4
New Publication ©1989 S&C ELECTRIC COMPANY PHOTO SHEET 911-705 Page 1 of 4 October 16, 1989 S&C Cypoxy® Insulators Station Post Insulators Indoor and Outdoor Distribution 4.8 kV through 34.5 kV The newly constructed substation pictured below, located in the southwestern United States, features the exclusive use of S&C’s Cypoxy station post insulators for bus support on the 25-kV secondary buswork grid. The instal- lation, in addition, features an extensive selection of S&C switch and fuse products supplied with Cypoxy station post insulators—including thirty-nine S&C Loadbuster Disconnects, four S&C SMD-20 Power Fuses, three S&C Regulator Bypass Switches, and an integer style S&C Alduti-Rupter Switch. All together, the substation includes one hundred forty-two Cypoxy station post insulators. The Decision to Adopt Cypoxy A number of factors contributed to this electric utility’s decision to construct a nearly all Cypoxy substation. The trim profile and aesthetics of S&C Cypoxy insulators, coupled with the shorter lead time relative to porcelain insulators played an important role in the selection of Cypoxy. However, of even greater importance were the outstanding electrical and mechanical-strength character- istics of Cypoxy insulators. Figure 1. Distribution substation in southwestern United States featuring more than one hundred forty Cypoxy station post insulators for apparatus and bus-support applications. Cypoxy Station Post Insulators Set a New Standard in Substation High-Voltage Insulation

Set a New Standard in Substation High-Voltage Insulation

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Set a New Standard in Substation High-Voltage Insulation

New Publication ©1989

S&C ELECTRIC COMPANY

PHOTO SHEET 911-705Page 1 of 4

October 16, 1989

S&C Cypoxy® Insulators Station Post InsulatorsIndoor and Outdoor Distribution4.8 kV through 34.5 kV

The newly constructed substation pictured below, locatedin the southwestern United States, features the exclusiveuse of S&C’s Cypoxy station post insulators for bussupport on the 25-kV secondary buswork grid. The instal-lation, in addition, features an extensive selection of S&Cswitch and fuse products supplied with Cypoxy stationpost insulators—including thirty-nine S&C LoadbusterDisconnects, four S&C SMD-20 Power Fuses, three S&CRegulator Bypass Switches, and an integer style S&CAlduti-Rupter Switch. All together, the substationincludes one hundred forty-two Cypoxy station postinsulators.

The Decision to Adopt CypoxyA number of factors contributed to this electric utility’sdecision to construct a nearly all Cypoxy substation. Thetrim profile and aesthetics of S&C Cypoxy insulators,coupled with the shorter lead time relative to porcelaininsulators played an important role in the selection ofCypoxy. However, of even greater importance were theoutstanding electrical and mechanical-strength character-istics of Cypoxy insulators.

Figure 1. Distribution substation in southwestern United States featuring more than one hundred forty Cypoxy station postinsulators for apparatus and bus-support applications.

Cypoxy Station Post InsulatorsSet a New Standard in Substation High-Voltage Insulation

Page 2: Set a New Standard in Substation High-Voltage Insulation

S&C Cypoxy® Insulators Station Post InsulatorsIndoor and Outdoor Distribution4.8 kV through 34.5 kV

The Cypoxy AdvantageS&C Cypoxy insulators are of molded construction, incor-porating a uniquely formulated cycloaliphatic epoxy resinespecially tailored to provide the electrical and mechani-cal-strength characteristics required of high-voltage insu-lators. Full-scale tests, including exhaustive outdoor test-ing at desert and seacoast test facilities that press thelimit in ultraviolet radiation and salt-spray exposure foran insulator, document the outstanding performance ofCypoxy insulators across a broad range of environments.And, verification of Cypoxy-insulator performance is fur-ther augmented by more than 15 years’ actual experiencewith Cypoxy insulators applied worldwide. In addition tothese performance characteristics, S&C Cypoxy stationpost insulators are electrically and mechanically inter-changeable with porcelain station post insulators—andthey meet or exceed the electrical and mechanical-strength ratings established in ANSI Standard C29.9(1983) for porcelain standard-strength insulators.

Other advantages of Cypoxy station post insulatorsinclude a light-weight design that is approximately onehalf the weight of comparable porcelain insulators . . . butwith even greater dry arcing and leakage distances.

S&C Cypoxy insulators are also formulated to resistdamage from power arcs such as may result from bridgingby a snake or other animal. Laboratory tests documentthe ability of Cypoxy insulators to withstand power arcsat currents to 25,000 amperes RMS symmetrical—withoutdamage—and to maintain rated electrical capabilitieswithout any need for post-arc cleanup. Porcelain insula-tors may be damaged by thermal shock and requirereplacement in the event of a high-current arc across theinsulator skirts.

And finally, Cypoxy insulators are homogeneous anddo not include a surface glaze. As a consequence, Cypoxyinsulators are tougher than porcelain with regard tomechanical shock. And even if a Cypoxy insulator shouldbe damaged, for example, by loss of a skirt due to vandal-

Figure 2. . . . another view of substation showing the extensive application of S&C’s Cypoxy station post insulators.

911-705 PHOTO SHEETPage 2 of 4October 16, 1989

Page 3: Set a New Standard in Substation High-Voltage Insulation

ism, the insulator will retain rated capabilities due to itshomogeneous construction. Porcelain insulators may suf-fer substantial reductions in strength as a result of dam-age to the glaze or to the insulator skirts.

Field- and Test-Proven PerformanceS&C has been engaged in the production of Cypoxy insu-lators for more than 15 years . . . with more than 2¹⁄₄ mil-lion insulator units shipped in that period. Extensive real-time and accelerated-life testing at desert, seacoast, andurban installations—plus long-term application in actualservice—confirm Cypoxy’s reliability for outdoor applica-tions.

Cypoxy insulators offer significant advantages in termsof cost, capabilities, and aesthetics that can be providedwith a wide selection of S&C distribution switch and fuseproducts. For more information concerning S&C Cypoxy

insulators, or products furnished with Cypoxy insulators,consult your nearest S&C Sales Office.

Figure 3. Cypoxy station post insulator rated 34.5 kV.

PHOTO SHEET 911-705Page 3 of 4

October 16, 1989

Page 4: Set a New Standard in Substation High-Voltage Insulation

S&C Cypoxy® Insulators Station Post InsulatorsIndoor and Outdoor Distribution4.8 kV through 34.5 kV

S&C ELECTRIC COMPANY

911-705 PHOTO SHEETPage 4 of 4October 16, 1989

Prin

ted

in U

.S.A

.

The versatility of Cypoxy . . .

. . . for switches. . . . for fuse mountings and bus support.

. . . for disconnects.