ISSUE: SG900/MAY2001/UK
accuracy to 0.2% reading
integral sample conditioning
fast response
absolute density, temperature and pressuremeasurements
options to suit all applications
intrinsically safe design
corrosion resistant construction
option for heated enclosure
no on-site calibration required
SarasotaSpecific Gravity Analyser
SG900
Features
The Sarasota SG900 specific gravity analyser is designedfor high accuracy measurement of gases.
Applications• energy determination • blending control • standard volume flow calculation • fuel gas monitoring
800m
m
300mm600mm
800m
m
Dimensional drawing
Detailed specification and ordering information: see overleafThermo Measurement reserves the right to alter specifications without notice.
Specification
Thermo Electron CorporationKing’s WorthyWinchester, HampshireSO23 7QA, United Kingdom
Tel: +44 (0) 1962 625000Fax: +44 (0) 1962 885530email: [email protected]
Thermo Electron Corporation9303 W. Sam Houston Parkway SouthHoustonTexas77099 – 5298 USA
Tel: +1 (713) 272 0404Fax: +1 (713) 272 2273
System:Range: UnlimitedAccuracy: ±0.2% reading Repeatability: ±0.02% span Temperature coefficient: 0.01%/°COperating temperature: -20 to +55°C or as limited by gas
dew pointSample inlet pressure: 20 bar maximum for basic systems
200 bar maximum for dry and wet gas systems
Exhaust pressure: Maximum 4 Bar AMaterials of construction: Spool - Ni-Span-C or FV520B
Body - AISI 316L stainless steelEnclosure - GRP
Temperature measurement: High accuracy 1⁄3 DINThermowell 4 wire PT100
General:Environmental protection: IP65Hazardous area certification: Intrinsically safe with approved barriers
Weight: Nett 30kg maxShipping 65kg max
Installation: 1⁄4” tubing compression fittingFlow range: Ideally 4-20 litres/min
Outputs:Frequency related to density on 2 wirecurrent modulated loop 6mA to 18mA4 wire PT1004-20mA pressure
Electrical:Power supply: 16-28 VDC 10mA average (peak 18mA)
(density transmitter)9-30 VDC 20mA(pressure transmitter)
Connections: Screw terminals
Ordering Information
Example: SG900-F-D-O-Z-I
SG900 specific gravity analyser with frequency output, suitable for dry gas, no internal heating, with Ni-Span-C spool for intrinsically safe application.
Density meter model code format
SG900 Sarasota Specific Gravity Analyser
Signal output
F Frequency output
System type
B Basic system
D Dry gas
W Wet gas
Internal heater
O No internal heating
E Electrical heater
S Steam heater
Spool material
Z Ni-Span-C
Y FV520B
Certification
S Non hazardous / safe area application
I Intrinsically safe EEx ia IIC T4/T6
Options
M Wetted parts material certificates (DIN 50049 BS EN 10204 3.1b)
N NACE conformance
T Traceable calibration certificate for density meter