WEIGHING INDICATOR
SI3010A
- INSTRUCTION MANUAL -
S E W H A C N M C O ., L T D
WEIGHING INDICATOR
SI3010A
1
Expression method of Caution
This mark arrives in case of there is possibility that encounters defamation
in death in human body in case do wrongly use.
This mark injury when can produce docking or material damage in case do
wrongly use.
About terminology and mark
Meaning of terminology and mark that is used to the instruction manual is as following.
: There is place with worry of electric shock. Never touch on hand.
: Mark protective ground terminal.
: Mark prohibition item of use.
Inquiry item
Inquiry item for this product purchase company or to communicate to head office desire.
Also, can inquire by E - mail or head office homepage.
Add. : #310, Kolon Techno Valley, 60-4, Kasan-Dong, Keumcheon-Ku, 153-801 Korea
Tel : (82 – 2)868 - 0701 Fax : (82 – 2) 868 - 0705
Website : www.sewhacnm.co.kr
e-mail : [email protected]
Caution
(1) Prohibit part or all substance of manual reproduction. (2) Substance of manual can be changed without advance notice. (3) If contents of manual that see mistook or there is inquiry item of place and so on that
recording is omitted, communicate to purchase company or head office.
warning
caution
WEIGHING INDICATOR
SI3010A
2
CONTENTS
1. PREFACE ……………………… 3
2. SPECIFICATION ……………………… 5
3. FRONT PANEL ……………………… 6
4. REAR PANEL ……………………… 8
5. INSTALLATION ……………………… 11
6. CALIBRATION ……………………… 12
7. SET-UP ……………………… 16
8. INTERFACE ……………………… 25
WEIGHING INDICATOR
SI3010A
3
Chapter 1. PREFACE
1-1 For the Safe Usage
Plz, Read following information for safety before using our Digital Weighing Indicator.
▶ Ground Ground is essential for this SI-3010A.
Make ground with ground terminal of behind panel and surface of factory.
And plz, isolate with Power Drive deices, like Motor or Inverter
If you don’ t make ground, it can be happened Electric Shock damage.
▶ Power Cable Please, Use optimal capacity Power cable after checking Power consumption. If you use Low
resisting pressure cable, it can be happened electric leakage or fire.
▶ Fuse Replacement To prevent Fire accident, we applied fuse inside. Under the normal operation, fuse will work
properly, but under Power supply problem or inside kit damage, fuse will be harmed.
Under fuse damage, please contact distributor or Head office, instead of replace by
operators.
▶ Protection from Heat For the protection from heat, please install with optimal distance between other devices.
▶ Disassembly of Digital Weighing Indicator SI-3010A uses AC100V ~ AC240V Power supply.
In case of you have to open the SI-3010A cover, open the cover at least 10sec after removing
power. When you close cover, please make sure if there is metal contaminant inside
SI-3010A.
1-2 Introduction
This SI-3010A is the digital weighing indicator which is a simple basic model for wide
range of weighing application. This indicator has a standard Serial Output Interface (RS232C
& CURRENT LOOP) & Printer Interface (Serial Printer) for easier connection with another
indicator, P/C, Printer or external remote display. The Wide Display gives the operator easier
recognition of the Displayed Weight. This indicator is provided with user’ s friendly
programming for easy key operation and set-up of function. External remote display and
Relay output are available as option.
WEIGHING INDICATOR
SI3010A
4
1-3 Main Features
1) Large Display for easy reading from remote places. 2) FAC ( Full Auto Calibration ) 3) SMPS power supply -- wide Input Volt range 85V ~236V 4) SMPS power supply -- more lighter 5) Display Resolution : 1/20,000 6) Serial interface (RS232C & Current Loop) & Printer Interface built-in as standard.
Relay output as option
7) Photo-Coupler protection against external noise 8) Watchdog circuit for operation-mistake protection and self-diagnostic. 9) Data memory back-up (no need battery) 10) Weight back-up when power is off or down 11) External control input built-in (duplicated front key function, Zero, Tare, Hold, Hold
reset)
12) Data memory function 13) Option
① Serial I/F : RS-422, RS-485, Serial Printer
② Relay Out : HI, LOW
③ Analog Out : 4mA ~ 20mA, 0V ~ 10V
1-4 Precaution
1) Avoid subjecting the indicator to sudden extreme temperature change.
2) Keep away from high-voltage cable or other devices that produce electrical shock or
noise.
3) Power off when connect to other peripheral devices. 4) Keep the indicator in a dry place. 5) Avoid extreme shock and vibration
● The Breakage or Disorder from User’ s Careless Treatment & Operating will not
covered by the Product Guarantee Terms.
1-5 Accessories
1) Power cord ………… 1 EA, 1.5m
2) Fuse (AC250V /1A) ………… 2 EA
3) Load cell connector ………… 1 EA
4) Serial output connector ………… 1 EA
5) Instruction manual ………… 1 EA
6) D-type 9Pin Connector ………… 1 EA
7) Hood ( D-type 9Pin) ………… 1 EA
caution
WEIGHING INDICATOR
SI3010A
5
Chapter 2. SPECIFICATION
2-1 Analog Input & A/D Conversion
2-2 Digital Part
Display Weight 7-Segment 6digit FND ,red
Size : 25.4(H)*14.8(W)㎜
Min, division X1, X2, X5, X10, X20, X50,
Max. display value +999950 Display Value
Decimal point position 0, 0.0, 0.00, 0.000, 0.0000
Status lamp Steady, Zero, Tare RED LED
2-3 General
2-3 Options
※ In case of RS422&485 OPTION CARD installed, please make sure
“ CORE” to be winded with I/F cable two times as left pictures show.
I/F cable for winding shall be “ SHIELD CABLE (24#AWG X 4C)”
◆ RS-232C, Current Loop :Standard Installed.
Input sensitivity ≥ 0.3㎶ / D
Zero adjustment range 0.6mV ∼ 2.7mV
Load cell excitation DC 10V (±5V)
Load cell output Max.27mV
Temperature coefficient ZERO : ±20 PPM / ℃
SPAN : ±20 PPM / ℃
Input noise ±0.6㎶ P.P
Input impedance 10㏁
A/D conversion method ∆ ∑
A/D resolution 520,000 Count(19bit)
A/D conversion rate 200times/Sec
Non-linearity 0.01% FS
Power source SMPS Free Voltage (85V~236V)
Operation temperature 5℃ ∼ +40℃
Max. humidity 85%Rh (non-condensing)
Physical dimensions 200(W) * 105(H) * 135(D)㎜
Product net weight Appr, 1.2㎏
OP1 Relay Out (Low, Hi)
Serial I/F (RS-422, RS-485) OP2
Analog Out (4mA ~ 20mA, 0v~10v)
WEIGHING INDICATOR
SI3010A
6
Chapter 3. FRONT PANEL
3-1 Status lamp (annunciator)
ZERO : Lamp is on when weight is zero.
STEADY : Lamp is on when weight is stable.
(In order to get the exact weight, please check out the value after “ STEADY” )
TARE : Lamp is on when tare weight is subtracted.
(For weighing Powder Products or Anything which need the TARE, this function will
make the Tare weight to “ DEAD LOAD” , so you can get the “ NET WEIGHT”
with TARE excluded.)
●
●
●
WEIGHING INDICATOR
SI3010A
7
3-2 Standard Key Function
* Several Key works either a single function or compound functions.
This key is to return to ZERO when the weighing device is empty
(the end-user Selected Cover Range within 5%, 10%, 20%, 100% by SET-UP F08)
EX > “ F08-02” set-up
Max. Capacity = 5000g
5000 * 1/10=500g
Displayed Value is 500g or less, press Key to return to “ 0” value.
This key is used to make “ TARE” weight to “ 0”
(This key is to return to ZERO when TARE is loaded on the weighing device (the
end-user Selected Cover Range within 10%, 20%, 50%, 100% by SET-UP F09)
This key is used to capture & display “ MAX.WEIGHT“ (Peak Hold) from the
moving weight value.
This key is used to remove “ HOLD” function.
3-3 Hidden Key Function
① This key is used to increase numeric value (rotated).
② to check out “ A/D conversion Value” under Test Mode.
① This key is used to move position of blinking digit to the left.
② to check out “ KEY VALUE” under Test Mode
① This key is used to move to next F-function under “ SET-UP Mode”
② to move Calibration Mode & Set-Up mode under Test Mode.
EX> Under Test Mode,
Press -- Calibration Mode, and Press again -- Set-Up Mode.
③ “ Under Limit” setting (under “ F11-01” condition)
① This key is used to record the settled data.
To move to the next step of the Calibration ( under Calibration Mode)
to record the new F-Function Data (under Set-Up Mode)
② “ Upper Limit” (under“ F11-01” condition)
WEIGHING INDICATOR
SI3010A
8
To prevent electric shock or malfunction, please make sure ground
process. If you don’ t make ground process, there is possibility of electric shock danger
and Indicator malfunction
Chapter 4. REAR PANEL
① POWER AC IN
- Power switch : Power on/off switch
- Fuse : AC 250V 1A
AC IN : SMPS free Voltage, Available Input AC 100V ~ 240V
② OPTION 1
③ OPTION 2
- Option Board Connector installed for Optional I/F
- Analog Out, Serial I/F, Relay Out
④ C-Lock( Calibration-Lock)
- This C-Lock Function prevent the accidental Calibration by an unauthorized
person.
- According to Key position : Right side – lock ( can not calibrate),
- Left-unlock (can calibrate)
※ LOCK Switch
⊙ Under the power is on, if you move Lock Switch to side, you can enter Calibration
mode.
⊙ If you can not move the Lock Switch, please contact our agent and have treatment for
the Calibration.
⊙ After finishing the Calibration process, you have to return Lock Switch to the original
position for the normal operation.
① ② ③
④
⑤
⑥
⑦
WEIGHING INDICATOR
SI3010A
9
Don’ t touch C-Lock switch, except Calibration process.
If you move C-Lock switch with your own intention, the weight could be incorrect.
⑤ LOAD CELL CONNECTOR (N-16)
EC+ …………………………… PIN 1(red)
EC- …………………………… PIN 2(white)
SIG + ………………………… PIN 3(green)
SIG - …………………………… PIN 4(blue, black)
SHIELD ………………………… PIN 5(Yellow)
Red
white
green
blue, black
shield
WEIGHING INDICATOR
SI3010A
10
* The wire color of load cell according to a manufacturer
No.1
(EX+)
No.2
(EX-)
No.3
(SIG+)
No.4
(SIG-)
No.5
(SHILD)
SEWHA Red White Green Blue Shield
CAS Red White Green Blue Shield
BONGSHIN Red White Green Blue Yellow
JEONGWOO Red White Green Blue Yellow
KYOWA Red Black Green White Shield
INTERFACE Red Black Green White Shield
P.T Red Black Green White Shield
BLS Green Black White Red Yellow
SHOWA Red Blue White Black Shield
SHINKOH Red Black Green White Shield
TMI Red White Green Blue Yellow
TML Red Black White Green Shield
TFAC Red Blue White Black Yellow
HUNTLEIGH green Black Red White Shield
● Because Wire color may be different according to a manufacturer and load cell models.
⑥ SERIAL I/F
- RS232C/CURRENT LOOP standard installed (9p-D-TYPE female)
Pin No. Description Pin No. Description
1 No Connection 2 Receive Data
3 Transmit Data 4 No Connection
5 Signal Ground 6 Current Loop RXD
7 Current Loop RXD 8 Current Loop TXD
9 Current Loop TXD
⑦ EXTERNAL INPUT
This Port will be used for connection with External Controller.
Each Function of Input Port, please refer to “ F-11” function.
WEIGHING INDICATOR
SI3010A
11
Chapter 5. INSTALLATION
5-1 Physical Dimensions And Panel Cut Dimensions (Unit):mm
WEIGHING INDICATOR
SI3010A
12
Chapter 6. CALIBRATION
▣ What is Calibration?
Calibration is to adjust Max. weight, minimum, division, decimal point displayed to Indicator
To the actual weight worked by load cell.
● It should be calibrated certainly when load cell or indicator will be changed.
6-1 SPAN ADJUSTMENT
▣ What is Span Adjustment.
Span adjustment is to make the display value from "0" to max.weight consistent to the actual
weight through linearity adjustment.
▶ENTER SPAN ADJUSTMENT
① Unlock the Seal of C-Lock in rear panel, and move “ C-Lock” key to Left position,
and then power on. ----- “ TEST “ display.
② Press Key --- “ SEt, CAL “ display.
Press Key --- “ d__XX “ display.
6-2 ZERO ADJUSTMENT
▣ What is zero adjustment.?
The meaning of ZERO is the fiducial point of weighing operation.
SI3010A do Full Auto Calibration in itself, very easy to execute Zero Adjustment.
● SI-3010A will execute “ Zero Adjustment” automatically in itself, the customer do not
need to any other calibration procedure for “ Zero Adjustment” separately.
● In case of “ 5000” ±10% “ not display, please contact the manufacturer or seller for
more detail..
WEIGHING INDICATOR
SI3010A
13
▶ SPAN ADJUSTMENT
Total 6 Steps composed. Key & Key are used to move back & forth in Span
Adjustment.
move to the next step : press Key
move to the previous step : press Key
Ⅰ. STEP 1 ( ☞ A step to set up a Division Value )
* "d" menas "Division" and "XX" means “ A Displayed Division Value “ .
* “ XX” (division value) changes “ 01-02-05-10-20-50” consecutively by
pressing Key.
* Please select the hopeful “ XX” (division value), then press Key to
be memorized & move to the next step.
Ⅱ. STEP 2 (☞ A step to set up Decimal Point Position)
“ dp” means “ Decimal Point “ to set up a Decimal Point Position
(=Dot Positiion)
--- under “ dp ” displays
--- press Key, then Decimal Point twinkles
--- press Key, then Decimal Point moves to left position.
--- please select the hopeful Decimal Point Position and press Key
to be memorized & move to the next step.
● Decimal Point Position can move up to 4 position.
Ⅲ. STEP 3 (☞ A step to set up Max. Weight )
“ CAPA” means “ Capacity “
The display will appear "CAPA"(Capacity) and discretion
number(max.6figure)
It can input the maximum weight as the end-user demands instead of
discretion number.
--- under “ CAPA “ displays.
--- press Key, then Max. Weight twinkles
--- press the hopeful Numeric Value (New Max. Weight) by pressing
key & Key.
--- press Key to be memorized & move to the next step.
WEIGHING INDICATOR
SI3010A
14
● Don`t excess the resolution (=A division / Max.weight) over 1/20,000
If excess rate is over 1/20,000,it will appear “ Error” message..
Ⅳ. STEP 4 (☞ A step to compensate the weighing plate to dead load )
--- under “ Unload” condition
--- pls make sure the weighing plate empty
--- press Key, then SI-3010A will execute the compensation process
in itself
--- after 5 secs, move to the next step automatically.
Ⅴ. STEP 5 (☞ A step to set up the Span Weight )
A step to set up the Span Weight for Max. Weight.
※Basically, Standard Weight for Span Adjustment shall be the Max. Weight
(Full Capacity) but in case of impossibility, Please input the value of standard
weight over 10% of Max. Weight.
This value of span standard weight must be equal to full capacity,or over 10%
of full capacity.the
--- under “ SPAn” display condition,
--- press Key, then input numeric SPAn value by , Key
--- press Key, then the SPAn Value shall be memorized
--- then, “ uPLOAd” displays.
--- upload the span standard weight on the weighing plate, then press
Key to be memorized & move to the next step.
▶When you set 100.00㎏ as Max. Capacity,
If you don’ t have 100.00㎏ capacity Test weight, you can make calibration
with using 10.00kg(over 10% of Max. Capacity)test weight, as a Span Capacity.
EEEXXX
WEIGHING INDICATOR
SI3010A
15
Ⅵ. STEP 6 (☞ A step to confirm SPAN ADJUSTMENT )
After STEP 5 finished, “ S-Con” display, then Sep-Up SPAN CALIBRATION
VALUE display, then “ End” display continuously.
--- please unload the Span Standard Weight from weighing plate,
--- press Key to confirm, then Indicator will move to user’ s
weighing mode.
--- please return “ C-Lock S/W” to Lock Condition ( in the rear panel
positioned)
--- please upload the Span Standard Weight on weighing plate to check
out if the correct weight displays or not.
※When you set the Test weight capacity
* In case of less 1/5,000 resolution ,the value of standard weight must be over 10% of full
capacity at least.
* In case of over 1/5,000 resolution ,the value of standard weight must be over 20% of full
capacity at least.
---- If span capacity is set less 10% of full capacity ,indicator will display “ Error 05”
If span capacity is set more than full capacity, indicator will display “ Error 04”
6-4. ERROR MESSAGES & SOLUTION
No. Message Cause Solution
1 Err 01 In case resolution (Division / Max.display weight) was set over 1/30,000 resolution.
☞ Set under 1/30,000 resolution( Division l/Max.display weight)
2 Err 04 In case “ SPAN STANDARD WEIGHT” was more than Max CAPACITY
☞ Make Set “ SPAN STANDARD WEIGHT” equal or less than Max CAPACITY
3 Err 05 In case “ SPAN STANDARD WEIGHT” was set less than 10% of Max CAPACITY
☞ Set “ SPAN STANDARD WEIGHT” for span adjust into less than 10% of Max CAPACITY
4 Err 06 Load Cell Output is too big
☞ check out if “ SPAN STANDARD WEIGHT”which is uploaded on the weighing plate is equal to the setting value. And please make sure both value same.
5 Err 07 Load cell Output is too small
☞ check out if “ SPAN STANDARD WEIGHT” which is uploaded on the weighing plate is equal to the setting value. And please make sure both value same.
6 Err 08 Weight is not stable.
☞ Remove the vibrating substance. ☞ check out Load cell defectiveness ☞ check out Connection between Loadcell
& indicator ☞ check out Loadcell wiring condition
7 Err 09 Incorrect data is entered in F-Function
☞ check out correct data & reset
WEIGHING INDICATOR
SI3010A
16
Chapter 7. SET UP 7-1 Set-Up
● PROFILE " SET-UP " is to choose each proper functions for matching the indicator with the appliances of
field.
▶ How to enter into set-up mode
☞ Step
- While key pressed and power on at the same time, then "TEST" display on
indicator.
- Depress key again, and indicator will display as following
SET, C A L. ; S & C Mode
- press key again, then Indicator will display to " F01-xx " from above test
message.
▶ under “ POWER OFF” condition
① while Key pressed, power on at the same time. – “ TEST” display
② press Key – “ SET,CAL “ display
③ press Key – “ F01-XX “ display
※“ Χ " is the number
EEEXXX
WEIGHING INDICATOR
SI3010A
17
▶How to move the next F-FUNCTION No.
☞ Step
- prss Key continuously, then F-FUNTION change from F00, F01, F02,…..up to F48,
then return to F00 again.
- If want to move F-11 directly, under “ F-01” condition, please input “ 11” by using
, Key, then press Key
▶How to set up F-Function
Under F-XX condition, please input the hopeful Function No., then press Key to be
memorized.
● Please make sure to press key to be memorized of new Function, Otherwise, Function
will not change.
▶ under ” F01-01 “ condition
① press Key - “ F02-XX” display
② press Key - “ F03-XX” display
③ pressing Key at a time, No. of FXX increase by one Number.
▶ want to move from F01-XX to F80-XX directly, under “ F01-XX” condition,
① input “ 80” by using , Key
② press Key
EEEXXX
▶Under “ F01-02” condition, if want to set up ” F01-03”
press Key ---- “ F01-03 “ display
press Key to be memorized.
EEEXXX
WEIGHING INDICATOR
SI3010A
18
7-2 F-Function List
F-Function Function Contents
F00 Set-Up&Calibration Mode Convert SET & CAL Key
F01 Decimal Point Position 0, 0.0, 0.00, 0.000, 0.0000
F02 Weight Back up Normal(0), Back – UP(1)
F03 MOTION BAND Range 0, 1, 2, 3
F04 ZERO TRACKING Range 0, 1, 2, 3
F05 AUTO ZERO Range 00∼99
F06 Digital Filter Range 1∼9
F07 ZERO, TARE Key Operate mode Stable condition (0), unstable condition(1)
F08 ZERO Key Operate Range 5%(0), 10%(1), 20%(2), 100%(3)
F09 TARE Key Operate Range 10%(0), 20%(1), 50%(2), 100%(3)
F10 Hold Range Peak Hold (0), Average Hold (1)
F11 Selection of External Input
0:(Zero, Tare, Hold, Hold reset ), 1:(zero, Tare, Lower Limit, Upper Limit),
2:(zero, Tare, subtotal, print) 3:(zero, Tare, Tare reset, Set-Up)
F12 Display speed 1∼9
F30 Serial Parity Bit mode NON(0), ODD(1), EVEN(2)
F31 Serial Baud Rate
38,400(0), 19,200(1)
9,600(2), 4,800(3), 2,400(4), 1,200(5)
F32 Serial Transmission rate 0 : Stream Mode, 1 : stable Mode,
2 : Print Key Mode < F11 : 2 setting >
F33 Serial Communication Mode 0 : Direct Mode, 1 : COMMAND MODE
F34 ID NUMBER 1∼99
F35 Data FORMAT 0 : basic FORMAT , 1 : CAS FORMAT 2 : TIME inclusive FORMAT, 3 : PRINT FORMAT
F40 Select the unit of Print 0: g, 1:kg, 2:ton
F41 Printing mode 0 : print when the value is under F80 setting value ,
then increase over F80 setting value
F42 Printing type selection 0 : consecutive print, 1 : individual print
F43 Sub or Grand Total clear 0 : subtotal delete (subtotal key pressing for 5 sec)
1 : auto delete when print
F44 Setting mode for line interval As 1Count increase, 1 line increase
F45 Setting mode for line feed width From one line up to next line
F46 Setting mode for sub-total print 0 : manual( print Key), 1 : one time print in stable
F47 PRINT Character selection 0 : Korean, 1 : English
F48 PRINT Key Output mode Print output
F49 Re-Set for the Zero Value 0 : Impossible , 1 : Possible ( Default : 0 )
F80 NEAR ZERO(EMPTY) range x x x x x x
F81 Under limit (LOW), code No. in print x x x x x x Relay output installed condition
F82 Upper limit(HI) x x x x x x Relay output installed condition.
F89 Calibration SPAN value confirm x. x x x x x
F90 date(month, date) confirm, amend x x. x x. x x
F91 time confirm, amend x x. x x. x x
WEIGHING INDICATOR
SI3010A
19
■F-Function Explanation
(● Factory set)
F00 SET-UP Key Set-up
Setting for position of decimal point
0 No decimal point 0
1 First decimal place 0.0
● 2 Second decimal place 0.00
3 Third decimal place 0.000
F01
4 Fourth decimal place 0.0000
Back-up of weight value
● 0 Normal Mode F02
1 Back-up Mode
* Normal Condition : In case of Sudden Power-Off, the indicator did not memory the actual weight
loaded on the weighing plate -- so, please power on with the weighing plate empty again.
* Back-up Condition : In case of Sudden Power-Off, the indicator did memory the actual weight
loaded on the weighing plate & zero adjustment - so, power on whatever the weighing plate empty
or not.
Setting of motion band range
F03 2
0
∫
3
This is the function, set the variation range of weight difference per
hour to display Stable condition of Indicator.
0 : Little Vibration(weak) ~ 3 : Much vibration(Strong)
* This is to compensate for the momentary vibration. If indicator is used in vibration area,
please set enough motion band range : High motion band range will shorter the leading time to make
decision “ STABLE” or not.
* Indicator admit “ STABLE “ weight subject to Weight Variation shall be within Set-up motion band
range.
WEIGHING INDICATOR
SI3010A
20
t
● This Function is to prevent the effect of the dust & mist accumulated on weighing plate
according to operating site & condition.
Setting of zero tracking range
F04 2
0
∫
3
The meaning of zero tracking?
In case of increasing the weight minutely by certain external
Facto(like Dust),this minute weight will be compensated to zero if it is
Within a flxed division and time
Ex) Under Max. display capacity is 120.00Kg, Digit is 0.05Kg setting, F04 set value is “ 3”
Auto – Zero setting
F05 00 00
∫
99
This is to make the weight of last two digits as to zero automatically
(To be applied for the disregarding of remaining weight in hopper,
tanker & etc)
※ This Function is to applied for disregarding of remaining weight in hopper, tanker & etc
automatically according to setting range. Without this function unset, the user press Key to make
“ ZERO” condition.
※ EX) Under Max. Capacity : 120.00Kg, division : 0.02Kg, F05 : 30------- Auto-Zero Setting will
ZERO or TARE Key Operation Mode
0 Zero or Tare operation is available only in stable state by Key F07
● 1 Zero or Tare operation is available only in unstable state by Key
Digital Filter Range
F06 2 0
∫
9
Low
↕
High
Low vibration
↑
High vibration
More Sensitive
Less Sensitive
※ This Function is to be set according to operating condition (environmental vibration)
※ The less setting value, the more rapid to display.
In case of 250g weight variation within 0.75SEC,
"0” display automatically
In case of 250g weight variation for
0.75 SEC, the actual weight display
5digit
(0.25Kg)
0.75 Sec
WEIGHING INDICATOR
SI3010A
21
※Indicator allow +10% tolerance, it means,
In case of setting Max. Capa. 100㎏-- Actual Max. Capa. can be 110㎏.
Ex) Max. Capacity : 100㎏, F09 : “ 2” -- within 50㎏,
Key operate.
ZERO Key Operation Mode
0 5% of Full Capacity
● 1 10% of Full Capacity
2 20% of Full Capacity F08
3 100% of Full Capacity
Tare Key Operation Mode
0 10% of Full Capacity
1 20% of Full Capacity
● 2 50% of Full Capacity F09
3 100% of Full Capacity
Holding Mode
● 0 Peak Hold F10
1 Average Hold (5 seconds)
① Peak Hold : Display is Locked when HOLD key is pressed or command input is ON. But,
Display will be replaced when new peak data is entered.
② Average Hold : Display is Locked after averaging data for 7 seconds when HOLD key is
pressed or command input is ON.
External Input Mode Selection
division IN1 IN2 IN3 IN4
0 Zero Tare(Tare Reset) HOLD Hold Reset
1 Zero Tare(Tare Reset) Under Limit Upper Limit
2 Zero Tare(Tare Reset) Sub Total Print
F11
3 Zero Tare Tare Reset Set-Up
WEIGHING INDICATOR
SI3010A
22
Serial Parity Bit
● 0 No Parity
1 Odd Parity F30
2 Even Parity
※ INTERFACE MODE
Serial Baud rate
0 36,400 bps
1 19,200 bps
● 2 9,600 bps
3 4,800 bps
4 2,400 bps
F31
5 1,200 bps
Display Speed Mode
F12 5 1
∫
9
Rapid Display
∫
Slow Display
Output Mode (When “ 0” is set in F33)
● 0 Stream Mode : Always output data
1 Stable & Auto Mode : Output data only when display is stable F32
2 Manual Mode : Output data only when PRINT key is pressed
Data Transfer FORMAT
● 0 Standard Format
1 CAS Format
2 Time Inclusive Format F35
3 Printer Format
Communication Mode
● 0 Stream (Simplex) F33
1 Command (Duplex)
ID Number
F34 1 1 ∼ 99 Set identification number for weighing device.
WEIGHING INDICATOR
SI3010A
23
※ CENTRONICS PARALLEL OUTPUT(PRINT INTERFACE)
※Under F11 : ‘ 2’ condition-- Key will operate as “ SUB” Key
Automatic Print Data Output
● 0 Automatic print when weight is within near zero band F41
1 Automatic print only when display is stable.
Weighing Unit Selection
0 g
● 1 Kg F40
2 ton
Printing Format
● 0 Print consecutive format with serial number and weight F42
1 Print individual format per weighing operation
Sub & Grand Total Data Clear
● 0 Manual clear : Sub Total Clear : Press “ CLEAR” key and “ SUB” key.
Grand Total clear : Press “ CLEAR” key and “ GRAND” key F43
1 Automatic clear : Automatically clear after printing
Paper Feeding Line
F44 1 1 ∫ 9
As 1 Count increase, 1 line increase
(Applicable to Individual Print or Sub-total Print only
Printing Line Interval
F45 1 1 ∫ 9
Printing line interval from one line to another
As 1 Count increase, 1 line increase (Applicable to consecutive Print only)
PRINT OUTPUT (AUTOMATIC, MANUAL)
● 0 Manual : Print when Print key is pressed F46
1 Automatic : Automatic Print one time when display is stable.(Stable Lamp on)
Printing Font (Language)
● 0 Korean F47
1 English
WEIGHING INDICATOR
SI3010A
24
Printing Outlet by pressing “ Print Key”
F48 ● 0 Printing Outlet No. 1
RE ZERO CALIBRATION
● 0 Re Zero Calibration Impossible F49
1 Re Zero Calibration Possibility
NEAR ZERO(EMPTY) BAND
F80 XXX
Indicator will read “ Zero” (empty) within entered limit. Enter weight by
numeric keys.
EX) 000 : When “ 0” display, Near Zero Relay output.
010 : When “ 10” or less, Near Zero Relay output
Under Limit Mode ( under Relay-Out Installed)
F81 XXX
Relay Output(Option) installed condition, user input Under-Limit Mode
※“ F11” : “ 02” setting : External Input by “ HOLD” Key
Without Relay Output : Code value can be used in case of Print
※Please make sure to press “ RESET” key to be memorized of new Function,
Otherwise,
Upper Limit Mode (under Relay Out Installed)
F82 XXX
Relay Output (Option) installed condition, user input Upper-Limit Mode
※“ F11” : “ 02” setting, External Input by “ HOLD” Key
※Please make sure to press “ RESET” key to be memorized of new Function,
Otherwise,
Calibration Span Constant Value
F89 Under “ SET-UP” mode, input number 89 by , Key, then press Key,
Calibration Span Constant Value display.
Date Set
F90 Enter new date by , keys and press key.
Time Set
F91 Enter new time by , keys and press key.
WEIGHING INDICATOR
SI3010A
25
Chapter 8. INTERFACE
8-1 RS-232 Serial Interface
RS-232C Interface is the system that transmit the signal by Voltage Volume and is
sensitive to the Noise. so you must install AC Power Cable or Electric Wire separately
also the cable must be used with Shield Coax Cable.
Set-Up : F-Function(F30∼F35)
▶Signal Format
①Type : EIA-RS-232C
②Method : Half-Duplex, Full-Duplex, Asynchronous
③Baud-rate : 1200, 2400, 4800, 9600, 19200, 38400 (according to customer set)
④Data bit : 7 or 8(No, Parity)
⑤Stop bit : 1
⑥Parity bit : Even, Odd, No, Parity (according to customer set)
⑦Code : ASCII
1 +9V LSB
0 1 2 3 4 5
MSB
6
0 -9V
⑧ Data format
Data format1(standard)
, , K g CR LF
Header1 Header2 Data(8) unit
▶Header 1 (Data format 2,3 common)
- OL : OVER LOAD, UNDER LOAD
- ST : display stable
- US : display unstable
▶Header 2 (Data format 2,3 common)
- NT : NETWEIGHT
- GS : GROSS WEIGHT
▶Numeric Data (Data format 2,3 common)
- 2B(H): "+"PLUS
- 2D(H): "-"MINUS
- 2O(H): " "SPACE
- 2E(H): "."Decimal point
▶UNIT (Data format 2,3 common)
- Kg - t - g
Data bit Start bit Parity bit
Stop bit
WEIGHING INDICATOR
SI3010A
26
Data format2(CAS format)
, , , Data(8) K g CR LF
Header1 Header2 I/D no. Lamp Blank
▶ID set-up : refer to F34
▶Lamp : ON or OFF condition
Data format3 (time format)
, , Data(8) K g CR LF
Header1 Header2 hour min sec Unit
▶hour , min , sec : 24 hours standard
▶PC (Personal Computer) connection
▶RS-232C Circuit
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
1 stable 1 Hold Print Gross Weight Tare Zero
2: RxD TxD : 3
3: TxD RxD : 2
5: SG SG : 5
2 : RxD
3 : TxD
5 : SG
2
3
5
WEIGHING INDICATOR
SI3010A
27
8-2 Current Loop Interface
Current Loop System is more safety for electric Noise rather than RS-232C.(approx.100M)
▶Transmission Mode
same to RS232C
▶Signal Format
same to RS232C
▶Data Format
same to RS232C
▶ Diagram for connection status to external devise(EX :RMOTE DISPLAY)
▶ Current Loop Circuit Schematic
1 20mA
0 0mA
Remote Display
SE 6005
SE 6105
SE 6300
Indicator
6 : RxD TxD : 8
7 : RxD TxD : 9
9 TxD 8 7 RxD 6
+5V
+5V
+5V
+12V +5V
WEIGHING INDICATOR
SI3010A
28
8-3 Serial Interface Command mode
▶ COMMAND MODE
P.C SI 3010A Command Response from SI 3010A
“ I” Time Data Transfer Time Data(8byte), 12:10:21
31h 32h 2Eh 31h 30h 2Eh 32h 31h
“ A” Date Data Transfer Date Data(8byte), 06.11.18
30h 36h 2Eh 31h 31h 2Eh 31h 38h
“ R” Current Weight Data
Transfer
Current Weight(8byte), 1.000kg
ST,NT,+30h 30h 31h 2Eh 30h 30h
30h
“ T” Tare Reset Tare will be reset
“ Z” “ Zero” Setting Zero will be set
“ H” “ Hold” Setting Hold will be set
“ C” “ Hold” Reset Hold will be reset
“ S” “ Sub Total” Request Sub Total data will be transfer
“ X” “ Sub Total” Delete Sub Total data will be deleted
WEIGHING INDICATOR
SI3010A
29
▶ COMMAND MODE Example
1. Time Data request (Current time is 10hour 45min.10sec.) - P.C Command : 49H
- SI 3010A Response : 31h 30h 2Eh 34h 35h 2Eh 31h 30h (8byte)
2. Date Data request (Current Date is 2006.11.18)
- P.C Command : 41h
- SI 3010A Response : 30h 36h 2Eh 31h 31h 2Eh 31h 38h (8byte)
3. Current Weight value request (Current weight is 1.000kg)
- P.C Command : 52h
- SI 3010A Response
F35-00 setting : ST,NT,+0001.000kg
53h 54h 2Ch 4Eh 54h 2Ch 2Bh 30h 30h 30h 31h 2Eh 30h 30h 30h 4Bh 47H
F35-01 setting : ST,NT,1(ID No.),6(Steady),0001.000kg
53h 54h 2Ch 4Eh 54h 2Ch 31h 36h 2Ch 30h 30h 30h 31h 2Eh 30h 30h 30h 4Bh 47H
F35-02 setting : ST,NT,091010 0001.000kg
53h 54h 2Ch 4Eh 54h 2Ch 30h 39h 31h 30h 31h 30h 30h 30h 30h 31h 2Eh 30h 30h 30h
4Bh 47H
F35-03 setting : Transfer as same format like Print(Refer Page 30.)
4. Tare Setting/Reset
- P.C Command : 54h
- SI 3010A Response : ACK(06h) or NAK(15h)
※ After setting “ TARE” , the weight is under minus(-), then “ TARE” set will be work.
5. Zero Setting
- P.C Command : 5Ah
- SI 3010A Response : ACK(06h) or NAK(15h)
6. Hold Setting
- P.C Command : 48h
- SI 3010A Response : ACK(06h) or NAK(15h)
7. Hold Reset
- P.C Command : 43h
- SI 3010A Response : ACK(06h) or NAK(15h)
8. Sub-Total Data Request
- P.C Command : 53h
- SI 3010A Response : ACK(06h) or NAK(15h)
9. Sub-Total Data Delete
- P.C Command : 58h
- SI 3010A Response : ACK(06h) or NAK(15h)
WEIGHING INDICATOR
SI3010A
30
8-4 OPTION 1(RELAY-OUT)
Limit Mode (① COM ② LOW ③ HI)
ex) Under condition of LOW value - F81 : 50 ,HI value - F82 : 100
When the products weigh 50 ㎏ or more, LOW Relay(1 ea) output,
When 100 ㎏ or more, LOW & HI Relay(2 ea ) output.
8-5. Printing Format
Single Print Format Continuous Print Format Sub-Total / Sub-Total delete
LOW
HI OFF
OFF
ON
ON
0Kg 50Kg 100Kg
WEIGHING INDICATOR
SI3010A
31
WEIGHING INDICATOR
SI3010A
32
QUALITY CERTIFICATE
SEWHACNM.CO.LTD
When SI-3010A has some problem within
warrantee period, we will replace as a new one
or fix the item under following warrantee clause.
Authorized
Signature
Srial No
Customer
Address
Purchase
date
YY MM DD
Warrantee Clause
1. Warrantee condition and Validity
We will take responsibility for the SI-3010A mal-function under/during normal operation for
one(1) year from the delivery date
2. Warrantee exceptions
We can not warrantee the malfunction or broken caused by following reasons.
- Malfunction or broken caused by modification or fix the product with own intention,
Without any approval from the Head office
- Malfunction or broken caused by operator’ s careless
- Distributed from unauthorized dealer / distributor
- Malfunction or broken caused by not following operating caution, mentioned on the manual
- Malfunction or broken by Forth majeure, like fire, flood.
- Without presentation of Quality Certification
2. Other Clause
If there is no Authorized Stamp on the certification, This certification has no effect ion.
WEIGHING INDICATOR
SI3010A
33
S E W H A C N M C O ., L T D
#310, Kolon Techno Valley, 60-4, Kasan-Dong, Keumcheon-Ku, 153-801 Korea Tel : (82 – 2)868 - 0701 Fax : (82 – 2) 868 - 0705
http://www.sewhacnm.co.kr
E-mail : [email protected]