2
Note Caution Caution Caution Caution Caution Read through this manual before use. Read the manual and then operate all functions. For a right after-sales service, prepare a product certificate and keep it. Do not disassemble the machine at random. It may result in failure. When you disassemble it at your disposal, it may not work normally. If necessary, contact the customer center. Don not give the machine any impact or perform remodeling in any case. Otherwise, it may result in failure and malfunction. Do use the machine at a place where there is no water or moisture. It has no waterproof and dustproof function. So, any failure may be caused by short circuit, etc. Close all holes in the door after installation. Otherwise, outsiders may enter without permission through a slot for milk throwing or questions. Keep the machine away from strong inflammable materials like a gas lighter. Otherwise, it may result in failure and malfunction. Do not use the machine at any place where there is strong direct sunlight or high temperature. Otherwise, it may result in failure and malfunction. Do not install the machine at any place where it may contact directly with rain or snow. Otherwise, it may result in failure and malfunction. Do not give direct watering to the machine when cleaning. Otherwise, it may result in failure and malfunction. When exchanging batteries, replace all of them by new spares. If new batteries are used together with used ones, their life cannot be guaranteed and the machine may not work normally. Use genuine alkaline batteries only. If rechargeable batteries are used, the machine may not work normally. 1 Safety Notes 3 Name of the parts - 9V emergency power terminal : In case of battery discharge, you can open the door using a 9V battery. - Reset function : By pressing reset button through a hole with sharp pin, temporary program error can be solved. (Pin code dose not change with this action) - Card/Tag Input part : Contact the Card to the machine to open the door. - Open/Close button : One-touch button used to open or close the door indoors. - Manual operating device : Used to open the door manually (available for a fire or other emergences) - Fire detection sensor : A fire detection sensor to open the door automatically in case of a fire is built in. (60 ±5 ) - Dead bolt(keeper) : Indoor fastener of door lock - Auto lock internal sensor : When auto lock is set, the magnetic sensor to close the door lock automatically is built in. - Input button : Used to input the password, register and delete the Card. Outer Body Indoor Body Thank you for purchasing our product. You must be aware of this manual before use. - This manual includes the product certificate. It must include the name of installation agent, its contact point, and the date of installation. Otherwise you cannot receive a right after-sales service. - The performance and design of this product may be changed for the improvement of quality. SGDL TG11 • Set and change the password up to 3 to 19 digits • Register Card/Tag up to 50ea • Fire detection sensor • Auto locking function • 9V emergency power is supplied. • Alarm sound when forced to open in an abnormal manner • Burglar and malicious action alarm function Note for product images used in this manual are for illustrative purposes, and the shape and color of products may vary depending on the model. Prohibit Prohibit Prohibit Prohibit Prohibit DIGITAL DOOR LOCK 2 Components (Check that the purchased products include components as follows.) Supplementary Components (Card/Tag Applied Model) Seperately purchased components (Remote control Applied Model) Card/Tag Remote control : 2ea - Register the card/Tag only provided from the manufacturer - Rregistering and using Transportation card or Credit card can cause security problem, you may not receive A/S or compensation for any damages in case of that. Caution Rubber Magnet (For single door) Stopper (Stopper for door holding) AA Battery : 4ea (Alkaline) Installation Drawing User Manual Warning Sticker Outer Body : 1ea Indoor Body : 1ea Holder Clip Holder (seperately purchase) Card/Tag may be changeable in shape & color Supplementary Components, quantities may vary according to its access type. The shape of Remote control may change. Reset button 9V Emergency Power Terminal Password button Start/Ending button Card/Tag input part (Card/Tag Applied Model) Battery cover Input Button Manual Operating Device Open/Close button Dead Bolt (Keeper) Auto lock internal sensor Installation (Glass door lock without fixing plate) Installation Tips! 1. Sprinkling a little water over Glass door help you install easier. 2. Depending on door condition, having silicone coating around the doorlock can help prevent from slipping off. Registering: Press input button one time and then press any button of remote control. It informs you of successful registering with "ding dong dang" sound. (Register within 8 seconds) Deleting: Press input button one time and then press "5" button two times. Lastly press “”button to complete. Remote control can be registered up to 15ea Opening/Closing Door is closed or opened within 2~3 seconds after pressing the button. Frequency: FM447.275Mhz Battery: AAA Size X 2EA (CR2032 1EA) *Keep the door open while registering and checking password that it is normally registered. 1. Open the battery cover in the indoor body, and press Input button one time. ("Beep" sound will occur.) 2. Input the new password. (Up to 3 to 19 digits can be registered.) 3. Press “” button to complete the registration. (“ding-dong-dang" sound will occur to inform you of successful input.) 1. Open the battery cover in the indoor body, and press Input button one time. ("Beep" sound will occur.) 2. Contact each Card/Tag to be registered to the external input part to the machine. Up to 50 keys can be registered. 3. Press “” button to complete the registration. “Ding-dong-dang” for success. ("Beep" sound for failure.) 4 Using Remote Control (Applied model only) 5 Password Registering 8 Card/Tag Deleting (Card/Tag Applied Model) 7 Card/Tag Registering (Card/Tag Applied Model) 6 Password Changing - To go to the next stage, perform it before the lamp turns off (within 15 seconds). - Never fail to register and change the password with the door opened. - The password is set to “1234” at the factory. - After installation, necessarily change it before use. - Register the card/Tag only provided from the manufacturer. - Rregistering and using Transportation card or Credit card can cause security problem, you may not receive A/S or compensation for any damages in case of that. * Register the password with the same method as specified above. * When the new password is registered, the existing password is automatically deleted. 1. Open the battery cover in the indoor body, and press Input button one time. ("Beep" sound will occur.) 2. Two times press “0” button on the digit board in the outdoor body. 3. Press “” button to complete the deletion. When the Card/Tag is deleted, existing registered Card/Tag are completely deleted. Then, newly register Card/Tag to be used. Open/Close button How to change left-side door or right-side door. 1.Open battery cover. 2.Insert screwdriver through a hole. 3.Unscrew the fixed one. 4.Pull the front body outward to come off. 5.Turn it halt 180˚and fix it with the screw again. Alarm system is working

SGDL TG11 Safety Notes Components Name of the parts … Door Lock...Read through this manual before use. ... its contact point, ... Lot PT355, Jalan TPP5/1,Tmn Perindustrian Puchong,

  • Upload
    buidat

  • View
    215

  • Download
    2

Embed Size (px)

Citation preview

Page 1: SGDL TG11 Safety Notes Components Name of the parts … Door Lock...Read through this manual before use. ... its contact point, ... Lot PT355, Jalan TPP5/1,Tmn Perindustrian Puchong,

Note

Caution

Caution

Caution

Caution

Caution

Read through this manual before use.Read the manual and then operate all functions. For a right after-sales service, prepare a product certificate and keep it. Do not disassemble the machine at random. It may result in failure.When you disassemble it at your disposal, it may not work normally. If necessary, contact the customer center. Don not give the machine any impact or perform remodeling in any case.Otherwise, it may result in failure and malfunction.

Do use the machine at a place where there is no water or moisture.It has no waterproof and dustproof function. So, any failure may be caused by short circuit, etc.

Close all holes in the door after installation.Otherwise, outsiders may enter without permission through a slot for milk throwing or questions.

Keep the machine away from strong inflammable materials like a gas lighter.Otherwise, it may result in failure and malfunction.

Do not use the machine at any place where there is strong direct sunlight or high temperature.Otherwise, it may result in failure and malfunction. Do not install the machine at any place where it may contact directly with rain or snow.Otherwise, it may result in failure and malfunction. Do not give direct watering to the machine when cleaning.Otherwise, it may result in failure and malfunction.

When exchanging batteries, replace all of them by new spares. If new batteries are used together with used ones, their life cannot be guaranteed and the machine may not work normally. Use genuine alkaline batteries only. If rechargeable batteries are used, the machine may not work normally.

1 Safety Notes 3 Name of the parts

- 9V emergency power terminal : In case of battery discharge, you can open the door using a 9V battery.- Reset function : By pressing reset button through a hole with sharp pin, temporary program error can be solved. (Pin code dose not change with this action)- Card/Tag Input part : Contact the Card to the machine to open the door. - Open/Close button : One-touch button used to open or close the door indoors.- Manual operating device : Used to open the door manually (available for a fire or other emergences) - Fire detection sensor : A fire detection sensor to open the door automatically in case of a fire is built in. (60℃±5℃)- Dead bolt(keeper) : Indoor fastener of door lock - Auto lock internal sensor : When auto lock is set, the magnetic sensor to close the door lock automatically is built in.- Input button : Used to input the password, register and delete the Card.

▣ Outer Body ▣ Indoor Body

Thank you for purchasing our product. You must be aware of this manual before use. - This manual includes the product certificate. It must include the name of installation agent, its contact point, and the date of installation. Otherwise you cannot receive a right after-sales service.- The performance and design of this product may be changed for the improvement of quality.

SGDL TG11

• Set and change the password up to 3 to 19 digits • Register Card/Tag up to 50ea• Fire detection sensor • Auto locking function • 9V emergency power is supplied. • Alarm sound when forced to open in an abnormal manner• Burglar and malicious action alarm function

Note for product images used in this manual are for illustrative purposes, and the shape and color of products may vary depending on the model.

Prohibit

Prohibit

Prohibit

Prohibit

Prohibit

D I G I T A L D O O R L O C K

2 Components (Check that the purchased products include components as follows.)

▣ Supplementary Components (Card/Tag Applied Model)

▣ Seperately purchased components (Remote control Applied Model)

Card/Tag Remote control : 2ea

- Register the card/Tag only provided from the manufacturer- Rregistering and using Transportation card or Credit card can cause security problem, you may not receive A/S or compensation for any damages in case of that.Caution

Rubber Magnet(For single door)

Stopper(Stopper for door holding)

AA Battery : 4ea (Alkaline)

Installation DrawingUser Manual Warning Sticker

Outer Body : 1ea Indoor Body : 1ea Holder Clip Holder (seperately purchase)

※Card/Tag may be changeable in shape & color※Supplementary Components, quantities may vary according to its access type.

※The shape of Remote control may change.

④Reset button⑤9V Emergency Power Terminal

①Password button②Start/Ending button③Card/Tag input part (Card/Tag Applied Model)

①Battery cover②Input Button③Manual Operating Device

④Open/Close button⑤Dead Bolt (Keeper)⑥Auto lock internal sensor

⑥④

▣ Installation (Glass door lock without fixing plate)

Installation Tips!1. Sprinkling a little water over Glass door help you install easier.2. Depending on door condition, having silicone coating around the doorlock can help prevent from slipping off.

▣Registering: Press input button one time and then press any button of remote control. It informs you of successful registering with "ding dong dang" sound. (Register within 8 seconds)▣Deleting: Press input button one time and then press "5" button two times. Lastly press “✽”button to complete. ✽Remote control can be registered up to 15ea▣Opening/Closing Door is closed or opened within 2~3 seconds after pressing the button. ✽Frequency: FM447.275Mhz ✽Battery: AAA Size X 2EA (CR2032 1EA)

*Keep the door open while registering and checking password that it is normally registered.

1. Open the battery cover in the indoor body, and press Input button one time. ("Beep" sound will occur.)2. Input the new password. (Up to 3 to 19 digits can be registered.)3. Press “✽” button to complete the registration. (“ding-dong-dang" sound will occur to inform you of successful input.)

1. Open the battery cover in the indoor body, and press Input button one time. ("Beep" sound will occur.)2. Contact each Card/Tag to be registered to the external input part to the machine. Up to 50 keys can be registered. 3. Press “✽” button to complete the registration. “Ding-dong-dang” for success. ("Beep" sound for failure.)

4 Using Remote Control (Applied model only)

5 Password Registering

8 Card/Tag Deleting (Card/Tag Applied Model)

7 Card/Tag Registering (Card/Tag Applied Model)

6 Password Changing

- To go to the next stage, perform it before the lamp turns off (within 15 seconds).

- Never fail to register and change the password with the door opened. - The password is set to “1234” at the factory. - After installation, necessarily change it before use.

- Register the card/Tag only provided from the manufacturer.- Rregistering and using Transportation card or Credit card can cause security problem, you may not receive A/S or compensation for any damages in case of that.

* Register the password with the same method as specified above. * When the new password is registered, the existing password is automatically deleted.

1. Open the battery cover in the indoor body, and press Input button one time. ("Beep" sound will occur.)2. Two times press “0” button on the digit board in the outdoor body.3. Press “✽” button to complete the deletion.

When the Card/Tag is deleted, existing registered Card/Tag are completely deleted. Then, newly register Card/Tag to be used.

Open/Close button

How to change left-side door or right-side door.

1.Open battery cover.2.Insert screwdriver through a hole.3.Unscrew the fixed one.4.Pull the front body outward to come off.5.Turn it halt 180̊ and fix it with the screw again.

Alarm systemis working

Page 2: SGDL TG11 Safety Notes Components Name of the parts … Door Lock...Read through this manual before use. ... its contact point, ... Lot PT355, Jalan TPP5/1,Tmn Perindustrian Puchong,

Product Name

Serial No.

Date of Purchase Buy ( . . . ) From 1Year (12Months )

Customer Name

Address

Agent(installation

shop)

Name Tel:

Address

▣Product Warranty (for customer’s use) ※When request the repair, necessarily present this product certificate.

TEAMWARE HARDWARE SDN BHD Lot PT355, Jalan TPP5/1,Tmn Perindustrian Puchong, Sec 5, 47100 Puchong, Selangor D.E. Malaysia

Warranty 1.This product has been manufactured based on the strict quality control and inspection process. 2.If there is any defect in this product, you can receive an after-sales service free of charge for one year on condition that you have used it normally. If any defect occurs within the warranty period, but it corresponds to a charged repair condition as specified in this certificate, the service charge (repair expense + parts expense + dispatch expense) will be imposed. 3.This product certificate is applied in Korea only. 4.When requesting the repair, present this product certificate. 5.This product certificate is not reissued. Therefore you should keep it with caution. 6.If the product is relocated by a move, both installation expense and dispatch expense will be charged. 7.Once the product is installed on the door, it cannot be returned or exchanged except failures arising from important defects. (Complies with the consumer damage compensation criteria)

When Requesting Services 1. Before requesting services, check the usage and troubleshooting as specified in the user manual once again. 2. If there is nevertheless any defect, stop operating and contact the purchase agent or the main office. ※Repair at your disposal may cause a danger. ※If you contact, inform us of details as followings: Model name, purchase date, purchase agent / address, name, telephone number, home location(address) / trouble symptom(in detail)

TEAMWARE HARDWARE SDN BHDLot PT355, Jalan TPP5/1,Tmn Perindustrian Puchong, Sec 5, 47100 Puchong, Selangor D.E. Malaysiawww.stguchi.com.my.

“You must be aware of how to operate it in preparation for emergency.”- Keyless Door Lock .“Caution: This product is a keyless door lock. When it is out of order, it may be partially damaged for repair.”

1. Rated voltage : DC 6V2. Insert batteries into the battery compartment in conformity to polarity. Reverse insertion of batteries may cause fluid leakage or damage to the machine.3. When the battery is flat, please replace all batteries to new ones. 3. Replace all of used-up batteries at a time by new spares. Do not use new batteries together with batteries which are being used or have been completely used. 4. Sensor operation temperature : 60℃ (±10℃)

9 Door Opening

15 Lock Error Check

16 Burglar and Malicious Action Alarm Function (Warning Function)

17 Sound Control Function (Iower Sound ↔ Higher Sound)

20 Opening the Door with Spare Batteries

21 Product Specification

22 Trouble Diagnosis and Troubleshooting

23 Consumer Damage Compensation Criteria

19 Battery Exchange Method ▣Opening the door using the password from the outdoor

1. Touch the screen with fingers to light numbers on. ("Beep" sound occurs and the digit board lights on) 2. Enter the input password. 3. Press “✽” button, the door will be opened.

When the door is not closed normally, the machine will try to lock three times and then “Beep” sound will occur to inform you of an error.* The bolt err in the external alarm lamp lights on.

When the door is forcedly opened from the outdoor, the emergency alarm sound will occur for 1 minute and inform you of the entrance of outsiders.* Input the password or the RF card, and the alarm will be released.

Press Input button▶“1” and “3” buttons▶“✽” button▶“1” button several times for lower sound and “3” button several times for higher sound▶“✽” button.

▣Opening the Door with the Password Contact 9V battery to the emergency power terminal → Touch the screen with fingers to light numbers on and input password. → Touch "✽" button. Then the door will be opened.

▣Opening the door with the Card/Tag (Card/Tag applied model)Contact a 9V battery to the emergency power terminal and then contact the Card/Tag to input part, and the door will be opened.

▣Opening the door using the Card/Tag from the outdoor (Card/Tag applied model)

▣Opening the door from the indoor

If the built-in battery voltage gets downed, the lamp blinks before 7days and a saved melody rings. You should replace all of them by new spares. The password or Card/Tag registered are not changed in spite of the exchange of batteries.

When batteries are completely discharged due to long-time going out or traveling, you can open the door with safety using the emergency power terminal. Purchase a DC 9V rectangular alkaline battery in the market, contact it to the emergency power terminal in the outdoor body and use the password or the Card/Tag to open the door.

- If new batteries are used together with used ones, their life cannot be guaranteed and the machine may not work normally. - If rechargeable batteries are used, the machine may not work normally. Check battery polarity (+/-) before insertion. Abnormal insertion results in error-working. - If any defect occurs due to the use of bad batteries, it is attributable to the customer. Use genuine alkaline batteries only.

Never fail to use this function on condition that the battery contacts to the emergency power terminal. (Regardless of the polarity(+/-))

- In case five times errors of the password, the machine does not work for 1 minute. - When the machine has not worked, you should use it in one minute.

Press Open/Close button to open the door.

Contact the registered Card/Tag to the Card/Tag input part in the outdoor body. “ding-dong-dang” sound will occur and the door will be opened.

The manual operating device should be used for fire or emergencies only.

10 Door Closing

11 Dual Lock Function

14 Password Exposure-proof Function (Built-in Dummy Number System)

18 Fire Sensing Function (Built-in Fire Detection Sensor)12 Reset function

13 Auto/Manual Lock Setting

▣Closing the door from the outdoor- Auto mode : Close the door, and it will be automatically locked in one second.- Manual mode : Touch the screen with fingers and press # button to lock.

▣Closing the door from the indoor - Auto mode : Close the door, and it will be automatically locked in one second. - Manual mode : Press Open/Close button to lock the door.

※The manual operating device should be used for fire or emergencies only.

▣External dual lock (burglar prevention through a slot) When the external dual lock is set, the door does not open in spite of pressing Open/Close button from the indoor.

✽Setting: Touch the screen with fingers to light numbers on and touch "#" button for 5 seconds long. (Ding-dong-dang sound occurs.)

✽Cancellation: Open the door lock using password one time to disable this function.

▣Password exposure-proof functionBy adding the dummy number function, remove a risk of password exposure.

▣How to use the dummy number functionBefore inputting passwords, press random digit buttons without limitation and then input the password, and the password will be concealed.

When the thermal detection sensor detects heat (60℃±10℃), the door will be automatically opened. ▣Temporary program error can be solved and back to normal operation.- How to use: Pass through a hole and press this button one time with sharp pin.※Pin code dose not change with this action.

▣Easy function to lock the door automatically in one second after closing it.- Auto mode : Press Input button once▶# button ▶Input button once (“ding-dong-dang”sound)- Manual mode : Press Input button once▶# button▶Input button once (“beep”sound)

▣Auto lock time is changeable up to 2 to 9 seconds.- Press Input Button▶“8” button▶desired times (“2”~”9” buttons) ▶“✽” button.

Symptom Troubleshooting

The password is not memorized. - Use the Card/Tag to open the door, and input the new password. - If the Card/Tag is not input or lost, contact A/S center.

Card/Tag is not registered. - Use the password to open the door. When the password is not memorized, contact A/S center.

There are 5 times errors of the password.

- In case of 5 times errors, all operations are stopped for about 1 minute. Wait during the given time and then input the password or the touch key again from first.

The door is not automatically locked. - Check that the auto lock function is set to Auto mode.

When pressing “✽” button, the machine does not work.

- If other functions do not work as well, check that batteries are normally inserted. If the batteries are used up, replace them by new spares.

External button tone and the lamp do not work.

- Check that there is any fluid leakage in the battery case or the machine. If it is so, clean up contact portions with a dry cloth.

Customer Damage TypeCompensation Scope

Within Warranty Period After Warranty Period

When the machine is normally used

When any trouble occurs within one year after installation. Free repair Charged repair

When the same defect occurs more than two times. Free repair Charged repair

When there is no part for repairing. Exchange of product Exchange of product (Based on fixed depreciation rate)

When there is any intension or mistake of the

consumer

When our engineer is dispatched because of the user’s mistakes such as wrong exchange of batteries, inappropriate input method and so on.

Charged repair Charged repair

When consumables like batteries are exchanged. Charged repair Charged repair

When there is any trouble or damage due to use except the original purpose of the product. Charged repair Charged repair

When there is any trouble or damage by intension. Charged repair Charged repair

When there is any trouble or damage due to a fire and natural disasters. Charged repair Charged repair

▣Free-of-charge / Charged Repair (based on details)The service charge is imposed to the actual expense based on the Consumer Protection Act enacted by the government.(As specified in Article 5 of Consumer Damage Compensation Criteria of the Consumer Protection Act) The service charge is composed of parts expense, dispatch expense, repair expense. They are concluded as follows. Service charge = parts expense + dispatch expense + repair expense (the number of repair items)■ Free service: The product is damaged on the function or working within warranty period in normal operation.■ Paid service: Over the warranty period or the cases as listed below. Wrong use / Trip for asking how to use the products / Missing the access-code(Key) / Checking the normal products / Damage when the user install the product / Damage by an impact / Damage for using the wrong battery / Cover damaged while changing the battery / Damage by chemical / Reinstallation by wrong installation(Adjustment of front position) / Damage by not carrying the emergency key(Emergency key-applied moddel)■ Parts Expense: When the product is repaired, the parts may be replaced by a spare. The parts expense means the price of the spare (including 10% VAT). ■ Dispatch Repair Expense: This is applied to products to be repaired in a charge, which is the amount added the required dispatch fee to the technical fee according to the difficulty (hour) of product repair.

The warranty period is one year after purchasing. (Never fail to specify the date of purchase on the product certificate.)

Category Description

Basic information

Access-Code 3 ~ 19 digits

Card/Tag registration number Within 50

Thickness of the door 35 ~ 50mm

Operating temperature -20℃ ~ 60℃(no dew condensation)Outdoor body Size 70.5 (W) X 169.5 (H) X 20 (D) mm

Indoor body Size 72.4 (W) X 174.4 (H) X 47.65 (D) mm

Material Outdoor body: AL, ZN, PC, ABS / Indoor body: AL, ZN, ABS / Treat the surface: Triple metallic coating

PowerWorking power 6V (alkaline battery 1.5V × 4 ea, AA SIZE)

Emergency power 9V rectangular alkaline battery (separately purchased)

Card size 85.6mm(W) x 54mm(H) x 0.8mm(D)Card frequency 13.561Mhz