHDSL NTU..... 5-13VIII. View the system status ..... 5-14
IX. View the system configuration .... 5-16
X. Upgrade the SHDSL NTU..... 5-17
XI. EXIT SMT ... 5-19
Appendix I .................................. A-1Appendix II .... A-2
I. Connector Architecture ... A-2
Appendix III ...... A-4
I. Cable Connection ... A-4
8/2/2019 Shdtu03 Et100 Man
7/48
Chapter 1. Introduction
1-1
II.. FFeeaattuurreess
The SHDSL NTU offers customers premises to Bridged Ethernet serviceswith an RJ-45 interface. Utilizing standard HDLC encapsulation, the SHDSLNTU offers WAN data rates up to 2.304Mbps.
The SHDSL NTU can be configured and managed via EOC, or menu-drivenVT100 compatible Asynchronous Terminal Interface, either locally orremotely.
The SHDSL NTU is equipped with an auto rate capability that identifies themaximum line rate supported by the copper loop. This powerful automaticconfiguration capability makes installation and service provisioning simpleand painless. Further flexibility is provided in the ability to manually set themaximum NTU speed at different levels for different customer-tailoredservice offerings.
Standard G.shdsl (ITU G.991.2) supports improved reach/speed andgreater interoperability
Fast and cost-effective provisioning of Ethernet services Uses existing copper loop infrastructures Can operate in back to back connection Efficient single wire pair usage Up to 2.3Mbps symmetric service bit rate Auto rate installation maximizes data rate based on loop conditions Local management interface with LCD display Remote line loopback SHDSL Line performance monitoring
Raw and per time interval statistics Bandwidth guaranteed transmission equipment
8/2/2019 Shdtu03 Et100 Man
8/48
Chapter 1. Introduction
1-2
IIII.. SSppeecciiffiiccaattiioonnNetwork Interface
Line Rate: SHDSL per ITU G.991.2 Coding: trellis coded pulse amplitude modulation (PAM) Support: ANSI (Annex A) and ETSI (Annex B) Payload rates: 64kbps to 2.304Mbps (N x 64kbps N=1 to 36) Connection: RJ-45 jack (2-wire)
Ethernet Interface
Payload rates: 64kbps to 2.304Mbps (N x 64kbps N=1 to 36) IEE802.3/802.3u 10/100Base-TX Standard HDLC WAN encapsulation
DSL Timing Network / Internal
Performance Monitoring ES, SES, UAS, Alarms, Errors for SHDSL
Loopback Tests Local Loopback Digital Loopback Remote Loopback Build-in 211-1 bit tester
Management Configuration with keypad and LCD display
Console port Supports firmware upgrade
Physical/Electrical Dimensions: 19.5 x 4.8 x 16.8 cm Input: 90~240VAC with 50~60Hz (AC Model) Power Consumption: 10W Max Operation: 0 to 50C ; Humidity: Up to 95% (non-condensing)
!
Warning! High voltage. Do not open
8/2/2019 Shdtu03 Et100 Man
9/48
Chapter 1. Introduction
1-3
IIIIII.. AApppplliiccaattiioonn
The SHDTU03-ET100 provides synchronous transmissions at data rates of
64Kbps up to 2304kbps utilizing an HDLC bridge over TDM based SHDSL.
8/2/2019 Shdtu03 Et100 Man
10/48
Chapter 1. Introduction
1-4
This page is left in blank intentionally
8/2/2019 Shdtu03 Et100 Man
11/48
Chapter 2. Hardware Installation
2-1
This chapter shows the front panel and how to install the hardware.
I. Front PanelThe front panel contains LED status
The LCD can show the status and configuration of the product. Thelocal management interface will be done by push button keys and LCDdisplay. For more detail, refer to Chapter 4: Configuration.
The purpose of key pad is to configure the SHDSL NTU. Review
Chapter 4 for detail configuration.
Key Pad Description
ESC Return to previous configuration menu.
Enter Skip to next configuration menu or configure the items.
L Select other parameter in the same level menu.
R Select other parameter in the same level menu.
8/2/2019 Shdtu03 Et100 Man
12/48
Chapter 2. Hardware Installation
2-2
The following table describes the LEDs function of the SHDTU03.
LED Color Action Description
On Power is on.POWER Green
Off Power is off.
On Major alarm has occurred.ALARM Red
Off System is working normally.
On System is testing for connection.
System
TEST YellowOff System is working normally.
On SHDSL line is connected.
Blink Data transmit in SHDSL line.SYNC Green
Off SHDSL line has dropped.
Blink There are error seconds.
ERROR RedOff There are not any error seconds.
On Loopback is on.
G.SHDSL
LBK Yellow
Off Loopback is off.
On Ethernet has link
Blink Ethernet has activity and linkLink/Act Green
Off Ethernet is not linked
On Ethernet is 100Base-TX100M Green
Off Ethernet is 10Base-T
Blink Ethernet collisions are occuring
Ethernet
Col Yellow
Off No collisions are occuring
8/2/2019 Shdtu03 Et100 Man
13/48
Chapter 2. Hardware Installation
2-3
IIII.. RReeaarr PPaanneellFrom left to right, the rear panel of SHDSL NTU includes the power
switch, power socket, RJ-45 for console cable, DB25 interface is V.35 in theV.35 model or may be V.35, X.21, RS-530 or RS-449 in the SERIAL modeland RJ-45 for SHDSL from left to right.
Rear Panel with the AC Type
Rear Panel with the DC Type
Connector Description
Power Power switch. Press 1 to turn on and press 0 for off.
100~240V AC Power socket. It has power adapting function from 90~240VAC.
36~72VDC Power socket . It has power adapting function from 36~ 72VDC.
Console RJ-45 for system configuration and maintenance.
Data PortDB25 interface is V.35 in the V.35 model or may be V.35, X.21,RS-530 or RS-449 in the SERIAL model
G.SHDSL RJ-45 or RJ-11 for G.SHDSL connection
8/2/2019 Shdtu03 Et100 Man
14/48
Chapter 2. Hardware Installation
2-4
IIIIII.. HHaarrddwwaarree IInnssttaallllaattiioonnNote: To avoid possible damage to the SHDTU03, do not turn on the product before
hardware installation.
1. Plug the power cord in the power socket.
2. Plug the console port in console if you want to configure the NTU with VT100
program on NB or PC.
3. Plug in the V.35 adaptor cable in the V.35 model or
may be V.35, X.21, RS-530 or RS-449 adaptor cables in the SERIAL model.
4. Plug in the SHDSL cable
5. Power on
! Warning! High voltage. Do not open
8/2/2019 Shdtu03 Et100 Man
15/48
Chapter 3. What is Auto Configuration
3-1
Some of the embedded functions do not have separate commands to setup.
Some functions are auto sensing depending on the configuration and tailor
themselves automatically. Some functions are always enabled.
I. Wetting Current
Wetting current, also known as loop sealing current, is a low-level DC current
applied to a loop for the specific purpose of maintaining cable splice integrity by
preventing the build-up of oxidation. The enable applies a relative 42 2 V DC
voltage to the cables and allows 2~3 mA of current to flow at all times. As with all
STU-C type devices, they have the ability to source wetting current. The SHDTU03
will automatically enable wetting current as STU-C type. As STU-R type, it will always
terminate the wetting current.
8/2/2019 Shdtu03 Et100 Man
16/48
Chapter 3. What is Auto Configuration
3-2
This page is left in blank intentionally
.
8/2/2019 Shdtu03 Et100 Man
17/48
Chapter 4. Configure via Keypad and LCD
4-1
I. Purpose
This chapter provides information about configuration your SHDSLNTU via the front panel LCD display and keypads.
Note: After you have completed all necessary settings for your SHDSLNTU, make sure to write the new configuration to NVRAM by writecommand and reboot the system for the of new configuration to take effect.
II. How to use key padsThe SHDTU03 is designed for user-friendly configuration with keypads
and LCD display without using PC or NB with VT100 terminal.
Key Pad Description
ESC Return to previous configuration menu.
Enter Skip to next configuration menu or configure the item.
L Select other parameter in the same level menu.
R Select other parameter in the same level menu.
8/2/2019 Shdtu03 Et100 Man
18/48
Chapter 4. Configure via Keypad and LCD
4-2
III. Menu TreeAfter turning on the SHDTU03, the LCD will prompt SHDSL NTU.
Press Enterto enter. There are five main commands.For more detail, refer to each title.
SHDSL NTU=(ETHERNET)=
SHOWSTATUS
SHOWSTATISTICS
STATUSTYPE
STATUSSHDSL
STATUSCode Version
SYSTEMSETUP
WRITECONFIGURATION
STATISTICSCURRENT 15MIN
STATISTICSCURRENT 24HOUR
STATISTICSPREVIOUS 15MIN
STATISTICSPREVIOUS 24HR
STATISTICSCLEAR ALL
SETUPTYPE
SETUPSHDSL
SETUPREMOTE CONFIG
*SAVE & REBOOT*YES
*SAVE & REBOOT*NO
more refers to next picture
more refers to next picture
more refers to next picture
more refers to next picture
more refers to next picture
more refers to next picture
more refers to next picture
more refers to next picture
more refers to next picture
more refers to next picture
more refers to next picture
SETUPDEFAULT
more refers to next picture
8/2/2019 Shdtu03 Et100 Man
19/48
Chapter 4. Configure via Keypad and LCD
4-3
Menu tree for SHOW STATUSYou can check three kinds of status via LCD display: TYPE, MODE SHDSL
and SERIAL.
SHDSL NTU=(ETHERNET)=
SHOWSTATUS
SHOWSTATISTICS
STATUSTYPE
* TYPE *********
* ANNEX **
STATUSSHDSL
* LINE RATE ****** Kbps
STATUSCode Version
KERNEL FPGA*.** *.**
* TX POWER ***.** dBm
* ATTENUATION ***.** dB
* SNR MARGIN *
**.** dB
SYSTEMSETUP
WRITE
CONFIGURATION
more refers to next picture
more refers to next picture
more refers to next picture
8/2/2019 Shdtu03 Et100 Man
20/48
Chapter 4. Configure via Keypad and LCD
4-4
Menu tree for SHOW STATISTICThe SHDTU03 can display for current 15 minutes and current 24 hours.The menu tree is as follows.
SHDSL NTU=(ETHERNET)=
SHOWSTATUS
SHOWSTATISTICS
SYSTEMSETUP
WRITE
CONFIGURATION
STATISTICSCURRENT 15MIN
* SHDSL ES *****
* SHDSL SES *****
* SHDSL UAS *****
* SHDSL LOSW *
****
STATISTICS
CURRENT 24HOUR
* SHDSL ES *
****
* SHDSL SES *****
* SHDSL UAS *****
* SHDSL LOSW *****
STATISTICSPREVIOUS 15MIN
QUARTER1
* SHDSL ES *****
* SHDSL SES *****
* SHDSL UAS *****
* SHDSL LOSW *****
QUARTER96
STATISTICSPREVIOUS 24HR
DAY1
* SHDSL ES *****
* SHDSL SES *
****
* SHDSL UAS *
****
* SHDSL LOSW *****
DAY7
STATISTICSCLEAR ALL
* CLEAR *YES
* CLEAR *N0
more refers to next picture
more refers to next picture
more refers to previous picture
8/2/2019 Shdtu03 Et100 Man
21/48
Chapter 4. Configure via Keypad and LCD
4-5
Menu tree for SETUP TYPE and SETUP SHDSLThe menu tree is as follows.
SHDSL NTU
=(ETHERNET)=
SYSTEM
SETUP
SETUP
TYPE
* SHDSL TYPE *
STU-C INTCLK
* SHDSL TYPE *
STU-C EXTCLK
* SHDSL TYPE *
STU-R
SETUP
ANNEX
SETUP
SHDSL
* SHDSL ANNEX *
ANNEX B
* SHDSL ANNEX *
ANNEX A
SETUP
SETUP MARGIN
* SHDSL MARGIN *
0
* SHDSL MARGIN *
10
* SHDSL MARGIN *
DISABLE
SETUP
PSD
* SHDSL PSD *
R1_ASYM
* SHDSL PSD *
R2_ASYM
* SHDSL PSD *
SYM_ENABLE
* SHDSL PSD *ASYM_DISABLE
SETUP
PWR BACKOFF
*PWR BACKOFF*
ON
*PWR BACKOFF*
OFF
SETUP
REMOTE CONFIG
more refers to next picture
8/2/2019 Shdtu03 Et100 Man
22/48
Chapter 4. Configure via Keypad and LCD
4-6
SETUPREMOTE CONFIG
REMOTE CONFIGENABLE
REMOTE CONFIGDISABLE
SHDSL NTU=(ETHERNET)=
SYSTEMSETUP
Menu tree for SETUP SERIALYou can configure serial interface in this menu.
Menu tree for SAVE CONFIGURATIONAfter configuration, the new parameters have to be saved in NVRAM by
following these steps. Choose WRITE CONFIGURATION by using L or Rkey and press Enter. Choose SAVE & REBOOT YES and then pressEnter.
WRITE
CONFIGURATION
*SAVE & REBOOT*
YES
*SAVE & REBOOT*NO
SHDSL NTU
=(ETHERNET)=
Congratulation! You are done. The configuration is complete.
8/2/2019 Shdtu03 Et100 Man
23/48
Chapter 5. Configure via Console Port
5-1
This chapter provides information about configuring the SHDTU03 via theconsole port with VT100 terminal.
Note: After you have completed all necessary settings for your SHDSLNTU, make sure to write the new configuration to NVRAM by writecommand and reboot the system for the of new configuration take effect.
II.. LLooggiinn PPrroocceedduurree
Check the connectivity of the RS-232 cable from your computer to theconsole port of SHDTU03. Start your terminal access program with VT100terminal emulation. Configure the serial link with baudrate of 9600, 8 databits, no parity check, 1 stop bit, and no flow-control, and press the SPACEkey until the login screen appears. When you see the login screen, you canlogon to the SHDTU03.
User : admin
Password: *****
Note: If you have not set any user profile for the SHDSL NTU, enter thefactory default user admin. When the system prompts you for a password,type admin to enter SHDSL NTU.
Us e r : a d mi nP a s s wo r d : * * * * *
8/2/2019 Shdtu03 Et100 Man
24/48
Chapter 5. Configure via Console Port
5-2
After you type the password, the SMT displays the main menu.
II. Window StructureFrom top to bottom, the window will be divided into four parts:
1. Product name2. Menu field: Menu tree is prompted on this field. >> symbol indicates the
cursor place.3. Configuring field: You will configure the parameters in this field.
< parameters > indicates the parameters you can choose and < more>indicates that there have submenu in the title.
4. Operation command for help
S H D S L N T U
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -> > s e t u p Co n f i g u r e s y s t e m
s t a t u s S h o w r u n n i n g s y s t e m s t a t u ss h o w V i e w s y s t e m c o n f i g u r a t i o nwr i t e Up d a t e f l a s h c o n f i g u r a t i o nr e b o o t Re s e t a n d b o o t s y s t e mu p g r a d e S o f t wa r e u p g r a d ee x i t Qu i t s y s t e m
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Co mma n d : s e t u p < mo r e . . . >M e s s a g e :
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -< I / K > Mo v e u p / d o wn , < L / J > Se l e c t / Un s e l e c t , < U/ O> Mo v e t o p / b o t t o m, < ^ Q> He l p
8/2/2019 Shdtu03 Et100 Man
25/48
Chapter 5. Configure via Console Port
5-3
III. System Management Terminal
(SMT)Menu Commands
Before changing the configuration, familiarize yourself with the operationslist in the following table. The operation list will be shown on the window.
Keystroke Description[UP] or I Move to above field in the same level menu.
[DOWN] or K Move to below field in the same lever menu.
[LEFT] or J Move back to previous menu.
[RIGHT] or L Move forward to submenu.
[ENTER] Move forward to submenu.
[TAB] To choose another parameters.
Ctrl + C To quit the configuring item.
Ctrl + Q For help
8/2/2019 Shdtu03 Et100 Man
26/48
Chapter 5. Configure via Console Port
5-4
Navigating the SMT interfaceUse the SMT (System Management Terminal) interface to configure the
NTU. The following figure is an overview of the menu tree.
User Name
& Passwordsetup
status
show
write
reboot
upgrade
exit
type
shdsl
rmtcfg
default
annex
margin
psd
pwr_backoff
enable
disable
shdsl
statistics
clear
system
script
kernel
FPGA
8/2/2019 Shdtu03 Et100 Man
27/48
Chapter 5. Configure via Console Port
5-5
IV. Main Menu Summary
The main menu is prompt as follows.
Menu Title Function
SetupUse this menu to setup SHDSL type, SHDSL parameters and
E1 parameters or restore factory default setting.
StatusUse this menu to show SHDSL status, E1 status and statistics
or clear the statistics
ShowUse this menu to show general information, all configurations
and all configurations in command script.
Write Use this menu to save your configuration.
Reboot Use this menu to reset and reboot the system
Upgrade Use this menu to upgrade kernel and FPGA.
Exit Use this menu to exit STM
8/2/2019 Shdtu03 Et100 Man
28/48
Chapter 5. Configure via Console Port
5-6
V. Configure the SHDSL NTU
This section provides information about configuring the SHDSL NTU.Follow the procedures:
In main menu, select setup and press [ENTER] or [RIGHT].
--------------------------------------------------
>>setup Configure system
status Show running system status
show View system configuration
write Update flash configuration
reboot Reset and boot the system
upgrade Software upgrade
exit Quick system
--------------------------------------------------
The screen will prompt as follows
-------------------------------------------
>>type Configure shdsl type
shdsl Configure shdsl parameters
rmtcfg enable/disable remote configuration
default Restore factory default setting
--------------------------------------------
8/2/2019 Shdtu03 Et100 Man
29/48
Chapter 5. Configure via Console Port
5-7
Configure SHDSL type
This section will introduce the configuring of SHDSL type: STU-R,STU-C-INTCLK. The default operation type is STU-R.Select type and press [ENTER] or [RIGHT] to setup SHDSL type. Press[TAB] to select the operating type and press enter to finish setting.
---------------------------------------------------
>> typeConfigure shdsl type
shdslConfigure shdsl parameters
rmtcfgenable/disable remote configuration
defaultRestore factory default setting
---------------------------------------------------
Command: setup type
Message: Please input the following information.
SHDSL operation type (TAB Select) : STU-C-INTCLK
--------------------------------------------------------
INTCLK: The device will generate the appropriate clock speed defined bythe speed setting of the interface.
Most applications use Internal Clock.
8/2/2019 Shdtu03 Et100 Man
30/48
Chapter 5. Configure via Console Port
5-8
Configure SHDSL parametersThis section provide the setup for SHDSL parameters: Annex type,
margin, psd, wetting current, power backoff and framer.Select SHDSL and press [ENTER] or [RIGHT].
--------------------------------------------------
type Configure shdsl type
>> shdsl Configure shdsl parameters
rmtcfg enable/disable remote configuration
default Restore factory default setting
For setting the SHDSL Annex type, move the cursor to annex and press[ENTER]. Select the annex type by using [TAB] key.
--------------------------------------------------
>> annex Configure shdsl annex
margin Configure shdsl margin
psd Configure shdsl psd
pwr_backoff Configure power backoff
Command: setup shdsl annex
Message: Please input the following information.
Annex Type (TAB Select) :Annex_B
--------------------------------------------------------
For setting SHDSL Margin, move the cursor to margin and press [ENTER].Select the startup margin via [TAB] key and key in the Next margin.
---------------------------------------------------
annex Configure shdsl annex
>> margin Configure shdsl margin
psd Configure shdsl psd
pwr_backoff Configure power backoff
8/2/2019 Shdtu03 Et100 Man
31/48
Chapter 5. Configure via Console Port
5-9
---------------------------------------------------
Command: setup shdsl margin
Message: Please input the following information.
Set Startup Margin (TAB Select): Disable
--------------------------------------------------------
For configuring SHDSL PSD, move the cursor to psd and press [ENTER].Select the parameter via [TAB] key.
--------------------------------------------------------------------
annex Configure shdsl annex
margin Configure shdsl margin
>> psd Configure shdsl psd
pwr_backoff Configure power backoff
--------------------------------------------------
Command: setup shdsl psd
Message: Please input the following information.
SHDSL PSD (TAB Select) : r2_asym
--------------------------------------------------------
The SHDSL PSD will enable the transceiver to use an asymmetric powerspectral density, as specified in the G.991.2 standard.
Possible values for PSD are:
r1_asym: 786kbps for Annex A, 2312kbps for Annex Br2_asym: 1552kbps for Annex A, 2056kbps for Annex Bsym_enable: Symmetric and Asymmetric enable.asym_disable: Symmetric enable but asymmetric disable.
8/2/2019 Shdtu03 Et100 Man
32/48
Chapter 5. Configure via Console Port
5-10
For configuring power backoff, move the cursor to pwr_backoff and press[ENTER]. Select enable or disable via [TAB] key.
-----------------------------------------------------annex Configure shdsl annex
margin Configure shdsl margin
psd Configure shdsl psd
>> pwr_backoff Configure power backoff
rate*64 Configure the data rate
-------------------------------------------------------
Command: setup shdsl pwr_backoff
Message: Please input the following information.
SHDSL Power Backoff (TAB Select) : enable
------------------------------------------------------
The power backoff of SHDSL is a transmit power negotiationmechanism applied between STU-C and STU-R to limit the powertransmitted on the SHDSL line to the minimum necessary for a clear signalto be received at the STU-C.
For configuring shdsl data rate, move the cursor to rate*64 and press[ENTER]. Select a rate 1 (64kbps) to 36 (2304kbps).
-----------------------------------------------------
annex Configure shdsl annex
margin Configure shdsl margin
psd Configure shdsl psd
pwr_backoff Configure power backoff
>> rate*64 Configure the data rate-------------------------------------------------------
Command: setup shdsl rate*64
Message: Please input the following information.
SHDSL SERIAL n*64 (ENTER for default) :
------------------------------------------------------
8/2/2019 Shdtu03 Et100 Man
33/48
Chapter 5. Configure via Console Port
5-11
Configure Remote parameters
When the SHDSL modem is configured as STU-R, the modem may beremotely managed from another STU-C modem or from a line card in theSHDSL RACK. For configure the remote management function, move thecursor to rmtcfg and press [ENTER]. Select enable or disable via [TAB] key.
-------------------------------------------------------
type Configure shdsl type
shdsl Configure shdsl parameters
>> rmtcfg enable/disable remote configurationdefault Restore factory default setting
-------------------------------------------------------
Restore factory default
If you want to restore factory default setting in setup, select default
and press [ENTER] or [RIGHT].
----------------------------------------------------------
type Configure shdsl type
shdsl Configure shdsl parameters
rmtcfg enable/disable remote management
>> default Restore factory default setting
------------------------------------------------------------
Command: setup defaultMessage: Please input the following information.
Are you sure? (y/n): y
------------------------------------------------------------
If you enter y the setup field will be automatically configured to factorydefault setting.
8/2/2019 Shdtu03 Et100 Man
34/48
Chapter 5. Configure via Console Port
5-12
VI. Write the Setup Parameter
After configuration, write the new configured parameters into NVRAMand reboot the SHDSL NTU to work with new parameters. Follow theprocedure;
Step 1: In main menu, move the cursor to write and press [ENTER].
--------------------------------------------------------------
setup Configure system
status Show running system statusshow View system configuration
>> write Update flash configuration
reboot Reset and boot the system
upgrade Software upgrade
exit Quick system
--------------------------------------------------------------
Step 2: Type y to write the new parameters
---------------------------------------------------------------
Command: write
Message: Please input the following information.
Are you sure? (y/n): y
---------------------------------------------------------
8/2/2019 Shdtu03 Et100 Man
35/48
Chapter 5. Configure via Console Port
5-13
VII. Reboot the SHDSL NTU
For the SHDSL NTU to work with new parameters, you must reboot itafter writing the parameters into NVRAM. Follow the procedure;
Step 1: In main menu, move the cursor to reboot and press [ENTER].
--------------------------------------------------------------
setup Configure system
status Show running system status
show View system configuration
write Update flash configuration
>> reboot Reset and boot the system
upgrade Software upgrade
exit Quick system
--------------------------------------------------------------
Step 2: Type y to reboot the SHDSL NTU.
---------------------------------------------------------------
Command: reboot
Message: Please input the following information.
Do you want to reboot? (y/n): y
---------------------------------------------------------
8/2/2019 Shdtu03 Et100 Man
36/48
Chapter 5. Configure via Console Port
5-14
VIII. View the System Status
You can use the status command to view the status of SHDSL, as well asstatistic and clear the statistic log. Select status and press [ENTER].
------------------------------------------------------------
setup Configure system
>> status Show running system status
show View system configuration
write Update flash configuration
reboot Reset and boot the system
upgrade Software upgrade
exit Quick system
------------------------------------------------------------
Select SHDSL command to show the status of SHDSL.
------------------------------------------------------------
>> shdsl Show shdsl status
statistic Show statisticclear Clear statistic
------------------------------------------------------------
Select statistic command to show the statistic information in 15 minutes
or 24 hour via [TAB] to choose.
------------------------------------------------------------
shdsl Show shdsl status
>> statistic Show statistic
clear Clear statistic
Command: status statistic
Message: Please input the following information.
SHDSL Statistic (TAB Select): 15m
---------------------------------------------------------------------
8/2/2019 Shdtu03 Et100 Man
37/48
Chapter 5. Configure via Console Port
5-15
To clear the statistic log file, select clear and press [ENTER].
------------------------------------------------------------
shdsl Show shdsl statusstatistic Show statistic
>> clear Clear statistic
------------------------------------------------------------
8/2/2019 Shdtu03 Et100 Man
38/48
Chapter 5. Configure via Console Port
5-16
IX. View the System Configuration
You can use the status command to view the system configuration. Selectshow and press [ENTER] or [RIGHT].
------------------------------------------------------------
setup Configure system
status Show running system status
>> show View system configuration
write Update flash configuration
reboot Reset and boot the system
upgrade Software upgrade
exit Quick system
------------------------------------------------------------
To show system information, select system and press [ENTER] or [RIGHT].The screen will prompt the system information.
------------------------------------------------------------
>> system Show general informationscript Show all configuration in command script
------------------------------------------------------------
To show the system configuration, select script and press [ENTER] or[RIGHT]. The screen will prompt the configuration in script type.
------------------------------------------------------------
system Show general information
>> script Show all configuration in command script
------------------------------------------------------------
8/2/2019 Shdtu03 Et100 Man
39/48
Chapter 5. Configure via Console Port
5-17
X. Upgrade the SHDSL NTU
This section will introduce how to upgrade the kernel and FPGA of theSHDSL NTU. Select upgrade in main menu and press [ENTER] or [RIGHT].
------------------------------------------------------------
setup Configure system
status Show running system status
show View system configuration
write Update flash configuration
reboot Reset and boot the system
>> upgrade Software upgrade
exit Quick system
------------------------------------------------------------
Before upgrading the NTU you must have the main software or FPGA
code in your computer.
If you want to upgrade the kernel:
1. Select kernel and press [ENTER] or [RIGHT].
-----------------------------------------------------------
>> kernel Upgrade main software
FPGA Upgrade FPGA code
-----------------------------------------------------------
2. Confirm the process via pressing y-----------------------------------------------------------
Command: upgrade kernel
Message: Please input the following information.
Are you sure (y/n)?: (Note: this will erase flash)y
---------------------------------------------------------------------
3. After entering y, the SMT will show
8/2/2019 Shdtu03 Et100 Man
40/48
Chapter 5. Configure via Console Port
5-18
------------------------------------------------------------
Utility running window...
Starting XModem download...CCC
------------------------------------------------------------
4. Click Send file in terminal access program, hyper terminal, to send thefile.
5. Select the source file in window and press OK.
6. After upgrading the product, press y to write in flash.
If you want to upgrade the FPGA code:
1. Select FPGA and press [ENTER] or [RIGHT].-----------------------------------------------------------
kernel Upgrade main software
>> FPGA Upgrade FPGA code
------------------------------------------------------------
Command: upgrade FPGA Message: Please input the following information.
Are you sure (y/n)?: (Note: this will erase flash)y
------------------------------------------------------------
2. After entering y, the SMT will show
------------------------------------------------------------
Utility running window...Starting XModem download...CCC
---------------------------------------------------------
3. Click Send file in terminal access program, hyper terminal, to send thefile.
4. Select the source file in window and press OK.
5. After upgrading the product, press y to write in flash.
8/2/2019 Shdtu03 Et100 Man
41/48
Chapter 5. Configure via Console Port
5-19
XI. Exit SMT
For exiting SMT without saving any configuration, you can use the exitcommand to exit the SMT. Select exit and press [ENTER] or [RIGHT].
------------------------------------------------------------
setup Configure system
status Show running system status
show View system configuration
write Update flash configuration
reboot Reset and boot the system
upgrade Software upgrade
>> exit Quick system
------------------------------------------------------------
------------------------------------------------------------
Command: exit
Message: Please input the following information.
Do you want to disconnect? (y/n) : y
------------------------------------------------------------
After press [ENTER], the SMT will be disconnected.
8/2/2019 Shdtu03 Et100 Man
42/48
8/2/2019 Shdtu03 Et100 Man
43/48
APPENDIX
A-1
Appendix IAMI Alternate mark inversion
B8ZS Bipolar 8 zero substitution
CAS Also known as timeslot 16 multiframing, requires a multiframe
alignment signal to represent for frame sync.
CRC4 Cyclic redundancy check 4 bit
E BIT GEN Remote End Block Error Bit generation
EOC Embedded operations channel
ES Number of Error second (Errors/Second)
ESF Extended super frame
FAS Frame alignment signal
LINE BUILD OUTS Cable used between NTU and Router or PABX
LOSW Loss of synchronization word
PSD Power spectral density
RAI Remote alarm indication
R1 ASYM Symmetric speed, 784kbps for Annex A or 2312kbps for
Annex B
R2 ASYM Symmetric speed, 1552kbps for Annex A or 2056kbps for
Annex B
SES(Severe Error
Second)
Number of SES (more than 832 CRC errors / second.
Approximately equivalent to a bit error rate of 1 x 10-3.
SF Super Frame
SNR MARGIN Signal to noise ration margin
SYNC Synchronization
TX POWER Transmission power
UAS Number of Unavailable second (more than10 seconds.)
Appendix II
8/2/2019 Shdtu03 Et100 Man
44/48
APPENDIX
A-2
Connector ArchitectureConsole Connector (RJ-45)
The Console Port interface is a 8 position Modular Jack.The table below displays the pin out assignments.
Pin Number Description Figure
1No connection
2No connection
3No connection
4 GND
5RC
6TD
7No connection
8No connection
1 8
1 8
Top View
Fro nt V iew
Ethernet Connector (RJ-45)The Ethernet Port interface is a 8 position Modular Jack.
The table below displays the pin out assignments.
Pin Number Description Figure
1MDI TX+
2MDI TX-
3MDI RX+
4No connection
5No connection
6MDI RX-
7No connection
8No connection
1 8
1 8
Top View
Fro nt V iew
8/2/2019 Shdtu03 Et100 Man
45/48
APPENDIX
A-3
SHDSL Interface Pin Assignments (RJ-45)
The SHDSL interface is standard eight-pin modular jack.
The table below displays the pin out assignments.
Pin Number Description Figure
1No connection
2No connection
3No connection
4
ANALOG
Input/Output
5ANALOG
Input/Output
6No connection
7No connection
8No connection
1 8
1 8
Top View
Fr ont V iew
8/2/2019 Shdtu03 Et100 Man
46/48
APPENDIX
A-4
Appendix III
Cable Connection
DB9 vs. RJ45 Cable (Console)
DCD1
RXD2
TXD3
DTR4
GND5
DSR6
RTS7
CTS8
DSR1
DCD2
DTR3
GND4
RXD5
TXD6
CTS7
RTS8
NC9
DB9 (Female) RJ-45
The table below displays Serial Interface Pin Assignments for the DCE Mode.
8/2/2019 Shdtu03 Et100 Man
47/48
8/2/2019 Shdtu03 Et100 Man
48/48
Transmission Units