9
R E N E W A B L E S R E N E W A B L E S NOTES: SEE SOLECTRIA RENEWABLES SGI 225, 250, 266, 300, 500 1. AND 500PE INSTALLATION AND OPERATION MANUAL FOR FURTHER INSTALLATION REQUIREMENTS. CUSTOMER INTERFACE DRAWING SHEETS INCLUDE: 2. FRONT ISOMETRIC 1. FRONT 2. REAR 3. RIGHT 4. LEFT 5. TOP 6. BOTTOM 7. AS SHIPPED ISOMETRIC 8. RECOMMENDED RIGGING AND LIFTING METHODS 9. REVISIONS REV EC# DESCRIPTION DRAWN CHECKED DATE A 1052 INITIAL RELEASE J. KADOKO C. THOMPSEN 03/26/2013 B 1059 ENCLOSURE LIFT EYES CHANGED TO LIFT TABS NEW REVISION OF AIR INTAKE SHROUDS WITH ANGLED TOP NEW AC BREAKER AND DC DISCONNECT ROTARY HANDLES ADDED AC/DC CONDUIT ENTRY COLLAR TO MODEL ADDED RIGGING AND LIFTING SHEET C. THOMPSEN J. KADOKO 10/17/2013 C 1185 REVISION TO PALLET C. THOMPSEN M. KELLY 4/14/2014 APPROXIMATE PRODUCT MASS (LBS) SGI 225 SGI 250, 266, 300 SGI 500, 500PE INSTALLED MASS: 5170 5650 6980 SHIPPING MASS: 5380 5860 7190 WWW.SOLECTRIA.COM SIZE: B REV: SCALE: 1:15 SHEET 1 OF 9 ALL DIMENSIONS ARE IN INCHES DO NOT SCALE PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE ISO 04-04-26 REV. A DOCUMENT: DOCR-070257 C VIEW: PRODUCT: SGI 225-500PE CUSTOMER INTERFACE DRAWING FRONT ISOMETRIC WWW.SOLECTRIA.COM SIZE: B REV: SCALE: 1:15 SHEET 1 OF 9 ALL DIMENSIONS ARE IN INCHES DO NOT SCALE PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE ISO 04-04-26 REV. A DOCUMENT: DOCR-070257 C VIEW: PRODUCT: SGI 225-500PE CUSTOMER INTERFACE DRAWING FRONT ISOMETRIC

SGI 225-500PE - d1819pwkf4ncw.cloudfront.net · r e n e w a b l e s notes: 1. see solectria renewables sgi 225, 250, 266, 300, 500 and 500pe installation and operation manual for

Embed Size (px)

Citation preview

R E N E W A B L E SR E N E W A B L E S

NOTES:SEE SOLECTRIA RENEWABLES SGI 225, 250, 266, 300, 500 1.AND 500PE INSTALLATION AND OPERATION MANUAL FOR FURTHER INSTALLATION REQUIREMENTS.CUSTOMER INTERFACE DRAWING SHEETS INCLUDE:2.

FRONT ISOMETRIC1.FRONT2.REAR3.RIGHT4.LEFT5.TOP6.BOTTOM7.AS SHIPPED ISOMETRIC8.RECOMMENDED RIGGING AND LIFTING METHODS9.

REVISIONSREV EC# DESCRIPTION DRAWN CHECKED DATEA 1052 INITIAL RELEASE• J. KADOKO C. THOMPSEN 03/26/2013

B 1059

ENCLOSURE LIFT EYES CHANGED TO LIFT TABS•NEW REVISION OF AIR INTAKE SHROUDS WITH •ANGLED TOPNEW AC BREAKER AND DC DISCONNECT •ROTARY HANDLESADDED AC/DC CONDUIT ENTRY COLLAR TO •MODELADDED RIGGING AND LIFTING SHEET•

C. THOMPSEN J. KADOKO 10/17/2013

C 1185 REVISION TO PALLET• C. THOMPSEN M. KELLY 4/14/2014

APPROXIMATE PRODUCT MASS (LBS)SGI 225 SGI 250, 266, 300 SGI 500, 500PE

INSTALLED MASS: 5170 5650 6980

SHIPPING MASS: 5380 5860 7190

WWW.SOLECTRIA.COM

SIZE: BREV:

SCALE: 1:15 SHEET 1 OF 9

ALL DIMENSIONS AREIN INCHES DO NOT SCALE

PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO 04-04-26 REV. A

DOCUMENT: DOCR-070257 C

VIEW:

PRODUCT: SGI 225-500PE

CUSTOMER INTERFACE DRAWING

FRONT ISOMETRIC

WWW.SOLECTRIA.COM

SIZE: BREV:

SCALE: 1:15 SHEET 1 OF 9

ALL DIMENSIONS AREIN INCHES DO NOT SCALE

PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO 04-04-26 REV. A

DOCUMENT: DOCR-070257 C

VIEW:

PRODUCT: SGI 225-500PE

CUSTOMER INTERFACE DRAWING

FRONT ISOMETRIC

R E N E W A B L E S

4

109

4

79 82

60 12

MINIMUM DISTANCE THAT MUST BE CLEAR ABOVE THE INVERTER

FOR VENTILATION

6MINIMUM DISTANCE THAT MUST BE CLEAR TO EACH SIDE OF THE

INVERTER FOR VENTILATION

1.5

30(COG)

70(COG)

6 UNITLIFTINGLOCATIONS

NOTES:DIMENSIONS INDICATED BY (COG) SHOW APPROXIMATE 1.LOCATION OF THE INVERTER CENTER OF GRAVITY.

WWW.SOLECTRIA.COM

SIZE: BREV:

SCALE: 1:12 SHEET 2 OF 9

ALL DIMENSIONS AREIN INCHES DO NOT SCALE

PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO 04-04-26 REV. A

DOCUMENT: DOCR-070257 C

VIEW:

PRODUCT:

FRONT

SGI 225-500PE

CUSTOMER INTERFACE DRAWING

R E N E W A B L E S

7

12 49

13

33

18.31

11.65

ALTERNATE ACCONDUIT ENTRYLOCATION

EXHAUST AIR VENTS

WWW.SOLECTRIA.COM

SIZE: BREV:

SCALE: 1:12 SHEET 3 OF 9

ALL DIMENSIONS AREIN INCHES DO NOT SCALE

PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO 04-04-26 REV. A

DOCUMENT: DOCR-070257 C

VIEW:

PRODUCT:

REAR

SGI 225-500PE

CUSTOMER INTERFACE DRAWING

R E N E W A B L E S

5

29.6

WITHOUT AIR FILTER OPTION

BOTTOM SHROUD NOTINSTALLED DEPENDING ON

POWER LEVEL. SEE TABLE.

STANDARD AIR INTAKE SHROUD

10

WITH AIR FILTER OPTION

AIR FILTER SHROUD

BOTTOM SHROUD NOTINSTALLED DEPENDING ON

POWER LEVEL. SEE TABLE.

NOTES:NUMBER OF AIR INTAKE SHROUDS OR AIR FILTER SHROUDS DEPENDS ON INVERTER POWER LEVEL. 1.REFER TO TABLE.

SGI 225, 250, 266, 300 SGI 500, 500PE

NUMBER OF SHROUDS 2 3

WWW.SOLECTRIA.COM

SIZE: BREV:

SCALE: 1:12 SHEET 4 OF 9

ALL DIMENSIONS AREIN INCHES DO NOT SCALE

PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO 04-04-26 REV. A

DOCUMENT: DOCR-070257 C

VIEW:

PRODUCT:

RIGHT

SGI 225-500PE

CUSTOMER INTERFACE DRAWING

R E N E W A B L E S 13

36

0.5

4.5

18 21

34 30(COG)

16(COG)

ALTERNATE DCCONDUIT ENTRY

LOCATIONS

NOTES:DIMENSIONS INDICATED BY (COG) SHOW APPROXIMATE 1.LOCATION OF THE INVERTER CENTER OF GRAVITY.

WWW.SOLECTRIA.COM

SIZE: BREV:

SCALE: 1:12 SHEET 5 OF 9

ALL DIMENSIONS AREIN INCHES DO NOT SCALE

PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO 04-04-26 REV. A

DOCUMENT: DOCR-070257 C

VIEW:

PRODUCT:

LEFT

SGI 225-500PE

CUSTOMER INTERFACE DRAWING

R E N E W A B L E SR E N E W A B L E S

18MINIMUM DISTANCE THATMUST BE CLEAR BEHIND

THE INVERTER FOR VENTILATIONAND MAINTENANCE ACCESS

43.5 41.5 36

6X 0.56

60.0 45.0

25 29

NOTES:DOORS CAN SWING MORE THAN 90°.1.

WWW.SOLECTRIA.COM

SIZE: BREV:

SCALE: 1:12 SHEET 6 OF 9

ALL DIMENSIONS AREIN INCHES DO NOT SCALE

PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO 04-04-26 REV. A

DOCUMENT: DOCR-070257 C

VIEW:

PRODUCT:

TOP

SGI 225-500PE

CUSTOMER INTERFACE DRAWING

WWW.SOLECTRIA.COM

SIZE: BREV:

SCALE: 1:12 SHEET 6 OF 9

ALL DIMENSIONS AREIN INCHES DO NOT SCALE

PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO 04-04-26 REV. A

DOCUMENT: DOCR-070257 C

VIEW:

PRODUCT:

TOP

SGI 225-500PE

CUSTOMER INTERFACE DRAWING

R E N E W A B L E S

28.0KEEP CONDUIT AT LEAST

1 INCH FROM EDGES OF OPENING

23.0

25.0

4.0 6.8

4

0.13 DRAIN HOLES DC AND AC

CONDUIT FLOORENTRY LOCATION

WWW.SOLECTRIA.COM

SIZE: BREV:

SCALE: 1:12 SHEET 7 OF 9

ALL DIMENSIONS AREIN INCHES DO NOT SCALE

PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO 04-04-26 REV. A

DOCUMENT: DOCR-070257 C

VIEW:

PRODUCT:

BOTTOM

SGI 225-500PE

CUSTOMER INTERFACE DRAWING

R E N E W A B L E S

120

45RECOMMENDED FORK LIFT

LOCATIONS

22

48

WITHOUT AIR FILTER OPTION

120

29

36

5.5

48

WITH AIR FILTER OPTION

NOTES:THE INVERTER IS SHIPPED ON AN OVERSIZED SHIPPING PALLET. IT IS RECOMMENDED TO KEEP THE INVERTER SECURED TO 1.THE PALLET AND MOVED AS CLOSE AS POSSIBLE TO THE FINAL LOCATION PRIOR TO REMOVING THE PALLET.

WWW.SOLECTRIA.COM

SIZE: BREV:

SCALE: 1:22 SHEET 8 OF 9

ALL DIMENSIONS AREIN INCHES DO NOT SCALE

PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO 04-04-26 REV. A

DOCUMENT: DOCR-070257 C

VIEW:

PRODUCT:

AS SHIPPED ISOMETRIC

SGI 225-500PE

CUSTOMER INTERFACE DRAWING

R E N E W A B L E S

15 FEETMINIMUM

RECOMMENDED FORKLIFT LOCATIONS ARE

INDICATED BY LABELS

45 56

RECOMMENDED FORKLIFT LOCATIONS ARE

INDICATED BY LABELS

NOTES:RECOMMENDED SINGLE POINT LIFTING METHOD SHOWN. SEE SOLECTRIA 1.RENEWABLES SGI 225, 250, 266, 300, 500 AND 500PE INSTALLATION AND OPERATION MANUAL FOR PREFERED LIFTING METHODS AND ADDITIONAL LIFTING AND INSTALLATION REQUIREMENTS.

WWW.SOLECTRIA.COM

SIZE: BREV:

SCALE: 1:32 SHEET 9 OF 9

ALL DIMENSIONS AREIN INCHES DO NOT SCALE

PLEASE NOTE: ALL INFORMATION CONTAINED WITHIN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO 04-04-26 REV. A

DOCUMENT: DOCR-070257 C

VIEW:

PRODUCT:

RECOMMENDED RIGGING AND LIFTING METHODS

SGI 225-500PE

CUSTOMER INTERFACE DRAWING